Safety relays - PSR-SCP- 24DC/ESD/4X1/

Similar documents
PSR-SCP- 24DC/ESD/5X1/1X2/300

Signal conditioner - MACX MCR-UI-UI-NC

High-current terminal block - UKH

Feed-through terminal block - PT 10-TWIN

TRIO-PS/1AC/24DC/ 5. Extract from the online catalog. Order No.:

DEK-OV- 12DC/ 24DC/ 3

EMD-FL-3V-400. Electronic monitoring relay for voltage monitoring in three-phase networks. INTERFACE Data sheet _en_03. 1 Description.

MACX MCR-EX-T-UI-UP. Extract from the online catalog. Order No.:

Online data sheet UE43-3AR3D2 UE43-3AR SAFETY RELAYS

Online data sheet UE48-3OS2D2 UE48-3OS SAFETY RELAYS

Online data sheet UE48-2OS2D2 UE48-2OS SAFETY RELAYS

MACX MCR-EX-SL-RPSSI-I

Electronic timer CT-ERS ON-delayed with 2 c/o contacts Data sheet

EMD-FL-C-10. Current Monitoring Relay. Data Sheet. Functions. Structure 08/2004

Extract from the online catalog

NSD Safety Mat Controller Modules Both Modules are compliant to OSHA & ANSI Standards - EN ISO EN EN 81-1 EN NSD VDC

Circuit diagram. Applications. Function. Function (Continued) Page 23 SNO 4062K /K-A /KM /KM-A

Online data sheet UE45-3S13D33 UE45-3S1 SAFETY RELAYS

Switching power supplies CP range, Linear power supplies CP-L range. Content

SMKDSP 1,5/ 8. Extract from the online catalog. Order No.:

MCR-C-UI-UI-DCI. Extract from the online catalog. Order No.:

DATASHEET - ETR4-70-A. Delivery program. Timing relay, 2W, 0.05s-100h, multi-function, VAC/DC, potentiometer connection

FRONT 2,5-H/SA 5. Extract from the online catalog. Order No.:

MC 1,5/ 4-ST-3,5. Extract from the online catalog. Order No.:

New Products Catalogue 2009 Safety Relays ESR5

DATASHEET - ETR4-51-A. Delivery program. Technical data General. Timing relay, star-delta, 50 ms, 1W, 3-60s, VAC/DC

SLKK 5. Extract from the online catalog. Order No.:

Electronic timer CT-AWS Impulse-OFF with 1 c/o contact Data sheet

Safety Technique. SAFEMASTER Emergency Stop Module With Time Delay BH 5928, BI 5928

Safety Technique. Emergency Stop Module With Time Delay BH 5928, BI 5928

AF AF V50/60HZ-DC Contactor. General Information. Ordering. Popular Downloads. Dimensions. Technical AF

Datasheet - PROTECT-IE-02

* Short-circuit detection at On pushbutton. Applications. Indication. S M6801_a S11 A3 S12 S21 S23 S22 S (+)

Online data sheet UE10-3OS3D0 UE10-3OS SAFETY RELAYS

MKKDSH 3/ 2. Extract from the online catalog. Order No.:

UTTB 4. Extract from the online catalog. Order No.:

AKG 4 GNYE. Extract from the online catalog. Order No.:

Measuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC

SMKDS 2,5/ 2-5,08. Extract from the online catalog. Order No.:

UTTB 2,5. Extract from the online catalog. Order No.:

QUINT-PS-24DC/24DC/10

MKDSN 1,5/ 4-5,08. Extract from the online catalog. Order No.:

Electronic timer CT-TGD.22

No-wear isolation of potentials in terminal block design

Electronic timer CT-SDE

MVSTBR 2,5/ 2-ST. Extract from the online catalog. Order No.:

KDS10/SO. Extract from the online catalog. Order No.:

This data sheet is only valid in association with the IL SYS INST UM E user manual.

QUINT-PS AC/24DC/40

MKDS 3/ 4. Extract from the online catalog. Order No.:

3.5 mm contact pin pitch 1 Pole 12 A PCB direct or via socket

Transformers, Power Supply Units and Socket Outlets

MVSTBW 2,5/ 5-ST. Extract from the online catalog. Order No.:

EMD-FL-3V Phase Voltage Monitoring Relay INTERFACE. Data Sheet. Description

38 Series - Relay interface modules A. Features /

KDSP 4. Extract from the online catalog. Order No.:

48 SERIES. Relay interface modules 8 A CO forcibly guided contacts relay interface modules,15.8 mm wide Type 48.12

PHOENIX CONTACT - 09/2009

MINI-PS AC/24DC/1.3

AC/DC. Monitoring Technique. VARIMETER IMD Insulation monitor RN 5897/300

V2IM10AL10 Art.Nr.: V2IM10AL10P Art.Nr.: Control element. Tripping delay. Function selector. Status indication 24...

E-STOP relays, safety gate monitors

Electronic timer CT-EBE Flasher starting with OFF, 1 c/o (SPDT) contact

MINI MCR-SL-UI-I-LP-NC

Low profile safety relay with forcibly guided double contacts FEATURES. Relay height, 14.5mm. 4a2b

Output of three-phase motors at 50 Hz and 400 V

MSTB 2,5/ 4-ST. Extract from the online catalog. Order No.:

Electronic timer CT-SDD.22

Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800)

CP-T range Product group picture

02/11/2015

02/11/2015

Electronic timer CT-YDE Star-delta change-over with 1 c/o (SPDT) contact

2 Pole CO, 8 A Plug-in 2 CO (DPDT) 1 CO (SPDT) 8/15 16/25* 250/ /400 2,000 4, /0.5/ /0.5/ (5/5) 300 (10/5)

V2UM230V10 Art.Nr.: V2UM230V10P Art.Nr.: Control elements. Tripping delay. Function selector. Status indication 230 V AC/DC

MSTB 2,5/ 3-ST. Extract from the online catalog. Order No.:

Electronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet

E-STOP relays, safety gate monitors

Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multifunction Types DPC71, PPC71

QUINT-PS/ 3AC/24DC/10

Voltage monitoring relay CM-EFS.2 For single-phase AC/DC voltages

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

UNO-PS/1AC/24DC/150W. Primary-switched power supply unit. Data sheet. 1 Description

Positive-guided relay outputs: 8 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Three-phase monitoring relay

STEP-UPS/24DC/24DC/3. Uninterruptible power supply. Data sheet. 1 Description. Features

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents

Type: EASY719 AC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 115/230 V AC. Description

MACX MCR-EX-SL-RPSSI-I-UP(-SP)

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multifunction Types DPC01, PPC01

PHOENIX CONTACT - 06/2008. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

Current monitoring relays CM-SRS.1 For single-phase AC/DC currents

38 Series - Relay Interface Modules A

RE17RCMU off-delay timing relay - 1 s..100 h V AC - 1 OC

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

Model Number Structure. Ordering Information. Solid-state Power OFF-delay Timer H3DE-H. Model Number Legend. List of Models

Thermistor motor protection relays

Electronic timer CT-MFS.21

QUINT-PS/ 3AC/24DC/40

Transcription:

Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) Safety relay for emergency stop and safety door monitoring up to SIL 3 or Cat. 4, PL e according to EN ISO 13849, automatic or manual activation, 2 N/O contacts with dropout delay of 0.1 s to 30 s, plug-in screw connection terminal block Product Features aximum of 3 undelayed and 2 dropout delay contacts anually monitored and automatic activation Up to Cat. 3/4 and PL d/e according to ISO 13849-1, SILCL 3 according to IEC 62061, SIL 3 according to IEC 61508 For emergency stop and safety door monitoring, plus evaluation of light grids (suitable light grids available on request) Protective labels to prevent manipulation of the set time (PSR-ESD-300) or electronic protection against manipulation (PSR-ESD-30) Single and two-channel control Fixed delay times of 0.1 s... 300 s Key commercial data Packing unit 1 pc Weight per Piece (excluding packing) 200.0 GR Custom tariff number 85371099 Country of origin Germany Technical data Note Utilization restriction EC: class A product, see manufacturer's declaration in the download area Dimensions Width Height 22.5 mm 99 mm 12/22/2014 Page 1 / 8

Technical data Dimensions Depth 114.5 mm Ambient conditions Ambient temperature (operation) -20 C... 45 C Ambient temperature (storage/transport) -40 C... 70 C ax. permissible relative humidity (operation) 75 % ax. permissible humidity (storage/transport) 75 % Input data Nominal input voltage U N 24 V DC Input voltage range in reference to U N 0.85... 1.1 Typical input current at U N 75 ma DC Voltage at input/start and feedback circuit approx. 24 V DC Typical response time 150 ms (onitored/manual and auto-start) Typical release time 20 ms (undelayed contacts) 100 ms (delayed contacts) Typical release time range 0.1 s... 30 s Recovery time 330 ms (Restart) 1 s (Electric torque) Status display LED K1/K2 and K3(t)/K4(t), green ax. permissible overall conductor resistance 500 Ω (Input and reset circuit at U N ) Output data Contact type 2 undelayed enabling current paths 2 enabling current paths delayed Contact material AgSnO 2 inimum switching voltage aximum switching voltage Limiting continuous current Inrush current, minimum aximum inrush current Sq. Total current Interrupting rating (ohmic load) max. aximum interrupting rating (inductive load) 15 V AC/DC 250 V AC/DC 6 A (N/O contact) 25 ma 6 A 120 A 2 (see to derating) 144 W (24 V DC, τ = 0 ms) 288 W (48 V DC, τ = 0 ms) 90 W (110 V DC, τ = 0 ms) 88 W (220 V DC, τ = 0 ms) 1500 VA (250 V AC, τ = 0 ms) 42 W (24 V DC, τ = 40 ms) 12/22/2014 Page 2 / 8

Technical data Output data Switching capacity min. Output fuse 33 W (48 V DC, τ = 40 ms) 25 W (110 V DC, τ = 40 ms) 23 W (220 V DC, τ = 40 ms) 0.4 W 10 A gl/gg NEOZED (N/O contact) General Relay type Electromechanically forcibly guided, dust-proof relay. echanical service life Approx. 10 7 cycles ounting type DIN rail mounting Degree of protection IP20 in. degree of protection of inst. location IP54 ounting position any Category according to EN 13849-1 4 Stop category 0 (undelayed contacts) 1 (delayed contacts) Designation Air and creepage distances between the power circuits Standards/regulations DIN EN 60947-1 Rated surge voltage/insulation 4 kv / basic insulation Rated insulation voltage 250 V Pollution degree 2 Surge voltage category II Connection data Conductor cross section solid min. 0.2 mm² Conductor cross section solid max. 2.5 mm² Conductor cross section stranded min. 0.2 mm² Conductor cross section stranded max. 2.5 mm² Conductor cross section AWG/kcmil min. 24 Conductor cross section AWG/kcmil max 12 Stripping length 7 mm Screw thread 3 Connection method Screw connection Classifications ecl@ss ecl@ss 4.0 27371102 12/22/2014 Page 3 / 8

Classifications ecl@ss ecl@ss 4.1 27371102 ecl@ss 5.0 27371901 ecl@ss 5.1 27371901 ecl@ss 6.0 27371819 ecl@ss 7.0 27371819 ecl@ss 8.0 27371819 ETI ETI 2.0 ETI 3.0 ETI 4.0 ETI 5.0 EC001449 EC001449 EC001449 EC001449 UNSPSC UNSPSC 6.01 30211901 UNSPSC 7.0901 39121501 UNSPSC 11 39121501 UNSPSC 12.01 39121501 UNSPSC 13.2 39121501 Approvals Approvals Approvals UL Listed / GOST / cul Listed / Functional Safety / culus Listed Ex Approvals Approvals submitted Approval details UL Listed 12/22/2014 Page 4 / 8

Approvals GOST cul Listed Functional Safety culus Listed Drawings Circuit diagram A1 S11 S12 13 23 37 47 = = Logic K1 K2 K3 K4 A2 S34 S35 S21 S22 14 24 38 48 12/22/2014 Page 5 / 8

Circuit diagram L+ (L1) L1 L2 L3 Emergency stop S1 ( ) ( ) A1 S11 S12 S21 S22 <0,1 13 23 37 (Clock) ( ) (Clock) ( ) 0,5 1 3 PSR-ESD-30 5 10 20 A2 S34 S35 30 14 24 38 47 48 S2 Reset K7 K7 Brake (N) Two-channel emergency stop monitoring 12/22/2014 Page 6 / 8

Circuit diagram L+ (L1) L1 L2 L3 Light grid Receiver Transmitter OSSD 1 OSSD 2 ( ) ( ) A1 S 11 S 12 S 21 S 22 <0,1 13 23 37 (Clock) ( ) (Clock) ( ) 0,5 1 3 PSR-ESD-30 5 10 20 A2 S 34 S 35 30 14 24 38 47 48 S2 Reset (N) Light grid monitoring 12/22/2014 Page 7 / 8

Circuit diagram L+ (L1) L1 L2 L3 Safety door S1 ( ) ( ) A1 S11 S12 S21 S22 <0,1 13 23 37 (Clock) ( ) (Clock) ( ) 0,5 1 3 PSR-ESD-30 5 10 20 A2 S34 S35 30 14 24 38 47 48 S2 Reset (N) Two-channel safety door monitoring Phoenix Contact 2014 - all rights reserved 12/22/2014 Page 8 / 8