Report No.: HZ h/R1. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

Similar documents
Report No.: HZ b. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

Report No.: HZ a/R2. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

Report No.: HZ b. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

Report No.: HZ a/R2. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

Report No.: HZ c/R1. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

(Lumens) Stabilization Time CRI (K) (Light & Power) Table 1 Executive Data Summary

Report No.: HZ f. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

(Lumens) Stabilization Time CRI (K) (Light & Power) Table 1 Executive Data Summary

LM Test Report. for EiKO Global, LLC. 25W Floodlight Model: FLM-2C-N-U

LM Test Report. for Maxlite SK America Inc. 2*4 Retrofit Kits Model: RKT4514U5550DV

LM Test Report. for Maxlite Inc. LED Canopy Model: MLCAN20LED50

Report No.: HZ j. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

Report No.: HZ h. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

LM Test Report. for Maxlite SK America Inc. WALLPACK Model: MLSWP30LED50DS

Report No.: HZ w. Stabilization Time (Light & Power) CRI. Table 1: Executive Data Summary. Figure 1- Overview of the sample

LM Test Report. for. Philips (China) Investment Co., Ltd. InstantFit LEDtube Model:

LM Test Report. for Elec-Tech International Co.,Ltd. LED CEILING LIGHT Model: XX(XX: 01-10)

LM Test Report. for Elec-Tech International Co.,Ltd. LED CEILING LIGHT Model: XX(XX: 61-70)

LM Test Report. for Elec-Tech International Co.,Ltd. LED CEILING LIGHT Model: XX(XX: 01-10)

LM Test Report. for Elec-Tech International Co., Ltd. BR40 LAMP Model: XX(XX:01-10), WBR40L27S2A

Catalog Number UPC Number LED Spot Bullet Flood Light 42W 4204 Lumens White

LM Test Report. for Elec-Tech International Co.,Ltd. LED PAR30 Spot light Model: XX(XX:41-50)

Morris Products 53 Carey Road, Queensbury, NY 12804

Cat# LED Classic Large Wall-Pack

Catalog Number UPC Number LED Spot Bullet Flood Light 15W 1620 Lumens Bronze

Report No.: EASZE Page 2 of 14

Report No.: HZ k/R1. (Lumens) Stabilization Time CRI (K) (Light & Power) Table 1: Executive Data Summary

Report No.: HZ c

Report No.: HZ a. 60 mins Note. 4000K, frosted lens Table 1: Executive Data Summary

LM Test. for LED. Cabinet

Report No.: HZ d

L Test Report. LED TUBE 1odel: LED11.5WT8/48/850-PET-G7DR

LM Test Report. For. T8 LEDTUBE Model: LED9WT8 F/24/850K-G7D

57-100W-XXK-WPH12-SG W-40K-WPH12-SG W-57K-WPH12-SG

Test Report. Report No.: EED35I Page 1 of 10. Customer : EIKO GLOBAL LLC Address : W 84TH ST SHAWNEE, KS USA

Eternal Shine Technology Co.,Ltd. EST

LM Test Report. For KEYSTONE TECHNOLOGIES LLC. (Brand Name: KEYSTONE) 1390 Welsh Road North Wales, PA 19454

NVLAP LAB CODE LM Test Report. For. MaxLite Inc. (Brand Name: MaxLite) 12 York Ave West Caldwell NJ 07006

NVLAP LAB CODE LM Test Report. For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD. (Brand Name: GI LED LIGHTING)

TEST REPORT. Job No SHA Date: Apr 12,2017 REPORT NO SHA-006. TEST OF ONE LED Luminaire MODEL NO.

LM Test Report. For. GREEN LOGIC LED ELECTRICAL SUPPLY INC (Brand Name: GLLUSA) Shenfubao Industry Park, Bonded area, Futian District,Shenzhen

Photometric Test Report

LM Test Report. For FALKOR INDUSTRY INC. (Brand Name: Falkor Lighting) 5580 Bandini Blvd Bell,CA USA

LM Test Report. For FALKOR INDUSTRY INC. (Brand Name: Falkor Lighting) 5580 Bandini Blvd Bell,CA USA

71332 LED Dusk To Dawn (Area Light)

NVLAP LAB CODE LM Test Report. For EIKO GLOBAL, LLC W 84th St., Shawnee, KS

LM Test Report. For. Eternal Shine Technology Co.,Ltd. (Brand Name: EST) ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China

NVLAP LAB CODE LM Test Report. For SHENZHEN BONLD ELECTRONICS CO.,LTD. (Brand Name: BONLD)

LM Test Report. For. Builders Pack. ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China

NVLAP LAB CODE LM Test Report. For HOCAN GROUP CO LTD. (Brand Name: N/A)

NVLAP LAB CODE LM Test Report. Outdoor Non-Cutoff and Semi-Cutoff Wall-mounted Area Luminaires. Model name(s): WML-50W

NVLAP LAB CODE LM Test Report For. Outdoor Pole/Arm-mounted Area and Roadway Luminaires

REVOLUTION LIGHTING TECHNOLOGIES INC

NVLAP LAB CODE LM Test Report. Outdoor Full-Cutoff Wall-mounted Area Luminaires. Model name(s): LWA-50W

NVLAP LAB CODE LM Test Report. For GREEN LOGIC LED ELECTRICAL SUPPLY INC. Outdoor Full-Cutoff Wall-mounted Area Luminaire

NVLAP LAB CODE LM Test Report. Outdoor Non-Cutoff and Semi-Cutoff Wall-mounted Area Luminaires

NVLAP LAB CODE LM Test Report. For HOCAN GROUP CO LTD. (Brand Name: N/A)

NVLAP LAB CODE LM Test Report. For HOCAN GROUP CO LTD. (Brand Name: N/A)

NVLAP LAB CODE LM Test Report. Outdoor Full-Cutoff Wall-mounted Area Luminaires

IESNA LM79: 2008 Photometric Test Report

NVLAP LAB CODE LM Test Report. For BEYOND LED TECHNOLOGY Mountain Industrial Blvd. Suite A-1 Tucker, GA USA

NVLAP LAB CODE LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name: N/A) 188 S. Northwest Highway Cary, IL 60013

NVLAP LAB CODE LM Test Report. For MAXLITE,INC. (Brand Name: N/A) 12 YORK AVENUE WEST CALDWELL,NJ 07006

NVLAP LAB CODE LM Test Report. For. LED Waves, Inc st. Ave. Brooklyn, NY USA. Linear Retrofit Kits for 2x2 Luminaires

NVLAP LAB CODE LM Test Report. For ATG ELECTRONICS CORP. (Brand Name: N/A) th Street Rancho Cucamonga, CA 91730

LM Test Report. For. Eternal Shine Technology Co.,Ltd. (Brand Name: EST) ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China

LED Floodlight. RoHS. Model: inner box: L 17" X W 12.5" X H 9.33" 1PCS AC 50/60HZ. Input Voltage 0.85A MAX. Input Current 78 W.

LM Test Report. For. Revolution Lighting Technologies, Inc. (Brand Name: ) 2280 Ward Ave. Simi Valley, CA

LM Test Report

Cat# LED Wall-PACK

LM Test Report. For. Builders Pack. ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China

LM Test Report. For. Torshare Ltd. (Brand Name: TORSHARE)

NVLAP LAB CODE LM Test Report. For. Maxlite Inc. (Brand Name: ) 12 York Avenue, West Caldwell, NJ

TEST REPORT. Job No SHA Date: February 19, 2017 REPORT NO SHA-003

LM Test Report

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD. (Brand Name: THAILIGHT)

DRAFT. Approved Method: Electrical and Photometric. Measurements of Solid-State Lighting Products. LCTECH (Zhongshan) Testing Service Co.

LM Test Report. For. Eternal Shine Technology Co.,Ltd. (Brand Name: EST) ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China

Approved Method: Electrical and Photometric. Measurements of Solid-State Lighting Products

NVLAP LAB CODE LM Test Report. For. LED2 Lighting Group, Inc. (Brand Name: LED2) 600 Minnesota Ave, Kansas City, KS 66101

NVLAP LAB CODE LM Test Report. For. LED2 Lighting Group, Inc. (Brand Name: LED2) 600 Minnesota Ave, Kansas City, KS 66101

NVLAP LAB CODE LM Test Report. For. Shenzhen OKT Lighting Co.,LTD. (Brand Name: OKT LIGHTING)

NVLAP LAB CODE LM Test Report. For. Shenzhen OKT Lighting Co.,LTD. (Brand Name: OKT LIGHTING)

LM Test Report

IESNA LM79: 2008 Photometric Test Report

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MAXLED) 12 York Avenue West Caldwell, NJ

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD. (Brand Name: THAILIGHT)

Dark Sky Wallpack 50W. General ACD12 Aluminum Heat Sink High Light Transmittance Polycarbonate, Anti-UV and Fire Resistant Finish:

Approved Method: Electrical and Photometric. Measurements of Solid-State Lighting Products

ApprovedMethod: Electricaland Photometric. Measurements of Solid-State Lighting Products

IESNA LM79: 2008 Photometric Test Report

Approved Method: Electrical and Photometric Measurements of Solid-State Lighting Products

NVLAP LAB CODE LM Test Report. For. Maxlite INC. (Brand Name: Maxlite) 12 York Ave., West Caldwell, NJ 07006

NVLAP LAB CODE Energy Star Test Report. For. Shenzhen OKT Lighting Co.,LTD

LM Test Report

RoHS QPL ID # P9JSE2P8. Cat# Watts Trunion Mount. Model: master carton: L*W*Hmm 1PCS. EPA Rating 1.

Approved Method: Electrical and Photometric. Measurements of Solid-State Lighting Products

Address: IES LM Luminaire Description: Indoor High Bay Light Source: LGIT 5630 Ballast/Driver: VPL Overdrive L320HBL46DIM/50K

LM Test Report

QPL ID # PLG2YNJ831VZ

Transcription:

Test Summary Sample Tested: KT-PLED50-24-850-VDIM /G2 Luminous Efficacy (Lumens /Watt) Total Luminous Flux (Lumens) Power (Watts) Power Factor 117.9 6083.5 51.62 0.9926 CCT (K) CRI Stabilization Time (Light & Power) 4779 84.1 60 Table 1: Executive Data Summary Test specifications: Date of Receipt : May 28, 2018 Date of Test : Jun. 28, 2018 Test item : Total Luminous Flux, Luminous Distribution Intensity, Luminous Efficacy, Correlated Color Temperature, Color Rendering Index, Chromaticity Coordinate, Electrical parameters Reference Standard : IESNA LM-79-2008 Approved Method for the Electrical and Photometric Measurements of Solid-State Lighting Products Prepared by: Leading Testing Laboratories Page 2 of 13

TABLE OF CONTENT LM-79-08 Test Report... 1 Sample Photos... 4 TEST RESULTS... 5 Spectral Power Distribution... 6 Zonal Lumen Tabulation... 7 Luminous Intensity Distribution Plots... 9 Luminous Intensity Data... 10 EQUIPMENT LIST... 12 TEST METHODS... 12 Seasoning of SSL Product... 12 Goniophotometer Method... 12 Photometric and Electrical Measurements... 12 Color Characteristics Measurements... 13 Color Spatial Uniformity... 13 Prepared by: Leading Testing Laboratories Page 3 of 13

Sample Photos Overview of the sample Equipment Under Test (EUT) Name : LED Panel Light Model : KT-PLED50-24-850-VDIM /G2 Electrical Ratings : 120-277V, 50/60Hz Product Description : 5000K Prepared by: Leading Testing Laboratories Page 4 of 13

TEST RESULTS Test ambient temperature was 24.9. Base orientation was base up. Test was conducted without a dimmer in the circuit. The stabilization time of the sample was 60 minutes, and the total operating time including stabilization was 95 minutes. The photometric distance of Goniophotometer is 30 m. Luminous data was taken at 0.5 vertical intervals and 10.0 horizontal intervals. Parameter Result Special Color Rendering Indices Test Voltage (V) 120.0 277.0 R1 82 Voltage frequency (Hz) 60 60 R2 91 Test Current (A) 0.433 0.201 R3 95 Power Factor 0.9926 0.9175 R4 81 Test Power (W) 51.62 51.07 R5 82 THD A% 12.20 10.44 R6 86 Luminous Efficacy (lm/w) 117.9 119.2 R7 87 Total Luminous Flux (lm) 6083.5 6085.2 R8 68 Color Rendering Index (CRI) 84.1 R9 14 R9 14 R10 78 Correlated Color Temperature (CCT) (K) 4779 R11 80 Chromaticity (Chroma x, Chroma y) (0.3523, 0.3624) R12 58 Chromaticity (Chroma u, Chroma v) (0.2121, 0.3273) R13 85 Chromaticity (Chroma u, Chroma v ) (0.2121, 0.4909) R14 98 Duv 0.0026 Average Beam Angle ( ) 117.7 Center Beam Candle Power (cd) 1993 Spacing Criteria 1.31(0-180 )/ 1.28 (90-270 ) Zonal Lumens in the 0-60 Zone 76.74% Zonal Lumens in the 60-90 Zone 23.19% Zonal Lumens in the 90-120 Zone 0.03% Zonal Lumens in the 120-180 Zone 0.04% Table 2: Test data per Goniophotometer Method Note: According to CIE 1976 (u,v ) diagram, u = u = 4x/(-2x+12y+3), v = 3v/2 = 9y/(-2x+12y+3). Prepared by: Leading Testing Laboratories Page 5 of 13

Spectral Power Distribution Chart 1: Spectral Power Distribution Prepared by: Leading Testing Laboratories Page 6 of 13

Zonal Lumen Tabulation γ( ) Lumens % Total 0-10 188.878 3.10% 10-20 544.065 8.94% 20-30 833.711 13.70% 30-40 1021.238 16.79% 40-50 1080.579 17.76% 50-60 999.831 16.44% 60-70 787.525 12.95% 70-80 478.743 7.87% 80-90 144.314 2.37% 90-100 1.078 0.02% 100-110 0.414 0.01% 110-120 0.485 0.01% 120-130 0.534 0.01% 130-140 0.613 0.01% 140-150 0.6 0.01% 150-160 0.467 0.01% 160-170 0.312 0.01% 170-180 0.116 0.00% Total 6083.5 100% γ( ) Lumens % Total 0-60 4668.302 76.74% 60-90 1410.582 23.19% 0-90 6078.884 99.92% 90-180 4.619 0.08% 0-180 6083.5 100% Table 3: Zonal Lumen Data Prepared by: Leading Testing Laboratories Page 7 of 13

Chart 2: Illuminance Plot (Footcandles) Prepared by: Leading Testing Laboratories Page 8 of 13

Luminous Intensity Distribution Plots Chart 3: Isocandela Plot Chart 4: Polar Candela Distribution Prepared by: Leading Testing Laboratories Page 9 of 13

Luminous Intensity Data Table 4: Luminous Intensity Data Prepared by: Leading Testing Laboratories Page 10 of 13

Table 5: Luminous Intensity Data Prepared by: Leading Testing Laboratories Page 11 of 13

EQUIPMENT LIST Test Equipment Model Equipment No. Calibration Date Calibration Due Goniophotometer system GO-R5000 HZTE011-01 Aug. 23, 2017 Aug. 22, 2018 Digital Power Meter PF2010A HZTE028-01 Aug. 10, 2017 Aug. 09, 2018 AC Power Supply DPS1060 HZTE001-06 Aug. 10, 2017 Aug. 09, 2018 DC Power Supply WY12010 HZTE004-03 Aug. 10, 2017 Aug. 09, 2018 Standard Source D908 HZTE012-01 Aug. 20, 2017 Aug. 19, 2018 Standard source SCL-1400 HZTE012-02 Aug. 20, 2017 Aug. 19, 2018 Temperature and humidity recorder JR900 HZTE018-01 Aug. 16, 2017 Aug. 15, 2018 Temperature recorder JM624U HZTE018-08 Aug. 17, 2017 Aug. 16, 2018 TEST METHODS Table 6: Test Equipment List date Seasoning of SSL Product For the purpose of rating new SSL products, SSL products shall be tested with no seasoning. Therefore, no seasoning was performed. Goniophotometer Method Photometric and Electrical Measurements An EVERFINE Type C Model GO-R5000 Goniophotometer was used to measure the intensity at each angle of distribution for each sample. The photometric distance is 2.475m for near-field measurement or 30m for far-field measurement. Bandwidth of spectroradiometer is 380nm-780nm. Ambient temperature was measured at the same height of the sample mounted on the Goniophotometer equipment. Each SSL unit was operated on the client provided driver at the rated input voltage in its designated orientation. The stabilization time typically ranges from 30 min (small integrated LED lamps) to 2 or more hours for large SSL luminaires). It can be judged that stability is reached when the variation (maximum minimum) of at least 3 readings of the light output and electrical power over a period of 30 min, taken 15 minutes apart, is less than 0.5 %. Electrical measurements including voltage, current, and power were measured using the Everfine Digital Power Meter. Some graphics were created with Photometric Plus software. The standard reference of the Goniophotometer system is halogen incandescent lamp, the intensity distribution type is omni-directional, and is traceable to the National Institute of Metrology P.R. China. The uncertainty of goniophotometer system reported in this document is expended uncertainty is 2.3% with a coverage factor k=2. Prepared by: Leading Testing Laboratories Page 12 of 13

Color Characteristics Measurements The color characteristics of SSL products include chromaticity coordinates, correlated color temperature, and color rendering index. These characteristics of SSL products may be spatially non-uniform, and thus, in order that they can be specified accurately, the color quantities shall be measured as values that are spatially average, weighted to intensity, over the angular range where light is intentionally emitted from the SSL product. The color characteristics measurements are using gonio-spectroradiometer. Color Spatial Uniformity The characteristics of SSL products may be spatially non-uniform, the chromaticity coordinate shall be measured at two vertical planes (C=0 /180 and C=90 /270 ) and at 10 or less intervals for vertical angle until the light output dropped to below 10% of the peak intensity. The averaged weighted chromaticity coordinate was calculated from these points. The data was then analyzed to check for delta color differences of the u', v' chromaticity coordinates. The spatial non-uniformity of chromaticity, u'v', is determined as the maximum deviation (distance on the CIE (u', v') diagram) among all measured points from the spatially averaged chromaticity coordinate. The geometry for the chromaticity measurement using gonio-spectroradiometer is shown as following. *** End of Report *** This report is considered invalidated without the Special Seal for Inspection of the LTL. This report shall not be altered, increased or deleted. The results shown in this test report refer only to the sample(s) tested. Without written approval of LTL, this test report shall not be copied except in full and published as advertisement. Prepared by: Leading Testing Laboratories Page 13 of 13