PPS MFS series - Installation Guide. Power Protector Stabilizer V 3.8 1

Similar documents
2015 RIGOL TECHNOLOGIES, INC.

WARNINGS & SAFETY INFORMATION: PLEASE READ CAREFULLY AND KEEP A COPY ON THE PROPERTY FOR FUTURE REFERENCE!

SINGLE PHASE BUCK & BOOST TRANSFORMERS INSTRUCTION MANUAL

MODEL W Power Amplifier

AC/DC Current Oscilloscope Probe Model SL261

Tablet Oscilloscope Safety Information

Model 4210-MMPC-L. Multi-measurement Prober Cable Kit. Overview. Quick start guide topics. Related documents

CM605. User Manual AC/DC LOW CURRENT CLAMP-ON METER ENGLISH

Model 5100F. Advanced Test Equipment Rentals ATEC (2832) OWNER S MANUAL RF POWER AMPLIFIER

Digital Clamp Meter. User Manual

INSTRUCTION MANUAL. Type SWF. Sine Wave Filters 690 Volts, 50Hz

Agilent G1888 Network Headspace Sampler

SUNNY BEAM REPEATER Transmission Range Increase for Sunny Beam

INSTALLATION, OPERATION AND MAINTENANCE GUIDE

TEGAM, INC. SINGLE/DUAL CHANNEL HIGH VOLTAGE AMPLIFIER MODEL 2340/2350. Instruction Manual PN# CD Publication Date: June 2006 REV.

Model 4210-MMPC-W. Multi-measurement Prober Cable Kit. Overview

3B SCIENTIFIC PHYSICS

APS M1P Single-phase Micro-inverter Installation and User Manual

USER MANUAL. Maxwell Technologies Ultracapacitor Energy Storage Modules. Models: BMOD0058 E016 B02 BMOD0006 E160 B02. Document

Galaxy VM. Kit for IP32. Installation 06/

User Manual Digital Multimeter

KANEKA OLED Lighting Module SL (LE-01L, LE-02L, LE-03L, LE-01H, LE-02H, LE-03H) Instruction Manual

AMM-1022 Digital Multimeter USER`S MANUAL

Features COMPACT HIGH POWER MONO SUBWOOFER AMPLIFIER. Quick Start Guide

OPERATION MANUAL. Input Block EX250-IE1 EX250-IE2 EX250-IE3

CANARY AUDIO. Power Amplifier CA-309 OWNER S MANUAL. Handcrafted in California MADE IN USA

INTELLIMETER REGISTER

USER'S MANUAL DMR-6700

MARTINDALE INSTRUCTIONS. E-ZeTest EZ2500 LOOP TESTER ELECTRIC. Trusted by professionals. Other products from Martindale:

GETTING STARTED GUIDE NI AI, ±10 V, 24 Bit, 50 ks/s/ch Simultaneous

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

APS M1P Single-phase Micro-inverter Installation and User Manual

2011 / Circuit Tracer

Keysight U1231A/ U1232A/U1233A Handheld Multimeter. Quick Start Guide

INSTALLATION WARNING: BEFORE COMMENCING INSTALLATION ISOLATE YOUR MAINS ELECTRIC SUPPLY

MICRO SERIES MONITORS

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

3B SCIENTIFIC PHYSICS

INSTRUCTION MANUAL LKG 601 Electrical Safety Analyzer

SL Slave Amplifiers. User Manual. Order codes: CRAM37 - SL V 4 x 60W CRAM22 - SL V 4 x 120W CRAM23 - SL V 4 x 240W

Dawson DDM181. Pocket-Size Autorange Digital Meter User s Manual

vacon 100 industrial vacon 100 flow vacon 100 hvac vacon 100 x ac drives du/dt filter technical guide

GETTING STARTED GUIDE NI AI, ±60 V, 24 Bit, 1 ks/s/ch Simultaneous

Agilent U1231A/U1232A/U1233A Handheld Multimeter. Quick Start Guide

QUICK TESTER FOR TRANSFORMERS AND CAPACITORS

ETHOS 5030 TRUE-RMS DIGITAL MULTIMETER OPERATION MANUAL

MS8268 HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS

AC/DC DIGITAL CLAMP METER OPERATION MANUAL

Section 7 Inteli-Touch Series Casablanca Fan Co. - Factory Service Department - Technical Library

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com # # AAC Clamp Meter. Instruction Manual

COMPLY WITH HI-VOLTAGE PHASE CURRENT MEASUREMENT M-140HC INSTRUCTION MANUAL

Instruction Manual ICM 3091N Digital AC Clampmeter EN FR IT DE ES

TOSVERT VF-PS1 series BACnet option unit Instruction Manual BCN001Z

RIGOL. User s Guide. RP1000D Series High Voltage Differential Probe. Feb RIGOL Technologies, Inc

USER MANUAL. WBP314P71 active power transducer. (3-phase 4-wired)

MRG 96RM-E Flex RCM Mobile universal measurement device Supplementary description to the operation manual UMG 96RM-E

PEN TYPE DIGITAL MULTIMETER OPERATION MANUAL T8211D

plifier D-501 otion Am Tactile M

High Performance Current Transducer IT 200-S ULTRASTAB = A. ε L

USER S MANUAL POWER SUPPLY - ISOLATOR - SIGNAL CONVERTER ZSP 41 POWER SUPPLY - ISOLATOR - SIGNAL CONVERTER SIGNAL MULTIPLIER ZSP 41/2

DVM1190 DIGITAL MULTIMETER

Capacitive level meters CLM 40 INSTRUCTIONS MANUAL. průmyslová elektronika

I P. /dt. di p V S+ Applications. Standards. 1) IEC ed1.0: 2007; IEC : ed1.0: 2012

30XR-A Professional Digital Multimeter Users Manual

Page 1 T O O L S A N D M AT E R I A L S R E Q U I R E D. 1. Screwdriver 2. Carpenter's level 3. Electrical Tape PA R T S L I S T. A.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and secondary circuit.

TBX-1329 AC/DC COUPLING TERMINAL BLOCK

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

MS2030 CAT III 600 V A V AUTO RS232

TOS9220 TOS9221 DANGER

ECA COMMERCIAL AMPLIFIER OWNER S MANUAL ECA-70MIXAMP V / 70V / 4Ω Amplifier ECA-70MIXAMP-1-60 OUTPUT LEVEL POWER MASTER MIC 1

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

EOS Direct/Indirect LED Pendant Luminaire

MRG 512-PRO PQ Flex Mobile universal measurement device Supplementary description to the operation manual UMG 512-PRO

DC200A Displacement Clipper User Manual

S&C Scada-Mate Switching Systems Outdoor Distribution Interrupter Replacement 14.4 kv through 34.5 kv

High Performance Current Transducer ITL 900-T = A

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

MODEL 3810/2 Line Impedance Stabilization Network

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information

I P I OUT R L. Applications. Standards. N 52.D ; Page 1/8

LED MIRROR CABINETS 3612-L-6560

TT W Wireless receiver Inline Switch

I Pr I P I OUT R L. Applications. Standards

34134A AC/DC DMM Current Probe. User s Guide. Publication number April 2009

Tel: Fax:

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

DIGIT & POINTER MULTIMETER

TMP40. User Manual.

312, 316, 318. Clamp Meter. Users Manual

2-WIRE UNIVERSAL TEMPERATURE TRANSMITTER

EOS LED Surface Mounted Luminaire

1. SAFETY INFORMATION.1 2. DESCRIPTION SPECIFICATIONS.6 4. OPERATING INSTRUCTION Voltage measurement Current measurement 10

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

I P. /dt. di p V S Applications. Standards 1) IEC : 2007; IEC : ) IEC : 2016; IEC : 2017

AC FLEXIBLE CURRENT PROBE CA 3000

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

User Manual Digital Clamp Multimeter. model no.: MSR-C600

Transcription:

Power Protector Stabilizer MFS Series - Installation Guide - V 3.8 1

1. Safety instructions The following document applies to PPS MFS-i / -ir / -if and PPS MFS-L / -LR What this chapter contains This chapter contains the safety instructions which you must follow when installing, operating and servicing the Power Protector Stabilizer MFS. If ignored, physical injury or death may follow, or damage may occur to the PPS MFS. Read the safety instructions before you work on the unit. Use of warnings and notes There are two types of safety instructions throughout this manual: warnings and notes. Warnings caution you about conditions which can result in serious injury or death and/or damage to the equipment. They also tell you how to avoid the danger. Notes draw attention to a particular condition or fact, or give information on a subject. The warning symbols are used as follows: Dangerous voltage warning warns of high voltage which can cause physical injury and/or damage to the equipment. General warning warns about conditions, other than those caused by electricity, which can result in physical injury and/or damage to the equipment. Electrostatic discharge warning warns of electrostatic discharge which can damage the equipment. Hot surface warning warns of hot surfaces which can cause physical injury. V 3.8 2

1.1. Installation and maintenance work These warnings are intended for all who work on the PPS MFS, or cable. WARNING! Ignoring the following instructions can cause physical injury or death, or damage to the equipment: Only qualified personnel are allowed to install and maintain the PPS MFS. PPS MFS is intended to be built into commercial refrigeration appliances or other enclosures that provide protection against certain external influences and, in any direction, protection against direct contact and electric shock. Never work on the PPS MFS or cable when main power is applied. Always ensure by measuring with a multimeter (impedance at least 1 Mohm) that voltage between device input phases INPUT and NEUTRAL is close to 0V. Do not work on the cables when power is applied to the device or to the external control circuits. Externally supplied control circuits may cause dangerous voltages inside the device even when the main power on the drive is switched off. Do not make any insulation or voltage withstand tests on the device. When reconnecting the wiring, always check that the phase order is correct. Do not change the electrical installations of the PPS MFS. Changes may affect the safety performance or operation of the device unexpectedly. All customermade changes are on the customer's responsibility. Note: The fast-on terminals on the device are at a dangerously high voltage when the input power is on. V 3.8 3

1.2. Mechanical installation and maintenance These instructions are intended for all who install and service the PPS MFS. WARNING! Ignoring the following instructions can cause physical injury or death, or damage to the equipment: Handle the unit carefully. It shall be installed in an area where it is inaccessible without disassembly of the enclosing area. The PPS MFS made of two parts, the Electronic Control Unit - ECU - and the Autotransformer - TRAFO. None of these parts are serviceable or repairable. Beware of hot surfaces. Some parts, such as transformer, may remain hot for a while after disconnection of the electrical supply. Make sure that dust from borings and grindings does not enter the drive when installing. Electrically conductive dust inside the unit may cause damage or malfunctioning. Ensure for adequate cooling. Do not fasten the device by welding. 1.3. Printed circuit boards WARNING! Ignoring the following instructions can cause damage to the printed circuit boards: The printed circuit boards contain components sensitive to electrostatic discharge. Wear a grounding wrist band when handling the boards. Do not touch the boards unnecessarily. Operation These warnings are intended for all who plan the operation of the drive or operate the drive. WARNING! Ignoring the following instructions can cause physical injury or death, or damage to the equipment: Before powering the device check the wiring. V 3.8 4

2. Mechanical installation What this chapter contains This chapter contains packing information and the mechanical installation instructions of the device. 2.1 Packing of the unit The Electronic Control Unit- ECU - of the device is delivered in a cardboard box. The Autotransformer - Trafo - of the device is delivered in a cardboard box. The type, size and material of the package depend on the frame size of the Autotransformer. 2.2 Before installation The device must be installed in an upright position (beside figure) with allowance for adequate cooling. IP rating is met only when the ECU is installed in a vertical position with the connection tabs at the bottom. This is also important as the ECU also detects ambient temperature as one of its features. 2.3 Dimensional drawings for the ECU (Electronic Control Unit) installation 114,00mm 11,50 mm 32,00mm Ø5,00mm 98,00mm 80,00mm Ø5,00mm V 3.8 5

Top View 80,00mm 98,00mm 1,50mm 11,50mm 114,00mm 31,00mm 14,00mm 31,00mm 2,00mm 14,00mm 32,00mm Side Views Ø5,00mm 111.00mm Ø5,00mm 50.50mm Holes for Screw V 3.8 6

2.4 Dimensional drawings for Autotransformer. A E C B D All dimensions are in mm. Dimensions of Autotransformers are indicated below Trafo MFS- xxx i XXX : 045 070 090 120 170 220 270 A 105 110 110 120 122 135 140 B 75 75 86 86 94 105 105 C 84 84 96 96 108 120 120 D 50 55 55 65 68 72 77 E 73 73 82 82 93 104 104 Trafo MFS- xxx ir XXX : 045 070 090 120 170 220 270 A 110 120 130 140 132 140 150 B 75 75 86 86 94 105 105 C 84 84 96 96 108 120 120 D 55 65 65 75 78 77 87 E 73 73 82 82 93 104 104 Trafo MFS- xxx L XXX : 040L 060L 070L 085L 100L 150L 200L A 106 116 120 127 133 138 150 B 86 86 86 86 86 103 101 C 96 96 96 96 96 120 115 D 54 62 65 72 78 75 87 E 82 82 82 82 82 104 105 Trafo MFS- xxx LR XXX : 070 L 085 L 100 L 150 L 200 L A 130 137 143 147 160 B 86 86 86 101 101 C 96 96 96 115 115 D 65 72 78 74 87 E 82 82 82 100 100 V 3.8 7

3. Electrical installation What this chapter contains This chapter describes the electrical installation procedure of the drive. WARNING! The work described in this chapter may only be carried out by a qualified electrician. Follow the Safety instructions on the first pages of this manual. Ignoring the safety instructions can cause injury or death. Make sure that the device is disconnected from the mains (input power) during installation. 3.1 Checking the insulation of the installation Device Do not make any insulation resistance tests on any part of the PPS MFS as testing can damage the device. The Autotransformer has been tested for insulation between the main circuit and the chassis at the factory. Moreover, the voltage limiting circuits incorporated in the PPS MFS will cut down the testing voltage automatically, during an insulation resistance test. Supply cable Check the insulation of the supply (input) cable according to local regulations before connecting to the drive. PPS MFS is intended to be used with the protection of a fuse gg, type B, IEC60269-3-1. Confirm compatibility with connection terminals as well as insulation. The connectors are Fast On terminals 6.3x0.8mm 3.2 Main Supply Connection Diagram Line Neutral Ground * Load NEUTRAL INPUT OUTPUT MFS Plate MFS Transformer V 3.8 8

*: Detail of grounding Transformer Enclosure during implementation in the appliance from the installer: Care should be exercised from the installer to the following: The transformer hole and the screw used for Ground conductor connection must not be used for other reason (i.e. mechanical support etc.) Earth Conductor must be at least 2,5mm 2 of the flexible stranded type. Should the conductor be more than 1 meter in length, earth resistance must be verified to be less than 0.1Ω. Earth connection must be realized near the point of the Incoming Protective earth (ground) of the appliance in which the PPS MFS is incorporated, marked with the symbol: (IEC 60417-5019) V 3.8 9

3.3 Connection between ECU and Autotransformer The PPS MFS made of two parts, the Electronic Control Unit - ECU - and the Autotransformer - TRAFO. The connection between ECU and Autotransformer must be made by using faston terminals. The length of the cable between ECU and Autotransformer can be 250mm, 550mm, 1000mm or 1200mm and depends on needs of customer. WARNING! Ignoring the following instructions can cause damage to the equipment and/or violate design specifications. PPS MFS is made up of non-repairable / refurbishable parts. In the event of a failure of the PPS MFS, both ECU and TRAFO have to be replaced with new unused units. Part replacement is not advisable. Before powering the device: Confirm color coding between ECU and Autotransformer Confirm the correct fitting of the terminals to ensure IP rating of the connections. V 3.8 10

Further Information Support: rnd@thyratron.gr Sales: sales@thyratron.gr Site: www.thyratron.gr Follow us at linked in, Google+, Facebook Address: Kydonies Vasiliko, Erymanthos, Achaia, GR25008, GREECE Tel: +30 26940 61868 Fax: +30 26940 62001 V 3.8 11