How to order. Payment options. Delivery options. Online acatalog. By phone + (44) By fax + (44)

Similar documents
HO7RN-F 450/750V BS EN Highly Flexible Rubber Cable

CY CONTROL FLEXIBLE PVC INSULATED / TINNED COPPER WIRE BRAID (TCWB) / PVC SHEATHED

Armoured Power and Control Cables to BS7917

Armoured Power and Control Cables Fire Resistant

SY CONTROL FLEXIBLE PVC INSULATED, BEDDED AND SHEATHED WITH GALVANISED STEEL BRAID

Armoured Power and Control Cables to BS6883

Welding Cables Rubber Insulated

ÖLFLEX. Lift & Crane Cable LIFT & CRANE CABLE

Armoured Instrumentation Cables to BS6883

ABOUT US ABOUT US 1 CRANE CABLES

CIR (Crush & Impact Resistant) VFD Power Cable

SINGLE CORE CABLE-2491X PVC H05V-K CABLE 300/500V

Selection table for flat & ribbon cables

CABLES AND WIRES

Y-CY-JZ flexible, CU-screened, transparent, EMC-preferred type, meter marking

Kerman & Kavian Cable Industries ( KCI )

VSD CABLES. KSXCY Series MDXCY Series HDXCY Series FDXCY Series P: (09)

MEDIUM VOLTAGE

H07RN-F BS EN Flexible Rubber Cable

FLEXIBLE MULTI CORE CABLES

High Temperature Flexible Control Cable

GEXOL WORLD CLASS OIL & GAS CABLES

Wire and Cable. 99 Wire Dual Wall 120ºC rated, Modified Polyester Low fire hazard wire and cable. Features & Benefits

WIRE & CABLE. 99 Wire Low fire hazard wire and cable

Instrumentation Cables

Content HYBRID AND SPECIAL CABLES G 1. for the application on marine engines... page. : especially for use in rail vehicles. ❿! Applications...

Tri-Rated Flexible PVC Equipment Wire

ENERGY CORDAFLEX (SMK) (N)SHTOEU Low Voltage Reeling Cable

P Low Voltage Catalogue Cables Australia Powering your Project

Power Cables and their Application

Marine Cables General Catalogue

EXTREMELY LOW MAGNETIC FIELD (ELMF) XLPE INSULATED CABLES, TYPE N2XY/FR1 0.6/1 KV

WIRE & CABLE FILS ET CÂBLES ALAMBRES Y CABLES. 63 Technical information. 64 Primary Wire. 66 Brake Cable & Portable Extension Cable

List Price w.e.f. 02nd January, 2018

OFFSHORE CABLES GENERAL CATALOGUE. Offshore Cables. technergy INTEGRATED CABLING SOLUTIONS

n 100% EMI Emission Containment n Designed for Longer Service Life n Highly Flexible

Screened servo cable with PUR outer sheath for highly dynamic power chain application - certified

VFD CABLES 100% EMI CONTAINMENT HIGHLY FLEXIBLE & DURABLE

Spec wire. Performance Wire and Cable

Electric cables. Cranes

VFD CABLES 100% EMI CONTAINMENT FOR INDUSTRIAL APPLICATIONS

INTRODUCTION NUHAS OMAN QUALITY & RELIABILITY.

CABLES FOR MOTION CONTINUOUS-BENDING HI-FLEX ELECTRICAL CABLES TOTALTRAX TURN-KEY SYSTEMS PRE-ASSEMBLED CABLES STRAIN RELIEF DEVICES

Railway products. Edition 2014

HYDROFIRM(T) EMV-FC S1BC4BF KTW/W270 Drinking Water Application, shielded version ENERGY. Exclusive Authorised UK Distributor

Cables. Cables. Power. Fire Resistant WILSON CABLES PRIVATE LIMITED. Distributed By :

Coaxial Cables Coax Serie. HF Steckverbinder für Mobilfunk-Anwendungen. in Bulk Rings or on Cable Drums

TIGER BRAND MINING CABLES

SPEC 44. Wire and cable

Medium Voltage Power Cables

COPPER + LWL RAW CABLES

DLO Flexible Power Cable

TRAXLINE CABLES FOR MOTION

ÖLFLEX FORTIS 55 Highly Flexible and Extremely Oil-Resistant Tray Cable; -40 C Flexible/-55 C Stationary

A NEW WAVE OF DATA AND ENERGY MARINE AND OFFSHORE CABLES

EcoCable and EcoFlex Cable. Smaller. Lighter. Tougher. 100% Recyclable.

WIRE AND CABLE SECTION M WIRE AND CABLE. TEW / TEWN and TR-64 Wire. SPT1 / SPT2 / SEW1 AND SEW2 Wire. SVT / SJT / SO AND SOOW Cords

EcoCable and EcoFlex Cable. Smaller. Lighter. Tougher. 100% Recyclable.

SUBMERSIBLE PUMP CABLES

Contents. Introduction 3 Cable Components 4 Cable Handling 8 Health, Safety and Environment 9 Quick Reference Guide 10 Underground Mining - Coal 12

02 WIRE AND CABLE WIRE AND CABLE FILS ET CÂBLES ALAMBRES Y CABLES. Primary Wire Dispenser

Photo: HELUKABEL. Motor, Servo & Feedback Cables D 1

WIRE & CABLE. 55 Wire High performance wire and cable

Motor, Servo & Feedback Cables

EcoCable and EcoFlex Cable. Smaller. Lighter. 100% Recyclable.

RHEYFIRM (RS)-FLAT R-(N)TSFLCGCWOEUS with / without optical fibre elements 3.6/6 kv up to 8.7/15 kv in line with DIN VDE 0250 part 813

High Temperature Flexible Control Cable OLFLEX

TPE-INSULATED CABLES TPE-INSULATED CABLES. Products. TPE - Cables HEW-KABEL/CDT

Detailed Specifications & Technical Data

TwenCombi Cat-5E FTP(3x) - Coax 9 - EIBA - tube PE 5 mm

INDUSTRIAL CABLES DESIGNED FOR LONGER SERVICE LIFE IN HARSH ENVIRONMENTS

Wire and Cable. 55 Wire Single or Dual Wall 200ºC rated, XLETFE High performance wire and cable. Features & Benefits

14 AWG 2 AWG: 600 Volt

For tough, seaworthy wire

Lutze Inc. Flexible Control Cables USA Selection Guide V. 2.6

Conductors and Raceway Design

CCW. Continuously Corrugated Welded Cable. Armored Cable for Hazardous Locations

OLFLEX. Flexible Tray Cable MARYLAND METRICS. LAPP products are available from

Industrial Ethernet OPT cable manufactured for Petrol Forecourt Applications.

Product information. Marine, Oil & Gas.

Notes 3 Explanatory Information 4-10

For information transmission at dry and moist production sites, in and under plaster, outdoors for fixed installation.

RAXLINE TPE TOP FLEXDESIGN TPE CABLES UP TO 10 MILLION MOTION CYCLES UP TO 1000 M TRAVEL LENGTH DOWN TO 5 Ø

EDS LV WAVEFORM MAINS CABLE RATINGS

Creating. There is one basic question every customer needs to address when creating custom

Standard Technical Specifications for Electrical Works CABLES AND ACCESSORIES. 11 kv XLPE-Insulated Three-Core Underground Cables


1.1_KV PVC insulated PVC sheathed multicore Aluminium Cable (armoured & unarmoured)

Ship Hybrid Cable DL 58 5 x UC1500 SS22 2x SM BendBright XS G.657.A2 6x MM MaxCap-BB-OM4

15 years of experience

DOWNSTREAM POWER, CONTROL & INSTRUMENTATION CABLES

Caledonian. VG Series. Caledonian Navy Cables.

Detailed Specifications & Technical Data

EXTRA-PREMIUM GRADE PVC JACKET FOR EXTENDED CABLE LIFE. 24 AWG (0,23mm 2 ), 7/32 (7x0,20mm), Insulation Thickness: 0.010" (0,25mm)

TYGADURE FOR EXTREME APPLICATIONS

CORFLEX VFD CORFLEX VFD Part Number: Drive Cable

Innovative Eldra Solar Cabling System SOLINQ total system for solar cabling Sustainability

RHEYCORD (RTS) (N)SHTOEU-J in line with DIN VDE 0250 part 814

kv: medium voltage reeling cable with fibreoptics

STANDARD SPECIFICATION FOR INSTRUMENT CABLES AND RELATED ACCESSORIES DOCUMENT NO : 44-LK /J.02/0014-A4

Transcription:

S P E C I A L I S T C A B L E S U P P L I E R S

How to order Online / acatalog By phone + (44) 1628 850024 By fax + (44) 1628 648068 By email info@csecables.com Our hours Monday to Friday, 8am-5.30pm Payment options Payments can be made using a wide selection of debit or credit cards, or you can apply for a credit account. Please ask your CSE representative for an account application form. You can also pay by pro forma which can be paid by cheque, card, CHAPS or BACS payment. Delivery options CSE Cables aim to get your order to you as quickly as we can and offer a range of delivery options to suit your requirements, including: Next working day delivery Same day delivery Special delivery Free local deliveries and orders of over 250 are carriage paid to UK mainland CSE have a service to suit you!

Export Sales Our export sales specialists have been with CSE for several years and built up extensive knowledge and expertise of a wide range of cables for the export market. We understand the needs of our customers and achieve this by working closely with out freight forwarders so we can deliver your cables in perfect condition, on time and to budget. You can contact our export team directly by: By phone + (44) 1628 648067 By Skype cse_export By email export@csecables.com Contents Flexible Rubber Cables Flexible Control Cables Data/Telephone Cables Power Cables Fire Alarm Cables High Temperature Cables 6-24 25-33 34-47 47-71 72-76 77-87 Robotics and Crane Cables 88-103 Entertainment Cables 104-107 Technical Cables 108-136 Index 137-138 3

About CSE Cables Ltd CSE Cables was established in 2007 as an offshoot of Control Systems and Equipment Ltd and has been trading independently since that time. After a company re-structure, CSE Cables Ltd coenced trading from April 01 2011 as a group company having acquired relevant assets from the holding company. Specialising in all types of Industrial cable and with a customer base extending to Europe and beyond, CSE Cables Ltd s service offering includes the ability to deliver specialist cable on short lead times and at extremely competitive prices. Corrina Butler (Managing Director) and John Le Grys (Financial Director) are continuing to build a team of sales professionals offering a technical, friendly, competent service to clients in all types of industry. The current sales team boast over 50 years experience in the cable industry between them. Customers requiring Low Voltage Electrical Equipment and electrical accessories can be conveniently supplied by our sister company CSE Industrial Electrical Distributors Ltd. Credit facilities with one company may extend to the other facilitating a one-stop solution to many customer types. You can contact them directly by: By phone + (44) 1628 529448 By email info@cse-distributors.co.uk Website www.cse-distributors.co.uk 4

Bespoke Cables CSE Cables can offer any cable to your specification with low minimum order requirements and short delivery times. We can also supply specialist composite cables combining data, power cable and control cable. Simply contact our sales team: By phone + (44) 1628 850024 By Skype csecables By fax + (44) 1628 648068 By email info@csecables.com CSE Cables supplies only genuine cable and recognises the Industry led Approved Cables Initiative. The organisation aims to investigate and address the issues of unsafe, nonapproved and counterfeit cables in the UK marketplace. 5

0361TQ Welding Cable FLEXIBLE RUBBER CABLES Application Welding cable suitable for the transmission of high currents from the welding apparatus to the welding tool. Suitable for flexible use under adverse conditions such as automobile manufacturing, conveyors and assembly lines. Also for use in machine tool and ship manufacturing. Technical Information Conductor: Class 6 - extra flexible plain copper conductors to BS EN 60228: 2005 (previously BS6360) flexible class 5 for 120 2 and above Seperator: PETP (Polyethylene Terephthalate) Insulation: EPR (Ethylene Propylene Rubber) Sheath: CSP (Chlorosulphonated Polyethylene) - BS638 Sheath Colour: Orange, yellow or black Voltage Rating: 100V (450V for non-welding applications if protected from mechanical damage) Operating Temperature: Maximum: 85 C Minimum Flexing: -20 C Minimum Bending Radius: 6 x Ø Current Ratings Typical guidance values for different welding processes are as follows: Fully automatic Welding: 100% Semi-automatic Welding: 65% - 85% Manual Welding: 30% - 60% Very infrequent or Occasional Welding: 20% Correction Factors Cable operating temperature also varies according to the prevailing ambient temperature. These cables are designed to give optimum performance up to an operating temperature of 85 C at an ambient temperature of 25 C. The reduction factors for increased ambient temperature are: Ambient Temperature: 30 C 35 C 40 C 45 C 50 C 55 C Correction Factor: 0.96 0.91 0.87 0.82 0.76 0.79 Flexible aluminium conductors are available upon request. Size 2 Nominal overall diameter Weight 16 11.5 230 25 13 315 35 14.5 410 50 17 580 70 19.5 800 0361TQ Welding Cable 95 22 1,050 120 24 1,400 150 25.5 1,360 185 27.9 1,944 240 31.5 2,534 6

318TQ Cable Application Flexible chords suitable for domestic use. Technical Information Conductor: Insulation: Outer Sheath: Sheath Colour: HOFR: Voltage Rating: Operating Temperature: Minimum Bending Radius: Standards: Class 5 - flexible tinned annealed copper conductors EPR (Ethylene Propylene Rubber) CSP (Chlorosulphonated Polyethylene) Black or white Heat and oil resistant Flame retardant 300/500V grade to BS6500 (where applicable) Maximum: 85 C Minimum Flexing: -20 C 6 x Ø for cables not exceeding 25 8 x Ø for cables exceeding 25 BS 6500: flexible electric cables for use with appliances and equipment intended for domestic, office and similar environments BS 7919: flexible electric cables for use with appliances and equipment intended for industrial and similar environments. FLEXIBLE RUBBER CABLES Conductor Identification Single Core: Two Core: Three Core: Four Core: Five Core: Six Core and Above: Black Brown and blue Brown, blue and green/yellow Brown, grey, black and green/yellow Brown, blue, black, grey and green/yellow White insulation with black numerals Size 2 Nominal overall diameter Weight Single Core 3181TQ 0.5 3.8 19 0.75 4.0 23 1.0 4.2 28 1.5 4.9 38 2.5 5.5 41 4 6.3 73 2 Core 3182TQ 0.5 6.1 59 0.75 6.5 66 1.0 7.1 79 1.5 8.7 120 2.5 10.1 170 4 11.9 235 3 Core 3183TQ 0.5 6.5 65 0.75 7.1 80 1.0 7.6 94 1.5 9.3 140 318TQ Cable 7

318TQ Cable FLEXIBLE RUBBER CABLES Size 2 Nominal overall diameter Weight 3 Core 3183TQ 2.5 10.8 200 4 12.7 285 4 Core 3184TQ 0.75 7.7 96 1.0 8.2 113 1.5 10.3 174 2.5 12.0 252 4 14.1 355 5 Core 3185TQ 0.75 8.6 115 1.0 9.2 140 1.5 11.5 195 2.5 13.1 290 4 15.4 417 6 Core 3186TQ 0.75 9.6 135 1.0 10.2 171 1.5 12.7 235 2.5 14.7 340 7 Core 3187TQ 0.75 10.4 170 1.0 11.1 201 1.5 13.6 366 2.5 15.8 424 8 Core 3188TQ 0.75 11.3 175 1.0 12.3 244 1.5 15.2 315 2.5 17.8 465 9 Core 3189TQ 0.75 12.4 201 1.0 13.2 268 1.5 16.6 333 2.5 119.4 490 10 Core 31810TQ 0.75 12.4 215 1.0 13.2 286 1.5 16.6 360 2.5 19.4 530 For current ratings refer to IEE Regulations tables 4F1 and 4F2 to 4F3 on pages 122 to 128. 8

638TQ Cable Application Very heavy duty flexible trailing cable ideal for onsite applications where frequent flexing, trailing and heavy duty handling is required for portable or mobile equipment. Technical Information Conductor: Insulation: Sheath: Sheath Colour: HOFR: Voltage Rating: Operating Temperature: Minimum Bending Radius: Class 5 - flexible tinned annealed copper EPR (Ethylene Propylene Rubber) CSP (Chlorosulphonated Polyethylene) Black Heat and oil resistant Flame retardant 450/750V grade to BS6007 (where applicable) Maximum: 85 C Minimum flexing: -20 C 6 x Ø for cables not exceeding 25 8 x Ø for cables exceeding 25 FLEXIBLE RUBBER CABLES Conductor Identification 6381TQ - Single Core: Black 6382TQ - Two Core: Brown and blue 6383TQ - Three Core: Brown, blue and green/yellow 6384TQ - Four Core: Brown, blue, black and green/yellow 6385TQ - Five Core: Brown, blue, 2 black and green/yellow 6386TQ - Six Core and Above: White insulation with black numerals Size 2 Diameter over conductor RT of insulation Diameter over core Nominal overall diameter Weight Single Core 6381TQ 4 2.6 1.0 4.7 7.8 105 6 3.6 1.0 5.7 9.0 130 10 4.6 1.2 7.1 10.8 200 16 5.7 1.2 8.2 12.1 275 25 7.1 1.4 10.0 14.1 400 35 8.5 1.4 11.4 15.9 520 50 10.3 1.6 13.6 18.5 730 70 12.4 1.6 15.7 21.0 980 95 14.5 1.8 18.2 23.9 1,270 120 16.0 1.8 19.7 25.8 1,570 150 18.0 2.0 22.1 28.6 1,960 185 20.0 2.2 24.5 31.5 2,380 240 23.0 2.4 27.9 35.1 3,100 300 26.0 2.6 31.3 38.7 3,790 400 30.0 2.8 35.7 43.5 4,880 500 33.5 3.0 39.6 47.8 6,070 630 37.0 3.0 43.1 51.5 7,460 9

638TQ Cable FLEXIBLE RUBBER CABLES Size 2 Two Core 6382TQ Nominal diameter over laid up cores Nominal overall diameter Weight 4 9.5 13.2 275 6 11.5 15.6 370 10 14.3 20.6 690 16 16.5 23.3 910 25 20.1 27.4 1290 Three Core 6383TQ 4 10.2 14.1 335 6 12.3 16.6 450 10 15.4 22.1 835 16 17.7 24.8 1,120 25 21.6 29.3 1,600 35 24.6 32.9 2,080 50 29.4 38.5 2,890 70 33.9 43.6 3,850 95 39.3 50.0 4,970 120 42.5 53.9 6,350 150 47.7 59.9 7,700 185 52.9 65.9 9,350 240 60.3 74.7 1,200 300 67.6 83.2 14,910 Four Core 6384TQ 4 11.4 15.5 420 6 13.8 18.5 565 10 17.2 24.1 1,020 16 19.8 27.1 1,380 25 24.2 32.5 2,140 35 27.6 36.5 2,610 50 32.9 42.6 3,650 70 38.0 48.6 4,880 95 44.0 56.0 6,390 120 47.7 59.9 7,750 150 53.6 66.8 9,780 185 59.3 73.5 11,900 240 67.6 83.2 15,330 300 75.8 92.8 19,030 Five Core 6385TQ 4 12.7 17.2 515 Size 2 Five Core 6385TQ Nominal diameter over laid up cores Nominal overall diameter Weight 6 15.4 20.5 690 10 19.2 26.5 1240 16 22.2 30.1 1695 25 27.1 36.1 2470 35 30.9 40.5 3187 50 36.9 47.3 4450 70 42.6 54.0 5938 95 49.4 62.0 7924 Six Core 6386TQ 4 14.2 19.6 643 6 17.2 23.4 917 10 21.4 28.8 1,420 16 24.7 32.7 1,973 25 30.2 39.2 2,921 35 34.4 44.0 3,822 50 41.0 51.8 5,337 Seven Core 6387TQ 4 15.8 21.6 6 19.1 25.7 1,089 10 23.8 31.6 1,706 16 27.5 35.7 2,330 25 33.6 43.2 3,560 35 38.3 48.5 4,576 50 45.8 57.4 6,436 Eight Core 6388TQ 4 17.3 23.5 908 Ten Core 63810TQ 4 18.9 25.3 1,073 Twelve Core 63812TQ 4 19.6 26.2 1,183 Sixteen Core 63816TQ 4 22.1 29.3 1,505 Eighteen Core 63818TQ 4 23.6 31.0 1,687 Twenty Core 63820TQ 4 25.2 33.0 1,902 For current ratings refer to IEE Regulations tables 4F1 and 4F2 to 4F3 on pages 122 to 128. 10

657TQ Ship Wiring Application This unarmoured cable can be used for fixed wiring in ships and on offshore units. Technical Information Conductor: Class 2 - stranded tinned annealed copper conductors Insulation: EPR (Ethylene Propylene Rubber) Sheath: CSP (Chlorosulphonated Polyethylene) Sheath Colour: Black (2MAL SW4) HOFR: Heat and Oil resistant Flame retardant Oxygen Index: 32%, HCL 5% Voltage Rating: 600/1000V grade to BS6883 Type B (where applicable) Operating Temperature: -40 C to +85 C Conductor Identification White cores with black numerals. For individual conductor dimensions refer to Single core 6571TQ. BS6883, and subsequent amendments, are approved by Lloyd s Register of shipping. FLEXIBLE RUBBER CABLES Size 2 Maximum diameter over conductor Nominal overall diameter Weight Single Core 6571TQ 1.0 1.20 5.2 35 1.5 1.50 5.5 42 2.5 2.01 6.0 57 4 5.55 6.9 82 6 3.12 7.5 105 10 4.05 9.0 165 16 5.10 10.1 230 25 6.75 12.4 360 35 7.65 13.3 425 50 8.90 15.2 570 70 10.70 17.2 785 95 12.46 19.3 1,060 120 14.21 21.4 1,300 150 15.75 23.5 1,600 185 17.64 26.0 1,990 240 20.25 29.2 2,580 300 22.68 32.3 3,210 400 26.66 36.4 4,380 500 29.15 40.2 5,470 630 32.76 44.1 6,800 500 2 34.5 4,880 630 2 38.4 6,210 Size Nominal diameter over laid up cores Nominal overall diameter Weight Two Core 6572TQ 1.0 5.6 8.0 84 1.5 6.2 8.6 105 2.5 7.2 9.8 145 4 9.2 12.0 225 6 10.4 13.1 285 10 13.0 16.0 445 16 15.0 18.3 630 25 19.2 22.9 965 35 21.0 24.7 1,140 50 24.2 28.4 1,520 70 27.8 32.3 2,070 95 32.2 37.0 2,810 120 35.6 40.8 3,410 150 39.6 45.1 4,220 185 44.0 50.0 5,240 240 50.0 56.6 6,780 300 55.8 62.7 8,430 400 26.66 2.6 32.2 500 29.15 2.8 35.2 630 32.76 2.8 38.8 500 2 28.80 2.8 630 2 32.76 2.8 657TQ Ship Wiring Cable 11

657TQ Ship Wiring FLEXIBLE RUBBER CABLES Size 2 Nominal diameter over laid up cores Three Core 6573TQ Nominal overall diameter Weight 1.0 6.2 8.4 100 1.5 6.9 9.3 130 2.5 7.9 10.4 180 4 10.1 12.7 270 6 11.4 13.9 350 10 14.2 17.2 565 16 16.4 19.5 795 25 20.8 24.4 1,240 35 22.8 26.5 1,480 50 26.2 30.3 1,960 70 30.1 34.7 2,700 95 34.8 39.7 3,680 120 38.5 43.8 4,490 150 42.8 48.4 5,550 185 47.5 53.9 6,910 240 54.0 61.1 8,980 300 60.2 67.6 11,170 Four Core 6574TQ 1.0 7.0 9.3 145 1.5 7.8 10.1 155 2.5 9.0 11.4 215 4 11.4 13.9 335 6 12.9 15.4 445 10 16.0 18.9 700 16 18.4 21.7 1,010 25 23.5 25.8 1,570 35 25.7 27.8 1,880 50 29.5 32.0 2,510 70 33.9 36.2 3,490 95 39.2 42.1 4,780 120 43.4 45.8 5,830 150 48.0 50.5 7,210 185 53.4 56.2 8,960 Size 2 Nominal diameter over laid up cores Five Core 6575TQ Nominal overall diameter Weight 240 60.7 65.8 11,660 300 67.7 73.5 14,530 1.5 8.7 11.0 185 2.5 10.0 12.6 265 4 12.7 15.3 410 Six Core 6576TQ 1.5 9.6 12.2 220 2.5 11.1 13.7 315 4 14.1 16.7 475 Eight Core 6578TQ 1.5 10.5 13.3 295 2.5 12.3 15.3 398 4 15.4 18.5 606 Ten Core 65710TQ 1.5 12.6 16.2 260 2.5 14.6 17.7 519 4 18.4 21.7 800 Twelve Core 65712TQ 1.5 13.1 16.7 405 2.5 15.2 18.8 603 4 19.1 22.6 838 Sixteen Core 65716TQ 1.5 14.8 17.9 482 2.5 17.2 20.5 694 Twenty Core 65720TQ 1.5 16.8 20.1 597 2.5 19.5 23.0 875 Twenty Four Core 65724TQ 1.5 18.8 22.3 725 2.5 21.9 25.6 1,046 Thirty Core 65730TQ 1.5 20.1 23.6 873 2.5 23.4 27.1 1,270 12

658TQ Cable Application Designed for use in offshore environments where mechanical protection is required eg. for fixed wing in ships, drilling rigs and oil platforms. Technical Information Conductor Stranding: Class 2 - stranded tinned annealed copper IEC 60228/BS 6360 Insulation: EPR (Ethylene Propylene Rubber) Armour: GSWB (Galvanized steel wire braid) Sheath/Jacket: Low Smoke Halogen Free (LSHF) Type: SW4 Sheath Colour: Black Ref: 658TQ Standard: BS 6883 Voltage: 600/1000V Operating Temperature: Maximum: 85 C Minimum Bending: -25 C Conductor Identification White cores with black numbers FLEXIBLE RUBBER CABLES Size 2 Nominal diameter over laid up cores Nominal diameter over bedding Diameter of braid wire Nominal overall diameter Weight 6582TQ Galvanised Steel Wire Braid - Two Core 1.0 5.6 8.0 0.3 12.1 230 1.5 6.2 8.6 0.3 12.7 250 2.5 7.2 9.8 0.3 13.9 305 4 9.2 12.0 0.3 16.3 420 6 10.4 13.1 0.3 17.6 515 10 13.0 16.0 0.3 20.7 725 16 15.0 18.3 0.3 23.4 975 25 19.2 22.9 0.3 28.1 1,340 35 21.0 24.7 0.3 30.1 1,540 50 24.2 28.4 0.45 35.1 2,140 70 27.8 32.3 0.45 39.3 2,820 95 32.2 37.0 0.45 44.4 3,690 120 35.6 40.8 0.45 48.5 4,380 150 39.6 45.1 0.45 53.4 5,360 185 44.0 50.0 0.45 58.8 6,550 240 50.0 56.6 0.45 65.8 8,310 300 55.8 62.7 0.45 72.7 10,200 6583TQ Galvanised Steel Wire Braid - Three Core 1.0 6.2 8.4 0.3 12.5 245 1.5 6.9 9.3 0.3 13.4 280 2.5 7.9 10.4 0.3 14.7 360 4 10.1 12.7 0.3 17.0 475 6 11.4 13.9 0.3 18.4 586 658TQ Cable 13

658TQ Cable FLEXIBLE RUBBER CABLES Size 2 Nominal diameter over laid up cores 6583TQ Galvanised Steel Wire Braid - Three Core Nominal diameter over bedding Diameter of braid wire Nominal overall diameter Weight 10 14.2 17.2 0.3 22.1 860 16 16.4 19.5 0.3 24.6 1,150 25 20.8 24.4 0.3 29.8 1,640 35 22.8 26.5 0.45 33.1 2,030 50 26.2 30.3 0.45 37.2 2,640 70 30.1 34.7 0.45 41.9 3,480 95 34.8 39.7 0.45 47.6 4,650 120 38.5 43.8 0.45 52.0 5,540 150 42.8 48.4 0.45 57.9 6,770 185 47.5 53.9 0.45 62.9 8,310 240 54.0 61.1 0.45 70.6 10,680 300 60.2 67.6 0.45 77.9 13,100 6584TQ Galvanised Steel Wire Braid - Four Core 1.0 7.0 9.3 0.3 13.4 300 1.5 7.8 10.1 0.3 14.2 320 2.5 9.0 11.4 0.3 15.7 410 4 11.4 13.9 0.3 18.4 570 6 12.9 15.4 0.3 20.1 720 10 16.0 18.9 0.3 24.0 1,050 16 18.4 21.7 0.3 26.9 1,410 25 23.5 25.8 0.45 33.6 2,160 35 25.7 27.8 0.45 36.1 2,510 50 29.5 32.0 0.45 41.0 3,290 70 33.9 36.1 0.45 46.1 4,410 95 39.2 42.1 0.45 52.6 5,880 120 43.4 45.8 0.45 57.4 7,050 150 48.0 50.5 0.45 63.1 8,620 185 53.4 56.1 0.45 69.6 10,620 240 60.7 65.8 0.45 78.3 13,580 300 67.7 73.5 0.45 82.6 16,760 6585TQ Galvanised Steel Wire Braid - Five Core 1.5 8.7 11.0 0.3 15.6 370 2.5 10.0 12.6 0.3 17.4 470 4 12.7 15.3 0.3 20.3 680 6586TQ Galvanised Steel Wire Braid - Six Core 1.5 9.6 12.2 0.3 17.0 420 2.5 11.1 13.7 0.3 18.5 545 4 14.1 16.7 0.3 21.7 765 14

Size 2 Nominal diameter over laid up cores 6588TQ Galvanised Steel Wire Braid - Eight Core Nominal diameter over bedding Diameter of braid wire Nominal overall diameter Weight 1.5 10.5 13.3 0.3 18.1 545 2.5 12.3 15.5 0.3 20.5 735 4 15.4 18.5 0.3 23.7 1,000 658/12TQ Galvanised Steel Wire Braid - Twelve Core 1.5 13.1 16.7 0.3 21.7 685 2.5 15.2 18.8 0.3 24.0 919 4 19.1 22.6 0.3 28.2 1,240 658/16TQ Galvanised Steel Wire Braid - Sixteen Core 1.5 14.8 17.9 0.3 23.1 791 2.5 17.2 20.5 0.3 25.9 840 658/20TQ Galvanised Steel Wire Braid - Nineteen Core 1.5 15.7 18.7 0.3 23.9 871 2.5 18.3 21.5 0.3 26.9 1,190 658/21TQ Galvanised Steel Wire Braid - Twenty One Core 1.5 16.8 20.0 0.3 25.4 984 2.5 19.5 22.9 0.3 28.5 1.320 658/24TQ Galvanised Steel Wire Braid - Twenty Four Core 1.5 18.8 22.3 0.3 27.9 1,130 2.5 21.9 25.6 0.45 32.2 1,650 658/27TQ Galvanised Steel Wire Braid - Twenty Seven Core 1.5 19.3 22.7 0.3 28.3 1,210 2.5 22.4 26.0 0.45 32.6 1,760 FLEXIBLE RUBBER CABLES 15

H01N2-D and H01N2-E Welding Cable FLEXIBLE RUBBER CABLES Cable Application Welding cable suitable for connecting cable between the hand electrode and the welding apparatus. Suitable for flexible use under adverse conditions such as automobile and ship manufacturing conveyors welding robots assembly lines etc. This cable maintains its high flexibility even when exposed to inert gas, ozone, light, oil etc. Suitable for use in dry and moist rooms as well as for outdoor installation. Technical Information Conductor: Plain copper conductors Seperator: Polyester foil or tape Outer Sheath: Neoprene black Stranding H01N2-D: According to VDE 0295 class 5 Voltage: Working: 100V Test: 1000V Temperature Range: Flexing:-25 C to + 80 C Static: -40 C to +80 C Bending Radius: H01N2-D: 12 x Ø H01N2-E: 10 x Ø H01N2-E Crane and Welding Cable Number of cores and cross section 2 H01N2-D Outer diameter ca. Max O.D. Copper weight kg/100m Weight kg/100m 10.00 10.0 9.60 14.00 16.00 11.5 15.40 21.00 25.00 13.0 24.00 30.00 35.00 14.50 33.60 41.00 50.00 17.0 48.00 56.00 70.00 19.0 67.20 79.00 95.00 21.5 91.20 105 120.00 24.0 115.20 130.00 150.00 26.0 144.00 163.00 185.00 29.0 177.60 191.60 H01N2-E with extreme high flexibility 10.00 8.40 9.60 11.90 16.00 9.50 15.40 18.10 25.00 11.00 24.00 27.00 35.00 12.50 33.60 36.30 50.00 15.00 48.00 52.80 70.00 17.00 67.20 71.60 95.00 19.50 91.20 101.20 120.00 21.50 115.20 109.00 16

H05RR-F Cable Cable Application For connection of electrical appliances when exposed to low to medium mechanical stress in households and offices and for light utilities. Anywhere where there is minimal physical damage expected. Technical Information Conductor: Class 5 - fine copper wire strands manufactured to IEC 60228 (previously BS6360) Insulation: Rubber Cores: Coloured cores according to VDE 0293 More than 2 cores with one green/yellow earth conductor Outer Sheath: Rubber black Stranding: Fine copper wires plain or tinned Voltage: Working: 300/500V to BS7919 and BS6500 Test: 2000V Temperature Range: Flexing: -25 C to +60 C Static: -40 C to +60 C Bending Radius: Flexing: 15 x Ø Static: 6 x Ø FLEXIBLE RUBBER CABLES Conductor Identification Two Core: Three Core: Four Core: Five Core: Brown and blue Brown, blue and green/yellow Brown, grey, black and green/yellow Brown, blue, grey, black and green/yellow Size 2 Number of cores Nominal overall diameter Weight 0.5 2 7.8 53 0.75 2 8.2 63 1.0 2 8.8 77 1.5 2 10.5 115 2.5 2 12.5 165 0.5 3 8.2 62 0.75 3 8.8 78 1.0 3 9.2 90 2.5 3 13.0 195 0.75 4 9.6 94 1.0 4 10.0 110 1.5 4 12.5 170 2.5 4 14.0 245 0.75 5 11.0 110 1.0 5 11.5 130 1.5 5 13.5 195 2.5 5 15.5 290 For current ratings refer to IEE Regulations tables 4F1 A and B on pages 122 to 123. H05RR-F Cable 17

H07RN-F Cable (BS7919:2001) FLEXIBLE RUBBER CABLES The H07RN-F is designed primarily as a trailing cable for use in the supply of energy for portable or mobile equipment. Heavy duty Harmonized cables are not only robust but also extremely flexible. PCP neoprene is also oil and flame retardant. Typical applications of the H07RN-F cable include transformers, pumps, welders, grinders, temporary lighting cable and feed cables to heavy mobile equipment. Technical Information Stranding: Insulation: Sheath: Temperature Range: Ambient Temperature: Voltage: Class 5 - fine copper wire strands manufactured to IEC 60228 (previously BS6360) EPR (Ethylene Propylene Rubber) Black neoprene (PCP) outer sheath to BS7919:2001-25 C to +85 C 30 C Working: 450/750V Test: 3000V Operating Temperature: 60 C Minimum Bending Radius: 6 x Ø for cables not exceeding 25 Static: 8 x Ø for cables exceeding 25 flexing 15 x Ø Conductor Identification Single Core: Two Core: Three Core: Four Core: Five Core: Black Brown and blue Brown, blue and green/yellow Brown, black, grey and green/yellow Brown, blue, black, grey and green/yellow HO7RN-F Cable Core and size 2 Nominal O/Dia Weight 1 x 16.0 12.0 260 1 x 25.0 14.0 369 1 x 35.0 15.9 500 1 x 50.0 18.3 689 1 x 70.0 20.7 918 1 x 95.0 23.4 1,202 1 x 120.0 25.8 1,489 1 x 150.0 28.3 1,824 1 x 185.0 31.0 2,202 1 x 240.0 34.5 2,847 1 x 300.0 37.7 3,495 2 x 1.5 9.4 116 2 x 2.5 11.0 164 2 x 4.0 12.8 232 2 x 6.0 14.2 297 2 x 10.0 20.4 573 2 x 16.0 23.0 774 2 x 25.0 27.4 1,110 2 x 35.0 30.8 1,474 Core and size 2 Nominal O/Dia Weight 3 x 1.5 10.3 141 3 x 2.5 11.8 200 3 x 4.0 13.7 285 3 x 6.0 15.2 371 3 x 10.0 21.9 712 3 x 16.0 24.7 971 3 x 25.0 29.4 1,394 3 x 35.0 32.8 1,850 4 x 1.5 11.2 174 4 x 2.5 12.6 249 4 x 4.0 15.1 361 4 x 6.0 16.9 480 4 x 10.0 24.0 890 4 x 16.0 27.0 1,225 4 x 25.0 32.6 1,792 4 x 35.0 36.5 2,380 4 x 50.0 42.0 3,635 4 x 70.0 49.0 4,830 4 x 95.0 55.0 6,320 18

Core and Size 2 Nominal O/Dia Weight kg/ km 5 x 1.5 12.3 218 5 x 2.5 14.5 309 5 x 4.0 16.9 450 5 x 6.0 18.8 595 5 x 10.0 26.5 1,100 5 x 16.0 30.0 1,528 5 x 25.0 36.0 2,200 5 x 35.0 40.0 2,925 7 x 1.5 14.6 295 7 x 2.5 16.6 410 Core and Size 2 Nominal O/Dia Weight kg/ km 12 x 1.5 18.9 500 12 x 2.5 22.0 720 19 x 1.5 22.5 715 19 x 2.5 26.0 1030 24 x 1.5 25.0 900 24 x 2.5 29.0 1,350 27 x 1.5 29.0 1,100 27 x 2.5 33.0 1,521 37 x 1.5 29.8 1,300 37 x 2.5 36.0 1,900 For current ratings refer to IEE Regulations tables 4F1 A and B on pages 122 to 123. FLEXIBLE RUBBER CABLES 19

Round Neoprene Cable with Strainer FLEXIBLE RUBBER CABLES Cable Application For installation exposed to rough environmental conditions e.g. conveyor and hoisting equipment and building machinery. Application where weather proof cables in big lengths are used. Technical Information Conductor: Strainer: Insulation: Outer Sheath: HOFR: Core Marking: Voltage: Stranded bare copper Supporting core to relieve stress EPR (Ethylene Propylene Rubber) Black neoprene Flame retardant 1 to 5 cores: according to VDE 0293 (colour coded) 6 cores: number coded (JZ) Working: 500V Test: 3000V Temperature Range: Flexing:-25 C to + 80 C Static:-40 C to + 80 C Bending Radius: 12,5 x Ø Cores Cross section 2 Outer diameter Weight kg/100m 2 1 7.4 9.1 3 1 9.5 11.6 4 1 8.9 14.2 5 1 10.4 17.1 7 1 11.8 23 9 1 13.6 26.8 12 1 15.9 39 16 1 16.4 43 18 1 17.3 47.5 20 1 20.5 51 24 1 20.6 65 36 1 24.3 94 48 1 29.6 124.5 54 1 33 158 61 1 31.6 153 2 1.5 8 9.6 3 1.5 9.5 14.1 4 1.5 11.8 22 5 1.5 12 23 7 1.5 12.8 27 8 1.5 13.8 31 9 1.5 14.8 33.5 10 1.5 17 40.6 11 1.5 20.1 45.8 12 1.5 19 51 13 1.5 22.1 57.1 Cores Cross section 2 Outer diameter Weight kg/100m 15 1.5 23.6 59 18 1.5 19.4 63 19 1.5 21.7 67 24 1.5 22.4 82 42 1.5 28 137 2 2.5 9.7 14.3 3 2.5 10.2 17.3 4 2.5 11.3 24.2 5 2.5 12.4 28.9 7 2.5 14.8 28.9 8 2.5 16.6 45.1 9 2.5 18.9 54.2 12 2.5 21.9 71 16 2.5 24.4 81.3 18 2.5 24.9 88 24 2.5 26.4 120 36 2.5 33.3 173.7 4 4 17.2 40 5 4 16.8 43.3 4 6 18.8 52.4 5 6 19.2 56.9 4 10 21.8 72.5 5 10 24.6 92.3 4 16 25.4 102.8 5 16 28 126 20

Coil End Lead Cable BS6195 Cable Application Primarily designed for use as power leads for connection to coil winding motors. Coil end lead cable can also be used as panel wiring, especially in areas where resistance to heat and oil is required. The HOFR sheath is oil and varnish resistant. It is also used as an alternative to tri-rated and bi-rated cable in certain applications. Technical Information Conductor: Class 5 - flexible tinned annealed copper conductors to IEC 60228 Insulation: EPR-CSP (Composite Ethylene Propylene Rubber/Chlorosulphonated Polyethylene) Sheath: CPE (Chlorinated Polyethylene) rubber compound Sheath Colour: Black Separator: PET Tape Voltage Rating: A: 300/500 C: 600/1000 D: 1900/3300 E: 3800/6600 F: 6350/11000 Temperature Rating: -20 C to + 90 C Minimum Bending Radius: 4 x Ø Standards: BS6195 Type 4 FLEXIBLE RUBBER CABLES Conductor Size 2 Class Insulation radial thickness Voltage category () Maximum overall diameter Voltage category () Weight Voltage category A B C D E A C D E F A C D E F 0.5 5 0.8 1.4 - - - 3.3 4.5 - - - 12 17 - - - 0.75 5 0.8 1.4 - - - 3.5 4.7 - - - 16 21 - - - 1.0 5 0.8 1.4 - - - 3.7 4.9 - - - 19 24 - - - 1.5 5 0.8 1.4 - - - 4.0 5.2 - - - 25 30 - - - 2.5 5 0.9 1.4 2.8 - - 4.6 5.6 8.5 - - 37 41 76 - - 4 5 1.0 1.4 - - - 5.4 6.3 - - - 57 66 - - - 6 5 1.0 1.5 - - - 6.5 7.5 - - - 80 93 - - - 10 5 1.2 1.5 - - - 7.9 8.5 - - - 130 136 - - - 16 5-1.5 2.8 5.0 7.6-9.6 12.4 17.2 22.9-206 255 384 566 25 5-1.6 2.8 5.0 7.6-11.4 13.8 18.6 24.1-300 351 495 680 35 5-1.6 2.8 5.0 7.6-12.8 15.2 20.0 25.5-406 458 613 810 50 5-1.7 2.8 5.0 7.6-14.8 17.1 22.1 27.3-573 616 796 997 70 5-1.8 2.8 5.0 7.6-17.2 19.2 24.2 29.4-793 820 1,020 1,237 95 5-2.0 3.0 5.0 7.6-19.7 22.0 26.3 31.5-1,028 1,097 1,287 1,520 120 5-2.2 3.0 5.0 7.6-21.9 23.5 27.8 33.3-1,285 1,340 1,542 1,804 150 5-2.3 3.0 5.0 7.6-24.1 25.5 29.8 35.3-1,562 1,635 1,853 2,131 185 5-2.4 3.0 5.0 7.6-26.3 27.5 32.1 37.3-1,914 1,973 2,225 2,503 240 5-2.4 3.0 5.0 7.6-28.3 30.6 35.1 40.3-2,431 2,504 2,782 3,081 300 5-2.6 3.0 - - 33.0 33.8 - - - 30.24 3,098 - - 400 5-2.8 3.0 - - - 37.4 37.8 - - - 3948 4,045 - - 4 10.1 1.2 - - - - 12.7 - - - - 0.3 - - - - 6 11.4 1.2 - - - - 13.9 - - - - 0.3 - - - - 10 14.2 1.3 - - - - 17.2 - - - - 0.3 - - - - Coil End Lead Cable BS6195 21

Coil End Lead Cable BS6195 FLEXIBLE RUBBER CABLES Conductor Size 2 Class Insulation radial thickness Voltage category () Maximum overall diameter Voltage category () Weight Voltage category A B C D E A C D E F A C D E F 16 16.4 1.4 - - - - 19.5 - - - - 0.3 - - - - 25 20.8 1.6 - - - - 24.4 - - - - 0.3 - - - - 35 22.8 1.7 - - - - 26.5 - - - - 0.45 - - - - 50 26.2 1.8 - - - - 30.3 - - - - 0.45 - - - - 70 30.1 2.0 - - - - 34.7 - - - - 0.45 - - - - 95 34.8 2.2 - - - - 39.7 - - - - 0.45 - - - - 120 38.5 2.3 - - - - 43.8 - - - - 0.45 - - - - 150 42.8 2.5 - - - - 48.4 - - - - 0.45 - - - - 185 47.5 2.7 - - - - 53.9 - - - - 0.45 - - - - 240 54.0 2.9 - - - - 61.1 - - - - 0.45 - - - - 300 60.2 3.2 - - - - 67.6 - - - - 0.45 - - - - 22

NSHTÖU-J Drum Reeling Cable Cable Application Suitable for use as trailing cable in hoists, transporting machines, and conveyors. Suitable in dry, moist and wet rooms and for outdoor installation where continual reeling and unreeling of the cable happens. Technical Information Conductor: Class 5 - flexible tinned copper Earth Conductor: Green/yellow Core Insulation: Rubber Cores: Twisted in layers Core Marking: Up to 5 cores: colour coded in accordance to VDE 0293 7 cores and over: black with printed consecutive number coding Outer Sheath: Black made of neoprene with incorporated vulcanised fabric braiding Strand Structure: According to VDE 0295, class 5 or 6 Voltage: Working: 1000V Test: 3000V Temperature Range: -40 C to + 70 C Bending Radius Drums: 12.5 x Ø Reversing rolls: 15 x Ø FLEXIBLE RUBBER CABLES Cores Cross section 2 Outer diameter Copper weight kg/100m Weight kg/100m 4 1.5 14.6 5.8 29.5 5 1.5 15.6 8.1 34 7 1.5 17.6 11.5 42 12 1.5 21.3 19.6 63 18 1.5 24.8 27.1 89.5 24 1.5 28 39.2 110 30 1.5 30.3 43.2 134.5 42 1.5 35.2 63.3 177.3 4 2.5 16.2 9.9 37 5 2.5 18.6 12.4 49 7 2.5 20.8 18 61.5 12 2.5 24.9 30.8 89.5 18 2.5 28.2 45.1 119.5 24 2.5 33 61.6 156.5 30 2.5 34.6 7.1 183 45 2.5 43.8 112.8 286.3 4 4 19.3 15.8 52 5 4 20.5 20 64 4 6 21.7 24.1 69 5 6 23.2 31.7 85.5 4 10 25.9 40.4 102.5 5 10 27.8 52.8 120 4 16 29.1 64.2 130.5 5 16 31.7 84.4 174.5 4 25 34.4 100.5 207 4 35 38.6 141 274 NSHTÖU-J Drum Reeling Cable 23

NSHTÖU-J Drum Reeling Cable FLEXIBLE RUBBER CABLES Cores Cross section 2 Outer diameter Copper weight kg/100m Weight kg/100m 4 50 45 201 379 4 70 51 268.8 535.6 4 95 60.6 364.8 701.8 4 120 63.5 485.7 822 4 150 66.5 576 890.5 24

YY-PVC Cable Cable Application Used as connecting cable, as measuring, checking and control cable in machine tool manufacturing, plant engineering, conditioning systems, power stations and on assembly lines and production lines to meet stringent safety requirements. Suitable for fixed installation or flexible applications with unrestricted mobility without forced movement control and without exposure to tensile load. Can be installed in dry and moist rooms. LSHF versions are available for applications in public buildings/areas e.g. hospitals, airports schools etc. PUR versions are available where resistance to oils are required. See page 92. Technical Information Conductor: Earth Conductor: Insulation: Outer Sheath: Fine strands of plain copper conductor According to VDE 0295, class 5 or IEC 60228 Green/yellow in cables with more than 2 cores PVC core insulation black with continuous white figure imprint (coloured cores also available) Grey PVC (LSHF also available) Voltage: 300/500V Temperature Range: Flexing: -5 C to +80 C Static: -40oC to + 80 C Bending Radius: 15 x Ø flexing Standards: BS 6500, VDE 0250 FLEXIBLE CONTROL CABLES Number of cores and 2 per conductor Approx outer diameter in Approx weight 2 x 0.5 4.8 35 3 x 0.5 5.1 42 4 x 0.5 5.7 54 5 x 0.5 6.2 63 7 x 0.5 6.7 81 12 x 0.5 8.9 131 14 x 0.5 9.5 153 18 x 0.5 10.5 188 21 x 0.5 11.7 221 30 x 0.5 13.3 304 35 x 0.5 14.5 256 40 x 0.5 15.4 400 52 x 0.5 17.3 517 61 x 0.5 18.5 603 65 x 0.5 312 644 80 x 0.5 21.1 780 100 x 0.5 23.6 975 2 x 0.75 5.4 45 3 x 0.75 5.7 55 4 x 0.75 6.2 66 5 x 0.75 6.7 79 Number of cores and 2 per conductor Approx outer diameter in Approx weight 7 x 0.75 7.3 101 10 x 0.75 9.6 150 12 x 0.75 9.9 171 16 x 0.75 11.1 220 18 x 0.75 11.7 244 21 x 0.75 13.0 286 25 x 0.75 13.8 337 26 x 0.75 14.2 350 34 x 0.75 15.9 448 41 x 0.75 17.4 538 50 x 0.75 19.2 648 51 x 0.75 19.2 646 61 x 0.75 20.5 779 65 x 0.75 21.8 832 80 x 0.75 23.6 1,019 100 x 0.75 26.4 1,271 2 x 1.0 5.7 53 3 x 1.0 6.0 65 4 x 1.0 6.5 79 5 x 1.0 7.1 94 7 x 1.0 8.0 126 YY-PVC Cable 25

YY-PVC Cable FLEXIBLE CONTROL CABLES Number of cores and 2 per conductor Approx outer diameter in Approx weight 8 x 1.0 9.5 149 10 x 1.0 10.2 180 12 x 1.0 10.5 205 14 x 1.0 11.2 238 16 x 1.0 11.8 266 18 x 1.0 12.7 300 20 x 1.0 13.4 330 25 x 1.0 14.7 408 26 x 1.0 15.1 424 34 x 1.0 17.1 551 36 x 1.0 17.4 578 40 x 1.0 18.4 638 41 x 1.0 18.8 661 50 x 1.0 20.6 797 56 x 1.0 21.4 888 61 x 1.0 22.1 958 65 x 1.0 23.6 1033 80 x 1.0 25.3 1251 100 x 1.0 28.3 1560 2 x 1.5 6.3 68 3 x 1.5 6.7 84 4 x 1.5 7.2 104 5 x 1.5 8.1 128 7 x 1.5 8.9 166 8 x 1.5 10.6 197 10 x 1.5 11.6 243 12 x 1.5 12.0 279 14 x 1.5 12.7 323 16 x 1.5 13.4 361 18 x 1.5 14.4 407 21 x 1.5 15.7 469 25 x 1.5 16.9 560 26 x 1.5 17.3 582 32 x 1.5 18.7 704 34 x 1.5 19.4 746 41 x 1.5 21.3 895 50 x 1.5 23.5 1089 Number of cores and 2 per conductor Approx outer diameter in Approx weight 51 x 1.5 23.5 1061 61 x 1.5 25.2 1309 65 x 1.5 26.7 1398 80 x 1.5 28.8 1708 2 x 2.5 7.5 101 3 x 2.5 8.1 132 4 x 2.5 8.9 163 5 x 2.5 10.0 200 7 x 2.5 11.1 267 12 x 2.5 14.8 445 14 x 2.5 15.8 515 18 x 2.5 17.8 648 25 x 2.5 20.8 890 34 x 2.5 24.4 1208 50 x 2.5 29.4 1754 3 x 4.0 9.9 201 4 x 4.0 10.8 249 5 x 4.0 12.1 305 7 x 4.0 13.4 407 11 x 4.0 17.6 634 12 x 4.0 18.1 660 3 x 6.0 11.7 289 4 x 6.0 13.0 365 5 x 6.0 14.5 447 7 x 6.0 16.0 600 3 x 10.0 14.6 466 4 x 10.0 16.2 590 5 x 10.0 18.1 722 7 x 10.0 20.0 968 4 x 16.0 18.8 1,087 5 x 16.0 21.2 1,370 7 x 16.0 23.4 1,779 4 x 25.0 23.5 1,582 5 x 25.0 26.4 1,998 4 x 35.0 26.4 2,106 5 x 35.0 29.6 2,635 For current ratings refer to IEE Regulations table 4F3 A & B on pages 127 to 128. 26

SY Steel Wire Braid Cable Cable Applications Power control cable with galvanised steel wire braiding. Suitable for fixed installation or flexible applications. Used as measuring, checking and control cable in machine tool manufacturing, plant engineering, air conditioning systems, office equipment, data processing systems and on assembly lines and product lines. Can also be used as energy or connecting cable in dry and moist rooms to meet safety requirements. Due to the galvanised steel wire braiding, these cables can even be used under adverse operating conditions or when exposed to high mechanical strain. Technical Information Conductor: Plain annealed copper conductor to IEC 60228 class 5 Earth Conductor: Green/yellow in the outer layer Insulation: Black with continuous white figure imprint Bedding: PVC Overall Screen: Made of tinned steel wire braid Outer Sheath: Transparent PVC Voltage: 300/500V Temperature Range: Flexible: -5 C to + 70 C Static: -40 C to + 70 C Bending Radius: Flexing: 20 x Ø Static: 6 x Ø FLEXIBLE CONTROL CABLES Size 2 Nominal overall diameter Weight kg/ 2 x 0.5 8.3 91 3 x 0.5 8.6 99 4 x 0.5 9.1 113 5 x 0.5 9.7 129 7 x 0.5 10.3 150 12 x 0.5 12.4 214 18 x 0.5 14.3 298 25 x 0.5 16.8 400 30 x 0.5 17.7 454 35 x 0.5 19.9 585 41 x 0.5 21.5 671 50 x 0.5 21.9 694 60 x 0.5 24.2 895 2 x 0.75 9.0 85 3 x 0.75 9.3 116 4 x 0.75 9.8 133 5 x 0.75 10.5 155 7 x 0.75 11.2 182 12 x 0.75 13.7 266 18 x 0.75 16.2 388 25 x 0.75 19.1 521 30 x 0.75 19.6 572 35 x 0.75 21.4 684 Size 2 Nominal overall diameter Weight kg/ 50 x 0.75 26.4 1,050 60 x 0.75 24.8 909 2 x 1.0 9.3 101 3 x 1.0 9.5 126 4 x 1.0 10.1 146 5 x 1.0 10.8 171 7 x 1.0 11.5 203 12 x 1.0 14.3 314 18 x 1.0 16.7 441 25 x 1.0 19.7 594 30 x 1.0 20.3 658 35 x 1.0 22.1 786 50 x 1.0 25.9 1,070 60 x 1.0 27.7 1,240 2 x 1.5 9.8 114 3 x 1.5 10.1 145 4 x 1.5 10.8 171 5 x 1.5 11.6 202 7 x 1.5 12.4 242 12 x 1.5 15.9 394 18 x 1.5 18.6 553 25 x 1.5 21.9 746 30 x 1.5 23.0 850 SY Steel Wire Braid Cable 27

SY Steel Wire Braid Cable FLEXIBLE CONTROL CABLES Size 2 Nominal overall diameter Weight kg/ 35 x 1.5 24.6 990 50 x 1.5 29.2 1,380 60 x 1.5 30.8 1,570 2 x 2.5 11.0 143 3 x 2.5 11.4 193 4 x 2.5 12.3 232 5 x 2.5 13.2 277 7 x 2.5 14.4 353 12 x 2.5 18.8 575 18 x 2.5 22.0 818 25 x 2.5 26.2 1,130 30 x 2.5 27.5 1,290 35 x 2.5 29.8 1,540 50 x 2.5 34.7 2,060 60 x 2.5 36.6 2,350 2 x 4.0 13.8 240 3 x 4.0 14.8 312 4 x 4.0 15.8 384 5 x 4.0 17.5 478 7 x 4.0 18.8 587 Size 2 Nominal overall diameter Weight kg/ 2 x 6.0 15.4 316 3 x 6.0 16.2 407 4 x 6.0 17.9 508 5 x 6.0 19.4 617 7 x 6.0 21.4 789 2 x 10 18.9 467 3 x 10 20.1 621 4 x 10 21.9 779 5 x 10 24.3 978 7 x 10 26.5 1,250 3 x 16 23.8 857 4 x 16 25.5 1,040 5 x 16 28.6 1,300 3 x 25 25.5 1,110 4 x 25 27.2 1,350 5 x 25 31.3 1,740 5 x 35 36 3,185 4 x 50 3409 2,689 4 x 70 44.8 3,583 4 x 95 47.8 4,935 For current ratings refer to IEE Regulations tables 4F3A and B pages 127 to 128. 28

LiYCY Cable Cable Application PVC insulated and sheathed Controlflex Type CY Screened for use as a signal and data control cable in control circuits, machine tools, computer systems, industrial plants, production lines and electronics. The tinned copper wire screen offers protection from electromagnetic interference (EMI) and reduces electromagnetic radiation (EMR). Technical Information Conductors: Plain annealed flexible copper to IEC 60228, class 5 Insulation: PVC (Polvinyl chloride) colour or number coded cores Screen: Melinex tape & TCWB (Tinned copper wire braid) Sheath: PVC (Polvinyl chloride) Colour: Grey Voltage: 300/500V Operating Temperature: Static: -20 C to 80 C Flexing: -50 C to 70 C Minimum Bending Radius: Flexing: 15 x Ø Static: 6 x Ø Standards: VDE0250: Insulated power cables. General specifications FLEXIBLE CONTROL CABLES Size 2 Nominal overall diameter Weight 2 x 0.5 6.5 59 2 x 0.75 6.8 71 2 x 1.0 7.1 80 2 x 1.5 7.7 97 2 x 2.5 9.3 140 2 x 4 11.5 206 2 x 6 12.9 268 3 x 0.5 6.8 79 3 x 0.75 7.1 85 3 x 1.0 7.4 97 3 x 1.5 8.3 124 3 x 2.5 9.8 177 3 x 4 12.1 264 3 x 6 13.9 357 3 x 10 18.0 500 3 x 16 21.4 800 4 x 0.5 7.4 83 4 x 0.75 7.6 101 4 x 1.0 8.0 117 4 x 1.5 9.2 154 4 x 2.5 10.6 217 4 x 4 14.4 364 4 x 6 15.2 446 4 x 10 20.3 783 4 x 16 23.9 1,250 4 x 25 31.5 2,142 5 x 0.5 7.7 94 Size sq 2 Nominal overall diameter Weight 5 x 0.75 8.2 118 5 x 1.0 9.0 144 5 x 1.5 9.9 181 5 x 2.5 11.7 263 5 x 4 14.6 399 5 x 6 16.7 543 5 x 10 22.2 876 5 x 16 26.1 1,415 5 x 25 31.1 2,047 7 x 0.5 8.5 1,191 7 x 0.75 9.2 154 7 x 1.0 9.6 178 7 x 1.5 10.7 228 7 x 2.5 12.7 337 7 x 4 15.9 516 7 x 6 18.2 709 12 x 0.5 11.3 201 12 x 0.75 12.0 242 12 x 1.0 12.7 284 12 x 1.5 14.1 369 12 x 2.5 16.8 549 18 x 0.5 12.6 248 18 x 0.75 13.6 304 18 x 1.0 14.3 354 18 x 1.5 15.8 453 18 x 2.5 21.1 787 25 x 0.5 14.8 347 LiYCY Cable 29

LiYCY Cable FLEXIBLE CONTROL CABLES Size 2 Nominal overall diameter Weight 25 x 0.75 16.1 436 25 x 1.0 17.2 520 25 x 1.5 19.1 684 25 x 2.5 23.1 1050 34 x 0.5 16.4 410 34 x 0.75 18.2 529 34 x 1.0 19.7 662 34 x 1.5 21.9 850 34 x 2.5 28.2 1,383 Size 2 LSHF versions are available for applications in public buildings. For current ratings refer to IEE Regulations table 4F3A page 127. Nominal overall diameter Weight 50 x 0.5 19.3 609 50 x 0.75 21.5 790 50 x 1.0 23.2 960 50 x 1.5 25.8 1,280 50 x 2.5 31.2 1,970 61 x 0.75 22.2 894 61 x 1.5 27.7 1,520 80 x 0.75 26.6 1,180 80 x 1.5 32.6 2,000 2182Y 2183Y 30

2182Y and 2183Y Flexible Cord for Light Duty Applications Cable Application Harmonised 60 o C flexible PVC cable designed for night duty applications in the office and on small appliances. Annealed copper conductors PVC insulated, two cores twisted together and oversheathed in PVC type TM2 to form a round cable. Harmonised code number H03VV-F2. 300V rated. Radial thickness () CSA ( 2 ) Construction Current rating Insulation Sheath Nominal diameter () 2182Y Weight 0.5 16/0.2 3 Amps 0.5 0.6 5.4 36 0.75 24/0.2 6 Amps 0.5 0.6 5.8 45 Annealed copper conductors PVC insulated, three cores twisted together and oversheathed in PVC type TM2 to form a round cable. Harmonised code number H03VV-F3. FLEXIBLE CONTROL CABLES Radial thickness () CSA ( 2 ) Construction Current rating Insulation Sheath Nominal diameter () 2183Y 3182Y/H05VV-F and 3183Y Cable Flexible Cord for Medium Duty Applications Cable Application Harmonised 60 o C flexible PVC cable designed for medium duty applications in the office and for external connection of portable appliances. Weight 0.5 16/0.2 3 Amps 0.5 0.6 5.6 44 0.75 24/0.2 6 Amps 0.5 0.6 6.1 55 See opposite page for sample images Annealed copper conductors PVC insulated, two cores twisted together and oversheathed in PVC type TM2 to form a round cable. Harmonised code number H05VV-F2. 300-500V rated. Radial thickness () CSA ( 2 ) Construction Current rating Insulation Sheath Nominal diameter () 3182Y/H05VV-F Cable Weight 0.5 16/0.2 3 Amps 0.6 0.8 6.3 40 0.75 24/0.2 6 Amps 0.6 0.8 6.8 63 1.0 32/0.2 10 Amps 0.6 0.8 7.2 73 1.25 40/0.2 13 Amps 0.7 0.8 7.8 84 1.5 30/0.25 15 Amps 0.7 0.8 8.2 95 2.5 50/0.25 20 Amps 0.8 1.0 10.0 154 3182Y/H05VV-F 31

FLEXIBLE CONTROL CABLES 3182Y/H05VV-F and 3183Y Cable Flexible Cord for Medium Duty Applications Annealed copper conductors PVC insulated, three cores twisted together and oversheathed in PVC type TM2 to form a round cable. Harmonised code number H05VV-F3 (1.25 2 National type only). Radial thickness () CSA ( 2 ) Construction Current rating Insulation Sheath Nominal diameter () 3183Y Cable 3192Y and 2192Y Flexible Thin Flat PVC Cable Weight 0.75 24/0.2 6 Amps 0.6 0.8 6.8 74 1.0 32/0.2 10 Amps 0.6 0.8 7.2 86 1.25 40/0.2 13 Amps 0.7 0.9 7.8 104 1.5 30/0.25 15 Amps 0.7 0.9 8.2 120 2.5 50/0.25 20 Amps 0.8 1.1 10.0 180 4.0 56/0.3 25 Amps 0.8 1.2 11.9 180 Cable Application Suitable for domestic use. Annealed copper conductors PVC insulated, two cores twisted together and oversheathed in PVC type flat cable. Harmonised code number H05VVH2-F. 300-500V rated Radial thickness () CSA ( 2 ) Construction Current rating Insulation Sheath Nominal diameter () 3192Y Mains Cable Weight 1.0 32/0.2 10 Amps 0.6 0.8 4.6 x 7.2 51 Annealed copper conductors PVC insulated, two cores laid parallel and oversheathed in PVC type flat cable. Harmonised code number H03VVH2-F2. 300V rated. Radial thickness () CSA ( 2 ) Construction Current rating Insulation Sheath Nominal diameter () 2192Y PVC/PVC 300/300V Weight 0.5 16/0.2 3 Amps 0.5 0.6 5.6 44 0.75 24/0.2 6 Amps 0.5 0.6 6.1 55 For current ratings refer to IEE Regulations tables 4F3A and B pages 127 to 128. 3183Y 32

Arctic Cable Cable Application Arctic grade PVC flexible cords, 300/500V Cable. Primarily designed to stay flexible at extremely low temperatures. Used in the connection of electrical appliances for outdoor industrial installations that need to remain operational in extreme climatic conditions. Generally to BS6500: electric cables, flexible chords rated up to 300/500V for use in domestic offices and similar applications. Technical Information Conductors: Flexible class 5 plain annealed stranded copper to IEC 60228 (formally BS 6360) Insulation: Arctic grade PVC Type TI 4 to BS 7655 Sheath: Arctic Grade PVC Type 8 to BS 7655 Sheath Colour: Available in yellow (for 110V applications) and blue (for 220V applications) Voltage Rating: 300/500V Temperature Range: -40 C to +70 C Cables Types 3182AG: 3183AG: 2 core round profile Colours brown and blue 3 core round profile Colours brown, blue and green/yellow FLEXIBLE CONTROL CABLES Cross sectional area ² Number and Nominal diameter of strands number/ Current rating amps Nominal thickness of insulation Nominal thickness of sheath Nominal overall diameter Nominal weight 1.5 30/0.25 15 0.7 1.1 8.9 120 2.5 50/0.25 20 0.8 1.2 10.8 180 4.0 51/0.30 25 0.8 1.2 11.3 225 6.0 76/0.30 34 0.8 1.4 13.2 315 For current ratings refer to IEE Regulations tables 4F3A and B pages 127 to 128. Arctic Cable 33

Defence Standard Cables DATA / TELEPHONE CABLES Cable Application Popular applications include avionic control systems, computers, data processing and military vehicles, and signalling. Defence standard cable, although originally for defence/military use, is now widely used in industry as it is compact, has a range of sizes for most applications and a high working voltage. As well as PVC, CSE can also supply an LSHF version. The most coon defence standard cable are: 7-2-*A Unscreened black PVC (24AWG) 7/0.20 PVC insulation PVC sheath, black 440V sub-miniature To defence standard 61-12 Pt 4 Operating temperature: 70 o C Available in the following core configurations: 2, 3, 4, 6, 8, 10, 12, 15, 18, 25, 36. Also available with LSHF sheath. 7-2-*C Brain screened black PVC (24AWG) 7/0.2 PVC insulated TCWB screen PVC sheathed 440V sub-miniature To defence standard 61-12 Pt 4. Available in the following core configurations: 2, 3, 4, 6, 8, 10, 12, 15, 18, 25, 36. Also available with LSHF sheath. 7-2-*S Foil screened black PVC (24AWG) 7/0.2 TCW PVC insulated Alu foil screen PVC sheathed 440V sub-miniature. Available in the following core configurations: 2, 3, 4, 6, 8, 10, 12, 15, 18, 25 and 36. 16-2-*A Unscreened black PVC (22AWG) 16/0.2 PVC insulated PVC sheathed 440V cores To defence standard 61-12 Pt 5. Available in the following core configurations: 2, 3, 4, 6, 12, 18 and 25. Also available with LSHF outer sheath. 16-2-*C Braid screened black PVC (22AWG) 16/0.2 PVC insulated TCWB screen PVC sheathed 440V cores To defence standard 61-12 Pt 5. Available in the following core configurations: 2, 3, 4, 6, 10, 12, 15, 25, 36. Also available with LSHF sheath. Defence Standard Cable 34

Colour Chart for Def 61-12 Cables Core Base colour Stripe 1 Red 2 Blue 3 Green 4 Yellow 5 White 6 Black 7 Brown 8 Violet 9 Orange 10 Pink 11 Turquoise 12 Grey 13 Red Blue 14 Green Red 15 Yellow Red 16 White Red 17 Red Black 18 Red Brown Core Base colour Stripe 19 Yellow Blue 20 White Blue 21 Blue Black 22 Orange Blue 23 Green Blue 24 Grey Blue 25 Yellow Green 26 White Green 27 Green Black 28 Orange Green 29 Grey Green 30 Yellow Brown 31 White Brown 32 Brown Black 33 Grey Brown 34 Yellow Violet 35 Violet Black 36 White Violet DATA / TELEPHONE CABLES 35

BS5308 Cable DATA / TELEPHONE CABLES CSE Cables supplies the full range of BS5308 cables including: Part 1 - Type 1 - Unarmoured: collectively screened and Individually & collectively screened Part 1 - Type 2 - Armoured: collectively screened and Individually & collectively screened Cable Application Generally used in indoor applications these cables are designed to connect counication systems and electrical instrumentation in and around process plants in the oil, petro-chemical, gas and other industries. These cables are not for direct connection to the public mains supply. Part 1 - Type 1 - Unarmoured Construction 1. Plain annealed copper wire conductors to IEC 60228/BS 6360. 2. Type 03C polyethylene insulation to BS 6234. 3. Individual pair screen (optional): a) Aluminium/polyester tape, metallic side down, in contact with minimum 0.5 2 tinned copper drain wire. b) Polyester isolating tape(s) numbered for identification. 4. Polyester isolating tape(s). 5. Collective screen (optional) - Aluminium/polyester tape, metallic side down, in contact with minimum 0.5 2 tinned copper drain wire. 6. RP PVC type TM2 to BS 7655, voltage rating: 300/500V. Outer sheath colours available are blue for intrinsically safe circuits and black as standard. Also available is LSHF (Low Smoke Halogen Free) type LTS3 to BS7655. 300/500V rated. BS5308 Cable Part 1 - Type 1 - Unarmoured Construction Part 1 cables are colour coded in accordance with table 1 on page 132. 36

Part 1 - Type 2 - Armoured Construction Cable Application Generally suitable for outdoor applications, specifically direct buriel within the petro-chemical industries. 1. Plain annealed copper wire conductors to IEC 60228/BS 6360. 2. Type 03C polyethene insulation to BS 6234. 3. Individual pair screen (optional): a) Aluminium/polyester tape, metallic side down, in contact with minimum 0.5 2 tinned copper drain wire. b) Polyester isolating tape(s) numbered for identification. 4. Polyester binder tape. DATA / TELEPHONE CABLES 5. Collective screen (optional) - Aluminium/polyester tape, metallic side down, in contact with minimum 0.5 2 tinned copper drain wire. 6. Type 03C black polyethylene bedding to BS 6234. 7. Single layer galvanised steel wire armour to BS EN 10257-1. 8. RP PVC type TM2 to BS 7655, voltage rating: 300/500V. Outer sheath colours available are blue for intrinsically safe circuits and black as standard. Also available is LSHF (Low Smoke Halogen Free) type LTS3 to BS7655. 300/500V rated. Part 1 cables are colour coded in accordance with table 1 on page 132. BS5308 Cable Part 1 - Type 1 - Unarmoured Construction 37

BS5308 Cable DATA / TELEPHONE CABLES Part 2 - Type 1 - Unarmoured Construction 1. Plain annealed copper wire conductors to IEC 60228/BS 6360. 2. Type TI1 PVC to BS EN 50363. 3. Individual pair screen (optional): a) Aluminium/polyester tape, metallic side down, in contact with minimum 0.5 2 tinned copper drain wire b) Polyester isolating tape(s) numbered for identification 4. Polyester binder tape. 5. Collective screen (optional) - Aluminium/polyester tape, metallic side down, in contact with minimum 0.5 2 tinned copper drain wire. 6. RP PVC type TM2 to BS 7655, voltage rating: 300/500V. Outer sheath colour available are blue for intrinsically safe circuits and black as standard. Also available in LSHF (Low Smoke Halogen Free) type LTS3 to BS 7655. 300/500V rated. Part 2 cables are colour coded in accordance with table 2 on page 133. 38

Part 2 - Type 2 - Armoured Construction 1. Plain annealed copper wire conductors toec 60228/BS 6360. 2. Type TI1 PVC to BS EN 50363. 3. Individual pair screen (optional):- a) Aluminium/polyester tape, metallic side down, in contact with minimum 0.52 tinned copper drain wire b) Polyester isolating tape(s) numbered for identification 4. Polyester binder tape. 5. Collective screen (optional) - Aluminium/polyester tape, metallic side down, in contact with minimum 0.5 2 tinned copper drain wire DATA / TELEPHONE CABLES 6. Type TI1 PVC to BS EN 50363. 7. Single layer galvanised steel wire armour to BS EN 10257-1. 8. RP PVC type TM2 to BS 7655, voltage rating: 300/500V. Outer sheath colours available are blue for intrinsically safe circuits and black as standard. Also available in LSHF (Low Smoke Halogen Free) type LTS3 to BS 7655. 300/500V rated. Part 2 cables are colour coded in accordance with table 2 on page 133. 39

Data Cables DATA / TELEPHONE CABLES Below are just a very small selection of the data cable available, if you cannot find the cable for your application do not hesitate to call one of our dedicated sales lines who will be more than willing to help. Low Smoke Halogen Free (LSHF), SWA, duct grade data cable also available on request. Single Pair Foil Screened Cable Application General purpose foil screened single pair cables, frequently used in audio, data, and instrumentation applications. These cables have a polyethylene insulation which results in lower signal loss than standard PVC insulation. Part number AWG Number of pairs O/D Belden alternate to Pair colours DAT 8761 22 1 4.6 8761 Black/clear DAT 8762 20 1 5.1 8762 Black/clear DAT 8760 18 1 6.0 8760 Black/clear DAT 8719 16 1 7.9 8719 Black/clear DAT 8720 14 1 9.0 8720 Black/clear DAT 8451 22 1 3.4 8451 Black/red Two Pair Individually Foil Screened 22AWG Cable Application Used extensively in the security industry for CCTV applications including telemetry. Also suitable for computer and instrumentation applications where it is important to provide a high level screening from external sources, together with a low level of cross talk between pairs. These cables have conductors of 24 AWG tinned copper wire PVC insulation and are laid up in twisted pairs with an overall Beldfoil aluminium-polyester shield providing screening sheathed in chrome pvc grey with a 24 AWG tinned copper drain wire. Part number AWG Number of pairs O/D Belden number DAT 8723 22 2 4.2 8723 Pair Colours Red & black Green & white DAT 8723 DAT 8761 40

Overall Foil Screened Multi Pairs 24AWG Cable Application Widely used for computers, point of sale, control systems, and RS232 applications. This is a general purpose twisted pair cable with overall screen. Part number AWG Number of pairs O/D Belden number Weight DAT 9501 24 1 3.9 9501 19.3 DAT 9502 24 2 5.6 9502 31.4 DAT 9503 24 3 5.9 9503 39.9 DAT 9504 24 4 6.7 9504 48.9 DAT 9505 24 5 7.4 9505 56.9 DAT 9506 24 6 7.8 9506 69.00 DAT 9507 24 7 8.4 9507 72.2 DAT 9508 24 8 8.3 9508 78.8 DAT 9509 24 9 8.9 9509 92.8 DAT 9510 24 10 9.4 9510 98.0 DAT 9515 24 15 10.8 9515 135.0 DAT 9519 24 19 11.5 9519 164.6 DAT 9525 24 25 13 9525 215 DATA / TELEPHONE CABLES Pair Colours 1 Pair: Black & red 2 Pairs: Black & white 3 Pairs: Black & green 4 Pairs: Black & blue 5 Pairs: Black & yellow 6 Pairs: Black & brown 7 Pairs: Black & orange 8 Pairs: Red & white 9 Pairs: Red & green 10 Pairs: Red & blue 11 Pairs: Red & yellow 12 Pairs: Red & brown 13 Pairs: Red & orange 14 Pairs: Green & white 15 Pairs: Green & blue 16 Pairs: Green & yellow 17 Pairs: Green & brown 18 Pairs: Green & orange 19 Pairs: White & blue 20 Pairs: White & yellow 21 Pairs: White & brown 22 Pairs: White & orange 23 Pairs: Blue & yellow 24 Pairs: Blue & brown 25 Pairs: Blue & orange DAT 9503 41

Data Cables DATA / TELEPHONE CABLES Individually Foil Screened Multi Pairs 22 AWG Cable Application Designed primarily for use in radio frequency applications requiring superior circuit isolation, also suited to computer and data transmission applications. The cables have conductors of 22 AWG tinned copper wire, polypropylene insulated, twisted pins, each pair having an individual Beldfoil aluminium-polyester foil screen. Overall sheath of chrome grey pvc and a 22 AWG tinned copper drain. LSHF versions are also available. 300V rated. Part number AWG Number of pairs O/D Belden number Weight DAT 8777 22 3 7.3 8777 68 DAT 8778 22 6 9.8 8778 127 DAT 8774 22 9 11.4 8774 152.7 DAT 8775 22 11 12.0 8775 194 DAT 8768 22 12 12.5 9768 210 DAT 8776 22 15 314 8776 271.2 DAT 9769 22 17 14.7 9769 309.7 DAT 8769 22 19 15.3 8769 334.4 DAT 8773 22 27 18.5 8773 452.6 DAT 9767 22 37 20.5 9767 621.4 Individually Foil Screened Multi Pairs 22 AWG Pair Colours 1 Pair: Black & red 2 Pairs: Black & white 3 Pairs: Black & green 4 Pairs: Black & blue 5 Pairs: Black & yellow 6 Pairs: Black & brown 7 Pairs: Black & orange 8 Pairs: Red & white 9 Pairs: Red & green 10 Pairs: Red & blue 11 Pairs: Red & yellow 12 Pairs: Red & brown 13 Pairs: Red & orange 14 Pairs: Green & white 15 Pairs: Green & blue 16 Pairs: Green & yellow 17 Pairs: Green & brown 18 Pairs: Green & orange 19 Pairs: White & blue 20 Pairs: White & yellow 21 Pairs: White & Brown 22 Pairs: White & orange 23 Pairs: Blue & yellow 24 Pairs: Blue & brown 25 Pairs: Blue & orange 26 Pairs: Brown & yellow 27 Pairs: Brown & orange 28 Pairs: Orange & yellow 29 Pairs: Purple & orange 30 Pairs: Purple & red 31 Pairs: Purple & white 32 Pairs: Purple & green 33 Pairs: Purple & blue 34 Pairs: Purple & yellow 35 Pairs: Purple & brown 36 Pairs: Purple & black 37 Pairs: Grey & white 42

Single Pair Unscreened Cable Application General purpose single pair unscreened data cables for use in instrumentation, data, security, bus and audio applications where protection against electrical interference is not required. LSHF versions are also available. Part number AWG Number of pairs O/D Belden number Pair colours Weight DAT 8442 22 1 4.32 8442 black/red 23 DAT 8205 20 1 4.57 8205 black/red 26 DAT 9740 18 1 6.0 9740 black/red 37 DAT 8471 16 1 6.96 8471 black/white 56 DAT 8473 14 1 8.5 8473 black/white 89 Foil and Braid Shielded Pairs DATA / TELEPHONE CABLES Cable Construction 24 AWG (7/0.2) TCW conductor, PE insulated, twisted pairs, overall aluminium/polyester foil shield with 24 AWG (7/0.2) TCW drain wire, overall TCW braid screen (90% coverage), grey PVC sheath. Grey LSHF sheath is also available and black UV resistant PE sheath is available too. Equivalents Pairs CSE reference Belden Diameter Weight 1 DAT 9841 9841 5.90 64 1 DAT 9841-LSHF - 5.90 64 2 DAT 9842 9842 8.60 95 2 DAT 9842-LSHF - 8.60 95 2 DAT 9842-PE - 8.60 118 3 DAT 9843 9843 9.20 108 4 DAT 9844 9844 9.90 125 4 DAT 9844-LSHF - 9.90 125 Electrical Characteristics Conductor DC Resistance: 86.2 [Ω\km] Rated Temperature: 80 o C [PE 70 o C] Rated Voltage: 300V Insulation Resistance: 200 [MΩ/km] Nominal Capacitance: 42 pf/m Velocity Ratio: 66% Nimonal Impedance: 120[Ω/km] Colour Code 1 Pair: Blue/white 2 Pairs: Orange/white 3 Pairs: White/green 4 Pairs: White/brown DAT 9841 DAT 8471 43

Cat 5E and CAT6 Cable DATA / TELEPHONE CABLES Cable Application There are a range of high quality Cat 5E cables available from CSE Cables. Used mainly for data transmission, these cables offer extended transmission distances over frequency ranges up to 350Mhz and data speeds up to 1000Mbps. LSHF, duct grade and SWA versions are also available from stock. Cat 5E UTP PVC Technical Information Conductor: Insulation: Drain Wire: Sheath: Colour: Temperature Rating: Class 1 solid plain copper (flexible stranded copper conductor available upon request) PE (polythelene) Tinned copper PVC (LSHF available upon request) Grey (other colours available on request) 70 o C (Screened version FTP available upon request) We also stock 25 x 2 x 24 AWG and 50 x 2 x 24 AWG in both PVC and LSHF. Cat 6 UTP PVC Technical Information Conductor: Insulation: Drain Wire: Sheath: Colour: Temperature Rating: Class 1 solid plain copper PE (polythelene) Tinned copper PVC (LSHF available upon request) Grey (other colours available) 70 o C (Screened version FTP available) Cat 5E Cable 44

CW 1308 Internal Telephone Cable Cable Application A range of cables primarily designed for the interconnection of telephone equipment which is installed indoors. These cables may also be used for interconnection of other counication and control equipment or low level signalling applications. Standards: CW 1308 is available from 1 pair to 320 pairs. CW1308 is also available in LSHF. Technical Information Conductor: Insulation: Pairs: Core: Screening: Outer sheath: Maximum Conductor Resistance at 20 o C: Minimum Insulation Resistance at 20 o C: Maximum Capacitance Unbalance: Minimum Bending Radius: Temperature Range during Operation: Temperature Range during Installation: Tinned/plain copper, 1/0.5 PVC, insulated conductors twisted into pairs Laid up in concentric layers Covered with PET foil Aluminium/PET screen with drain wire PVC with ripcord, white or black 97.8 Ohm/km 50 Mohmxkm 500 pf/500m 15 x Ø -30 o C to +70 o C -5 o C to +50 o C DATA / TELEPHONE CABLES Number of pairs Conductor diameter O/D Weight 2 1/0.50 4.5 22 3 1/0.50 5 31 4 1/0.50 5.8 34 5 1/0.5 6.3 39 6 1/0.50 6.8 50 8 + E 1/0.50 7.6 58 10 + E 1/0.50 8.6 102 20 + E 1/0.50 12 161 25 + E 1/0.50 12.9 172 50 + E 1/0.50 17 352 100 + E 1/0.50 27 687 200 + E 1/0.50 32 1,298 CW 1308 Internal Telephone Cable 45

CW 1128 Telephone Cable DATA / TELEPHONE CABLES CW1128 External Cable Solid plain annealed copper conductors, Cel-PE (cellular polyethelene) insulated, PJF-petroleum jelly filled, polyethylene sheath. Black. Technical Information Sheath Colour: Minimum Bending Radius: Black 10 x Ø Maximum Conductor Resistance at 20 o C: 91/ohm/km Minimum Insulation Resistance at 20 o C megaohms/km: 1500 Average Mutual Capacitance nanofarads/km: 56 (n/a to screened versions) Diameter of Conductor - : 0.5 Size of Conductor - 2 : 0.2 Radial Thickness of Insulation - : 0.2 Nominal Diameter of Core - : 0.9 Operating Temperature: Maximum: 40 o C* Minimum Bending: 0 o C *Max continuous temperature of standard jelly compound Number of pairs Conductor diameter O/D Weight 2 0.5 6.8 5 0.5 6.8 10 0.5 8.3 20 0.5 12.5 50 0.5 15.5 100 0.5 20.3 CW1128/1198 Telephone Cable Cable Application For Interconnecting telephone equipment externally. CW1128/1198 external armoured cable may be used. It is UV and moisture resistant and can also be used for direct burial. Available from 5 pairs to 100 pairs. Also available with 0.9 conductors. Solid plain annealed copper conductors 1/0.9, cellular polyethelene insulated, PJF - petroleum jelly filled, collective aluminium/mylar tape screen, polyethelene bedding, galvanized steel wire armour, pvc outer sheath. Black to BS3573 and CW1128/1198. Flame Propogation to BS4066 PTI and IEC 332PTI. CW 1128 Telephone Cable Number of pairs Conductor diameter O/D Weight 5 0.63 16.7 10 0.63 19.9 20 0.63 24.8 50 0.63 34.5 46

CSE BMS 600V Rated Cable Twisted pair cables are available as screened and unscreened and can be used for popular Building Management Systems Applications. Screened cables have twisted pairs wrapped in an aluminium polyester tape with a tinned copper drain wire. These cables feature a flame retardant halogen free sheath and have a 600V rating. The cable is stocked in 500m reels and can be cut to order. We stock other types of 600V rated Belden equivalent cables. TP/1/22/HF600 TP/2/22/HF600 Belden Equivalent 8761NH 8723NH Cable Construction Stranded Tinned Copper: 1 Pair 2 Pairs AWG: 22 22 Construction: T0.25 ± 0.005 x 7 T0.25 ± 0.008 x 7 Stranded Dia. (±0.05): 0.77 0.76 Insulation: HDPE HDPE Thickness: 0.41 0.2 Insulation Dia.(±0.1): 1.60 1.20 Insulation Colour: Natural/black Red/black; green/white Shield: AL/PET AL/PET Construction: Each pair is twisted Each pair is twisted with 1 AL-PET 100% individual aluminium foil screening Polyester Tape Screen Drain Wire: Stranded Tinned Copper Stranded Tinned Copper AWG: 22 24 Construction: T0.25 ± 0.005 x 7 T0.20 ± 0.008 x 7 Jacket: LSHF LSHF Thickness (): 0.6 0.45 Diam. (±0.15): 4.50 4.20 Jacket Colour: Grey Grey Ordering: 500M wooden drum 500M wooden drum or cut to length or cut to length DATA / TELEPHONE CABLES Electrical Characteristics Maximum Conductor DC Resistance at 20 o C (Ω/Km): <54.2 <55.2 Rated Temperature: 70 o C 70 o C Operating Voltage: 600V 600V 20 o C Insulation Resistance (M Ω. KM): >200 >200 Nominal Capacitance (PF/M; 10%): 80 115 Nominal Velocity ratio: 66% 66% Nominal Impedance (Ω): 64 45 CSE BMS 600V Rated Cable 47

Multicore Voltage Power Cable POWER CABLES BS5467 Cu/XLPE/PVC/SWA/PVC 0.6/1kV Cable Application Cu/XLPE/PVC/SWA/PVC power cable may be used for fixed installation indoors and outdoors in cable ducts or directly in the ground. The steel wire armoured cable is the accepted standard for underground installations, designed for use in mains supply electricity. These cables are provided with mechanical protection and are therefore suitable for external use, direct burial and areas where sudden mechanical stress are expected. Technical Information Conductor Material: Conductor Shape: Copper, IEC60228 1.5² up to 16² Circular 25² up to 400² Sector-shaped Conductor Flexibility: Stranded class 2 Insulation: XLPE (Cross-linked Polyethylene), IEC60502 Armour Type: Galvanized steel wires Outer Sheath: PVC, IEC60502 Inner Sheath: PVC, IEC60502 Colour: Black Lead Free: Yes Rated Voltage Uo/U (Um): 600/1000V, BS5467 Installation Temperature: Minimum: 0 C Maximum: 60 C Installation Type: Outdoor Direct burial Operating Temperature: Maximum: 90 C Short-circuit Maximum Conductor Temperature: 250 C Flame Retardant: IEC 60332-1 Bending Radius: 1.5² up to 16² = 6 x Ø 25² up to 400² = 8 x Ø Part number Cross section 2 Stranding Approx weight Approx overall diameter Gland size Single cleat Nom. Max. DC-resist conductor 20 o C ohm/km Current rating laid direct amp 2 Core: Brown & Blue SWAPVC2X1.5 2 x 1.5 7/0.53 243 11.06 16 0.5 12.10 38 SWAPVC2X2.5 2 x 2.5 7/0.67 355 12.4 20s 0.5 7.41 49 SWAPVC2X4.0 2 x 4.0 7/0.85 393 13.38 20s 0.6 4.61 65 Multicore Voltage Power Cable SWAPVC2X6.0 2 x 6.0 7/1.04 450 14.38 20 0.6 3.08 81 SWAPVC2X10 2 x 10 7/1.35 590 16.18 20 0.7 1.83 109 SWAPVC2X16 2 x 16 7/1.70 897 19.06 25 0.8 1.15 141 2 Core: Brown & Blue SWAPVC2X25 2 x 25 7/2.14 1,050 20.0 25 0.8 0.727 183 SWAPVC2X35 2 x 35 7/2.52 1,400 23.2 32 0.9 0.524 219 SWAPVC2X50 2 x 50 19/1.78 1,750 25.1 32 1.0 0.387 259 48

Part number 2 Core: Brown & Blue Cross section 2 Stranding Approx weight Approx overall diameter Gland size Single cleat Nom. Max. DC-resist conductor 20 o C ohm/km Current rating laid direct amp SWAPVC2X70 2 x 70 19/2.14 2,200 28.5 32 1.2 0.268 317 SWAPVC2X95 2 x 95 19/2.52 3,100 32.9 32 1.4 0.193 381 SWAPVC2X120 2 x 120 37/2.03 3,700 35.1 40 1.4 0.153 433 SWAPVC2X150 2 x 150 37/2.25 4,350 37.8 40 1.6 0.124 485 SWAPVC2X185 2 x 185 37/2.52 5,700 44.7 50s 1.8 0.0991 547 SWAPVC2X240 2 x 240 61/2.25 7,280 49.0 50 2.0 0.0754 632 SWAPVC2X300 2 x 300 61/2.52 8,750 53.4 63s 2.0 0.0601 708 SWAPVC2X400 2 x 400 61/2.85 10,700 59.0 63s TC9 0.0470-3 Core: Brown, Black & Grey SWAPVC3X1.5 3 x 1.5 7/0.53 341 12.17 16 0.5 12.10 32 SWAPVC3X2.5 3 x 2.5 7/0.67 374 13.55 20s 0.6 7.41 42 SWAPVC3X4.0 3 x 4.0 7/0.85 458 14.68 20s 0.6 4.61 55 SWAPVC3X6.0 3 x 6.0 7/1.04 558 15.87 20 0.7 3.08 69 SWAPVC3X10 3 x 10 7/1.35 841 18.63 20 0.8 1.83 92 SWAPVC3X16 3 x 16 7/1.70 1,070 20.78 25 0.9 1.15 119 SWAPVC3X25 3 x 25 7/2.14 1,625 24.9 32 1.0 0.727 152 SWAPVC3X35 3 x 35 7/2.52 1,950 27.8 32 1.1 0.524 182 SWAPVC3X50 3 x 50 19/1.78 2,300 28.0 32 1.2 0.387 217 SWAPVC3X70 3 x 70 19/2.14 3,075 32.2 32 1.4 0.268 266 SWAPVC3X95 3 x 95 19/2.52 4,225 37.0 40 1.6 0.193 319 SWAPVC3X120 3 x 120 37/2.03 5,100 40.2 50s 1.8 0.153 363 SWAPVC3X150 3 x 150 37/2.25 6,510 45.3 50s 1.8 0.124 406 SWAPVC3X185 3 x 185 37/2.52 7,845 49.5 50 2.0 0.0991 458 SWAPVC3X240 3 x 240 61/2.25 9,900 55.6 63s TC9 0.0754 529 SWAPVC3X300 3 x 300 61/2.52 13,560 59.6 63 TC10 0.0601 592 SWAPVC3X400 3 x 400 61/2.85 14,720 65.8 75s TC11 0.0470 667 4 Core: Brown, Black, Grey & Blue SWAPVC4X1.5 4 x 1.5 7/0.53 351 12.88 20s 0.5 12.10 32 SWAPVC4X2.5 4 x 2.5 7/0.67 429 14.43 20s 0.6 7.41 42 SWAPVC4X4.0 4 x 4.0 7/0.85 538 16.87 20 0.6 4.61 55 SWAPVC4X6.0 4 x 6.0 7/1.04 670 17.87 20 0.7 3.08 69 SWAPVC4X10 4 x 10 7/1.35 998 20.1 25 0.8 1.83 92 SWAPVC4X16 4 x 16 7/1.70 1,272 22.4 25 0.9 1.15 119 SWAPVC4X25 4 x 25 7/2.14 1,940 27.0 32 1.0 0.727 152 SWAPVC4X35 4 x 35 7/2.52 2,390 30.1 32 1.2 0.524 182 4 Core: Brown, Black, Grey & Blue SWAPVC4X50 4 x 50 19/1.78 2,925 31.5 32 1.4 0.387 217 POWER CABLES 49

Multicore Voltage Power Cable POWER CABLES Part number Cross section 2 4 Core: Brown, Black, Grey & Blue Stranding Approx weight Approx overall diameter Gland size Single cleat Nom. Max. DC-resist conductor 20 o C ohm/km Current rating laid direct amp SWAPVC4X70 4 x 70 19/2.14 4,200 37.4 40 1.6 0.268 266 SWAPVC4X95 4 x 95 19/2.52 5,355 40.9 50s 1.8 0.193 319 SWAPVC4X120 4 x 120 37/2.03 6,925 46.6 50 2.0 0.153 363 SWAPVC4X150 4 x 150 37/2.25 8,200 50.2 50s 2.0 0.124 406 SWAPVC4X185 4 x 185 37/2.52 9,975 55.8 63s TC9 0.0991 458 SWAPVC4X240 4 x 240 61/2.52 12,700 62.5 63 TC10 0.0754 529 SWAPVC4X300 4 x 300 61/2.85 15,275 67.4 75s TC11 0.0601 592 SWAPVC4X400 4 x 400 61/3.20 19,875 77.0 75 TC12 0.0470 667 5 Core: White Numbered Cores with Black Print SWAPVC5X1.5 5 x 1.5 7/0.53 395 13.72 20s 0.6 12.10 32 SWAPVC5X2.5 5 x 2.5 7/0.67 497 15.46 20s 0.6 7.41 42 SWAPVC5X4.0 5 x 4.0 7/0.85 674 17.38 20 0.7 4.61 55 SWAPVC5X6.0 5 x 6.0 7/1.04 868 19.05 20 0.8 3.08 69 SWAPVC5X10 5 x 10 7/1.35 1,197 22.06 25 0.9 1.83 92 SWAPVC5X16 5 x 16 7/1.70 1,780 24.14 25 1.1 1.15 119 SWAPVC5X25 5 x 25 7/2.14 2,435 28.4 32 1.2 0.727 152 SWAPVC5X35 5 x 35 7/2.52 2,800 33 40 1.4 0.524 182 SWAPVC5X50 5 x 50 19/1.78 3,850 38.0 40 1.6 0.387 217 SWAPVC5X70 5 x 70 19/2.14 5,100 42.9 50s 1.8 0.268 266 SWAPVC5X95 5 x 95 19/2.52 7,700 52.1 50 TC9 0.193 319 7 Core: White Numbered Cores with Black Print SWAPVC7X1.5 7 x 1.5 7/0.53 449 14.65 20 0.6 12.10 32 SWAPVC7X2.5 7 x 2.5 7/0.67 564 16.53 20 0.8 7.41 42 SWAPVC7X4.0 7 x 4.0 7/0.85 824 18.96 25 0.8 4.61 55 SWAPVC7X6.0 7 x 6.0 7/1.04 1,105 21.6 25 0.9 3.08 69 SWAPVC7X10 7 x 10 7/1.35 1,610 25.3 25 1 1.83 98 SWAPVC7X16 7 x 16 7/1.70 2,225 28.45 32 1.2 1.15 119 SWAPVC7X25 7 x 25 7/2.14 3,880 38.4 40 1.4 0.727 152 12 Core: White Numbered Cores with Black Print SWAPVC12X1.5 12 x 1.5 7/0.53 756 18.9 25 0.8 12.10 32 SWAPVC12X2.5 12 x 2.5 7/0.67 971 21.76 25 0.9 7.41 42 SWAPVC12X4.0 12 x 4.0 7/0.85 1,403 25.97 32 1.0 4.61 55 SWAPVC12X6.0 12 x 6.0 7/1.04 1,910 28.1 32 1.2 3.08 69 SWAPVC12X10 12 x 10 7/1.35 2,590 32.4 32 1.4 1.83 98 19 Core: White Numbered Cores with Black Print SWAPVC19X1.5 19 x 1.5 7/0.53 992 21.99 25 0.9 12.10 32 SWAPVC19X2.5 19 x 2.5 7/0.67 1,447 25.63 25 1.0 7.41 42 50

Part number Cross section 2 Stranding Approx weight 19 Core: White Numbered Cores with Black Print Approx overall diameter Gland size Single cleat Nom. Max. DC-resist conductor 20 o C ohm/km Current rating laid direct amp SWAPVC19X4.0 19 x 4.0 7/0.85 1,870 28.46 32 1.1 4.61 55 27 Core: White Numbered Cores with Black Print SWAPVC27X1.5 27 x 1.5 7/0.53 1,470 21.99 25 1 12.10 32 SWAPVC27X2.5 27 x 2.5 7/0.67 1,905 30.1 32 1.2 7.41 42 SWAPVC27X4.0 27 x 4.0 7/0.85 2,495 33.2 32 1.4 4.61 55 37 Core: White Numbered Cores with Black Print POWER CABLES SWAPVC37X1.5 37 x 1.5 7/0.53 1,640 21.99 32 1.1 12.10 32 SWAPVC37X2.5 37 x 2.5 7/0.67 2,363 30.1 40 1.4 7.41 42 SWAPVC37X4.0 37 x 4.0 7/0.85 3,090 33.2 40 1.4 4.61 55 48 Core: White Numbered Cores with Black Print SWAPVC48X1.5 48 x 1.5 7/0.53 2,145 30.0 40 1.2 12.10 32 SWAPVC48X2.5 48 x 2.5 7/0.67 3,115 37.4 40 1.6 7.41 42 SWAPVC48X4.0 48 x 4.0 7/0.85 4,110 44.5 50s 1.8 4.61 55 Suitable gland types: BW: Internal use only CW: Internal & External E1W: External double compression E1WF: Flameproof For current ratings refer to IEE Regulations tables 4E4A and B pages 120 to 121. 51

Single Core Low Voltage Power Cable POWER CABLES BS5467 Cu/XLPE/PVC/AWA/PVC 0.6/1kV Cable Application Cu/XLPE/PVC/AWA/PVC power cable may be used for fixed installation indoors and outdoors in cable ducts or directly in the ground. Technical Information Conductor Material: Copper, IEC60228 Conductor Shape: 50² up to 400² Circular Conductor Flexibility: Stranded class 2 Outer Sheath: PVC, IEC60502 Inner Sheath: PVC, IEC60502 Insulation: XLPE (Cross-linked Polyethylene), IEC60502 Armour Type: Aluminium wires Colour: Black Lead Free: Yes Rated Voltage Uo/U (Um): 600/1000V, BS5467 Installation Temperature: Minimum: 0 C Maximum: 60 C Installation Type: Outdoor Direct burial Operating Temperature: Minimum: -15 C Maximum: 90 C Short-circuit Maximum Conductor Temperature: 250 C Flame Retardant: IEC 60332-1 and BS EN 50265-2-1 Bending Radius: 50² up to 1000² = 6 x Ø Part number Cross section 2 Stranding Approx weight Approx overall diameter Gland size Single cleat Nom. Max. DC-resist conductor 20 o C ohm/km Current rating laid direct amp Single Core: Brown Inner & Black Outer AWAPVC1X50 1 x 50 19/1.78 669 17.85 20 0.7 0.387 231 AWAPVC1X70 1 x70 19/2.14 946 19.8 25 0.8 0.268 284 AWAPVC1X95 1 x 95 19/2.52 1,233 21.75 25 0.9 0.193 340 AWAPVC1X120 1 x 120 37/2.03 1,481 23.6 25 1.0 0.153 386 AWAPVC1X150 1 x 150 37/2.25 1,875 26.5 32 1.1 0.124 431 AWAPVC1X185 1 x 185 37/2.52 2,275 28.5 32 1.2 0.0991 485 Single Core Low Voltage Power Cable AWAPVC1X240 1 x 240 61/2.25 2,900 32.0 40 1.4 0.0754 558 AWAPVC1X300 1 x 300 61/2.52 3,525 33.5 40 1.4 0.0601 623 AWAPVC1X400 1 x 400 61/2.85 4,575 38.5 40 1.6 0.0470 691 AWAPVC1X500 1 x 500 61/3.2 5,675 43.1 50s 1.8 0.0366 765 AWAPVC1X630 1 x 630 127/2.52 7,175 47.0 50 2.0 0.0283 840 AWAPVC1X800 1 x 800 127/2.85 9,300 54.0 63s TC9 0.0221 888 AWAPVC1X1000 1 x 1000 127/3.2 11,435 58.4 63s TC10 0.0176 942 Suitable gland types: CW Aluminium: Internal & External A2: Compression gland Also available in a low smoke halogen free version. 52

Low Voltage Power Cable BS6724 Cu/XLPE/LSHF/SWA/LSHF 0.6/1kV Cable Application Designed for use in mains supply electricity. These cables are provided with mechanical protection and manufactured using low smoke halogen free compounds. This makes them ideal for use in public buildings and areas where fire and smoke emission create a potential threat to equipment and life. The cable meets the requirements for flaability stated in IEC60332-3 Cat. C and EN 50266-2-4 and has low emission of smoke when burning. The cable is manufactured and tested according to BS 6724. Technical Information Conductor Material: Conductor Shape: Copper, IEC60228 1.5² up to 16² Circular 25² up to 400² Sector-shaped Conductor Flexibility: Stranded class 2 Insulation: XLPE (Cross-linked Polyethylene), IEC60502 Armour Type: Galvanized steel wires Outer Sheath: LSHF, IEC60502 Inner Sheath: LSHF, IEC60502 Colour: Black Lead Free: Yes Rated Voltage Uo/U (Um): 600/1000V, B6724 Installation Temperature: Minimum: 0 C Maximum: 40 C Installation Type: Fixed Indoors and outdoor Direct burial Operating Temperature: Maximum: 90 C Short-circuit Maximum Conductor Temperature: 250 C Flame Retardant: IEC 60332-3 Cat. C Bending Radius: 1.5² up to 16² = 6 x Ø 25² up to 400² = 8 x Ø POWER CABLES Part number Cross section 2 Stranding Approx weight Approx overall diameter Gland size Single cleat Nom. Max. DC-resist conductor 20 o C ohm/km Current rating laid direct amp 2 Core: Brown & Blue SWALSHF2X1.5 2 x 1.5 7/0.53 300 12.3 16 0.5 12.10 38 SWALSHF2X2.5 2 x 2.5 7/0.67 370 12.9 20s 0.5 7.41 49 SWALSHF2X4.0 2 x 4.0 7/0.85 460 13.9 20s 0.6 4.61 65 SWALSHF2X6.0 2 x 6.0 7/1.04 550 15.0 20 0.6 3.08 81 SWALSHF2X10 2 x 10 7/1.35 870 17.05 20 0.7 1.83 109 SWALSHF2X16 2 x 16 7/1.70 1,100 19.5 25 0.8 1.15 141 SWALSHF2X25 2 x 25 7/2.14 1,070 22.1 25 0.8 0.727 183 SWALSHF2X35 2 x 35 7/2.52 1,440 24.95 32 0.9 0.524 219 SWALSHF2X50 2 x 50 19/1.78 1,775 25.4 32 1.0 0.387 259 SWALSHF2X70 2 x 70 19/2.14 2,250 28.5 32 1.2 0.268 317 SWALSHF2X95 2 x 95 19/2.52 3,190 32.55 32 1.4 0.193 381 Multi Core Low Voltage Power Cable 53

Low Voltage Power Cable POWER CABLES Part number 2 Core: Brown & Blue Cross section 2 Stranding Approx weight Approx overall diameter Gland size Single cleat Nom. Max. DC-resist conductor 20 o C ohm/km Current rating laid direct amp SWALSHF2X120 2 x 120 37/2.03 3,700 35.6 40 1.4 0.153 433 SWALSHF2X150 2 x 150 37/2.25 4,375 38.15 40 1.6 0.124 485 SWALSHF2X185 2 x 185 37/2.52 5,650 43.85 50s 1.8 0.0991 547 SWALSHF2X240 2 x 240 61/2.52 7,090 48.5 50 2.0 0.0754 632 SWALSHF2X300 2 x 300 61/2.85 8,475 51.75 63s 2.0 0.0601 708 SWALSHF2X400 2 x 400 61/3.20 10,700 59.0 63 TC9 0.0470 1 3 Core: Brown, Black & Grey SWALSHF3X1.5 3 x 1.5 7/0.53 341 12.17 16 0.5 12.10 32 SWALSHF3X2.5 3 x 2.5 7/0.67 374 13.55 20s 0.6 7.41 42 SWALSHF3X4.0 3 x 4.0 7/0.85 458 14.68 20s 0.6 4.61 55 SWALSHF3X6.0 3 x 6.0 7/1.04 558 15.87 20 0.7 3.08 69 SWALSHF3X10 3 x 10 7/1.35 841 18.63 20 0.8 1.83 92 SWALSHF3X16 3 x 16 7/1.70 1,070 20.78 25 0.9 1.15 119 SWALSHF3X25 3 x 25 7/2.14 1,625 24.9 32 1.0 0.727 152 SWALSHF3X35 3 x 35 7/2.52 1,950 27.8 32 1.1 0.524 182 SWALSHF3X50 3 x 50 19/1.78 2,300 28.0 32 1.2 0.387 217 SWALSHF3X70 3 x 70 19/2.14 3,075 32.2 32 1.4 0.268 266 SWALSHF3X95 3 x 95 19/2.52 4,225 37.0 40 1.6 0.193 319 SWALSHF3X120 3 x 120 37/2.03 5,100 40.2 50s 1.8 0.153 363 SWALSHF3X150 3 x 150 37/2.25 6,510 45.3 50s 1.8 0.124 406 SWALSHF3X185 3 x 185 37/2.52 7,845 49.5 50 2.0 0.0991 458 SWALSHF3X240 3 x 240 61/2.52 9,900 55.6 63s TC9 0.0754 529 SWALSHF3X300 3 x 300 61/2.85 13,560 59.6 63 TC10 0.0601 592 SWALSHF3X400 3 x 400 61/3.20 14,720 65.8 75s TC11 0.0470 667 4 Core: Brown, Black, Grey & Blue SWALSHF4X1.5 4 x 1.5 7/0.53 351 12.88 20s 0.5 12.10 32 SWALSHF4X2.5 4 x 2.5 7/0.67 429 14.43 20s 0.6 7.41 42 SWALSHF4X4.0 4 x 4.0 7/0.85 538 16.87 20 0.6 4.61 55 SWALSHF4X6.0 4 x 6.0 7/1.04 670 17.87 20 0.7 3.08 69 SWALSHF4X10 4 x 10 7/1.35 998 20.1 25 0.8 1.83 92 SWALSHF4X16 4 x 16 7/1.70 1,272 22.4 25 0.9 1.15 119 SWALSHF4X25 4 x 25 7/2.14 1,940 27.0 32 1.0 0.727 152 SWALSHF4X35 4 x 35 7/2.52 2,390 30.1 32 1.2 0.524 182 SWALSFH4X50 4 x 50 19/1.78 2,925 31.5 32 1.4 0.387 217 4 Core: Brown, Black, Grey & Blue SWALSHF4X70 4 x 70 19/2.14 4,200 37.4 40 1.6 0.268 266 SWALSHF4X95 4 x 95 19/2.52 5,355 40.9 50s 1.8 0.193 319 SWALSHF4X120 4 x 120 37/2.03 6,925 46.6 50 2.0 0.153 363 54

Part number Cross section 2 4 Core: Brown, Black, Grey & Blue Stranding Approx weight Approx overall diameter Gland size Single cleat Nom. Max. DC-resist conductor 20 o C ohm/km Current rating laid direct amp SWALSHF4X150 4 x 150 37/2.25 8,200 50.2 50s 2.0 0.124 406 SWALSHF4X185 4 x 185 37/2.52 9,975 55.8 63s TC9 0.0991 458 SWALSHF4X240 4 x 240 61/2.52 12,700 62.5 63 TC10 0.0754 529 SWALSHF4X300 4 x 300 61/2.85 15,275 67.4 75s TC11 0.0601 592 SWALSHF4X400 4 x 400 61/3.20 19,875 77.0 75 TC12 0.0470 667 5 Core: White Numbered Cores with Black Print SWALSHF5X1.5 5 x 1.5 7/0.53 395 13.72 20s 0.6 12.10 32 SWALSHF5X2.5 5 x 2.5 7/0.67 497 15.46 20s 0.6 7.41 42 SWALSHF5X4.0 5 x 4.0 7/0.85 674 17.38 20 0.7 4.61 55 SWALSHF5X6.0 5 x 6.0 7/1.04 868 19.05 20 0.8 3.08 69 SWALSHF5X10 5 x 10 7/1.35 1,197 22.06 25 0.9 1.83 92 SWALSHF5X16 5 x 16 7/1.70 1,780 24.14 25 1.1 1.15 119 SWALSHF5X25 5 x 25 7/2.14 2,435 28.4 32 1.2 0.727 152 SWALSHF5X35 5 x 35 7/2.52 2,800 33 40 1.4 0.524 182 SWALSHF5X50 5 x 50 19/1.78 3,850 38.0 40 1.6 0.387 217 SWALSHF5X70 5 x 70 19/2.14 5,100 42.9 50s 1.8 0.268 266 SWALSHF5X95 5 x 95 19/2.52 7,700 52.1 50 TC9 0.193 319 SWALSHF5X120 5 x 120 37/2.03 9,035 56.7 63s TC9 0.153 363 SWALSHF5x150 5 x 150 37/2.25 10,755 64.31 63 TC11 0.124 406 7 Core: White Numbered Cores with Black Print SWALSHF7X1.5 7 x 1.5 7/0.53 449 14.65 20s 0.6 12.10 32 SWALSHF7X2.5 7 x 2.5 7/0.67 564 16.53 20 0.8 7.41 42 SWALSHF7X4.0 7 x 4.0 7/0.85 824 18.96 20 0.8 4.61 55 SWALSHF7X6.0 7 x 6.0 7/1.04 1,105 21.6 25 0.9 3.08 69 SWALSHF7X10 7 x 10 7/1.35 1,610 25.3 25 1 1.83 98 SWALSHF7X16 7 x 16 7/1.70 2,225 28.45 32 1.2 1.15 119 SWALSHF7X25 7 x 25 7/2.14 3,880 38.4 32 1.4 0.727 152 12 Core: White Numbered Cores with Black Print SWALSHF12X1.5 12 x 1.5 7/0.53 756 18.9 25 0.8 12.10 32 SWALSHF12X2.5 12 x 2.5 7/0.67 971 21.76 25 0.9 7.41 42 SWALSHF12X4.0 12 x 4.0 7/0.85 1,403 25.97 25 1.0 4.61 55 SWALSHF12X6.0 12 x 6.0 7/1.04 1,910 28.1 32 1.2 3.08 69 SWALSHF12X10 12 x 10 7/1.35 2,590 32.4 32 1.4 1.83 98 19 Core: White Numbered Cores with Black Print SWALSHF19X1.5 19 x 1.5 7/0.53 992 21.99 25 0.9 12.10 32 SWALSHF19X4.0 19 x 4.0 7/0.85 1,870 28.46 32 1.1 4.61 55 SWALSHF27X1.5 27 x 1.5 7/0.53 1,470 21.99 25 1 12.10 32 POWER CABLES 55

Low Voltage Power Cable POWER CABLES Part number Cross section 2 Stranding Approx weight 27 Core: White Numbered Cores with Black Print Approx overall diameter Gland size Single cleat Nom. Max. DC-resist conductor 20 o C ohm/km Current rating laid direct amp SWALSHF27X2.5 27 x 2.5 7/0.67 1,905 30.1 32 1.2 7.41 42 SWALSHF27X4.0 27 x 4.0 7/0.85 2,495 33.2 32 1.4 4.61 55 37 Core: White Numbered Cores with Black Print SWALSHF37X1.5 37 x 1.5 7/0.53 1,640 21.99 32 1.1 12.10 32 SWALSHF37X2.5 37 x 2.5 7/0.67 2,363 30.1 40 1.4 7.41 42 SWALSHF37X4.0 37 x 4.0 7/0.85 3,090 33.2 40 1.4 4.61 55 48 Core: White Numbered Cores with Black Print SWALSHF48X1.5 48 x 1.5 7/0.53 2,175 30.0 40 1.2 12.10 32 SWALSHF48X2.5 48 x 2.5 7/0.67 3,115 37.4 40 1.6 7.41 42 SWALSHF48X4.0 48 x 4.0 7/0.85 4,110 44.5 50s 1.8 4.61 55 Suitable gland types: BW LSF: Internal use only CW LSF: Internal and external E1W: External double compression E1WF: Flameproof 56

Single Core Medium Voltage Power Cable BS6622 Cu/XLPE/CTS/PVC/AWA/PVC 6.36/11kV Cable Application Cu/XLPE/CTS/PVC/SWA/PVC 11kV medium voltage power cable may be used for power networks, in fixed installation outdoors in cable ducts or directly in the ground. The cable consists of a Class 2 stranded copper conductor, semi conductive conductor screen, XLPE insulation, semi conducting layer with a plain copper tape screen, PVC bedding, Aluminium Wire Armour and red PVC outer sheath. 6350/11000 volts to BS6622 and IEC 60502-2, flame retardant to IEC 60332-1. Technical Information Conductor Material: Copper Conductor Identification: Coloured tape under screen Conductor Shape: Circular Conductor Flexibility: Stranded class 2 Material of the Inner Semi-conductor: Semi-conducting compound Insulation: XLPE (Chemical) Armour Type: Aluminium wires Screen: Copper tape Outer Sheath: PVC Inner Sheath: PVC Material of the External Semi-conduct: Extruded strippable Colour: Red Lead Free: Yes Rated Voltage Uo/U (Um): 6350/11000V to BS6622 & IEC 60502-2 Installation Temperature: Minimum: 0 C Maximum: 60 C Installation Type: Direct burial or in ducts Operating Temperature: Minimum: -15 C Maximum: 90 C Short-circuit Maximum Conductor Temperature: 250 C Flame Retardant: Yes, IEC 60332-1 Bending Radius: 15 x Ø POWER CABLES Part number Cross section 2 Stranding Approx weight Approx overall diameter Gland size Single cleat Nom. Max. DC-resist conductor 20 o C ohm/km Current rating laid direct amp 1 Core: Brown Tape 11KVPVC1X50 1 x 50 19/1.78 1,210 28.5 32 1.2 0.387 221 11KVPVC1X70 1 x 70 19/2.14 1,500 30.5 32 1.2 0.268 270 11KVPVC1X95 1 x 95 19/2.52 1,700 32.4 32 1.4 0.193 321 11KVPVC1X120 1 x 120 37/2.03 2,105 34.2 40 1.4 0.153 363 11KVPVC1X150 1 x 150 37/2.25 2,505 36.4 40 1.6 0.124 410 11KVPVC1X185 1 x 185 37/2.52 2,900 37.7 40 1.6 0.0991 455 11KVPVC1X240 1 x 240 61/2.25 3,532 40.6 50s 1.6 0.0754 520 11KVPVC1X300 1 x 300 61/2.52 4,230 42.7 50s 1.8 0.0601 580 Medium Voltage Power Cable 57

Single Core Medium Voltage Power Cable POWER CABLES Part number 1 Core: Brown Tape Cross section 2 Stranding Approx weight Approx overall diameter Gland size Single cleat Nom. Max. DC-resist conductor 20 o C ohm/km Current rating laid direct amp 11KVPVC1X400 1 x 400 61/2.85 5,145 46.4 50s 2.0 0.0470 650 11KVPVC1X500 1 x 500 61/3.20 6,450 51.0 50 2.0 0.0366 710 11KVPVC1X630 1 x 630 127/2.52 7,950 59.9 63s R9 0.0283 761 11KVPVC1X800 1 x 800 127/2.85 9,720 60.0 63 R10 0.0221 812 11KVPVC1X1000 1 x 1000 127/3.2 11,860 64.0 75s R11 0.0176 868 Also available in a low smoke halogen free version. 58

3 Core Medium Voltage Power Cable BS6622 Cu/XLPE/CTS/PVC/SWA/PVC 6.36/11kV Cable Application Cu/XLPE/CTS/PVC/SWA/PVC 11kV medium voltage power cable may be used for power networks, in fixed installation outdoors, in cable ducts, or directly in the ground. The cable consists of a Class 2 stranded copper conductor, semi conductive conductor screen, XLPE insulation, semi conductive insulation screen, plain copper tape screen for each core, PVC bedding, galvanized steel wire armour and red PVC outer sheath. 6350/11000 volts to BS6622 and IEC 60502-2, flame retardant to IEC 60332-1. Technical Information Conductor Material: Copper Conductor identification: Coloured tapes under screen Conductor Shape: Circular Conductor Flexibility: Stranded class 2 Material of the Inner Semi-conductor: Semi-conducting compound Insulation: XLPE (Chemical) Armour Type: Galvanized steel wires Screen: Bare Copper Outer Sheath: PVC Inner Sheath: PVC Material of the External Semi-conduct: Extruded strippable Colour: Red Lead Free: Yes Rated Voltage Uo/U (Um): 6350/11000V to BS6622 & IEC 60502-2 Installation Temperature: Minimum: 0 C Maximum: 60 C Installation Type: Direct burial or in ducts Operating Temperature: Maximum: 90 C Short-circuit Maximum Conductor Temperature: 250 C Flame Retardant: IEC 60332-1 Bending Radius: 12 x Ø POWER CABLES Part number Cross section 2 Stranding Approx weight Approx overall diameter Gland size Single cleat Nom. Max. DC-resist conductor 20 o C ohm/km Current rating laid direct amp 3 Core: Brown, Black & Grey Tapes 11KVPVC3X16 3 x 16 7/1.70 3,440 44.3 40 1.8 1.15 119 11KVPVC3X25 3 x 25 7/2.14 4,060 48.5 50 2 0.727 152 11KVPVC3X35 3 x 35 7/2.52 4,495 50.5 50 R9 0.524 181 11KVPVC3X50 3 x 50 19/1.78 5,115 53.0 63s R9 0.387 213 11KVPVC3X70 3 x 70 19/2.14 6,035 56.8 63s R10 0.268 260 11KVPVC3X95 3 x 95 19/2.52 7,180 61.3 63 R10 0.193 309 11KVPVC3X120 3 x 120 37/2.03 8,280 65.1 75s R11 0.153 349 11KVPVC3X150 3 x 150 37/2.25 9,325 66.8 75s R11 0.124 390 3 Core Medium Voltage Power Cable 59

3 Core Medium Voltage Power Cable POWER CABLES Part number Cross section 2 Stranding 3 Core: Brown, Black & Grey Tapes Approx weight Approx overall diameter Gland size Single cleat Nom. Max. DC-resist conductor 20 o C ohm/km Current rating laid direct amp 11KVPVC3X185 3 x 185 37/2.52 10,740 72.3 75 R12 0.0991 436 11KVPVC3X240 3 x 240 61/2.52 13,820 79.3 90 R14 0.0754 499 11KVPVC3X300 3 x 300 61/2.85 16,120 84.2 90 R15 0.0754 553 11KVPVC3X400 3 x 400 61/3.20 19,350 92.4 - R15 0.0470 619 On request the cable is available with a black polyethylene (PE) outer sheath. A MMQ and manufacturing lead-time may apply. Also available in a low smoke halogen free version. 60

PVC Single Core Cable 6491X Cu/PVC 450/750V Cable Application 6491X H07V-R cable is suitable for power, lighting networks, switchgear, control gear and internal wiring. The PVC earthing cable is suitable for use in conduit and for fixed protected installation. The class 1 or 2 plain annealed copper conductor is PVC insulated. Available in a variety of colours, the PVC insulated non-armoured cable complies with 450/750 volts BS6004. Technical Information Conductor Material: Copper, BS6004 Table 4a Conductor Shape: Stranded circular Outer Sheath: PVC (Polyvinyl-Chloride) Colour: 1.5 & 2.5: Brown, black, blue, grey, green/yellow (earth), orange, red & white 4.0 up to 630: brown, black, blue, grey and green/yellow (earth) Lead Free: Yes Rated Voltage Uo/U (Um): 450/750V, BS6004 Installation Temperature: Minimum: 0 C Maximum: 60 C Operating Temperature: Minimum: -15 C Maximum: 70 C Short-circuit Maximum Conductor Temperature: 250 C Installation Type: Conduit wiring Flame Retardant: BS EN 50265 Bending Radius: 1.5² up to 25² = 3 x Ø 35² up to 240² = 4 x Ø 240² up to 630² = 6 x Ø POWER CABLES Part number Cross section 2 Stranding Approx weight Approx overall diameter Nylon A2 Gland size Nom. Max. DC-resist conductor 20 o C ohm/km Current rating laid direct amp Singlephase a.c. or d.c. amp Threephase a.c. amp 6491X / H07V-R 6491X1.5+ 1 x 1.5 7/0.53 20.5 2.9 16 12.10 17.5 15.5 6491X1.5*+ 1 x 1.5 1/1.38 21 2.8 16 12.10 17.5 15.5 6491X2.5+ 1 x 2.5 7/0.67 33.5 3.53 16 7.41 24 21 6491X2.5*+ 1 x 2.5 1/1.78 35 3.4 16 7.41 24 21 6491X4.0+ 1 x 4.0 7/0.85 49.5 4.4 16 4.61 32 28 6941X6.0+ 1 x 6.0 7/1.04 70 4.68 16 3.08 41 36 6491X10+ 1 x 10 7/1.35 117 5.98 16 1.83 57 50 6491X16+ 1 x 16 7/1.70 176 6.95 16 1.15 76 68 6491X25+ 1 x 25 7/2.14 274 8.7 20 0.727 101 89 6491X35+ 1 x 35 7/2.52 378 10.08 20 0.524 125 110 6491X50+ 1 x 50 19/1.78 560 11.8 20 0.387 151 134 PVC Single Core Cable 61

PVC Single Core Cable POWER CABLES Part number 6491X / H07V-R Cross section 2 Stranding Approx weight Approx overall diameter Nylon A2 Gland size Nom. Max. DC-resist conductor 20 o C ohm/km Current rating laid direct amp Singlephase a.c. or d.c. amp Threephase a.c. amp 6491X70+ 1 x 70 19/2.14 718 13.5 25 0.268 192 171 6491X95+ 1 x 95 19/2.52 989 15.7 25 0.193 232 207 6491X120+ 1 x 120 37/2.03 1,213 17.4 25 0.153 296 239 6491X150+ 1 x 150 37/2.25 1,504 19.3 32 0.124 300 262 6491X185+ 1 x 185 37/2.52 1,899 21.5 32 0.0991 341 296 6491X240+ 1 x 240 61/2.25 2,482 24.6 32 0.0754 400 346 6491X300+ 1 x 300 61/2.52 3,040 27.9 40 0.0601 458 394 6491X400+ 1 x 400 61/3.85 3,948 30.8 40 0.047 546 467 6491X500+ 1 x 500 61/3.20 4,951 33.8 50 0.0366 626 533 6491X630+ 1 x 630 127/2.50 6,273 37.6 50 0.0283 720 611 * Solid conductor + Add colour you require For current ratings refer to IEE Regulations tables 4D1 and 2 pages 108 to 111. 62

LSHF Single Core Cable 6491B 450/750V Cable Application 6491B H07Z-R to BS7211 cable is suitable for power, conduit wiring, lighting networks, switchgear, control gear and internal wiring. The class 2 plain annealed copper conductor is LSHF (Low Smoke Halogen Free) insulated. Available in a variety of colours, the LSHF insulated non-armoured cable is designed for use in situations where smoke and acid gas emissions would be hazardous to people and equipment. Technical Information Conductor Material: Copper, BS EN 60228:2005 Conductor Shape: Stranded circular Outer Sheath: LSHF (Low Smoke Halogen Free) Colour: 1.5 & 2.5: Brown, black, blue, grey, green/yellow (earth), orange, red and white 4.0 up to 630: Brown, black, blue, grey and green/yellow (earth) Halogen Free: Yes Lead Free: Yes Rated Voltage Uo/U (Um): 450/750V Installation Temperature: Minimum: 0 C Maximum: 60 C Operating Temperature: Minimum: -20 C Maximum: 90 C Short-circuit Maximum Conductor Temperature: 250 C Installation Type: Conduit wiring Flame Retardant: IEC60332-1 Smoke Density: IEC61034 Gases Toxicity: Low toxicity to IEC60754 Gases Corrosivity: Low IEC 60754-2 Bending Radius: 1.5² up to 25² = 3 x Ø 35² up to 240² = 4 x Ø 240² up to 630² = 6 x Ø POWER CABLES Part number Cross section 2 Stranding Approx weight Approx overall diameter Nylon A2 Gland size Nom. Max. DC-resist conductor 20 o C ohm/km Current rating (enclosed in conduit) Singlephase a.c. or d.c. amp Threephase a.c. amp 6491B/H07Z-R to BS7211 6491B1.5+ 1 x 1.5 7/0.53 21 2.9 16 12.1 22 10 6491B2.5+ 1 x 2.5 7/0.67 34.5 3.53 16 7.41 30 26 6491B4.0+ 1 x 4.0 7/0.85 50 4.4 16 4.61 40 35 6941B6.0+ 1 x 6.0 7/1.04 70 4.68 16 3.08 51 45 6491B10+ 1 x 10 7/1.35 119 5.98 16 1.83 71 63 6491B16+ 1 x 16 7/1.70 179 6.95 16 1.15 95 85 LSZH Single Core Cable 63

LSHF Single Core Cable POWER CABLES Part number Cross section 2 6491B/H07Z-R to BS7211 Stranding Approx weight Approx overall diameter Nylon A2 Gland size Nom. Max. DC-resist conductor 20 o C ohm/km Current rating (enclosed in conduit) Singlephase a.c. or d.c. amp Threephase a.c. amp 6491B25+ 1 x 25 7/2.14 278 8.7 20 0.727 126 111 6491B35+ 1 x 35 7/2.52 378 10.08 20 0.524 156 138 6491B50+ 1 x 50 19/1.78 562 11.8 20 0.387 189 168 6491B70+ 1 x 70 19/2.14 719 13.5 25 0.268 240 214 6491B95+ 1 x 95 19/2.52 991 15.7 25 0.193 290 259 6491B120+ 1 x 120 37/2.03 1,217 17.4 25 0.153 336 299 6491B150+ 1 x 150 37/2.25 1,508 19.3 32 0.124 375 328 6491B185+ 1 x 185 37/2.52 1,902 21.5 32 0.0991 426 370 6491B240+ 1 x 240 61/2.25 2,486 24.6 32 0.0754 450 433 6491B300+ 1 x 300 61/2.52 3,042 27.9 40 0.0601 573 493 6491B400+ 1 x 400 61/3.85 3,953 30.8 40 0.047 683 584 6491B500+ 1 x 500 61/3.20 4,957 33.8 50 0.0366 783 666 6491B630+ 1 x 630 127/2.50 6,279 37.6 50 0.0283 900 764 + Add colour you require For current ratings refer to IEE Regulations tables 4E1 and 2 pages 112 to 117. 64

Bare Copper Single Core Cable Stranded Bare Copper 0.6/1kV Cable Application Stranded Class 2 bare copper wire to BS EN 60228 cables are non insulated and non sheathed soft drawn copper to BS6360/81. Technical Information Conductor Material: Copper, BS EN 60228:2005 Conductor Shape: Stranded Circular Halogen Free: Yes Lead Free: Yes Rated Voltage Uo/U (Um): 600/1000V Minimum Installation Temperature: Minimum: 0 C Maximum: 60 C Minimum Operating Temperature: Minimum: -15 C Maximum: 70 C Short-circuit Maximum Conductor Temperature: 250 C Installation Type: Earthing/circuit grounding Flame Retardant: IEC60332-1 Bending Radius: 1.5² up to 25² = 3 x Ø 35² up to 400² = 6 x Ø POWER CABLES Part number Cross section 2 Soft Drawn Bare Copper to BS6360/81 Stranding Approx weight Approx overall diameter BC6.0 1 x 6.0 7/1.04 58 3.0 BC10 1 x 10 7/1.35 96 4.2 BC16 1 x 16 7/1.70 154 5.1 BC25 1 x 25 7/2.14 240 5.9 BC35 1 x 35 7/2.52 336 7.8 BC50 1 x 50 19/1.78 480 8.8 BC70 1 x 70 19/2.14 672 9.8 BC95 1 x 95 19/2.52 912 12.5 BC120 1 x 120 37/2.03 1152 12.8 BC150 1 x 150 37/2.25 1440 14.4 BC185 1 x 185 37/2.52 1776 16.1 BC240 1 x 240 61/2.25 2304 19.8 BC300 1 x 300 61/2.52 2800 20.6 BC400 1 x 400 61/2.85 3750 26.4 Bare Copper Single Core Cable 65

NYY Power Cable 0.6/1kV POWER CABLES Cable Application NYY is used as a power cable for energy supply in static installations, indoors, outdoors, underground, in concrete and in water where mechanical damages are not to be expected. The use of NYY cables is in accordance with VDE 0298 part 1. The current capacity is according to HD 603 S.1 and VDE 0276 part 1000. The product conforms to EEC directive 73/23 (Low Voltage Directive). CE. Technical Information Conductor: Plain copper to IEC 60228 class 1 or 2 Insulation: PVC Bedding: PVC Sheath: PVC sheath, black Cores: Colour coded to VDE0293 Voltage Rating: 0.6/1kV Bending Radius for Single Core: Minimum: 15 x Ø Bending Radius for Multi Core: Minimum:12 x Ø O = no earth J = +green/yellow earth NYY Power Cable Number of cores and 2 per conductor NYY-0 Approximate outside in ca. Copper weight Approximate weight ca. 1 x 6 re 9 58.0 140 1 x 10 re 10 96.0 190 1 x 16 re 11 154.0 240 1 x 25 rm 13 240.0 360 1 x 35 rm 14 336.0 470 1 x 50 rm 15 480.0 640 1 x 70 rm 17 672.0 850 1 x 95 rm 19 912.0 1,120 1 x 120 rm 21 1,152.0 1,370 1 x 150 rm 23 1,440.0 1,700 1 x 185 rm 25 1,776.0 2,100 1 x 240 rm 28 2,304.0 2,700 1 x 300 rm 30 2,880.0 3,200 1 x 500 rm 39 4,800.0 5,400 2 x 1.5 re 11 29.0 170 2 x 2.5 re 12 48.0 220 2 x 4 re 14 77.0 290 2 x 6 re 15 115.0 360 2 x 10 re 17 192.0 480 2 x 16 re 19 307.0 660 3 x 15 re 12 43.0 200 3 x 2.5 re 13 72.0 260 3 x 4 re 15 115.0 330 66

Number of cores and 2 per conductor NYY-0 Approximate outside in ca. Copper weight Approximate weight ca. 3 x 6 re 16 173.0 430 3 x 10 re 18 288.0 590 3 x 16 re 20 461.0 810 4 x 1.5 re 13 58.0 230 4 x 2.5 re 14 96.0 300 4 x 4 re 16 154.0 400 4 x 6 re 17 230.0 510 4 x 10 re 19 384.0 720 4 x 16 re 22 614.0 1,050 4 x 25 rm 28 960.0 1,650 4 x 35 sm 28 1,344.0 2,000 4 x 50 sm 31 1,920.0 2,700 4 x 70 sm 35 2,688.0 3,600 4 x 95 sm 40 3,648.0 4,800 5 x 1.5 re 14 72.0 270 5 x 2.5 re 15 120.0 350 NYY-J Voltage Rating 0.6/1kV 1 x 25 rm 13 240.0 360 1 x 35 rm 14 336.0 470 1 x 50 rm 15 480.0 640 1 x 70 rm 17 672.0 850 3 x 1.5 re 12 43.0 200 3 x 2.5 re 13 72.0 260 3 x 4 re 15 115.0 330 3 x 6 re 16 173.0 430 3 x 10 re 18 288.0 590 3 x 16 re 20 461.0 810 3 x 25 rm /16 re 26 874.0 1,520 3 x 35 sm/16 re 28 1,162.0 1,800 3 x 50 sm/25 rm 31 1,680.0 2,500 3 x 70 sm/35 sm 35 3,252.0 3,300 3 x 95 sm/50 sm 40 3,216.0 4,400 3 x 120 sm/70 sm 43 4,128.0 5,400 3 x 150 sm/70 sm 48 4,992.0 6,700 3 x 185 sm/95 sm 52 6,240.0 8,000 3 x 240 sm/120 sm 59 8,064.0 10,400 3 x 300/150 sm 65 10,080.0 13,000 4 x 1.5 re 13 58.0 230 4 x 2.5 re 14 96.0 300 POWER CABLES 67

NYY Power Cable 0.6/1kV POWER CABLES Number of cores and 2 per conductor NYY-J Voltage Rating 0.6/1kV Approximate outside in ca. Copper weight Approximate weight ca. 4 x 4 re 16 154.0 400 4 x 6 re 17 230.0 510 4 x 10 re 19 384.0 720 4 x 16 re 22 614.0 1,050 4 x 25 rm 28 960.0 1,650 4 x 35 sm 28 1,344.0 2,000 4 x 50 sm 31 1,920.0 2,700 4 x 70 sm 35 2,688.0 3,600 4 x 95 sm 40 3,648.0 4,800 4 x 120 sm 43 4,608.0 5,900 4 x 150 sm 48 5,760.0 7,300 4 x 185 sm 53 7,104.0 9,000 4 x 240 sm 60 9216.0 11,400 5 x 1.5 re 14 72.0 270 5 x 2.5 re 15 120.0 350 5 x 4 re 17 192.0 480 5 x 6 re 19 288.0 610 5 x 10 re 21 480.0 880 5 x 16 re 24 768.0 1,250 7 x 1.5 re 15 101.0 300 10 x 1.5 re 17 144.0 420 12 x 1.5 re 18 173.0 460 14 x 1.5 re 19 202.0 520 16 x 1.5 re 20 230.0 570 19 x 1.5 re 21 274.0 600 21 x 1.5 re 22 302.0 650 24 x 1.5 re 23 346.0 750 30 x 1.5 re 25 432.0 800 40 x 1.5 re 28 576.0 1,050 52 x 1.5 re 31 749.0 1,450 61 x 1.5 re 33 878.0 1,680 7 x 2.5 re 16 168.0 420 10 x 2.5 re 19 240.0 600 12 x 2.5 re 21 288.0 630 14 2.5 re 22 336.0 740 16 x 2.5 re 23 384.0 810 19 x 2.5 re 24 456.0 850 21 x 2.5 re 25 504.0 950 24 x 2.5 re 27 576.0 1,100 68

Number of cores and 2 per conductor NYY-J Voltage Rating 0.6/1kV Approximate outside in ca. Copper weight Approximate weight ca. 30 x 2.5 re 29 720.0 1,300 40 x 2.5 re 32 960.0 1,700 52 x 2.5 re 36 1,248.0 2,200 re = round conductor, single wire rm = round conductor, multi wire sm = sectorial conductor POWER CABLES Also available in low smoke halogen free versions. 69

NYCY Energy Cable POWER CABLES Cable Application NYCY cable and NYCWY cable is used as a energy supply cables for power stations, street lighting and underground and in water. For static installation where no mechanical damage is expected. As well as control distribution boards cable where increased electrical and mechanical protection is required. Technical Information Conductor: According to VDE 0295 and IEC 60228, class 1 single wire conductors Core insulation: PVC and colour coded to VDE 0293, more than 6 cores number coded Bedding: PVC Concentric Conductor: Stranded concentrically Concentric conductors in inner layer of round copper wires, outer layer with copper tape Outer Sheath: PVC Black Voltage Rating: 0.6-1kV Temperature Range: Flexing: - 5 C to + 50 C Static: -30 C to + 70 C Bending Radius: Single conductor 15 x Ø Multi conductor 12 x Ø Core Marketing NYY-J: With protective earth NYCY Energy Cable Number of cores and cross section 2 Copper weight Approximate outside in ca. Approximate weight kg/100m 2 x 1.5 RE /1.5 52.0 13.0 245 3 G 1.5 RE/1.5 66.0 14.0 290 4 G 1.5 RE/1.5 81.0 15.0 330 7 G 1.5 RE/2.5 133.0 17.0 440 10 G 1.5 RE/2.5 176.0 19.0 550 12 G 1.5 RE/2.5 205.0 20.0 620 14 G 1.5 RE/2.5 235.0 21.0 680 19 G 1.5 RE/4 320.0 23.0 840 24 G 1.5 RE/6 415.0 26.0 1,030 30 G 1.5 RE/6 500.0 27.0 1,180 40 G 1.5 RE/10 696.0 30.0 1,500 2 x 2.5 RE/2.5 80.0 14.0 310 3 G 2.5 RE/2.5 105.0 15.0 350 4 G 2.5 RE/2.5 128.0 16.0 410 7 G 2.5 RE/2.5 200.0 18.0 540 10 G 2.5 RE/4 286.0 21.0 730 12 G 2.5 RE/4 334.0 22.0 800 14 G 2.5 RE/6 403.0 23.0 900 19 G 2.5 RE6 523.0 25.0 1,090 24 G 2.5 RE/10 696.0 28.0 1,370 30 G 2.5 RE/10 840.0 30.0 1,580 40 G 2.5 RE/10 1,080.0 33.0 1,970 3 G 4 RE/4 161.0 16.0 480 4 G 4 RE / 4 200.0 18.0 550 70

Number of cores and cross section 2 NYCWY Cable * Copper weight Approximate outside in ca. Approximate weight kg/100m 3 G 6 RE / 6 240.0 18.0 590 4 G 6 RE / 6 297.0 19.0 690 2 G 10 RE/10 312.0 19.0 680 3 G 10 RE/10 408.0 20.0 780 4 G 10 RE/10 504.0 21.0 910 3 G 16 RE/16 643.0 22.0 1,100 4 G 16 RE/16 796.0 24.0 1,250 3 G 25 RM/25 1,003.0 27.0 1,650 4 G 25 RM/16 1,142.0 29.0 1,850 3 G 35 SM/16 1,190.0 26.0 1,170 3 G 35 SM/35 1,402.0 27.0 1,990 4 G 35 SM/16 1,526.0 29.0 2,150 3 G 50 SM/25 1,723.0 30.0 2,300 3 G 50 SM/50 2,000.0 31.0 2,500 4 G 50 SM/25 2,203.0 34.0 2,950 3 G 70 SM/35 2,410.0 34.0 3,150 3 G 70 SM/70 2,796.0 34.0 3,500 4 G 70 SM/35 3,082.0 38.0 3,950 3 G 95 SM/50 3,296.0 39.0 4,200 3 G 95 SM/95 3,791.0 39.0 4,700 4 G 95 SM/50 4,208.0 43.0 5,300 4 G 120 SM/70 5,388.0 47.0 6,650 4 G 150 SM/70 6,540.0 51.0 7,950 4 G 185 SM/95 8,159.0 57.0 9,900 POWER CABLES * As per NYCY cable but with an additional inner layer of corrugated copper wires with an outer layer of copper tape re = round conductor, solid rm = round conductor, stranded sm = sectorial conductor, stranded Also available in low smoke halogen free versions. 71

Alsecure NX200 Cable FIRE ALARM CABLES CSE Cables stock a wide range of fire resistant cables coonly known as soft skin cables. These cables are available in different versions and are designed to carry on functioning even in the event of a fire. Cable Application Alsecure NX200 is a standard fire resistant cable for fire alarm and emergency lighting installations complying with BS 5839 and BS 5266. Alsecure NX200 has been designed to be a highly user friendly, high performance Fire Resistant cable. NX200 meets and exceeds requirements of all applicable standards and carry independent third party certification. Alsecure NX200 is fully LUL and BASEC approved. To provide the ultimate ease and speed of installation, stripping of both insulation and sheath couldn t be easier. Just lightly ring the sheath and break it away together with the bonded aluminium foil. The most coon sizes have no additional binders or loose foils so the silicone conductor insulation can then be stripped off in an instant saving you time and money. Nexans Alsecure NX200 can be used for: AC and DV voltages of 300/500V. Fire detection and fire alarm critical signal path according to BS 5839-1:2002 + A2:2008 Standard application areas Voice alarm systems according to BS5839-8:2008 Emergency lighting systems according to BS5266-1:2005 Nexans Alsecure NX200 improved features: Speedy stripping and termination 120 minute circuit integrity (PH120 to BS EN 50200 & Annex E) > 60 min longer than most other standard fire resistant cables Halogen-free, flame retardant, low smoke, good chemical resistance When the protection of human life and sensitive electronic equipment is paramount, choosing the right materials is essential. As well as assuring the integrity of fire safety systems installing Alsecure NX200 also limits the effects of toxic fumes and smoke, thus aiding the facilitation of effective escape for people from a fire situation and reducing collateral damage to expensive equipment. Alsecure NX200 Cable 72

Types Approval BASEC LPCB Application Fire detection and fire alarm systems for buildings Public address systems Emergency lighting Design 1. Conductor: Bare copper, Solid Class 1 (1, 1.5 2 ), Stranded Class 2 (2.5 4 2 ) according to BS 6360/IEC 60228 FIRE ALARM CABLES 2. Insulation: Silicon rubber to BS 7655 3. Un-insulated Protective Conductor: Tinned copper according to BS6360: same class and cross sectional area as insulated conductor 4. Screen: Aluminium/polyester tape with optional polyester tape 5. Outer Sheath: Halogen free polyolefin Colour: red or white Technical Information Insulation: Armour Type: Outer Sheath: Marking: Silicone Aluminium tape HFFR (Halogene Free Flame Retardant) ALSECURE NX 200 - n x s 300/500V - BASEC - LPCB - BS 7629-1 - BS 6387 CWZ - BS 8434-1 - NEXANS - week/year Standards: BS 7629 Part 1 BS 5839-1: 2002 Cat. Standard Electrical Characteristics: Rated Voltage Uo/U 300/500 V Fire Resistant: BS 6387 CWZ, BS 8434-1: 2003, BS EN 50200 PH 30 Flame Retardant: BS EN 50265 1 & 2.1: IEC 60332 Part 1 Low Smoke: BS EN 50268: IEC 60754 Halogen Free: BS EN 50267: IEC 60754 Low Toxicity: BS EN 50267: IEC 60754 Low Corrosivity: BS EN 50267: IEC 60754 Temperature: -20 o C + 60 o C 73

Alsecure NX200 Cable FIRE ALARM CABLES Electrical Characteristics Fire Resistant: BS 6387 CWZ, BS EN 50200 PH 120 Fire Retardant: IEC 60332-1 Smoke Density: EN/IEC 61034-2 Operating Temperature: Maximum: 90 C Minimum: -25 C Bending Factor when Installed: 6(xD) Chemical Resistance: Good Rated Voltage Uo/U (Um): 300/500V Maximum Operating Voltage: 500V Test Voltage: 2000V Core Identification Two Cores: Three Cores: Four Cores: Brown - blue Brown - black - grey Brown - black - grey - blue Stock info Made to order Made to order Made to order In stock In stock In stock In stock In stock Made to order In stock Made to order In stock Made to order Product name NX200 2 x 1 NX200 3 x 1 NX200 4 x 1 NX200 2 x 1.5 NX200 3 x 1.5 NX200 4 x 1.5 NX200 2 x 2.5 NX200 3 x 2.5 NX200 4 x 2.5 NX200 2 x 4 NX200 4 x 4 NX200 7 x 1.5 NX200 12 x 1.5 No. of cores n Nom. cross section 2 Nom. outer diam. Cable weight approx. Conductor class Maximum conductor resistance Ω/km Current rating DC or single phase AC enclosed Apms Current rating DC or single phase AC direct clipped Apms Voltage drop DC or single core AC mv/ A/m 2 1 8 79 1 18.1 17 19 46 3 1 8.4 97 1 18.1 17 19 46 4 1 9.3 122 1 18.1 17 19 46 2 1.5 8 89 1 12.1 22 24 31 3 1.5 8.4 110 1 12.1 22 24 31 4 1.5 9.5 133 1 12.1 22 24 31 2 2.5 9.3 126 1 7.41 30 33 19 3 2.5 10.1 161 1 7.41 30 33 19 4 2.5 11.2 201 1 7.41 30 33 19 2 4 11.3 196 2 4.61 40 45 12 4 4 14.1 315 2 4.61 40 45 12 7 1.5 11.8 221 1 - - - - 12 1.5 14.8 340 1 - - - - 74

Stock info Product name 4 Conductors + Made to order Made to order NX200 19 x 1.5 NX200 7 x 2.5 NX200 12 x 2.5 NX200 19 x 2.5 No. of cores n Nom. cross section 2 Nom. outer diam. Cable weight approx. Conductor class Maximum conductor resistance Ω/km Current rating DC or single phase AC enclosed Apms Current rating DC or single phase AC direct clipped Apms Voltage drop DC or single core AC mv/ A/m 19 1.5 17.5 510 1 - - - - 7 2.5 13.7 310 1 - - - - 12 2.5 17.9 490 1 - - - - 19 2.5 20.8 810 1 - - - - FIRE ALARM CABLES Rating factor for different ambient temperature Ambient Temperature o C 25 30 35 40 45 50 55 Rating Factor 1.02 1.00 0.96 0.91 0.87 0.82 0.76 Rating factor for groups Number of circuits 1 2 3 4 5 6 7 Rating factor 1.00 0.80 0.70 0.65 0.60 0.57 0.54 75

NX200+ Cable FIRE ALARM CABLES BS 5839-1: 2002 Cat. Standard. 300/500 V. A fire resistant, fire retardant and low smoke cable for use in buildings where systems need to remain operational. Maximum conductor temperature is 70 o C. Types Approval BASEC LPCB Application Fire detection and fire alarm systems for buildings Public address systems Emergency lighting Design 1. Conductor: Bare copper, Solid Class 1 (1, 1.5 2 ), Stranded Class 2 (2.5 4 2 ) according to BS 6360/IEC 60228 2. Insulation: Silicon rubber to BS 7655 3. Un-insulated protective conductor: Tinned copper according to BS6360: same class and cross sectional area as insulated conductor 4. Screen: Aluminium/polyester tape with optional polyester tape 5. Outer sheath: Halogen free polyolefin Colour: Red Technical Information Marking: ALSECURE NX 200 - n x s 300/500 V - BASEC - LPCB - BS 7629-1 - BS 6387 CWZ - BS 8434-2 - NEXANS - week/year Standards: BS 7629 Part 1 BS 5839-1: 2002 Cat. Enhanced Electrical Characteristics: Rated Voltage Uo/U 300/500 V Fire Resistant: BS 6387 CWZ, BS 8434-2: 2003, BS EN 50200 PH 120 Flame Retardant: BS EN 50265 1 & 2.1: IEC 60332 Part 1 Low Smoke: BS EN 50268: IEC 61034 Halogen Free: BS EN 50267: IEC 60754 Low Toxicity: BS EN 50267: IEC 60754 Low Corrosivity: BS EN 50267: IEC 60754 Temperature: -20 o C + 60 o C NX200+ Cable Core Identification Two Cores: Three Cores: Four Cores: Brown-blue Brown-black-grey Brown-black-grey-blue 76

SIF Cable Silicone Single Core Stranded Cable Cable Application Suitable where PVC insulated cables become brittle due to high temperature variations. Silicone insulated single cores are preferably used in the metallurgical industry, steel works, hot rolling mills, coking plants, foundries etc. Applications can include the internal wiring of equipment, appliances, control cabinets, ceramics and foundries where high temperatures occur. Insulation consists of silicone rubber. It is resistant to vegetable and animal fat, many types of oil and diluted acids. No decomposition occurs when exposed to alcohol, alkaline solutions, etc. The insulation is resistant to oxygen and ozone. Should the cable burn, an insulation silicone dioxide layer will remain on the conductor to render it short circuit proof. Technical Information Conductor: Tinned copper conductor Insulation: Silicone rubber Stranding: According to VDE 0295 class 5, 60228 Voltage Rating: 300/500V Temperature Range: Flexing: -50 o C to + 180 o C Temporarily: to +200 o C Bending Radius: Flexing: 15 x Ø Static: 7.5 x Ø HIGH TEMPERATURE CABLES Stranding Nominal O/DIA Weight 0.25-1.9 5.4 0.5 16/0.20 2.1 8 0.75 24/0.20 2.4 11 1 32/0.20 2.5 14 1.5 30/0.25 2.8 19 2.5 50/0.25 3.4 30 4 56/0.30 4.2 48 6 84/0.30 5.2 71 10 80/0.40 7 120 16 126/0.40 8.4 180 25 196/0.40 10.3 290 35 270/0.40 11.6 400 50 396/0.40 13.9 550 70 360/0.50 16 750 95 475/0.50 18.4 1,000 120-20.0 1,285 150-23.0 1,563 185-24.9 1,915 240-26.9 2,550 300-30.1 3,190 400-36.3 4,130 500-40.3 5,210 For the current ratings refer to the IEE Regulations tables 4F2A and B on pages 124 to 126. SIF Cable 77

SIF GL Cable HIGH TEMPERATURE CABLES Silicone Single Core with Glass Fibre Braiding Cable Cable Application Suitable where PVC insulated cables become brittle due to high temperature variations. Silicone insulated single cores are preferably used in the metallurgical industry, steel works, hot rolling mills, coking plants, foundries etc. Applications can include the internal wiring of equipment, appliances, control cabinets, ceramics and foundries where high temperatures occur. Insulation consists of silicone rubber. It is resistant to vegetable and animal fat, many types of oil and diluted acids. No decomposition occurs when exposed to alcohol, alkaline solutions, etc. The insulation is resistant to oxygen and ozone. Should the cable burn, an insulation silicone dioxide layer will remain on the conductor to render it short circuit proof. Additional mechanical protection due to the glass fibre braid. Technical Information Conductor: Fine strands of tinned copper wire Insulation: Silicone rubber (available in various colours) Braiding: Glass fibre braid Stranding: According to VDE 0295 class 5, IEC 60228 Voltage: Working: 300/500V Test: 2000V Temperature Range: Flexing: -60 o C to + 180 o C Temporarily: to +200 o C Bending Radius: Flexing: 15 x Ø Static: 7.5 x Ø Cross section 2 Outer diameter in ca. Copper weight Weight ca. 0.25 2.4 2.4 7.9 0.5 2.6 4.8 12.6 0.75 2.9 7.2 16.0 1.0 3.0 9.6 18.4 1.5 3.3 14.4 23.7 2.5 3.9 24.0 35.6 4.0 4.7 38.0 53.3 6.0 5.7 58.0 77.3 10.0 7.5 96.0 129.2 16.0 8.9 154.0 198.6 25.0 10.8 240 302.5 35.0 12.1 336.0 413.0 50.0 14.4 480.0 578.0 For the current ratings refer to the IEE Regulations tables 4F2A and B on pages 124 to 126. SIF GL Cable 78

SID Cable Cable Application Suitable where PVC insulated cables become brittle due to high temperature variations. Silicone insulated single cores are preferably used in the metallurgical industry, steel works, hot rolling mills, coking plants, foundries etc. Applications can include the internal wiring of equipment, appliances, control cabinets, ceramics and foundries where high temperatures occur. Insulation consists of silicone rubber. It is resistant to vegetable and animal fat, many types of oil and diluted acids. No decomposition occurs when exposed to alcohol, alkaline solutions, etc. The insulation is resistant to oxygen and ozone. Should the cable burn, an insulation silicone dioxide layer will remain on the conductor to render it short circuit proof. Suitable for fixed installation. Technical Information Conductor: Solid tinned copper wire Insulation: Silicone rubber Stranding: VDE 0295 class 1, IEC 60228 Voltage: Working: 300/500V Test: 2000V Temperature Range: Flexing: -60 o C to + 180 o C Temporarily: to +200 o C Bending Radius: 7.5 x Ø HIGH TEMPERATURE CABLES Cross section 2 Outer diameter in ca. Copper weight Weight ca. 0.5 2.0 4.8 7.7 0.75 2.2 7.2 10.4 1.0 2.3 9.6 12.8 1.5 2.6 14.4 18.0 2.5 3.2 24.0 28.9 4.0 3.9 38.0 45.4 6.0 4.4 58.0 64.5 For the current ratings refer to the IEE Regulations tables 4F2A and B on pages 124 to 126. SID Cable 79

SiHF Cable HIGH TEMPERATURE CABLES Cable Application Suitable where PVC insulated where PVC insulated cables become brittle due to high temperature variations. Silicone insulated single cores are coonly used in the metallurgical industry, steel works, hot rolling mills, coking plants, foundries etc. SiHFP cable can be used in dry, moist and wet rooms as well as outdoors at high and low temperatures, as a flexible connecting cable. The insulation consists of silicone rubber. It is resistant to vegetable and animal fat, many types of oil and diluted acids. No decomposition occurs when exposed to alcohol, alkaline solutions etc. The insulation is resistant to oxygen and ozone. Should the cable burn, a silicone dioxide layer will remain on the conductor to render it short circuit proof. Technical Information Conductor: Stranded tinned copper wire conductor Insulation: Silicone rubber Sheath: Silicone outer sheath, red - brown Stranding: According to VDE 0295 class 5, IEC 60228 Voltage: Working: 300/500V Test: 3000V Temperature Range: Flexing: -60 o C to +180 o C Temporarily: to +200 o C Bending Radius: Flexing: 15 x Ø Static: 7.5 x Ø Cores and size 2 Nominal O/DIA Weight ca. 2 x 0.75 6.4 53 2 x 1.0 6.6 60 2 x 1.5 7.6 82 2 x 2.5 9.2 135 3 x 0.75 6.8 64 3 x 1.0 7.4 78 3 x 1.5 8 98 3 x 2.5 9.7 152 3 x 4.0 11.4 220 3 x 6.0 14.2 338 4 x 0.75 7.8 84 4 x 1.0 8 95 4 x 1.5 8.8 120 4 x 2.5 10.6 189 4 x 4.0 13.1 295 Cores and size 2 Nominal O/DIA Weight ca. 4 x 6.0 16.2 440 4 x 10.0 20 700 4 x 16.0 24.3 985 5 x 0.75 8.5 100 5 x 1.0 8.9 115 5 x 1.5 9.6 148 5 x 2.5 11.6 229 5 x 4.0 14.4 359 7 x 0.75 9.2 125 7 x 1.0 9.5 144 7 x 1.5 10.4 187 7 x 2.5 12.6 293 12 x 1.5 14 332 18 x 1.5 17.3 420 24 x 1.5 20 635 Other sizes and colours available on request. For the current ratings refer to the IEE Regulations tables 4F2A and B to 4F3A and B on pages 124 to 128. SiHF Cable 80

SiHFP Cable Cable Application A high temperature silicone cable with steel wire braid - suitable for industrial areas where PVC insulated cables become brittle with increased temperature and mechanical requirements for example mechanical engineering, glass and ceramic fabrication and steel / iron fabrication. The steel wire braid protects the sheath against mechanical stress. Should the cable burn, an insulation silicon dioxide layer will remain on the conductor to render it short circuit proof. Technical Information Conductor: Insulation Resistance: Armouring: Sheath: Colours: Twisting: Stranded conductor of tinned copper wire According to VDE 0295 class 5, IEC 60228 Minimum 20 MΩ x km at 20 o C Galvanised steel wire braid Silicone outer sheath, red - brown To VDE 0293, more than six cores black with printed numbers in layers Cores twisted in layers Rated Voltage U0/U: 300/500V Test Voltage: 2000V Temperature Range: -50 o C up to 180 o C Short term: +200 o C Minimum Bending Radius: Flexing: 20 x Ø Static: 10 x Ø Halogen Free: To VDE 0472 part 813 and IEC 754-1 HIGH TEMPERATURE CABLES Number of cores x cross section 2 Maximum Ω of single wire Maximum strand diameter Core diameter ± 5% o.d. ± 5% Copper weight Weight approx. 2 x 0.75 0.21 1.16 2.26 7.2 14.4 88 3 x 0.75 0.21 1.16 2.26 7.6 21.6 99 4 x 0.75 0.21 1.16 2.26 8.1 29 121 5 x 0.75 0.21 1.16 2.26 9.2 36 147 6 x 0.75 0.21 1.16 2.26 9.9 43 169 7 x 0.75 0.21 1.16 2.26 9.9 50 178 2 x 1 0.21 1.35 2.44 7.6 19 98 3 x 1 0.21 1.35 2.44 8.0 29 119 4 x 1 0.21 1.35 2.44 8.8 38 139 5 x 1 0.21 1.35 2.44 9.7 48 167 6 x 1 0.21 1.35 2.44 10.4 58 185 7 x 1 0.21 1.35 2.44 10.4 67 194 2 x 1.5 0.26 1.61 2.70 8.3 29 126 3 x 1.5 0.26 1.61 2.70 8.7 43 143 4 x 1.5 0.26 1.61 2.70 9.6 58 170 5 x 1.5 0.26 1.61 2.70 10.4 72 198 6 x 1.5 0.26 1.61 2.70 11.4 86 245 7 x 1.5 0.26 1.61 2.70 11.4 101 256 8 x 1.5 0.26 1.61 2.70 12.7 116 315 10 x 1.5 0.26 1.61 2.70 14.0 144 370 E & OE SiHFP Cable 81

SiHFP Cable HIGH TEMPERATURE CABLES Number of cores x cross section 2 E & OE Maximum Ω of single wire Maximum strand diameter Core diameter ± 5% o.d. ± 5% Copper weight Weight approx. 12 x 1.5 0.26 1.61 2.70 14.5 173 408 14 x 1.5 0.26 1.61 2.70 15.6 202 471 16 x 1.5 0.26 1.61 2.70 17.0 231 541 18 x 1.5 0.26 1.61 2.70 17.8 260 599 20 x 1.5 0.26 1.61 2.70 18.3 288 630 24 x 1.5 0.26 1.61 2.70 20.4 346 760 2 x 2.5 0.26 2.05 3.31 9.7 48 165 3 x 2.5 0.26 2.05 3.31 10.2 72 238 4 x 2.5 0.26 2.05 3.31 11.5 96 268 5 x 2.5 0.26 2.05 3.31 12.7 120 315 6 x 2.5 0.26 2.05 3.31 13.7 144 370 7 x 2.5 0.26 2.05 3.31 13.7 168 385 12 x 2.5 0.26 2.05 3.31 17.6 288 608 2 x 4 0.31 2.58 4.01 11.5 77 255 3 x 4 0.31 2.58 4.01 12.2 115 299 4 x 4 0.31 2.58 4.01 13.4 154 365 5 x 4 0.31 2.58 4.01 15.1 192 455 6 x 4 0.31 2.58 4.01 16.4 230 525 7 x 4 0.31 2.58 4.01 16.4 269 556 2 x 6 0.31 3.22 4.61 12.9 115 326 3 x 6 0.31 3.22 4.61 13.7 173 401 4 x 6 0.31 3.22 4.61 14.8 230 485 5 x 6 0.31 3.22 4.61 16.8 288 602 6 x 6 0.31 3.22 4.61 18.2 346 701 7 x 6 0.31 3.22 4.61 18.2 403 736 2 x 10 0.41 4.78 6.51 17.3 192 543 3 x 10 0.41 4.78 6.51 18.4 288 652 4 x 10 0.41 4.78 6.51 20.6 384 825 5 x 10 0.41 4.78 6.51 22.5 480 987 2 x 16 0.41 6.0 7.66 20.2 308 748 3 x 16 0.41 6.0 7.66 21.5 462 909 4 x 16 0.41 6.0 7.66 23.4 616 1183 5 x 16 0.41 6.0 7.66 26.2 770 1393 2 x 25 0.41 7.45 9.46 23.8 480 1046 3 x 25 0.41 7.45 9.46 26 720 1347 4 x 25 0.41 7.45 9.46 28.3 960 1678 2 x 35 0.41 8.93 10.86 27.2 672 1378 3 x 35 0.41 8.93 10.86 29 1008 1846 4 x 35 0.41 8.93 10.86 32.3 1344 2240 2 x 50 0.41 10.4 12.66 31.4 960 1869 82

Number of cores x cross section 2 E & OE Maximum Ω of single wire Maximum strand diameter Core diameter ± 5% o.d. ± 5% Copper weight Weight approx. 3 x 50 0.41 10.4 12.66 33.5 1440 2384 4 x 50 0.41 10.4 12.66 37.2 1920 2702 2 x 70 0.51 12.44 14.61 35.3 1344 2482 3 x 70 0.51 12.44 14.61 38.3 2016 3314 4 x 70 0.51 12.44 14.61 42.5 2688 4074 2 x 95 0.51 14.9 17.36 41.4 1824 3380 3 x 95 0.51 14.9 17.36 44.8 2736 4299 4 x 95 0.51 14.9 17.36 49.8 3648 5339 3 x 120 0.51 16.53 18.91 48.8 3465 5277 4 x 120 0.51 16.53 18.91 54.1 4620 6571 For the current ratings refer to the IEE Regulations tables 4F2A and B to 4F3A and B on pages 124 to 128. HIGH TEMPERATURE CABLES 83

Tri-Rated Panel Wires HIGH TEMPERATURE CABLES CSE Cables Ltd offer a range of PVC insulated flexible panel wires which are manufactured and recognised/certified as appropriate to the following standards: Underwriters Laboratories (UL): Recognised to Style 1015, 1028, 1283 or 1284 (depending on wire size) Rated: 105 o C in air 60 o C in oil 600V Canadian Standards Association (CSA): Certified to Type TEW 105 o C British Standard: Manufactured to BS6231 Type CK Applications include the wiring of switch, control metering, relay and instrument panels of power switchgear as well as internal connections in rectifier equipment and in motor starters and controllers. The UL and CSA certification on these wires enable their use in equipment destined for the North American market as well as the European market. This gives the benefit of simple design and manufacturing and less stockholding, compared to the alternative of using wires manufactured to the seperate standards. Wires are available in the following colours: Black, blue, light blue, dark blue, brown, green, grey, orange, pink, red, violet, white, yellow and green/yellow. Standard reels are available though other lengths can be supplied on request. Sizes up to and including 6 2 can be supplied in cardboard barrels. All reels and barrels carry UL and CSA certification labels. Technical Information Conductors: Plain annealed copper, class 5 to BS EN 60228 Insulation: Heat resisting PVC Maximum Conductor: Temperature: 105 o C in air, 60 o C in oil Voltage Rating: 600V between conductor and earth, 1000V between conductors Minimum Bending Radius: 6 x Ø Tri-Rated Panel Wires AWM size Size 2 Wire type UL style Nominal R/T Nominal diameter Current rating A Weight 22 0.5 16/0.2 1015 0.8 2.6 11 11 20 0.75 24/0.2 1015 0.8 2.8 14 14 18 1 32/0.2 1015 0.8 3.0 17 17 16 1.5 30/0.25 1015 0.8 3.3 21 27 14 2.5 50/0.25 1015 0.8 3.7 30 33 84

AWM size Size 2 Wire type UL style Nominal R/T Nominal diameter Current rating A Weight 12 4 56/0.3 1015 0.8 4.3 41 48 10 6 84/0.3 1015 0.8 5.1 53 71 8 10 80/0.4 1028 1.2 6.8 75 124 6 16 126/0.4 1283 1.58 9.2 100 199 4 25 196/0.4 1283 1.58 10.6 136 290 2 35 276/0.4 1283 1.58 11.6 167 387 1 50 396/0.4 1284 2.1 14.4 190 570 2/0 70 360/0.5 1284 2.1 16.5 240 781 3/0 95 475/0.5 1284 2.1 18.7 300 1025 4/0 120 608/0.5 1284 2.1 20.0 340 1280 NB Wire instructions and diameters are nominal. Current ratings are based on a conductor operaing temperature of 85 o C and an ambient air temperature of 45 o C and are for a single panel wire in free air. HIGH TEMPERATURE CABLES For current ratings refer to IEE Regulations table 4D1 on pages 108 to 109. 85

C-Tri Super Flexible Tri-Rated Panel Wires HIGH TEMPERATURE CABLES Specifically designed with single core PVC tri-rated panel wire, increased flexibility certified to American UL styles10151, 1028, 1283 and1284 and Canadian CSA C22.2 type TEW. These cables are for use at alternating voltages not exceeding 600V to earth and direct voltages not exceeding 1000V to earth. UL/CSA approved. Product Features Suitable for all fixed wiring switchboard/control panel applications Significant reduction in wiring installation time due to flexibility and ease of handling Smaller and more compact panel construction feasible due to bending radius and flexibility Extra fine untinned copper wire ensures high flexibility Special 105 o C PVC insulation provides outstanding flexibility and mechanical strength Self extinguishing - does not sustain combustion All cables are metre-marked and product coded Special cables can be supplied on request Technical Information Conductor: Plain annealed copper Stranding: Class 6 to IEC 60228 Insulation: Flexible PVC Voltage Rating: 0.6/1kV Operating Temperature: Minimum: 0 o C Maximum: 105 o C Standards: BS 6231, UL 83, CSA C22.2, UL Flame test UL 1581/VW1 FT1 FT2 C-Tri Super Flexible Tri-Rated Panel Wires Number of conductors x cross section area 2 Code Construction approximate number wires Nom OD Minimum Bending Radius Approximate weight Maximum amps 1 x 10 CSE1010 318/0.2 6.8 23 115 75 1 x 16 CSE1016 504/0.2 9.2 30 187 100 1 x 25 CSE1025 770/0.2 10.6 35 278 136 1 x 35 CSE1035 1,083/0.2 11.6 40 376 167 1 x 50 CSE1050 1,558/0.2 14.4 49 533 204 1 x 70 CSE1070 2,204/0.2 16.5 55 714 259 1 x 95 CSE1095 29,830/0.2 18.7 61 952 321 1 x 120 CSE1120 3,810/0.2 20 67 1,187 362 1 x 150 CSE1150 4,773/0.2 24.5 74 1,482 418 1 x 185 CSE1185 5,881/0.2 26.7 81 1,795 480 1 x 240 CSE1240 7,630/0.2 31.5 90 2,282 593 1 x 300 CSE1300 4,196/0.2-101 2,850 680 1 x 400 CSE1400 5,620/0.2-116 3,783 - Current ratings are based on a conductor operating temperature rise of 350 o C in free air at an ambient temperature of 350 o C. Cables above 120 2 in size are UL certified only. 86

2491B/6701B Single Core Equipment Wire Cable Application Suitable for wiring of appliances, switchgear instrument panels, metering equipment etc where smoke and toxic fumes arising in a fire sitution may threaten life or equipment. Technical Information Conductor: IEC 60228 (formally BS6360) class 5 flexible Insulation: Crosslinked low smoke halogen free - Type EI5, oxygen index 30. Colours: Full range of BS7646C colours available to order Voltage Rating: 2491B (H05Z - K) 0.5 2 to 1.0 2-300/500V 6701B (H07Z - K) 1.5 2 to 10 2-450/750V Temperature Range: 0-90 o C Bending Radius: Minimum: 3 x overall diameter Standards: BS7211 H05Z-K H07Z-K Cenelec HD22.9 Approvals: BASEC certified Area 2 Wire construction insulation thickness Overall diameter Conductor resistance at 20 o C. Ω/km max Insulation resistance at 90 o C MΩ.km min Nominal weight 0.75 24/0.2 0.6 2.34 26.0 0.0110 13 1.0 32/0.2 0.6 2.52 19.5 0.0100 16 1.5 30/0.25 0.7 3.00 13.3 0.0100 21 2.5 50/0.25 0.8 3.25 7.98 0.0090 33 4 56/0.3 0.8 4.12 4.95 0.0070 47 6 84/0.3 0.8 4.90 3.30 0.0060 66 10 80/0.4 1.0 6.05 1.91 0.0056 111 HIGH TEMPERATURE CABLES All figures are nominal unless otherwise stated. 2491B/6701B Single Core Equipment Wire 87

Extra Flexible PVC Robotic Cable ROBOTICS & CRANE CABLES Cable Application Suitable for automated production processes where data transmission cables of high flexibility are required, also for use in drag chains and where the cable is exposed to fast and abrupt movements. Technical Information Conductor: Super fine stranded plain copper Insulation: PVC core insulation, textile wrapping Outer Sheath: Grey PVC, RAL7001 as per VDE 0207 Stranding: According to VDE0295, class 6, IEC 60228 Operating Voltage Rating: 300/500V Temperature Range: Flexing: -5 o C to +70 o C Static: -40 o C to +70 o C Bending Radius: 10 x Ø Number of cores and 2 per conductor Outer diameter in maximum Copper weight Approximate weight 2 x 0.14 3.5 2.7 20 3 x 0.14 3.7 4.2 26 4 x 0.14 4.0 5.6 31 5 x 0.14 4.3 7.0 35 7 x 0.14 4.9 9.8 50 10 x 0.14 6.4 14.0 63 14 x 0.14 6.5 19.6 77 18 x 0.14 7.2 25.2 91 25 x 0.14 8.6 35.0 125 2 x 0.25 4.1 4.8 27 3 x 0.25 4.3 7.5 33 4 x 0.25 4.7 10.0 40 5 x 0.25 5.1 12.5 51 7 x 0.25 6.4 17.5 64 10 x 0.25 7.7 25.0 84 14 x 0.25 7.8 35.0 108 18 x 0.25 8.8 45.0 130 25 x 0.25 10.8 62.5 178 2 x 0.34 4.5 6.8 30 3 x 0.34 4.8 10.2 43 4 x 0.34 5.2 13.6 57 5 x 0.34 6.2 17.0 65 7 x 0.34 7.1 23.8 85 10 x 0.34 8.8 34.0 117 14 x 0.34 8.9 47.6 151 18 x 0.34 10.0 61.2 182 25 x 0.34 12.3 85.0 250 88

Number of cores and 2 per conductor Outer diameter in maximum Approximate weight 2 x 0.5 5.8 40 3 G 0.5 6.2 48 4 G 0.5 6.8 58 5 G 0.5 7.3 67 7 G 0.5 8.5 88 12 G 0.5 10.0 136 18 G 0.5 12.0 195 25 G 0.5 14.9 274 30 G 0.5 14.9 312 34 G 0.5 16.3 359 50 G 0.5 19.2 515 61 G 0.5 21.0 624 2 X 0.75 6.2 49 3 G 0.75 6.7 60 4 G 0.75 7.3 73 5 G 0.75 7.9 86 7 G 0.75 9.4 117 12 G 0.75 11.2 181 16 G 0.75 12.6 234 18 G 0.75 13.3 259 25 G 0.75 15.9 363 26 G 0.75 15.9 374 30 G 0.75 16.5 416 2 x 1.0 6.6 58 3 G 1.0 7.1 72 4 G 1.0 7.8 88 5 G 1.0 8.5 104 7 G 1.0 10.1 142 12 G 1.0 12.0 221 14 G 1.0 12.9 258 16 G 1.0 13.6 287 18 G 1.0 14.5 324 25 G 1.0 17.8 445 26 G 1.0 17.8 459 34 G 1.0 19.6 595 41 G 1.0 21.2 712 50 G 1.0 22.9 854 54 G 1.0 26.2 1,097 2 x 1.5 7.3 74 Number of cores and 2 per conductor Outer diameter in maximum Approximate weight 3 G 1.5 7.9 93 4 G 1.5 8.6 114 5 G 1.5 9.6 139 7 G 1.5 11.5 189 12 G 1.5 13.5 295 16 G 1.5 15.2 381 18 G 1.5 16.3 429 25 G 1.5 20.0 597 26 G 1.5 20.0 615 34 G 1.5 21.7 783 41 G 1.5 23.6 936 42 G 1.5 23.6 954 50 G 1.5 25.6 1134 52 G 1.5 25.6 1170 61 G 1.5 28.4 1372 3 G 2.5 9.5 145 4 G 2.5 10.5 179 5 G 2.5 11.8 218 7 G 2.5 14.2 303 12 G 2.5 16.7 473 14 G 2.5 17.9 548 3 G 4.0 11.2 214 4 G 4.0 12.3 266 5 G 4.0 13.7 325 4 G 6.0 14.5 396 5 G 6.0 16.2 484 4 G 10.0 18.3 644 5 G 10.0 20.3 785 4 G 16.0 21.2 922 5 G 16.0 23.7 1133 34 G 1.5 21.7 783 41 G 1.5 23.6 936 42 G 1.5 23.6 954 50 G 1.5 25.6 1,134 52 G 1.5 25.6 1,170 61 G 1.5 28.4 1,372 3 G 2.5 9.5 145 4 G 2.5 10.5 179 5 G 2.5 11.8 218 ROBOTICS & CRANE CABLES 89

Extra Flexible PVC Robotic Cable ROBOTICS & CRANE CABLES Number of cores and 2 per conductor Outer diameter in maximum Approximate weight 7 G 2.5 14.2 303 12 G 2.5 16.7 473 12 G 2.5 16.7 473 14 G 2.5 17.9 548 3 G 4.0 11.2 214 4 G 4.0 12.3 266 5 G 4.0 13.7 325 Number of cores and 2 per conductor Outer diameter in maximum Approximate weight 4 G 6.0 14.5 396 5 G 6.0 16.2 484 4 G 10.0 18.3 644 5 G 10.0 20.3 785 4 G 16.0 21.2 922 5 G 16.0 23.7 1,133 90

Extra Flexible Screened Robotic Cable Cable Application Suitable for automated production processes where data transmission cables of high flexibility are required, also for use in drag chains and where the cable is exposed to fast and abrupt movements. The overall screen grants a protection against electro-magnetic interferences. The EF CY is extra flexible class 6 stranding with pvc outer sheath particularly suitable for Robotics applications. Technical Information Conductors: Super fine stranded plain copper Insulation: PVC core insulation, textile wrapping Bedding: PVC inner sheath Screening: Overall tinned copper wire brand Outer Sheath: Grey PVC, RAL7001 Stranding: According to VDE 0295, class 6, IEC 60228 Operating Voltage Rating: 300/500V Temperature Range: -5 o C to +70 o C Bending Radius: 10 x Ø ROBOTICS & CRANE CABLES Number of cores and 2 per conductor Outer diameter in maximum Approximate weight 26 G 1.0 20.2 625 34 G 1.0 22.1 787 41 G 1.0 23.8 918 50 G 1.0 26.1 1,120 65 G 1.0 29.2 1,398 2 x 1.5 8.9 117 3 G 1.5 9.5 139 4 G 1.5 10.4 169 5 G 1.5 11.5 201 7 G 1.5 13.3 262 12 G 1.5 15.8 404 16 G 1.5 17.5 503 18 G 1.5 18.5 560 25 G 1.5 22.5 793 26 G 1.5 22.5 811 34 G 1.5 24.5 1,005 42 G 1.5 26.8 1,210 50 G 1.5 29.0 1,439 61 G 1.5 31.8 1,707 3 G 2.5 11.4 207 4 G 2.5 12.4 247 5 G 2.5 13.8 307 7 G 2.5 16.5 418 3 G 4.0 13.0 285 Number of cores and 2 per conductor Outer diameter in maximum Approximate weight 26 G 1.0 20.2 625 34 G 1.0 22.1 787 41 G 1.0 23.8 918 50 G 1.0 26.1 1,120 65 G 1.0 29.2 1,398 2 x 1.5 8.9 117 3 G 1.5 9.5 139 4 G 1.5 10.4 169 5 G 1.5 11.5 201 7 G 1.5 13.3 262 12 G 1.5 15.8 404 16 G 1.5 17.5 503 18 G 1.5 18.5 560 25 G 1.5 22.5 793 26 G 1.5 22.5 811 34 G 1.5 24.5 1,005 42 G 1.5 26.8 1,210 50 G 1.5 29.0 1,439 61 G 1.5 31.8 1,707 3 G 2.5 11.4 207 4 G 2.5 12.4 247 5 G 2.5 13.8 307 7 G 2.5 16.5 418 3 G 4.0 13.0 285 91

PUR Control Cable ROBOTICS & CRANE CABLES Cable Application Designed for use in heavy duty industrial applications where flexibility and heavy wear and tear are required. The PUR sheath makes this cable ideal for use in machine tool, plant manufacturing and power circuits because of it s extreme durability. Technical Information Conductor: Bare, flexible stranded copper Stranding: According to VDE 0295 class 5, IEC 60228 Insulation: Black PVC, number coded, Gly earth Outer Sheath: PUR Grey, RAL 7001, microbe and hydrolysis resistant, adhesion free, flame retardant Voltage: Working: 300/500V Test: 2000V Temperature Range: Flexing: -5 o C to 70 o C Static: -4 o C to +70 o C Bending Radius: 12.5 x Ø Number of cores and 2 per conductor Approx. outside diameter in ca. Copper weight Approx. weight 2 x 0.5 5.9 10 39 3 G 0.5 6.2 14 46 4 G 0.5 6.9 19 56 5 G 0.5 7.4 24 65 7 G 0.5 9.1 34 92 12 G 0.5 11.3 58 149 18 G 0.5 13.2 86 207 25 G 0.5 15.0 120 274 34 G 0.5 18.7 163 392 41 G 0.5 20.0 197 458 2 X 0.75 6.4 14 48 3 G 0.75 6.8 22 58 4 G 0.75 7.4 29 67 5 G 0.75 8.6 36 88 7 G 0.75 10.0 50 119 12 G 0.75 12.4 86 193 18 G 0.75 14.4 130 269 25 G 0.75 17.2 180 378 34 G 0.75 20.4 245 508 41 G 0.75 22.0 295 598 2 x 1.0 6.8 19 57 3 G 1.0 7.2 29 69 4 G 1.0 8.2 38 90 5 G 1.0 9.0 48 107 Number of cores and 2 per conductor Approx. outside diameter in ca. Copper weight Approx. weight 7 G 1.0 11.1 67 151 12 G 1.0 13.2 115 233 18 G 1.0 15.4 173 328 25 G 1.0 19.0 240 479 34 G 1.0 21.8 326 616 41 G 1.0 23.4 394 727 2 x 1.5 7.4 29 73 3 G 1.5 8.3 43 96 4 G 1.5 9.0 58 118 5 G 1.5 9.8 72 140 7 G 1.5 12.2 101 197 12 G 1.5 14.5 173 309 18 G 1.5 17.6 259 458 25 G 1.5 20.7 360 635 34 G 1.5 24.6 490 851 41 G 1.5 26.3 590 1003 3 G 2.5 9.7 72 142 4 G 2.5 11.0 96 184 5 G 2.5 12.1 120 220 7 G 2.5 14.2 168 294 12 G 2.5 17.8 288 489 7 G 4.0 20.0 268 532 7 G 6.0 21.5 403 694 92

PUR Screened Control Cable Cable Construction Control cable with high abrasion and tear resistant properties. Also resistant to mineral oils, especially to coolant emulsions and UV radiation. The copper braid screen protects against electromagnetic interferences and is, therefore, suitable as data transmission cable and connection cable. Technical Information Conductor: Bare flexible strandedcopper Stranding: According to VDE 0295 class 5, IEC 60228 Insulation: Black PVC, number coded, Gly earth Bedding: PVC Screen: Tinned copper wire braid screen, plain stranded copper Outer Sheath: PUR Grey, RAL 7001, microbe and hydrolysis resistant Voltage: Working: 300/500V Test: 2000V Temperature Range: Flexing: -5 o C to +70 o C Static: -5 o C to +70 o C Bending Radius: 12.5 x Ø Number of cores and 2 per conductor Approx. outside diameter in ca. Copper weight Approx. weight 2 x 0.5 8.0 39 92 3 G 0.5 8.3 44 100 4 G 0.5 8.8 52 120 5 G 0.5 9.7 61 139 7 G 0.5 11.2 75 175 12 G 0.5 13.7 131 276 18 G 0.5 15.7 168 376 25 G 0.5 18.5 212 485 2 x 0.75 8.4 45 104 3 G 0.75 8.7 52 119 4 G 0.75 9.5 67 142 5 G 0.75 10.2 75 165 7 G 0.75 11.9 96 210 12 G 0.75 14.5 160 331 18 G 0.75 16.9 217 468 25 G 0.75 20.3 283 596 2 x 1.0 8.7 49 117 3 G 1.0 9.3 60 132 4 G 1.0 9.9 78 163 5 G 1.0 10.8 88 187 Number of cores and 2 per conductor Approx. outside diameter in ca. Copper weight Approx. weight 7 G 1.0 12.8 115 255 12 G 1.0 15.4 201 419 15 G 1.0 17.7 267 546 25 G 1.0 21.5 351 738 34 G 1.0 23.8 498 972 2 x 1.5 9.5 68 159 3 G 1.5 9.9 83 180 4 G 1.5 10.8 102 217 5 G 1.5 11.6 119 265 7 G 1.5 14.2 186 392 12 G 1.5 16.8 264 554 18 G 1.5 20.0 379 782 25 G 1.5 23.5 534 1,059 34 G 1.5 26.7 695 1,359 41 G 1.5 28.9 803 1,579 3 G 2.5 11.4 121 264 4 G 2.5 12.6 145 307 5 G 2.5 14.0 205 413 7 G 2.5 16.4 259 533 12 G 2.5 21.0 407 795 ROBOTICS & CRANE CABLES 93

PUR Extra Flexible Cable ROBOTICS & CRANE CABLES Cable Application A highly flexible, unscreened PUR sheathed, robotics style cable. This cable is used in control circuits, measuring, power circuits, the automation industry and on assembly lines/production lines. Also suitable in drag chains where the cable is exposed to fast and abrupt movements. Technical Information Conductor: Super flexible plain copper Stranding: According to VDE 0295 class 6, IEC 60228 Insulation: PVC plus textile wrapping Cores: Number coded and Gly earth Outer Sheath: PUR Grey, RAL 7001, microbe and hydrolysis resistant, adhesion free, flame retardant Voltage: Working: 300/500V Test: 2000V Temperature Range: Flexing: -5 o C to +70 o C Static: -40 o C to +70 o C Bending Radius: 7.5 x Ø Number of cores and 2 per conductor Outer diameter in maximum Copper weight Approx. weight 2 x 0.5 5.8 10.0 36 3 G 0.5 6.2 15.0 44 4 G 0.5 6.8 19.2 53 5 G 0.5 7.3 24.0 62 7 G 0.5 8.5 34.0 82 12 G 0.5 10.0 58.0 129 18 G 0.5 12.0 86.4 185 2 x 1.75 6.2 15.0 44 3 G 0.75 6.7 22.0 55 4 G 0.75 7.3 29.0 67 5 G 0.75 7.9 37.0 80 7 G 0.75 9.4 51.0 109 12 G 0.75 11.2 87.0 172 16 G 0.75 12.6 116.0 223 18 G 0.75 13.3 130.0 247 25 G 0.75 15.9 181.0 346 26 G 0.75 15.9 188.0 357 2 x 1.0 6.6 20.0 52 3 G 1.0 7.1 29.0 66 4 G 1.0 7.8 39.0 82 5 G 1.0 8.5 48.0 97 7 G 1.0 10.1 67.0 117 12 G 1.0 12.0 115.0 211 16 G 1.0 13.6 153.0 275 18 G 1.0 14.5 173.0 310 Number of cores and 2 per conductor Outer diameter in maximum Copper weight Approx. weight 25 G 1.0 17.8 240.0 426 26 G 1.0 17.8 249.6 440 34 G 1.0 19.6 326.4 571 41 G 1.0 21.2 394.0 684 50 G 1.0 22.9 480.0 822 65 G 1.0 26.2 624.0 1058 2 x 1.5 7.3 29.0 68 3 G 1.5 7.9 43.2 86 4 G 1.5 8.6 58.0 106 5 G 1.5 9.6 72.0 131 7 G 1.5 11.5 101.0 178 12 G 1.5 13.5 173.0 281 16 G 1.5 15.2 230.0 365 18 G 1.5 16.3 269.0 411 25 G 1.5 20.0 360.0 571 26 G 1.5 20.0 374.4 589 34 G 1.5 21.7 489.6 753 42 G 1.5 23.6 629.0 919 50 G 1.5 25.6 720.0 1093 3 G 2.5 9.5 72.0 135 4 G 2.5 10.5 96.0 168 5 G 2.5 11.8 120.0 206 7 G 2.5 14.2 168.0 286 12 G 2.5 16.7 288.0 453 14 G 2.5 17.9 336.0 525 94

Number of cores and 2 per conductor Outer diameter in maximum Copper weight Approx. weight 3 G 4.0 11.2 120.0 201 4 G 4.0 12.3 160.0 252 5 G 4.0 13.7 200.0 309 1 G 6.0 6.7 60.0 84 4 G 6.0 14.7 230.0 377 5 G 6.0 16.2 288.0 461 Number of cores and 2 per conductor Outer diameter in maximum Copper weight Approx. weight 1 G 10.0 8.4 100.0 141 4 G 10.0 18.3 384.0 614 5 G 10.0 20.3 480.0 751 1 G 16.0 10.1 160.0 198 4 G 16.0 21.7 615.0 851 5 G 16.0 23.7 768.0 1,030 ROBOTICS & CRANE CABLES 95

PUR Extra Flexible Screened Cable ROBOTICS & CRANE CABLES Cable Application Designed for use in heavy duty industrial applications where flexibility and heavy wear and tear are required. For use in control circuits, measuring and also in power circuits, in the automation industry, in assembly lines and production lines etc. Suitable in drag chains where the cable is exposed to fast and abrupt movements. The copper braid screen protects against electro-magnetic interferences. Technical Information Conductor: Super fine, stranded, plain copper Stranding: According to VDE 0295 class 6, IEC 60228 Insulation: PVC insulated Cores: Number coded and gly earth Bedding: PVC Screen: Tinned copper wire braid Outer Sheath: PUR grey, RAL7001, microbe and hydrolysis-resistant, adhesion free, flame retardant Voltage: Working: 300/500V Test: 2000V Temperature Range: Flexing: -10 o C to +70 o C Static: -40 o C to +70 o C Bending Radius: 7.5 x Ø Number of cores and 2 per conductor Outer diameter in maximum Copper weight Approx. weight 2 x 0.5 6.9 33 70 3 G 0.5 7.3 39 80 4 G 0.5 7.9 46 94 5 G 0.5 8.4 54 106 7 G 0.5 9.8 70 138 12 G 0.5 11.3 100 194 18 G 0.5 13.4 153 277 2 x 0.75 7.3 39 81 3 G 0.75 7.8 48 95 4 G 0.75 8.4 59 111 5 G 0.75 9.0 69 128 7 G 0.75 10.7 90 171 12 G 0.75 12.4 129 244 16 G 0.75 14.2 186 328 18 G 0.75 14.9 205 356 25 G 0.75 18.0 271 479 2 x 1.0 7.7 46 93 3 G 1.0 8.2 57 109 4 G 1.0 8.9 70 129 5 G 1.0 9.8 81 154 7 G 1.0 11.4 110 200 12 G 1.0 13.4 182 304 Number of cores and 2 per conductor Outer diameter in maximum Copper weight Approx. weight 16 G 1.0 15.2 230 387 18 G 1.0 16.1 254 429 25 G 1.0 19.5 365 593 2 x 1.5 8.4 58 112 3 G 1.5 9.0 75 133 4 G 1.5 9.9 91 163 5 G 1.5 10.9 112 193 7 G 1.5 12.7 145 252 12 G 1.5 15.1 247 391 16 G 1.5 16.8 314 487 18 G 1.5 17.8 348 542 25 G 1.5 21.9 498 767 3 G 2.5 10.8 119 199 4 G 2.5 11.8 161 238 5 G 2.5 13.2 194 297 7 G 2.5 15.8 262 403 12 G 2.5 18.2 410 589 14 G 2.5 19.8 490 702 3 G 4.0 12.4 180 275 4 G 4.0 13.7 238 349 5 G 4.0 15.3 280 423 4 G 6.0 16.1 318 499 96

Number of cores and 2 per conductor Outer diameter in maximum Copper weight Approx. weight 5 G 6.0 17.7 410 596 4 G 10.0 20.2 521 842 5 G 10.0 22.2 714 995 Number of cores and 2 per conductor Outer diameter in maximum Copper weight Approx. weight 4 G 16.0 23.2 780 1,173 5 G 16.0 26.1 1050 1,460 ROBOTICS & CRANE CABLES 97

PVC Flatform Cable (H07VVH6-F) ROBOTICS & CRANE CABLES Cable Application Widely used on festoon systems supplying power and control to all types of moving machinery. Suitable in dry, wet and moist rooms and are used in conveyor and hoisting equipment etc, and as feed cable for mobile machine components. These cables have significant smaller bending radius compared to round cables. Technical Information Conductor: Flexible plain copper Stranding: According to VDE 0295, class 5, IEC 60228 Insulation: PVC Core Marking: up to 5 cores colour coded in accordance to VDE 0293; 7 cores and more are number coded with a green/yellow earth Outer Sheath: Black PVC Voltage Rating: 1 2-300/500V 1.5 2 up to 95 2-300/500V Temperature Range: Flexing: -15 o C to +70 o C Static: -30 o C to +70 o C Bending Radius: 10 x Ø Cores Cross section 2 Outer diameter Current rating at 30 o C (amps) Weight 12 1 35 x 4.3-39.2 16 1 46 x 4.3-52.1 20 1 57 x 4.3-64.2 24 1 68 x 4.3-77.2 4 1.5 14.5 x 5.2 19 13 5 1.5 17.5 x 5.2 19 16 7 1.5 25.3 x 5.2 19 23 8 1.5 25.3 x 5.2 19 26 10 1.5 27.3 x 5.2 19 32 12 1.5 40.8 x 5.2 19 38.5 18 1.5 61.8 x 5.2 19 66.5 24 1.5 83 x 5.2 19 82 4 2.5 17.5 x 5.9 25 19 5 2.5 21.1 x 5.9 25 23.5 7 2.5 31.1 x 5.9 25 34 Cores Cross section 2 Outer diameter Current rating at 30 o C (amps) Weight 8 2.5 33.1 x 5.9 25 37 10 2.5 42.6 x 5.9 25 51.5 12 2.5 49.1 x 5.9 25 56 24 2.5 102 x 5.9 25 122 4 4 20 x 6.9 34 27 5 4 26 x 6.9 34 28 7 4 35.3 x 6.9 34 48 4 10 27.6 x 9.3 60 58 5 10 37.5 x 11 60 112 4 16 43.5 x 11.2 80 118 4 25 41.2 x 13 101 134 4 35 49.6 x 14.5 126 180 4 50 58.4 x 17.5 153 252 4 70 63 x 20 196 367 4 95 73 x 21 238 453 PVC Flatform Cable (H07VVH6-F) 98

Neoprene Flatform Cable (NGFLGOEU-J) Cable Application Neoprene sheathed flat cables are designed to be used as electrical supply to moving machine components. This cable is weatherproof and thus suitable for use under adverse ambient conditions, e.g. for outdoor installation in shipyards, conveying equipment, on cranes and hoisting gear. These cables are extremely flexible and are typically used in applications with high mechanical stress and frequent bending in one plane. Technical Information Conductors: Flexible, plain copper Stranding: 25 2 and below according to VDE 0295 class 6, IEC 60228 35 2 and above according to VDE 0295 class 5, IEC 60228 Insulation: EPR rubber compound Sheath: Black neoprene Core Marking: Up to 5 cores colour coded in accordance to VDE 0293 7 cores and more are number coded with a green/yellow earth Voltage Rating: 300/500V Temperature Range: Flexing: -25 o C to +70 o C Static: -40 o C to +80 o C Bending Radius: 10 x Ø ROBOTICS & CRANE CABLES Cores Cross section 2 Outer diameter Current rating at 30 o C (amps) Weight 4 1.5 163. x 5.5 22 16.7 5 1.5 21 x 5.5 22 21.6 7 1.5 27.1 x 5.5 22 28.7 8 1.5 30.2 x 5.5 22 32.3 10 1.5 38.5 x 6.1 22 44.7 12 1.5 44.7 x 6.1 22 52.4 4 2.5 19.7 x 6.8 30 25.6 5 2.5 25 x 6.8 30 32.8 7 2.5 32.6 x 6.8 30 43.9 8 2.5 36.4 x 6.8 30 49.5 10 2.5 47 x 7.7 30 56.5 12 2.5 54.6 x 7.4 30 79.9 24 2.5 71 x 14.5 30 161.4 4 4 24.6 x 8.7 40 39.5 5 4 31.2 x 8.7 40 52.9 7 4 40.8 x 8.4 40 68.1 Cores Cross section 2 Outer diameter Current rating at 30 o C (amps) Weight 4 6 27.2 x 9 52 50.1 5 6 34.6 x 9 52 65.2 7 6 45.4 x 9 52 86.6 4 10 32.8 x 10.5 71 75 5 10 44 x 11.8 71 100 4 16 38.1 x 12.2 96 108.3 5 16 50 x 13.6 96 145 4 25 44.5 x 13.8 127 152.2 5 25 60 x 16.3 127 220 7 25 77.7 x 15 127 284.5 4 35 51 x 15.8 157 206.5 7 35 87.5 16.4 157 377 4 50 59.9 x 18.4 190 289.6 4 70 68 x 20.8 242 388.7 4 95 77.3 x 23.5 293 511.7 4 120 89.5 x 28.2 339 680.9 Neoprene Flatform Cable (NGFLG0EU - J 99

Neoprene Flatform Screened Cable ROBOTICS & CRANE CABLES Cable Application Neoprene sheathed flat cables are designed to be used as electrical supply to moving machine components. This cable is weatherproof and thus suitable for use under adverse ambient conditions, e.g. for outdoor installation in shipyards, conveying equipment, on cranes and hoisting gear. These cables are extremely flexible and are typically used in applications with high mechanical stress and frequent bending in one plane. The copper screening of the individual cores provides transmission of data and signals without other electrical interference (EMC). It is suitable in low temperatures. Technical Information Conductor: Flexible, plain copper Stranding: According to VDE 0295, class 5 or 6, IEC 60228 Insulation: Rubber Core Marking: up to 5 cores colour coded in accordance to VDE 0293 7 cores and more are number coded with a green/yellow earth Screening: Copper wire braid around each core Outer Sheath: Black neoprene Voltage: Working: 300/500V Test: 2000V Temperature Range: Flexible: -25 o C to +80 o C Static: -40 o C to +80 o C Bending Radius: 10 x Ø Cores Cross section 2 Outer diameter Current rating at 30 o C (amps) Weight 4 x 1.5 22.6 x 7.9 22 36.1 8 x 1.5 41.6 x 7.9 22 64.7 12 x 1.5 60.6 x 7.9 22 95.7 4 x 2.5 25 x 8.5 30 41.7 6 x 2.5 34.8 x 8.5 30 59.9 12 x 2.5 68.2 x 8.9 30 125 4 x 4 28.6 x 9.4 40 59 4 x 10 36.9 x 12.2 71 95 4 x 16 43.6 x 13.9 96 151.6 This cable is also available in PVC. 100

Submersible Pump TML Cable Flat Cable Application Special cable for the permanent use in process water type A - drinking water type B. Adapted to DIN VDE 0250 and DIN VDE 0282. As connection cable for submersible electric motors (pumps) for the permanent use in process and drinking water up to a temperature of 70 o C. Excellent insulation properties in water Very low water absorption Preservation of the mechanical strength Technical Information Conductor: Bare copper stranded class 5 to VDE0295, IEC 60228 Characteristics at 20 o C Insulation: EPR colour coded to VDE0293 Outer Sheath: EPR - colour blue Test Voltage 50Hz, 5 min: 2500V Rated Voltage: 450/750V ROBOTICS & CRANE CABLES Temperature Range Maximum admissible conductor Temperature in Operation: Short Circuit Temperature: Fixed: In Motion: Tensile stress: 90 o C 250 o C -40 o C up to +80 o C -25 o C up to +80 o C Maximum 15 N each 2 conductor cross section. No. of cores x cross Copper Content Outer Dimensions approx x Net weight approx 3 x 1.5 43.0 13. x 7 125 3 x 2.5 72.0 16 x 8 185 3 x 4 115.0 19 x 9 290 3 x 6 173.0 23 x 10 400 3 x 10 288.0 28 x 12 620 3 x 16 461.0 31 x 14 900 3 x 25 720.0 37 x 17 1150 3 x 35 1008.0 38 x 17 1550 3 x 50 1440.0 45 x 20 2200 3 x 70 2016.0 52 x 22 2900 No. of cores x cross Copper Content Outer Dimensions approx x Net weight approx 3 x 95 2736.0 58 x 25 3800 4 x 1.5 58.0 17 x 7 160 4 x 2.5 96.0 20 x 8 250 4 x 4 154.0 24 x 9 340 4 x 6 230.0 26 x 10 450 4 x 10 384.0 31 x 11 850 4 x 16 614.0 36 x 13 1200 4 x 25 960.0 45 x 15 1600 4 x 35 1344.0 48 x 17 2100 4 x 50 1920.0 59 x 20 2900 101

Submersible Pump TML Cable Round ROBOTICS & CRANE CABLES Cable Application Special cable for the permanent use in process water type A - drinking water type B. Adapted to DIN VDE 0250 and DIN VDE 0282. As connection cable for submersible electric motors (pumps) for the permanent use in process and drinking water up to a temperature of 70 o C. In addition DIN VDE 0298 T. 300 has to be respected. Excellent insulation properties in water Very low water absorption Preservation of the mechanical strength Technical Information Conductor: Insulation: Outer Sheath: Test Voltage 50Hz, 5 min: Rated Voltage: Temperature Range Maximum admissible conductor Temperature in Operation: Short Circuit Temperature: Fixed: In Motion: Tensile stress: Bare copper stranded class 5 to VDE0295 EPR colour coded to VDE0293 EPR - colour blue 2500V 450-750V 90 o C 250 o C -40 o C up to +80 o C -25 o C up to +80 o C Maximum 15 N each 2 conductor cross section No. of cores x cross Copper Content Outer Diameter Min. value Max. value Net weight 1 x 1.5 14.4 5.8 7.2 54 1 x 2.5 24.0 6.4 8.0 76 1 x 4 38.0 7.4 9.0 105 1 x 6 58.0 8.0 11.0 135 1 x 10 96.0 9.8 12.5 200 1 x 16 154.0 11.0 14.5 290 1 x 25 240.0 12.5 16.5 410 1 x 35 336.0 14.0 18.5 560 1 x 50 480.0 16.5 21.0 740 1 x 70 672.0 18.5 23.5 1,000 1 x 95 912.0 21.0 26.0 1,300 1 x 120 1152.0 23.5 28.5 1,650 1 x 150 1440.0 26.0 31.5 2,000 1 x 185 1776.0 27.5 34.5 2,500 1 x 240 2304.0 30.5 38.0 3,100 1 x 300 2880.0 33.5 41.5 3,700 No. of cores x cross Copper Content Outer Diameter Min. value Max. value Net weight 2 x 1.5 29.0 9.0 11.5 130 2 x 2.5 48.0 10.5 13.5 190 2 x 4 77.0 12.0 15.0 260 2 x 6 115.0 13.5 18.5 350 2 x 10 192.0 18.5 24.0 550 2 x 16 307.0 21.0 27.5 900 2 x 25 480.0 25.0 31.5 1300 3 x 1.5 43.0 9.6 12.5 150 3 x 2.5 72.0 11.5 14.5 220 3 x 4 115.0 13.0 16.0 340 3 x 6 173.0 14.5 20.0 480 3 x 10 288.0 20.0 25.5 750 3 x 16 461.0 22.5 29.5 1,100 3 x 25 720.0 26.5 34.0 1,450 3 x 35 1008.0 29.5 38.0 2,100 3 x 50 1440.0 34.5 44.0 2,800 102

No. of cores x cross Copper Content Outer Diameter Min. value Max. value Net weight 3 x 70 2016.0 39.0 49.5 3,800 3 x 95 2736.0 44.0 54.6 4,600 3 x 120 3456.0 47.5 59.0 5,400 4 x 1.5 58.0 10.5 13.5 190 4 x 2.5 96.0 12.5 15.5 280 4 x 4 154.0 14.5 18.0 390 4 x 6 230.0 16.5 22.0 520 4 x 10 384.0 22.5 24.5 950 4 x 16 614.0 26.5 28.5 1,400 4 x 25 960.0 32.0 34.0 1,950 4 x 35 1344.0 33.0 42.5 2,700 No. of cores x cross Copper Content Outer Diameter Min. value Max. value Net weight 4 x 50 1920.0 38.0 48.5 3,600 4 x 70 2688.0 43.0 54.5 4,900 4 x 95 3648.0 50.0 60.5 6,200 4 x 120 4608.0 53.0 65.5 7,200 5 x 1.5 72.0 11.5 15.0 230 5 x 2.5 120.0 13.5 17.0 340 5 x 4 192.0 16.0 19.5 470 5 x 6 288.0 18.0 24.5 640 5 x 10 480.0 24.0 30.5 1,150 5 x 16 768.0 27.0 35.5 1,700 ROBOTICS & CRANE CABLES 103

CSE Socacable (number coded) ENTERTAINMENT INDUSTRY CABLES Cable Application This cable has been created for public events for example concerts, theatre productions, light and sound events, external performances etc for the protection of the sound and light equipment. CSE Cables Socapex compatible cable has extreme flexibility and is extremely durable. Technical Information Conductor: Fine strands of copper wire Earth Conductor: Green/yellow in inner layer Core Insulation: PVC number coded Outer Sheath: Soft matt black PVC, RAL 9005 Stranding: According to VDE 0295 class 5, IEC 60228 Voltage: Working: 500V Test: 2000V Temperature Range Flexible: Operating: -5 o C to + 70 o C Static: -30 o C to + 80 o C Bending Radius: 15 x Ø Flame Retardant: According to VDE0482 part 331-1-2/IEC60332-1-2 Core and size 2 Nominal OD Weight 18c x 1.5 16 +/- 0.40 460/km 18c x 2.5 19.4 +/- 0.40 760/km We provide a cutting service completely free of charge. A complete range of accessories are available to suit the CSE Socacable. Socapex Number Coded Cable 104

H07RN-F Cable (BS7919:2001) The H07RN-F is designed primarily as a trailing cable for use in the supply of energy for portable or mobile equipment. Heavy duty Harmonized cables are not only robust but also extremely flexible. PCP neoprene is also oil and flame retardant. Typical applications of the H07RN-F cable include transformers, pumps, welders, grinders, temporary lighting cable and feed cables to heavy mobile equipment. Technical Information Stranding: Insulation: Sheath: Voltage: Temperature Range: Ambient Temperature: Operating Temperature: 60 C Minimum Bending Radius: Conductor Identification Single Core: Two Core: Three Core: Four Core: Five Core: Class 5 - fine copper wire strands manufactured to IEC 60228 (previously BS6360) EPR (Ethylene Propylene Rubber) Black neoprene (PCP) outer sheath to BS7919:2001 Working: 450/750V Test: 3000V -25 C to +85 C 30 C 6 x Ø for cables not exceeding 25 Static: 8 x Ø for cables exceeding 25 flexing 15 x Ø Black Brown and blue Brown, blue and green/yellow Brown, black, grey and green/yellow Brown, blue, black, grey and green/yellow ENTERTAINMENT INDUSTRY CABLES Core and size 2 Nominal O/Dia Weight 1 x 16.0 12.0 260 1 x 25.0 14.0 369 1 x 35.0 15.9 500 1 x 50.0 18.3 689 1 x 70.0 20.7 918 1 x 95.0 23.4 1,202 1 x 120.0 25.8 1,489 1 x 150.0 28.3 1,824 1 x 185.0 31.0 2,202 1 x 240.0 34.5 2,847 1 x 300.0 37.7 3,495 2 x 1.5 9.4 116 2 x 2.5 11.0 164 2 x 4.0 12.8 232 2 x 6.0 14.2 297 2 x 10.0 20.4 573 2 x 16.0 23.0 774 2 x 25.0 27.4 1,110 2 x 35.0 30.8 1,474 Core and size 2 Nominal O/Dia Weight 3 x 1.5 10.3 141 3 x 2.5 11.8 200 3 x 4.0 13.7 285 3 x 6.0 15.2 371 3 x 10.0 21.9 712 3 x 16.0 24.7 971 3 x 25.0 29.4 1,394 3 x 35.0 32.8 1,850 4 x 1.5 11.2 174 4 x 2.5 12.6 249 4 x 4.0 15.1 361 4 x 6.0 16.9 480 4 x 10.0 24.0 890 4 x 16.0 27.0 1,225 4 x 25.0 32.6 1,792 4 x 35.0 36.5 2,380 4 x 50.0 42.0 3,635 4 x 70.0 49.0 4,830 4 x 95.0 55.0 6,320 HO7RN-F Cable 105

H07RN-F Cable ENTERTAINMENT INDUSTRY CABLES Core and Size 2 Nominal O/Dia Weight 5 x 1.5 12.3 218 5 x 2.5 14.5 309 5 x 4.0 16.9 450 5 x 6.0 18.8 595 5 x 10.0 26.5 1,100 5 x 16.0 30.0 1,528 5 x 25.0 36.0 2,200 5 x 35.0 40.0 2,925 7 x 1.5 14.6 295 7 x 2.5 16.6 410 Core and Size 2 Nominal O/Dia Weight 12 x 1.5 18.9 500 12 x 2.5 22.0 720 19 x 1.5 22.5 715 19 x 2.5 26.0 1030 24 x 1.5 25.0 900 24 x 2.5 29.0 1,350 27 x 1.5 29.0 1,100 27 x 2.5 33.0 1,521 37 x 1.5 29.8 1,300 37 x 2.5 36.0 1,900 For current ratings refer to IEE Regulations tables 4F1 A and B on pages 122 to 123. 106

SiHF Cable Cable Application Suitable where PVC insulated where PVC insulated cables become brittle due to high temperature variations. Silicone insulated single cores are coonly used in the metallurgical industry, steel works, hot rolling mills, coking plants, foundries etc. SiHFP cable can be used in dry, moist and wet rooms as well as outdoors at high and low temperatures, as a flexible connecting cable. The insulation consists of silicone rubber. It is resistant to vegetable and animal fat, many types of oil and diluted acids. No decomposition occurs when exposed to alcohol, alkaline solutions etc. The insulation is resistant to oxygen and ozone. Should the cable burn, a silicone dioxide layer will remain on the conductor to render it short circuit proof. Technical Information Conductor: Stranded tinned copper wire conductor Insulation: Silicone rubber Sheath: Silicone outer sheath, red - brown Stranding: According to VDE 0295 class 5, IEC 60228 Voltage: Working: 300/500V Test: 3000V Temperature Range: Flexing: -60 o C to + 180 o C Temporarily: to +200 o C Bending Radius: Flexing: 15 x Ø Static: 7.5 x Ø Cores and size 2 Nominal O/DIA Weight ca. 2 x 0.75 6.4 53 2 x 1.0 6.6 60 2 x 1.5 7.6 82 2 x 2.5 9.2 135 3 x 0.75 6.8 64 3 x 1.0 7.4 78 3 x 1.5 8 98 3 x 2.5 9.7 152 3 x 4.0 11.4 220 3 x 6.0 14.2 338 4 x 0.75 7.8 84 4 x 1.0 8 95 4 x 1.5 8.8 120 4 x 2.5 10.6 189 4 x 4.0 13.1 295 Cores and size 2 Nominal O/DIA Weight ca. 4 x 6.0 16.2 440 4 x 10.0 20 700 4 x 16.0 24.3 985 5 x 0.75 8.5 100 5 x 1.0 8.9 115 5 x 1.5 9.6 148 5 x 2.5 11.6 229 5 x 4.0 14.4 359 7 x 0.75 9.2 125 7 x 1.0 9.5 144 7 x 1.5 10.4 187 7 x 2.5 12.6 293 12 x 1.5 14 332 18 x 1.5 17.3 420 24 x 1.5 20 635 ENTERTAINMENT INDUSTRY CABLES Other sizes and colours available on request. For the current ratings refer to the IEE Regulations tables 4F2A and B to 4F3A and B on pages 124 to 128. SiHF Cable 107

TECHNICAL TABLES Ambient Temperature: 30 o C Conductor Operating Temperature: 70 o C Current-carrying Capacity (amperes): Table 4D1A Single-core 70 o C Thermoplastic Insulated Cables, Non-Armoured, with or without Sheath Reference Method F (in free air or on a perforated cable tray horizontal or vertical etc.) Reference Method C (clipped direct) Touching Spaced by one diameter Reference Method B (enclosed in conduit on a wall or in trunking etc.) Reference Method A (enclosed in conduit in thermally insulating wall etc.) Conductor crosssectional area 2 cables, single-phase a.c. or d.c. or 3 cables three-phase a.c. flat 3 cables, threephase a.c. trefoil 3 cables, threephase a.c. flat 2 cables, singlephase a.c. or d.c. flat 3 or 4 cables, threephase a.c. flat and touching or trefoil 2 cables, singlephase a.c. or d.c. flat and touching 3 or 4 cables, threephase a.c. 2 cables, singlephase a.c. or d.c. 3 or 4 cables, threephase a.c. Vertical Horizontal 2 cables, singlephase a.c. or d.c. 1 2 3 4 5 6 7 8 9 10 11 12 ( 2 ) (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) 1 11 10.5 13.5 12 15.5 14 - - - - - 1.5 14.5 13.5 17.5 15.5 20 18 - - - - - 2.5 20 18 24 21 27 25 - - - - - 4 26 24 32 28 37 33 - - - - - 6 34 31 41 36 47 43 - - - - - 10 46 42 57 50 65 59 - - - - - 16 61 59 76 68 87 79 - - - - - 25 80 73 101 89 114 104 131 114 110 146 130 35 99 89 125 110 141 129 162 143 137 181 162 50 119 108 151 134 182 167 196 174 167 219 197 70 151 136 192 171 234 214 251 225 216 281 254 95 182 164 232 207 284 261 304 275 264 341 311 108

Table 4D1A Single-core 70 o C Thermoplastic Insulated Cables, Non-Armoured, with or without Sheath Reference Method F (in free air or on a perforated cable tray horizontal or vertical etc.) Reference Method C (clipped direct) Touching Spaced by one diameter Reference Method B (enclosed in conduit on a wall or in trunking etc.) Reference Method A (enclosed in conduit in thermally insulating wall etc.) Conductor crosssectional area 2 cables, single-phase a.c. or d.c. or 3 cables three-phase a.c. flat 3 cables, threephase a.c. trefoil 3 cables, threephase a.c. flat 2 cables, singlephase a.c. or d.c. flat 3 or 4 cables, threephase a.c. flat and touching or trefoil 2 cables, singlephase a.c. or d.c. flat and touching 3 or 4 cables, threephase a.c. 2 cables, singlephase a.c. or d.c. 3 or 4 cables, threephase a.c. Vertical Horizontal 2 cables, singlephase a.c. or d.c. 1 2 3 4 5 6 7 8 9 10 11 12 ( 2 ) (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) 120 210 188 269 239 330 303 352 321 308 396 362 150 240 216 300 262 381 349 406 372 356 456 419 185 273 245 341 296 436 400 463 427 409 521 480 240 321 286 400 346 515 472 546 507 485 615 569 300 367 328 458 394 594 545 629 587 561 709 659 400 - - 546 467 694 634 754 689 656 852 795 500 - - 626 533 792 723 868 789 749 982 920 630 - - 720 611 904 826 1,005 905 855 1,138 1,070 800 - - - - 1,030 943 1,086 1,020 971 1,265 1,188 1000 - - - - 1,154 1,058 1,216 1,149 1,079 1,420 1,337 Note: For cables having flexible conductors, see section 2.4 of this Appendix for adjustment factors for current-carrying capacity and voltage drop. TECHNICAL TABLES 109

Table 4D2A TECHNICAL TABLES Multicore 70 o C Thermoplastic Insulated and Thermoplastic Sheathed Cables, Non-Armoured Current-carrying Capacity (amperes): Conductor crosssectional area Reference Method A (enclosed in conduit in thermally insulating wall etc.) 1 twocore cable* singlephase a.c. or d.c. 1 threecore cable* or 1 fourcore cable, threephase a.c. Reference Method B (enclosed in conduit on a wall or in trunking etc.) 1 twocore cable* singlephase a.c. or d.c. 1 threecore cable* or 1 fourcore cable, threephase a.c. Ambient Temperature: 30 o C Conductor Operating Temperature: 70 o C Reference Method C (clipped direct) 1 twocore cable* singlephase a.c. or d.c. 1 threecore cable* or 1 fourcore cable, threephase a.c. Reference Method E (free air or on a perforated cable tray etc, horizontal or vertical) 1 twocore cable* singlephase a.c. or d.c. 1 threecore cable* or 1 four-core cable, threephase a.c. 1 2 3 4 5 6 7 8 9 ( 2 ) (A) (A) (A) (A) (A) (A) (A) (A) 1 11 10 13 11.5 15 13.5 17 14.5 1.5 14 13 16.5 15 19.5 17.5 22 18.5 2.5 18.5 17.5 23 20 27 24 30 25 4 25 23 30 27 36 32 40 34 6 32 29 38 34 46 41 51 43 10 43 39 52 46 63 57 70 60 16 57 52 69 62 85 76 94 80 Note: * With or without protective conductor. 110

Table 4D2B Voltage Drop (per ampere per metre): Conductor cross-sectional area Two-core cable d.c. Conductor Operating Temperature: 70 o C Two-core cable single-phase a.c. Three- or four-core cable, three-phase a.c. 1 2 3 4 ( 2 ) (mv/a/m) (mv/a/m) (mv/a/m) 1 44 44 38 1.5 29 29 25 2.5 18 18 15 4 11 11 9.5 6 7.3 7.3 6.4 10 4.4 4.4 3.8 16 2.8 2.8 2.4 TECHNICAL TABLES 111

TECHNICAL TABLES Ambient Temperature: 30 o C Conductor Operating Temperature: 90 o C Current-carrying Capacity (amperes): Table 4E1A Single-Core 90 o C Thermosetting Insulated Cables, Non-Armoured, with or without Sheath Reference Method G (in free air) Reference Method F (in free air or on a perforated cable tray etc horizontal or vertical etc.) Reference Method C (clipped direct) Spaced by one cable diameter Reference Method B (enclosed in conduit on a wall or in trunking etc.) Reference Method A (enclosed in conduit in thermally insulating wall etc.) Conductor crosssectional area Touching Spaced by one cable diameter 2 cables, single-phase a.c. or d.c. or 3 cables three-phase a.c. flat 3 cables, threephase a.c. trefoil 3 cables, threephase a.c. flat 2 cables, singlephase a.c. or d.c. flat 3 or 4 cables, threephase a.c. flat and touching or trefoil 2 cables, singlephase a.c. or d.c. flat and touching 3 or 4 cables, threephase a.c. 2 cables, singlephase a.c. or d.c. 3 or 4 cables, threephase a.c. Vertical Horizontal 2 cables, singlephase a.c. or d.c. 1 2 3 4 5 6 7 8 9 10 11 12 ( 2 ) (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) 1 14 13 17 15 19 17.5 - - - - - 1.5 19 17 23 20 25 23 - - - - - 2.5 26 23 31 28 34 31 - - - - - 4 35 31 42 37 46 41 - - - - - 6 45 40 54 48 59 54 - - - - - 10 61 54 75 66 81 74 - - - - - 16 81 73 100 88 109 99 - - - - - 25 106 95 133 117 143 130 161 141 135 182 161 35 131 117 164 144 176 161 200 176 169 226 201 50 158 141 198 175 228 209 242 216 207 275 246 70 200 179 253 222 293 268 310 279 268 353 318 95 241 216 306 269 355 326 377 342 328 430 389 112

Table 4E1A Single-Core 90 o C Thermosetting Insulated Cables, Non-Armoured, with or without Sheath Ambient Temperature: 30 o C Conductor Operating Temperature: 90 o C Current-carrying Capacity (amperes): Reference Method G (in free air) Reference Method F (in free air or on a perforated cable tray etc horizontal or vertical etc.) Reference Method C (clipped direct) Spaced by one cable diameter Reference Method B (enclosed in conduit on a wall or in trunking etc.) Reference Method A (enclosed in conduit in thermally insulating wall etc.) Conductor crosssectional area Touching Spaced by one cable diameter 2 cables, single-phase a.c. or d.c. or 3 cables three-phase a.c. flat 3 cables, threephase a.c. trefoil 3 cables, threephase a.c. flat 2 cables, singlephase a.c. or d.c. flat 3 or 4 cables, threephase a.c. flat and touching or trefoil 2 cables, singlephase a.c. or d.c. flat and touching 3 or 4 cables, threephase a.c. 2 cables, singlephase a.c. or d.c. 3 or 4 cables, threephase a.c. Vertical Horizontal 2 cables, singlephase a.c. or d.c. 1 2 3 4 5 6 7 8 9 10 11 12 ( 2 ) (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) 120 278 249 354 312 413 379 437 400 383 500 454 150 318 285 393 342 476 4036 504 464 444 577 527 185 362 324 449 384 545 500 575 533 510 661 605 240 424 380 528 450 644 590 679 634 607 781 719 300 486 435 603 514 743 681 783 736 703 902 833 400 - - 683 584 868 793 940 868 823 1,085 1,008 500 - - 783 666 990 904 1,083 998 946 1,253 1,169 630 - - 900 764 1,130 1,033 1,254 1,151 1,088 1,454 1,362 800 - - - - 1,288 1,179 1,358 1,275 1,214 1,581 1,485 1,000 - - - - 1,443 1,323 1,520 1,436 1,349 1,775 1,671 TECHNICAL TABLES Notes: 1. Where it is intended to connect the cables in this table to equipment or accessories designed to operate at a temperature lower than the maximum operating temperature of the cable, the cables should be rated at the maximum operating temperature of the equipment or accessory (see Regulation 512.1.5). 2. Where it is intended to group a cable in this table with other cables, the cable should be rated at the lowest of the maximum operating temperatures of any of the cables in the group (see Regulation 512.1.5). 3. For cables having flexible conductors see section 2.4 of this appendix for adjustment factors for currentcarrying capacity and voltage drop. 113

Table 4E1B TECHNICAL TABLES Voltage Drop (per ampere per metre): Conductor Operating Temperature: 90 o C Single-Core 90 o C Thermosetting Insulated Cables, Non-Armoured, with or without Sheath 2 cables, single-phase a.c. 3 or 4 cables, three-phase a.c. Reference Methods C, F & G (clipped direct, on tray or in free air) Reference Methods A & B (enclosed in conduit or trunking) Reference Methods C & F (clipped direct, on tray or free air) Reference Method A & B (enclosed in conduit or trunking) 2 cables, d.c. Conductor crosssectional area Cables spaced*, flat Cables touching, flat Cables touching Cables spaced* Cables touching, trefoil 1 2 3 4 5 6 7 8 9 (mv/a/m) (mv/a/m) (mv/a/m) (mv/a/m) (mv/a/m) ( 2 ) (mv/ A/m) 1 46 46 46 46 40 40 40 40 1.5 31 31 31 31 27 27 27 27 2.5 19 19 19 19 16 16 16 16 4 12 12 12 12 10 10 10 10 6 7.9 7.9 7.9 7.9 6.8 6.8 6.8 6.8 10 4.7 4.7 4.7 4.7 4.0 4.0 4.0 4.0 16 2.9 2.9 2.9 2.9 2.5 2.5 2.5 2.5 r x z r x z r x z r x z r x z r x z r x z 25 1.85 1.85 0.31 1.90 1.85 0.190 1.85 1.85 0.28 1.85 1.60 0.27 1.65 1.60 1.165 1.60 1.60 0.190 1.60 1.60 0.27 1.65 35 1.35 1.35 0.29 1.35 1.35 0.180 1.35 1.35 0.27 1.35 1.15 0.25 1.15 1.15 0.155 1.15 1.15 0.180 1.15 1.15 0.26 1.20 50 0.99 1.00 0.29 1.05 0.99 0.180 1.00 0.99 0.27 1.00 0.87 0.25 0.90 0.86 0.155 0.87 0.86 0.180 0.87 0.86 0.26 0.89 70 0.68 0.70 0.28 0.75 0.68 0.175 0.71 0.68 0.26 0.73 0.60 0.24 0.65 0.59 0.150 0.61 0.59 0.175 0.62 0.59 0.25 0.65 95 0.49 0.51 0.27 0.58 0.49 0.170 0.52 0.49 0.26 0.56 0.44 0.23 0.50 0.43 0.145 0.45 0.43 0.170 0.46 0.43 0.25 0.49 120 0.39 0.41 0.26 0.48 0.39 0.165 0.43 0.39 0.25 0.47 0.35 0.23 0.42 0.34 0.140 0.37 0.34 0.165 0.38 0.34 0.24 0.42 150 0.32 0.33 0.26 0.43 0.32 0.165 0.36 0.32 0.25 0.41 0.29 0.23 0.37 0.28 0.140 0.31 0.28 0.165 0.32 0.28 0.24 0.37 114

Table 4E1B Single-Core 90 o C Thermosetting Insulated Cables, Non-Armoured, with or without Sheath Voltage Drop (per ampere per metre): Conductor Operating Temperature: 90 o C 2 cables, single-phase a.c. 3 or 4 cables, three-phase a.c. Reference Methods C, F & G (clipped direct, on tray or in free air) Reference Methods C & F (clipped direct, on tray or free air) Reference Method A & B (enclosed in conduit or trunking) 2 cables, d.c. Conductor crosssectional area Cables spaced*, flat Cables touching, flat Cables touching Cables spaced* Cables touching, trefoil Reference Methods A & B (enclosed in conduit or trunking) 1 2 3 4 5 6 7 8 9 (mv/a/m) (mv/a/m) (mv/a/m) (mv/a/m) (mv/a/m) ( 2 ) (mv/ A/m) r x z r x z r x z r x z r x z r x z r x z 185 0.25 0.27 0.26 0.37 0.26 0.165 0.30 0.25 0.25 0.36 0.23 0.23 0.32 0.22 0.140 0.26 0.22 0.165 0.28 0.22 0.24 0.33 240 0.190 0.21 0.26 0.33 0.20 0.160 0.25 0.195 0.25 0.31 0.185 0.22 0.29 0.170 0.140 0.22 0.170 0.165 0.24 0.170 0.24 0.29 300 0.155 0.175 0.25 0.31 0.160 0.160 0.22 0.155 0.25 0.29 0.150 0.22 0.27 0.140 0.140 0.195 0.135 0.160 0.21 0.135 0.24 0.27 400 0.120 0.140 0.25 0.29 0.130 0.155 0.20 0.125 0.24 0.27 0.125 0.22 0.25 0.110 0.135 0.175 0.110 0.160 0.195 0.110 0.24 0.26 500 0.093 0.120 0.25 0.28 0.105 0.155 0.185 0.098 0.24 0.26 0.100 0.22 0.24 0.090 0.135 0.160 0.088 0.160 0.180 0.085 0.24 0.25 630 0.072 0.100 0.25 0.27 0.086 0.155 0.175 0.078 0.24 0.25 0.088 0.21 0.23 0.074 0.135 0.150 0.071 0.160 0.170 0.068 0.23 0.24 800 0.056-0.072 0.150 0.170 0.064 0.24 0.25-0.062 0.130 0.145 0.059 0.155 0.165 0.055 0.23 0.24 1,000 0.045-0.063 0.150 0.165 0.054 0.24 0.24-0.055 0.130 0.140 0.050 0.155 0.165 0.047 0.23 0.24 Note: * Spacings larger than one cable diameter will result in a larger voltage drop. TECHNICAL TABLES 115

Table 4E2A TECHNICAL TABLES Multi-Core 90 o C Thermosetting Insulated Cables and thermoplastic Sheathed Cables, Non-Armoured Current-carrying Capacity (amperes): Conductor crosssectional area Reference Method A (enclosed in conduit in thermally insulating wall etc.) 1 twocore cable*, singlephase a.c. or d.c. 1 threeor fourcore cable*, threephase a.c. Reference Method B (enclosed in conduit on a wall or in trunking etc.) 1 twocore cable*, singlephase a.c. or d.c. 1 threeor fourcore cable*, threephase a.c. Ambient Temperature: 30 o C Conductor Operating Temperature: 900 o C Reference Method C (clipped direct) 1 twocore cable*, singlephase a.c. or d.c. 1 threeor fourcore cable*, threephase a.c. Reference Method E (free air or on a perforated cable tray etc horizontal or vertical) 1 twocore cable*, singlephase a.c. or d.c. 1 threeor fourcore cable*, threephase a.c. 1 2 3 4 5 6 7 8 9 ( 2 ) (A) (A) (A) (A) (A) (A) (A) (A) 1 14.5 13 17 15 19 14 21 18 1.5 18.5 16.5 22 19.5 24 22 26 23 2.5 25 22 30 26 33 30 36 32 4 33 30 40 35 45 40 49 42 6 42 38 51 44 58 52 63 54 10 57 51 69 60 80 71 86 75 16 76 68 91 80 107 96 115 100 25 99 89 119 105 138 119 149 127 35 121 109 146 128 171 147 185 158 50 145 130 175 154 209 179 225 192 70 183 164 221 194 269 229 289 246 95 220 197 265 233 328 278 352 298 120 253 227 305 268 382 322 410 346 150 290 259 334 300 441 371 473 399 185 329 295 384 340 506 424 542 456 240 386 346 459 398 599 500 641 538 300 442 396 532 455 693 576 741 621 400 - - 625 536 803 667 865 741 116 Notes: * With or without a protective conductor 1. Where it is intended to connect the cables in this table to equipment or accessories designed to operate at a temperature lower than the maximum operating temperature of the cable, the cables should be rated at the maximum operating temperature of the equipment or accessory (see Regulation 512.1.5). 2. Where it is intended to group a cable in this table with other cables, the cable should be rated at the lowest of the maximum operating temperatures of any of the cables in the group (see Regulation 512.1.5). 3. For cables having flexible conductors see section 2.4 of this appendix for adjustment factors for currentcarrying capacity and voltage drop.

Table 4E2B Voltage Drop (per ampere per metre): Conductor cross-sectional area Two-core cable d.c. Conductor Operating Temperature: 90 o C Two-core cable singlephase a.c. Three- or four-core cable, three-phase a.c. 1 2 3 4 ( 2 ) (mv/a/m) (mv/a/m) (mv/a/m) 1 46 46 40 1.5 31 31 27 2.5 19 19 16 4 12 12 10 6 7.9 7.9 6.8 10 4.7 4.7 4.0 16 2.9 2.9 2.5 TECHNICAL TABLES r x z r x z 25 1.85 1.85 0.160 1.90 1.60 0.140 1.65 35 1.35 1.35 0.155 1.35 1.15 0.135 1.15 50 0.98 0.99 0.155 1.00 0.86 0.135 0.87 70 0.67 0.67 0.150 0.69 0.59 0.130 0.60 95 0.49 0.50 0.150 0.52 0.43 0.130 0.45 120 0.39 0.40 0.145 0.42 0.34 0.130 0.37 150 0.31 0.32 0.145 0.35 0.28 0.125 0.30 185 0.25 0.26 0.145 0.29 0.22 0.125 0.26 240 0.195 0.200 0.140 0.24 0.175 0.125 0.21 300 0.155 0.160 0.140 0.21 0.140 0.120 0.185 400 0.120 0.130 0.140 0.190 0.115 0.120 0.165 117

TECHNICAL TABLES Ambient Temperature: 30 o C Conductor Operating Temperature: 90 o C Current-carrying Capacity (amperes): Table 4E3A Single-Core Armoured 90 o C Thermosetting Insulated Cables, Non-Magnetic Armour Reference Method F (in free air or on a perforated cable tray, horizontal or vertical) Reference Method C (clipped direct) Touching Touching Spaced by one cable diameter Conductor crosssectional area 3 or 4 cables, three-phase a.c. 2 cables, d.c. 2 cables, single-phase a.c. 3 cables, threephase a.c. or d.c. trefoil 3 cables, threephase a.c. or d.c. flat 2 cables, singlephase a.c. or d.c. flat 3 or 4 cables, threephase a.c. flat Vertical Horizontal Vertical Horizontal Vertical Horizontal 2 cables, singlephase a.c. or d.c. flat 1 2 3 4 5 6 7 8 9 10 11 12 ( 2 ) (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) (A) 50 237 220 253 232 222 284 270 282 266 288 266 70 303 277 322 293 285 356 349 357 337 358 331 95 367 333 389 352 346 446 426 436 412 425 393 120 425 383 449 405 402 519 497 504 477 485 449 150 488 437 516 462 463 600 575 566 539 549 510 185 557 496 587 524 529 688 660 643 614 618 574 240 656 579 689 612 625 815 782 749 714 715 666 300 755 662 792 700 720 943 906 842 805 810 755 Notes: 1. Where it is intended to connect the cables in this table to equipment or accessories designed to operate at a temperature lower than the maximum operating temperature of the cable, the cables should be rated at the maximum operating temperature of the equipment or accessory (see Regulation 512.1.5). 2. Where it is intended to group a cable in this table with other cables, the cable should be rated at the lowest of the maximum operating temperatures of any of the cables in the group (see Regulation 512.1.5). 400 853 717 899 767 815 1,137 1,094 929 889 848 797 500 962 791 1,016 851 918 1,314 1,266 1,032 989 923 871 630 1,082 861 1,146 935 1,027 1,528 1,474 1,139 1,092 992 940 800 1,170 904 1,246 987 1,119 1,809 1,744 1,204 1,155 1,042 978 1,000 1,261 961 1,345 1,055 1,214 2,100 2,026 1,289 1,238 1,110 1,041 118

Table 4E3B Voltage Drop (per ampere per metre): Conductor Operating Temperature: 90 o C Conductor crosssectional area 2 cables, d.c. Reference Methods C & F (clipped direct, on tray or free air) 2 cables, single-phase a.c. 3 or 4 cables, three-phase a.c. Touching Spaced* Trefoil and touching Flat and touching Flat and spaced* 1 2 3 4 5 6 7 ( 2 ) (mv/ A/m) (mv/a/m) (mv/a/m) (mv/a/m) (mv/a/m) (mv/a/m) r x z r x z r x z r x z r x z 50 0.98 0.99 0.21 1.00 0.98 0.29 1.00 0.86 0.180 0.78 0.84 0.25 0.88 0.84 0.33 0.90 70 0.67 0.68 0.200 0.71 0.69 0.29 0.75 0.59 0.170 0.62 0.60 0.25 0.65 0.62 0.32 0.70 95 0.49 0.51 0.195 0.55 0.53 0.28 0.60 0.44 0.170 0.47 0.46 0.24 0.52 0.49 0.31 0.58 120 0.39 0.41 0.190 0.45 0.43 0.27 0.51 0.35 0.165 0.39 0.38 0.24 0.44 0.41 0.30 0.51 150 0.31 0.33 0.185 0.38 0.36 0.27 0.45 0.29 0.160 0.33 0.31 0.23 0.39 0.34 0.29 0.45 185 0.25 0.27 0.185 0.33 0.30 0.26 0.40 0.23 0.160 0.28 0.26 0.23 0.34 0.29 0.29 0.41 240 0.195 0.21 0.180 0.28 0.24 0.26 0.35 0.180 0.155 0.24 0.21 0.22 0.30 0.24 0.28 0.37 300 0.155 0.170 0.175 0.25 0.195 0.25 0.32 0.145 0.150 0.21 0.170 0.22 0.28 0.20 0.27 0.34 400 0.115 0.145 0.170 0.22 0.180 0.24 0.30 0.125 0.150 0.195 0.160 0.21 0.27 0.20 0.27 0.33 500 0.093 0.125 0.170 0.21 0.165 0.24 0.29 0.105 0.145 0.180 0.145 0.20 0.25 0.190 0.24 0.31 630 0.073 0.105 0.165 0.195 0.150 0.23 0.27 0.092 0.145 0.170 0.135 0.195 0.24 0.175 0.23 0.29 800 0.056 0.090 0.160 0.190 0.145 0.23 0.27 0.086 0.140 0.165 0.130 0.180 0.23 0.175 0.195 0.26 1,000 0.045 0.092 0.155 0.180 0.140 0.21 0.25 0.080 0.135 0.155 0.125 0.170 0.21 0.165 0.180 0.24 Note: * Spacings larger than one cable diameter will result in a larger voltage drop. TECHNICAL TABLES 119

Table 4E4A TECHNICAL TABLES Multicore 90 o C Thermosetting Insulated Cables Current-carrying Capacity (amperes): Conductor crosssectional area Reference Method C (clipped direct) 1 twocore cable singlephase a.c. or d.c. 1 three-or 1 four-core cable, threephase a.c. Reference Method E (in free air or on a perforated cable tray etc, horizontal or vertical) 1 twocore cable singlephase a.c. or d.c. Air Ambient Temperature: 30 o C Ground Ambient Temperature: 20 o C Conductor Operating Temperature: 90 o C 1 three-or 1 fourcore cable, three-phase a.c. Reference Method D (direct in ground or in ducting in ground, in or around buildings) 1 two-core cable singlephase a.c. or d.c. 1 three-or 1 four-core cable, threephase a.c. 1 2 3 4 5 6 7 ( 2 ) (A) (A) (A) (A) (A) (A) 1.5 27 23 29 25 25 21 2.5 36 31 39 33 33 28 4 49 42 52 44 46 36 6 62 53 66 56 53 44 10 85 73 90 78 71 58 16 110 94 115 99 91 75 25 146 124 152 131 116 96 35 180 154 188 162 139 115 50 219 187 228 197 164 135 70 279 238 291 251 203 167 95 338 289 354 304 239 197 120 392 335 410 353 271 223 150 451 386 472 406 306 251 185 515 441 539 463 343 281 240 607 520 636 546 395 324 300 698 599 732 628 446 365 400 787 673 847 728 - - Notes: 1. Where it is intended to connect the cables in this table to equipment or accessories designed to operate at a temperature lower than the maximum operating temperature of the cable, the cables should be rated at the maximum operating temperature of the equipment or accessory (see Regulation 512.1.5). 2. Where it is intended to group a cable in this table with other cables, the cable should be rated at the lowest of the maximum operating temperatures of any of the cables in the group (see Regulation 512.1.5). 120

Table 4E4B Voltage Drop (per ampere per metre): Conductor cross-sectional area Two-core cable d.c. Two-core cable, single-phase a.c. Conductor Operating Temperature: 90 o C Three- or four-core cable, threephase a.c. 1 2 3 4 ( 2 ) (mv/a/m) (mv/a/m) (mv/a/m) 1.5 31 31 27 2.5 19 19 16 4 12 12 10 6 7.9 7.9 6.8 10 4.7 4.7 4.0 16 2.9 2.9 2.5 r x z r x z 25 1.85 1.85 0.160 1.90 1.60 0.140 1.65 35 1.35 1.35 0.155 1.35 1.15 0.135 1.15 50 0.98 0.99 0.155 1.00 0.86 0.135 0.87 70 0.67 0.67 0.150 0.69 0.59 0.130 0.60 95 0.49 0.50 0.150 0.52 0.43 0.130 0.45 TECHNICAL TABLES 120 0.39 0.40 0.145 0.42 0.34 0.130 0.37 150 0.31 0.32 0.145 0.35 0.28 0.125 0.30 185 0.25 0.26 0.145 0.29 0.22 0.125 0.26 240 0.195 0.20 0.140 0.24 0.175 0.125 0.21 300 0.155 0.16 0.140 0.21 0.140 0.120 0.185 400 0.120 0.13 0.140 0.190 0.115 0.120 0.165 121

Table 4F1A TECHNICAL TABLES 60 o C Thermosetting Insulated Flexible Cables with Sheath, Non-Armoured Current-carrying Capacity (amperes): Conductor cross-sectional area Single-phase a.c. or d.c. 1 two-core cable, with or without protective conductor Ambient Temperature: 30 o C Conductor Operating Temperature: 60 o C Three-phase a.c. 1 three-core, four-core or five-core Single-phase a.c. or d.c. 2 single-core cable 1 2 3 4 ( 2 ) (A) (A) (A) 4 30 26-6 39 34-10 51 47-16 73 63-25 97 83-35 - 102 140 50-124 175 70-158 216 95-192 258 Refer to Notes 1, 2 and 3 below Notes: 1. The current ratings tabulated are for cables in free air but may also be used for cables resting on a surface. If the cable is to be wound on a drum on load the ratings should be reduced in accordance with Note 2 below and for cables which may be covered, Note 3 below. 2. Flexible cables wound on reeling drums The current ratings of cables used on reeling drums are to be reduced by the following factors: a) Radial type drum b) Ventilated cylindrical type drum ventilated: 85% 1 layer of cable: 85% unventilated: 75% 2 layers of cable: 65% 3 layers of cable: 45% 4 layers of cable: 35% A radial type drum is one where spiral layers of cable are accoodated between closely spaced flanges; if fitted with solid flanges the ratings given above should be reduced and the drum is described as non-ventilated. If the flanges have suitable apertures the drum is described as ventilated. A ventilated cylindrical cable drum is one where layers of cable are accoodated between widely spaced flanges and the drum and end flanges have suitable ventilating apertures. 3. Where cable may be covered over or coiled up whilst on load, or the air movement over the cable restricted, the current rating should be reduced. It is not possible to specify the amount of reduction but the table of rating factors for reeling drums can be used as a guide. 122

Table 4F1B 60 o C Thermosetting Insulated Flexible Cables Voltage Drop (per ampere per metre): Conductor crosssectional area Two-core cable d.c. Two-core cable, single-phase a.c. 1 three-core, four-core or five-core cable, three-phase a.c. Conductor Operating Temperature: 60 o C 2 single-core cables, touching d.c. Single-phase a.c.* 1 2 3 4 5 6 ( 2 ) (mv/a/m) (mv/a/m) (mv/a/m) (mv/a/m) (mv/a/m) 4 12 12 10 - - 6 7.8 7.8 6.7 - - 10 4.6 4.6 4.0 - - 16 2.9 2.9 2.5 - - r x z r x z r x z 25 1.80 1.80 0.175 1.85 1.55 0.150 1.55 - - - - 35 - - - - 1.10 0.150 1.15 1.31 1.31 0.21 1.32 50 - - - - 0.83 0.145 0.84 0.91 0.91 0.21 0.93 70 - - - - 0.57 0.140 0.58 0.64 0.64 0.20 0.67 95 - - - - 0.42 0.135 0.44 0.49 0.49 0.195 0.53 TECHNICAL TABLES Note: * A larger voltage drop will result if the cables are spaced. 123

Table 4F2A TECHNICAL TABLES 90 o C and 180 o C Thermosetting Insulated Flexible Cables with Sheath, Non-Armoured (Copper Conductors) Current-carrying Capacity (amperes): Conductor cross-sectional area Single-phase a.c. or d.c. 1 two-core cable, with or without protective conductor Ambient Temperature: 30 o C Conductor Operating Temperature: 90 o C Three-phase a.c. 1 three-core, four-core or five-core Single-phase a.c. or d.c. 2 single-core cables, touching 1 2 3 4 ( 2 ) (A) (A) (A) 4 42 37-6 55 49-10 76 66-16 103 89-25 136 119-35 - 146 200 50-146 200 50-177 250 70-225 310 95-273 369 120-316 432 150-363 497 185-414 567 240-487 673 300-560 773 400 - - 924 500 - - 1,062 630 - - 1,242 Rating Factor for Ambient Temperature 90 o C Thermoplastic or Thermosetting Insulated Cords: Ambient Temperature: 35 o C 40 o C 45 o C 50 o C 55 o C 60 o C 65 o C 70 o C 75 o C 80 o C 85 o C Correction Factor: 0.95 0.91 0.86 0.82 0.76 0.70 0.64 0.57 0.50 0.40 0.28 180 o C Thermosetting Insulated Cords: Ambient Temperature: 35 o C to 90 o C 95 o C 100 o C 105 o C 110 o C 150 o C 120 o C 125 o C 130 o C 135 o C Correction Factor: 1.0 0.96 0.91 0.86 0.81 0.76 0.70 0.64 0.57 0.50 Ambient Temperature: 140 o C 145 o C Correction Factor: 0.40 0.28 124

Notes: 1. The current ratings tabulated are for cables in free air but may also be used for cables resting on a surface. If the cable is to be wound on a drum on load the ratings should be reduced in accordance with Note 2 below and for cables which may be covered, Note 3 below. 2. Flexible cables wound on reeling drums The current ratings of cables used on reeling drums are to be reduced by the following factors: a) Radial type drum b) Ventilated cylindrical type drum ventilated: 85% 1 layer of cable: 85% unventilated: 75% 2 layers of cable: 65% 3 layers of cable: 45% 4 layers of cable: 35% A radial type drum is one where spiral layers of cable are accoodated between closely spaced flanges; if fitted with solid flanges the ratings given above should be reduced and the drum is described as non-ventilated. If the flanges have suitable apertures the drum is described as ventilated. A ventilated cylindrical cable drum is one where layers of cable are accoodated between widely spaced flanges and the drum and end flanges have suitable ventilating apertures. 3. Where cable may be covered over or coiled up whilst on load, or the air movement over the cable restricted, the current rating should be reduced. It is not possible to specify the amount of reduction but the table of rating factors for reeling drums can be used as a guide. 4. For 180 o C cables, the rating factors for ambient temperature allow a conductor operating temperature up to 150 o C. Consult the cable manufacturer for further information. 5. Where it is intended to connect the cables in this table to equipment or accessories designed to operate at a temperature lower than the maximum operating temperature of the cable, the cables should be rated at the maximum operating temperature of the equipment or accessory (see Regulations 512.1.5). 6. Where it is intended to group a cable in this table with other cables, the cable should be rated at the lowest of the maximum operating temperatures of any of the cables in the group (see Regulations 512.1.5). TECHNICAL TABLES 125

Table 4F2B TECHNICAL TABLES Voltage Drop (per ampere per metre): Conductor cross-sectional area 1 two-core or 2 single-core cables d.c. Two-core cable, single-phase a.c. Conductor Operating Temperature: 90 o C 1 three-core, four-core or five-core cable, three-phase a.c. 2 single-core cables touching Single-phase a.c.* 1 2 3 4 6 ( 2 ) (mv/a/m) (mv/a/m) (mv/a/m) (mv/a/m) 4 13.2 13.2 11.1-6 8.5 8.5 7.4-10 5.1 5.1 4.4-16 3.2 3.2 2.7 - r x z r x z r x z 25 2.03 2.03 0.175 2.04 1.73 0.15 1.73 - - - 35 1.42 - - - 1.22 0.15 1.23 1.44 0.21 1.46 50 1.00 - - - 0.91 0.145 0.93 1.00 0.21 1.02 70 0.71 - - - 0.62 0.14 0.64 0.71 0.20 0.73 95 0.54 - - - 0.47 0.135 0.49 0.54 0.195 0.57 120 0.42 - - - 0.37 0.135 0.39 0.42 0.190 0.46 150 0.34 - - - 0.29 0.130 0.32 0.34 0.190 0.39 185 0.27 - - - 0.24 0.130 0.27 0.27 0.190 0.33 240 0.21 - - - 0.188 0.130 0.23 0.21 0.185 0.28 300 0.167 - - - 0.147 0.125 0.195 0.173 0.180 0.25 400 0.127 - - - - - - 0.132 0.175 0.22 500 0.100 - - - - - - 0.107 0.170 0.20 630 0.074 - - - - - - 0.085 0.170 0.190 Notes: 1. The voltge drop figures given above are based on a conductor operating temperature of 90 o C and are therefore not accurate when the operating temperature is in excess of 90 o C. In the case of the 180 o C cables with a conductor temperature of 150 o C the above resistive values should be increased by a factor of 1.2. 2. *A larger voltage drop will result if the cables are spaced. 126

Table 4F3A Flexible Cords, Non-Armoured Current-carrying Capacity (amperes): and Mass Supportable (kg): Conductor cross-sectional area Current-carrying capacity Single-phase a.c. Three-phase a.c. Maximum mass supportable by twin flexible cord (see Regulations 522.7.2 and 559.6.1.5) 1 2 3 4 ( 2 ) (A) (A) (kg) 0.5 3 3 2 0.75 6 6 3 1 10 10 5 1.25 13-5 1.5 16 16 5 2.5 25 20 5 4 32 25 5 TECHNICAL TABLES Where cable is on a reel see the notes to the table in 4F1A. Rating Factor for Ambient Temperature 60 o C Thermoplastic or Thermosetting Insulated Cords: Ambient Temperature: 35 o C 40 o C 45 o C 50 o C 55 o C Correction Factor: 0.91 0.82 0.71 0.58 0.41 90 o C Thermoplastic or Thermosetting Insulated Cords: Ambient Temperature: 35 o C to 50 o C 55 o C 60 o C 65 o C 70 o C Correction Factor: 1.0 0.96 0.83 0.67 0.47 180 o C Thermosetting Insulated Cords: Ambient Temperature: 35 o C to 120 o C 125 o C 130 o C 135 o C 140 o C 145 o C Correction Factor: 1.0 0.96 0.85 0.74 0.60 0.42 Glass Fibre Cords: Ambient Temperature: 35 o C to 150 o C 155 o C 160 o C 165 o C 170 o C 175 o C Correction Factor: 1.0 0.92 0.82 0.71 0.51 0.40 127

Table 4F3B TECHNICAL TABLES Voltage Drop (per ampere per meter): Conductor Operating Temperature: 60 o C* Conductor cross-sectional area d.c. or single-phase a.c. Three-phase a.c. 1 2 3 ( 2 ) (mv/a/m) (mv/a/m) 0.5 93 80 0.75 62 54 1 46 40 1.25 37-1.5 32 27 2.5 19 16 4 12 10 Note: * The tabulated values above are for 60 o C thermoplastic or thermosetting insulated flexible cables and for other types of flexible cable they are to be multiplied by the following factors: For 90 o C thermoplastic or thermosetting insulated 1.09 150 o C 1.31 185 o C glass fibre 1.43 128

AWG/Metric Conversion American Wire Gauge to Metric Conversion - Listed below are some of the most popular strandings, however, many other combinations exist. Resistance figures are approximate and are given for guidance only. AWG Cross section 2 Stranding Resistance Ohm/km 38 0.008 1 x 0.10 2,125 38 0.009 7 x 0.04 1,930 36 0.013 1 x 0.12 1,360 36 0.014 7 x 0.05 1,217 34 0.020 1 x 0.16 856 34 0.022 7 x 0.06 777 32 0.032 1 x 0.20 538 32 0.034 7 x 0.08 538 32 0.035 19 x 0.05 446 30 0.051 1 x 0.25 338 30 0.057 7 x 0.10 338 30 0.059 19 x 0.06 286 28 0.080 1 x 0.32 213 28 0.089 7 x 0.12 213 28 0.090 19 x 0.08 186 26 0.128 1 x 0.40 134 26 0.141 7 x 0.16 122 26 0.155 19 x 0.10 113 24 0.205 1 x 0.51 84 24 0.227 7 x 0.20 76 24 0.241 19 x 0.12 69 22 0.324 1 x 0.64 53 22 0.355 1 x 0.25 48 22 0.382 19 x 0.16 45 20 0.519 1 x 0.81 33 20 0.563 7 x 0.32 30.4 20 0.616 19 x 0.20 28.3 18 0.785 16 x 0.25 21.2 18 0.823 1 x 1.02 20.9 AWG Cross section 2 Stranding Resistance Ohm/km 18 0.90 7 x 0.40 19.2 18 0.96 19 x 0.25 17.9 16 1.30 1 x 1.29 13.2 16 1.23 19 x 0.28 14.0 14 2.08 1 x 1.62 8.28 14 1.94 19 x 0.36 8.86 12 3.31 1 x 2.05 5.20 12 3.08 19 x 0.45 5.58 10 5.26 1 x 2.58 3.28 10 5.26 19 x 0.6 3.28 8 8.38 1 x 3.26 2.06 8 8.35 19 x 0.75 2.06 6 13.29 1 x 4.11 1.59 6 13.29 19 x 0.96 1.59 4 21.15 1 x 5.18 0.815 4 21.14 19 x 1.19 0.815 2 33.63 1 x 6.54 0.513 2 33.61 19 x 1.50 0.513 1 42.41 1 x 7.34 0.424 1 42.38 19 x 1.68 0.424 1/0 53.4 19 x 1.89 0.253 2/0 67.4 19 x 2.17 0.291 4/0 107 19 x 2.68 0.182 250MCM 127 37 x 2.09 0.139 300MCM 152 37 x 2.29 0.119 350MCM 177 37 x 2.47 0.102 400MCM 202 37 x 2.64 0.091 500MCM 253 37 x 2.95 0.072 TECHNICAL TABLES 129

Stranding Chart TECHNICAL TABLES Cross section 2 Nearest AWG size* Stranding class 1 Stranding class 2 IEC 60228/BS 6360 Conductors for insulated cables Resistance Ohm/km classes 1 & 2 Stranding class 5 Stranding class 6 Resistance Ohm/km classes 5 & 6 Approx weight 0.14 26 - - - - 18 x 0.10 138 1.35 0.25 24 - - - 14 x 0.16 32 x 0.10 79 2.4 0.34 22 - - - 19 x 0.16 42 x 0.10 57 3.3 0.50 20 1 x 0.80 7 x 0.30 36.0 16 x 0.21 28 x 0.16 38 4.8 0.75 18 1 x 0.97 7 x 0.37 24.5 24 x 0.21 42 x 0.16 26 7.2 1.0 18 1 x 1.13 7 x 0.43 18.1 32 x 0.21 56 x 0.16 19.5 9.6 1.5 16 1 x 1.38 7 x 0.53 12.1 30 x 0.26 84 x 0.16 13.3 14.4 2.5 14 1 x 1.78 7 x 0.67 7.41 50 x 0.26 140 x 0.16 7.98 24 4.0 12 1 x 2.26 7 x 0.85 4.61 56 x 0.31 224 x 0.16 4.95 38 6.0 10 1 x 2.76 7 x 1.04 3.08 84 x 0.31 192 x 0.21 3.3 58 10 8 1 x 3.57 7 x 1.35 1.83 80 x 0.41 320 x 0.21 1.91 96 16 6 1 x 4.5 17 x 1.70 1.15 128 x 0.41 512 x 0.21 1.21 154 25 4-7 x 2.14 0.72 200 x 0.41 800 x 0.21 0.78 240 35 2-7 x 2.52 0.52 280 x 0.41 1,120 x 0.21 0.55 336 50 1/0-19 x 1.78 0.39 400 x 0.41 705 x 0.31 0.39 480 70 2/0-19 x 2.14 0.27 356 x 0.51 990 x 0.31 0.27 672 95 3/0-19 x 2.52 0.19 485 x 0.51 1,340 x 0.31 0.21 912 120 250MCM - 37 x 2.03 0.15 614 x 0.51 1,690 x 0.31 0.16 1,152 150 300MCM - 37 x 2.25 0.12 765 x 0.51 2,123 x 0.31 0.13 1,440 185 400MCM - 37 x 2.52 0.1 944 x 0.51 1,470 x 0.41 0.11 1,776 240 500MCM - 61 x 2.25 0.07 1,225 x 0.51 1,905 x 0.41 0.08 2,304 300 600MCM - 61 x 2.52 0.06 1,530 x 0.51 2,385 x 0.41 0.064 2,880 400 750MCM - 61 x 2.85 0.05 2,035 x 0.51-0.068 3,840 500 1,000MCM - 61 x 3.20 0.04 1,768 x 0.60-0.0384 4,800 Notes: The number of strands according to IEC 60228/BS 6360 shown in classes 1 & 2 is obligatory. Stranding shown in classes 5 & 6 gives the maximum strand diameters and may have less strands provided the conductor does not exceed the resistance figures shown. In either case the standard gives the maximum resistance in ohms/km that is permissable for non-tinned conductors. * AWG sizes are approximate and for information only. Please contact us for exact sizing. 130

DIN 47100 European Colour Codes The DIN 47100 standard specifies the core colour of up to 44 cores. Above this it is usual practice to repeat the colours. The first colour is the colour of the base insulation and the second colour is that of either a longitudinal stripe or printed rings. Core Colour Core Colour 1 White 23 White/Red 2 Brown 24 Brown/Red 3 Green 25 White/Back 4 Yellow 26 Brown/Black 5 Grey 27 Grey/Green 6 Pink 28 Yellow/Grey 7 Blue 29 Pink/Green 8 Red 30 Yellow/Pink 9 Black 31 Green/Blue 10 Violet 32 Yellow/Blue 11 Grey/Pink 33 Green/Red 12 Red/Blue 34 Yellow/Red 13 White/Green 35 Green/Black 14 Brown/Green 36 Yellow/Black 15 White/Yellow 37 Grey/Blue 16 Yellow/Brown 38 Pink/Blue 17 White Grey 39 Grey/Red 18 Grey/Brown 40 Pink/Red 19 White/Pink 41 Grey/Black 20 Pink/Brown 42 Pink/Black 21 Pink/Brown 43 Blue/Black 22 Brown/Blue 44 Red/Black TECHNICAL TABLES 131

TECHNICAL TABLES Colour Codes BS 5308 BS 5308 Part 1 Colour Code Table 1 Unscreened & Collective Screened Pair no. A - wire B - wire 1 Black Blue 2 Black Green 3 Blue Green 4 Black Brown 5 Blue Brown 6 Green Brown 7 Black White 8 Blue White 9 Green White 10 Brown White 11 Black Red 12 Blue Red 13 Green Red 14 Brown Red 15 White Red 16 Black Orange 17 Blue Orange 18 Green Orange 19 Brown Orange 20 White Orange 21 Red Orange 22 Black Yellow 23 Blue Yellow 24 Green Yellow 25 Brown Yellow Pair no. A - wire B - wire 26 White Yellow 27 Red Yellow 28 Orange Yellow 29 Black Grey 30 Blue Grey 31 Green Grey 32 Brown Grey 33 White Grey 34 Red Grey 35 Orange Grey 36 Yellow Grey 37 Black Grey 38 Blue Grey 39 Green Violet 40 Brown Violet 41 White Violet 42 Red Violet 43 Orange Violet 44 Yellow Violet 45 Grey Violet 46 Black Turquoise 47 Blue Turquoise 48 Green Turquoise 49 Brown Turquoise 50 White Turquoise Single Quad (2 pair): Black, Blue, Green, Brown Single Triple: Blue, Black, Green Individually screened pairs can also be identified by a polyester tape over black and purple pairs. 132

Colour Codes BS 5308 BS 5308 Part 2 Colour Code Table 2 Unscreened & Collective Screened Pair no. A - wire B - wire 1 White Blue 2 White Orange 3 White Green 4 White Brown 5 White Grey 6 Red Blue 7 Red Orange 8 Red Green 9 Red Brown 10 Red Grey 11 Black Blue 12 Black Orange 13 Black Green 14 Black Brown 15 Black Grey 16 Yellow Blue 17 Yellow Orange 18 Yellow Green 19 Yellow Brown 20 Yellow Grey 21 White-Blue Blue 22 White-Blue Orange 23 White-Blue Green 24 White-Blue Brown 25 White-Blue Grey Pair no. A - wire B - wire 26 Red-Blue Blue 27 Red-Blue Orange 28 Red-Blue Green 29 Red-Blue Brown 30 Red-Blue Grey 31 Blue-Black Blue 32 Blue-Black Orange 33 Blue-Black Green 34 Blue-Black Brown 35 Blue-Black Grey 36 Yellow-Blue Blue 37 Yellow-Blue Orange 38 Yellow-Blue Green 39 Yellow-Blue Brown 40 Yellow-Blue Grey 41 White Orange Blue 42 White Orange Orange 43 White Orange Green 44 White Orange Brown 45 White Orange Grey 46 Orange-Red Blue 47 Orange-Red Orange 48 Orange-Red Green 49 Orange-Red Brown 50 Orange-Red Grey TECHNICAL TABLES Single Quad (2 pair): Blue, Green, Orange, Brown Single Triple: Blue, White, Orange Individually screened pairs can also be identified by a polyester tape over white and blue pairs. 133

Appendix TECHNICAL TABLES Harmonized Cable Core Colours 1 Introduction The requirements of BS 7671 were harmonized with the technical intent of CENELEC Standard HD 384.5.514: Identification, including 514.3: Identification of conductors, now withdrawn. Amendment No 2: 2004 (AMD 14905) to BS 7671:2001 implemented the following: The harmonized cable core colours and the alphanumeric marking of the following standards: HD 308 S2:2001 Identification of cores in cables and flexible cords BS EN 60445:2000 Basic and safety principles for man-machine interface, marking and identification of equipment terminals and of terminations BS EN 60446:2000 Basic and safety principles for man-machine interface, marking and identification. Identification of conductors by colours or numerals. This appendix provides guidance on marking at the interface between old and harmonized colours and marking general guidance on the colours to be used for conductors. In the British Standards for fixed and flexible cables the colours have been harmonized. BS 7671 has been modified to align with these cables, but also allows other suitable methods of marking connections by colour (tapes, sleeves or discs), or by alphanumerics (letters and/or numbers). Methods may be mixed within an installation. 2 Addition or alteration to an existing installation 2.1 Single-phase installation An addition or an alteration made to a single-phase installation need not be marked at the interface provided that: i) the old cables are correctly identified by the colour red for line and black for neutral, and ii) the new cables are correctly identified by the colour brown for line and blue for neutral. 2.2 Two- or three-phase installation Where an addition or alteration is made to a two- or three-phase installation wired in the old core colours with cable to the new core colours, unambiguous identification is required at the interface. Cores should be marked as follows: Neutral conductors Old and new conductors: N Line conductors Old and new conductors: L1, L2, L3. Table 7A - Example of conductor marking at the interface for additions and alterations to an a.c. installation identified with the old cable colours Function Old conductor New conductor Colour Marking Marking Colour Line 1 of a.c. Red L1 L1 Brown(1) Line 2 of a.c. Yellow L2 L2 Black(1) Line 3 of a.c. Blue L3 L3 Grey(1) Neutral of a.c. Black N N Blue Protective conductor Green-and-yellow Green-and-yellow 134

Appendix 3 Switch wires in a new installation or an addition or alteration to an existing installation Where a two-core cable with cores coloured brown and blue is used as switch wires, both conductors being line conductors, the blue conductor should be marked brown or L at its terminations. 4 Intermediate and two-way switch wires in a new installation or an addition or alteration to an existing installation Where a three-core cable with cores coloured brown, black and grey is used as switch wires, all three conductors being line conductors, the black and grey conductors should be marked brown or L at their terminations. 5 Line conductors in a new installation or an addition or alteration to an existing installation Power circuit line conductors should be coloured as in Table 51. Other line conductors may be brown, black, red, orange, yellow, violet, grey, white, pink or turquoise. TECHNICAL TABLES In a two- or three-phase power circuit the line conductors may all be of one of the permitted colours, either identified L1, L2, L3 or marked brown, black, grey at their terminations to show the phases. 6 Changes to cable core colour identification Table 7B - Cable to BS 6004 (flat cable with bare cpc) Cable type Old core colours New core colours Single-core + bare cpc Red or black Brown or blue Two-core + bare cpc Red, black Brown, blue Alt. Two-core + bare cpc Red, red Brown, brown Three-core + bare cpc Red, yellow, blue Brown, black, grey Table 7C - Standard 600/1000V armoured cable BS 6346, BS 5467 or BS 6724 Cable type Old core colours New core colours Single-core Red or black Brown or blue Two-core Red, black Brown, blue Three-core Red, yellow, blue Brown, black, grey Four-core Red, yellow, blue, black Brown, black, grey, blue Five-core Red, yellow, blue, black, green-and-yellow Brown, black, grey, blue, green-and-yellow Table 7D - Flexible cable to BS 6500 Cable type Old core colours New core colours Two-core Brown, blue No change Three-core Brown, blue, green-and-yellow No change Four-core Black, blue, brown, green-and-yellow Brown, black, grey, green-and-yellow Five-core Black,blue, brown, black, green-and-yellow Brown, black, grey, blue, green-and-yellow 135

Appendix TECHNICAL TABLES 7 Addition or alteration to a d.c. installation Where an addition or alteration is made to a d.c. installation wired in the old core colours with cable to the new core colours, unambiguous identification is required at the interface. Cores should be marked as follows: Neutral and midpoint conductors Old and new conductors: Line conductors Old and new conductors: Old and new conductors: M Brown or grey, or L, L+ or L-. Table 7E - Example of conductor marking at the interface for additions and alterations to a d.c. installation identified with the old cable colours Function Old conductor New conductor Colour Marking Marking Colour Two-wire unearthed d.c. power circuit Positive of two-wire circuit Red L+ L+ Brown Negative of two-wire circuit Black L- L- Grey Two-wire earthed d.c. power circuit Positive (of negative earthed) circuit Red L+ L+ Brown Negative (of negative earthed) circuit Black M M Blue Positive (of positive earthed) circuit Black M M Blue Negative (of positive earthed) circuit Blue L- L- Grey Three-wired d.c. power circuit Outer positive of two-wire circuit Red L+ L+ Brown derived from three-wire system Outer negative of two-wire circuit Red L- L- Grey derived from three-wire system Positive of three-wire circuit Red L+ L+ Brown Mid-wire of three-wire circuit Black M M Blue Negative of three-wire circuit Blue L- L- Grey The technical section information in this catalogue has been reproduced with permission of the Institution of Engineering and Technology and British Standards Institution. Copyright IET/BSI 2008. For more detailed information please refer to Requirements for Electrical Installations: IET Wiring Regulations 17 th Edition (BS7671: 2008 incorporating amendment number 1:2011) for reference. 136

INDEX 0361TQ Welding Cable 6 2182Y and 2183Y Flexible Cord for 31 Light Duty Applications 2491B/6701B Single Core 87 Equipment Wire 318TQ Cable 7 3182Y/H05VV-F and 3183Y Cable 31-32 Flexible Chord for Medium Duty Applications 3192Y and 2192Y Flexible Thin Flat 32 PVC Cable 638TQ Cable 9-10 657TQ Ship Wiring 11 658TQ Cable 13-15 A Arctic Cable 33 H H01N2-D and H01N2-E Welding Cable 16 H05RR-F Cable 17 H07RN-F Cable 105-106 H07RN-F Cable (BS7919:2001) 18-19 HIGH TEMPERATURE CABLES 77-87 E ENTERTAINMENT CABLES 104-107 Extra Flexible PVC Robotic Cable 88-90 Extra Flexible Screened Robotic Cable 91 L LiYCY Cable 29-30 Low Voltage Power Cable 53-56 LSZH Single Core Cable 63-64 INDEX B Bare Copper Single Core Cable 65 BS5308 Cable 36-39 C Cat 5E and CAT6 Cable 44 Coil End Lead Cable BS6195 21-22 CSE BMS 600V Rated Cable 47 CSE Socacable (number coded) 104 C-Tri-Rated Super Flexible Tri-Rated 86 Panel Wires CW 1128 Telephone Cable 46 CW 1308 Internal Telephone Cable 45 D DATA/TELEPHONE CABLES 34-47 Data Cables 40-43 Defence Standard Cables 34-35 F FIRE ALARM CABLES 72-76 FLEXIBLE RUBBER CABLES 6-24 FLEXIBLE CONTROL CABLES 25-33 N Neoprene Flatform Cable 99 (NGFLGOEU-J) Neoprene Flatform Screened Cable 100 NSHTÖU-J Drum Reeling Cable 23-24 NX200 Cable 72-75 NX200+ Cable 76 NYCY Energy Cable 70-71 NYY Power Cable 0.6/1KV 66-69 M Multicore Voltage Power Cable 48-51 P POWER CABLES 48-71 PVC Flatform Cable (H07VVH6-F) 98 PVC Single Core Cable 61-62 PUR Control Cable 92 PUR Extra Flexible Cable 94-95 PUR Extra Flexible Screened Cable 96-97 PUR Screened Control Cable 93 137

INDEX INDEX R Round Neoprene Cable with Strainer 20 ROBOTICS AND CRANE CABLES 88-103 S SID Cable 79 SIF Cable 77 SIF GL Cable 78 SiHF Cable 80 SIHF - Silicone Control Cable 107 SiHFP Cable 81-83 Single Core Low Voltage Power Cable 52 Single Core Medium Voltage 57-58 Power Cable SY Steel Wire Braid Cable 27-28 Submersible Pump TML Cable Flat 101 Submersible Pump TML Cable Round 102-103 T TECHNICAL CABLES 108-136 Three Core Medium Voltage 59-60 Power Cable Tri-Rated Panel Wires 84-85 Y YY-PVC Cable 25-26 138

CSE Cables Ltd Unit 16 Wessex Road Bourne End Bucks SL8 5DT Telephone: + (44) 1628 850024 Fax: + (44) 1628 648068 Email: o@csecables.com inf Or Skype us: csecables csemarketing cse_export Great effort has been made to ensure the accuracy of the information in this booklet. However products may vary due to manufacturing changes, technical improvements and coercial factors. In particular, overall diameters and weights are given for guidance only and if critical, they should be confirmed at time of order. All Trade Marks and Trade Names are acknowledged. Copyright CSE Cables Ltd 2012. All rights reserved. No part of this publication may be reproduced or replicated in any form without the express written permission of CSE Cables Ltd.