TEST REPORT. Table of Contents

Similar documents
TEST REPORT. Table of Contents

TEST REPORT. Table of Contents

TEST REPORT. Table of Contents

TEST REPORT. Table of Contents

TEST REPORT. Product Name: Model No.: Applicant:

TEST REPORT. Product Name: Model No.: Applicant: Date of Receipt: Jul. 07, 2018

TEST REPORT. Product Name: HyperX Cloud Flight Wireless Gaming Headset USB Dongle Model No.: Cloud Flight, HXS-HSDG2 Applicant:

ELECTRONICS TESTING CENTER(ETC), TAIWAN

EN 55015: 2013 Clause Pass. EN 55015: 2013 Clause Pass. EN 55015: 2013 Clause Pass

ITUNER NETWORKS CORPORATION EMC REPORT Fremont Blvd. Fremont, CA

EMC TEST REPORT. Report No.: TS EME Model No.: 33XR-A Issued Date: Jan. 08, 2009

TEST SUMMARY. Prüfbericht - Nr.: Test Report No.: Seite 2 von 25. Page 2 of 25

1 SUMMARY OF STANDARDS AND RESULTS

SUZHOU MAILI ELECTRICAL APPLIANCE CO., LTD NO.666,JIANLIN RD, XUGUAN SUBAREA, SUZHOU HIGH-TECH ZONE

EMC TEST REPORT For. Shenzhen Ruideou Keji Youxian Gongsi. Shenzhen Ruideou Keji Youxian Gongsi

Test Report. Guangdong East Power Co., Ltd. Fully Automatic AC Voltage Regulator. Brand Name:

APPLICATION FOR EMC DIRECTIVE. On Behalf of. Shenzhen Qinhan Lighting Co., Ltd. led flood light. Trade Name:

Discontinuous Disturbance (Click) EN : 2011 Clause Pass Radiated Emission, 30MHz to 1000MHz

EMC TEST REPORT For MPP SOLAR INC Inverter/ Charger Model Number : PIP 4048HS

EMC TEST REPORT for SHENZHEN MUST ENERGY TECHNOLOGY CO., LTD

TEST SUMMARY. Prüfbericht - Nr.: Test Report No.: Seite 2 von 27. Page 2 of 27

EMC Test Report For Changzhou Airwheel Technology Co.,Ltd. Airwheel Model: A6S,A6,A6P,A6PS,A6T,A6TS

Harmonic Current emission EN :2014 Class A Pass. Voltage Fluctuation and Flicker EN :2013 Clause 5 Pass

EN :2007+A1:2011 Electromagnetic compatibility Emission standard for residential, commercial and light-industrial environments

EMC TEST REPORT. For. Switching Mode Power Adaptor. Model No.: 9W/14.4V/EU(18V/1.0A), 19W/14.4V/EU(12V/1.5A)

Overview of EMC Regulations and Testing. Prof. Tzong-Lin Wu Department of Electrical Engineering National Taiwan University

Discontinuous Disturbance (Click) EN :2006+A1:2009+A2:2011 Clause N/A** Radiated Emission, 30MHz to 1000MHz

TEST SUMMARY Seite 2 von 27. Prüfbericht - Nr.: Test Report No HARMONICS ON AC MAINS RESULT: Passed

EMC TEST REPORT For INNOKIN TECHNOLOGY CO., LIMITED. ITaste vv. Model No.: ITaste vv

Test Report GUANGDONG EAST POWER CO., LTD

Page: 1 of 20 EMC TEST REPORT EN55024:1998+A2:2003

EN 55022: 2010+AC:2011 Clause 6.1 Pass. Harmonic Current EN :2006+A1:2009+A2:2009 Class A N/A

EMC TEST REPORT For DONGHUA ELECTRIC STOCK CO., LTD. OF ZHEJIANG

C E R T I F I C A T I O N

Guangdong East Power Co., Ltd. Uninterruptible Power Systems

Shenzhen Toby Technology Co., Ltd. EMC Test Report. Report No.: TB-EMC Page: 1 of 20

Report for Excelsys EMC Measurements for 6Xgen Purchase Order: by Project Number EMT08J027

PT. SARANA KARYA SOLUSINDO.

Test Report. Ningbo Goldmore Industrial Co.,Ltd.

Prepared for Address. : KST DIGITAL TECHNOLOGY LIMITED : No.226, Pangu Street, Meixian, Meizhou, Guangdong. Prepared by

EMC standards. Presented by: Karim Loukil & Kaïs Siala

EMC TEST REPORT. Report No.: CE10-LIE040101E

TEST REPORT... 1 CONTENT...

EMC TEST REPORT. NORTE SIRIUS ENTERPRISE CO., LTD , Shin-Sheng St., Chung-Ho Dist, New Taipei City, Taiwan

EMC TEST REPORT for : DONGGUAN EVER DEVELOPMENT ELECTRONIC CO., Electronic calculator Model No.: KF15758

CE EMC Test Certification

9. Electrostatic Discharge Immunity Test (ESD)

Test Report Report No.: G150424B02-03EN Date: May. 07, 2015 Page 1 of 49

EMC TEST REPORT. ADDRESS : #2 Creation Rd. 4, Science-Based Ind. Park Hsinchu Taiwan, R.O.C.

T A B L E O F C O N T E N T S DESCRIPTION PAGE

C E R T I F I C A T I O N

APPLICATION FOR CERTIFICATION On Behalf of Futaba Corporation Radio Control Model No.:T10CG-2.4G FCC ID:AZPT10CG-24G Brand : Futaba

Report for Excelsys EMC Measurements for 4Xgen Purchase Order: Project Number EMT07J026 Rev. B

EMC TEST REPORT CE TEST REPORT. for Audio / Video receivers and associated equipment

ETSI EN V2.2.0 ( ) ETSI EN V2.1.1 ( ) TEST REPORT. United GULF GATE Co.

EMC TEST REPORT. For. Boardcon Technology Limited. MINI9G45 Computer on Module. Model No. : MINI9G45

EMC TEST REPORT for LEDELS LIGHTING CO., LTD. LED module Model No. : LL-F12T4815X6B

Declaration of Conformity (DoC)

EMC Testing Report. Dual-120CS. Yuan Hsun Electric Co., Ltd.

Contents. Report No.: EMC-CE-2114 Page: 2 of 39

EMC TEST REPORT. For MICRO-STAR INT'L CO.,LTD. USB Card Reader

CE TEST CERTIFICATION

TEST REPORT. Report No. : EM/2008/80003 Page : 1 of 54

EMC VERIFICATION SUMMARY Report No.: SZHH

EMC Test Report. Report Number: M030826

EMC Test Report FATEK AUTOMATION CORP. FATEK. FBs-TBOX N/A

TABLE OF CONTENTS 1. GENERAL DESCRIPTION OF EUT 3 2. GENERAL INFORMATION OF TEST CONDUCTED EMISSION TEST RADIATED EMISSION TEST 11

EMC TEST REPORT. Report No. : EM/2004/10096 Page : 1 of 19

CE/EMC TEST REPORT. For HK QNOVATOR TECHNOLOGY CO.,LIMITED GS02-M X1, BL02, GS01, GS01-M, GS02, GS03, GS04, GS05, GS06, GS07, GS08, GS09, GS10

EMC TEST REPORT. for. Coliy Technology Co.,Ltd. Fluxgate Gaussmeter

Declaration of Conformity.

EMC TEST REPORT For ShenZhen ZhangQing Electronic LTD poe tester Model No.: WS POE Tester/Detector Additional Model No: Please Refer to Page 8

Report No.: 9A042401C2 Page 1 of 36. Test Report EN : Prepared for

BS EN TESTS ON THE IT TOXIC GAS DETECTOR MODULE

CONFORMANCE TEST REPORT FOR EN /-6

CTS (NINGBO) TESTING SERVICE TECHNOLOGY INTERNATIONAL OPERATE ACCORDING TO ISO/IEC EMC TEST REPORT

EMC Test Report. Product. Model Number. Prepared for : Shenzhen top technology co., LTD Address : No 2.First Rd Of Lucky,Longgang Ping Shenzhen China

Test Report: 4R Champlain Street Dieppe, New-Brunswick Canada E4P 8L6. Model Number: Verification

EMC TEST REPORT. For PEAK ELECTRONIC(HUIZHOU)CO., LTD. DAB/FM radio Model No.: DB-318 Additional Model No.: DB-318B, DB-318C, DB-318R, DB-318U

EMC REPORT. ShenZhen KY Technology Co.,Ltd. No.369, BaoTian 1st RD, TieGang Industrial Park, Xixiang Town, Baoan District, ShenZhen, PRC.

C E R T I F I C A T I O N

C E R T I F I C A T I O N

CE TEST CERTIFICATION

EMC COMPLIANCE TEST REPORT

CE-EMC TEST REPORT. Prepared for : Kinglumi Co., Ltd. Bldg 3, Nangang 3nd Industrial Zone, Tangtou, Shiyan Town, Bao an District, Shenzhen City, China

AUSTRALIA TEST REPORT For. KLM Lighting Co., Limited. LED Down Light. Model No.: KLM-HP30WSN

TEST REPORT. Building 6,XinXinTian Industrial Park, XinSha Road, ShaJing, Baoan District, ShenZhen, China

EMC REPORT DONGGUAN FIT-WATCH CO., LTD. 18#,Hedong No.1 road,jinsha village,changan town, Dongguan City, Guangdong Province.

Global EMC Labs EMC / EMI Test Report

FCC 47 CFR PART 15 SUBPART B

Nemko Canada Inc., 303 River Road, R.R. 5, Ottawa, Ontario, Canada, K1V 1H2

CTS (NINGBO) TESTING SERVICE TECHNOLOGY INTERNATIONAL OPERATE ACCORDING TO ISO/IEC EMC TEST REPORT

EMC TEST REPORT. according to

Test Report. Apricus Solar Co., Ltd. Multi-Function Differential Controller

Test Report GUANGDONG EAST POWER CO., LTD

Test Report: 5R Champlain Street Dieppe, New Brunswick Canada E1A 1P6. Model Number: Verification

FCC DoC TEST REPORT To: PARTICLE INDUSTRIES, INC To: - Attn: Eric Attn: - Address: 1400 Tennessee St, #4 San Francisco, CA Address: -

r(oilgln TEST REPORT 'AGREB 6 %P\l Br EMC10001 sasa Gros, B.s"{h-$ INSTITUTE EMC and Safetv Laboratorv

EMC Testing Report. StarCam Genie N/A MICRO-STAR INT L CO., LTD.

Test Report. Product Name: Cable Modem Model No.: BEFCMU10 ver.3 FCC ID. : Q87-BEFCMU10V3

Transcription:

Page:2 of 35 Table of Contents 1. DOCUMENT POLICY AND TEST STATEMENT... 4 1.1 DOCUMENT POLICY...4 1.2 TEST STATEMENT...4 1.3 EUT MODIFICATION...4 2. DESCRIPTION OF EUT AND TEST MODE... 5 2.1 GENERAL DESCRIPTION OF EUT...5 2.2 DESCRIPTION OF EUT INTERNAL DEVICE...5 2.3 DESCRIPTION OF TEST MODE...5 3. DESCRIPTION OF APPLIED STANDARDS... 6 4. EMISSION TEST... 7 4.1 CONDUCTED EMISSION TEST FOR MAIN PORT...7 4.1.1 CONDUCTED EMISSION LIMIT...7 4.1.2 TEST EQUIPMENT...7 4.1.3 TEST SETUP...8 4.1.4 TEST PROCEDURE...8 4.1.5 DESCRIPTION OF SUPPORT UNIT...9 4.1.6 EUT OPERATING CONDITION...9 4.1.7 TEST RESULT...10 4.2 RADIATED EMISSION TEST...11 4.2.1 RADIATED EMISSION LIMIT...11 4.2.2 TEST EQUIPMENT...11 4.2.3 TEST SET-UP...12 4.2.4 TEST PROCEDURE...12 4.2.5 DESCRIPTION OF SUPPORT UNIT...13 4.2.6 EUT OPERATING CONDITION...13 4.2.7 TEST RESULT...14 5. ELECTROSTATIC DISCHARGE IMMUNITY TEST... 15 5.1 TEST EQUIPMENT...15 5.2 TEST PROCEDURE...15 5.3 TEST SET-UP...16 5.4 DESCRIPTION OF SUPPORT UNIT...17 5.5 EUT OPERATING CONDITION...17 5.6 TEST CONDITION AND PERFORMANCE CRITERION...17 5.7 SUMMARY OF TEST RESULT...18 6. RADIATED IMMUNITY TEST... 19 6.1 TEST EQUIPMENT...19 6.2 TEST PROCEDURE...19 6.3 TEST SETUP...20 6.4 DESCRIPTION OF SUPPORT UNIT...21 6.5 EUT OPERATING CONDITION...21 6.6 TEST CONDITION / PERFORMANCE CRITERIA...21 6.7 TEST RESULT...21 7. ELECTRICAL FAST TRANSIENT / BURST IMMUNITY TEST... 22

Page:3 of 35 7.1 TEST EQUIPMENT...22 7.2 TEST PROCEDURE...22 7.3 TEST SET-UP...23 7.4 DESCRIPTION OF SUPPORT UNIT...23 7.5 EUT OPERATING CONDITION...23 7.6 TEST CONDITION / PERFORMANCE CRITERIA...24 7.7 SUMMARY OF TEST RESULT...24 8. INDUCED RF FIELDS (CONDUCTED SUSCEPTIBILITY) TEST... 25 8.1 TEST EQUIPMENT...25 8.2 TEST PROCEDURE...25 8.3 TEST SET-UP...26 8.4 DESCRIPTION OF SUPPORT UNIT...26 8.5 EUT OPERATING CONDITION...26 8.6 TEST CONDITION / PERFORMANCE CRITERIA...27 8.7 SUMMARY OF TEST RESULT...27 9. POWER FREQUENCY MAGNETIC-FIELD TEST... 28 9.1 TEST EQUIPMENT...28 9.2 TEST PROCEDURE...28 9.3 TEST SET-UP...28 9.4 DESCRIPTION OF SUPPORT UNIT...28 9.5 EUT OPERATING CONDITION...29 9.6 TEST CONDITION / PERFORMANCE CRITERIA...29 9.7 SUMMARY OF TEST RESULT...29 10. PHOTOS OF TESTING... 30 11. TERMS OF ABRIVATION... 35

Page:4 of 35 1. DOCUMENT POLICY AND TEST STATEMENT 1.1 DOCUMENT POLICY - The report shall not be reproduced except in full, without the written approval of SRT Lab, Inc. - The report must not be used by the applicant to claim that the product is endorsed by NVLAP, TÜV, NEMKO and SRT. - The NVLAP logo applies only to the applicable standards specified in this report. 1.2 TEST STATEMENT - The test results in the report apply only to the unit tested by SRT Lab. - There was no deviation from the requirements of test standards during the test. - AC power source, 230 VAC/50 Hz, was used during the test. - The EN 61000-3-2 edition 2:2000(Harmonic test) and EN 61000-3-3:1995+A1:2001 (Flicker test) are not included in the scope of NVLAP logo usage. - The EN 61000-3-2 edition 2:2000(Harmonic test) and EN 61000-3-3:1995+A1:2001 (Flicker test) are included in the scope of TÜV, NEMKO and SRT logo usage. 1.3 EUT MODIFICATION - No modification in SRT Lab.

Page:5 of 35 2. DESCRIPTION OF EUT AND TEST MODE 2.1 GENERAL DESCRIPTION OF EUT PRODUCT PCI Express esata and IDE /CF/PCMCIA Bridge MODEL NO. PE-100, PE-100N, PE-102, PE-105N, ST-123, ST-123CF, ST-101L POWER SUPPLY DC from PC CABLE N/A TYPE Prototype NOTE: The EUT has seven model numbers as below on market. They are identical in all aspects except for the number of material. For more detailed information, please refer to the EUT s specification or user s manual provided by manufacturer. 2.2 DESCRIPTION OF EUT INTERNAL DEVICE DEVICE BRAND / MAKER MODEL # REMARK N/A NOTE : 1. The highest clock is 25MHz. 2. Frequency range to be measured. Radiated emission is 30MHz to 1GHz. 2.3 DESCRIPTION OF TEST MODE N/A (It is only applicable to more than one test mode.)

Page:6 of 35 3. DESCRIPTION OF APPLIED STANDARDS The EUT is a kind of ITE interface device and according to the specifications provided by the applicant, it must comply with the requirements of the following standards: EN 55022:1998+A1:2000+A2:2003, Class B EN 61000-3-2 edition 2:2000 EN 61000-3-3:1995+A1:2001 EN 55024:1998+A1:2001+A2:2003 - IEC 61000-4-2:1995+A1:1998+A2:2001 - IEC 61000-4-3:2002+A1:2002 - IEC 61000-4-4:1995+A1:2001+A2:2001 - IEC 61000-4-5:1995+A1:2001 - IEC 61000-4-6:2004 - IEC 61000-4-8:1993+A1:2001 - IEC 61000-4-11:1994+A1:2001 But the standards of EN 61000-3-2, EN 61000-3-3, IEC 61000-4-5 and IEC 61000-4-11 were not measured, because the EUT s power source is DC from PC. All tests have been performed and recorded as the above standards.

Page:7 of 35 4. EMISSION TEST 4.1 CONDUCTED EMISSION TEST FOR MAIN PORT 4.1.1 CONDUCTED EMISSION LIMIT Class A (dbµv) Class B (dbµv) FREQUENCY (MHz) Quasi-peak Average Quasi-peak Average 0.15-0.5 79 66 66-56 56-46 0.5-5.0 73 60 56 46 5.0-30.0 73 60 60 50 NOTE: 1. The lower limit shall apply at the transition frequencies. 2. The limit decreases in line with the logarithm of the frequency in the range of 0.15 to 0.50 MHz. 4.1.2 TEST EQUIPMENT The following test equipment was used for the test: EQUIPMENT/ FACILITIES EMI TEST RECEIVER SPECIFICATIONS MANUFACTURER 9 khz TO 30 MHz LISN (for EUT) 50 µh, 50 ohm FCC LISN (for Peripheral) 50 ohm TERMINATOR COAXIAL CABLE 50µH, 50 ohm ROHDE & SCHWARZ FCC 50 ohm HP 3m SUNCITY MODEL#/ SERIAL# ESHS30/ 826003/008 FCC-LISN-50-25-2 / 01017 FCC-LISN-50-25-2 / 01018 11593A/ 2 J400/ 3M ISOLATION TRANSFORMER N/A APC AFC-11015/ F102040016 FILTER 2 LINE, 30A FIL.COIL GROUND PLANE GROUND PLANE 2.3M (H) x 2.4M (W) 2.4M (H) x 2.4M (W) FC-943/ 771 DUE DATE OF CAL. & CAL. CENTER AUG. 2005 NOV. 2005 NOV. 2005 OCT. 2005 JUL. 2005 SRT N/A N/A SRT N/A N/A SRT N/A N/A NOTE: The calibration interval of the above test equipment is one year and the calibrations are traceable to NML/ROC and NIST/USA.

Page:8 of 35 4.1.3 TEST SETUP To Utility Power Isolation Transformer EMI TEST Receiver Coaxial Cable Filter LISN EUT LISN Support Units NOTE: 1. The EUT was put on a wooden table with 0.8m height above ground plane, and 0.4m away from reference ground plane (> 2mx2m). 2. For the actual test configuration, please refer to the photos of testing. 3. The serial no. of the LISN connected to EUT is 01017. 4. The serial no. of the LISN connected to support units is 01018. 4.1.4 TEST PROCEDURE The EUT was tested according to the requirement of EN 55022:1998+A1:2000+A2:2003. The frequency spectrum from 0.15 MHz to 30 MHz was investigated. The LISN used was 50Ω/50µH as specified. All readings were quasi-peak and average values with 10 khz resolution bandwidth of the test receiver. The EUT system was operated in all typical methods by users. Both lines of the power mains of EUT were measured and the cables connected to EUT and support units were moved to find the maximum emission levels for each frequency. First, find the margin or higher points at least 6 points by software, then use manual to find the maximum data. The procedure is referred on the test procedure of SRT LAB.

Page:9 of 35 4.1.5 DESCRIPTION OF SUPPORT UNIT The EUT was configured by the requirement of EN 55022:1998+A1:2000+A2:2003. All interface ports were connected to the appropriate support units via specific cables. The support units and cables are listed below. NO DEVICE BRAND MODEL # CABLE 1 MONITOR SAMSUNG PG17IS 1.8m unshielded power cord 1.5m shielded data cable 2 PRINTER EPSON STYLUS C20SX 1.5m unshielded power cord 1.6m shielded data cable 3 MODEM ACEEX DM-1414 1.5m unshielded DC power cable 1.2m unshielded data cable 4 KEYBOARD ACER 6312-TA4C/6 1.5m shielded data cable 5 MOUSE COMPAQ M-S34 1.5m shielded data cable NOTE: For the actual test configuration, please refer to the photos of testing. 4.1.6 EUT OPERATING CONDITION 1. Under Windows XP ran EMITEST, Mediaplayer and XCOPY programs. 2. EUT sent "H" pattern or accessed the following peripherals directly: - Color Monitor - RS232 - Keyboard - Mouse - Printer - FDD - HDD 3. XCOPY :loop XCOPY C:\test E:\/s/y Go to loop

Page:10 of 35 4.1.7 TEST RESULT Temperature: 26 C Humidity: 63%RH Ferquency Range: 0.15 30 MHz Tested Mode: N/A Receiver Detector: Q.P. and AV. Tested By: Oscar Lu Tested Date: July 13, 2005 Power Line Measured : Line Freq. (MHz) Correct. Factor (db) Reading Value (dbµv) Emission Level (dbµv) Limit (dbµv) Margin (db) Q.P. AV. Q.P. AV. Q.P. AV. Q.P. AV. 0.150 0.30 54.56 28.02 54.86 28.32 66.00 56.00-11.14-27.68 0.153 0.30 53.70 25.77 54.00 26.07 65.82 55.82-11.82-29.75 0.533 0.24 34.10 31.34 34.34 31.58 56.00 46.00-21.66-14.42 9.121 0.23 42.20 41.05 42.43 41.28 60.00 50.00-17.57-8.72 9.263 0.23 41.28 39.42 41.51 39.65 60.00 50.00-18.49-10.35 17.819 0.33 40.32 39.65 40.65 39.98 60.00 50.00-19.35-10.02 Power Line Measured : Neutral Freq. (MHz) Correct. Factor (db) Reading Value (dbµv) Emission Level (dbµv) Limit (dbµv) Margin (db) Q.P. AV. Q.P. AV. Q.P. AV. Q.P. AV. 0.150 0.30 54.80 27.88 55.10 28.18 66.00 56.00-10.90-27.82 0.153 0.30 53.80 26.72 54.10 27.02 65.82 55.82-11.72-28.80 0.533 0.24 33.72 31.65 33.96 31.89 56.00 46.00-22.04-14.11 9.831 0.23 39.34 31.23 39.57 31.46 60.00 50.00-20.43-18.54 9.974 0.23 39.82 35.55 40.05 35.78 60.00 50.00-19.95-14.22 18.956 0.30 44.18 40.08 44.48 40.38 60.00 50.00-15.52-9.62 NOTE : 1. Measurement uncertainty is +/-1.32dB 2. Emission level = Reading valus + Correction factor 3. Correction Factor = Cable loss + Insertion loss of LISN 4. Margin value = Emission level - Limit 5. The emission of other frequencies were very low against the limit. 6. "-": The Quasi-peak reading value also meets average limit and measurement with the average detector is unnecessary.

Page:11 of 35 4.2 RADIATED EMISSION TEST 4.2.1 RADIATED EMISSION LIMIT FREQUENCY (MHz) Class A (at 10m) Class B (at 10m) dbµv/m dbµv/m 30 230 40 30 230-1000 47 37 NOTE: 1. The lower limit shall apply at the transition frequencies. 2. Emission level (dbµv/m) = 20 log Emission level (µv/m). 4.2.2 TEST EQUIPMENT The following test equipment was used during the radiated emission test: EQUIPMENT/ FACILITIES EMI TEST RECEIVER BI-LOG ANTENNA OATS COAXIAL CABLE SPECIFICATIONS MANUFACTURER 9 khz TO 2.75 GHz 25 MHz TO 2 GHz ROHDE & SCHWARZ EMCO MODEL#/ SERIAL# ESCS30/ 830245/012 3143/ 9509-1141 DUE DATE OF CAL. & CAL. CENTER OCT. 2005 SEP. 2005 SRT 3 10 M MEASUREMENT SRT SRT-1 DEC. 2005 SRT 25M SUNCITY FILTER 2 LINE, 30A FIL.COIL FREQUENCY CONVERTER N/A APC J400/ 25M FC-943/ 869 AFC-2KBB/ F100030031 AUG. 2005 SRT N/A AUG. 2005 SRT NOTE: 1. The calibration interval of the above test equipment is one year and the calibrations are traceable to NML/ROC and NIST/USA. 2. The Open Area Test Site (SRT-1) is registered by FCC with No. 90957 and VCCI with No. R-1081. 3. The Open Area Test Site (SRT-2) is registered by FCC with No. 98458 and VCCI with No. R-1168.

Page:12 of 35 4.2.3 TEST SET-UP Power Cable EUT Turn Table 0.8 m 1m 4m Coaxial Cable 3/10m Filter To Utility Power EMI Receiver Ground Plane NOTE: 1. The EUT system was put on a wooden table with 0.8m heights above a ground plane. 2. For the actual test configuration, please refer to the photos of testing. 4.2.4 TEST PROCEDURE The EUT was tested according to the requirement of EN 55022:1998+A1:2000+A2:2003. The measurements were made at an open area test site with 10 meter measurement distance under 1 GHz and with 3m distance above 1GHz. The frequency spectrum measured from 30 MHz to 1 GHz. All readings were quasi-peak values with 120 khz resolution bandwidth of the test receiver. Above 1 GHz, the measurements were made at an open area test site with 3 meter measurement distance and all readings were peak or average values with 1 MHz resolution bandwidth of the test receiver. The EUT system was operated in all typical methods by users. The cables connected to EUT and support units were moved to find the maximum emission levels for each frequency. First, find the margin or higher points at least 6 points by software, then use manual to find the maximum data. The procedure is referred on the test procedure of SRT LAB.

Page:13 of 35 4.2.5 DESCRIPTION OF SUPPORT UNIT Same as section 4.1.5 of this report. 4.2.6 EUT OPERATING CONDITION Same as section 4.1.6 of this report.

Page:14 of 35 4.2.7 TEST RESULT Temperature: 26 C Humidity: 66 %RH Ferquency Range: 30 1000 MHz Measured Distance: 10m Receiver Detector: Q.P. Tested Mode: N/A Tested By: Oscar Lu Tested Date: July 13, 2005 Antenna Polarization:Horizontal Cable Antenna Reading Emission Frequency Limit Margin Loss Factor Data Level (MHz) (dbµv/m) (db) (db) (db/m) (dbµv) (dbµv/m) AZ( ) EL(m) 749.9760 5.19 21.35 8.4 34.9 37.0-2.1 269.0 1.50 600.0000 4.60 19.60 9.6 33.8 37.0-3.2 74.0 3.50 527.9860 4.26 18.65 9.7 32.6 37.0-4.4 185.0 3.10 431.3980 3.77 16.85 12.4 33.0 37.0-4.0 266.0 4.00 335.9920 3.20 14.58 17.0 34.8 37.0-2.2 20.0 2.28 239.9900 2.71 11.67 14.1 28.5 37.0-8.5 140.0 4.00 Antenna Polarization:Vertical Cable Antenna Reading Emission Frequency Limit Margin Loss Factor Data Level (MHz) (dbµv/m) (db) (db) (db/m) (dbµv) (dbµv/m) AZ( ) EL(m) 199.9400 2.48 9.79 12.3 24.6 30.0-5.4 180.0 1.00 239.9920 2.71 11.67 13.5 27.9 37.0-9.1 152.0 1.00 299.6600 3.02 13.67 11.9 28.6 37.0-8.4 236.0 1.00 335.9900 3.20 14.58 16.2 34.0 37.0-3.0 15.0 1.00 366.1740 3.38 15.35 10.0 28.7 37.0-8.3 37.0 1.00 431.2722 3.77 16.85 11.4 32.0 37.0-5.0 247.0 1.25 NOTE : 1. Measurement uncertainty is +/-2dB. 2. "*": Measurement does not apply for this frequency. 3. Emissiom Level = Reading Value + Ant. Factor + Cable Loss. 4. The field strength of other emission frequencies were very low against the limit.

Page:15 of 35 5. ELECTROSTATIC DISCHARGE IMMUNITY TEST 5.1 TEST EQUIPMENT EQUIPMENT / FACILITIES ESD SIMULATOR HCP (1.6M x 0.8M) VCP (0.5M x 0.5M) GROUND PLANE (3.4M x 2.4M) MANUFACTURER NOISEKEN SRT SRT MODEL # / SERIAL # ESS-100L(A)/TC-815P/ 8099C02238/7099C02 WITH TWO 470k OHM CABLE WITH TWO 470k OHM CABLE DUE DATE OF CAL. & CAL. CENTER OCT. 2005 N/A N/A SRT N/A N/A NOTE: The calibration interval of the above test equipment is one year and the calibrations are traceable to NML/ROC and NIST/USA. 5.2 TEST PROCEDURE According to IEC/EN 61000-4-2:1995+A1:1998+A2:2001

Page:16 of 35 5.3 TEST SET-UP ESD Gun Vertical Coupling Plane 10 cm Insulating Support EUT System 470kΩ Horizontal Coupling Plane Wooden Table 470kΩ Return Cable Ground Reference Plane NOTE : 1. The wooden table should be 0.8m high for table top EUT and 0.1m for floor-standing EUT. 2. For the actual test configuration, please refer to the photos of testing. 3. A distance of 1m minimum was provided between EUT and walls / other metallic structure.

Page:17 of 35 5.4 DESCRIPTION OF SUPPORT UNIT Same as section 4.1.5 of this report. 5.5 EUT OPERATING CONDITION Same as section 4.1.6 of this report. 5.6 TEST CONDITION AND PERFORMANCE CRITERION 1. Test condition (1) R-C Network : 330 Ω, 150 pf (2) Test level: Air Discharge : ±2kV, ±4kV, ±8kV Contact discharge : ±2kV, ±4kV HCP discharge : ±2kV, ±4kV VCP discharge : ±2kV, ±4kV (3) Discharge mode : Single discharge (4) Discharge period : at least 1 s (5) Discharge polarity : Positive and Negative (6) Number of discharge : Minimum 50 times at each test point of contact discharge and at least 200 times of discharge to EUT in total. Minium 10 times at each test area of air discharge selected. 2. Standard requirement : Criterion B 3. Performance criterion (1) Criterion A : Normal performance during test (2) Criterion B : Temporary degradation or loss of function or performance which is self-recoverable (3) Criterion C : Temporary degradation or loss of function or performance which requires operator intervention system reset

Page:18 of 35 5.7 SUMMARY OF TEST RESULT Temperature: 27 C Humidity: 65% RH Tested Mode: N/A Tested By: Oscar Lu Atmospheric Air Pressure: 101.2 kpa Tested Date: July 12, 2005 Test Result: Criterion A pass SEVERITY LEVEL AIR DISCHARGE COUPLING MODE & TEST OBSERVATION CONTACT DISCHARGE HCP VCP ±2kV A A A A ±4kV A A A A ±8kV A NR NR NR NOTE: Description of test observation: A: There was no change compared with initial operation during the test. NR: No requirement Description of test points: 1. Bracket of EUT. 2. LED. 3. Button of EUT. 4. HCP. 5. VCP.

Page:19 of 35 6. RADIATED IMMUNITY TEST 6.1 TEST EQUIPMENT EQUIPMENT / FACILITIES SIGNAL GENERATOR ANTENNA FIELD SENSOR POWER AMPLIFIER AMPLIFIER DUAL DIRECTIONAL COUPLER ISOTROPIC E FIELD PROBE MANUFACTURER HP SCHAFFNER CHASE AMPLIFIER RESEARCH AMPLIFIER RESEARCH A.R. A.R. A.R. MODEL # / SERIAL # 8648D/ 3847M00637 CBL6141A / 4181 FP2000/ 28499 100W1000M1/ 19509 50S1G4A/ 308703 DC7420/ 308626 FP4080 KIT/ 308105 POWER SENSOR BOONTON 51011EMC / 31181 POWER SENSOR BOONTON 51011EMC / 31184 DUAL DIRECTIONAL COUPLER ANECHOIC CHAMBER V/M MONITOR MONITOR CCD A.R. SRT A.R. SHIN TOPVIEW DC6080/ 25755 A05/ SRT005 FM2000/ 15970 SI-609/ 905130 N/A/ 95113762 DUE DATE OF CAL. & CAL. CENTER MAY. 2006 AGLIENT SEP. 2005 SRT DEC. 2005 MAY 2006 MAY 2006 A.R. MAR. 2006 APR. 2006 A.R. NOV. 2005 JUN. 2006 JUN. 2006 OCT. 2005 SRT N/A N/A N/A ABSORBER ETS N/A N/A COAXIAL CABLE COAXIAL CABLE TIME SUNCITY LMR400/ 50CM J400-12-2NP/ #12M AUG. 2005 SRT MAR. 2006 SRT NOTE: The calibration interval of the above test equipment is one year and the calibrations are traceable to NML/ROC and NIST/USA. 6.2 TEST PROCEDURE According to IEC/EN 61000-4-3:2002+A1:2002

Page:20 of 35 6.3 TEST SETUP Absorber Sensor 1.5m Absorber 0.8 m EUT Wooden table CCD Coaxial Cable 3 m Power Amplifier Signal Generator V/M Monitor Optical Fiber Monitor NOTE : 1. The wooden table should be 0.8m high for table top EUT and 0.1m for floor-standing EUT. 2. For the actual test configuration, please refer to the photos of testing. balun to Absorber/Tile 1.1m door Ant. 2.75m Absorber Location 1.5m 2.2m 1.85m 0.24m chamber (7m x 3m x 3m)

Page:21 of 35 6.4 DESCRIPTION OF SUPPORT UNIT Same as section 4.1.5 of this report. 6.5 EUT OPERATING CONDITION Same as section 4.1.6 of this report. 6.6 TEST CONDITION / PERFORMANCE CRITERIA 1. Test condition (1) Source voltage and frequency : 230V/50Hz, single phase (2) Sweeping frequency : 80MHz 1 GHz (3) Test level : 3V/m, the frequncy step is 1% (4) The four sides of EUT are tested : front, rear, left, right (5) Modulation : 80%AM, 1kHz Dwell time for each frequency is 3 sec. (6) Antenna Polarization : Horizontal and Vertical (7) Standard requirement : Criterion A 2. Performance criterion (1) Criterion A : Normal performance during test (2) Criterion B : Temporary degradation or loss of function or performance which is self-recoverable. (3) Criterion C : Temporary degradation or loss of function or performance which requires operator intervention system reset. 6.7 TEST RESULT Temperature: 27 C Humidity: 67 % RH Tested Mode: N/A Tested By: Oscar Lu Tested Date: July 12, 2005 Test Result : Criterion A pass FREQUENCY LEVEL MODULATION DIRECTION TEST RESULT (CRITERION) H V 80MHz - 1GHz 3V/m 80%AM, 1kHz FRONT A A 80MHz - 1GHz 3V/m 80%AM, 1kHz REAR A A 80MHz - 1GHz 3V/m 80%AM, 1kHz LEFT A A 80MHz - 1GHz 3V/m 80%AM, 1kHz RIGHT A A NOTE: Description of test observation: A: There was no change compared with initial operation during the test.

Page:22 of 35 7. ELECTRICAL FAST TRANSIENT / BURST IMMUNITY TEST 7.1 TEST EQUIPMENT EQUIPMENT / FACILITIES EFT GENERATOR CLAMP GROUND PLANE 2M x 3M MANUFACTURER HAEFELY HAEFELY MODEL # / SERIAL # PEFT-JUNIOR / 583-333-122 TRENCH / 080421-12 DUE DATE OF CAL & CAL CENTER APR. 2006 N/A SRT N/A N/A 7.2 TEST PROCEDURE According to IEC/EN 61000-4-4:1995+A1:2001+A2:2001

Page:23 of 35 7.3 TEST SET-UP Power Auxiliary Equipment EUT Auxiliary Equipment Clamp I/O and communication ports EFT Wave Generator Load EUT EFT Wave Power Cable Generator Auxiliary Equipment Power supply ports NOTE : 1. The EUT system was put on a wooden table with 0.8m height for table top EUT and 0.1m for floor-standing EUT above ground reference plane. 2. For the actual test configuration, please refer to the photos of testing. 3. The minimum distance between the EUT and all other conductive structure was more than 0.5m. 4. The minimum distance between the coupling plates of the coupling clamps (if used) and all over conductive structures, except the ground plane beneath the coupling clamp and beneath the EUT was more than 0.5m. 5. The power cable connecting EUT was controlled under 1m. 7.4 DESCRIPTION OF SUPPORT UNIT Same as section 4.1.5 of this report. 7.5 EUT OPERATING CONDITION Same as section 4.1.6 of this report.

Page:24 of 35 7.6 TEST CONDITION / PERFORMANCE CRITERIA 1. Test condition (1) Source voltage and frequency : 230V/50Hz, single phase (2) Pulse risetime and duration : 5ns / 50ns (3) Pulse repetition : 5kHz (4) Polarity : Positive Polarization and Negative Polarization (5) Burst duration and period : 15ms / 300ms (6) Test duration : 61sec each line (7) Time between test : 10Sec (8) Severity levels :Power Line ±1kV Signal/Control Line ±0.5kV (9) Standard requirement : Criterion B 2. Performance criterion (1) Criterion A : Normal performance during test (2) Criterion B : Temporary degradation or loss of function or performance which is self-recoverable. (3) Criterion C : Temporary degradation or loss of function or performance which requires operator intervention system reset. 7.7 SUMMARY OF TEST RESULT Temperature: 26 C Humidity: 66% RH Tested Mode: N/A Tested By: Oscar Lu Atmospheric Air Pressure: 101.2 kpa Tested Date: July 12, 2005 Test Result : Criterion A pass Voltage 1kV Polarity + - L1 A A Test Result L2 A A GND A A Signal/Control Line N/A N/A NOTE: Description of test observation: A: There was no change compared with initial operation during the test. N/A: Not applicable, as the signal/control line used in typical is less than 3 m.

Page:25 of 35 8. INDUCED RF FIELDS (CONDUCTED SUSCEPTIBILITY) TEST 8.1 TEST EQUIPMENT EQUIPMENT / FACILITIES EM INJECTION CLAMP MANUFACTURER FCC MODEL # / SERIAL # F-203I-23mm/ 110 DUE DATE OF CAL. & CAL. CENTER MAY 2006 FINAL TEST BE USED POWER LINE CDN POWER LINE CDN SIGNAL LINE CDN SIGNAL LINE CDN SIGNAL LINE CDN POWER LINE CDN SIGNAL GENERATOR POWER AMPLIFIER DUAL DIRECTION COULPER POWER METER SIGNAL LINE CDN POWER LINE CDN T2 COAXIAL CABLE COAXIAL CABLE COAXIAL CABLE FCC FCC FCC FCC FCC FCC R&S A.R. A.R. BOONTON FCC FCC EM-TEST ALPHA TIME TIME FCC-801-M5-32A/ 9812 FCC-801-M1-32A/ 9820 FCC-801-T2/ 9830 FCC-801-T6/ 9832 FCC-801-T4/ 9831 FCC-801-M2-32A/ 9840 SMY01 841104/019 150A100A/ 19553 DC2600/ 25893 4232A/ 105302 FCC-801-S25/ 9845 FCC-801-M3-32A/ 9874 ATT6/75/ 1001-40 RG-214/U #1M LMR-400/ #2M LMR-400/ #2M MAY 2006 MAY 2006 MAY 2006 MAY 2006 AUG. 2005 NOV. 2005 JUN. 2006 OCT. 2005 AUG. 2005 NOV. 2005 MAY 2006 MAY 2006 N/A AUG. 2005 SRT AUG. 2005 SRT AUG. 2005 SRT X X X X X X X X X 8.2 TEST PROCEDURE According to IEC/EN 61000-4-6:2004

Page:26 of 35 8.3 TEST SET-UP (1) For CDN injection : EUT Coaxial SIGNAL GENERATOR Cable Power Amplifier T2 CDN Auxiliary Equipment (2) For Clamp injection : EUT Monitoring Probe SIGNAL GENERATOR Coaxial Cable Power Amplifier T2 Injection Clamp Receiver Auxiliary Equipment NOTE : 1. The EUT system was put on a wooden table with 0.1m height above ground. 2. For the actual test configuration, please refer to the photos of testing. 3. The distance between CDN(Clamp) and EUT was controlled between 0.1m and 0.3m. 4. The model no. of the CDN connected to EUT is FCC-801-M3-32A. 8.4 DESCRIPTION OF SUPPORT UNIT Same as section 4.1.5 of this report. 8.5 EUT OPERATING CONDITION Same as section 4.1.6 of this report.

Page:27 of 35 8.6 TEST CONDITION / PERFORMANCE CRITERIA 1. Test condition (1) Source voltage and frequency : 230 V/ 50 Hz, single phase (2) Sweeping frequency : 150 khz 80 MHz (3) Test level : 3 V, the frequency step is 1% (4) Modulation : AM 80%, 1 khz (5) Dwell time for each frequency : 3 sec (6) Standard requirement : Criterion A 2. Performance criterion (1) Criterion A : Normal performance during test (2) Criterion B : Temporary degradation or loss of function or performance which is self-recoverable (3) Criterion C : Temporary degradation or loss of function or performance which requires operator intervention system reset 8.7 SUMMARY OF TEST RESULT Temperature: 28 C Humidity: 62% RH Tested Mode: All Tested By: Oscar Lu Tested Date: July 12, 2005 Test Result : Criterion A pass FREQUENCY LEVEL MODULATION INJECTION METHOD TEST RESULT (CRITERION) 150kHz - 80MHz 3V 80% AM, 1 khz M3 A NOTE: Description of test observation: A: There was no change compared with initial operation during the test.

Page:28 of 35 9. POWER FREQUENCY MAGNETIC-FIELD TEST 9.1 TEST EQUIPMENT EQUIPMENT / FACILITIES MANUFACTURER MODEL # / SERIAL # DUE DATE OF CAL. & CAL. CENTER MAGNETIC FIELD TESTER HAEFELY MAG 100.1/ 080.015-04 JAN. 2006 SRT MAGNETIC FIELD COIL HAEFELY MAG 100.1/ 080.015-04 JAN. 2006 SRT MAGNETIC FIELD METER F.W.BELL 4090/ 2000921 MAR. 2006 ITRI 9.2 TEST PROCEDURE According to IEC/EN 61000-4-8:1993+A1:2001 9.3 TEST SET-UP Magnetic Coil EUT Test Generator Frequency Converter NOTE : 1. The EUT system was put on a wooden table with 0.8m height above ground. 2. For the actual test configuration, please refer to the photos of testing 3. 1A/m = 12.56mG, 3A/m = 37.68mG, 10A/m = 125.6mG, 9.4 DESCRIPTION OF SUPPORT UNIT Same as section 4.1.5 of this report.

Page:29 of 35 9.5 EUT OPERATING CONDITION Same as section 4.1.6 of this report. 9.6 TEST CONDITION / PERFORMANCE CRITERIA 1. Test condition (1) Test axis : X, Y and Z axes (2) Test time :5 min / each axis (3) Field strength : 3 A/m (4) Standard requirement : Criterion A 2. Performance criterion (1) Criterion A : Normal performance during test (2) Criterion B : Temporary degradation or loss of function or performance which is self-recoverable (3) Criterion C : Temporary degradation or loss of function or performance which requires operator intervention system reset 9.7 SUMMARY OF TEST RESULT Temperature: 28 C Humidity: 66% RH Tested Mode: N/A Tested By: Oscar Lu Frequency of Magnetic Field: 50Hz, 60Hz Tested Date: July 12, 2005 Test Result : Criterion A pass ORIENTATION FIELD STRENGTH NOTE: Description of test observation: A: There was no change compared with initial operation during the test. TEST RESULT (CRITERION) X 3 A/m A Y 3 A/m A Z 3 A/m A

Page:30 of 35 10. PHOTOS OF TESTING - Conducted test

Page:31 of 35 - Radiated test

Page:32 of 35 - Electrostatic discharge immunity test - Electrical fast transient / burst immunity test

Page:33 of 35 - Radiated immunity test

Page:34 of 35 - Inducted RF fields (conducted susceptibility) test - Power frequency magnetic-field test

Page:35 of 35 11. TERMS OF ABRIVATION AV. AZ( ) Correct. EL(m) EUT Horiz. LISN NSA Q.P. SRT Lab Vert. Average detection Turn table azimuth Correction Antenna height (meter) Equipment Under Test Horizontal direction Line Impedance Stabilization Network Normalized Site Attenuation Quasi-peak detection Testing Laboratory, Inc. Vertical direction