Gutor PxW AC UPS Designed for North American Market

Similar documents
Technical Data Sheets

Technical Data Sheet. Uninterruptible Power Supply On-line VH Series UPS. Critical Power UL / 208V

TECHNICAL DATA SHEET B9600FXS kva

TOSHIBA International Corp

These true online inverters integrate pulse width modulation (PWM) control combined with high frequency IGBT power transistors.


2.1 Performance Standards The UPS is designed with the applicable sections of UL, CUL, and ISO The UPS has UL and CUL listing.

Series PCI + PIT PIT5738 U IN PIT5748 U IN PCI5748 PCI5738. Series PIT 19 - Cabinet G10

MODULAR DC POWER SUPPLIES & SYSTEMS. DC Power Systems DC/AC Inverters Static Switches DC/DC Converters. GAMATRONIC, A SolarEdge Division

PRODUCTS FOR ELECTRICAL SUB-STATIONS UPS, DC-AC INVERTERS, BATTERY CHARGERS, DC-DC CONVERTERS, 1-PHASE TO 3-PHASE CONVERTERS

These true on-line inverters incorporate pulse width modulation (PWM) control combined with high frequency igbt power transistors.

S11 Adjustable Speed Drive Engineering Specification

G8000MM Series IGBT. 100 to 750 KVA UPS UNINTERRUPTIBLE POWER SYSTEMS. 94% Efficiency. Input PF >0.98 DESIGN

R&D TECHNICAL SPECIFI

ADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W

SPECIFICATION. Online UPS 3000VA

StatiVolt. Inverter UPS Systems. Features. Contents

4Q POWER AMPLIFIERS AC AND DC 3000VA 3x3000VA

MAJORSINE Power Inverter

ADJUSTABLE SPEED DRIVES. W7 Series. 18 Pulse

OPUS C DC Power Systems OC2066 and OC1666 floor standing Cabinets

Inverter with static switch a. manual bypass up to 1000 VA

Product Catalog PRODUCT CATALOG. Power supply system & test equipment

VF-nC1 Adjustable Speed Drive Engineering Specification

ADJUSTABLE SPEED DRIVES. HX7 Series. 18-Pulse

PROTECT 8 INDUSTRIAL UPS. Protect 8.31 Single Phase output 10 kva 80 kva. Protect 8.33 Three Phase output 10 kva 120 kva. Engineering is our business

GUIDE SPECIFICATIONS 40-80kVA, kVA and kVA Scalable Three-Phase Uninterruptible Power System 1.0 GENERAL

Dale Power Solutions Ltd

GESS Industrial UPS System. Overview

Liebert Hipulse-U. Fully Digital Dual DSP Controlled Transformer Based UPS

AC CURRENT GENERATOR POC-6000 (current from 0 to 1000 ARMS)

Power Processor - Series 700F 10KVA to 150KVA

DC 4Q POWER AMPLIFIER 200kW 2 RANGES HIGH POWER RS232

Chloride 80-NET Secure Power For Mission Critical Applications 60kVA to 120kVA. AC Power For Business-Critical Continuity

APQline Active Harmonic Filters. N52 W13670 NORTHPARK DR. MENOMONEE FALLS, WI P. (262) F. (262)

POWER AMPLIFIERS 4 QUADRANTS 3x500 VA to 3x1500 VA - THREE-PHASES

Modbus Register Map: InfraStruXure Symmetra 3-Phase Absolute Starting Register Number, (Decimal)

SECTION THREE-PHASE UNINTERRUPTIBLE POWER SYSTEM

MITSUBISHI ELECTRIC 2033A DDC SERIES SPECIFICATIONS

Orbital GFI Inverter Series

DSA150 Series. xxx Series. 150 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125.

Power IT LV Active Filters PQFI PQFM PQFK. The ABB comprehensive solution for active filtering of harmonics

ADJUSTABLE SPEED DRIVES. HX7 Series. 18 Pulse. Phone: Fax: Web: -

NGS INVERTER REPLACEMENT SCOPE OF WORK & SPECIFICATIONS

RS232 AC-DC VOLTAGE POWER AMPLIFIERS PCU-10K / 15K / 20K / 24K-AB/4G/HP PERFORMANCES APPLICATIONS DESCRIPTION COMMERCIAL REFERENCES

22 kw 4Q POWER AMPLIFIER RS232

NAME OF (VENDOR/MANUFACTURER) Clause No. Clause Description Comments, if any Remarks, if any

This Chapter contains:

SOUTHERN AVIONICS COMPANY. SE125 Transmitter. SE125 Transmitter 1-1

1KVA-2KVA-3KVA 6KVA-10KVA. NUPS22 Series

EL-AC Electronic Load

2017 Advanced Energy Industries, Inc. HITEK POWER MV2000 SERIES MEDIUM-VOLTAGE HIGH-CURRENT POWER SUPPLIES

UNINTERRUPTIBLE POWER SUPPLY SPECIFICATIONS MODEL 1100B SERIES

ALL PRODUCT BROCHURE

3 x 30 kva AC POWER SOURCE PCU-3x30000-AC/DC-300V-100A-2G-HP RS232

MICROPROCESSOR-BASED METERING EQUIPMENT SECTION 16901C PART 2

Resilient 3000 EP3000AC48IN Rectifier 3000W Output at 48 58Vdc

E3 Adjustable Speed Drive Engineering Specification

Chloride. FP-50z 5 160kVA Industrial AC UPS

Technical Specifications

Phoenix DX Clean Power (18 Pulse) AC Drive

D SERIES EM16 IP 20 / NEMA 1 & IP 66 / NEMA 4X COMPACT VECTOR CONTROL DRIVE EM 16 COMPACT VECTOR CONTROL DRIVE

DOBLE F6150SV TECHNICAL SPECIFICATIONS

INPUT VOLTAGE STARTING MINIMUM NORMAL MAXIMUM MAXIMUM INPUT RANGE VOLTAFE VOLTAGE VOLTAGE VOLTAGE CURRENT

LCL Series. SIngle Output Industrial Supplies. High Efficiency. Low Cost. 150 W Convection Cooled. 300 W & 500 W with Internal Fans

STATIC UNINTERRUPTIBLE POWER SYSTEM Revised 4/30/ Electrical Systems

RS232. DC POWER SUPPLY 20kW 3 RANGES

Data Sheet. RISH Master Record %THD

PowerFlex 400 Submittal

Medical Safety Approvals (-M versions) Industrial Heavy Duty Terminals. Output Power up to 1500 W. High Power Density - 18W/in 3

RELIABLE SOLUTIONS in POWER ELECTRONICS VRST SERIES. Power Management Instruments ELECTRONIC STABILIZER FROM PMI & OES GROUP COMPANIES SUD

ATV12HU22M2. Main. Range of product Altivar 12. Component name Quantity per set Set of 1. Built-in fan. Motor power hp Communication port protocol

CROSS Chassis from 160 A to 450 A

SECTION LOW VOLTAGE ACTIVE HARMONIC FILTER SYSTEM NEMA 1 ENCLOSED

LAUREL ELECTRONICS, INC.

ATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink

SM2000 TECHNICAL DESCRIPTION

Series 7400 M (10/20/30/40/60 kva) Maximum Protection For Mission Critical Network Applications. Series 7400 M

An RS485 bus is used for command, monitoring and diagnostic information that can be supplied to a system controller.

BAT-Series Grid Inverter. Battery Charger.

1 INTRODUCTION ORDER CODE / INFORMATION

Metal Case Power Supplies

SHORE TO SHIP FREQUENCY

Chloride FP-60Z 5 to 60kVA

Utility Systems Technologies, Inc. Sag Fighter. Deep Voltage Sag Protection:

DIFFERENTIAL CURRENT GENERATOR «POCDIF» (AC/DC - 32A - 50V - 12 ranges)

Comm Series DC Power Supplies Radio Base Station Covers Battery Chargers DC UPS Backup Systems

PS-3000-AVAS PS-5000-AVAS DC SOURCE FOR AUTOMOTIVE TESTS

nd30 EXAMPlE OF APPliCATiON MEASUREMENT AND ViSUAliZATiON OF POWER NETWORk PARAMETERS Ethernet www/ ftp Modbus TCP Modbus RS-485

MT3200A TRAVELING WAVE TUBE MEDIUM POWER AMPLIFIER

ATV12HU40M3 variable speed drive ATV12-4kW - 5hp V - 3ph - with heat sink

new! nd30 - METER OF POWER NETWORk PARAMETERS EXAMPlE OF APPliCATiON MEASUREMENT AND ViSUAliZATiON OF POWER NETWORk PARAMETERS

CP-T range Product group picture

ATV12H018F1 variable speed drive ATV kW hp V - 1ph

DSR120 Series. xxx Series. 120 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details

SPECIFICATION REDUNDANT POWER SUPPLY HOT-SWAPPABLE 370W+370W

RISH EM 3490 DS Dual Source Energy Meter (With All Display Parameters) RISH EM 3490 DS. Application : Product Features:

CCH400 & CCH600 Series

PURE SINE WAVE INVERTERS WITH INTEGRATED BATTERY CHARGER FOR VEHICLES ECE R10-05 PURE SINE WAVE HIGH FREQUENCY INVERTERS FOR VEHICLES ECE R10-05

VIM Series. 90 & 60 W, Efficient, CV Class 2 LED Drivers ORDERING INFORMATION

Transcription:

Gutor PxW AC UPS Designed for North American Market PEW 5 200 kva single phase PDW 10 220 kva three phase Higher ratings upon request schneider-electric.com

2 schneider-electric.com

schneider-electric.com 3 Gutor TM PxW technical data: PEW single phase/pdw three phase UPS input Rectifier input voltage Voltage tolerance DC in tolerance For function Bypass input voltage Single phase Three phase Frequency Inrush current Intermediate DC circuit Voltage Rectifier voltage tolerance DC ripple voltage 3 x 208/480/600 V (other voltage upon request) +/- 10% -15/+10% 1 x 120/208/240/480/600 V (other voltage upon request) 3 x 208/480/600 V (other voltage upon request) 60 Hz +/- 8% (50 Hz available upon request) <10x IN (input current) 110/125/220/400 VDC +/- 1% I-V characteristic with battery capacity of 3x nominal current: 1% rms without battery: 2% rms, optional without battery: 1% rms Float voltage at -10% line power 100 115% programmable Boost voltage range at nominal line power 100 125% programmable Boost charge time 1 24 hour programmable Charging current limitation programmable Inverter input range (output tolerance +/- 1%) +20/-15% Inverter maximum input range (output tolerance +/- 10%) +/- 25% UPS output Nominal UPS Inverter rating kva at PF 1.0 Voltage Single phase Three phase Voltage tolerance Static within 0 100% load Dynamic at 100% load surge Regulation time Overload Inverter 1 min Inverter 10 min Bypass 100 ms 1 x 120/240 V (other voltage upon request) 3 x 208/480 V +/- 1% +/- 4% <25 ms 105% continuous 150% 125% 1,000% Short-circuit inverter 100 ms 200% Frequency 60 Hz +/- 8% (50 Hz available upon request) Frequency stability, free running <0.01% Synchronization range 0.5/1/2/4/6/8% Slew rate single units 0.25/0.5/1/2/4 Hz/s programmable Slew rate redundant system 4.0 Hz/s Wave form sinusoidal Admissible output crest factor unlimited Distortion factor Linear load Nonlinear load Allowable power factor Fault clearing capability General data 3% 5% 0.4 lag 0.9 lead 200% for 100 ms via inverter, 1,000% for 100 ms via bypass Ambient temperature range for storage from -20 to +70 C from -4 to +158 F Ambient temperature range for operation from -10 to +55 C from 14 to +131 F Altitude above sea level 1,000 m without load de-rating 3,280 ft without load de-rating Allowable air humidity <95% (non-condensing) Noise level standard n+1 fan system 60 75 dba depending on type Degree of protection NEMA 1 (IP20) Paint pearl light gray, RAL 9022 cabinet Efficiency up to 91% depending on type Cooling forced ventilation (two speed) with n+1 redundant, monitored fans Standards Safety EMC Performance Conformity Seismic UL 1778 / CSA 22.2-107.3 FCC Part 15 Subpart B, Class A NEMA PE-1 CE-Label up to 1.0 g

Bypass Test Auto 4 schneider-electric.com Gutor PxW specifications: PEW single phase/pdw three phase Typical single-line drawing Standard configuration Bypass -X090 -X001 Battery -Q001 -BAT -Q090 USV V/A -T001 -T090 Single-phase drawing -A030 Battery voltage and UPS ratings Single phase -L001 A -X002 V -Q004 -CB02 A -A032 A -L002 -T002 Voltage (VDC) 110 125 220 400 5 5 5 10 10 10 10 10 10 15 15 15 15 15 15 20 20 20 20 20 20 40 40 40 40 40 40 50 50 50 60 60 60 60 80 80 80 80 100 100 120 120 120 150 160 160 200 220 UPS ratings (kva) Three phase -CB03 -F028 -F021 V -A035 -A036 EN EA V/A/F -Q050 -X004 Single UPS UPS output voltage Single phase: 1 x 120 V Three phase: 3 x 480 V Rectifier input voltage: 3 x 480 V +10/-10% Bypass input voltage Single phase: 1 x 120 V +10/-10% Three phase: 3 x 480 V +10/-10% Frequency: 60 Hz +/- 8% 6-pulse rectifier with isolation transformer Rectifier sized for output PF = 0.8 Rectifier input breaker Fixed charging voltage IU characteristic Static switch EN (line power side) Static switch EA (inverter side) LC display unit with additional alarm LEDs Alarm relays for battery operation and common alarm Bottom cable entry Ground terminal N+1 monitored two-speed fans Ambient temperature range from +14 to +104 F NEMA 1 (IP20) Painting pearl light gray, RAL 9022 structure Battery MCCB in UPS Three position manual bypass switch Bypass backfeed protection Higher ratings and other voltages on request

schneider-electric.com 5 Options System Redundant/Parallel Load Sharing Configuration Redundant/Parallel Dual Configuration AC distribution AC and DC earth-fault monitoring Input harmonic filter Rectifier Rectifier input MCCB 12-pulse rectifier with isolation transformer Oversized rectifier Rectifier fuse Diode for reverse polarity protection Rectifier output isolator/circuit breaker Battery Battery circuit protection box (MCCB/fuse) Battery circuit protection in rectifier (MCCB/fuse) Low-voltage disconnect Battery management system (single cell type) Temperature sensor for temperature compensated battery charging Battery monitor (programmable battery data) Battery asymmetry supervision Inverter Inverter input isolator/circuit breaker Black start facility Oversized inverter

6 schneider-electric.com Bypass Bypass switch blocking coil Remote manual bypass switch Bypass input isolator/circuit breaker Bypass isolation transformer Bypass voltage regulating transformer Independent static bypass switch Indication and alarms Input power failure DC earth fault Inverter fuse blown DC out of tolerance 5x customizable options Bypass input power failure Rectifier fuse blown Fan failure Internal PSU fault Battery discharged System overtemperature EA inhibited (UPS output static switch) Battery disconnected Inverter ON EN inhibited (Bypass static switch) Battery operation Boost (Equalize) charge ON Manual bypass ON Rectifier failure Rectifier ON Asynchronous EA ON (UPS output static switch) External horn Inverter failure EN ON (Bypass static switch) Overload inverter/bypass Communication interfaces Front-panel analog meter Power meter Transducer Relay board, 16 fail-safe NO/NC contacts RS-232/485 interface (downloadable event log) RJ-45 Ethernet port for Web browser-based monitoring Modbus protocol on RS-485 or TCP/IP IEC 61850 protocol on RJ-45 and/or fiber optic connector Profibus on RS-485 External time synchronization Mechanical Top/bottom cable entry NEMA 12 per NEMA 250-1991 (IP52) Air filters at air inlet 100% redundant ventilation Seismic design Space heaters Panel lighting Cabinet color as required Ambient temperature maximum +131 F Allowable altitude up to 13,123 ft (4,000 m) above sea level Additional options are available upon request.

schneider-electric.com 7 Human-machine interface The front panel includes a comprehensive and flexible human-machine interface. It is divided into four sections: 1 2 1 2 3 4 The system panel shows the current state of operation and how power is being routed through the system to the load. The operations panel is used to turn the system on and off. The Lamp Test button indicates whether all LED indication lights on the front panel are functioning properly. The keypad is used to view system measurements and interact with the system. The alarm & indication panel displays possible faults and alarms. 3 4 Operational parameters Selectable second display language Bypass operation Boost charge Auto boost (equalize) charge Battery-capacity test Battery-monitor test (optional) Set date/time Measurements Load in percentage of nominal kva rating AC rectifier input voltage and current AC bypass input voltage Total DC current, battery voltage, and battery current Battery temperature (with optional sensor) AC Inverter current AC output voltage, current, and frequency AC output peak current Battery backup time remaining (optional with string type battery monitor) Event log with date and time (operating mode changes and alarms)

Headquarters Gutor Electronic LLC, Hardstrasse 72 74, 5430 Wettingen, Switzerland P +41 (0)56 437 34 34 F +41 (0)56 437 34 44 gutor.info@schneider-electric.com Gutor Electronic Asia Pacific Gutor Electronic Asia Pacific Sdn.Bhd No.19, Jalan Juruukur U1/19, Seksyen U1, Hicom Glenmarie Ind Park, 40150 Shah Alam, Selangor Malaysia Gutor Americas 12121 Wickchester Lane Suite 400, Houston, Texas 77079, USA P +888-994-8867 F +281-588-2199 gutor.usa@schneider-electric.com schneider-electric.com/gutor 2016 Schneider Electric. All Rights Reserved. Schneider Electric Life Is On and Gutor are trademarks and the property of Schneider Electric SE, its subsidiaries, and affiliated companies. All other trademarks are the property of their respective owners. 998-19781322_GMA-US This document has been printed on recycled paper