Level Measurement. Continuous level measurement - Radar transmitters SITRANS LR400 5/229. Overview

Similar documents
Level Measurement. Continuous level measurement - Radar transmitters SITRANS LR400 5/229. Overview

Level Measurement. Continuous level measurement Radar transmitters SITRANS LR460. 4/258 Siemens FI

Level Measurement Continuous level measurement Radar transmitters

Level Measurement Continuous level measurement Radar transmitters

Level instruments. Continuous level measurement - Radar transmitters SITRANS LR300. 5/180 Siemens FI Overview

SITRANS L Level instruments

Level Measurement. Continuous level measurement - Radar transmitters SITRANS LR200. 5/200 Siemens FI Overview.

Level instruments. Continuous level measurement - Radar transmitters SITRANS LR200. 5/200 Siemens FI Configuration.

INDUSTRIAL CONTROL INSTRUMENTS FOR PROCESS AUTOMATION. Configuration. Installation

Level Measurement Continuous level measurement - Radar transmitters

Level Measurement Continuous level measurement Radar transmitters SITRANS LR200. Overview. Configuration

Continuous level measurement Radar transmitters

Continuous level measurement Radar transmitters

Level instruments. Continuous level measurement - Radar transmitters SITRANS LR250. 5/210 Siemens FI Overview.

Level Measurement Continuous level measurement - Radar transmitters

SITRANS LR 300: High Performance Radar for Level Measurement

Level Measurement Continuous level measurement - Radar transmitters

Level Measurement. Continuous level measurement - Capacitance transmitters SITRANS LC300 5/271. Overview. Configuration

SITRANS F flowmeters SITRANS F US. Transmitter FUS060. Overview

SITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview

SITRANS T measuring instruments for temperature

Level Measurement. Continuous level measurement Capacitance transmitters SITRANS LC300. icenta Controls Ltd

SITRANS L Level instruments

Temperature Measurement

Level Measurement. 4/2 Overview

OEM radar transmitter, for aggressive media level measurement

Level Measurement. 4/2 Product overview

Level Measurement. 4/2 Overview

Siemens AG Level Measurement

RADAR TRANSMITTERS BLISSFLEX 1100 SELECTION GUIDE. The characters of the order code have been described below

Flow Measurement SITRANS F M. Flow sensor MAG /49. Overview

SITRANS F flowmeters SITRANS F M. Flow sensor MAG /48 Siemens FI Overview

Level measurement Radar

Flow Measurement SITRANS F M

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

2-Wire. Level Gauge BM 702

SITRANS L Level instruments

Instruction Manual September sitrans LR 300

Flow Measurement SITRANS F M. Transmitter TRANSMAG 2 with sensor 911/E 4/101. Overview

SITRANS T measuring instruments for temperature

LEVEL WITH US. to Effectively Minimize Process Upsets. 25 GHz pulse radar for liquids and slurries in general service and process applications

SITRANS LR 400. Instruction Manual November 2001

Temperature Measurement

Flow Measurement SITRANS F M

Instruction Manual September sitrans LR 300 (HART)

TEK-F LEX 4100A. Guided Wave Radar Level Transmitter. LEVEL. Technology Solutions

Instruction Manual May iq radar

3DLevelScanner. Technical Data Sheet. Level Sensor. Non-Contact, Multiple-Point Measurement

SITRANS F flowmeters SITRANS F US SONOCAL /184 Siemens FI

Servo Gauge 854 XTG. Global Experience. Locally Applied. Cut costs, not repeatability.

OPTIFLUX 5000 Technical Datasheet

Instruction Manual May sitrans LR300

PiloTREK SZINTTÁVADÓK. Pulse burst radar level transmitters 5 YEARS WARRANTY

PiloTREK SZINTTÁVADÓK LEVEL TRANSMITTERS PU L S E BU RS T R A DA R LE V E L TR A NSMIT TERS K- BA N D R A DA R FO R LI Q U I DS

FLOWMETER. Siemens MAG 5000/6000. Overview

OPTIFLUX 5000 Technical Datasheet

Temperature Measurement Transmitters for mounting in sensor head

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 1.5 s adjustable. 20 ms. 60 ms. 60 ms. Approx. 1.

SITRANS F C. Flowmeter SITRANS FC430 3/151. Technical specifications. Overview

TLR wire System Level Radar. MICROWAVE level meter GENERAL FEATURES OPERATION PRINCIPLE

Rosemount TGU 65 Tank Radar Gauge, Still Pipe Antenna

Instruction Manual August sitrans LR 200

SITRANS F flowmeters SITRANS F US. Transmitter FUS080. 4/194 Siemens FI

Radar Level Measurement micropilot FMR 130 for stilling wells

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 20 ms. 60 ms. 60 ms. Approx. 1.3 kg. Approx. 0.9 kg. Approx. 5.

3DLevelScanner. Technical Data Sheet. Level Sensor. Non-Contact, Multiple-Point Measurement

Coriolis Massflowmeter

Positioner with HART Communication Type 3780

Kotron Model 82 CE RF Level Transmitter

The Radar Level Meters can be installed both in metallic or non metallic tanks; their use is not harmful to humans or environment.

Process display RIA 261

SITRANS P. Transmitters for level. Introduction 1/42. Application

ENRAF SERVO GAUGE 854 ATG Setting the standard in gauging.

Main features. Operation. LEVEL Transmitters

K-BAND RADAR FOR LIQUIDS

TEK-TEMP 2100A. Explosion-Proof Temperature Transmitter. TEMPERATURE. Technology Solutions

APT3200L SMART PRESSURE TRANSMITTER. Application Areas: WITH DIAPHRAGM SEAL

Ultrasonic level transmitter, non-contact

Coriolis Massflowmeter

IQ RADAR 300. Instruction Manual March 2001

LST100 Ultrasonic level transmitter for upstream oil and gas

Rosemount 3101, 3102, and 3105

MJK Expert 700 / 800 / 900 / 1100 / 2100 MJK Expert 1400 / 3400

MODEL: B6U-B B6-UNIT. [2] LCD DISPLAY 0: Without 1: With

SITRANS F flowmeters SITRANS F US. SONOFLO SONO 3000 transmitter. 4/152 Siemens FI Overview

Mobrey Ultrasonic. MSP422, MSP400RH, and MSP900GH Level Transmitters. Product Data Sheet February 2015 IP2045, Rev EA

Technical Description. High Performance Radar Microwave Level Gauge

Resistance thermometers for process technology

APT3100 MODEL. Smart Pressure Transmitter. for Differential / Gauge / Absolute Pressure Measurement. Doc. No. : C3100-E05A

Temperature Measurement Transmitters for mounting in sensor head

ED701 General Industry Pressure Transmitter

OPTIWAVE 1010 Technical Datasheet

Special Documentation Levelflex FMP51, FMP52, FMP55, FMP57

Sarasota CM200 Sarasota HME900 Density Converter Electronics

Condumax W CLS15 and CLS15D

Rosemount 5400 Series Radar Level Transmitter

Intrinsically safe pressure transmitter MBS 4201, MBS 4251, MBS 4701 and MBS 4751

Indumax CLS50/CLS50D. Technical Information

Flow Measurement SITRANS F US Inline

SmartLine Non-Contact Radar Level Meter Technical Datasheet. Specification. The Universal Radar Solution. Highlights. Industries.

Transcription:

Overview Application It provides excellent results on low dielectric media. is available for standard applications and for applications that require explosion proof protection. features robust enclosure, flange and horn components. It is virtually unaffected by atmospheric or temperature conditions within the vessel. Safe on-site local programming is simple using the Intrinsically Safe handheld programmer. SIMATIC PDM can be used for easy remote programming. The characteristics of 24 GHz and high signal-to-noise ratio contribute to exceptional signal reflection, regardless of the dielectric value of the medium. Key applications: long-range liquid or slurry applications, high temperature or high pressure, low dielectric media, such as LPG (liquid, petroleum, gas) The is a 4-wire, 24 GHz FMCW radar level transmitter for continuous monitoring of liquids and slurries in storage and process vessels including high temperature and high pressure, to a range of 0 m (164 ft); ideal for low dielectric media. Benefits Easy installation and commissioning, low maintenance Self-calibration with internal reference Built-in diagnostics Auto False-Echo Suppression and advanced echo processing 24 GHz and high signal-to-noise ratio Communication using HART or PROFIBUS PA Programming using infrared Intrinsically Safe handheld programmer or with SIMATIC PDM or HART handheld device Configuration Beam angle Installation in Mounting Nozzle Mounting unit on vessel 13 9 Short horn antenna Long horn antenna 10 (0.39) Conical Flat Parabolic Note: For best signal, always use largest horn size possible. installation, dimensions in mm (inch) Siemens FI 01 2011 /229

Technical specifications Mode of operation Measuring principle Frequency Measuring range Output Analog output (HART ) Signal range Load FMCW radar level measurement 24... 2 GHz FMCW 0.3... 0 m (1.1... 164 ft) Optically isolated 4... 20 ma Max. 600 Ω (330 Ω for [ia] versions, Area classification options G, L, P, S) Relay NC or NO function, max. DC 0 V, max. 200 ma, rating W Communication HART, optional PROFIBUS PA PROFIBUS PA protocol Layer 1 and 2, Class A, Profile 3.0 Performance (Reference conditions) Dead band Error in measurement at +2 C (+77 F) Repeatability Fail-safe Rated operating conditions Amb. temperature for enclosure Location Installation category Pollution degree 4 Medium conditions 0... 30 mm from bottom edge of flange mm from 2... 10 m 1 mm from 10... 0 m 1 mm Dielectric constant ε r > 1.4 Process temperature range Standard With optional temperature extension Vessel Pressure Design ma signal programmable as high, low or hold (LOE) -40... +6 C (-40... +149 F) Indoor/outdoor II -40... +200 C (-40... +392 F) -20... +200 C (-4... +392 F) for with ATEX rating -40... +20 C (-40... +482 F) Up to 40 bar g (process connection dependent) Weight Approx. 12.2 kg (26.8 lbs) with 3" 10 psi flange Materials Enclosure Degree of protection Cable inlet Process connections Die-cast aluminum, painted IP67/Type 4X/NEMA 4X, Type 6/NEMA 6 2x M20x1. or ½" NPT Flat faced flanges 316L stainless steel, 80, 100, 10 mm, bolt holes matching EN 1092-1 and JIS B 2220 Raised face flanges 316L stainless steel, 3", 4", 6", bolt holes matching ASME B 16. Programming Intrinsically Safe Siemens handheld programmer (ordered separately) Approvals for handheld programmer Infrared receiver IS model with ATEX EEx ia IIC T4, CSA/FM Class I, Div. 1, Groups A, B, C, D T6 at max. ambient temperature of +40 C (+104 F) Handheld communicator HART communicator 37 PC Display (local) SIMATIC PDM Alphanumeric LCD for readout and entry Power supply 100... 230 V AC ± 1 % (0/60 Hz), 6 W (12 VA) or 24 V DC +2/-20 %, 6 W (optional) Certificates and approvals Safety Shipping Radio Hazardous areas Optional equipment CSA US/C, CE, FM, C-TICK Lloyd s Register of Shipping ABS Europe (R&TTE, CETECOM), Industry Canada, FCC, C-TICK ATEX II 1/2 G EEx dem [ia] IIC T6 ATEX II 1/2 G EEx dem IIC T6 CSA/FM Class I, Div. 1, Groups B, C, D; Class II, Div. 1, Groups E, F, G; Class III T6, INMETRO Purging (self-cleaning) system PTFE dust cover /230 Siemens FI 01 2011

Selection and Ordering data 4-wire, 24 GHz FMCW radar level transmitter for continuous monitoring of liquids and slurries in storage and process vessels including high temperature and high pressure, to a range of 0 m (164 ft); ideal for low dielectric media. Order handheld programmer separately! Process temperature range -40 C... +200 C (-40... +392 F), standard 0-40 C... +20 C (-40... +482 F), 1 high temperature extension Process connection Universal flange 3"/80 mm 1) Universal flange 4"/100 mm 1) Universal flange 6"/10 mm 1) DN 80, PN 16, Type A, flat faced DN 80, PN 40, Type B1, raised face DN 100, PN 16, Type A, flat faced DN 100, PN 40, Type B1, raised face G DN 10, PN 16, Type A, flat faced U 3" ASME, 10 lb, raised face E 3" ASME, 300 lb, raised face F 4" ASME, 10 lb, raised face J 4" ASME, 300 lb, raised face K 6" ASME, 10 lb, raised face N JIS, DN 80 10K Q JIS, DN 100 10K R JIS, DN 10 10K (Note: Flange bolting patterns and facings dimensionally correspond to the applicable ASME B16., or EN 1092-1, or JIS B 2220 standard.) Antenna Horn antenna, long 93 mm (3.66") diam. for 100 mm (4") nozzles Horn antenna, short 74 mm (2.91") diam. for 80 mm (3") nozzles L) 7 M L 4 2 1 - Antenna purging system None 0 Purging system 1 Note: Available with process connections A, B or D, only, and available for Area Classifications A or B only 77777-7777 Process seal/gasket PTFE for -40... +20 C (-40... +482 F) flange 1 temperatures FKM for -20... +200 C (-4... +392 F) flange temperatures 3 2) Output/communication 4... 20 ma, HART 0 PROFIBUS PA 1 Power supply/cable inlet 100... 230 V AC 2 x M20x1. 2 x ½" NPT 24 V DC 2 x M20x1. 2 x ½" NPT Area classification General Purpose, CSAUS/C, Industry Canada, FCC, CE and R&TTE ATEX II 2G EEx d IIC T6; CE, R&TTE ATEX II 2G EEx dem IIC T6; CE, R&TTE ATEX II 2G EEx dem [ia] IIC T6; CE, R&TTE 3) ATEX II 1/2 GD EEx d IIC T6; CE, R&TTE 2) ATEX II 1/2 GD EEx dem IIC T6; CE, R&TTE 2) ATEX II 1/2 GD EEx dem [ia] IIC T6; CE, R&TTE 2) 3) L A B D S C T V D K B C E F B E F G J K Selection and Ordering data 4-wire, 24 GHz FMCW radar level transmitter for continuous monitoring of liquids and slurries in storage and process vessels including high temperature and high pressure, to a range of 0 m (164 ft); ideal for low dielectric media. Order handheld programmer separately! FM Class I, Div. 1, Groups B, C, D; Class II/III, D) T Div. 1, Groups E, F, G; FCC 2) CSA Class I, Div. 1, Groups B, C, D; Class II/III, Div. 1, Groups E, F, G; FCC 2) D) U Local operation Local Display Only. Handheld programmer not included (Order programmer separately.) 1) Available with antenna purging system option 1 only, universal, 0. bar g (7.2 psi g) maximum 2) Available with process temperature range option 0 only 3) Available only with power supply option E or F D)Subject to export regulations AL: N, ECCN: EAR99H L) Subject to export regulations AL: N, ECCN: 3A991X Selection and Ordering data Further designs Please add "-Z" to and specify Order code(s). Stainless steel tag [69 x 0 mm (2.71 x 1.97")]: Measuring-point number/identification (max. 16 characters); specify in plain text Test certificate: Manufacturer's test certificate M to DIN 30, Part 18 and to ISO 9000 Inspection Certificate Type 3.1 per EN 10204 Operating Instructions English German French Spanish Note: The Operating Instructions should be ordered as a separate line item on the order. L) 7 M L 4 2 1-77777 -7777 Order code Y1 C11 C12 C) 7ML1998-FH06 C) 7ML1998-FH36 C) 7ML1998-FH16 C) 7ML1998-FH22 Multi-language Quick Start manual C) 7ML1998-QN83 This device is shipped with the Siemens Milltronics manual CD containing the complete ATEX Quick Start and Operating Instructions library. 2 Siemens FI 01 2011 /231

Accessories Handheld programmer Intrinsically Safe, EEx ia Long horn dust cover, PTFE Short horn dust cover, PTFE HART modem/rs-232 (for use with a PC and SIMATIC PDM) HART modem/usb (for use with a PC and SIMATIC PDM) One metallic cable gland M20x1., rated -40... +80 C (-40... +176 F), HART 1) One metallic cable gland M20x1., rated -40... +80 C (-40... +176 F), PROFIBUS PA 1) SITRANS RD100 Remote display - see Chapter 8 SITRANS RD200 Remote display - see Chapter 8 SITRANS RD00 Remote display - see Chapter 8 7ML830-2AJ 7ML1930-1AH 7ML1930-1AJ D) 7MF4997-1DA D) 7MF4997-1DB 7ML1930-1AP 7ML1930-1AQ 1) Product shipped with plastic cable gland, rated to -20 C. If -40 C rating required, then metallic cable gland is recommended. C) Subject to export regulations AL: N, ECCN: EAR99 D) Subject to export regulations AL: N, ECCN: EAR99H /232 Siemens FI 01 2011

Specials Specials Specials 3"/80 mm Universal Flange, without horn or hub. 1) 4"/100 mm Universal Flange, without horn or hub. 1) 6"/10 mm Universal Flange, without horn or hub. 1) 8"/200 mm Universal Flange, without horn or hub. 1) Purging kit with Easy Aimer ball, no flange, no horn. 1) Purging kit with Easy Aimer ball with 4"/100 mm flange, no horn. 1) Purging kit with Easy Aimer ball with 6"/10 mm flange, no horn. 1) Purging Kit with Easy Aimer ball with 8"/200 mm flange, no horn. 1) Short horn antenna, no emitter supplied 103813 103814 10381 103816 1036110 103810 103811 103812 2247K1A Aluminum cable inlet, HART communication, and GP, CE, and CETE- COM approvals. Aluminum and GP, CE, and CETECOM approvals. Aluminum cable inlet, HART communication and GP, CE, CSA, Industry Canada, FCC and R&TTE. Aluminum and GP, CE, CSA, Industry Canada, FCC and R&TTE. C) 1036479 1036480 C) 103867 C) 103871 Long horn antenna, no emitter supplied Short horn antenna, purged, no emitter supplied Long horn antenna, purged, no emitter supplied Replacement display module, Liquids and Solids versions 4" extension kit for horn antenna with General Purpose approvals 8" extension kit for horn antenna with General Purpose approvals 8" extension kit for horn antenna for hazardous units 2247K2A 2247K3A 2247K4A 103410 103474 103473 1036180 Aluminum and ATEX II 1/2 GD EEx d IIC T6, CE and R&TTE approvals. Aluminum cable inlet, HART communication and and GP, CE and CETE- COM approvals. Aluminum and GP, CE and CETECOM approvals. Aluminum cable inlet, HART communication and GP, CE, CSA, Industry Canada, FCC and R&TTE C) 103873 C) 1036481 1036482 C) 1036483 Aluminum and GP, CE, CSA, Industry Canada, FCC and R&TTE. C) 1036484 Aluminum cable inlet, HART communication and ATEX II 1/2 GD EEx d IIC T6, CE and R&TTE approvals. C) 103648 Aluminum and ATEX II 1/2 GD EEx d IIC T6, CE and R&TTE approvals. C) 1036486 1) Available with no pressure rating and with General Purpose approvals only Please contact nacc.smpi@siemens.com for special requests. C) Subject to export regulations AL: N, ECCN: 3A991X Siemens FI 01 2011 /233

Characteristic curves 30.0 Flange 22482 or 22487, FF Standard Process Seal 4.0 Flange 22482 or 22487, FF Process Seal for Hazardous Locations Pressure (bar, gauge) 2.0 20.0 1.0 10.0.0 Pressure (bar, gauge) 40.0 3.0 30.0 2.0 20.0 1.0 10.0.0 0.0-100 -0 0 0 100 10 200 20 Temperature ( C) 300 0.0-100 -0 0 0 100 10 200 20 300 Temperature ( C) 80 mm, 100 mm, PN40 80 mm, 100 mm, PN40 10 mm, PN40 10 mm, PN40 80 mm, 100 mm, 10 mm, PN16 or 10K 80 mm, 100 mm, 10 mm, PN16 or 10K 30.0 Flange 22483 or 22488, RF Standard Process Seal ATEX II 2 G Approval options 60.0 Flange 22483 or 22488, RF Process Seal for Hazardous Locations ATEX II 1/2 G Approval options 2.0 0.0 Pressure (bar, gauge) 20.0 1.0 10.0 Pressure (bar, gauge) 40.0 30.0 20.0.0 10.0 0.0-100 -0 0 0 100 10 200 20 Temperature ( C) 3", 4", 300# 6", 300# 3", 4", 6", 10# 300 0.0-100 -0 0 0 100 10 200 20 300 Temperature ( C) 3", 4", 300# 6", 300# 3", 4", 6", 10# Process Pressure/Temperature derating curves /234 Siemens FI 01 2011

SITRANS LR400 Dimensional drawings (7ML421) (with temperature extension) Maximum Flange and Process Temperature Versus Allowable Ambient Temperature Connection cover Electronics cover Intermediate flange Threaded ring 204 (8.0) 27 (10.1) Earth terminal 204 (8.0) 384 (1.1) Ambient Temperature ( C) 70 60 0 40 30 20 10 0 0 2 0 7 100 12 10 17 200 22 20 27 Process Temperature ( C) Standard Optional temperature extension Process flange Horn antenna 74 (2.9) 191 (7.) 238 (9.4) 74 (2.9) 191 (7.) 238 (9.4) 93 (3.7) 93 (3.7), dimensions in mm (inch) Siemens FI 01 2011 /23

Schematics AC version Cable clamp Earth terminal DC version Cable clamp Earth terminal Hand Programmer HART HART Part number: 7ML830-2AJ Cable clamp Earth terminal Cable clamp Earth terminal PROFIBUS PA PROFIBUS PA Note: Recommended torque on terminal clamping screws, 0. to 0.6 Nm 4-20 ma, Profibus PA, DC input circuits, 14-20 AWG, shielded copper wire AC input circuit, min. 14 AWG copper wire All field wiring must have insulation suitable for at least 20 V The equipment must be protected by a 1 A fuse or circuit breaker in the building installation connections /236 Siemens FI 01 2011