Simulation and Analysis of ASCAD Multilevel Inverter with SPWM for Photovoltaic System

Similar documents
Simulation and Analysis of MPPT Control with Modified Firefly Algorithm for Photovoltaic System

A Single-Phase Carrier Phase-shifted PWM Multilevel Inverter for 9-level with Reduced Switching Devices

COMPARATIVE STUDY OF DIFFERENT TOPOLOGIES OF FIVE LEVEL INVERTER FOR HARMONICS REDUCTION

Literature Survey: Multilevel Voltage Source Inverter With Optimized Convention Of Bidirectional Switches

Performance Evaluation of Single Phase H-Bridge Type Diode Clamped Five Level Inverter

Simulation of Three Phase Cascaded H Bridge Inverter for Power Conditioning Using Solar Photovoltaic System

Simulation and Analysis of Symmetric Seven-level CMLI using Multicarrier SPWM Technique with Reducing Number of Switches

Performance Evaluation of Multi Carrier Based PWM Techniques for Single Phase Five Level H-Bridge Type FCMLI

A Novel Asymmetric Three-Phase Cascaded 21 Level Inverter Fed Induction Motor Using Multicarrier PWM with PI and Fuzzy Controller

CARRIER BASED PWM TECHNIQUE FOR HARMONIC REDUCTION IN CASCADED MULTILEVEL INVERTERS

COMPARATIVE STUDY OF PWM TECHNIQUES FOR DIODE- CLAMPED MULTILEVEL-INVERTER

Study of five level inverter for harmonic elimination

Analysis of New 7- Level an Asymmetrical Multilevel Inverter Topology with Reduced Switching Devices

Performance Improvement of Multilevel Inverter through Trapezoidal Triangular Carrier based PWM

Switching of Three Phase Cascade Multilevel Inverter Fed Induction Motor Drive

Symmetrical Multilevel Inverter with Reduced Number of switches With Level Doubling Network

Simulation of Five-Level Inverter with Sinusoidal PWM Carrier Technique Using MATLAB/Simulink

International Journal of Advance Engineering and Research Development

Keywords Asymmetric MLI, Fixed frequency phase shift PWM (FFPSPWM), variable frequency phase shift PWM (VFPSPWM), Total Harmonic Distortion (THD).

International Journal of Advance Engineering and Research Development

Design and Implementation of 3-Phase 3-Level T-type Inverter with Different PWM Techniques

A Comparative Analysis of Modified Cascaded Multilevel Inverter Having Reduced Number of Switches and DC Sources

Reduction of THD in Thirteen-Level Hybrid PV Inverter with Less Number of Switches

THD Minimization in Single Phase Symmetrical Cascaded Multilevel Inverter Using Programmed PWM Technique

Comparison of carrier based PWM methods for Cascaded H-Bridge Multilevel Inverter

Analysis of Asymmetrical Cascaded 7 Level and 9 Level Multilevel Inverter Design for Asynchronous Motor

A Modified Cascaded H-Bridge Multilevel Inverter topology with Reduced Number of Power Electronic Switching Components

Performance Metric of Z Source CHB Multilevel Inverter FED IM for Selective Harmonic Elimination and THD Reduction

SINGLE PHASE THIRTEEN LEVEL INVERTER WITH REDUCED NUMBER OF SWITCHES USING DIFFERENT MODULATION TECHNIQUES

CASCADED H-BRIDGE MULTILEVEL INVERTER FOR INDUCTION MOTOR DRIVES

Modified Multilevel Inverter Topology for Driving a Single Phase Induction Motor

A Comparative Study of SPWM on A 5-Level H-NPC Inverter

Simulation & Implementation Of Three Phase Induction Motor On Single Phase By Using PWM Techniques

Harmonic Evaluation of Multicarrier Pwm Techniques for Cascaded Multilevel Inverter

An Implementation of 9-Level MLI using IPD-Topology for Harmonic Reduction

Nine-Level Cascaded H-Bridge Multilevel Inverter Divya Subramanian, Rebiya Rasheed

A Comparative Analysis of Multi Carrier SPWM Control Strategies using Fifteen Level Cascaded H bridge Multilevel Inverter

A Novel Cascaded Multilevel Inverter Using A Single DC Source

MATLAB Implementation of a Various Topologies of Multilevel Inverter with Improved THD

Multilevel Inverters : Comparison of Various Topologies and its Simulation

Multilevel Inverter with Coupled Inductors with Sine PWM Techniques

Asymmetrical 63 level Inverter with reduced switches and its switching scheme

Simulation and Experimental Results of 7-Level Inverter System

Design and Development of Multi Level Inverter

Level Shifted Pulse Width Modulation in Three Phase Multilevel Inverter for Power Quality Improvement

Comparison of Multi Carrier PWM Techniques applied to Five Level CHB Inverter

ISSN Vol.05,Issue.05, May-2017, Pages:

Simulation of Cascade H-Bridge Multilevel Inverter With Equal DC Voltage Source

SIMULATION, DESIGN AND CONTROL OF A MODIFIED H-BRIDGE SINGLE PHASE SEVEN LEVEL INVERTER 1 Atulkumar Verma, 2 Prof. Mrs.

Total Harmonics Distortion Investigation in Multilevel Inverters

Simulation of Multilevel Inverter Using PSIM

ANALYSIS OF PWM STRATEGIES FOR Z-SOURCE CASCADED MULTILEVEL INVERTER FOR PHOTOVOLTAIC APPLICATIONS

Study of Unsymmetrical Cascade H-bridge Multilevel Inverter Design for Induction Motor

NEW VARIABLE AMPLITUDE CARRIER OVERLAPPING PWM METHODS FOR THREE PHASE FIVE LEVEL CASCADED INVERTER

Speed Control of Induction Motor using Multilevel Inverter

A Novel Multilevel Inverter Employing Additive and Subtractive Topology

ADVANCED PWM SCHEMES FOR 3-PHASE CASCADED H-BRIDGE 5- LEVEL INVERTERS

Analysis and Simulation of a Cascaded H-Bridge Structure Electrical Converter With Separate DC Supply

MULTICARRIER TRAPEZOIDAL PWM STRATEGIES FOR A SINGLE PHASE FIVE LEVEL CASCADED INVERTER

A Modified Apod Pulse Width Modulation Technique of Multilevel Cascaded Inverter Design

Harmonic Analysis & Filter Design for a Novel Multilevel Inverter

Reduction of Power Electronic Devices with a New Basic Unit for a Cascaded Multilevel Inverter fed Induction Motor

ADVANCES in NATURAL and APPLIED SCIENCES

SINGLE PHASE THIRTY ONE LEVEL INVERTER USING EIGHT SWITCHES TOWARDS THD REDUCTION

ISSN: International Journal of Science, Engineering and Technology Research (IJSETR) Volume 1, Issue 5, November 2012

Performance Analysis of Three Phase Cascaded H-Bridge Multi Level Inverter for Voltage Sag and Voltage Swell Conditions

Cascaded Connection of Single-Phase & Three-Phase Multilevel Bridge Type Inverter

Three Phase 11-Level Single Switch Cascaded Multilevel Inverter

MULTILEVEL INVERTER WITH LEVEL SHIFTING SPWM TECHNIQUE USING FEWER NUMBER OF SWITCHES FOR SOLAR APPLICATIONS

Hardware Implementation of SPWM Based Diode Clamped Multilevel Invertr

Hybrid Modulation Technique for Cascaded Multilevel Inverter for High Power and High Quality Applications in Renewable Energy Systems

IMPLEMENTATION OF MODIFIED REDUCED SWITCH MULTILEVEL INVERTER USING MCPWM AND MSPWM TECHNIQUES

Analysis of Cascaded Multilevel Inverters with Series Connection of H- Bridge in PV Grid

Series Parallel Switched Multilevel DC Link Inverter Fed Induction Motor

Low Order Harmonic Reduction of Three Phase Multilevel Inverter

Comparison between Conventional and Modified Cascaded H-Bridge Multilevel Inverter-Fed Drive

A NEW SYMMETRIC CASCADED MULTILEVEL INVERTER TOPOLOGY WITH REDUCED NUMBER OF POWER ELECTRONIC COMPONENTS

IJSRD - International Journal for Scientific Research & Development Vol. 4, Issue 04, 2016 ISSN (online):

CHAPTER 3 SINGLE SOURCE MULTILEVEL INVERTER

Fuzzy based Speed Control of Brushless DC Motor fed Electric Vehicle

A Single-Phase Cascaded Multilevel Inverter Based on a New Basic Unit with Reduced Number of Power Switches

A New Multilevel Inverter Topology with Reduced Number of Power Switches

New Multi Level Inverter with LSPWM Technique G. Sai Baba 1 G. Durga Prasad 2. P. Ram Prasad 3

SEVEN LEVEL HYBRID ACTIVE NEUTRAL POINT CLAMPED FLYING CAPACITOR INVERTER

ANALYSIS AND IMPLEMENTATION OF FPGA CONTROL OF ASYMMETRIC MULTILEVEL INVERTER FOR FUEL CELL APPLICATIONS

Fifteen Level Hybrid Cascaded Inverter

Grid Tied Solar Panel Interfacing using 2( Level Inverter with Single Carrier Sinusoidal Modulation; where N is the number of H-bridges

Australian Journal of Basic and Applied Sciences. Simulation and Analysis of Closed loop Control of Multilevel Inverter fed AC Drives

International Journal Of Engineering And Computer Science ISSN: Volume 2 Issue 12 December, 2013 Page No Abstract

Modified Transistor Clamped H-bridge-based Cascaded Multilevel inverter with high reliability.

Simulation and Analysis of Efficient Multilevel Inverter for Solar Panel: Review Paper

SIMULATION OF THREE PHASE MULTI- LEVEL INVERTER WITH LESS NUMBER OF POWER SWITCHES USING PWM METHODS

A New 5 Level Inverter for Grid Connected Application

A New Transistor Clamped 5-Level H-Bridge Multilevel Inverter with voltage Boosting Capacity

Design of PI controller for seven level symmetrical MLI with minimal quantity of switches plus snubber circuit

A Single Dc Source Based Cascaded H-Bridge 5- Level Inverter P. Iraianbu 1, M. Sivakumar 2,

Multilevel Inverter Based Statcom For Power System Load Balancing System

CHAPTER 5 Z-SOURCE MULTILEVEL INVERTER FOR UPS APPLICATIONS

Three-Phase Five-Level Flying Capacitor Multilevel inverter For Harvesting Solar Power

Available online at ScienceDirect. Procedia Technology 21 (2015 ) SMART GRID Technologies, August 6-8, 2015

Transcription:

Simulation and Analysis of ASCAD Multilevel Inverter with S for Photovoltaic System K.Aswini 1, K.Nandhini 2, S.R.Nandhini 3, G.Akalya4, B.Rajeshkumar 5, M.Valan Rajkumar 6 Department of Electrical and Electronics Engineering, Gnanamani College of Technology, Namakkal, Tamilnadu, India Abstract: In high voltage and high power application the multilevel inverter (MLI) is more popular one. To obtain high voltages with low harmonics and lower electromagnetic interference (EMI) the multilevel inverter used as unique structure and it also different from other topologies. This paper presents that the 21- level of multilevel inverter using Asymmetrical Cascaded MLI topology. With the help of single phase with various different techniques, multilevel inverter is implemented. The technique used in this paper is sinusoidal pulse width modulation (S). When compared with other topologies it requires only less number of components and circuits of gate drive. By using of MATLAB/Simulink R2014a software version the simulation result will be obtained. Keywords: Multilevel inverter (MLI), Asymmetrical cascaded Multilevel Inverter (ACMLI) topology and sinusoidal pulse width modulation (S). 1. INTRODUCTION Multi-level power conversion is used to provide more than two voltage level to achieve smoother and less distorted dc to ac power conversion and it can generate a multiple-step voltage waveform with less distortion, less switching frequency and higher efficiency. Multilevel inverters have become more popular over the years in high power and high voltage applications. Whereas conventional two level inverter have some limitations in high power high voltage applications due to switching losses and power ratings [1-5]. Multilevel inverter offers several advantages over twolevel inverter: it improves the output voltage waveform, reduced (dv/dt) voltage stress on the load and also reduces electromagnetic interference problems, but it has some disadvantages when the number of voltage levels increases such as; complex controlling method, voltage balancing problems are introduced and higher number of semiconductor switches are required. Each switch requires a separate gate driver circuit, therefore increasing the complexity and size of the overall circuit. For this problem, lower voltage rated switches can be used in multilevel inverter instead of higher number of semiconductor switches which can be used to minimized cost of the semiconductor switches as compared to two level inverters [6-8].There are different conventional multi-level inverters topology mainly classified as Diode clamped multilevel inverter (DCMLI) [9-10], Flying capacitor inverter (FCMLI), cascaded H-bridge multilevel inverter (CHBMLI). In 1981 a three level diode clamped multilevel inverter schemes proposed by nabae [11]. The flying capacitor inverter structure is similar to that of diode clamped inverter but the main difference is that instead of clamping diodes, flying Capacitors are used. The control method of cascaded H Bridge multilevel is more convenient than other multilevel inverter because it doesn t have any clamping diode and flying capacitor. Cascaded multilevel inverter reaches higher reliability [12-15]. The cascaded inverter is used for large automotive electric drives. However, the requirement of more number of switches and separate dc source for each cell becomes a problem especially at higher level. Cascaded h-bridge multilevel inverter consists of separate dc links for each h-bridge cell so it is easily controllable. Cascaded h-bridge multilevel inverter has some drawback that by increasing the number of voltage levels numbers of switching devices given by 2(N+1) also increase [16]. This paper proposes a 21- level multi-level inverter with ACMIL topology which requires less number of switches and gate driver circuits as compared to conventional multilevel inverters. The proposed multilevel inverter topology [17-21] here is implemented in single-phase with different techniques. The pulse-width modulation () control is the most efficient technique of controlling output voltage within the inverters. The carrier based schemes used for multilevel inverters is the most efficient method, realized by the intersection of a 2017, IJISSET Page 1

modulating signal with triangular carrier waveform. The paper tries to prove that ACMIL topology is better than conventional multilevel inverters topology in terms of their number of components and THD. 2. PROPOSED TOPOLOGY A single DC supply to output voltages two level 0 and V. It is used two switches S1 and S2. If switch S1 is ON, output voltage are V and switch S2 is ON output voltage are zero. Switches S1 and S2 are OFF simultaneously to avoid the occurrence of short circuit across the DC supply. A three-phase asymmetrical n-level reduced devices cascading inverter shown in Fig.1 In this circuit, the DC-bus voltage is split into each cell. Which are connected in series and desired number of level can be achieved by series connection of switch. The proposed ACMLI topology for 21-level inverter requires twelve semiconductor switches and four isolated dc sources shown in Fig2 [9] which separates output voltage in two parts. One part is called level generation part (left side) and is responsible for level generating in positive polarity & negative polarity. The main purpose of this proposed ACMLI topology is to control the EMI, minimize the total harmonic distortion with different techniques and it also minimizes power semiconductor switches than conventional multilevel inverter. For a conventional single-phase 21-level inverter, it uses 40 switches, whereas the proposed topology uses only 12 switchesphase MLI with the same principle. The proposed topology is a symmetrical topology because all the values of all voltage sources are equal. Therefore, it does not have voltage-unbalancing due to fixed dc voltage values. In comparison with a cascade h-bridge inverter topology, proposed topology simulations [11] requires only one-third of isolated power. The major advantage of the proposed configuration is that in continuous current mode of operation contents can be reduced drastically. Here proposed topology is also used for three supplies used in a cascade-type inverter [10]. Fig 2: Proposed single-phase asymmetrical cascade 21-level inverter for line to ground voltages 3. OPERATION FOR THE PROPOSED TOPOLOGY Fig 1: Proposed n-level asymmetrical reduced device cascaded MLI The other part is called polarity generation part (right side) and is responsible for generating the polarity of the output voltage. This topology combines the two parts (left part and right part) to generate the multilevel output voltage waveform. The operation of the proposed topology has been discussed in detail and has been verified with the help of with 10Vdc (i.e., level +10). Operation of the proposed 21-level MLI The output voltage will be 9Vdc (i.e., level +9) when switches S2, S3, S5 and S7 are turned on. When S1, S4, S5 and S7 switches are turned on the output voltage will be 8Vdc (i.e., level +8). 2017, IJISSET Page 2

Voltage Level SWITCHING STATE S1 S2 S3 S4 S5 S6 S7 S8 S9 S10 S11 S12 +10 1 0 1 0 1 0 1 0 1 1 0 0 10V +9 0 1 1 0 1 0 1 0 1 1 0 0 9V +8 1 0 0 1 1 0 1 0 1 1 0 0 8V +7 0 1 0 1 1 0 1 0 1 1 0 0 7V +6 1 0 1 0 1 0 0 1 1 1 0 0 6V +5 1 0 0 1 0 1 1 0 1 1 0 0 5V +4 0 1 0 1 0 1 1 0 1 1 0 0 4V +3 1 0 1 0 0 1 0 1 1 1 0 0 3V +2 0 1 1 0 0 1 0 1 1 1 0 0 2V +1 1 0 0 1 0 1 0 1 1 1 0 0 V 0 0 1 0 1 0 1 0 1 1 1 0 0 0-1 1 0 0 1 0 1 0 1 0 0 1 1 -V -2 0 1 1 0 0 1 0 1 0 0 1 1-2V -3 1 0 1 0 0 1 0 1 0 0 1 1-3V -4 0 1 0 1 0 1 1 0 0 0 1 1-4V -5 1 0 0 1 0 1 1 0 0 0 1 1-5V -6 1 0 1 0 1 0 0 1 0 0 1 1-6V -7 0 1 0 1 1 0 1 0 0 0 1 1-7V -8 1 0 0 1 1 0 1 0 0 0 1 1-8V -9 0 1 1 0 1 0 1 0 0 0 1 1-9V OUTPUT VOLTAGE Fig (c) 4. MODES OF OPERATION: Fig (d) Fig (a) Fig (b) Fig (e) 2017, IJISSET Page 3

Fig (f) Fig (i) Fig (g) Fig (j) Fig (h) Fig (k) 2017, IJISSET Page 4

Fig (l) Fig (o) Fig (m) Fig (p) Fig (n) Fig (q) 2017, IJISSET Page 5

When switches S 1, S 3, S 5 and S 7 are turned on the output voltage will be the output voltage will be 5Vdc (i.e., level +5) when switches S 1, S 4, S 6 and S 7 are turned on. When S 2, S 4, S 6 and S 7 switches are turned on the output voltage will be 4Vdc (i.e., level +4). When switches S2, S4, S5 and S7 are turned on the output voltage will be 7Vdc (i.e., level +7). When switches S1, S3, S5 and S8 are turned on the output voltage will be 6Vdc (i.e., level +6).asymmetrical cascaded topology can be easily explained with the help of fig. 2 and table I. continuous current operation the current of both thyristors overlaps. Fig (r) Fig (s) Fig (t) 5. MODULATION STRATEGIES MULTILEVEL INVERTER MULTICARRIER WAVEFORM When switches S 1, S 3, S 6 and S 8 are turned on the output voltage will be 3Vdc (i.e., level +3). The output voltage will be 2Vdc (i.e., level +2) when switches S 2, S 3, S 6 and S 8 are turned on. When S 1, S 4, S 6 and S 8 switches are turned on the output voltage will be V dc (i.e., level +1). When switches S 2, S 4, S 6 and S 8 are turned on the output voltage is zero (i.e., level 0). Switches S 9, S 10, S 11 and S 12 are used for a complementary pair. When S 10 and S 11 are turned on together, positive half cycle (level: +1, +2, +3, and +4) can be generated and when S 9 and S 12 are turned on together, negative half cycle (level: -1, -2, -3, and -4) can be generated across load. But the increase of level adds to the cost of converter and more number of secondary windings. So, a suitable compromise has to be made between the THD of the line current and cost of additional hardware. When the circuit works in inverter mode, the dc source transfers power to the main (ac source). The THD and Power flow analysis is done for various configuration of switching angles. The effect of variation of dc voltage on the THD and the power transfer is also analyzed. Though a battery has been considered as a dc source for simulation as well as experimental analysis, the result obtained can be utilized when using solar PV panel. The major advantage of the proposed configuration is that in continuous current mode of operation, the waveform resembles a stepped sinusoidal wave and with suitable selection of switching angles the harmonic contents can be reduced drastically. In general, the load current can be either continuous or discontinuous. LEVEL -SHIFTED PHASE DISPOSITION PHASE-SHIFTED PHASE OPPOSITION DISPOSITION CARRIER OVERLAPPING CARRIER FREQUENCY ALTERNATE PHASE OPPOSITION DISPOSITION There are different pulse width modulation strategies as given below [12-13].Phase disposition pulse width modulation (PD ):- In phase disposition pulse width modulation strategy, where all carrier waveforms are in same phase. Phase opposition disposition pulse width modulation (POD ):- In phase opposition disposition pulse width modulation strategy, where all carrier waveforms above zero 2017, IJISSET Page 6

reference are in phase and below zero reference are 1800 out of phase. Alternate phase opposition disposition pulse width modulation (APOD ):- In alternate phase opposition disposition scheme where every carrier waveform is in out of phase with its neighbor carrier by 180. Phase-shifted pulse width modulation (PS ):- A carrier phase shifted for multi-level inverter is used to generate the stepped multi-level output voltage waveform with lower percentage THD. In proposed, before implementing the Multicarrier Techniques, the gating signals of multi-level inverter switches are generated by comparing sinusoidal reference wave with triangular carrier waves at specific intervals of time producing the characteristic multistep output waveform. MLI with N levels requires (N-1) triangular carriers. In phase shifted, all the triangular carriers have same frequency and same peak to peak amplitude. Fig 6.4: FFT analysis by PS for R-L load (Ma=1.0, Mf=20). 6. SIMULATION RESULTS The Fig.1 & 2 shows the proposed topology model of single-phase n-level & single-phase 21-level ACMLI. Table II shows THD comparison between different techniques. The simulation parameters are as following R = 10 ohms, L = 10mH, and dc source voltage is 400V; Carrier signal frequency is 1 khz. In this paper, four techniques are used PD, POD, APOD, PS, VF and CO with different modulation index (Ma). For Ma = 1.0, and Mf = 20, corresponding (%) THD are PS = 5.54, PD = 5.78, POD = 6.01, APOD = 5.10, shown in Fig. 6.1 6.6. Fig 7: Required number of single phase components for different multi-level inverter topologies. Fig. 7 shows the required number of single phase components for different multilevel inverter topologies. So it is clearly shows that the proposed ACMLI topology is requires less number of components than other conventional topologies so as the voltage level increases the number of components will decreases particularly for higher voltage levels [14-15]. 7. CONCLUSION Fig 4: Single-Phase current by PS for 24-level inverter with R-L load Fig 5: Single-Phase Voltage by PS for 24-level inverter with R-L load In this project, we are reducing the harmonic contents and number of switches using a new topology. It is proved that, the proposed work of Single phase 21- level MLI output voltage THD is reduced and improve the efficiency of system compare with different conventional topologies of single phase and threephase 21-level MLI. Harmonic analysis carried out using MATLAB R2014a version software. This proposed MLI topology requires less number of components as compared to conventional MLI inverters. Simulation results show the performance of single-phase MLI with different techniques. 2017, IJISSET Page 7

REFERENCES [1] A. Chel, G.N. Tiwari, A. Chandra, Simplified method of sizing and life cycle cost assessment of buildings integrated photovoltaic system, Energy and Buildings 41 (2009) 1172-1180. [2] F. Blaabjerg, Z. Chen, S. Kjaer, Power electronics as efficient interface in dispersed power generation systems, IEEE Transactions on Power Electronics 19 (2004) 1184-1194. [3] M.Valan Rajkumar, P.S.Manoharan, Modeling and Simulation of Three-phase DCMLI using SV for Photovoltaic System, Springer Lecture Notes in Electrical Engineering, under the volume titled Power Electronics & Renewable Energy Systems", Volume 326, Chapter No 5, January 2015, Pages 39-45. [4] M.Valan Rajkumar, P.S.Manoharan, Harmonic Reduction of Fuzzy PI Controller based Three- Phase Seven-level DCMLI with SV for Grid Connected Photovoltaic System, Journal International Review on Modeling and Simulations, Volume 6, No 3, June 2013, Pages 684-692. [5] S. Subiyanto, A. Mohamed, M.A. Hannan, Intelligent maximum power point tracking for PV system using Hopfield neutral network optimized fuzzy logic controller, Energy and Buildings 51 (2012) 29-38. [6] M.Valan Rajkumar, P.S.Manoharan, FPGA Based Multilevel Cascaded Inverters with SV Algorithm for Photovoltaic system, Elsevier Journal Solar Energy, Volume 87, Issue 1, January 2013, Pages 229-245. [7] Lian Lian Jiang, Douglas L. Maskell, Jagdish C. Patra, A novel ant colony optimization-based maximum power point tracking for photovoltaic systems under partially shaded conditions, Energy and Buildings 58 (2013) 227-236. [8] Jose Rodriguez, Jih-Sheng Lai, Fang Zheng Peng, Multilevel inverters: a survey of topologies, controls, and applications, IEEE Transactions on Industrial Electronics 49 (2002) 724-738. [9] Colak, Ilhami, Kabalci, Ersan, Bayindir, Ramazan, Review of multilevel voltage source inverter topologies and control schemes, Energy Conversion and Management 52 (2011) 1114-1128. [10] P.Thirumurugan, P.S.Manoharan, M.Valan Rajkumar, VLSI Based Space Vector Pulse Width Modulation Switching Control in the proceedings of IEEE International Conference on Advanced Communication Control and Computing Technologies ICACCCT 2012 on August 2012, ISBN No. 978-1-4673-2045-0 (Print) (Page):366-370. [11] M.Valan Rajkumar, P.S.Manoharan, Space Vector Pulse Width Modulation of Three-Phase DCMLI with Neuro-Fuzzy MPPT for Photovoltaic System, World Journal of Modelling and Simulation, Volume 10, No 3, August 2014, Pages 193-205. [12] Ghazanfari, A., Mokhtari, H. and Firouzi, M. (2012) Simple Voltage Balancing Approach for CHB Multilevel Inverter Considering Low Harmonic Content Based on a Hybrid Optimal Modulation Strategy. IEEE Transactions on Power Delivery, 27, 2150-2158. http://dx.doi.org/10.1109/tpwrd.2012.220527 7 [13] M.Valan Rajkumar, Prakasam, P. and Manoharan, P.S. (2016) Investigational Validation of PV Based DCD-MLI Using Simplified SVM Algorithm Utilizing FPGA Tied with Independent Sources. Circuits and Systems, Volume 7, No 11, 3831-3848. http://dx.doi.org/10.4236/cs.2016.711320 [14] Kavousi, A., Vahidi, B., Salehi, R., Bakhshizadeh, M.K., Farokhnia, N. and Fathi, S.H. (2012) Application of the Bee Algorithm for Selective Harmonic Elimination Strategy in Multilevel Inverters. IEEE Transactions on Power Electronics, 27, 1689-1696. http://dx.doi.org/10.1109/tpel.2011.2166124 [15] M.Valan Rajkumar, P.S.Manoharan, Modeling, Simulation and Harmonic Reduction of Three- Phase Multilevel Cascaded Inverters with SV for Photovoltaic System, Journal International Review on Modeling and Simulations, Volume 6, No. 2, April 2013, Pages 342-350. ISSN: 1974-9821 (Print), 1974-982X (Online) (Impact Factor: 1.199) [16] M.Valan Rajkumar, P.S.Manoharan, Modeling and Simulation of Five-level Five-phase Voltage Source Inverter for Photovoltaic Systems, Journal Przeglad Elektrotechniczny, Volume 10, No. 10, October 2013, Pages 237-241. ISSN: 0033-2097 (Print) (Impact Factor: 0.244) 2017, IJISSET Page 8

[17] A.Ravi, P.S.Manoharan, M.Valan Rajkumar, Harmonic Reduction of Three-Phase Multilevel Inverter for Grid connected Photovoltaic System using Closed Loop Switching Control, Journal- IREMOS, Volume 5, No 5, October 2012, Pages 1934-1942. ISSN: 1974-9821 (Print), 1974-982X (Online) (Impact Factor: 1.199) [18] P.Thirumurugan, P.S.Manoharan, M.Valan Rajkumar, VLSI Based Inverter Switching Control in the proceedings of International Conference on Mathematical Modeling and Applied Soft Computing MMASC 12 Coimbatore Institute of Technology on July 2012, Vol-2 (Page):965-973. [19] IEEE Std 929-2000 (2002) Recommended Practices for Utility Interface of Photovoltaic System. The Institute of Electrical and Electronics Engineers. [20] C.Hemalatha, M.Valan Rajkumar, G.Vidhya Krishnan, Simulation and Analysis for MPPT Control with Modified firefly algorithm for photovoltaic system, International Journal of Innovative Studies in Sciences and Engineering Technology, Volume 2, No 11, Nov.2016, Pages 48-52. [21] G.Vidhya Krishnan, M.Valan Rajkumar, C.Hemalatha, Modeling and Simulation of 13- level Cascaded Hybrid Multilevel Inverter with less number of Switches, International Journal of Innovative Studies in Sciences and Engineering Technology, Volume 2, No 11, Nov.2016, Pages 43-47 2017, IJISSET Page 9