NSG Hard keys for important functions. 5.7 color display, easy to use firmware. 3 power meter

Similar documents
TesT system for ConduCTed and radiated immunity

TEST SYSTEM FOR CONDUCTED AND RADIATED IMMUNITY

TEST SYSTEM FOR CONDUCTED AND RADIATED IMMUNITY

TEST SYSTEM FOR CONDUCTED AND RADIATED IMMUNITY

Radiated Immunity Test System 6 GHz

Radiated immunity test system 6 GHz

RADIATED IMMUNITY TEST SYSTEM 6 GHz

CAL U100B CAL U100B CDN M016 CAL U100B CDN M016 CAL U100B. Used as M2 CDN. Used as M3 CDN

MONITORING DEVICE 4 khz to 400 MHz

Coupling / decoupling network (CDN) for screened or coaxial cables

COUPLING / DECOUPLING NETWORK (CDN) CDN AF TYPE, CDN CAN

CWS 500N1.3 CONTINUOUS WAVE SIMULATOR, 80W

CWS 500N1.4 CONTINUOUS WAVE SIMULATOR, 80W

CWS 500N1.4 CONTINUOUS WAVE SIMULATOR, 80W

COUPLING NETWORK (CN) FOR IEC / EN , DC TO 150 khz

THE MODULAR SOLUTION FOR 6 KV APPLICATIONS

CDN 117 / 117-M CDN 118-T4 / 118-EXT-1 SIGNAL & DATA LINE COUPLING NETWORKS USER MANUAL M

Keysight Technologies N9320B RF Spectrum Analyzer

Agilent N9320B RF Spectrum Analyzer

CONDUCTED RF EQUIPMENT POWER AMPLIFIERS. Practical RF Immunity System Design Considerations

Model 865 RF / Ultra Low Noise Microwave Signal Generator

Portable Multi-Channel Recorder Model DAS240-BAT

DSA700 Series Spectrum Analyzer

Electronic AC Load ZSAC Series. 400 W up to 21,000 W 260 V up to 440 V 3 A up to 100 A. Rev. 3.03

Spectrum Analyzers 2680 Series Features & benefits

GTEM cells. Emissions and immunity testing in a single, shielded environment

R&S SMB100N SIGNAL GENERATOR

Immunity Test System RIS 3000 / RIS 6000 acc. to IEC/EN

CAR - TEST - SYSTEM 14

DG5000 series Waveform Generators

RADIATED IMMUNITY TEST SYSTEMS

GFT1504 4/8/10 channel Delay Generator

JD723A/JD724B/JD726A Cable and Antenna Analyzers

COUPLING DECOUPLING NETWORKS FOR IEC / EN

Vector Network Analyzers ZVB

We re In The Business Of Making Your Life Easier

ArbStudio Arbitrary Waveform Generators. Powerful, Versatile Waveform Creation

Spectrum Analyzer R&S FS300

Advanced Test Equipment Rentals ATEC (2832)

Schlöder GmbH - EMC Test and Measurement Systems Model #

SIGNAL GENERATORS. MG3633A 10 khz to 2700 MHz SYNTHESIZED SIGNAL GENERATOR GPIB

2400C Series Microwave Signal Generators 10 MHz to 40 GHz. Preliminary Technical Datasheet. Low Phase Noise and Fast-Switching Speed in a Single Unit

ArbStudio Arbitrary Waveform Generators

GFT Channel Digital Delay Generator

RF Signal Generator RIGOL TECHNOLOGIES, INC.

Kistler LabAmp for DynoWare

Function/Arbitrary Waveform Generator

Complimentary Reference Material

CALIBRATION KIT FOR EFT / BURST CAPACITIVE COUPLING CLAMP INA 3425 USER MANUAL A

DRTS 66 The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

FREQUENCY SYNTHESIZERS, SIGNAL GENERATORS

400 W up to 21,000 W 260 V up to 440 V 3 A up to 100 A. Electronic Load ZSAC

Model 845-M Low Noise Synthesizer

Specification for Radiated susceptibility Test

Network Analyzers. R3765G/3767G Series. R3765G/67G Series Network Analyzers. 300 khz to 3.8 GHz/300 khz to 8 GHz

Features 100A400AM20. 4kHz 400MHz Class A Portable Full VSWR tolerant CE & RoHS compliant High Efficiency

WaveStation Function/Arbitrary Waveform Generators

DG4000. Series Function/Arbitrary Waveform Generator RIGOL TECHNOLOGIES, INC.

Dual Channel Function/Arbitrary Waveform Generators 4050B Series

Chapter 5 Specifications

Function/Arbitrary Waveform Generator

Programmable AC Power Source Model 9801

Arbitrary/Function Generators AFG3000C Series Datasheet

Berkeley Nucleonics Test, Measurement and Nuclear Instrumentation since 1963

DSA800. No.2 RIGOL TECHNOLOGIES, INC. All-Digital IF Technology 9 khz GHz Frequency Range

Operation. Displayed channel. Measuring range. Status indication/ remote control Key lock Measuring mode/ time constant. Scale.

Handheld Spectrum Analyzer R&S FSH3

EMC TEST SYTEMS / INSTRUMENTS AND CONTROL SOFTWARE

SIGNAL RECOVERY. Model 7265 DSP Lock-in Amplifier

Model 745 Series. Berkeley Nucleonics Test, Measurement and Nuclear Instrumentation since Model 845-HP Datasheet BNC

100U1000. Features. 100 watts CW 100kHz 1000MHz Class A Portable Full VSWR tolerant CE & RoHS Compliant High Efficiency

Models 296 and 295 combine sophisticated

Arbitrary/Function Generator AFG1000 Series Datasheet

WaveStation Function/Arbitrary Waveform Generators

Handheld Spectrum Analyzer R&S FSH khz to 3 GHz

Fluke 1740 Series. Three-Phase Power Quality Loggers Memobox. Assess power quality and conduct long-term studies with ease

EMC/EMI MEASURING INSTRUMENTS & ACCESSORIES SHORT-FORM CATALOG 2009

EMC/EMI MEASURING INSTRUMENTS & ACCESSORIES SHORT-FORM CATALOG 2011

DG4000 Series Waveform Generators

evolution wireless G4 ew 500-G4-MKE 2 Lavalier Set

RF Conducted Immunity and Automotive Transient Generator Test Systems

Spectrum Analyzer RIGOL TECHNOLOGIES,INC.

Spectrum Analyzer. Distribution in the UK & Ireland

EN 55015: 2013 Clause Pass. EN 55015: 2013 Clause Pass. EN 55015: 2013 Clause Pass

Fast transient burst simulator

DSA800. No.1 RIGOL TECHNOLOGIES, INC.

R&S ZNB Vector Network Analyzer Specifications

Microwave. Accessories for Microwave Scalar and System Analyzers

DIFFERENTIAL CURRENT GENERATOR «POCDIF» (AC/DC - 32A - 50V - 12 ranges)

GPS10RBN-26: 10 MHz, GPS Disciplined, Ultra Low Noise Rubidium Frequency Standard

Handheld Spectrum Analyzer R&S FSH 3

CMC 256plus - protection relay test set and universal calibrator

Agilent N9320B RF Spectrum Analyzer

No.2 RIGOL TECHNOLOGIES, INC.

Fluke 1740 Series. Three-Phase Power Quality Loggers Memobox. Assess power quality and conduct long-term studies with ease

Model 310H Fast 800V Pulse Generator

R&S OSP Open Switch and Control Platform Specifications

R&S ZNC Vector Network Analyzer Specifications

Laboratory Grade Instruments Series & 4021 Power Meter SERIES Power Sensor

IEC Electrical fast transient / Burst immunity test

Transcription:

The, successor of the NSG 070, is a multifunctional EMC immunity test system. Its large frequency range from to G and its modular set-up using internal or external amplifiers enable a large variety of applications including tests according to IEC 000--, various BCI applications as well as signal generator and power meter for test systems as per IEC 000--, IEC 000--0, IEC 000-- and many other applications. The powerful and easy to use firmware makes the independent from an external PC and control software, however it can also be remote controlled for system operation. A state-of-the-art data transfer of test and measurement data for documentation is provided by stick to be plugged into the front panel. Integrated signal generator to G power meter inputs to G Integrated class A power amplifier module for different applications Multiple EUT monitoring options,7 TFT color display Internal, menu-based control software Basic remote control software and report generator included External access to signal generator output and power amplifier input and output power meter inputs.7 color display, easy to use firmware Hard keys for important functions User port for TTL inputs and TTL outputs and supply voltages for individual monitoring and control applications Analog, digital and optical monitoring inputs for extensive EUT monitoring options Remote control via optical RS, RS, LAN or x, 0 reference output, Trigger input, external modulation input www.teseq.com 8-0 E0 Feb. 0

Technical specifications Generator Frequency range: G Resolution: Reference frequency: 0 Aging: ppm Level Level range: -0 to +0 Resolution: 0. db Settling time: 0 ms Amplitude modulation Modulation depth: 0 00% Modulation frequency range: 0 Frequency resolution: Pulse modulation Rise / fall time (0% / 0%): < µs Modulation frequency range: 0 Frequency resolution: Duty cycle: 0% to 0% External modulation Delay time: < µs / 80 Period: min. 0 µs Pulse width: min. 0 µs Frequency range: Linear measurement range channel : channel,: Max. input/no damage channel -: Noise level: Input return loss: Connector: Accuracy 0 to 0 C: G - to +7 - to +0 +8 > db below the measurement range >0 db (below 00 ), >7 db (00 to G) BNC socket, 0 Ω <0. db, typ. <0. db www.teseq.com 8-0 E0 Feb. 0

amplifier Nominal output power: 0 W 0 W 7 W Frequency range: 0 0 0 0 0 0 Input impedance: 0 Ω 0 Ω 0 Ω Output impedance: 0 Ω 0 Ω 0 Ω Input return loss: min. 0 db min. 0 db min. 0 db Output return loss: nominal min.. db, 0 db without damage nominal min.. db, 0 db without damage nominal min.. db, 0 db without damage Gain: min. db min. db min. 0 db Gain flatness: max. +/- db max. +/- db max. +/- db Saturated output power: min. min. min. 8.7 Max. input power linear without damage: < -. max. +0 < -. max. +0 < - max. +0 nd harmonic distortion at nominal output power: typ. < -0 dbc typ. < -0 dbc typ. < - dbc rd harmonic distortion at nominal output power: typ. < -0 dbc typ. < -0 dbc typ. < -8 dbc www.teseq.com 8-0 E0 Feb. 0

Test and measurement routines Firmware: Generator mode Sweep: Modulation: Others: frequency sweep, level sweep AM, AM PC (peak conservation), pulse modulation and external free parameter setting from to G, high power mode using power amplifier Firmware: Main generator menu Firmware: Immunity mode Firmware: Immunity test setup Firmware: Calibration result Level: Test methods IEC 000--: Test methods BCI: Sweep: Modulation: EUT monitoring: Calibration: EUT threshold search: Store and recall: Component check: Amplifier saturation check: Additional features: constant or slope test levels, max test levels depending on power amplifier, test routine for IEC 000-- with free selectable test levels in the range to 0 EMF, for BCI tests levels in ma or dbµa CDN, EM clamp, current clamp and direct injection, clamp injection with test level control using monitoring probe substitution method with optional use of the monitoring probe, closed loop method with power limitation (factor adjustable) frequency sweep, sweep function linear, steps per decade, percental and as requested in ISO AM, AM PC (peak conservation), pulse modulation, external or mixed (e.g. AM internal modulated with PM external) individual configuration of the port s functionality, display of events during the test, in the result file and in the test report test set-up and monitoring probe calibration, display, store and recall function of calibration files (limitation of file numbers only by the disk space, typical >0 files) manual search by changing frequency or stress level store and recall function of test configurations, calibration results and test results (number of files is only limited by the disk space, typical >0 files), supports sticks quick check of system components, e.g. cable, attenuator max. db/ db/ 8 db attenuation for 0 W/ 0 W/ 7 W amplifier, max. + db gain at 7 output level validation that the power amplifier is not in saturation for the selected test level including 80% AM, see IEC 000-- Ed. for more information (only available for firmware operation) free parameter setting from to G, supports external power amplifier, switch SW 070, monitoring probe MD 070, directional coupler and attenuator www.teseq.com 8-0 E0 Feb. 0

Windows software General: Remote control: Data transfer: The windows software includes the firmware functionality. The following additional features are available see below. The software allows the use of the report generator and all post processing features without the remote connection to the. remote control of via LAN, or RS transfer between and PC via remote connection or with stick Software: Generator menu Windows software: Generator mode Display: Single step mode: power meter display (units,, ) with reference value setting, min./max. display and export to a log file (frequency, time, power), EUT monitoring display synchronized frequency sweep with power measurement, output as graph and ASCII file (application: scalar analysis on quadripole networks) Software: Immunity test setup Windows software: Immunity mode Sweep: EUT threshold search: EUT monitoring: Additional features: One click report generation: Export function: level sweep with start and stop value or with free editable table, level profile editor and sweep function for BCI tests different opportunities for manual and automatic control power meter use as EUT monitoring device, keyboard activity for test interrupt with possibility for writing test report comments (EUT reaction etc.), output control for user port for each frequency step or each monitoring event output control for user port (to control a switch for the use of two amplifier) tool for test report generation in rtf format, works with different user changeable templates, post processing of measurement data (input for test conditions, EUT parameters and comments), free changeable structure and items of the report, user support of repetitive inputs result and calibration files can be converted to txt files, graphs can be zoomed and converted to jpg files Software: EUT monitoring setup www.teseq.com 8-0 E0 Feb. 0

Analog ports Front panel Generator output: amplifier input: amplifier output: channel to : N socket 0 Ω, G N socket 0 Ω, max. +0 N socket 0 Ω as defined in chapter panel Monitoring input analog: BNC socket, 0- Ri= kω, m resolution External modulation input: BNC socket, impedance >0 kω, level: pp to get 00% AM, 0 0 reference output: BNC socket, approx. pp / 0 Ω Digital ports front panel with ports Front panel : host connector for stick, keyboard, mouse panel User port: Monitoring digital input: Monitoring optical input: Trigger input: RS: RS optical: x : device connector: Network: D-Sub pole TTL inputs TTL outputs + / 800 ma, - / 00 ma, + / 800 ma power supply BNC socket 0- via optical coupler Ri=. kω, switching threshold approx. - LWL (Light wave connector), HP versatile link HFBR00 series 0 kbd, (avoid scattered light on the back panel) BNC socket, TTL for external triggering, max. frequency 00, trigger delay <0 ms D-Sub pole, up to 00 Bd Connector x HFBRx socket for mm fiber optic cable with length between m and 0 m with 00 Bd, for other distances 800 Bd, max. 0 m host connector for stick, keyboard, mouse for remote control RJ, Ethernet 0/00 BASE-T www.teseq.com 8-0 E0 Feb. 0

supply supply unit 00 to 0 AC 0 / 0 autoranging recommended fuse F for nominal 0 recommended fuse F for nominal 0 consumption without power amplifier: approx. 80 W A (slow) 0. A (slow) 0 W module: approx. W A (slow). A (slow) 0 W module approx. 0 W A (slow). A (slow) 7 W module approx. W. A (slow). A (slow) General data Operating temperature range: 0 C to 0 C Storage temperature range: -0 C to 0 C Relative humidity: % / 0 C (no moisture condensation) EMC: DIN/EN -:00 Shock: DIN/EN 008--7 ibration: DIN/EN 008-- Protection class: DIN/EN 00-/IEC 00- Mechanical specifications Size (W x H x D) : Weight: cm ( ) x cm (HU) x. cm (with handle bar and foot) approx. kg (with internal power amplifier), approx. 8 kg (without internal power amplifier) Size of cardboard box: 80 cm x cm x cm (also for options ATN 0xx and/or LE 070 additional space available) Weight of cardboard box: approx. 8 kg (empty) www.teseq.com 8-0 E0 Feb. 0 7

out out out EM-Koppelzange KEMZ 80 0... 0 (000 ) EUT LL LL nd nd LL nd Application for IEC/EN 000--, calibration set-up with CDN db attenuator Compact generator with built-in power amplifier CDN 0 Ω AE-side EUT-side 00 Ω 0 Ω termination 0/0 Ω adapter ch. Ground plane Application for IEC/EN 000--, EUT set-up with CDN Compact generator with built-in power amplifier with CDNs db attenuator Auxiliary equipment AE CDN Equipment under test EUT AE-side EUT-side Insulating Ground plane Insulating Application for IEC/EN 000--, calibration set-up with EM clamp Compact generator with built-in power amplifier db attenuator Termination AE-side EUT-side 0 Ω 00 Ω EM clamp 00 Ω Ground plane 0/0 Ω adapter 0/0 Ω adapter www.teseq.com 8 8-0 E0 Feb. 0

out out EM-Koppelzange KEMZ 80 0... 0 (000 ) EUT LL LL nd nd Application for IEC/EN 000--, calibration set-up with current injection probe Compact generator with built-in power amplifier ch. LE 070, cable set for, consist of: cable, N(m)-N(m), m with one right-angle plug, RG; cable, N(m)-BNC(m), m, RG; cable, BNC(m)-N(m), 0 mm; cable, N(m)-N(m), 0 mm; adapter N(m)-N(m); adapter N(f)-BNC(m) db attenuator 0 Ω termination Calibration jig Current injection probe 0/0 Ω adapter Application for IEC/EN 000--, EUT set-up with EM clamp or current injection probe and for example with use of a monitoring probe Compact generator with built-in power amplifier Ground plane Auxiliary equipment db attenuator ch. Equipment under test AE AE-side EUT-side EUT EM clamp Insulating Ground plane Monitoring probe Insulating recommendation, achievable test levels with db attenuator, 0. db cable loss, max. insertion loss of the coupling device and AM with 80% modulation depth Amplifier module: 0 W 0 W 7 W CDN: EMF 8 EMF 0 EMF EM clamp (KEMZ 80): 0 EMF EMF 0 EMF Current injection clamp (CIP ): EMF EMF 0 EMF (typ.) www.teseq.com 8-0 E0 Feb. 0

out out DIRECTIONAL COUPLER DCP 000 0... 000 DIRECTIONAL COUPLER DCP 000 0... 000 LL LL nd nd Application for automotive BCI, calibration set-up (power requirements and frequency range demand external power amplifier and directional coupler) output ch. stress level ch. forward power ch. reverse power amplifier input 0 Ω Termination Output Directional coupler Calibration jig BCI probe Ground plane Application for automotive BCI, EUT set-up with monitoring probe output ch. level monitoring ch. forward power ch. reverse power automotive BCI solution amplifier input Output Auxiliary equipment AE EUT Directional coupler Insulating BCI probe Monitoring probe Ground plane Equipment under test www.teseq.com 0 8-0 E0 Feb. 0

out out DIRECTIONAL COUPLER DCP 000 0... 000 LL nd LL nd Application for automotive BCI with two power amplifiers, calibration set-up output User port ch. stress level ch. forward power ch. reverse power Switch (part of SW 070) A B Interlock amplifier inputs A B 0 Ω Termination Switch (part of SW 070) DIRECTIONAL COUPLER Calibration jig BCI probe Ground plane Application for IEC/EN 000--0 up to G (power requirements and frequency range demand external power amplifier and directional coupler, field probe control required optional software) Software output 0 Ω ch. n.c. ch. forward power ch. n.c. amplifier input Output GTEM cell Directional coupler www.teseq.com 8-0 E0 Feb. 0

Delivery items for the series Compact immunity test system, - G generator and power meter (power amplifier as selected); remote control software on stick; spare fuses (); RS cable (Nullmodem); USO 0 ( to serial/optical converter with 0 m optical cable); LAN cable, crossover, m; keyboard (English); mains cable GB, CH, USA/JP, EU; operating manual with rack mounting kit Delivery information MD 070 monitoring probe SW 070, switch network xspdt ATN 07, db attenuator, 7 Watts Part number Description -0 Compact immunity test system, - G generator and power meter (without power amplifier) -0 Compact immunity test system, - G generator and power meter (with 0 W module 0-0 ) -0 Compact immunity test system, - G generator and power meter (with 0 W module 0-0 ) 0-7 Compact immunity test system, - G generator and power meter (with 7 W module 0-0 ) 7-0 -TC Traceable calibration (ISO70), order only with the device 8-0 -DKD DKD calibration (ISO70), order only with the device 0 Rack Rack mounting kit for 80 SW 070 Option for : -Switch network x SPDT 00 MD 070 Monitoring device (current sensing probe) active/passive with PSU 00 and LE in storage case 77 USO 0-RS-0 to serial/optical converter, 0 m POF, RS converter 7 WIN 000 Test house software with months support 0 LE 070 cable set for 08 ATN 0 Attenuator W cw N(f)-N(f) 0 ATN 00 Attenuator 0 W cw N(f)-N(f) 07 ATN 07 Attenuator 7 W cw N(f)-N(f), incl. cable LE For CDNs, EM clamp, current injection probes, BCI accessories and antennas please use the web page www.teseq.com. Teseq GmbH Landsberger Str. Berlin Germany T + 0 88 F + 0 88 desales@teseq.com www.teseq.com 8-0 E0 Feb. 0 Teseq is an ISO-registered company. Its products are designed and manufactured under the strict quality and environmental requirements of ISO 00. This document has been carefully checked. However, Teseq does not assume any liability for errors or inaccuracies. Specifications subject to change without notice.