VX-2200 SERIES OPERATING MANUAL VERTEX STANDARD CO., LTD. VERTEX STANDARD YAESU EUROPE B.V. YAESU UK LTD. VERTEX STANDARD HK LTD.

Similar documents
VX-7200 OPERATING MANUAL APCO P25/FM TRANSCEIVER. (Tentative) VERTEX STANDARD CO., LTD. VERTEX STANDARD YAESU EUROPE B.V. YAESU UK LTD.

VX-3200 VX-3200 OPERATING MANUAL

VX-4200 SERIES BL-4200 OPERATING MANUAL VERTEX STANDARD CO., LTD. VERTEX STANDARD YAESU EUROPE B.V. YAESU UK LTD. VERTEX STANDARD HK LTD.

VX-2200E SERIES OPERATING MANUAL. VERTEX STANDARD CO., LTD Nakameguro, Meguro-Ku, Tokyo , Japan

VX-5500 OPERATING MANUAL

RMV25 / RMV50 RMU25 / RMU45

VX-920 OPERATING MANUAL

VX-900. Operating Manual

VX-450 SERIES OPERATING MANUAL

VX-4100E/4200ESERIES. VHF/UHF Mobile Radios

VX-5500 Series Low Band/VHF/UHF Mobile Radios

VX-820/-870 SERIES OPERATING MANUAL

VX-P820 Series Operating Manual. 16-Key Version 4-Key Version Non-LCD Version Vertex Standard LMR, Inc.

SECTION III OPERATION

VX-450 Series Operating Manual

Operating Manual A B C D. Vertex Standard LMR, Inc.

MobileRadio. Owner'sManual

INSTRUCTION MANUAL VHF FM TRANSCEIVER TK-6110 B (K,K2)

ic-f1020 ic-f2020 INSTRUCTION MANUAL VHF LAND MOBILE RADIO UHF LAND MOBILE RADIO

VXR-9000 RACK MOUNT REPEATER VXR-9000 FM REPEATER OPERATING MANUAL

Operating Manual Reprint

Operating Guide SMH 1525DT SMU 4525KT Technology Drive West Melbourne, FL RELM Wireless Corporation. All Rights Reserved CC OG 23

GM350 User Guide. GM350 User Guide. Safety Information. English

User Manual. Specifications...3. Control and Operation Microphone...8. Installation...9. Installation of Main Unit...9

VX-4100/4200SERIES. VHF/UHF Mobile Radios

OPERATING MANUAL Series. FM Portable Radio. Intrinsically-Safe SMARTNET, SmartZone Conventional

DC-1122 Compact 5W UHF CB Radio

INSTRUCTION MANUAL VHF TRANSCEIVER. if111 if121 UHF TRANSCEIVER. if211 if221

Content. Maintenance. Features ENGLISH. 1 transceiver 1 antenna 1 battery pack 1 belt clip 1 fast desktop charger User manual

INSTRUCTION MANUAL VHF TRANSCEIVER. if110s UHF TRANSCEIVER. if210s

TX4400 UHF CB RADIO INSTRUCTION MANUAL TX4400 INSTRUCTION MANUAL PAGE 1

INSTRUCTION MANUAL VHF TRANSCEIVER. if111 if121 UHF TRANSCEIVER. if211 if221

FTM-3100R/E. Advance Manual VHF FM TRANSCEIVER DIAL VOL

SUMMIT DM MULTI-NET MOBILE RADIO OPERATING MANUAL

SMH250D/SMU250K User s Guide

INSTRUCTION MANUAL VHF FM TRANSCEIVER TK-7100 UHF FM TRANSCEIVER TK-8100 B (K,M,M2)

GM950 User Guide. GM950 User Guide. Safety Information. English

RACK MOUNT REPEATER VXR Vertex Standard LMR, Inc. VXR-9000 FM REPEATER OPERATING MANUAL

98xx LOW TIER LTR /CONVENTIONAL OPERATING MANUAL

INSTRUCTION MANUAL VHF FM TRANSCEIVER TK-7102H UHF FM TRANSCEIVER TK-8102H KENWOOD CORPORATION B (M)

MOTOROLA COMMERCIAL SERIES BASIC USER GUIDE CM140 & CM160

VX-510 OPERATING MANUAL. VHF Hand-Held Portable Land Mobile Transceiver VERTEX STANDARD CO., LTD. VERTEX STANDARD YAESU UK LTD.

TLKR T60 OWNER'S MANUAL EN DE FR IT ES PR NL DA NO TU PL SV RU

UHF CB Transceiver VX-4600CB. Vertex Standard LMR, Inc.

Midland 248XL I NSTRUCTION GUI DE

PROFESSIONAL DIGITAL TWO-WAY RADIO SYSTEM MOTOTRBO DP 3600/DP 3601 DISPLAY PORTABLE QUICK REFERENCE GUIDE

UNIDEN uh088sx CB RADIO

Instruction Manual PMR-101TX. Private Mobile Radio. TTI Tech. 446MHz, 8 Channels

Midland Syn-Tech III P25 Mobile Radio

Cat. No OWNER S MANUAL. HTX-212 Two-Meter Mobile Transceiver. Please read before using this transceiver.

INSTRUCTION MANUAL VHF FM TRANSCEIVER TK-2206 UHF FM TRANSCEIVER TK-3206 B (M,M3 )

INSTRUCTION MANUAL VHF MOBILE TRANSCEIVERS. if5120d. Series UHF MOBILE TRANSCEIVERS. if6120d. Series

TWO-WAY RADIO. Þ ß Ô ² ú RPV516/RPU416. Owner's Manual

LBI-38795A. Mobile Communications AEGIS EDACS M-PA SYSTEM MODEL PORTABLE RADIO. Operator s Manual

i410pro ADVANCED MANUAL UHF CB TRANSCEIVER INTRODUCTION 1 ACCESSORIES AND INSTALLATION 2 BASIC OPERATION 3 SET MODE 4 REPEATER OPERATION 5 SCAN

VHF Transceiver AR6201

EVX Operating Manual

Rack Mount Repeater VXR-9000E. Operating Manual. Vertex Standard LMR, Inc.

VX-4000 SERIES. VHF/UHF Mobile Radios

GETTING STARTED. Radio layout. LCD display with icons

Introduction Mechanical radio operation... 12

OWNER S MANUAL FM HANDHELD TRANSCEIVER

TABLE OF CONTENTS NOTES: Features... Inside Front Cover. FCC Requirements...4. Safety Precautions...4

YCE13. Dealer PC Programming Software Reference Manual. Attention!

Function Key Settings THE TAIT ORCA 5000 CORPORATE HEAD OFFICE NEW ZEALAND. Tait Electronics Ltd CANADA. P O Box 1645, Christchurch

HR MHZ AM-FM AMATEUR RADIO HF TRANSCEIVER OWNER'S MANUAL. Content of the packaging

Commercial Series. CP140 Portable Radio. User Guide

PMR446 Radio Instruction Manual

PROFESSIONAL DIGITAL TWO-WAY RADIO SYSTEM. MOTOTRBO XiR M8220/ XiR M8228 NUMERIC DISPLAY MOBILE USER GUIDE

Greaval GV-8S. User Manual

Commercial Series CM160

FTV-1000 Operating Manual

PROFESSIONAL DIGITAL TWO-WAY RADIO MOTOTRBO DM4400/DM4401/DM4400e/DM4401e NUMERIC DISPLAY MOBILE USER GUIDE. es-es

FT-991. (WIRES-X Edition)

OPERATING GUIDE VHF DIGITAL TRANSCEIVERS. if1000d. series UHF DIGITAL TRANSCEIVERS. if2000d series. The photo shows the VHF transceiver.

Commercial Series CM360

TK-D740 TK-D740H TK-D740HV TK-D840 TK-D840H TK-D840HU

MXT100. GMRS Radio OWNER S MANUAL. midlandusa.com

BASIC USER GUIDE BASIC USER GUIDE CONTENTS. GeneralInformation... 2

Explorer 725 / 705. VHF Marine Radio Quickstart Guide.

OWNER S MANUAL

OPERATING GUIDE VHF TRANSCEIVER. Iç-G88

Pair of PMR446 Two-Way Personal Radios Model: TP391

User Guide Oricom UHF Channel UHF CB Radio

if30gt/gs if40gt/gs INSTRUCTION MANUAL VHF TRANSCEIVER UHF TRANSCEIVER

TX3420 REMOTE MOUNT UHF RADIO

FEATURE FUNCTION BENEFIT. The IC-F1721D/F1821D series comes in 2 styles: the simple version and the 10-key version

User manual AWR-8000 / AWR Advanced Wireless Communications

TH-78A 144/430MHz FM Dual Bander TH-78E INSTRUCTION MANUAL. 144/430 MHz FM Dual Bander 144/440 MHz FM Dual Bander KENWOOD CORPORATION

INSTRUCTION MANUAL VHF TRANSCEIVER. if110 UHF TRANSCEIVER. if210

INSTRUCTION MANUAL TX3400 UHF TRANSCEIVER

BCH-270 Owner s Manual

INSTRUCTION MANUAL FM HANDHELD TRANSCEIVER

DJ-MD5 PC Software Guidance

User s Guide. Olympian Series. 8/32/128 Channel VHF-FM Mobile Transceiver 8/32/128 Channel UHF-FM Mobile Transceiver.

BX SERIES HANDHELD RADIOS COMMERCIAL INSTRUCTION MANUAL BX SERIES HANDHELD INSTRUCTION MANUAL PAGE 1. Instruction manual includes models:

9/14/2017. APX 4000 Portable Radio. Before You Begin. APX 4000: Introduction. Rensselaer County Bureau of Public Safety 800 MHz Radio User Training

THANK YOU! MODELS COVERED IN THIS MANUAL

i4088a INSTRUCTION MANUAL FRS UHF FM TRANSCEIVER

GM600 User Guide. GM600 User Guide. English. Contents

Transcription:

VX-2200 SERIES OPERATING MANUAL P1 P2 P3 P4 VERTEX STANDARD CO., LTD. 4-8-8 Nakameguro, Meguro-Ku, Tokyo 153-8644, Japan VERTEX STANDARD US Headquarters 10900 Walker Street, Cypress, CA 90630, U.S.A. YAESU EUROPE B.V. P.O. Box 75525, 1118 ZN Schiphol, The Netherlands YAESU UK LTD. Unit 12, Sun Valley Business Park, Winnall Close Winchester, Hampshire, SO23 0LB, U.K. VERTEX STANDARD HK LTD. Unit 5, 20/F., Seaview Centre, 139-141 Hoi Bun Road, Kwun Tong, Kowloon, Hong Kong

Congratulations! You now have at your fingertips a valuable communications tool: a VERTEX STAN- DARD two-way radio! Rugged, reliable and easy to use, your VERTEX STANDARD radio will keep you in constant touch with your colleagues for years to come, with negligible maintenance downtime. Please take a few minutes to read this manual carefully. The information presented here will allow you to derive maximum performance from your radio, in case questions arise later on. We re glad you joined the VERTEX STANDARD team. Call on us anytime, because communications is our business. Let us help you get your message across. NOTICE! There are no owner-serviceable parts inside the transceiver. All service jobs must be referred to an authorized VERTEX STANDARD Service Representative. Consult your Authorized VERTEX STANDARD Dealer for installation of optional accessories. SAFETY/WARNING INFORMATION WARNING - DO NOT operate the VX-2200 radio when any person(s) (bystanders) outside the vehicle are within the distances shown in the chart at the bottom of this section. Safety Training information: Antennas used for this transmitter must not exceed an antenna gain of 0 dbd. The radio must be used in vehicle-mount configurations with a maximum operating duty factor not exceeding 50 %, in typical Push-to-Talk configurations. This radio is restricted to occupational use, work related operations only where the radio operator must have the knowledge to control the exposure conditions of its passengers and bystanders by maintaining the minimum separation distance shown below. Failure to observe these restrictions will result in exceeding the FCC RF exposure limits. Antenna Installation: For rear deck trunk installation, the antenna must be located at least the following distance away from rear-seat passengers in order to comply with the FCC RF exposure requirements. For roof top installations, the antenna must be placed in the center of the roof. Unsafe Radiation Distance

INTRODUCTION P1 P2 P3 P4 The VX-2200 Series are full-featured FM transceivers designed for flexible mobile and base station business communications in the VHF or UHF Land Mobile bands. These transceiver are designed for reliable business communications in a wide variety of applications with a wide range of operating capability provided by their leading-edge design. The 128-channel memories can each be programmed with a 8-character channel name. Important channel frequency data is stored in EEPROM and flash memory on the CPU, and is easily programmable by dealers using a personal computer and the VER- TEX STANDARD VPL-1 Programming Cable and CE82 Software. The pages which follow will detail the many advanced features provided on the VX- 2200 Series transceiver. After reading this manual, you may wish to consult with your Network Administrator regarding precise details of the configuration of this equipment for use in your application. For North American Users Regarding 406 MHz Guard Band The U.S. Coast Guard and National Oceanographic and Atmospheric Administration have requested the cooperation of the U.S. Federal Communications Commission in preserving the integrity of the protected frequency range 406.0 to 406.1 MHz, which is reserved for use by distress beacons. Do not attempt to program this apparatus, under any circumstances, for operation in the frequency range 406.0-406.1 MHz if the apparatus is to be used in or near North America. VX-2200 SERIES OPERATING MANUAL 1

Front Panel CONTROLS & CONNECTORS Important! - All buttons located on the Front Panel are Programmable Function (PF) Buttons, configured according to your network requirements and programmed by your VERTEX STANDARD dealer. The instructions below describe a typicallyconfigured radio. 16 5 4 P1 P2 P3 P4 2 3 1 VOL/PWR Knob Turn this control clockwise to turn the radio on and to increase the volume. Turn it counterclockwise into the click-stop to turn the radio off. 2 Microphone Jack Connect the microphone plug to this jack. 3 [ P1] - [P1] Buttons (Programmable Function Buttons) These buttons can be set up for special applications, such as High/Low power selection, Monitor, Talk-Around, etc., as determined by your network requirements and programmed by your VERTEX STANDARD dealer. 4 [ ]/[ ] Buttons (Programmable Function Buttons) Pressing either button changes the current channel (and displayed channel number or name). Holding in either button for more than 1.5 second causes the radio to begin stepping (repeatedly) upward or downward through the channels. 2 VX-2200 SERIES OPERATING MANUAL

CONTROLS & CONNECTORS 5 LCD (Liquid Crystal Display) The display includes a 8-character alpha-numeric section showing Channel name tags/identity information and error messages, and an upper icon row displaying feature status (see below). 6 BUSY/TX Indicator Indicates transceiver s Transmit/Receive Status Steady Red: Transmitting in progress Steady Green: Signaling Off Blinking Green: Busy Channel/Squelch Off Dual Watch is activated Low Transmt Power Mode ON AUX A Port is activated Encryption is enabled : Scan is activated : Priority Scan is activated Call indicator Receiver Monitor Talk-Around is enabled Priority Channel Channel Group Number RSSI Indicator (four steps) 8 Character Alpha-numeric Display Group Scan is enabled VX-2200 SERIES OPERATING MANUAL 3

Rear Panel CONTROLS & CONNECTORS 1 2 4 3 1 13.6V DC Cable Pigtail with Connector The supplied DC power cable must be connected to this 2-pin connector. Use only the supplied fused cable, extended if necessary, for power connection. 2 Antenna Socket The 50-Ohm coaxial feedline to the antenna must be connected here, using a type-m (PL-259) plug. 3 D-Sub 15-Pin Accessory Connector External TX audio line input, PTT (Push To Talk), Squelch, and external RX audio line output signals may be obtained from this connector for use with accessories such as data transmission/reception modems, and external Channel control input etc. 4 External Speaker Jack An external loudspeaker may be connected to this 2-contact, 3.5-mm mini-phone jack. Caution: Do not connect either wire of this line to ground, and be certain that the speaker has adequate capability to handle the audio output (12 W) from the radio. 4 VX-2200 SERIES OPERATING MANUAL

BASIC OPERATION OF THE TRANSCEIVER Important! - Before turning on the radio the first time, confirm that the power connections have been made correctly and that a proper antenna is connected to the antenna jack. Switching Power ON/OFF Turn the VOL/PWR knob turn on the radio. The display will become illuminated. Press the [ ]/[ ] button to choose the desired operating channel. A channel name will appear on the display. If you want to select an operating channel from a different group, press the PF (Programmable Function) button which is programmed to the Group Up/Down feature to select the group you want before selecting the operating channel. See page 7 for more information on the Programmable Function keys. Setting the Volume Turn the VOL/PWR knob clockwise to increase the volume, and counterclockwise to decrease it. Transmitting To transmit, monitor the channel and make sure it is clear. THIS IS AN FCC REQUIRMENT! Press the PF button which is programmed to the Monitor feature to listen for channel activity. When receiving a call, transmit only after the incoming call ends. The radio cannot receive a call and transmit simultaneously. Press the PTT switch. If the channel is clear, the BUSY/TX indicator will glow red. The radio is now transmitting. While holding in the PTT switch, speak across the face of the microphone in a clear and normal voice. For best transmission, hold the microphone about 1-1/2 to 2 inches away from your mouth. Release the PTT switch to receive. If the Busy Channel Lockout feature has been programmed on a channel, the radio will not transmit when a carrier is present. Instead, the radio will generate a short beep three times and indicate * ERROR * on the display. Release the PTT switch and wait for the channel to be clear of activity. If CTCSS or Digital Coded Squelch (DCS) Lockout has been programmed on a channel, the radio can transmit only when there is no carrier being received or when the carrier being received includes the correct CTCSS tone or DCS code. VX-2200 SERIES OPERATING MANUAL 5

Automatic Time-Out Timer If the selected channel has been programmed for automatic time-out, you must limit the length of each transmission. While transmitting, a beep will sound 10 seconds before time-out. Another beep will sound just before the deadline; the red TX indicator will disappear and transmission will cease soon thereafter. To resume transmitting, you must release the PTT switch and wait for the penalty timer to expire (if you press the PTT switch before this timer expires, the timer restarts, and you will have to wait another penalty period) Key Lock BASIC OPERATION OF THE TRANSCEIVER In order to prevent accidental frequency change or inadvertent transmission, various aspects of the VX-2200 s keys, and PTT switch, may be locked out. The precise lockout configuration may be configured using the User Set (Menu) mode. See page 16 for detail. To activate the Locking feature, press and hold in the [P4] key while turning the radio on. To disable the Locking feature, repeat this power-on procedure. 6 VX-2200 SERIES OPERATING MANUAL

ADVANCED OPERATION Programmable Function (PF) Buttons The VX-2200 Series includes seven Programmable Function (PF) Buttons. The PF button functions can be customized, via programming by your VERTEX STAN- DARD dealer, to meet your communications/network requirements. Some features may require the purchase and installation of optional internal accessories. The possible PF button programming features are illustrated below, and these functions are explained on the pages to follow. For further details, contact your VERTEX STANDARD dealer. For future reference, check the box next to the function that has been assigned to each PF button on your particular radio, and keep it handy. Function PF Button P1 P2 P3 P4 Function PF Button P1 P2 P3 P4 MONI SQL DIMMER Channel Up Channel Down Group Up Group Down SCAN DW (Dual Watch) Follow-Me SCAN Follow-Me DW LOW TA (Talk Around) TX SAVE Disable Encryption Disable Emergency CALL/RESET CALL 1 CALL 2 CALL 3 CALL 4 CALL 5 Code Up Code Down Code SET Speed Dial HOME Selectable Tone Public Address EXT. ACC1 EXT. ACC2 Direct CH#1 Direct CH#2 Direct CH#3 Direct CH#4 AF Min Vr SET : Requires optional unit VX-2200 SERIES OPERATING MANUAL 7

Description of Operating Functions MONITOR (MONI) Press the assigned programmable key to cancel CTCSS- and DCS-controlled squelch; the BUSY/TX indicator will glow green. Press and hold in this button for 1.5 seconds to hear background noise (unmute the audio); the BUSY/TX indicator will blink green. SQUELCH (SQL) ADVANCED OPERATION You can manually adjust the squelch level using this function: Press the assigned programmable key. A tone will sound, and the current squelch will level appears on the display. Press the [ ]/[ ] button to select the desired squelch level. Press this key again. A tone will sound, and the display will revert to the normal channel indication. DIMMER Press the assigned programmable key to select the brightness level of the display and key backlight. Available selections are four levels. CHANNEL UP/DOWN Press the assigned programmable key (generally the [ ]/[ ] button) to select a different channel within the current group. GROUP UP/DOWN Press the assigned programmable key to select a different group of channels. Once the desired Group is reached, press the Channel Up/Down key (generally the [ ]/ [ ] button) to select the desired channel within the selected Group. You may wish to have the Scanner pass through more than one Group during the scanning process (normally, scanning is performed within the current group only). To include the current Group in the scanning loop, press and hold in the assigned programmable key for one second. To remove a Group from Group Scan, press and hold in the assigned programmable key again for one second. Multi-Group Scanning is only possible if you are using the User Scan list. To edit the User Scan list, press and hold the assigned programmable key for one second to delete the current Memory Group from the Scanning. Alternatively, press and hold the assigned programmable key for one second to delete the Current Memory chan- 8 VX-2200 SERIES OPERATING MANUAL

ADVANCED OPERATION nel from the Scanning. When you delete a Group or channel, - SCAN Skip- will appear on the LCD for one second after pressing the assigned programmable key. To restore a particular channel to your scanning list, press and hold in the assigned programmable key again for one second; - SCAN Stop- will appear on the LCD for one second after pressing the assigned programmable key. CHANNEL SCAN (SCAN) The Scanning feature is used to monitor multiple channels programmed into the transceiver. While scanning, the transceiver will check each channel for the presence of a signal, and will stop on a channel if a signal is present. To activate scanning: Press the assigned programmable key to activate scanning on the current group. The scanner will search the programmed channels, looking for active ones; it will pause each time it finds a channel on which someone is speaking. Press the assigned programmable key again to disable scanning. Operation will revert to the programmed revert channel or activate the Group scanning when Multi-Group Scanning is enabled. Note: Your dealer may have programmed your radio to stay on one of the following channels if you press the PTT switch during the scanning pause: Current channel ( Talk Back ) Last Busy channel Priority channel Home channel Scan Start channel DUAL WATCH (DW) The Dual Watch feature is similar to the SCAN feature, except that only two channels are monitored: The current operating channel; and The Priority channel. To activate Dual Watch: Press the assigned programmable key. The scanner will search the two channels; it will pause each time it finds a channel on which someone is speaking. To stop Dual Watch: Press the assigned programmable key. Operation will revert to the Dual Watch Start channel. VX-2200 SERIES OPERATING MANUAL 9

FOLLOW-ME SCAN Follow-Me Scan feature checks a User-assigned Priority Channel regularly as you scan the other channels. Thus, if only Channels 1, 3, and 5 (of the 8 available channels) are designated for Scanning, the user may nonetheless assign Channel 2 as the User-assigned Priority Channel via the Follow-Me feature. To activate Follow-Me scanning, first select the channel you want to designate as the User-Assigned Priority Channel and press the assigned programmable key. Then press the Channel Up/Down key (generally the [ ]/[ ] button) to recall to the Scanning Start channel which has been programmed by your dealer to activate the scanner. When the scanner stops on an Active channel, the User-assigned Priority Channel will automatically be checked every few seconds; if activity is found on the User-assigned Priority Channel, the radio will switch between it and the Dealer-Assigned Priority Channel, if any. FOLLOW-ME DUAL WATCH (DW) To set up a Dual Watch frequency pair using the Follow-Me feature, select a channel using the Channel Up/Down key (generally the [ ]/[ ] button). Now press the assigned programmable key; pressing the assigned programmable key locks the current channel as the User-assigned Priority Channel. Now press the Channel Up/ Down key to select another channel (not the Scanning Start channel). Your radio will now switch back-and-forth between the currently-selected channel and the Userassigned Priority Channel. During Follow-Me scanning (after you have pressed the key), you can set up the Dual Watch feature by pressing the Channel Up/Down key to another channel. The radio will then scan back and forth between the original User-assigned Priority Channel and the newly-selected channel. The Priority Channel you have assigned (before pressing the key) will be retained in memory until you change it. LOW POWER (LOW) ADVANCED OPERATION Press the assigned programmable key to set the radio s transmitter to the Low Power mode, thus extending battery life. Press the key again to return to High Power operation when in difficult terrain. When the radio s transmitter is set to Low Power mode, the indicated on the display. icon will be 10 VX-2200 SERIES OPERATING MANUAL

TALK AROUND (TA) ADVANCED OPERATION Press the assigned programmable key to activate the Talk Around feature when you are operating on duplex channel systems (separate receive and transmit frequencies, utilizing a repeater station). The Talk Around feature allows you to bypass the repeater station and talk directly to a station that is nearby. This feature has no effect when you are operating on simplex channels, where the receive and transmit frequencies are already the same. When the TA function is activated, the icon will be indicated on the display. Note that your dealer may have mode provision for Talk Around channels by programming repeater and Talk Around frequencies on two adjacent channels. If so, the key may be used for one of the other Pre-Programmed Functions. ENCRYPTION DISABLE (OPTION) When the Voice Scrambler feature is enabled, press the assigned programmable key to toggle the voice encryption on and off. EMERGENCY The VX-2200 series include an Emergency feature which may be useful if you have someone monitoring on the same frequency as your transceiver s channel. Press the assigned programmable key to initiate an emergency call. For further details contact your VERTEX STANDARD dealer. CALL/RESET This feature, if enabled, allows the user to change the 3-digit Page Call code, used to call other similarly-equipped stations. Press the assigned programmable key, followed by the three digits representing the Page Call code of the station you wish to call. Three tones will be heard after the last key is pressed (the new code will now be transmitted). The receiver squelch of the other station will be opened, and you can begin communication. CALL 1 TO CALL 5 Press the assigned programmable key to send a 5-Tone sequential burst which is predefined. VX-2200 SERIES OPERATING MANUAL 11

CODE UP/DOWN Press the assigned programmable key to select a 5-Tone encode code from pre-defined encode list. CODE SET Press the assigned programmable key to change the 5-Tone encodeing digit. To change the tones, select the desired digit using the [P1]/[P2] keys, then change the number using the [ ]/[ ] keys. STATUS UP/DOWN Press the assigned programmable key to select a 5-Tone status code from the predefined status list. SPEED DIAL Your Dealer may have pre-programmed Auto-Dial telephone number memories into your radio. To dial a number, press the assigned programmable key, then press the microphone s numbered key corresponding to the Auto-Dial memory number list provided by your Dealer. The DTMF tones sent during the dialing sequence will be heard in the speaker. HOME CHANNEL (HOME) Press the assigned programmable key to recall the pre-defined Home group/channel. When you recall the Home group/channel, the H icon will appear on the LCD. SELECTABLE TONE ADVANCED OPERATION Press the assigned programmable key to select a sub-audible tone (CTCSS/DCS) from the pre-defined tone table. You can operate the indicated sub-audible tone in Selectable Tone mode. PUBLIC ADDRESS Press the assigned programmable key to use the transceiver as a PA amplifier. When you enable this function, a tone sounds and Public ADRS will appear on the display. The public address can be used even while scanning and receiving a call. EXT. ACC1 Press the assigned programmable key to toggle output port on 1 on and off. 12 VX-2200 SERIES OPERATING MANUAL

ADVANCED OPERATION EXT. ACC2 Press the assigned programmable key to toggle output port on 2 on and off. DIRECT CH#1 TO DIRECT CH#4 Press the assigned programmable key to recall the Dealer pre-programmed channel directly. AF MIN VR Press the assigned programmable key to reduce the audio output to the (lower) level programmed by your Dealer. SET Press the assigned programmable key to activate the User Set (Menu) Mode. VX-2200 SERIES OPERATING MANUAL 13

ADVANCED OPERATION ARTS (Auto Range Transpond System) This system is designed to inform you when you and another ARTS-equipped station are within communication range. During ARTS operation, when the radio receives an incoming ARTS signal, a short beep will sound, and In ( In Service ) will be displayed on the LCD for 2 seconds. If you move out of range for more than two minutes, your radio senses that no signal has been received; a short triple-beep will sound, and Out ( Out of Service ) will be displayed on the LCD for 2 seconds. If you subsequently move back into communication range, as soon as the other station transmits, a short beep will sound and In will be displayed again on the LCD for 2 seconds. DTMF Paging System (Requires the optional FVP-25 Encryption/DTMF Pager Unit) This system allows paging and selective calling, using DTMF tone sequences. When your radio is paged by a station bearing a tone sequence which matches yours, your radio s squelch will open and the alert will sound. The three-digit code of the station which paged you will be displayed on your radio s LCD. 14 VX-2200 SERIES OPERATING MANUAL

USER SET MODE The VX-2200 Series includes a User Set (Menu) Mode which allows the user to define or configure various settings, such as Squelch, Display contrast, etc. To activate the User Set (Menu) Mode: Press the programmable key assigned to the SET function. Select the User Set Mode item you wish to change using the [P1]/[P2] keys, then use the [ ]/[ ] keys to adjust the setting of the selected item. Press the [P1] or [P2] key to store the new configuration. Press the programmable key assigned to the SET function to exit to normal operation. DISPLAY DESCRIPTION 1 SCN List Select the User or Dealer Scan List. 2 BEEP Enables/Disables the Key Beeper. 3 BELL Enables/Disables the Bell function. (alert tone activated by incoming subaudible CTCSS/DCS tone) 4 Lighting Enables/Disables the BUSY/TX LED. 5 Lock Set the Control Key Lockout Cofiguration (Key/PTT/Key+PTT). 6 Group Select the desired Channel Group. 7 SCAN Engages/Disengages Scanning (same as the programmable [SCAN] key). 8DW Engages/Disengages Dual Watch (same as the programmable [DW] key). 9TA Engages/Disengages Talk Around (same as the programmable [TA] key). 10 Encrypt Enables/Disables the disabling the Encryption Unit temporarily. ENB: Enables the disabling the Encryption Unit. DIS: Disables the disabling the Encryption Unit. 11 AF MinVR Sets the minimum Audio Volume level. 12 Beep VR Sets the Beep Volume level. 13 Contrast Sets the LCD Contrast level. 14 Dimmer Sets the brightness of the backlighting of the key and LCD. VX-2200 SERIES OPERATING MANUAL 15

FVP-25 FVP-35 VTP-50 FP-1023A MLS-100 LF-1 MH-700D MH-67A8J MH-25A8J MD-11A8J VPL-1 OPTIONAL ACCESSORIES Encryption/DTMF Pager Unit Encryption Unit VX-Trunk Unit External Power Supply Mobile Loudspeaker (12 W Peak Power) Line Filter DTMF Back-lit Microphone Microphone Microphone Desktop Microphone Programming Kit Availability of accessories may vary; some accessories are supplied standard per local requirements, others may be unavailable in some regions. Check with your VERTEX STANDARD Dealer for changes to this list. 16 VX-2200 SERIES OPERATING MANUAL

Part 15.21: Changes or modifications to this device not expressly approved by Vertex Standard could void the user s authorization to operate this device.

Copyright 2006 VERTEX STANDARD CO., LTD. All rights reserved. No portion of this manual may be reproduced without the permission of VERTEX STANDARD CO., LTD. Printed in Japan E C 0 6 1 U 1 0 0