RECOMMENDED INSTALLATION PROCEDURE LEVEL 3

Similar documents
RECOMMENDED INSTALLATION PROCEDURE LEVEL 3

RECOMMENDED INSTALLATION PROCEDURE LEVEL 3

Butyl Flash. Installation Instructions. Prep & General Conditions

WindowSeal. Installation Instructions. Prep & General Conditions

All Window Installation Instruction

TYPAR WEATHER PROTECTION SYSTEM TABLE OF CONTENTS. SPECIAL INSTALLATION CONSIDERATIONS Stucco** Brick** Stone Veneer** Wood Siding**

Providing 3 Layers of Protection

DuPont Flashing Systems Commercial Installation Guidelines

Eagle clad double-hung window installation instructions

Tools required by installer: Materials required by installer:

Read guide from beginning to end before starting installation. Read all warnings and cautions during unit installation.

Installation Guidelines For ALUMINUM M-SERIES 3 PANEL SLIDING DOOR

ADVANCED WATER AND MOISTURE BARRIER SYSTEM

Installation Guidelines For Quaker Window Products Aluminum flange fin sub sill & receptor system using a T mulled twin window unit.

3M Air and Vapour Barrier 3015 Technical guide

Installation Guidelines. Next Dimension. Single Hung / Single Hung Fixed / Double Hung / Sliding Window / Fixed Window

Fold-A-Way Patio Door ASSEMBLY & INSTALLATION GUIDE

Self-Adhering Reflective Sheet Membrane

Installation Guide. for E-Series/Eagle Clad Hinged Inswing French Door

Show them you're an InstallationMaster, and watch your business grow. InstallationMasters Training Manual Addendum Level RLC-1

ForceField Air & Water Barrier System. installation instructions

DOOR INSTALLATION GUIDE WOOD FRAMING New Construction

INSTALLATION GUIDELINES: X25 SERIES using perimeter installation fin

Best Materials LLC distributes backer rod, caulking and sealants for all types of EIFS joints and penetration sealing applications.

DuPont Flashing Systems Installation Guidelines. Integral Flanged Door Before water-resistive. Version 2

INSTALLATION INSTRUCTIONS DOUBLE-HUNG WINDOW WITH FINS

Installation of Fiberglass Windows

Features & Benefits: For Use with OSI QUAD Window & Door System. Recommended For:

INSTALLATION GUIDE WOOD PIVOTING CIRCLE/ OVAL

DuPont Tyvek Fluid Applied Flashing Commercial Installation Guidelines

Installation Guide for E-Series/Eagle Clad Mechanically Fastened Windows

Windows Installed into Walls with Polyiso and Wood Framing. Installation Instructions Picture Frame Method Revised 10/24/2016

Picture Window Rough Opening Installation with Sheathing Intact with Brickmould Tools: (Not supplied by manufacturer) Fig. 0-1

STACKING MULTI-SLIDE DOOR SYSTEM INSTALLATION INSTRUCTIONS

WEB BASED CORE APPLICATION SPECIFIC INSTALLATION INFORMATION AND METHODS

Integrity Polygon and Round Top Installation and Finishing Instructions

Sun Windows General Information New Construction Sliding Door Installation Instructions H F

Sun Windows General Information New Construction Hinged Door Installation Instructions

3.4 Wall Flashing Wall Flashing General

Windows Installed into Walls with Polyiso and Wood Framing. Installation Instructions Standard Method Revised 10/24/2016

DuPont Self-Adhered Flashing Systems Products

THERMO-FIT REPLACEMENT WINDOW INSTALLATION INSTRUCTIONS (BRICKMOULD / NO NAILING FLANGE)

window installation Guide wood FRaMinG New Construction

INSTALLATION INSTRUCTIONS for Vinyl Windows with Integral Nailing Fin (JII001) IMPORTANT INFORMATION & GLOSSARY ROUGH OPENINGS

DuPont Flashing Systems Commercial Installation Guidelines

NEW CONSTRUCTION, REPLACEMENT AND FLUSH FIN REPLACEMENT WINDOW INSTALLATION INSTRUCTIONS

CFDTT-01. Control Joint Study (General)

INSTALLATION INSTRUCTIONS for Wood Bay or Bow Windows with Nailing Fin or Exterior Trim (JII032)

DuPont Flashing Systems Installation Guidelines

Tamko. tw window & door flash Flashing Membrane PRODUCT DATA *

Keeping Water Out of. Stucco Walls. by Gene Summy. Assume that the cladding will leak, but make sure the envelope is watertight

Installation Instructions Double-Hung, Single-Hung, Casement, Awning, Sliding, Picture & Shapes Non-Impact & Impact Resistant Nailing Fin Windows

NEW CONSTRUCTION PATIO DOOR INSTALLATION INSTRUCTIONS (WITH NAILING FLANGE)

SERIES 4070-T GENERAL ASSEMBLY AND INSTALLATION INSTRUCTIONS

TAMKO. TW MOISTURE WRAP Above Grade Moisture / Air Barrier Membrane PRODUCT DATA

Installation Instructions for E-Series 2 or 4-Panel Gliding and French Gliding Patio Doors

INSTALLATION INSTRUCTIONS IMPERVIA (Vent and Fixed) AWNING, CASEMENT, and LARGE AWNING WINDOW WITH FINS

Norwood Windows Permaglass Fiberglass Products Installation Instruction

Window with Nail fin (New construction)

Installation Instructions

UNIT 5: EXTERIOR DOORS AND WINDOWS

DuPont Flashing Systems Installation Guidelines. Version 2

Adorn Mortarless Stone Veneer Installation Natural Concrete Products

Installation Guidelines for all Quaker products with nail fins New Construction nail fin installation with a Zip sheathing system.

A REFERENCE GUIDE OF TYPICAL RAINSCREEN WALL AND WINDOW DETAILS

INSTALLATION INSTRUCTIONS for Wood/Clad Wood Windows without Exterior Trim or Nailing Fin (JII025) ImpOrTaNT INFOrmaTION & GlOssary.

INSTALLATION INSTRUCTIONS for Wood/Clad Wood Windows with Exterior Trim or Nail Fin (JII024)

Blue Barrier Flash N Wrap 2400

INSTALLATION INSTRUCTIONS IMPERVIA SLIDING PATIO DOOR WITH FINS

Installation Recommendations for Finless Frame Doors

How To Install Windows: Nail-Fin Application

POCKETING MULTI-SLIDE DOOR SYSTEM

Window Frame Installation Instructions For Nail-on and Block Frames

Pocket Door Installation Instructions

HydroGap Drainable Housewrap: Installation Instructions

INSTALLATION INSTRUCTION SINGLE PANEL, SINGLE PANEL WITH SIDELIGHT COMBINATION AND 20 MINUTE FIRE RATED WOOD FRAME ENTRY DOOR

Before installation, check your local and state requirements for this type of install.

Curtain Wall Installation Guide

I n s t a l l a t i o n I n s t r u c t i o n s

IMPORTANT: Please read completely before you begin.

Flashing Materials. Rough Opening Preparation

Installer Please leave this booklet for the homeowner after the install is completed. IMPORTANT: Please read before you begin.

DuPont Flashing Systems Installation Guidelines. Version 2

Metal & Vinyl, Flush Mount and Recessed Fin Windows Recommended Installation Instructions

Installation Guide for E-Series/Eagle Ascent 2 or 4 Panel Gliding (Sliding) Patio Doors

FOLDING DOOR - FOR FACTORY ASSEMBLED JAMBS WITH APPLIED SILL

DuPont Flashing Systems Installation Guidelines

STACKING MULTI-SLIDE DOOR SYSTEM

Building Wrap and Flashing

INSTALLATION INSTRUCTIONS for Wood Bay or Bow Windows with Nailing Fin or Exterior Trim (JII032) IMPORTANT INFORMATION AND GLOSSARY ROUGH OPENINGS

TARGA 7100 SINGLE HUNG INSTALLATION INSTRUCTIONS NOTE: Read instructions completely before attempting any installation.

TARGA 7300 CASEMENT INSTALLATION INSTRUCTIONS NOTE: Read instructions completely before attempting any installation.

Building Wrap and Flashing

GENERAL INSTALLATION GUIDELINES

GENERAL INSTALLATION GUIDELINES

DuPont Flashing Systems Installation Guidelines

(773) INSTALLATION INSTRUCTIONS for Vinyl Windows with Integral Nailing Fin (JII001) IMPORTANT INFORMATION & GL OSSARY ROUGH OPENINGS

Steel Reinforced Joining Thank you for choosing Andersen. Please leave this guide with building owner.

INSTALLATION INSTRUCTIONS for Vinyl Windows with Integral Nailing Fin (JII001)

DuPont Flashing Systems Installation Guidelines. Version 2

Transcription:

Products: 12" RainBuster #415 Self-Adhered Flashing Membrane-40mil 12" RainBuster #415 Self-Adhered Flashing Membrane-25mil 12" RainBuster #420 Nail On Flashing Membrane-25mil RainBuster #430-4.0 Recess Quick Corner (2) Recess Depth: 4"= #430-4.0, Greater than 4"= #430-4.0 (Modified) See section details in Step 3. RainBuster #450 Ultra High Performance Window & Door Sealant Step 1. Install Sill Flashing at Recessed Opening Product: 12" RainBuster #420 Nail On Flashing Membrane-25mil 1.A Flashing Length = (Recessed Opening Width) + 12" 1.B Install sill flashing flush with the sill of the recessed opening. Each end of the sill flashing should extend 6" beyond the jambs of the recessed opening. 1.C Fasten with staples or nails along top edge of sill flashing tight to the recessed opening (within 1" of the edge of the recessed opening). 1.D Do not fasten along bottom edge of sill flashing. This will allow for the weather resistive barrier to be installed behind the sill flashing in a weather board fashion. Step 2. Sealant Application Prior to Installation of Recess Quick Corners Product: RainBuster #450 Ultra High Performance Window & Door Sealant 2.A Apply a 3/8" continuous bead of sealant at the recessed sill/buck joint and recessed jamb/buck joint. Sealant should be applied 2 ½" across the recessed sill and up the recess jamb 2 ½". 2.B Apply a 3/8" continuous bead of sealant at the recessed sill/recessed jamb joint. The sealant applied at the recessed sill/recessed jamb joint should extend from the face of the bucks onto the exterior face of the sill flashing at the outside wall a minimum of 1". Note: When the #430-4.0 is modified to accommodate recess depths greater than 4" the sealant should be applied at the front and back of the recess opening. The sealant should be located to allow the outside and inside corner portions to be bedded in sealant. pg 1 of 8

Step 3. Install Recess Quick Corners at Recessed Sill Corners Product: RainBuster #430-4.0 Recess Quick Corners 3.A Recess Depth: 4"= #430-4.0, Greater than 4"= #430-4.0 (Modified) See section details below. 3.B Apply a continuous 3/8" bead of sealant (L-shaped) to the backside of the outside wall leg of the Recess Quick Corner insuring a continuous seal between the Recess Quick Corner and the flashing/framing. 3.C Position Recess Quick Corners firmly into buck/recessed sill/recessed jamb/ outside wall corners. 3.D Install Recess Quick Corner using nails or staples insuring secure attachment through vertical legs only. Note: For recess depths greater than 4" modify the #430-4.0 by cutting along the middepth cut line separating the outside corner portion from the inside corner portion. The outside corner portion and the inside corner portion will be installed separately. Double 2 x 4 walls with 7 /16"- 1 /2" sheathing, 1 1 /2" reveal with 3" reveal option 6" sheathed recess ( 7 /16"- 1 /2"sheathing), 1 1 /2" reveal with 3" reveal option Vertical Section Elevation Vertical Section Elevation Step 4. Install Flashing at Recessed Sill Corners Product: 12" RainBuster #415 Self-Adhered Flashing Membrane-40mil 4.A Flashing Length = (Recessed Opening Depth) + 4" 4.B Adhere flashing across recessed sill, over Recess Quick Corners, and up recessed jamb maintaining 3" of adhesion to recessed sill and jamb. Press flashing firmly into inside corner eliminating any voids or wrinkles between the flashing and Recess Quick Corners. 4.C Make relief cut at corner allowing flashing to fold and adhere over sill and jamb. 4.D Using a J-Roller, apply pressure while rolling entire surface of flashing to insure adequate adhesion. pg 2 of 8

Step 5. Install Flashing on Recessed Sill at Outside Wall Product: 12" RainBuster #415 Self-Adhered Flashing Membrane-40mil 5.A Flashing Length = (Recessed Opening Width) 5.B Adhere flashing across recessed sill and over recessed sill flashing (minimum 4" lap). 5.C Using a J-Roller, apply pressure while rolling entire surface of flashing to insure adequate adhesion Step 6. Install Flashing on Recessed Sill Product: 12" RainBuster #415 Self-Adhered Flashing Membrane-40mil 6.A Flashing Length = (Recessed Opening Width) 6.B Adhere flashing flush to the sill of the window rough opening, down wood blocking, across recessed sill, and over existing flashing (minimum 3" lap). Press flashing firmly into wood blocking/recessed sill corner eliminating any voids or wrinkles. 6.C Using a J-Roller, apply pressure while rolling entire surface of flashing to insure adequate adhesion. pg 3 of 8

Step 7. Install Jamb Flashing Product: 12" RainBuster #420 Nail On Flashing Membrane-25mil 7.A Flashing Length = (Recessed Opening Height) + 2" 7.B Position jamb flashing into recessed opening. Fold flashing onto bottom of header at wood blocking/recessed header/jamb corner. 7.C Install jamb flashing flush with the jamb of the window rough opening. Jamb flashing should extend 2" onto recessed header and to the bottom of the recessed opening. Press jamb flashing firmly into wood blocking/recessed jamb corner eliminating any voids or wrinkles. 7.D Fasten with staples or nails along edge of flashing tight to the rough opening (within 1" of edge of the rough opening), in upper corner to secure folded flashing to bottom of recessed header, and along front edge of flashing. pg 4 of 8

Step 8. Install Jamb Flashing at Outside Wall Product: 12" RainBuster #415 Self-Adhered Flashing Membrane-25mil 8.A Flashing Length = (Recessed Opening Height) + 14" 8.B Position jamb flashing into recessed opening. Make 2" vertical relief cut at top of jamb flashing to allow flashing to fold onto bottom of header at recessed header/jamb corner. 8.C Adhere jamb flashing over existing jamb flashing (minimum 3" lap), onto recessed header, across recessed jamb, and onto outside wall (minimum 4"). Jamb flashing should extend 2" onto the recessed header and to within 1/2" or flush with the bottom edge of the sill flashing. 8.D Make L shaped relief cut at bottom of jamb flashing to allow jamb flashing to lap over recessed sill flashing. 8.E Using a J-Roller, apply pressure while rolling entire surface of jamb flashing to insure adequate adhesion. 8.F Do not fasten along bottom edge of jamb flashing. This will allow for the weather resistive barrier to be installed behind the sill flashing in a weather board fashion. Step 9. Install Integral Flanged Window Product: RainBuster #450 Ultra High Performance Window & Door Sealant 9.A Apply a 3/8" continuous bead of sealant to the backside of the entire window flange. Apply sealant in line with the prepunched holes in the window flange. 9.B Sealant must be applied no longer than 20 minutes prior to installation of window. 9.C Install window per window manufacturer s installation specifications insuring window is securely fastened and plumb, level, and square. 9.D Sealant squeeze out should be visible around entire perimeter and through all prepunched holes in the window flange. pg 5 of 8

Step 10. Apply Cap Bead of Sealant Product: RainBuster #450 Ultra High Performance Window & Door Sealant 10.A Apply a 1/2"-5/8" cap bead of sealant to the edge of the entire window flange. Using a putty knife, flatten or butter cap bead and sealant squeeze out. Buttered sealant should extend 2" away from the window frame (approximately 1" beyond the outer edge of the window flange). 10.B Insure that all nail/screw heads are covered with sealant. Step 11. Install Head Flashing Product: 12" RainBuster #420 Nail On Flashing Membrane-25mil 11.A Flashing Length = (Rough Opening Width) 11.B Install head flashing over the window flange and flush with the top of the window at the top of recessed opening. The head flashing should extend across the width of the recessed opening. 11.C Embed head flashing into sealant at the head of the window. Press the head flashing into the sealant until sealant appears at the bottom edge of the flashing. Press head flashing firmly into wood blocking/recessed header corner, eliminating any voids or wrinkles. 11.D Fasten with staples or nails along top edge and at each end of head flashing at recessed header/jamb corners (within 1" of each end of head flashing). Use minimum number of fasteners required to keep flashing in place pg 6 of 8

Products: 12" RainBuster #415 Self-Adhered Flashing Membrane-40mil 12" RainBuster #415 Self-Adhered Flashing Membrane-25mil 12" RainBuster #420 Nail On Flashing Membrane-25mil RainBuster #430-4.0 Recess Quick Corner (2) Recess Depth: 4"= #430-4.0, Greater than 4"= #430-4.0 (Modified) See section details in Step 3. RainBuster #450 Ultra High Performance Window & Door Sealant Step 12. Install Head Flashing at Outside Wall Product: 12" RainBuster #415 Self-Adhered Flashing Membrane-25mil 12.A Flashing Length = (Rough Opening Width) + (Width of Jamb Flashings) + 2" 12.B Install head flashing at the top of recessed opening. Each end of the head flashing should extend the width of the jamb flashing + 1" on each side of the recessed opening. 12.C Position head flashing into recessed opening and temporarily secure along top edge. 12.D Make vertical relief cuts at recessed jambs to allow head flashing to fold into recessed opening. 12.E Adhere head flashing over existing head flashing (minimum 3" lap), across recessed header, and up the outside wall a minimum of 4". 12.F Using a J-Roller, apply pressure while rolling entire surface of head flashing to insure adequate adhesion. 12.G Fasten with staples or nails along top edge of head flashing. Use minimum number of fasteners required to keep flashing in place. Step 13. Apply Cap Bead of Sealant at Recessed Corners Product: RainBuster #450 Ultra High Performance Window & Door Sealant 13.A Apply a 1/2"-5/8" cap bead of sealant at the recessed sill/jamb corners. Using a putty knife, tool sealant into corners insuring flashing seams are sealed. pg 7 of 8

Products: 12" RainBuster #415 Self-Adhered Flashing Membrane-40mil 12" RainBuster #415 Self-Adhered Flashing Membrane-25mil 12" RainBuster #420 Nail On Flashing Membrane-25mil RainBuster #430-4.0 Recess Quick Corner (2) Recess Depth: 4"= #430-4.0, Greater than 4"= #430-4.0 (Modified) See section details in Step 3. RainBuster #450 Ultra High Performance Window & Door Sealant Step 14. Installation of Bond Breaker (by others) Product: Weather resistive barrier (building paper) by others (non-rainbuster product) 14.A After the weather resistive barrier has been properly integrated (weather board/ship lap fashion) with the window and door flashing systems, an additional piece of weather resistive barrier should be installed over the sill flashing acting as a bond breaker. 14.B Position weather resistive barrier onto reveal, recessed sill, and outside wall. Remove and cut to size. DO NOT CUT IN PLACE. Reposition and temporarily secure with minimum number of furring nails required to keep weather resistive barrier in place. Seal furring nails with RainBuster 900 Sealant/ Adhesive. Weather resistive barrier should be flush with bottom of window and flush with the recessed sill/jamb corners, continuing down the outside wall, covering the flashing completely. Installation Recommendations: It s recommended that backing (OSB, plywood, dimensional lumber) be installed to support flashing at all window and door openings. Installation substrates should be clean and free from substances and protrusions that could adversely effect adhesion and or compromise flashing/membrane performance. When an installation requires adhering RainBuster #415 Self-Adhered Flashing Membrane directly to the substrate (OSB, plywood, fiberglass faced gypsum board, masonry, and concrete) an adhesion test is recommended to insure sufficient adhesion is achieved. Adhesion may be improved by rolling the membrane with a J-roller. In some cases priming the surface with an approved primer may be required to achieve sufficient adhesion. In 3-coat stucco applications, it s recommended that all flashing be covered by the Weather Resistive Barrier (WRB). After the WRB has been properly integrated (weather board/ship lap fashion) with the window and door flashing systems an additional piece of WRB should be installed over the sill flashing acting as a bond breaker. pg 8 of 8