Occupancy Sensor OCS 100C Setup Guide

Similar documents
Occupancy Sensor OCS 100C Setup Guide

Occupancy Sensor OCS 100W Setup Guide

Occupancy Sensor OCS 100W Setup Guide

Occupancy Sensor OCS 100C Setup Guide

ECM S10 Partition Sensor Setup Guide

Dual Technology Ceiling Mount Sensor

Dual Technology Wall Mount Occupancy Sensor

Dual Technology Wall Mount Occupancy Sensor

CONTENTS OF THE BOX. *PIR sensor only **Dual Technology and PIR sensors only. Description PIR Ultrasonic Dual Technology

with Light Level, Isolated Relay and Manual On features

NetPA AT Series Setup Guide

ETC Installation Guide

INSTALLATION MANUAL ES-SUB-WIRELESS-KIT ES-SUB-WIRELESS-RCVR

Infrared Wall Mount Occupancy Sensor

SUPERPLANE 2.5 INSTALLATION INSTRUCTIONS WALL/SURFACE BACK MOUNT. A nd Avenue, Unit 1 Oakland,

INSTALLATION INSTRUCTION Silo Multiples - New Construction Housing MT-4*15, MT-4*10

2 Pendant Adjustment. Pendant Slider Plate. 3/4 (19mm) IP, (29mm) O.D. Knockouts. 1/2 (13mm) IP, (22mm) O.D. Knockout

BT11 Hardware Installation Guide

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE

ROUND LIGHTPLANE 1 3D FLUSH

Lenovo regulatory notice for wireless adapters

Polycom VoxBox Bluetooth/USB Speakerphone

CXB Series SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. LED Luminaire TO INSTALL: INSTALLATION INSTRUCTIONS INSTRUCTIONS D INSTALLATION

v3 360 Passive Infrared Line Voltage Occupancy Sensor

Installation Instructions

WRZ-SST-120 Wireless Sensing System Tool

INSTALLATION INSTRUCTIONS SUPERPLANE 4 WALL MOUNT. A nd Avenue, Unit 1 Oakland, CA P E W alwusa.

SUPERPLANE TM 4 RECESSED SP4R

Blue Node. User Manual

XtremeRange 5. Model: XR5. Compliance Sheet

Axon Signal Unit Installation Manual

INSTALLATION AND SETUP GUIDE

CX-100. Installation Instructions. PIR Occupancy Sensor SPECIFICATIONS

Taxonomies, Classifications, and Categories Residential dimmers, motion sensors, controls, & photo cells Wireless occupancy/vacancy sensor

NV-WA40W. Installation and User Guide

Mid-Power Expansion Unit (MxU) Quick Installation Sheet

1100DH High Power Wireless Receiver

High Bay Occupancy Sensor for Use with Electronic Ballast HID Luminaires

12V 7Ah 3.15A AC V +12V DC. Paxton Net2 plus 12V DC 12V DC EXIT /100 Ethernet. INPUT AC V 50 / 60 Hz 1.2A OUTPUT DC 13.

FCC Certification Notice: IC Certification

TABLE OF CONTENTS. PixMob Broadcaster 1

12 24 VAC/VDC ±10% (inhibited when voltage is applied) min. pulse width duration = 50 ms. Normal mode or Background Analysis mode

Installation Instructions

Wireless Ceiling Mount Sensor for Occupancy / Vacancy Detection INSTALLATION GUIDE

TE-6300P Series Temperature Sensors

microos Occupant Sensors One Way microostm Occupant Sensor Two Way microostm Occupant Sensor Sensors

DCH-G020 mydlink Connected Home Hub

Installation Instructions

PowerView Remote Control Guide

Occupancy Sensors for High-Bay Applications

TC-LINK -200 Wireless 12 Channel Analog Input Sensor Node

INSTALLATION INSTRUCTION OCULUX 3 LED - New Construction

INSTALLATION INSTRUCTIONS Oculux 3.5 Architectural Remodel

Technical Application Guide

SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE LED SURFACE AMBIENT LUMINAIRE FACTORY SETTINGS. Configuration Value

INSTALLATION INSTRUCTION Accent

INSTALLATION INSTRUCTION Accent

High/Low Bay Passive Infrared Occupancy Sensor

LRF20CR2BPWH Ceiling MNT Wireless Occ Sensor

Installation Instructions RF8010/RF8310 RF8010/RF8310: EXTERNAL ANTENNA

INSTALLATION INSTRUCTION Adjustable Spot - Endurance Sign Lighting

GNSS multiconstellation, GPS+Glonass as a minimum; GSM; Accelerometer; SIM on Chip; Watch Dog; Power Management; RF transceiver; CAN Bus interface

Indoor Contact Input Photosensor

EBDHS-MB-AT-DD. RF ceiling PIR presence detector DALI / DSI dimming. Product Guide. Overview. Features

RFC1000. Wireless Transceiver for the RFOT, Therm A lert and RF2000A data loggers. Product User Guide

802.11a/n/b/g/ac WLAN Module AMB7220

260X190mm/105 克铜版纸 / 黑白印刷

Wireless Occupancy Sensor User Guide

Installation Instructions RF5910

3 GHz Carrier Backhaul Radio. Model: AF-3X. Tel: +44 (0) Fax: +44 (0) LINK GPS MGMT DATA DATA

EA200 uhf EA200 vhf User Guide

ODSOD-ID. D u a l - R e l ay Decora Wall Sw i t c h Occupancy Sensor

MPR kHz Reader

CSD Series Current Devices Solid Core with Relay

DU3 Ultrasonic Vehicle Detector

HIGH/LOW/OFF PIR OUTDOOR PHOTO/MOTION SENSOR IN IP66 ENCLOSURE WITH BLUETOOTH

Warning: Electrical Hazard... 3 Safety Instruction Sheet for STG Product Overview What s in the box?... 4

INSTALLATION INSTRUCTION Grand Accent

Pser G uide oduct Manual

Model: VR-1A INSTALLATION AND OPERATING INSTRUCTIONS

Radio Powr SavrTM Wireless Occupancy / Vacancy Ceiling Sensor

VP1801 Reader Motor Control

IRIS \ IRIS-I QUICK SET-UP GUIDE STEP 1 INSTALL

Clock Radio CR2307 INSTRUCTION MANUAL

EBDSPIR-AT-DD. RF ceiling PIR presence detector DALI / DSI dimming. Product Guide. Overview. Features

1: White buttons Used by the user on a daily basis. 2: Grey buttons Used only upon first startup.

Universal TechBox Series

Tork EasyCube. User Manual.

Murata Bluetooth mesh Node. Installation Guide

INSTALLATION INSTRUCTION Accent

Wireless Ceiling Mount Sensor

LINK GPS MGMT DATA. 4 GHz Licensed Backhaul Radio DATA MGMT GPS. Model: AF-4X LINK

VIBRATION AND TEMPERATURE SENSOR (FY01) USER GUIDE (For FCC/IC Certification) Version: 0.7

ETC Installation Guide

XT-4850C FCC ID: GKM-XT4850C IC: IC: 10281A-XT4850C

APM 6998 WiFi Module Manual

Instruction Sheet. VDM Series. Tilt Low Profile Mount

O ccupancy and Light Level Sensor L ow Vo l tage Ceiling Fixture Mount

FOR TRAINING PURPOSES ONLY DATED MATERIAL. Aperio Hub AH20/AH30 Installation Instructions. ASSA ABLOY, the global leader in door opening solutions

BEA s digital inductive single loop solution

Transcription:

Sensor OCS 00C Setup Guide The OCS 00C is a ceiling mounted occupancy sensor that incorporates ultrasonic (US) and passive infrared (PIR) into a dual technology sensor. The US sensor emits ultrasonic sound waves into an area and measures the speed of their return to detect the presence of people. Frequency changes are caused by the movement of people, which is detected by the US waves. The PIR sensor detects the presence of people based on the difference between the heat generated by moving people versus the ambient room temperature. The OCS 00C has a VDC power input, ground/common connection, normally open/closed relay, photocell, and occupancy output connections. Front Panel Features Ultrasonic Sensors Ultrasonic Sensors Figure. OCS 00C Front Panel Features Green LED (status indicator) Infrared Lens Retainer Ring Green LED (status indicator) Ultrasonic sensors () Detect movement in the room, based on ultrasonic waves. Green LED status indicators () Flashes when the Ultrasonic sensors detect occupancy. Infrared Green Lens LED (status indicator) Infrared lens Diffracts the incoming light and directs Retainer Ring the light to the infrared sensor. Infrared sensor, controls and DIP switches are located below the lens. Red LED status indicator Located below the infrared lens, this LED flashes when the infrared sensor detects occupancy. Retainer Ring Holds the optional IR mask in place. Remove Green LED (status indicator) to access all controls and DIP switches. Control DIP Switches A DIP Switches (A) Red Dial Black Dial A ON B ON DIP Switches (B) Green Dial A OPERATION OFF ON Not used Not used* Not used Threshold Low sensitivity* High sensitivity LED indicator LEDs enabled* LEDs disabled Automatic adjust reset Toggle to reset (Default: OFF) Blue Dial *Default DIP Switches B Figure. OCS 00C Controls Black Timer Dial Ranges from 8 minutes to minutes. Full counter clock wise (CCW) = 8 minutes Full clock wise (CW) = minutes To enter the test mode (8 second timer) follow the steps below:. Open the retainer ring.. Rotate the black timer dial to about midway ( o clock).. Return to minimum setting (full CCW). B OPERATION OFF ON Strong airflow Disabled* Enabled compensator Over doorway mount Disabled* Enabled Timer adjust Automatic Manual* Sensitivity adjust Automatic Manual* *Default. The timer will remain in the 8 second test mode for hour, then automatically reset to 8 minutes. 5. To manually force the timer out of the 8 second test mode, turn the timer adjustment approximately /6" clockwise. The setting will be slightly above minimum (just above the 8 minute setting. Red Infrared Sensitivity Dial Adjust this dial to increase (CW) or decrease (CCW) infrared sensitivity (default = 75%). Green Ultrasonic Range Dial Adjust this dial to increase (CW) or decrease (CCW) ultrasonic sensitivity (default = 50%).

Sensor OCS 00C Setup Guide (Continued) Blue Photocell Dial (see figure on the previous page) Photocell prevents the sensor from turning on when the area is adequately lit with natural light and when motion is detected. The sensor must be mounted directly over an area that is representative of the average, natural room lighting. Before setting the photocell control, wait until the natural light is brightest (optional). Adjust this dial to increase or decrease photocell sensitivity. Turn counter clockwise to decrease photocell sensitivity. Turn clockwise to increase photocell sensitivity. Factory default is 00% (full clockwise). Full clockwise Photocell is disabled. Range 0 to 000 LUX Mask Patterns and Sensor Coverage An infrared mask may be needed to achieve the desired sensory coverage. Any area masked will block the PIR sensor from detecting motion in that area. Full Mask Hallway Hallway Specific Area Masked Center Mount (mask blocks sensor seeing out doorway into hallway) Corner Mount (no mask needed) Conference Room Mask 80º Mask Full Mask Using the Infrared Mask Rectangular Areas Over the Door Typical Mask Patterns Specific Areas to Mask ' ' ' ' 67E Appliance Control Headquarters +.800.6.9876 (Inside USA/Canada Only) USA - West +.7.9.500 +.7.9.57 FAX www.extron.com 68-55-5 Rev. A OCS 00C U.S. Patents: 6559, 59609, 5699, 560, 6505, 60785, D06, 69, 598657, 675995 Not Used Threshold (max Disabled) Center of Sensor Coverage Sensory Coverage US Minor Motion IR Minor Motion US Major Motion IR Major Motion NOTE: These coverage dimensions are achieved when the OCS 00C is installed 0 feet (.0 m) above the coverage area. 5' 6' Figure. Mask Patterns and Sensor Coverage Diagrams

Installation OCS 00C Parts Installation Method Nut Secure Mounting Post to the Tile w/ Nut & washer. Washer Cutting End Mounting Post Twist and lock Threaded Mounting Post into the Cover Plate. Drill into Tile. Threaded Mounting Post Cover Plate Cover Plate Connect building wiring to Wiring Harness with wire nuts. Adjustment Knobs Red: Infrared Range - 75% Default Black: Timer - 8 min to max - min Default Green: Ultrasonic Range -50% Default Blue: Photocell - max Default Match either arrow shown here with the arrow on the twist-lock cover plate. Then inserts the tabs into the slots. Twist until ratchet action indicates engagement. Center of Sensor Coverage Range of adjustment (click turn) 0 Adjustment Insert wiring through Mounting Bracket. A Not Used 67E Appliance Control Headquarters +.800.6.9876 (Inside USA/Canada Only) USA - West +.7.9.500 +.7.9.57 FAX www.extron.com 68-55-5 Rev. A Switch Settings: All switches OFF for full automatice operation A Threshold: OFF = low sensitivity, ON = high sensitivity A LED Control: OFF = LEDs active, ON = LEDs disabled A Automatic Adjust Reset: Toggle to reset B Strong Airflow Compensator: OFF = disable, ON = enable B Over Doorway Mounting: OFF = disable, ON = enable B Timer Adjust: OFF = automatic, ON = manual B Sensitivity Adjust: OFF = automatic, ON = manual U.S. Patents: 6559, 59609, 5699, 560, 6505, 60785, D06, 69, 598657, 675995 Made in China OCS 00C Black : Ground Red: +VDC Blue: control output Grey: & Photocell control output Relay Contacts: Blue/White = common Black/White = N.C. Yellow/White = N.O. Connections Sensor Body 5 Attach Sensor Body to Cover Plate by aligning arrows and twist lock into place. Conference Room * Mask Full Mask 80º Mask * * Infrared Lens w/ Retainer Ring Installation Method Nut and Washer ( ea) Secure Cover Plate to the. Mounting Bolts () NOTE: *Only use a mask if the PIR sensor needs to be blocked. Only one mask should be installed at any given time. ATTENTION: All structural steps and electrical installation must be performed by qualified personnel in accordance with local and national building codes and electrical codes. Toute étape structurelle et installation électrique, doit être effectuée par un personnel qualifié, conformément aux codes du bâtiment, aux codes incendie et sécurité, et aux codes électriques, locaux et nationaux. Insert wiring through Mounting Bracket. Connect Building Wiring to Wiring Harness with Wire Nuts. Sensor Body Screw and mount the Twist-lock Cover Plate. Figure. Installation Diagram

M -S G L -67-0 A Sensor OCS 00C Setup Guide (Continued) OCS 00C Wiring Diagram 5A MAX IPCP PRO 550 Control Processor Dual Zone 00-0V ~ 50-60Hz Sensor w/ VDC Power Supply BUS ID Single Zone S B +V +S G S B ebus + V 7 PWR = 9W SWITCHED VDC 0W MAX TOTAL Tx Rx G TxRxG Tx Rx G TxRx G RTSCTS S G S G S G S G +V +S -S G ebus 5 6 8 5 6 7 8 5 6 7 8 G VDC ECM DIO8 ECM DIO8 ebus Control Module Sensor w/ VDC Power Supply DIGITAL I/O G 5 6 7 8 G Tx Rx G TxRxG Tx Rx G TxRx G RTSCTS COM +V (Red) Ground (Black).5 A MAX V IN PC -67-0 A S G S G S G S G IR/SERIAL E t PC Power Module Ground (Black) Control Signal # (Blue) Ground (Black) +V (Red) RELAYS Control Signal # (Blue) V.5 A MAX V 75 ma MAX Ground (Black) +V (Red) FLEX I/O IPCP PRO 550 LAN 00-05-A6-XX-XX-XX MAC: 00-05-A6-XX-XX-XX S/N: ####### E###### OCS 00C Sensor NOTE: The Ground dash line is optional. Control Signal # (Blue) OCS 00C Sensor OCS 00C Sensor Black Red Blue Gray Connections Ground + VDC control output and photocell control output NOTE: The gray wire is used when the control system needs to know when the area is adequately lit with natural light and when motion is detected (For example, automatic lighting through control system). Blue/ White Black/ White Yellow/ White Relay Contacts Common Normally closed when occupied Normally open when occupied NOTE: Relay contacts could be used to trigger third party devices, such as HVAC, based on occupancy. Figure 5. OCS 00C Wiring Diagram PC Wiring ATTENTION: Do not connect power until you have read the ATTENTIONS: notices on the next page. Ne branchez pas l alimentation avant d avoir lu les mises en garde «ATTENTIONS» de la page suivante. Remove power from the system before making any connections. Mettez le système hors tension avant d effectuer tout raccordement. The OCS 00C requires VDC. If the sensors are connected to a device that does not provide VDC:. Connect a VDC power source to the VDC input on the supplied PC power converter, using a -pole captive screw connector.. Wire the PC VDC -pole captive screw connector to the black and red wires on the OCS 00C. A VDC pass-through is available to power additional VDC devices. Power Source.5 A MAX V IN PC V.5 A MAX V 75 ma MAX Additional Devices Sensor PC Power Module

Troubleshooting Problem Possible Cause Test Result Sensor remains on. Constant noise. Reduce both green and red knobs by 5% and remove noise source. Move sensor to a less noisy area within the room. Sensor remains on too long. Timer setting is too high. Check dip switch settings. Reduce timer setting. Hallway traffic turns sensor on. Infrared sensor can see into the hallway. Put in timer test mode and walk the hallway. Move the sensor, so the sensor cannot see into the hallway. Safety Instructions For information on safety guidelines, regulatory compliances, EMI/EMF compatibility, accessibility, and related topics, see the Safety and Regulatory Compliance Guide, on the website, www.extron.com. FCC Class A Notice This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 5 of the FCC rules. The Class A limits provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause interference. This interference must be corrected at the expense of the user. NOTE: For more information on safety guidelines, regulatory compliances, EMI/EMF compatibility, accessibility, and related topics, see the Safety and Regulatory Compliance Guide on the website. Power Attentions ATTENTIONS: These products are intended for use with a UL Listed LPS type power source. Ces produits doivent être utilisés avec une source d alimentation de type LPS certifiée UL. Use of a non-lps or unlisted power supply will void all regulatory compliance certification. L utilisation d une source d alimentation non-listée ou non-listée LPS annulera toute certification de conformité réglementaire. Unless otherwise stated, the AC/DC adapters are not suitable for use in air handling spaces or in wall cavities. The power supply is to be located within the same vicinity as the AV processing equipment in an ordinary location, Pollution Degree, secured to the equipment rack within the dedicated closet, podium, or desk. Sauf mention contraire, les adaptateurs CA/CC ne conviennent pas à une utilisation dans les espaces d aération ou dans les cavités murales. La source d alimentation doit être placée à proximité de l équipement dans un emplacement ordinaire soumis à un degré de pollution de catégorie II, solidement fixé au rack d équipement d une baie technique, d un pupitre. The installation must always be in accordance with the applicable provisions of National Electrical Code ANSI/NFPA 70, article 75 and the Canadian Electrical Code part, section 6. Cette installation doit toujours être conforme aux dispositions applicables du Code américain de l électricité (National Electrical Code) ANSI/NFPA 70, article 75, et du Code canadien de l électricité, partie, section 6. The power supply shall not be permanently fixed to building structure or similar structure. La source d alimentation ne devra pas être fixée de façon permanente à la structure de bâtiment ou à d autres structures similaires. 5

Headquarters +800.6.9876 Inside USA/Canada Only USA - West USA - East +.7.9.500 +.99.850.000 +.7.9.57 FAX +.99.850.00 FAX Europe +800.987.667 Inside Europe Only +..5.00 +..5.050 FAX Asia +65.68.00 +65.68.66 FAX Japan +8..5.7655 +8..5.7656 FAX China +86..760.568 +86..760.566 FAX Middle East +97..99.800 +97..99.880 FAX Australia +6.8.8.6800 +6.8.85.5 FAX India 800.070.777 (Inside India Only) +9.80.055.777 +9.80.055.77 FAX 6 07 Electronics All rights reserved. All trademarks mentioned are the property of their respective owners. www.extron.com 68-55-5 Rev. A 08 7