Electric Grid Modernization Enabled by SiC Device based Solid State Transformers and Innovations in Medium Frequency Magnetics

Similar documents
2.8 Gen4 Medium Voltage SST Development

An Isolated DC-AC Converter Module Integrating Renewable Energy Source and Energy Storage for Cascaded Inverter

VIENNA Rectifier & Beyond...

Design and Implementation of Closed Loop LCL-T Resonant DC-to- DC Converter Using Low Cost Embedded Controller

Solid State Transformers (SST)

Practical Design Considerations for MV LCL Filter Under High dv/dt Conditions Considering the Effects of Parasitic Elements

The Next Steps in the Educa2on and Research on Wide Band Gap (WBG) Semiconductors Based Power Electronics

Generating Isolated Outputs in a Multilevel Modular Capacitor Clamped DC-DC Converter (MMCCC) for Hybrid Electric and Fuel Cell Vehicles

ACTIVE POWER ELECTRONIC TRANSFORMER A STANDARD BUILDING BLOCK FOR SMART GRID

A Power Electronics based Transformer design and its Optimization to reduce the losses

INVESTIGATION OF GATE DRIVERS FOR SNUBBERLESS OVERVOLTAGE SUPPRESSION OF POWER IGBTS

Converters Theme Andrew Forsyth

Gen: III. Gen: II - SRC. Gen: II - DAB. Gen: I. Y9.ET3: Robust Gen-III SST Development. Li Wang (PhD), Qianlai Zhu (PhD)

HIGH RELIABILITY AND EFFICIENCY OF GRID-CONNECTED PHOTOVOLTAIC SYSTEMS USING SINGLE-PHASETRANSFORMERLESS INVERTER. Abstract

Multiple PR Current Regulator based Dead-time Effects Compensation for Grid-forming Single-Phase Inverter

D-UPFC Application as the Series Power Device in the Massive Roof-top PVs and Domestic Loads

A COMPARITIVE STUDY OF THREE LEVEL INVERTER USING VARIOUS TOPOLOGIES

Micro-controller Based Three-phase Voltage Source Inverter for Alternative Energy Source. Abstract

High Efficiency Single Phase Transformer less PV Multilevel Inverter

Modified Multilevel Inverter Topology for Driving a Single Phase Induction Motor

SIMULATION AND EVALUATION OF A PHASE SYNCHRONOUS INVERTER FOR MICRO-GRID SYSTEM

Design of Five-Level Bidirectional Hybrid Inverter for High-Power Applications

Design and implementation of a LLC-ZCS Converter for Hybrid/Electric Vehicles

SHUNT ACTIVE POWER FILTER

Scientific Journal Impact Factor: (ISRA), Impact Factor: 1.852

Simulation and Comparision of Back To Back System using Bidirectional Isolated DC-DC Converter with Active Energy Storage

A Dual Half-bridge Resonant DC-DC Converter for Bi-directional Power Conversion

To Study The MATLAB Simulation Of A Single Phase STATCOM And Transmission Line

An Intelligent Bidirectional Solid State Transformer with Bidirectional Power Flow for Smart Grid Application

A Highly Versatile Laboratory Setup for Teaching Basics of Power Electronics in Industry Related Form

Designing High density Power Solutions with GaN Created by: Masoud Beheshti Presented by: Xaver Arbinger

Design of a Dual Active Bridge DC-DC Converter for Photovoltaic System Application. M.T. Tsai, C.L. Chu, Y.Z. Yang and D. R Wu

Feed-Forward System Control for Solid- State Transformer in DFIG

Recent Approaches to Develop High Frequency Power Converters

Improvement of Light Load Efficiency for Buck- Boost DC-DC converter with ZVS using Switched Auxiliary Inductors

Power of GaN. Enabling designers to create smaller, more efficient and higher-performing AC/DC power supplies

Control of Power Converters for Distributed Generation

D-Σ Digital Control for Improving Stability Margin under High Line Impedance

M.Tech in Industrial Electronics, SJCE, Mysore, 2 Associate Professor, Dept. of ECE, SJCE, Mysore

DUAL BRIDGE LLC RESONANT CONVERTER WITH FREQUENCY ADAPTIVE PHASE-SHIFT MODULATION CONTROL FOR WIDE VOLTAGE GAIN RANGE

CHAPTER 4 MODIFIED H- BRIDGE MULTILEVEL INVERTER USING MPD-SPWM TECHNIQUE

2015 International Future Energy Challenge Topic B: Battery Energy Storage with an Inverter That Mimics Synchronous Generators. Qualification Report

Switches And Antiparallel Diodes

IJSRD - International Journal for Scientific Research & Development Vol. 4, Issue 01, 2016 ISSN (online):

Implementation and Design of Advanced DC/AC Inverter for Renewable Energy

CHAPTER 2 A SERIES PARALLEL RESONANT CONVERTER WITH OPEN LOOP CONTROL

Voltage Fed DC-DC Converters with Voltage Doubler

Single Phase Single Stage Power Factor Correction Converter with Phase Shift PWM Technique

Voltage Balancing Control of Improved ZVS FBTL Converter for WECS

Split-winding type three limb core structured HF transformer for integrating PV and energy storage(es)

Design of Single Phase Pure Sine Wave Inverter for Photovoltaic Application

A Novel Cascaded Multilevel Inverter Using A Single DC Source

Energy System Protection for Grid Resilience. Xianyong Feng, PhD, PE Center for Electromechanics The University of Texas at Austin October 31, 2017

IMPROVED TRANSFORMERLESS INVERTER WITH COMMON-MODE LEAKAGE CURRENT ELIMINATION FOR A PHOTOVOLTAIC GRID-CONNECTED POWER SYSTEM

Analysis of Utility Interactive Photovoltaic Generation System using a Single Power Static Inverter

POWER- SWITCHING CONVERTERS Medium and High Power

Joe Warner, Electric Power Industry Conference (EPIC), November 15, 2016 Advances in Grid Equipment Transmission Shunt Compensation

PULSE FREQUENCY MODULATION ZCS FLYBACK CONVERTER IN INVERTER APPLICATIONS

Single Phase Induction Motor Drive using Modified SEPIC Converter and Three Phase Inverter

Impact of Basal Plane Dislocations and Ruggedness of 10 kv 4H-SiC Transistors

High Voltage-Boosting Converter with Improved Transfer Ratio

CHAPTER 4 MULTI-LEVEL INVERTER BASED DVR SYSTEM

Experimental Analysis of Single-Phase Non- Transformer Photovoltaic Inverter with Optimum Efficiency

Available online at ScienceDirect. Procedia Technology 21 (2015 ) SMART GRID Technologies, August 6-8, 2015

Power Factor Corrected Single Stage AC-DC Full Bridge Resonant Converter

Grid Connected Photovoltaic Micro Inverter System using Repetitive Current Control and MPPT for Full and Half Bridge Converters

Published by: PIONEER RESEARCH & DEVELOPMENT GROUP(

Matlab /Simlink based closed Loop Control of Bi-Directional DC - DC Converter

Grid-Connected Boost-Half-Bridge Photovoltaic Micro inverter System Using Repetitive Current Control and Maximum Power Point Tracking

Highly Efficient step-up Boost-Flyback Coupled Magnetic Integrated Converter for Photovoltaic Energy

ECE1750, Spring dc-ac power conversion

PC Krause and Associates, Inc.

DSP-Based Simple Technique for Synchronization of 3 phase Alternators with Active and Reactive Power Load Sharing

Sepic Topology Based High Step-Up Step down Soft Switching Bidirectional DC-DC Converter for Energy Storage Applications

Shattock, Nicholas (2014) High frequency-link cycloconverters for medium voltage grid connection. PhD thesis, University of Nottingham.

POWER ISIPO 29 ISIPO 27

PE Electrical Machine / Power Electronics. Power Electronics Training System. ufeatures. } List of Experiments

Experimental Verification of High Frequency Link DC-AC Converter using Pulse Density Modulation at Secondary Matrix Converter.

A Research In AC-AC/DC-DC DAB Based Solid State Transformers

MegaCube. G. Ortiz, J. Biela, J.W. Kolar. Swiss Federal Institute of Technology (ETH) Zurich Power Electronic Systems Laboratory

Implementation Of Bl-Luo Converter Using FPGA

B.Tech Academic Projects EEE (Simulation)

Study of a 3kW High-Efficient Wide-Bandgap DC- DC Power Converter for Solar Power Integration in 400V DC Distribution Networks

Chapter 3 : Closed Loop Current Mode DC\DC Boost Converter

Implementation of high-power Bidirectional dc-dc Converter for Aerospace Applications

EFFICIENT DUAL AXIS SOLAR TRACKER WITH H-BRIDGE INVERTER

Vienna Rectifier Fed BLDC Motor

Power electronic converters in power systems. SINTEF Energy Research

proton beam onto the screen. The design specifications are listed in Table 1.

SiC MOSFETs Based Split Output Half Bridge Inverter: Current Commutation Mechanism and Efficiency Analysis

CHAPTER 7 HARDWARE IMPLEMENTATION

HIGH EFFICIENCY TRANSFORMER LESS INVERTER FOR SINGLE-PHASE PHOTOVOLTAIC SYSTEMS USING SWITCHING CONVERTER

Cascaded H-Bridge Five Level Inverter for Harmonics Mitigation and Reactive Power Control

INTERNATIONAL JOURNAL OF PURE AND APPLIED RESEARCH IN ENGINEERING AND TECHNOLOGY

PERFORMANCE ANALYSIS OF SOLAR POWER GENERATION SYSTEM WITH A SEVEN-LEVEL INVERTER SUDHEER KUMAR Y, PG STUDENT CHANDRA KIRAN S, ASSISTANT PROFESSOR

High Voltage DC Transmission 2

GaN in Practical Applications

HYBRID ACTIVE FILTER WITH VARIABLE CONDUCTANCE FOR HARMONIC RESONANCE SUPPRESSION USING ANN

SINGLE PHASE MULTI STRING FIVE LEVEL INVERTER FOR DISTRIBUTED ENERGY SOURCES

A New 98% Soft-Switching Full-Bridge DC-DC Converter based on Secondary-Side LC Resonant Principle for PV Generation Systems

Transcription:

1/31 Electric Grid Modernization Enabled by SiC Device based Solid State Transformers and Innovations in Medium Frequency Magnetics Dr. Subhashish Bhattacharya Department of Electrical and Computer Engineering North Carolina State University Raleigh, NC FREEDM Annual Meeting April 11 th, 2019

2/31 Contents Introduction Solid state transformers (SST) as an enabler for the new grid SST examples and Design challenges of SSTs Magnetics requirements for MV high frequency transformers (HFT) for SSTs Conclusion

Introduction 3/31 Traditional Power System Modern Power System Replacing 60 Hz Transformer Complex - large no. of variables Limited scope for control Non-linear loads Harmonics Lagging reactive power Penetration of renewables Power electronic converters dc-ac ac-ac Increased controllability Energy Control Center Solid State Transformer Power Electronic Transformer Intelligent Transformer

Medium Voltage DC Microgrids 4/31 DC Micro-grid Application DC micro-grid interface with DABs Ring type DC micro-grid

Solid State Transformer Technology Conventional Distribution Transformers Bulky in size and weight Unidirectional power flow No solution for improving power quality Improper voltage regulation Lesser flexibility in control Cannot connect asynchronous networks Complex integration of renewables and DESD 5/31 60 Hz Distribution Transformer Solid State Transformers (SST) Smaller in size and light in weight Bidirectional power flow Improves power quality UPF operation Harmonic elimination Better voltage regulation Reactive power compensation Flexibility in control Renewable integration ac and dc links SiC devices Improving efficiency Lesser cooling requirements FREEDM SST Work done at FREEDM Systems Center on Single Phase SSTs using HV SiC MOSFETs

Conventional Distribution Transformers 6/31 1MVA Transformer 1MVA Transformer Transformer Core Physical Dimensions 1MVA, 15kV:480Y/277V Frequency Mass lb (kg) Volume f 3 (m 3 ) 60 Hz 8,160 (3,700) 169 (4.8) 400 Hz 992 (450) 125 (3.54) 1 khz 790 (358) 101 (2.86) 20 khz 120 (54.4) 0.5 (0.14) 50 khz 100 (45.4) 0.5 (0.14)

7/31 SST Topologies Enabled by SiC HV Devices: 15kV IGBTs and MOSFETs, 10kV MOSFETs

15 kv SiC IGBT & 15 kv SiC MOSFET Modules JBS SiC Diodes 15kV SiC IGBT 15 kv SiC IGBT (single chip) co-pack module 15 kv SiC MOSFET(Two chip) co-pack module

10kV SiC MOSFET Co-pack Modules Single 10kV SiC MOSFET Module

7.2 kv AC L SH1 SH2 SH5 SH6 S1 S2 High Frequency Transformer 3.8kV + 400V + DC - DC - 10/31 Solid State Transformer: Gen-I and Gen-II AC/DC Rectifier DC/DC Converter DC/AC Inverter 120V / 240V AC Ls Port 1 Cs SH3 SH4 SH7 SH8 S3 S4 Ls Cs Port 2 High voltage H-Bridge High Voltage H-Bridge Low Voltage H-Bridge AC-DC 3.8kV + DC - 400V + DC - DC-DC DC-AC L 5.5 kv High Freq. Trans 7.2 kv ac 400 V 120V ac 5.5 kv 3.8kV + DC - + - LV H-Bridge Low voltage stage LV H-Bridge HV 3-Level H-Bridge HV 3-Level H-Bridge High voltage stage Gen-1 SST High Voltage Side Low Voltage Side DC-bus 3800 V 400 V Current at maximal load 2.66 A 25.27A Power 7 kw Turns ratio 9.5:1 Switching frequency 3kHz, 20kHz Phase Shift pi/ 6 ~ pi/ 4 Gen-2 SST High Voltage Side Low Voltage Side DC-bus 3*3800 V 400 V Current at maximal load 3*2.66 A 25.27A Power 3*7 kw Turns ratio 9.5:1 Switching frequency 3kHz, 20kHz Phase Shift pi/ 6 ~ pi/ 4

11/31 Transformerless Intelligent Power Substation (TIPS) 3-Phase SST - 13.8 kv to 480 V TIPS Power Flow Diagram SiC based solid-state alternative to 60 Hz transformer Advantages Controllability, Bi-directional Power Flow, VAR Compensation, Small Size and Light Weight, Lower Cooling Requirement, and Integration of Renewable Energy Sources/Storage Elements

TIPS Converter Laboratory Set-up 12/31 1200 V SiC MOSFET Based Low Voltage Side Converter Single Phase High Frequency Transformer

TIPS Grid Connected Converter - Experimental 13/31 Demonstration FEC side waveforms for 4.16 kv MV ac grid tie operation with 8 kv MV dc bus and 9.6 kw load Peak current ~ 2.5 A FEC grid currents and R-phase pole-voltage RY-grid voltage and R-phase grid current Ripple in the MV grid voltage is due to converter PWM voltage across the 60 Hz transformer leakage inductance (30 mh) Peak current shown is including the switching ripple

TIPS Grid Connected Converter - Experimental 14/31 Demonstration DAB side waveforms at 8 kv MV dc bus voltage, 480 V LV dc bus voltage and 9.6 kw All waveforms captured at the HF transformer terminals Ripple in the DAB currents is due to the HF transformer parasitics

15/31 Solid State Transformers (SST) for Mobile Utility Support Equipment (MUSE) 3-phase SST structure Connects 4.16 kv, 60 Hz grid to 480 V, 60 Hz grid with currently at 8 kv high voltage DC link and 800 V low voltage DC link High Voltage side converters are 3-Φ 2-level converters, Low voltage side converter is 2-level converter High frequency transformer forms Y-Δ connections for near sinusoidal current.

16/31 Non-Synchronous MV Microgrid Interconnection Nonsynchronous interconnection approach reduces the cost and time Always in islanding mode due to the DC link, mitigates the AC fault propagation Galvanic isolation by step-down transformer rated at 5MVA 27/3.3kV, 60Hz [2] High voltage silicon IGBTs in power stages Standard 6MVA AC-DC-AC module Package size of a shipping container Energy flow from multiple sources without requiring utility permits Modular approach allows new energy to be added in future [1] Pareto Energy, Microgrids for data centers, Available online 2018 http://www.paretoenergy.com/whitepaperfiles/presentationparetoenergymicrogridsfordatacenterswebpageversion.pdf

17/31 Medium Voltage Asynchronous Microgrid Connector 13.8 kv asynchronous grid, 50Hz or 60Hz; 100kVA bidirectional power flow 3L NPC pole realized by series connected Gen3 10kV, 15A SiC MOSFETs Intrinsic body diode as freewheeling diode, and 10kV, 15A SiC JBS diode as the clamping diodes 24kV DC link, 10kHz switching frequency in FEC and DAB [3] A. Kumar, S. Parashar, N. Kolli and S. Bhattacharya, "Asynchronous Microgrid Power Conditioning System Enabled by Series Connection of Gen-3 SiC 10 kv MOSFETs," 2018 IEEE 6th Workshop on Wide Bandgap Power Devices and Applications (WiPDA), Atlanta, GA, 2018, pp. 60-67.

AGC Testing Results 18/31 Step 1: Selection of the snubber resistor and capacitor values. Rd=4.7Ω Cd=1nF V dc total 2kV/ div Rs= 1M Ω V gs 20V/ div I ds 2A/ div V ds2 2kV/ div V ds1 2kV/ div Double pulse test with the series connected MOSFETs. Vdc: 12kV, Vgs=20V/-5V.

AGC Testing Results 19/31 Step 4:Three level converter test setup (Single phase with series connection) Schematic of the Single phase series connection Experimental setup for series connected single phase leg

AGC Testing Results 20/31 Step 2: Half Bridge testing of the Series Connected MOSFETs. Turn off Test Set up Turn on 20 Vds1= 1.27kV, Vds2= 1.292kV, t_on = 800ns, t_off = 300ns

21/31 Experimental Results 1000V DC bus voltage, 2.5A peak current, 60Hz fundamental, 10kHz switching frequency V AN I load V AN (pole-to-dc midpoint voltage): 400V/div, I load (load current): 2A/div; Time: 5ms/div

High Power Medium Frequency Magnetics for Power Electronics Applications

Sunlamp Architecture 23/31 Conventional MV grid connection using low frequency transformer. Proposed MV grid connection using isolated power electronic converters and simpler dc-ac converter structure. Contributions of the Sunlamp Project: Overall architecture selection and dc-dc and dc-ac converter designs. Combining PV and ES on the DC Side with a 3-winding transformer for new topologies and system benefits. System level Integration simulation and experimental demonstration Advanced magnetic core and high frequency transformer fabrication, design, and testing.

Triple Active Bridge (TAB) and Magnetic 24/31 Designs Ipv (20A/div) Vpv (1kV/div) Vpv (1kV/div) Ipv (20A/div) V3 (1kV/div) V3 (1kV/div) I3 (10A/div) I3 (10A/div) Ies (10A/div) Ies (10A/div) Ves (1kV/div) Ves (1kV/div) Highlights of the Sunlamp Project 10kW, 20kW and 50kW TAB converter demonstrated at NC State University. Prototypes designed based Upon 3-Limb and Single Core, 3-Winding Transformers. HF Transformer Design, Build, and Test. I pv PV 1200V SiC Mosfet Converter V pvdc PWM V PV V 1a V 2a 1700V SiC Mosfet Converter V3 PWM V dc3 Controller A triple active bridge (TAB) integrating PV and an energy storage. V 1b V2b V ES 1200V SiC Mosfet Converter I 3 DC BUS PWM Vesdc I es ES Various inductor designs realized for the TAB. Various transformer designs realized for the TAB. Experimental results from a TAB under test.

25 System Efficiency at 100kHz 25/31 Efficiency variation with input power at 100kHz

Gen-II SST High Frequency Co-Axial Winding 26/31 (CWT) Transformer - Design & Test at 20kHz, 30kW 30cm*17cm*9cm DC-DC converter of the SST; 30kVA, 20 khz CWT test - Yellow (Vo) 5kV/div, pink (Vi) 200V/div, green (Imag) 20A/div; Heat distribution after 90 min operation

7 27/31 Fault-tolerancy Examples in Nature Bird flock or school of fish avoid predators by using multiple sensors (eyes) One animal can inform other animals by changing direction, forming a virtual single mass body Chance of survival for the species is much higher in the synchronization mode than living individually

Implementation of the Proposed Controller 28/31 A hardware test-bed has been developed to test the functionality of the system in real scenario It consists of 13 controllers (12 slave and one master) and 3 FPGAs which makes it capable to implement various architectures and gather data in the best format Analog inputs have been leveled to match the voltage rating of the controllers It is possible to use the controller with hardware in the loop (HIL) simulator and the experimental setup in the lab

29/31 Cascaded H-bridge (CHB) Converter (OPAL-RT CHIL Results)

Conclusion Electric Grid Modernization requires plug-n-play feature provided by SST for integration of renewables, energy storage Magnetics is the most important component of SST!!!!! Rich sandbox for research enabled by HV SiC devices Important to get students educated in SST and magnetics Efficient and reliable MV grid connected converters is key to enabled renewable energy power conversion systems Need to solve practical issues hence industry + academic + DoE Lab participation / collaboration is key 30/31

Acknowledgements 31/31 To all my past and present PhD, MS and UG research students and post-doctoral scholars Thank You!!! Questions Acknowledgements: FREEDM Systems Center, PowerAmerica ARPA-E, Navy, DOE and Industry Sponsors Dept. of ECE, NC State University