GRX Online Retroreflectivity Sensor User Manual

Similar documents
Instruction manual ADN-W AM. Antenna Module

Connevans.info. DeafEquipment.co.uk. This product may be purchased from Connevans Limited secure online store at

System Requirements: D-Link Systems, Inc.

TV Transmitter. User Guide Master

Part No. V V

ON!Track smart tag AI T380. English. Printed: Doc-Nr: PUB / / 000 / 02

Manual Unihan UPWL6580

Resusci Anne Advanced SkillTrainer

FSW-1650 FSW User Manual. 16/24-Port 10/100 Rackmount Switch

Wireless Z-Wave Control ZRP-100US Z-Wave Repeater USER MANUAL. Introduction

Owner s Manual MRX-10 Advanced Network System Controller

Manual Unihan UPWL6025

INSTRUCTION MANUAL. IBRit - rf1 - usb PC - Station for wireless Data transmission. M e s s t e c h n i k. Messtechnik GmbH & Co.

Resusci Anne Advanced SkillTrainer

Remote Control Outlets Operating Instructions

Transponder Reader TWN4 MultiTech 3 Quick Start Guide

Instruction Manual. for Media Monkey. 1

REMOTE CONTROL EXTENDER MODEL IR-320 CHO4009 OWNERS MANUAL R1848

CRUX II/BTGPS USER GUIDE. Model:D1598

English User's Guide

RFTX-1 Installation Manual

Connected Cooler Radio. Quick Start Guide

We recommend you keep the following records for reference, as well as a copy of your sales receipt: Serial number: Date of purchase:

Manual Unihan UPWL6024

Warning: Electrical Hazard... 3 Safety Instruction Sheet for STG Product Overview What s in the box?... 4

Operation and Maintenance Manual

SolarEdge Export Limitation Application Note

Active Transmitter Combiner 8:1 AC 3200-II. Instruction manual

AIS 300 Installation Instructions

Radio Micro Force Manual v1.1

Setup Guide. support.spruceirrigation.com.

Round shape, white case with 3M adhesive sticker, including 2pcs ER12450 battery and industrial package, special for indoor location, RoHS

Disclaimers. Important Notice

HORNET Remote Control Systems

USB RX Speed. Instructions for use Betriebsanleitung Mode d emploi Instrucciones para el uso Istruzioni per l uso

Bluetooth Sports Headphones

Complete guide to icube II. Wireless programming

User's Guide. Wireless AC Circuit Identifier. Models RT30 and RT32

User Manual. MITSUMI WiFi Module MODEL DWM-W081

A3 Size Flatbed Accessory for Kodak or Alaris Scanners

IS76 Beacon with Ferrite Antenna Installation Manual

Owner s Manual. MRX-2 Network Base Station

WML- 46### User Manual

Table of Contents. Makita LD050P 1

Operating Instructions

BT11 Hardware Installation Guide

Mini Hi-Fi Audio *MFL * SIMPLE MANUAL

SX-SDWAG a/b/g SDIO Module User Manual

IS76 Beacon with Ferrite Antenna Installation Manual

INSTALLATION MANUAL FOR SAL SERIES WIRELESS CLOCKS SPECIFICATIONS

MDW-45 Converter RS RS-422/485

Table of Contents. Stabila LD 320 1

Door/Window Sensor User Manual HKWL DWS02W

swarm radio Platform & Interface Description

ALPHA meter. General. Installation instructions IL S

INSTRUCTION MANUAL MODEL SAS RS-7 LASER DISTANCE METER

Owner s Manual. MRX-2 Network Base Station

P10 LASER DISTANCE MEASURE. IMPORTANT: Read before Using

802.11n, 2.4G 1T1R Wireless LAN PCI Express Half Mini Card

Mini Hi-Fi Audio *MFL * SIMPLE MANUAL

IMPORTANT SAFETY INSTRUCTIONS

Point Six Wireless Unique, High Value Wireless Solutions. 418 MHz Transmitter

User Manual. Snap AS02-PAR38NAE26 LED Bulb. Outdoor HD Security Camera with LED Floodlight

TM14-2.4G/R6014FS/R608FS Radio Control Instruction Manual

NV-WA40W. Installation and User Guide

Handheld Omnidirectional Laser Scanner

Quick Start Guide. Table of Contents

ACT-IR220Li/220LN IrDA Serial Port Adapter

HeLAN Motor Control Board

Thermo Bluetooth-enabled Thermometer. Model: EMR211 USER MANUAL CONTENTS

Assistive Listening System INSTRUCTION MANUAL MODEL #: ALS700

MPR kHz Reader

USER MANUAL. Sens it SENS IT 2.4

Do not expose this device to water or moisture of any kind. Do not mix new and old batteries or batteries of different types.

USERS MANUAL Section (C)(3)

INSTALLATION AND OPERATING MANUAL

DE EN FR IT ES RU PL DA NL NO SV

Quick Start Guide. Antenna Alignment Tool AIMWLLR0-35. QSG rev 7 AIMWLLR0-35 [NRB-0200] QSG.indd 1

DCH-G020 mydlink Connected Home Hub

Enphase. Mobile Connect Installation Guide

Product Manual. Getting Started with Roadie 2.

EPA152/252/502. User Manual.

Pocket Weatheradio with Tone and Vibrating Alert

Installation and Operation Manual MSI. Multi-Sensor Interface Hub. Interface Module for all Sensors Network and Wireless CAUTION

USER'S GUIDE. EcoQuest International 310 T. Elmer Cox Drive Greeneville, TN (423) Setup. Operation. Specifications.

CarConnect Bluetooth Interface General Motors Owner s Manual

WIRELESS FLASH TRIGGER V4 USER MANUAL

Darkglass Suite. Disclaimer

HARDWARE GUIDE. FlexIO Controller M2000 Series. Specifications and Operational Guide

Ambient Weather F007TH Wireless Thermo-Hygrometer User Manual

Darkglass Suite. Disclaimer

GREEN HERON ENGINEERING LLC

TRYM. TR-1 Tremolo Pedal. USER MANUAL TRYM TR- 1 User Manual rev , November, 2015

USER GUIDE FLEX. fishman.com

Supplement. ScanMaker i280 features, scenarios, and information. Getting to Know Your ScanMaker i280

S5-ADU. Front... 4 Rear... 4

User Guide Professional USB Recording Mic

Quick Start Guide. Version: 1.0 F/W: V1.2.0_RC1b. Date: December 11, 2017

ACT-IR220L/LE IrDA Serial Port Adapter

GX_W60_V3.5 WIFI Video module Mnaual

Transcription:

GRX Online Retroreflectivity Sensor User Manual Online sensor for production line control of the retroreflection properties of traffic sign sheeting materials. Manual August 2018 ver. 1.2 - English DELTA - Venlighedsvej 4-2970 Hørsholm - Denmark - Tel. +45 72 19 40 00 - roadsensors@delta.dk

Disclaimer The information contained in this document is subject to change without notice. DELTA MAKES NO WARRANTY OF ANY KIND WITH REGARD TO THIS MATERIAL, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTIC- ULAR PURPOSE. DELTA SHALL NOT BE LIABLE FOR ERRORS CONTAINED HEREIN OR FOR INCI- DENTAL OR CONSEQUENTIAL DAMAGES IN CONNECTION WITH THE FURNISHING, PERFORMANCE OR USE OF THIS MATERIAL. Intended use/purpose GRX Online is an industrial online sensor for quality control of retroreflective sheeting materials on indoor production line. Important Safety and Handling Information Caution: Changes/modifications not approved by the DELTA could void the user s authority to operate the equipment. Disposal and Recycling Information Please ask DELTA concerning disposal of GRX Online in your country. Visit our web-site: http://roadsensors.madebydelta.com/ GRX Online Retroreflectivity Sensor User Manual 2 DELTA a part of FORCE Technology

Supplier s Declaration of Conformity (SDoC) Unique identification of this SDoC: 80_GRX Online Sensor_SDoC_001 We, FORCE Technology Venlighedsvej 4 DK-2970 Hørsholm declare under our sole responsibility that the product: Product name: GRX Online Sensor Trade name: GRX Online Sensor Type or model: All types pursuant to the referenced trade name to which this attestation relates is in conformity with the essential requirements and other relevant requirements of ICES-003:2016 The product is verified according to: ICES-003:2016 (Class B) The equipment is accredited safety test with the internationally harmonized safety standard: IEC 60950-1:2005 (Second Edition) + Am 1:2009 + Am 2:2013 Supplementary information: - Technical file held by the undersigned. Place and date of issue (of this SDoC): Hørsholm 10-July-2018 Signed by or for the manufacturer:... (Signature of authorized person) Name (in print): Susan Bonde QA Manager, Product Division, Electronics & Microelectronics

Declaration of Conformity (DoC) Unique identification of this DoC: 80_GRX Online Sensor_EU_DoC_001 We, FORCE Technology Venlighedsvej 4 DK-2970 Hørsholm declare under our sole responsibility that the product: Product name: Trade name: Type or model: Serial / Batch no.: GRX Online Sensor GRX Online Sensor All types pursuant to the referenced trade name. From Serial number: 100 (incl.) to which this declaration relates is in conformity with the essential requirements and other relevant requirements of the: Electromagnetic Compatibility (EMC) Directive (2014/30/EU) EN 61326-1:2013, Industrial level, Class A EN 61000-3-2:2014 EN 61000-3-3:2013 Low Voltage (LVD) Directive (2014/35/EU) EN 61010-1:2010 (IEC 61010-1:2010, AMD:2016) EN 62471:2008 Restriction of the use of certain hazardous substances (RoHS) directive 2011/65/EU Assessment of components datasheets Supplementary information: - Technical file held by the undersigned. First year of CE marking: 2018 Place and date of issue (of this DoC): Hørsholm 10-July-2018 Signed by or for the manufacturer:... (Signature of authorized person) Name (in print): Susan Bonde QA Manager, Product Division, Electronics & Microelectronics

US Attestation of Conformity (AoC) Unique identification of this AoC: 80_GRX Online Sensor_AoC_001 We, FORCE Technology Venlighedsvej 4 DK-2970 Hørsholm declare under our sole responsibility that the product: Product name: GRX Online Sensor Trade name: GRX Online Sensor Type or model: All types pursuant to the referenced trade name to which this attestation relates is in conformity with the essential requirements and other relevant requirements of 47 CFR FCC Part 15. The product is exempted from other specific FCC rule parts than the general rule parts 15.5 and 15.29 pursuant to specific rule part 15.103(c), as it is intended solely for use as industrial test equipment. However, the product is verified according to the specific rule parts: 47 CFR Part 15B, subpart 15.107 (Class B) 47 CFR Part 15B, subpart 15.109 (Class B) The equipment is accredited safety test with the internationally harmonized safety standard: IEC 60950-1:2005 (Second Edition) + Am 1:2009 + Am 2:2013 Supplementary information: - Technical file held by the undersigned. Place and date of issue (of this AoC): Hørsholm 10-July-2018 Signed by or for the manufacturer:... (Signature of authorized person) Name (in print): Susan Bonde QA Manager, Product Division, Electronics & Microelectronics Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/tv technician for help.

Table of Contents GRX Online usage... 7 What does GRX Online measure?... 7 International measurement standards... 7 Overview of GRX Online... 8 Standard delivery... 8 Connecting the sensor... 8 Mounting the sensor in the production line... 8 Software installation... 9 Program location:... 9 Connecting to the sensor to the PC... 9 General... 9 Configuring the network adapter... 10 Calibration procedure... 11 Start/stop measuring... 12 Start/stop logging... 12 Appendix A: Specifications... 14 Optical characteristics... 14 Standards... 14 Electrical characteristics... 14 Environmental characteristics... 14 Mechanical characteristics... 14 Mechanical drawing... 15 GRX Online Retroreflectivity Sensor User Manual 6 DELTA a part of FORCE Technology

GRX Online usage GRX Online is an industrial sensor for continuously monitoring of retroreflective properties of sheeting materials at the production line. Retroreflective sheeting materials are used for traffic signs, high visibility safety clothing, license plates and, conspicuity materials. What does GRX Online measure? GRX Online measures the value RA (coefficient of retroreflected luminance at night). RA is an important factor in the on-site quality control of road traffic signs. International measurement standards The GRX Online measures the retroreflection and calculates RA according to international CEN and ASTM standards. The instrument complies with the following European and US standards: EN 12899: Fixed, Vertical Road Traffic Signs, part 1-5 Part 1: Fixed Signs & Part 4: Factory Production Control EN 20471: High-Visibility Clothing - Test Methods and Requirements ASTM E 1709: Standard Test Method for Measurement of Retroreflective Signs Using a Portable Retroreflectometer at a 0.2 degree Observation Angle ASTM E 2540: Standard Test Method for Measurement of Retroreflective Signs Using a Portable Retroreflectometer at a 0.5 degree Observation Angle ASTM E 1809: Standard Test Method for Measurement of High-Visibility Retroreflective-Clothing at a 0.2 degree Observation Angle and an Entrance Angle of -4 degree (discontinued). GRX Online Retroreflectivity Sensor User Manual 7 DELTA a part of FORCE Technology

Overview of GRX Online The GRX online sensor measures Ra values for a given entrance angle for seven observation angles. The GRX online sensor has a build in entrance angle of either -4 degrees (ASTM type) or 5 degrees (CEN type). The observations angles are 0.2, 0.33, 0.5, 0.7, 1.0, 1.5 and 2.0 degrees. All observations angels are measured simultaneously. The sensor measures all types and colors of retroreflective materials, when calibrated with one single white retroreflective standard with known R A. A calibrations standard can be supplied as an option by DELTA. Standard delivery o o o 1 pcs GRX Online Sensor. 1 pcs Power-over-ethernet injector. 1 pcs USB memory stick with PC control software and user guide. Connecting the sensor The online sensor is powered through the ethernet cable. Connect the sensor unit to the POE-injectors OUT socket* ). Connect the POE-injector IN socket to the PC* ). Connect the POE-injector power cable to an electrical outlet. *) Ethernet cables must be CAT5 or better. 90 to 264VAC input Power-over-ethernet Injector Ethernet GRX ONLINE SENSOR Ethernet PC When the sensor is powered correct the green LED on the rear cover plate will be flashing slowly (1 Hz). Mounting the sensor in the production line Mount the sensor so the black end cover (with the measurement window) is parallel to the sheeting and with approximately 100 mm. The illumination angle (-4 or +5 degrees) is determined by the internal optics. See the section Mechanical drawing GRX Online Retroreflectivity Sensor User Manual 8 DELTA a part of FORCE Technology

Software installation Double-click the setup file (eg. on the enclosed USB stick). When the install window shows up click Install After a few seconds the program is installed, and the program starts up: Program location: The program is installed in the default Windows program location: C:\Users\<Your user name>\appdata\roaming\microsoft\windows\start Menu\Programs\DELTA Furthermore, a short cut is placed on the Windows desktop. Connecting to the sensor to the PC General The sensor communicates over ethernet. The computer running the control software must be configured to access the sensor. Note: If the ethernet port on the pc is used for other purpose you can purchase an USB to ethernet adaptor to get an ethernet port The sensor is configured with a fixed IP address on the private subnet 10.201.201.0. Sensor IP address (fixed): 10.201.201.5 The control computer should be configured with a fixed IP address on the same subnet. The proposed network configuration is this: Fixed IP address: 10.201.201.2 Netmask: 255.255.255.0 GRX Online Retroreflectivity Sensor User Manual 9 DELTA a part of FORCE Technology

Configuring the network adapter Open the Control Panel and start Network and Sharing center, then select Change adapter settings and then select Properties Select Internet Protocol Version 4 (TCP/IPv4) and click Properties Select Use the following IP address: Enter IP address: 10.201.201.2 Enter subnet mask: 255.255.255.0 Click OK and Close GRX Online Retroreflectivity Sensor User Manual 10 DELTA a part of FORCE Technology

Calibration procedure The sensor does not compensate for the distance to the sheeting. Therefore, it is necessary to perform the calibration with the calibration target in the actual measuring distance. Place the calibration target in the same distance as the sheeting. Start streaming to help position the calibration target. The illuminated circle should be in the center of the calibration target. Stop streaming when the target is positioned correctly. Click Calibrate and enter the calibration values for each observation angle. Enter the calibration values in the calibration window: Click Calibrate to perform the calibration. Click OK to close the confirmation window. GRX Online Retroreflectivity Sensor User Manual 11 DELTA a part of FORCE Technology

Start streaming while the calibration target is still in place to verify that the measured data matches the values entered. Start/stop measuring Stream: Measurement period must be at least 200 milliseconds. The actual measuring time is approximately 50 milliseconds shorter. In general, the lower measuring times result in lower precision, i.e. greater variations in the measurement results. When the sensor is measuring the green LED on the rear cover plate will be flashing quickly (10 Hz). The measurement grid scrolls automatically when a measurement is received. The grid can hold a maximum of 50.000 measurements. When the limit is reached, the oldest measurements are removed from the grid. Start/stop logging Select Start log to start logging measurements to a file. The current logfile is shown in the status bar: If a file with the same name already exists, the measurement data will be appended. GRX Online Retroreflectivity Sensor User Manual 12 DELTA a part of FORCE Technology

The log file is in TAB-delimited ASCII format. Example: ;Number Timestamp Ra02 Ra033 Ra05 Ra07 Ra10 Ra15 Ra20 8 2016-11-01 12:54:05.391 276 203 106 35 17 13 6 9 2016-11-01 12:54:05.890 276 203 106 35 17 13 6 10 2016-11-01 12:54:06.390 276 203 106 35 17 13 6 GRX Online Retroreflectivity Sensor User Manual 13 DELTA a part of FORCE Technology

Appendix A: Specifications Optical characteristics Measurement aperture:... Ø25 mm / 1 inch Observation angles:... 0.2, 0.33, 0.5, 0.7, 1.0, 1.5, 2.0 Entrance angle (ASTM Type):... -4 (when mounted parallel to the web) Entrance angle (DIN Type) Optional:... +5 (when mounted parallel to the web) Distance from sensor to web:... 0-200 mm / 0-7.9 inch Reading range:... 0-2000 cd lx -1 m -2 Calibration:...User-supplied calibrated standard Light source angular aperture:... 0.1 Receptor angular aperture:... 0.1 Light source:... Illuminant»A«Receptor sensitivity:... Eye corrected Standards ASTM:... E1709 & E2540 DIN:... 67520 & EN12899-1 FCC:... FCC part 15, Subpart B, Class A Electrical safety:... IEC 61010-1 Electrical characteristics Measurement time (variable):... 0.2-2 seconds / 5Hz - 0.5 Hz Power:... POE (Power Over Ethernet) Power consumption:... < 10W Data connection:... Ethernet 10/100 Environmental characteristics Operation temperature:... 0 C to +40 C (32 F to 104 F) Storage temperature:... -10 C to +60 C (14 F to 140 F) Humidity:... < 85%, Non-condensing Mechanical characteristics Length:... 270mm/10.6 inches Width:... 112 mm/4.4 inches Height:... 165 mm/6.5 inches Weight:... 2.5 kg/5.5 lbs Housing:... Aluminum Structural parts:... Aluminum GRX Online Retroreflectivity Sensor User Manual 14 DELTA a part of FORCE Technology

Mechanical drawing GRX Online Retroreflectivity Sensor User Manual 15 DELTA a part of FORCE Technology