TC-600PD2. Switching Power Supply ( 600W PS2 ATX12V ) SPECIFICATION. Revision: 1.0

Similar documents
ST-250MAK-05E. Switching Power Supply SPECIFICATION

SPECIFICATION. SilverStone OLYMPIA OP1000 Switching Power Supply Active PFC

TC-2U70PD8. Switching Power Supply ( 2U 700W 80PLUS) SPECIFICATION. Revision: 2.0

TC-750PD8. Switching Power Supply ( PS2 ATX750W 8 0 PLU S ) SPECIFICATION. Revision: 1.0

SPECIFICATION ARP

SFX Form Factor SST-SX650-G SST-SX500-G. The standard SFX power supply benchmark

Product Specification

SPECIFICATION SWITCHING POWER SUPPLY BPS-300SP/2U 6-OUTPUT WITH ACTIVE PFC FUNCTION SINGLE POWER 300W BEST POWER SOLUTIONS, INC.

SPECIFICATION SWITCHING POWER SUPPLY SINGLE POWER 250W BEST POWER SOLUTIONS, INC. 9F, NO.196-7, SEC.3, TA-TUNG RD SHI CHIH, TAIPEI, TAIWAN, R.O.C.

SPECIFICATION REDUNDANT POWER SUPPLY HOT-SWAPPABLE 370W+370W

Matrix Power Company MH xxx-va series Specification Document

Switching Power Supply SPECIFICATION

SPECIFICATION SilverStone ST30NF for Standard Switching Power Supply With Active PFC PS/2 Fanless 300W

SPECIFICATION. SilverStone. 300W SFX Switching Power Supply FSP300-60GHS Meet 80 Plus Active PFC Circuit Full Range Input Small Size

SPECIFICATION ESD Released Date:2012/12/20-10:56:04

APPROVAL SHEET 12V/2A EA1019HHUS(03) EA1019HHUS-120 APP D EDAC POWER ELECTRONICS CO., LTD. TEL: FAX:

SPECIFICATION REDUNDANT POWER SUPPLY HOT-SWAPPABLE BPS-460RDX 6-OUTPUT 460W+460W BEST POWER SOLUTIONS, INC.

SPECIFICATION. SilverStone Zeus ST75ZF. Switching Power Supply. With Active PFC PS/2 750W

Line Reg Load Reg Ripple Efficiency *Model Number Output V Output I (nom/max) (nom/max) & Noise (min/nom)

OP650 -P. Single rail stepping up to a higher gear OP SERIES

SPECIFICATION ESD FSP500-60GHC. Released Date:2012/12/26-15:25:33

SPECIFICATION ESD FSP300-60GHT,(85)F. Released Date:2016/05/18-15:38:12

IS -500RSH1UP. Redundant Power Supply ( 1U- 500W ) SPECIFICATION. Revision: 1.0

DA850. The all around power DECATHLON

RoHS APPROVAL SHEET. ituner 12V/5A SERIES NO. (05) EA10523C-120 CUSTOMER CUSTOMER P/N DESCRIPTION EDAC MODEL DATE REVISION 0

SPECIFICATION ESD FSP460-60HCN. Released Date:2011/04/01-15:26:46

SPECIFICATION ESD Released Date:2012/09/28-18:39:41

SPECIFICATION ESD FSP250-60HNC. Released Date:2012/08/15-21:58:49

SSD3000 MODULE 280 WATT 12V FRONT END 8.66 x 1.99 x x 50.5 x 40mm

Rev. Page Item Date Description A2 4. MAR Update output rating & input voltage

APPROVAL SHEET I TUNER 12V/10.83A EA11703A(01) EA11703A-120 APP D EDAC POWER ELECTRONICS CO., LTD. TEL: FAX:

DSA150 Series. xxx Series. 150 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125.

ENHANCE SWITCHING POWER SUPPLY SPECIFICATION 250 WATT MODEL NO:V525

STRIDER ESSENTIAL SERIES SST-ST50F-ES230 Power for everything you need

DSR120 Series. xxx Series. 120 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details

VISION HISTORY Rev Level Rev Date Change Made Reason for Change Effective Approved By A 11/11/13 Specification Release S. Sadot A1 14/01/14 Update ope

The MDU150 Series provides the same benefits as the MPU150 Series, with nominal 48 volt DC input.

SPECIFICATION ESD Released Date:2013/12/23-18:11:46

PDAM500 Series 500W Power Supply

Electrical Specifications

This convection-cooled series is designed for use in commercial and industrial environments in temperatures up to 50 C.

PEAK OUTPUT CURRENT 1. MAP V 4.7V to 5.8V 8A 11A 0.2% ±1% 1% 4.9V to 5.1V PEAK OUTPUT CURRENT 4 LINE REGULATION

Product Specification sheet

CLP0205 Open Frame Power Supply Vac input; 5Vdc output; 200W Output Power; 0.25A stdby

Compliance. Safety Approvals USA Canada Europe. Isolation: General. Dimensions. AC Input CN1 Output CN2 Optional CN3. Weight

SPECIFICATION FOR APPROVAL

AC/DC Power Supply Single-Output

18093-PS PHIHONG TECHNOLOGY CO., LTD. General Specification PSM (DC)

MINI-ITX Power Supply

LCL Series. SIngle Output Industrial Supplies. High Efficiency. Low Cost. 150 W Convection Cooled. 300 W & 500 W with Internal Fans

Asia-Pacific North America Europe, Middle East Bel Power Solutions, Inc. BCD.

UMEC SMPS SPECIFICATION

SPECIFICATION ESD FSP600-80PSA(SK) Released Date:2017/02/08-10:47:01

HEC-45LTN-45PFAS Rev A

HEC-150RTN-48QSCA. A. Features. B. Description. C. Models. D. Electronic Specifications - Input Specifications

Single-output models feature wide-range output adjustability to meet a wide variety of standard and user-specific output voltage requirements.

NIGHTJAR SERIES SST-ST45NF. Optimum fan-less power supply with stability and silence

REDUNDANT AC 300W POWER SUPPLY. Technical Specifications TD-AC-300W-MAX

All specifications valid at normal input voltage, full load and +25 C after warm-up time unless otherwise stated.

INPUT VOLTAGE STARTING MINIMUM NORMAL MAXIMUM MAXIMUM INPUT RANGE VOLTAFE VOLTAGE VOLTAGE VOLTAGE CURRENT

AED500H22S Power Supply Product Specification. An APM Electronics USA, Inc. Power Supply Specification For ERP1U Power Supply

All specifications valid at normal input voltage, full load and +25 C after warm-up time unless otherwise stated.

Customer s Approval Signature

Medical Safety Approvals (-M versions) Industrial Heavy Duty Terminals. Output Power up to 1500 W. High Power Density - 18W/in 3

HEC-100RTA-48QSCA Rev A1.0

VOF XX - XXX - X

50W Constant Current (700mA) Dimming LED Driver

HEC-70LCN-350TDAF Rev B

HEC-30/35LTA-33TDAA Rev A

HEC-35LTA-XXTSAA Rev A

HEC-40LTN-XXPSCA Rev A

Output Voltage Output Amps Input Range Max. Iin FL Efficiency (Tb=25 C) O/P Set Point

Features. Regulated Converter. RAC02-SE/277/W 2 Watt Single Output. RAC02- SE/277/W Wired. AC/DC Converter

HRPG-1000 series. 1000W Single Output with PFC Function. File Name:HRPG-1000-SPEC Sicherheit ID

SPECIFICATION FOR APPROVAL

Customer s Approval Signature

IEC/EN/UL60950 & CE certified, EN55032 Class B

300W Industrial 1U ATX 12V/P4 PC Power Supply CH3 12V STANDBY 5VSB RATED CURRENT CURRENT RANGE 30A 1 ~ 30A 18A 1 ~ 18A

Parameter Condition Min. Typ. Max. Internal Input Filter 115VAC 230VAC 115VAC 230VAC. No load Power Consumption

AEA300R22S / AEA400R22S-1 Power Supply Product Specification

Customer s Approval Signature

TECHNICAL DATASHEET MDS Medical AC-DC Open Frame 065APS18 B Highlights & Features Safety Standards Model Number: Unit Weight Dimensions (W x L x H):

MTC Series 15 W AC/DC Switching Power Supply Module Medical

Doc. EA Model Number:

SFD550-12BG Front-End Preliminary Data Sheet DC Input, 12V Output, 550 Watts

TB65 65W Single Output Test and Measurement/Industrial Series

CLP0224 Open Frame Power Supply Vac input; 24Vdc output; 200W Output Power

UP1301A-( )( ) SERIES

REDUNDANT DC 200W POWER SUPPLY. Technical Specifications TD-DC-200W-12V

1000W Single Output Medical Type. MSP-1000 series. File Name:MSP-1000-SPEC

Output Current Range. Max. Output Power. 12 Vdc 90 ~ 305 Vac 10.8~13.2V 0~2900mA 35 W 82% EUV-035S012ST(3)

5 x 3 x 0.75 Inches form factor. 275 Watts with Forced Air Cooling. Efficiencies up to 92% Standby Power < 0.5 W

CLP0112 Open Frame Power Supply Vac input; 12Vdc output; 150W Output Power

Features. Regulated Converter. RAC02-SE/277 2 Watt Single Output RAC02- SE/277. AC/DC Converter

Max. Output Power. Efficiency (1) 110Vac 220Vac

75W Constant Current (700mA) LED Driver

Sirius 250/350 Watts, Single / Multi output AC-DC, modular power solution

70 Watt Switching Medical Grade Switching Power Supply with Active PFC CONTENTS 1. GENERAL CIRCUIT TOPOLOGY...2

Electrical Specifications

Specifications 2019-V AC-DC Switching Mode Power Supply NK-100 Series, 100W

Transcription:

Switching Power Supply ( 600W PS2 ATX12V ) SPECIFICATION Revision: 1.0 727,. Phillips Drive City of Industry. CA 91748. USA http:// www.xeal.com.tw TEL: 626-303-8885 FAX: 626-301-0588

** Table of Content ** 1. Input Requirements 04 1-1. Input Voltage 04 1-2. Frequency 04 1-3. Inrush Current. 04 1-4. AC Input Current. 04 1-5 Efficiency. 05 2. Output Requirements....... 05 2-1. Output Regulations...... 05 2-2. DC Load Requirements....... 05 2-3. Cross Regulation........ 06 2-4. +5V Standby Voltage.......... 06 2-5. DC Output Voltage Ripple And Noise...... 06 2-6. Total Output Power......... 06 2-7. Remote ON/OFF Control.... 07 2-8. Power Sequence.... 07 2-9. Power on Time (T1)..... 07 2-10. Rise Time (T2).... 07 2-11. Power Good Delay Time (T3).... 07 2-12. Power Good Rise Time (T4).. 08 2-13. Hold Up Time (T5). 08 2-14. Power Fail Signal (T6)...... 08 3. Protections..... 08 3-1. Over Voltage Protection....... 08 3-2. Short Circuit Protection....... 08 3-3. Protection Reset..... 09 3-4. Over Shoot........ 09 3-5. Over Power Protection..... 09 4. Environment....... 09 4-1. Operation/Storage Temperature Range...... 09 4-2. Humidity...... 09 4-3. Altitude..... 09 5. Safety...... 09 6. EMI Requirements.... 10 7. Dielectric Voltage Withstand (HI-POT)....... 10 2

8. PFC.... 10 9. Electrostatic Discharge Requirement (ESD).... 10 10. EFT/Burst.... 10 11. Surge.... 10 12. Burn-In.... 10 13. MTBF..... 10 14. Dimension 10 3

1. Input Requirements 1-1. Input Voltage The power supply shall be operated at universal input voltage defined in the following table. lnput Voltage MIN NOM MAX Voltage 90 100-240 264 1-2. Frequency The input frequency range is from 50Hz to 60Hz. 1-3. Inrush Current The max inrush current is 80A for 115/230VAC. 1-3-1. Cold Start Conditions 115/230VAC, full load. 25 ambient. Limits No component over stress or damage should occur to the power supply. Input fuse shall not blow. 1-3-2. Warm Start Conditions Limits Turn off at 132/264VAC full load No component over stress or for 1 sec then turn on at the peak damage should occur to the power of the input voltage cycle at 25 supply. ambient. Input fuse shall not blow. 1-4. AC Input Current AC Input MAX Units 100~240V 9 AMPS 4

1-5. Efficiency Maximum 76% at 115V and 80% at 230V, under loading of spec 2-2. 2. Output Requirements 2-1. Output Regulations Output Voltage Range MIN Nominal MAX Units +5V ±5% +4.80 +5.00 +5.25 Volts +12V1 ±5% +11.52 +12.00 +12.60 Volts +12V2 ±5% +11.52 +12.00 +12.60 Volts +12V3 ±5% +11.52 +12.00 +12.60 Volts +12V4 ±5% +11.52 +12.00 +12.60 Volts -12V ±10% -11.40-12.00-13.08 Volts +3.3V ±5% +3.20 +3.30 +3.46 Volts +5Vsb ±5% +4.85 +5.00 +5.25 Volts Note: 1). The above voltage range should also include ripple and noise. 2). The output voltage should be measured at the terminals of output connector. 2-2. DC Load Requirements Output Voltage MIN NOM MAX Units +5V 0.5 15 30 AMPS +12V1 0.5 8 16 AMPS +12V2 0.5 8 16 AMPS +12V3 0.5 8 16 AMPS +12V4 0.5 8 16 AMPS -12V 0.0 0.4 0.8 AMPS +3.3V 0.5 12.5 25 AMPS +5Vsb 0.0 1.5 3 AMPS Note : 1). The maximum continuous total DC output power shall not exceed 600 Watts. 2). The maximum continuous combined load on +5V and +3.3V outputs shall not exceed 170 Watts. 3). The maximum continuous combined load on +5V, +3.3V and +12V1,+12V2,+12V3,+12V4 2-3. Cross Regulation outputs shall not exceed 585 Watts. 5

The DC loads shall remain within the ranges specified in 2-2 DC Load Requirements and the DC output voltages also shall remain within the regulation ranges specified in 2-1 Output Regulation when measured at the load end of the output connectors. +5V +3.3V +12V1 +12V2 +12V3 +12V4-12V +5VSB 1 0.5 25 12 12 12 12 0.8 3 2 30 0.5 11 11 11 11 0.8 3 3 10 12 0.5 16 16 16 0.8 3 4 10 12 16 0.5 16 16 0.8 3 5 10 12 16 16 0.5 16 0.8 3 6 10 12 16 16 16 0.5 0.8 3 2-4. +5V standby voltage The +5Vsb is on whenever the AC power is present.-- 2-5. DC Output Voltage Ripple and Noise Output Voltage Ripple & Noise Max Units +5V 50 mv +12V1 120 mv +12V2 120 mv +12V3 120 mv +12V4 120 mv -12V 120 mv +3.3V 50 mv +5Vsb 50 mv Note : 1)The measurements should be made by crossing a 10uF/ electrolytic and a 0.1uF ceramic disk capacitors at each output with measuring bandwidth from DC to 20 MHz. If ambient temperature is under 20 or over 30, the AC input should be nominal input. 2-6. Total Output Power MAX Units 600 Watts 2-7. Remote ON/OFF Control 6

The power supply outputs shall be enabled with an active-low TTL signal. When TTL signal is low, the DC outputs are to be enabled. When TTL signal is high or open circuited, the DC outputs are to be disabled. Electronic means or a mechanical switch may activate the TTL signal. After the TTL signal is active high, must wait for 3 seconds before active low again. 2-8. Power Sequence AC IN On Off PS_ON T1 T5 95% +12V 10% +5V O/P s +3.3V T2 PG# T3 T4 T6 2-9. Power On Time (T1) MAX Units 500 ms 2-10. Rise Time (T2) MIN. MAX. Units 5 50 ms 2-11. Power Good Delay Time (T3) MIN. MAX. Units 100 500 ms The test environment is 25 condition @ nominal input. 2-12. Power Good Rise Time (T4) 7

MAX Units 10 ms 2-13. Hold Up Time (T5) MIN. Units 18 ms The test environment is 25 & full load condition @ nominal input. 2-14. Power Fail Signal (T6) Power good signal shall go to a down level 1ms before +5V output voltage falls below the regulation limits during PS-ON signal pull high. MIN. Units 1 ms 3. Protections 3-1. Over Voltage Protection When the DC outputs (+5V, +12V1,+12V2,+12V3,+12V4 +3.3V,-12V,+5VSB) have over voltage condition, the power supply shall provide latch mode over voltage protection. DC output Max Unit +12V1,+12V2,+12V3,+12V4 14.5 V +5V 6.5 V +3.3V 4.5 V -12V -14.5 V +5VSB 6.5 V 3-2. Short Circuit Protection A short circuit placed to ground shall cause no damage or power supply shall be shutdown. (The contact resistance is 0.05 ohm when the outputs short circuit.) 3-3. Protection Reset 8

When the power supply latches into shutdown condition due to a fault on an+5v,+3.3v,+12v1,+12v2 +12V3,+12V4 output(ocp, OVP, UVP), the protection shall reset after the fault has been removed, use remote on/off control or recycle the AC power again for a typical of 3 seconds. Note +3.3V OCP maximum 150%.+5V OCP maximum 150%.+12V1&12V2&+12V3&+12V4 OCP maximum 20A. 3-4. Over Shoot Any output overshoot at turn on shall be less than 15% of the nominal output value (with resistive load) as described in sec. 2.1. 3-5. Over Power Protection At 115/230Vac input the power supply will shut down all DC output within 110% to 150% of full load. 4. Environment 4-1. Operation/Storage Temperature Range Operation : 0 to 50 (nominal input) Storage : -40 to 70 LOAD 100% 70% 25 50 4-2. Humidity (none condensing) Operation: 20% to 85% RH(nominal input) Storage : 10% to 95% RH 5. Safety 5-1. UL60950-1, 5-2. TUV EN 60950-1 5-3. CB 6. EMI REQUIREMENTS 9

6-1.CE 6-2.BSMI 6-3.FCC part 15 sub part J class B at system load 6-4.CISPR 22 CLASS B 7. Dielectric Voltage Withstand (HI-POT) The power supply shall withstand for 3 seconds without breakdown the application of an 1800Vac-supply voltage applied between both input line and chassis (10mA AC Cutoff current). Isolating transformers shall similarly withstand 4242Vdc applied between both primary and secondary windings for a minimum of one minute. 8. PFC Active Power Factor Correction, complies with EN 61000-3-2: 1995+A1+A2:1998, Class D. 9. Electrostatic Discharge (ESD) Comply with IEC 61000-4-2. 10. EFT/ Burst Comply with IEC 61000-4-4. 11. Surge Comply with IEC 61000-4-5. 12. Burn-In Applying 115 Vac ± 10 % or 230 Vac ±10% input voltage and maximum load (80%) for this product in 45 ± 5 chamber. 13. M.T.B.F. The power supply shall have a minimum mean time between failure greater than 100,000 hours at continuous operation of 100% load and an ambient temperature of 25. 14. Dimension. 180(D)X 150(W)X 86(H) mm. 10