Evaluation Method of Magnetic Sensors Using the Calibrated Phantom for Magnetoencephalography

Similar documents
(12) Patent Application Publication (10) Pub. No.: US 2017/ A1

SQUID - Superconducting QUantum Interference Device. Introduction History Operation Applications

Eddy Current Nondestructive Evaluation Using SQUID Sensors

THE MFL TECHNIQUE FOR SURFACE FLAWS USING RESIDUAL MAGNETIZATION METHOD WITH THE MI (MAGNETO-IMPEDANCE) SENSOR

SQUID Basics. Dietmar Drung Physikalisch-Technische Bundesanstalt (PTB) Berlin, Germany

AFRL-RX-WP-TP

Magnetoencephalography and Auditory Neural Representations

BME 3113, Dept. of BME Lecture on Introduction to Biosignal Processing

Permeability Measurements of Very Thin Magnetic Film Using a Flexible Microstrip-Line-Type Probe

Multi-channel SQUID-based Ultra-Low Field Magnetic Resonance Imaging in Unshielded Environment

Simultaneous geomagnetic monitoring with multiple SQUIDs and fluxgate sensors across underground laboratories

from signals to sources asa-lab turnkey solution for ERP research

Design of magnetic field alarm powered by magnetic energy harvesting

ACOUSTIC AND ELECTROMAGNETIC EMISSION FROM CRACK CREATED IN ROCK SAMPLE UNDER DEFORMATION

SQUID Gradiometer for Biomagnetic Fields

Voltage Biased Superconducting Quantum Interference Device Bootstrap Circuit

1088 IEEE SENSORS JOURNAL, VOL. 11, NO. 4, APRIL 2011

rf SQUID Advanced Laboratory, Physics 407 University of Wisconsin Madison, Wisconsin 53706

Los Alamos. Low-Field Magnetic Resonance Imaging of. David M. Schmidt, Michelle A. Espy, P-21

SOPA version 2. Revised July SOPA project. September 21, Introduction 2. 2 Basic concept 3. 3 Capturing spatial audio 4

Leakage Flux Recovery Coil for Energy Harvesting Using Magnetoplated Wire

EMC TEST REPORT For MPP SOLAR INC Inverter/ Charger Model Number : PIP 4048HS

COOMET Pilot Comparison 473/RU-a/09: Comparison of hydrophone calibrations in the frequency range 250 Hz to 200 khz

S600X SQUID M AGNETOMETER. S600X - For better magnetic measurements. The Better Choice. AC and DC measurements.

Steam Generator Tubing Inspection

Measurement of SQUID noise levels for SuperCDMS SNOLAB detectors

Development and Applications of SQUIDs in Korea

Transmitter Identification Experimental Techniques and Results

EXTREME LOW FREQUENCY MAGNETIC IMAGING METHOD FOR DETECTION OF. Katsumi INOUE 2)

Control of Induction Thermal Plasmas by Coil Current Modulation in Arbitrary-waveform

Multicore Off-Diagonal Magnetoimpedance Sensors Utilising Amorphous Wires

EFFECT OF INTEGRATION ERROR ON PARTIAL DISCHARGE MEASUREMENTS ON CAST RESIN TRANSFORMERS. C. Ceretta, R. Gobbo, G. Pesavento

AC metrology. Resources and methods for learning about these subjects (list a few here, in preparation for your research):

Optical Magnetometer Employing Adaptive Noise Cancellation for Unshielded Magnetocardiography

CHAPTER 2 D-Q AXES FLUX MEASUREMENT IN SYNCHRONOUS MACHINES

Acoustic Transducer*

Eddy Current Nondestructive Evaluation Based on Fluxgate Magnetometry Umberto Principio Sponsored by: INFM

Spatial detection of ferromagnetic wires using GMR sensor and. based on shape induced anisotropy

NONLINEAR C-SCAN ACOUSTIC MICROSCOPE AND ITS APPLICATION TO CHARACTERIZATION OF DIFFUSION- BONDED INTERFACES OF DIFFERENT METALS

ACTIVE SHIELDING IN MEASUREMENTS OF DC NEAR BIOMAGNETIC FIELDS

Enhancement of Fault Current and Overvoltage by Active Type superconducting fault current limiter (SFCL) in Renewable Distributed Generation (DG)

Study on Analysis of Torque-Slip Characteristics of Axial Gap Induction Motor

Section 2. AC Circuits

Introduction to SQUIDs and their applications. ESAS Summer School Jari Penttilä Aivon Oy, Espoo, Finland

DESIGN, CONSTRUCTION, AND THE TESTING OF AN ELECTRIC MONOCHORD WITH A TWO-DIMENSIONAL MAGNETIC PICKUP. Michael Dickerson

MAGNEPROBE : A COMPUTERIZED PORTABLE SYSTEM FOR NON

Experiment 2: Transients and Oscillations in RLC Circuits

Phase-sensitive high-speed THz imaging

A STUDY ON NOISE REDUCTION OF AUDIO EQUIPMENT INDUCED BY VIBRATION --- EFFECT OF MAGNETISM ON POLYMERIC SOLUTION FILLED IN AN AUDIO-BASE ---

Bias reversal technique in SQUID Bootstrap Circuit (SBC) scheme

Page 2 A 42% B 50% C 84% D 100% (Total 1 mark)

Development of a Vibration Measurement Method for Cryocoolers

Rotating Coil Measurement Errors*

Equivalent Circuits for Repeater Antennas Used in Wireless Power Transfer via Magnetic Resonance Coupling

System Options. Magnetic Property Measurement System. AC Susceptibility. AC Susceptibility Specifications

A new capacitive read-out for EXPLORER and NAUTILUS

DEEP FLAW DETECTION WITH GIANT MAGNETORESISTIVE (GMR) BASED SELF-NULLING PROBE

Compact and Multifunction Controller for Parts Feeder

Observation of Remanent Vortices Attached to Rough Boundaries in Superfluid 4 He

HTS PARTIAL CORE TRANSFORMER- FAULT CURRENT LIMITER

DEVELOPMENT OF MINIATURE HYDROPHONE WITH HYDRO-THERMALLY SYNTHESIZED PZT POLY-CRYSTALLINE FILM

Vibration-Free Pulse Tube Cryocooler System for Gravitational Wave Detectors II - Cooling Performance and Vibration -

NONDISTRUCTIVE TESTING INSTRUMENT OF DISHED Nb SHEETS FOR SRF CAVITIES BASED ON SQUID TECHNOLOGY

Magnetic sensor signal analysis by means of the image processing technique

USE OF BASIC ELECTRONIC MEASURING INSTRUMENTS Part II, & ANALYSIS OF MEASUREMENT ERROR 1

Liquid sensor probe using reflecting SH-SAW delay line

Earthquake Resistance Test Specifications for Communications Equipment

Biomedical Research 2017; Special Issue: ISSN X

Adaptive Noise Canceller for Magnetocardiography

Experiment P52: Magnetic Field of a Solenoid (Magnetic Field Sensor, Power Amplifier)

The Development of a High Sensitive Micro Size Magnetic Sensor Named as GSR Sensor Excited by GHz Pulse Current

RECENT applications of high-speed magnetic tracking

arxiv:cond-mat/ v1 [cond-mat.mes-hall] 23 Mar 2001

Fabrication and application of a wireless inductance-capacitance coupling microsensor with electroplated high permeability material NiFe

Noise Suppression in Unshielded Magnetocardiography: Least-Mean Squared Algorithm versus Genetic Algorithm

Wide band pneumatic sound system for MEG

A Tactile Display using Ultrasound Linear Phased Array

Detection and Imaging of Internal Cracks by Tangential Magnetic Field Component Analysis using Low-Frequency Eddy Current Testing

Minimum Leakage Current for Dry Band Formation under Polluted Environment

LOW-FREQUENCY search coil magnetometers are

Nondestructive Detection of Local Material Thinning in Ferromagnetic Materials by Magnetic Adaptive Testing

Conductance switching in Ag 2 S devices fabricated by sulphurization

The next science run of the gravitational wave detector NAUTILUS

7 Telsa SQUID Magnetometer

PHYSICAL METHODS, INSTRUMENTS AND MEASUREMENTS Vol. IV - SQUIDs in Neuro-and Cardiomagnetism - Olli V. Lounasmaa, Heikki Seppä

Analysis of metallic ropes magnetisation during magneto-inductive testing

An EOG based Human Computer Interface System for Online Control. Carlos A. Vinhais, Fábio A. Santos, Joaquim F. Oliveira

Superconducting Gravity Gradiometers (SGGs)

Characteristics of point-focus Simultaneous Spatial and temporal Focusing (SSTF) as a two-photon excited fluorescence microscopy

Circularly Polarized Post-wall Waveguide Slotted Arrays

Test Report. Applicant ASUSTeK COMPUTER INC. 4F, No. 150, Li-Te Rd., Peitou, Taipei, Taiwan. Date of Receipt Jan. 28, Issued Date Mar.

32-channel Multi-Chip-Module The Cryogenic Readout System for Submillimeter/Terahertz Cameras

Design and Implementation of Self-Tuning Fuzzy-PID Controller for Process Liquid Level Control

Evaluation of Legibility

A Generalized noise study of solid-state nanopores at low frequencies

Title ZnO device and resistor in parallel IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY (2006), 16(2): 65.

ELECTRIC FIELD WAVEFORMS OF UPWARD LIGHTNING FORMING HOT SPOT IN WINTER IN JAPAN

HBM2006: MEG/EEG Brain mapping course MEG/EEG instrumentation and experiment design. Florence, June 11, 2006

MAGNETORESISTIVE EDDY-CURRENT SENSOR FOR DETECTING

6 Electromagnetic Field Distribution Measurements using an Optically Scanning Probe System

Transcription:

J. Magn. Soc. Jpn., 41, 7-74 (217) <Paper> Evaluation Method of Magnetic Sensors Using the Calibrated Phantom for Magnetoencephalography D. Oyama, Y. Adachi, and G. Uehara Applied Electronics Laboratory, Kanazawa Institute of Technology, Amaike 3, Kanazawa, Ishikawa 92-1331, Japan In recent years, many kinds of magnetic sensors have been developed for biomagnetic measurement, such as magnetocardiography (MCG) and magnetoencephalography (MEG). However, it is difficult to evaluate their performance using only actual MCG or MEG measurements. In this paper, we propose the use of the calibrated MEG phantom for quantitative evaluation of magnetic sensors and present the experimental method. We choose a magneto-impedance (MI) sensor as an example of the magnetic sensor to be evaluated. The magnetic field distribution near the phantom was measured using the and a signal source was localized with different averaging numbers and different signal source intensities. The results suggest that the MEG signal cannot be observed in the usual averaging time (i.e., ), even when the sensor is located near the head; 4. mm of source localization accuracy can be achieved with 4-times averaging if the sensor noise decreases to 1/1. The use of the calibrated phantom, instead of examination with human subjects, is effective for quantitative evaluation of the performance of magnetic sensors. Key words: magnetoencephalography, phantom, magneto-impedance sensor 1. Introduction Biomagnetic signal measurements, such as magnetoencephalography (MEG) and magnetocardiography (MCG) are utilized in clinical applications and neuroscience studies. The magnetic signals from the brain and heart are very weak; therefore, superconducting quantum interference device (SQUID) sensors have been used for practical MEG and MCG systems for which the sensitivity is less than 1 ft/hz 1/2. On the other hand, SQUID sensors must be cooled by liquid helium to maintain superconductivity. Helium-less MCG or MEG systems are important because of the cost and low availability of liquid helium. In recent years, the development of refrigerant-less or room-temperature magnetic sensors has advanced, with the aim of realizing new biomagnetic measurement systems. Some groups have succeeded in detecting the magnetic signal from the human heart or brain 1)-6), and practical applications are expected. However, the evaluation of such magnetic sensors is difficult with actual MCG or MEG measurement, because there is no guarantee of reproducibility or reliability of the signal sources. Objective evidence is important to prove the effectiveness of newly developed sensors. Additionally, quantitative evaluation is necessary for designing the biomagnetic measurement system using these sensors. Therefore, the authors propose the use of a phantom for the evaluation of the newly developed magnetic sensors. A phantom is an artificial object that imitates the human body. Quantitative evaluation can be achieved using phantom experiments instead of examination of a human subject. The authors have developed a new phantom and an associated calibration method designed for quantitative evaluation of MEG systems 7). This phantom was calibrated and its uncertainty was determined so as to ensure reproducibility and reliability. In this paper, an evaluation method for a room-temperature magnetic sensor using the calibrated phantom is introduced. As an example of the experimental evaluation with the phantom, we chose a magneto-impedance (MI) sensor that is a candidate for realizing a helium-less MEG system. The experimental setup is detailed in Section 2. The measured data are presented in Section 3. The feasibility of MEG signal detection by the is discussed in Section 4. 2. Method 2.1 Phantom One popular method to analyze the MEG data is to estimate a magnetic source in a human brain using the Sarvas formula 8). In the model of the Sarvas formula, the human brain and the source are a conductive sphere and a dipole, respectively. There are two types of phantoms: one is the wet phantom, composed of two electrodes installed in a sphere filled with saline, and the other is the dry phantom, composed of a triangular wire based on Ilmonieimi s suggestion 9). We have chosen the dry-type phantom because it is much easier to handle, maintain, and calibrate. Figure 1 shows the schematics of the phantom. Two individual isosceles triangles were wound around a quadrangular pyramidal bobbin. The isosceles triangular model has a 5-mm base and 65-mm height. Twenty-five bobbins were assembled inside a domed cover that imitates a human skull. The equivalent dipoles (ECDs) corresponding to fifty triangular 7

5 mm PHANTOM 65 mm q y R = 75 mm x z 1 mm 65 mm 75 mm Fig. 1 Configuration of the MEG phantom. schematic of an isosceles-triangular coil pair. photograph of the MEG phantom 7). y x z 76 mm Z Magnetic flux density [pt/hz 1/2 ] 1 sensing direction 1.1 1 1 Frequency [Hz] Fig. 2 Noise level of the recorded inside a magnetically shielded room. Fig. 3 Setup for experimental evaluation of the MI sensor using the phantom. Schematics of the experimental setup and photograph of the phantom and the. wires were estimated based on three-dimensional measurement of the paths and numerical calculations. The details of the phantom configuration and calibration are described in Ref. 7. 2.2 Sensor In this study, we used a commercially available MI sensor (MI-CB-1DH, Aichi Micro Intelligent Corporation). Figure 2 shows the magnetic noise spectrum recorded inside a magnetically shielded room (MSR). The noise level was approximately 1 pt/hz 1/2 at 1 Hz. The noise level of a SQUID sensor for an MEG system should be of femto-tesla order. Although the sensitivity of the is insufficient, the room-temperature sensor has the advantage of being placed at a closer position to the head. Improvement of the signal-to-noise ratio is expected because of the shorter distance between the sensor and the signal source. 2.3 Experimental setup Figure 3 shows the experimental setup and the photograph of the phantom and the. One triangular wire was chosen for the experiment and an electric was applied to it by a function generator. The waveform was a sinusoidal burst at a frequency of 11 Hz. The measurement was performed using different amplitudes I = 1 and A. The intensity of the ECD corresponding to an applied amplitude of 1 A was approximately 5 na m. This ECD intensity is similar to that estimated from the recorded data of human auditory evoked responses. To measure the magnetic field distribution near the phantom, the and the phantom were fixed on a three-axial stage and a rotation stage, respectively. The sensing direction of the was indicated by arrows in Fig. 3, therefore, the magnetic field normal to the phantom surface was detected by the. The total number of measuring points was 54; these 71

I = 1 A, Nave = 4 I = 1 A, Nave = I = 1 A, Nave = 8 I = 1 A, Nave = 12 I = 1 A, Nave = 16 I = A, Nave = 5 pt (h) I = A, Nave = 4 height z = 1mm rotation angle q = 1 degree 5 A 5 pt 15 15 1 5 5-5 -5-1 - -15-15 signal intensity in pt left : -, right : - Fig. 4 Measured waveforms - with different amplitudes (I) and averaging numbers (Nave), and the applied waveform (h). Fig. 5 Contour maps with different amplitudes (I) and averaging numbers (Nave). points were obtained by rotating the phantom (q =, ±4, ±12, ±2, ±28 ) and vertically shifting the (z = 2, 1,, 1, 2, 3 mm). The phantom and the were placed in an MSR while measurements were taken. The output signal of the was amplified ( ) and band-pass filtered (cut-off frequencies =.1 Hz and 5 Hz) before recording. The recording was performed by a 16-bit A/D converter (PCIe-6353, National Instruments). The sampling frequency was 2 Hz, and the recording time was 44 s for I = 1 A and 12 s for I = A. After recording, the waveforms were averaged to reduce noise just as in the case we measure a human evoked response. We applied different averaging numbers, namely,, 4, 8, 12, and 16 for I = 1 A, and and 4 for I = A, so as to consider different signal-to-noise ratios. Moving-average processing was also conducted with a window length of 16.5 ms to reduce power-line interference (6 Hz). Then, source localization using the Sarvas formula was conducted for each data set. - correspond to different averaging numbers and applied amplitude, 4, 8, and 16 for I = 1 A, and and 4 for I = A, respectively. The waveform detected at 54 measuring points is overlapped. The applied waveform when I = 1 A is shown in Fig. 4 (h). Figure 5 shows the contour maps of the measured magnetic field distributions. Figure 5 - are the same as those of Fig. 4. The time point of the displayed data was the first peak of the sinusoidal waveform, indicated by a triangular arrow in Fig. 4(h). The source estimation was conducted using a least-mean-square method and the Sarvas formula. Figure 6 shows the source localization error and goodness-of-fit (GOF) value in the estimation. Figure 6- are the same as those of Figs. 4 and 5. Source estimation was performed at every four peaks of the sinusoidal waveform; the length of the bar indicates the mean value of the source localization error and the GOF. By increasing the signal-to-noise ratio, the source localization error decreased and the GOF increased. 3. Result 4. Discussion Figure 4 shows the waveforms of measured data and applied in (h). The measured waveforms in The amplitude of the magnetic signal from the human brain detected by a SQUID-based MEG system 72

Source localization error [mm] Goodness of fit [%] 8 6 4 2 8 6 4 2 1 A A 4 8 12 16 4 Averaging number Fig. 6 Source localization error and goodness of fit in ECD analysis. is typically found to be approximately 1 pt or less. However, larger waveforms, as shown in Fig. 4, can be detected by a room-temperature sensor that was located much closer to the target. These results show the possibility of realizing a room-temperature sensor-based MEG system. When a new magnetic sensor is developed or the sensitivity of a magnetic sensor is improved, the averaging number used to observe the biomagnetic signal is usually considered a criterion for the evaluation of its performance. As shown in Fig. 6, the source localization error with different averaging numbers can be obtained using the phantom. For example, we conclude that 4.2 mm of accuracy and 8% of GOF can be achieved with 16-times averaging for MEG measurements when using the. In the case of MEG measurement using a SQUID-based system, the averaging number is usually set to approximately, in consideration of the trade-off between signal-to-noise ratio and fatigue and/or the duration of concentration of a subject. In contrast, we choose 16-times averaging as a maximum to obtain a better signal-to-noise ratio. One of the benefits of using the phantom is high reproducibility of the measurement result with a high signal-to-noise ratio based on long-duration measurement. Furthermore, we also carried out measurements at a amplitude of A such that the signal amplitude was 1-times-larger than the human MEG signal. The obtained signal-to-noise ratio is equivalent to that with a -times-larger averaging number because the noise decreases in proportion to the square root of the averaging number. Therefore, the results in Fig.6 and correspond to the source localization errors and GOF values at an averaging number of and 4 for I = 1 A, respectively. By applying a large electric to the phantom, we can obtain a result equivalent to using a large averaging number. From these results, another conclusion is obtained: 4. mm of accuracy and over 99% of GOF can be achieved with 4-times averaging if the sensor noise decreases to 1/1. These conclusions provide the target specifications of the room-temperature magnetic sensors used to realize MEG measurements. In addition, we should point out the value of the source localization error. In this experiment, the smallest source localization error was 4. mm when I = A and the averaging number is 4. This error was much larger than that obtained by the SQUID-based MEG systems 7). A lower signal-to-noise ratio, smaller measuring points, and a lack of accuracy of sensor positioning are considered to be the causes of the larger source localization error. Specifically, the accuracy of the sensor positioning is supposed to be the major cause of the source localization error because there is a large magnetic field gradient near the signal source comparing with that of SQUID-based MEG systems 1). It is also important to accurately calibrate the sensor position and orientation to realize the MEG system. 5. Conclusion We demonstrated the experimental evaluation of the using the calibrated MEG phantom. The signal source was estimated from the observed magnetic field distribution at different signal-to-noise ratios. The results showed the possibility (and difficulty) of realizing MEG measurements using the MI sensor. The use of the calibrated phantom is effective for evaluating the performance of magnetic sensors. Acknowledgements This research was partly supported by The Hokuriku Industrial Advancement Center. References 1) S. Yabukami, K. Kato, T. Ozawa, N. Kobayashi, and K. I. Arai: J. Magn. Soc. Jpn., 38, 25 (214). 2) H. Karo, and I. Sasada: J. Appl. Phys, 117, 17B322 (215). 3) T. Yamamoto, K. Tashiro, and H. Wakiwaka: The Papers of Tech. Meeting on Magnetics, MAG-15-9, 41 (215). 4) H. Xia, A. B-A. Baranga, D. Hoffman, and M. V. Romalis: Appl. Phys. Lett., 89, 21114 (26). 5) K. Wang, S. Tajima, Y. Asano, Y. Okuda, N. Hamada, C. Cai, and T. Uchiyama: Proc. of the 8th Intl. Conf. on Sens. Tech., 547 (214). 6) Y. Ando: Journal of Japan Biomagnetism and Bioelectromagnetics Society, 29, 2 (216) 7) D. Oyama, Y. Adachi, M. Yumoto, I. Hashimoto, and G. Uehara: J. Neurosci. Methods, 251, 24 (215). 8) J. Sarvas: Physics in Medicine and Biology, 32, 11 (1987) 9) R. J. Illmonieimi, M. S. Hamalainenm, and J. Knuutila: in 73

Proc. Biomagnetism: Applications & Theory, New York, Pergamon, 278 (1985) 1) D. Oyama, Y. Adachi, and G. Uehara: The Papers of Technical Meeting on Magnetics, IEE Japan, MAG-16-1 (216) Received Dec. 22, 216; Revised Mar. 13, 216; Accepted Apr. 5, 217 74