Condumax CLS15 and CLS15D

Technical Information Condumax CLS21D/CLS21

Condumax W CLS19. Technical Information. Conductivity sensors Two-electrode sensors with cell constants k = 0.01 cm 1 or k = 0.

Condumax CLS16 and CLS16D

Condumax W CLS15 and CLS15D

Technical Information Condumax CLS15D/CLS15

Condumax W CLS19. Technical Information. Conductivity sensors Two-electrode sensors with cell constants k = 0.01 cm 1 or k = 0.

Indumax CLS50/CLS50D. Technical Information

Orbipac CPF81/CPF82 and CPF81D/CPF82D

Technical Information Memosens CLS82D

Conductivity Sensor for High-Temperature Applications ConduMax W CLS 13

Technical Information Indumax CLS50D/CLS50

Conductivity Measuring Cells for High-Temperature Applications ConduMax H CLS 16

Technical Information Orbipac CPF81D/CPF82D and CPF81/CPF82

Ceramax CPS341D. Technical Information

Technical Information Orbipore CPS91D and CPS91

Memosens CPS96D. Technical Information

Memosens New technology for contactless, inductive, digital transmission of ph signals

Technical Information Memosens CPS96D

Indumax CLS54D. Technical Information

Technical Information Indumax CLS54

Liquisys M CLM223/253

Conductive conductivity measurement mypro CLM 431 / CLD 431 conductive

Tophit CPS491 and CPS491D

Indumax H CLS54. Technical Information

Technical Information Liquisys M CLM223/253

Inductive conductivity measurement mypro CLM 431 / CLD 431 inductive

Tophit CPS491 and CPS491D

Technical Information Smartec CLD18

Technical Information Smartec CLD18

Tophit CPS441 and CPS441D

0 2 1 â Ó. itemp HART TMT182. Technical Information

Digital conductivity transmitter

Smartec S CLD134. Technical Information

Flow Measurement SITRANS F M

Conductivity measurement SmarTec S CLD 132

Turbimax CUS71D. Technical Information. Ultrasonic interface sensor Immersion sensor for interface measurement

Technical Information Smartec CLD18

The transducer component converts the measured signal and displays the actual value.

SITRANS F flowmeters SITRANS F M. Flow sensor MAG /48 Siemens FI Overview

Flow Measurement SITRANS F M. Flow sensor MAG /49. Overview

Liquisys M COM223/253

OPTIFLUX 5000 Technical Datasheet

Coriolis Massflowmeter

â Ó itemp TC TMT128 Technical information DIN rail mounted Temperature Transmitter for Thermocouples (TC)

itemp PA TMT184 Technical information

Submersible pressure sensor For oils and fuels Model LF-1

OPTIFLUX 5000 Technical Datasheet

Submersible pressure sensor For water and wastewater Model LW-1

Endress Hauser. SmarTec M CLD 133 Conductivity Measurement

Technical Information Memosens CCS50D

0 2 1 â Ó. itemp HART TMT182. Technical Information

prosonic T FMU230, FMU231

SMARTPAT COND 1200 Technical Datasheet

Conductivity sensor for hygienic applications

ph/orp Measurement OPM223/253

Temperature transmitter itemp PCP DIN rail TMT 121

MJK Expert 700 / 800 / 900 / 1100 / 2100 MJK Expert 1400 / 3400

Submersible pressure sensor For superior applications Model LF-1

Liquisys M CPM223/253

itemp HART DIN rail TMT112

Conductivity measurement Mycom S CLM 153

Turbidity sensor TurbiMax W CUS 41

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

JUMO BlackLine CR-GT/-EC/-GS Conductive 2-Electrode Conductivity Sensor

ph / ORP Measurement mypro CPM 431

Temposonics. Magnetostrictive Linear Position Sensors. ET Analog Data Sheet

Level Measurement Continuous level measurement Radar transmitters

Coriolis Massflowmeter

Endress Hauser The Power of Know How. Turbidity and Solids Content Sensor TurbiMax P CUS 63 / CUS 63H

Level Measurement. Continuous level measurement - Radar transmitters SITRANS LR400 5/229. Overview

Mobrey Ultrasonic. MSP422, MSP400RH, and MSP900GH Level Transmitters. Product Data Sheet February 2015 IP2045, Rev EA

OPTIFLUX 1000 Technical Datasheet

Assembly 249 (9.80) 259 (10.2) Example: level probe with Pt100 and HUT temperature head transmitter ( ma) ma. Core colors: RD BK YE BU

Level Measurement. Continuous level measurement - Radar transmitters SITRANS LR400 5/229. Overview

Liquisys M CCM223/253

Rosemount 3101, 3102, and 3105

Solids Content Sensor OUS 41 / OUS 41-W

VITO LT. Global Experience. Locally Applied. A dependable choice.

Content. Flow meter F2-UN. Description Technical Data Dimension drawings Operation... 8 Mounting instructions...

Liquisys M COM223/253

LST100 Ultrasonic level transmitter for upstream oil and gas

OEM radar transmitter, for aggressive media level measurement

SITRANS F M MAGFLO Electromagnetic Flowmeters Explore the Siemens Solution. sitrans f

Technical Information Liquisys M CCM223/253

TEK-TEMP 2100A. Explosion-Proof Temperature Transmitter. TEMPERATURE. Technology Solutions

RADAR TRANSMITTERS BLISSFLEX 1100 SELECTION GUIDE. The characters of the order code have been described below

Level Measurement Continuous level measurement Radar transmitters

Intrinsically safe pressure transmitter MBS 4201, MBS 4251, MBS 4701 and MBS 4751

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. appmeas.co.uk +44 (0)

Signet ph/orp Electrodes

High-quality pressure transmitter For general industrial applications Model S-10

Temperature transmitter itemp RTD DIN rail TMT 127

Conductivity Analyzer

Industrial Conductivity (Electric Conductivity) Detector

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

Ultra high purity transducer, Ex na nl Models WU-20, WU-25 and WU-26

Transcription:

Technical Information Condumax CLS21 and CLS21D Conductivity sensors, analog or digital with Memosens technology Cell constant k = 1 cm -1 Application Measurements in media of medium and high conductivities: Medium separation in medium conductivities (milk/water) Medium separation in high conductivities (alkaline solution/water) Drinking water treatment Wastewater treatment The cell constant of the sensor is k = 1 cm -1. The measuring range reaches from 10 μs/cm to 20 ms/cm. Sensors with a temperature sensor are used together with conductivity transmitters equipped with automatic temperature compensation: Liquiline CM42 Mycom CLM153 Liquisys CLM223/253 For measurement of resistivity, MΩ cm measuring ranges are available in the menus of these transmitters. Your benefits Various designs guarantee optimum adaptation to the process conditions and methods of installation Installation in pipes or flow chambers Compact design Available with plug-in head or fixed cable High chemical, thermal and mechanical stability IP 65 (with four-pole plug-in head) / IP 67 (with fixed cable) / IP 68 (with Memosens plug-in head) Quality certificate with statement of the individual cell constant Further benefits offered by Memosens technology Maximum process safety through contactless inductive signal transmission Data safety through digital data transmission Easy handling thanks to storage of sensor-specific data in the sensor Predictive maintenance possible thanks to registration of sensor load data in the sensor TI085C/07/EN/04.10 71109189

Function and system design Measuring principle Conductive measurement of conductivity AC U I The conductivity of liquids is measured with the following measurement setup: Two electrodes are immersed in the medium. An AC voltage is applied to these electrodes which generates a current in the medium. The electric resistance or its reciprocal value, the conductance G, is calculated according to Ohm s law. The specific conductivity κ is determined using the cell constant k that is dependent on the sensor geometry. Conductive measurement of conductivity AC Power supply I Current meter U Voltage meter a00034 General properties Important properties of CLS21D Electrodes The sensor has two coaxial electrodes made of graphite for a large measuring range. The graphite guarantees high chemical stability and low polarization effects. Temperature compensation A temperature sensor is integrated to measure the medium temperature. Durability The sensor is pressure-proof up to bar at 20 C (232 psi at 68 F). It can be applied with temperatures of up to 135 C at 2.5 bar (275 F at 36.3 psi). Maximum process safety The inductive and non-contacting measured value transmission of Memosens guarantees maximum process safety and offers the following benefits: All problems caused by moisture are eliminated. The plug-in connection is free from corrosion. Measured value distortion from moisture is not possible. The plug-in system can even be connected under water. The transmitter is galvanically decoupled from the medium. EMC safety is guaranteed by screening measures for the digital measured value transmission. Data safety through digital data transfer The Memosens technology digitalizes the measured values in the sensor and transfers them to the transmitter contactlessly and free from interference potential. The result: An automatic error message is generated if the sensor fails or the connection between sensor and transmitter is interrupted. The availability of the measuring point is dramatically increased by immediate error detection. 2 Endress+Hauser

Easy handling Sensors with Memosens technology have integrated electronics that allow for saving calibration data and further information such as total hours of operation and operating hours under extreme measuring conditions. When the sensor is connected, the calibration data are automatically transferred to the transmitter and used to calculate the current measured value. Storing the calibration data in the sensor allows for calibration and adjustment away from the measuring point. The result: Sensors can be calibrated unter optimum external conditions in the measuring lab. Wind and weather do neither affect the calibration quality nor the operator. The measuring point availability is dramatically increased by the quick and easy replacement of precalibrated sensors. Maintenance intervals can be defined based on all stored sensor load and calibration data and predictive maintenance is possible. The sensor history can be documented on external data carriers and evaluation programs at any time. Thus, the current application of the sensors can be made to depend on their previous history. Communication with the transmitter Always connect digital sensors to a transmitter with Memosens technology. Data transmission to a transmitter for analog sensors is not possible. Data storage of CLS21D Measuring system Digital sensors are able to store the following system data in the sensor: Manufacturing data Serial number Order code Date of manufacture Calibration data Calibration date Cell constant Change in cell constant Number of calibrations Serial number of the transmitter used for the last calibration Application data Temperature application range Conductivity application range Date of first commissioning Maximum temperature value Operating hours at high temperatures A complete measuring system comprises: a CLS21 or CLS21D conductivity sensor a transmitter, e.g. Liquiline CM42 a measuring cable, e.g. CYK71 or CYK10 Memosens data cable 1 3 2 Measuring system example 1 Liquiline CM42 transmitter 2 CYK10 Memosens data cable 3 Condumax CLS21D sensor a0003417 Endress+Hauser 3

GN/YE } Input Measured values Cell constant k Measuring ranges Conductivity Temperature k = 1 cm 1 nominal Conductivity measurement (referred to water at 25 C / 77 F) 10 μs/cm to 20 ms/cm in the following temperature range: CLS21: -20 to 135 C (-4 to 275 F) CLS21D: -20 to 100 C (-4 to 212 F) (spec. measuring accuracy up to 100 C (212 F)) Temperature measurement CLS21: - 20 to 135 C (-4 to 275 F) CLS21D: - 20 to 100 C (-4 to 212 F) (spec. measuring accuracy up to 100 C (212 F)) Temperature sensor Cable specification CLS21: Pt 100 CLS21D: NTC CLS21 CLS21 is connected to the measuring transmitter using the special measuring cable CYK71 or CYK71-Ex or the fixed cable. Cable GY Coax BK Coax inner Sensor plug ) 2 Measuring electrode Measuring electrode Outer shield (see wiring diagram of transmitter) CYK71/CYK71-Ex or fixed cable GN WH YE BN n.c. } 3 1 Pt 100 a0003424-en CLS21D CLS21D is connected to the transmitter using the Memosens data cable CYK10. Special measuring cable CYK10 a0003350 Performance characteristics Measured error Each individual sensor is factory measured in a solution of approx. 5 ms/cm on a reference measuring system referred to NIST or DKD. The accurate cell constant is entered in the supplied quality certificate. The maximum measured error in cell constant determination is 1.0 %. 4 Endress+Hauser

Installation Installation instructions The sensors are mounted directly via the process connection. Optionally, they can be installed in flow assemblies. Installation in the CLA751 flow assembly a0003418 Installation in the CLA752 flow assembly a0003422 For installation of sensors with G1 thread in tanks, the CLA111 immersion and process assembly is available (see Accessories). Dipfit CLA111, mounting versions A, B and D a0003419 Note! The measuring surfaces must be completely immersed in the medium during operation. Endress+Hauser 5

Environment Ingress protection CLS21 Fixed cable: IP 67 (i NEMA 6) Plug-in head: IP 65 (i NEMA 4X) CLS21D: IP 68 (i NEMA 6) Process Process temperature Process pressure -20 to +135 C @ 2.5 bar (-4 to +275 F @ 36.3 psi) bar @ 20 C (232 psi @ 68 F) Pressure/temperature load curve p [psi] p [bar] 250 232 200 12 150 100 8 50 4 36.3 2.5 0 0 135-20 0 30 60 90 120 150 4 20 68 275 60 100 140 180 220 260 300 Mechanical pressure-temperature stability of the sensor T [ C] T [ F] a0003425 Mechanical construction Design, dimensions CLS21 1 1 2 2 3 4 3 Fixed cable version with NPT 1" thread 1 Fixed cable 2 NPT 1" thread 3 Sensor shaft a0003426 Connector version with 2" clamp 1 Four-pole connector 2 Pg 9 cable gland 3 2" clamp 4 Sensor shaft a0003434 6 Endress+Hauser

NPT 1" AF 35 NPT 1" (0.94) 61 (2.40) 14 (0.55) 113 (4.45) 157 (6.18) a0003427 Dimensions of fixed-cable version with NPT 1" thread 144 (5.67) 113 (4.45) 15 (0.59) 61 (2.40) Ø 34 (1.34) Ø64 (Ø 2.52) Dimensions of fixed-cable version with 2" clamp a0003428 144 (5.67) 61 (2.40) 54 (2.13) 10 (0.39) 5 (0.2) Ø 34 (1.34) Ø 47 (1.85) Ø55 (Ø 2.17) Dimensions of fixed-cable version with SMS thread a0007560 Endress+Hauser 7

151 (5.94) 79 (3.11) 36 (1.42) 21 (0.83) 36 (1.42) 18 (0.71) Ø 44 (1.73) G1 151 (5.94) 61 (2.40) 54 (2.13) 36 (1.42) 15 (0.59) Ø 34 (1.34) Ø64 (Ø 2.52) Dimensions of plug-in head version with G 1 thread a0003429 Dimensions of plug-in head version with 2" clamp a0003431 151 (5.94) 61 (2.40) 54 (2.13) 36 (1.42) 10 (0.39) Ø 34 (1.34) DN 25/DN 40 151 (5.94) 61 (2.40) 54 (2.13) 36 (1.42) 10 (0.39) 5 (0.2) Ø 34 (1.34) Ø 47 (1.85) Ø55 (Ø 2.17) Dimensions of plug-in head version with dairy fitting a0003432 a0003450 Dimensions of plug-in head version with SMS thread 8 Endress+Hauser

Design, dimensions CLS21D 1 2 3 186 (7.32) Ø 44 (1.73) 18 (0.71) 79 (3.11) G1 Version with G 1 thread 1 Memosens plug-in head 2 G 1 thread 3 Sensor shaft a0007502 Dimensions of version with G 1 thread a0007506 186 (7.32) 61 (2.40) 15 (0.59) Ø 44 (1.73) Ø 64 (Ø 2.52) 186 (7.32) 61 (2.40) 10 (0.39) Ø 44 (1.73) DN 25 Dimensions of version with 2" clamp a0007503 Dimensions of version with dairy fitting a0007505 Weight Materials Depending on version, approx. 0.3 kg / 0.7 lb. Electrodes: graphite Sensor shaft: polyethersulfone (PES-GF20) Thermal conductivity socket for temperature sensor: titanium 3.7035 Endress+Hauser 9

Process connections CLS21: Fixed-cable version: Thread NPT 1" Clamp 2" acc. to ISO 2852 SMS DN 38 (1½") Plug-in head version: Thread G 1 Clamp 2" acc. to ISO 2852 SMS DN 38 (1½") Dairy fitting DN 25 or DN 40 acc. to DIN 11851 CLS21D: Thread G 1 Thread NPT 1" Clamp 2" acc. to ISO 2852 Dairy fitting DN 25 acc. to DIN 11851 Note! Clamp connection: Sensors with clamp connections can be fixed using sheet metal brackets or solid brackets. Sheet metal brackets have a lower dimensional stability, uneven bearing surfaces causing point loads and sometimes sharp edges that can damage the clamp. We strongly recommend to always use solid brackets because of their higher dimensional stability. Solid brackets may be applied over the total pressure-temperature range (see temperature-pressure load curve). Certificates and approvals Ex approval Quality certificate ATEX II 1G Ex ia IIC T3 / T4 / T6 NEPSI Ex ia IIC T3 / T4 / T6 (CLS21D) FM/CSA IS/NI CL I Div. 1 & 2 GP A - D in combination with the Liquiline CM42 and Mycom CLM153 transmitters (CLS21) For CLS21D-***V: ATEX/NEPSI II 3G Ex nl IIC T3 / T4 / T6 for the use in Zone 2 with transmitter Liquiline CM42-KV*** for all product versions listed in the product structure (see Ordering Information) Note! Ex versions of digital sensors with Memosens technology are indicated by an orange-red ring in the plug-in head (not valid for versions CLS**D-***V). With statement of the individual cell constant 10 Endress+Hauser

Ordering information Product structure Condumax CLS21 Measuring range and cell constant C Measuring range: 10.0 μs... 20 ms/cm (k = 1) Process connection and materials 1E 1N 2A 2B 2C 3B Thread G 1, PES (plug-in head version only) Thread NPT 1", PES (fixed-cable version only) Dairy fitting DN 25, DIN 11851, PES (plug-in head version only) Dairy fitting DN 40, DIN 11851, PES (plug-in head version only) Process connection SMS DN 38, PES Clamp 2", PES Measuring cable connection 2 with 5 m /.41 ft fixed cable 3 with 10 m / 32.81 ft fixed cable 4 four-pole DIN connector with Pg 9, DIN 43650-A Temperature sensor A Integrated Pt 100 temperature sensor D No temperature sensor CLS21- complete order code Product structure Condumax CLS21D Measuring range and cell constant C Measuring range: 10.0 μs to 20 ms/cm (k = 1) L PWIS-free for measuring range 10.0 μs/cm to 20 ms/cm (k = 1) Process connection and materials 1E Thread G 1, PES 1N Thread NPT 1", PES 2A Dairy fitting DN 25, DIN 11851, PES 3B Clamp 2", PES Approval G ATEX/NEPSI II 1G Ex ia IIC T3/T4/T6 O FM/CSA IS/NI Cl I Div. 1 & 2 GP A - D V ATEX/NEPSI II 3G Ex nl IIC T3/T4/T6 1 Non-hazardous areas CLS21D- complete order code Endress+Hauser 11

Accessories Assemblies Dipfit CLA111 immersion and process assembly For open and closed tanks with DN 100 flange, for ordering information, see Technical Information Dipfit CLA111 (TI135C/07/en) A B D x + 155 (6.10) x = 1000, 2000, 500... 3000 (39.37, 78.74, 19.69... 118.11) y 155 (6.10) Ø151 (5.94) Ø194/ (7.64) Ø220/ (8.66) Ø63 (2.48) Ø76 (2.99) Ø60 (2.36) Dipfit CLA111, DN 100 flange or suspension bracket, mounting versions A, B and D 1000 (39.37) 205 (8.07) 80 (3.15) Ø84 (3.31) a0003435 CLA751 flow assembly 0 (6.30) Ø50 (1.97) G1 Ø 20 (0.79) 120 (4.72) G1 For installation of conductivity sensors with G 1 thread. Inlet (bottom) and outlet (lateral) DN 20 with union nuts G 1. Stainless steel 1.4571 (AISI 3Ti) Max. temperature: 0 C (320 F) Max. pressure: 12 bar (174 psi) Order no.: 50004201 CLA751 flow assembly G1 a0003436 12 Endress+Hauser

CLA752 flow assembly 0 (6.30) G½ G1 G½ For installation of conductivity sensors with G1thread Inlet (lateral) and outlet (lateral) DN 20 with G ½ internal thread Polypropylene (PP) Max. temperature: 90 C (194 F) Max. pressure: 6 bar (87 psi) Order no.: 50033772 mm / inch Ø 80 (3.15) CLA752 flow assembly a0003437 Connection Measuring cables CYK71 measuring cable Non-terminated cable for the connection of sensors (e.g. conductivity sensors) or the extension of sensor cables Sold by the meter, order numbers: non-ex version, black: 50085333 Ex version, blue: 515066 CYK10 Memosens data cable For digital sensors with Memosens technology Ordering according to product structure, see below Certificates A Standard, non-ex G ATEX II 1G Ex ia IIC T6/T4/T3, FM/CSA IS/NI Cl I DIV 1&2 GP A-D L LABS free, non-ex O FM IS/NI Cl I DIV 1&2 GP A-D S CSA IS/NI Cl I DIV 1&2 GP A-D T TIIS V ATEX/NEPSI II 3G Ex nl IIC Cable length 03 Cable length: 3 m (9.8 ft) 05 Cable length: 5 m ( ft) 10 Cable length: 10 m (33 ft) 15 Cable length: 15 m (49 ft) 20 Cable length: 20 m (66 ft) 25 Cable length: 25 m (82 ft) 88... m length 89... ft length Ready-made 1 Wire terminals 2 M12 plug CYK10- complete order code CYK81 measuring cable Non-terminated measuring cable for extension of sensor cables of e.g. Memosens sensors, CUS31/CUS41 2 wires, twisted pair with shield and PVC-sheath (2x2x 0.5 mm 2 + shield) Sold by the meter, order no.: 51502543 Endress+Hauser 13

Junction boxes Junction box VBM For cable extension 10 terminals Cable entries: 2 x Pg 13.5 or 2 x NPT ½" Material: aluminum Ingress protection: IP 65 (i NEMA 4X) Order numbers: cable entries Pg 13.5: 50003987 cable entries NPT ½": 51500177 Junction box VBM-Ex For cable extension in hazardous areas 10 terminals (blue) Cable entries: 2 x Pg 13.5 Material: aluminum Ingress protection: IP 65 (i NEMA 4X) Order no.: 50003991 Junction box RM For cable extension (e.g. for Memosens sensors) 5 terminals Cable entries: 2 x Pg 13.5 Material: PC Ingress protection: IP 65 Order no.: 51500832 Calibration solutions Transmitters Calibration solutions Precision solutions referred to SRM (Standard Reference Material) of NIST for qualified calibration of conductivity measuring systems according to ISO, with temperature table, CLY11-A 74 μs/cm (reference temperature 25 C (77 F)), 500 ml (.9 fl.oz); order no. 50081902 CLY11-B 149.6 μs/cm (reference temperature 25 C (77 F)), 500 ml (.9 fl.oz); order no. 50081903 CLY11-C 1.406 ms/cm (reference temperature 25 C (77 F)), 500 ml (.9 fl.oz); order no. 50081904 CLY11-D 12.64 ms/cm (reference temperature 25 C (77 F)), 500 ml (.9 fl.oz); order no. 50081905 For further information on calibration solutions see Technical Information TI2C/07/en. Liquiline CM42 (for analog conductivity sensors and digital conductivity sensors with Memosens technology) Modular two-wire transmitter for Ex and non-ex areas Hart, PROFIBUS or FOUNDATION Fieldbus available Ordering acc. to product structure, see Technical Information (TI381C/07/en) Liquisys CLM223/253 (for analog conductivity sensors) Transmitter for conductivity, field or panel-mounted housing, Hart or PROFIBUS available Ordering acc. to product structure, see Technical Information (TI193C/07/en) Mycom CLM153 (for analog conductivity sensors) Transmitter for conductivity, one or two channel version, Ex or Non-Ex, Hart or PROFIBUS available Ordering acc. to product structure, see Technical Information (TI234C/07/en) 14 Endress+Hauser

Endress+Hauser 15

Instruments International Endress+Hauser Instruments International AG Kaegenstrasse 2 4153 Reinach Switzerland Tel.+41 61 715 81 00 Fax+41 61 715 25 00 www.endress.com info@ii.endress.com TI085C/07/EN/04.10 FM+SGML 6.0 / ProMoDo / Printed in Germany / DT 71109189