9190A Ultra-Cool Field Metrology Well. Ultra-cool dry-block calibrator with best-in-class stability

Similar documents
Ultra-cool dry-block calibrator with best-in-class stability Technical Data. Improved process control

9190A Ultra-Cool Field Metrology Well

Additel 875 Series Dry Well Calibrators

Additel 875 Series Dry Well Calibrators

1586A Super-DAQ Precision Temperature Scanner. The most accurate and flexible temperature data acquisition system on the market. Fluke-Direct.

Fluke 712B and 714B Temperature Calibrators

High-precision process calibrator Model CED7000

5520A. Multi-Product Calibrator. Extended Specifications

5502A Multi-Product Calibrator. Extended specifications

CALYS 150. Advanced documenting multifunction calibrator thermometer

5522A Multi-Product Calibrator Extended specifications

CALYS 150. Advanced documenting multifunction calibrator thermometer

CALYS Transportable documenting multifunction calibrator with high accuracy 0.01%

5500A. Multi-Product Calibrator. Extended Specifications 2005

CALYS 150. Advanced documenting multifunction calibrator thermometer

5790A Automated AC Measurement Standard

5520A. Multi-Product Calibrator. Extended Specifications 2005

Fluke 5820A Oscilloscope Calibrator Specifications

CALYS 100. Field precision documenting multifunction calibrator

1594A/1595A Super-Thermometers. Recognized worldwide for ease of use and reliable accuracy

Hand-held temperature calibrator Model CEP3000

CALYS 75. Field documenting multifunction calibrator

Fluke 3540 FC Three-Phase Power Monitor

ONE CALIBRATOR ONLY MAIN FEATURES:

525B Temperature/ Pressure Calibrator Superior accuracy and functionality in an economical benchtop package

CALYS 50. Field multifunction calibrator for basic use

Model 1140A Thermocouple Simulator-Calibrator

5080A Multi-Product Calibrator

Fluke 370 FC Series True-rms Wireless AC/DC Clamp Meters

Fluke 8845A/8846A Digital Multimeters Extended Specifications

6135A/PMUCAL Phasor Measurement Unit Calibration System

1587/1577 Insulation Multimeters

QA-ES III Electrosurgical Analyzer

QA-ES III Electrosurgical Analyzer

Fluke 83V and 87V Digital Multimeters

Standard Resistors Precision DC Shunts Digital Thermometers Non-inductive AC Shunts Intelligent Teraohmmeter Precision Decade Standards Precision Air

Temperature Transmitters - Head Mounted

Compact Signal Calibrator

1650 Series Multifunction Installation Testers

Measure voltage without test leads. Product Highlights

PROGRAMMABLE FIELD TEMPERATURE TRANSMITTER

SureGrip TM. XWWarning

MODEL: M6SXU MODEL: M6SXU [1][2] [3][4]

Compact Signal Calibrator

TR CRITERIA FOR LABORATORY ACCREDITATION IN THE FIELD OF ELECTRICAL DCLF METROLOGY. Approved By: Senior Manager: Mpho Phaloane Revised By:

5320A. Multifunction Electrical Tester Calibrator. Extended Specifications

374/375/376 Clamp Meter

MODEL: M2XU MODEL: M2XU [1][2] [3][4]

M1 Series. Humidity - Temperature Transmitter INSTRUCTION MANUAL

5320A Multifunction Electrical Tester Calibrator. Verify and calibrate electrical test tools with a single instrument

Fluke 1587 FC/1577 Insulation Multimeters

MEMOCAL 2000/2000S. Hand-held calibrator

374/375/376 Clamp Meter

Fluke and

Temperature transmitter itemp PCP DIN rail TMT 121

DTI-1000 & STS-100/102. Digital Temperature Indicator & STS Reference Sensor

An Evaluation of Artifact Calibration in the 5700A Multifunction Calibrator

TEK-TEMP 2100A. Explosion-Proof Temperature Transmitter. TEMPERATURE. Technology Solutions

Measuring uncommon RTDs with the Fluke 726

Compact Signal Calibrator

Analogue Temperature Transmitter

Temperature Transmitters - DIN Rail Mounted

Installation Tester and DMM Kits

Roline L1 Series. Humidity - Temperature Transmitters INSTRUCTION MANUAL

374 FC/375 FC/376 FC Clamp Meter

Temperature Sensing and Measurement Solutions THERMOMETRY PRODUCT GUIDE

So advanced, we had to create a new category

Fluke 170 Series True-rms Digital Multimeters

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.

RTD Temperature Sensor omnigrad T -TSM 480, TR 480. Hygienic RTD sensor with Pt 100, class A TSM 480 with electronics programmable via PC

1507/1503. Insulation Testers. Technical Data. Features and benefits:

SINEAX V 624 Programmable Temperature Transmitter for RTD and TC inputs

FST Series HUMIDITY-TEMPERATURE TRANSMITTERS INSTRUCTION MANUAL

Oscilloscope Calibration Options for 55XX Series Multi-Product Calibrators

Fluke 2638A/05 Hydra Series III 22-Channel Data Acquisition System

Oscilloscope Calibration Options for Fluke 5500A/5520A Multi-Product Calibrators Extended Specifications

SMART TEMPERATURE TRANSMITTERS. smar

Technical data ESA614 Electrical Safety Analyzer

Fluke 1740 Series. Three-Phase Power Quality Loggers Memobox. Assess power quality and conduct long-term studies with ease

MICROCAL Palm-top Multifunction Calibrators. Bulletin n (E)

712B/714B. Calibration Manual. RTD/Thermocouple Calibrator

USB-2404-UI Specifications

Troubleshooting. process loops. All. Application Note. Loop calibrators. ProcessMeter

Workshop equipment. Solutions Beamex solutions for paperless calibration as well as configuration and calibration of smart instruments.

ScopeMeter Test Tool CSV files available for FlukeView software and Microsoft Excel Application Note

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Analogue temperature controllers

The Rosemount 848T Wireless Temperature Transmitter

itemp HART DIN rail TMT112

The Fluke 6100A. Electrical Power Standard. The most accurate, comprehensive and flexible source of electrical power signals

600T Series Transmitters. Specification Sheet. Model 653T Electronic temperature transmitter (PC programmable)

Millikelvin Thermometers MKT 10 MKT 50

712C. Users Manual. RTD Calibrator

Integrated calibration system for electronic and pneumatic instrumentation model CBS-SC2000

MODEL: M3LU2. OUTPUT Field-selectable Current 0 20 ma DC Voltage V DC V DC

1523, 1524 Thermometer Readout User s Guide

Fluke 570 Series Infrared Thermometers:

PID500 FULL FEATURED PID TEMPERATURE CONTROLLERS

323/324/325 Clamp Meter

Transcription:

9190A Ultra-Cool Field Metrology Well Ultra-cool dry-block calibrator with best-in-class stability

9190A Ultra-Cool Field Metrology Well The most accurate and stable instrument in its class The Fluke Calibration 9190A Ultra-Cool Field Metrology Well is the most accurate and stable, cold temperature dry-block on the market. It s ideal for applications that demand strict quality control and regulatory process compliance. These applications include on-location validation and calibration of RTDs, thermocouples, thermometers, and sensors used with process control equipment such as medical freezers, laboratory refrigerators, cold rooms, blood banks, sterilizers (autoclaves), and freeze dryers. Great for cleanroom environments Calibration baths are the most stable and uniform temperature sources available, but they aren t a good fit for cleanrooms. The size of a bath limits its portability, and bath fluids can easily spill and give off vapors. The 9190A Ultra-Cool Field Metrology Well is a great alternative. Its wide temperature range brackets the coldest and highest temperature ranges required for pharmaceutical, biomedical and food processing applications. The 9190A is small and lightweight, making it easy to transport. And since it does not use heat transfer fluids, cleanrooms stay clean. The 9190A cooling and heating times are faster than a calibration bath that means calibration work gets done more quickly.

Wide temperature range From 95 C to 140 C An accurate temperature source is critical for dependable process measurements Unreliable process measurements can have a damaging impact on business, leading to poor product quality, recalls, fines, waste, and lost profits. Ultimately, measurements are only as good as the temperature sources used to calibrate the measurement equipment. The 9190A Ultra-Cool Field Metrology Well incorporates the best technology and design expertise gained from decades of dry-block development experience. The 9190A conforms to EURAMET cg-13, guidelines for best measurement practices for temperature block calibrators. As a result, you can be assured that the 9190A specifications for accuracy, stability, axial (vertical) uniformity, radial (well-to-well) uniformity, loading, and hysteresis have been thoroughly and carefully defined and tested. With a 9190A Ultra-Cool Field Metrology Well, you can be confident you re using the most accurate and stable ultra-cool dry-block calibrator available. And that will have a positive impact on your business. Excellent accuracy Accuracy using built-in reference thermometer readout: ± 0.05 C full range Display accuracy: ± 0.2 C full range Best-in-class stability ± 0.015 C full range Fast cooling time 23 C to 90 C: 80 minutes 23 C to 95 C: 90 minutes 140 C to 23 C: 60 minutes Portability Weighs only 16 kg (35 lbs) Built-in front and back handles for easy two-handed carry Best measurement practices Conforms to EURAMET cg-13 guidance on measurement practices for temperature block calibrators Calibration equipment accuracy and stability Lower calibration uncertainty Improved process control Increased measurement reliability Business results Accurate and stable calibration equipment impacts business results (e.g. quality, efficiency, less waste) 9190A Ultra-Cool Field Metrology Well 3

9190A features at a glance Dual heater zone Active heater zone control compensates for differential temperatures between zones Minimizes axial temperature gradients Ergonomics Two-handed carry; built-in handles on front and back All controls and inputs on the front panel Ramp-and-soak set-points Define up to eight set-point temperatures; automatically ramp to and soak at each set-point Specify soak time, number of cycles, and direction Fast time to temperature and small footprint Uses compact, efficient free piston stirling cooler technology (FPSC) Remote operation USB and RS-232 communications interfaces support remote operation from a computer Stability indicator Indicates when the block temperature is stable and within limits defined by the user 4 9190A Ultra-Cool Field Metrology Well

9190A optional process features Reference sensor control Set-point temperature control gets passed from the internal sensor to external reference PRT 9190A controls the well temperature based on its measurement and position inside the well Helps minimize the effects of the axial gradient when reference PRT is aligned with short sensors 4-20 ma connectors Power a 4-20 ma transmitter from the drywell Supplies 24 V dc loop power 4-wire PRT/RTD input Reads a 4-wire, 3-wire, or 2-wire PRT/RTD Accuracy ±0.02 ºC Reference thermometer input Reference thermometer input automatically reads Fluke Calibration PRTs terminated with a smart connector Accuracy ±0.01 C at 95 C (readout accuracy only) 4-20 ma circuit fuses Thermocouple input Accepts common thermocouples with mini-jack termination Types: J, K, T, E, R, S, M, L, U, N, C 9190A Ultra-Cool Field Metrology Well 5

Specifications Base unit specifications Temperature range at 23 C 95 C to 140 C ( 139 F to 284 F) Display accuracy ± 0.2 C full range Accuracy with external reference [3] ± 0.05 C full range Stability ± 0.015 C full range Axial uniformity at 40 mm (1.6 in) ± 0.05 C full range Radial gradient ±0.01 C full range Loading effect (with a 6.35 mm reference probe and three 6.35 mm probes) ± 0.006 C full range (versus display with one 6.35 mm probe) ± 0.25 C at 95 C ± 0.10 C at 140 C Operating conditions 0 C to 35 C, 0 % to 90 % RH (non-condensing) < 2000 m altitude Environmental conditions for all 13 C to 33 C specifications except temperature range Immersion (well) depth 160 mm (6.3 in) Well diameter 30 mm (1.18 in) Heating time [1] 95 C to 140 C: 40 min Cooling time [1] 23 C to 90 C: 80 min 23 C to 95 C: 90 min 140 C to 23 C: 60 min Stabilization time [2] 15 min Resolution 0.01 Display LCD, C or F user selectable Size (H x W x D) 480 mm x 205 mm x 380 mm (18.8 in x 8.0 in x 14.9 in) Weight 16 kg (35 lb) Power requirements 100 V to 115 V (± 10 %) 50/60 Hz, 575 W 200 V to 230 V (± 10 %) 50/60 Hz, 575 W System fuse ratings 115 V: 6.3 A T 250 V 230 V: 3.15 A T 250 V 4 20 ma Fuse (-P model only) 50 ma F 250 V Computer interface RS-232, USB Serial, and 9930 interface-it temperature calibration software included Safety IEC 61010-1, Installation Category II, Pollution degree 2 Electromagnetic environment IEC 61326-1: Basic Refrigerants R32 (Difluoromethane) < 20 g, ASHRAE safety group A2L R704 (Helium) < 20 g, ASHRAE safety group A1 6 9190A Ultra-Cool Field Metrology Well

-P Specifications Built-in reference thermometer readout ± 0.010 C at 95 C accuracy (4-wire reference probe) [3] ± 0.013 C at 25 C ± 0.015 C at 0 C ± 0.020 C at 50 C ± 0.025 C at 140 C Reference resistance range 0 Ω to 400 Ω Reference resistance accuracy [4] 0 Ω to 42 Ω: ± 0.0025 Ω 42 Ω to 400 Ω: ± 60 ppm of reading Reference characterizations ITS-90, CVD, IEC-751, resistance Reference measurement capability 4 wire Reference probe connection 6-pin din with INFO-CON technology Built-in RTD thermometer readout accuracy NI-120: ± 0.015 C at 0 C PT-100 (385): ± 0.02 C at 0 C PT-100 (3926): ± 0.02 C at 0 C PT-100 (JIS): ± 0.02 C at 0 C RTD resistance range 0 Ω to 400 Ω Resistance accuracy [4] 0 Ω to 25 Ω: ± 0.002 Ω 25 Ω to 400 Ω: ± 80 ppm of reading RTD characterizations PT-100 (385),(JIS),(3926), NI-120, resistance RTD measurement capability 2-wire, 3-wire, and 4-wire RTD with jumpers only RTD connection 4-terminal input Built-in TC thermometer readout accuracy [5] Type J: ± 0.70 C at 140 C Type K: ± 0.75 C at 140 C Type T: ± 0.60 C at 140 C Type E: ± 0.60 C at 140 C Type R: ± 1.60 C at 140 C Type S: ± 1.60 C at 140 C Type M: ± 0.65 C at 140 C Type L: ± 0.65 C at 140 C Type U: ± 0.70 C at 140 C Type N: ± 0.75 C at 140 C Type C: ± 1.00 C at 140 C TC millivolt range 10 mv to 75 mv Voltage accuracy 0.025 % of reading +0.01 mv Internal cold junction compensation accuracy ± 0.35 C (ambient of 13 C to 33 C) TC connection Miniature connectors (ASTM E1684) Built-in ma readout accuracy 0.02 % of reading + 0.002 ma ma range Cal 4-22 ma, Spec 4-24 ma ma connection 2 terminal input Loop power function 24 V dc loop power Built-in electronics temperature coefficient ± 0.005 % of range per C (0 C to 13 C, 33 C to 50 C) Notes: [1] For ambient temperature of 23 C. [2] Time from when the SETPOINT is reached to when the unit is with in stability specification. [3] The temperature range may be limited by the reference probe connected to the readout. The built-in reference accuracy does not include the sensor probe accuracy. It does not include the probe uncertainty or probe characterization errors. [4] Measurement accuracy specifications apply within the operating range and assume 4 wires for PRTs. With 3-wire RTDs add 0.05 Ω to the measurement accuracy plus the maximum possible difference between the resistances of the lead wires. [5] The thermocouple input readout is sensitive to EM fields in the frequency range of 500 MHz to 700 MHz. 9190A Ultra-Cool Field Metrology Well 7

Ordering Information 9190A Ultra-Cool Field Metrology Well Model Description 9190A-X Ultra-Cool Field Metrology Well, 95 C to 140 C, with 9190-INSX 9190A-X-P Ultra-Cool Field Metrology Well, 95 C to 140 C, with 9190-INSX, with Process Electronics X in the above model numbers to be replaced with A, B, C, D, E, and F as appropriate for the desired insert. See the inserts illustration and listing below. Recommended accessories Model Description 9190-INSA Insert A 9190, imperial miscellaneous holes 9190-INSB Insert B 9190, imperial comparison holes 9190-INSC Insert C 9190, 0.25 inch holes 9190-INSD Insert D 9190, metric comparison holes 9190-INSE Insert E 9190, metric miscellaneous holes with 0.25 inch hole 9190-INSF Insert F 9190, metric comparison miscellaneous holes with 0.25 inch hole 9190-INSY Insert Y 9190, custom insert Custom insert is based on a maximum of eight holes. Please contact your local sales representative if you have special requirements. 9190-INSZ Insert Z 9190, blank Fluke Calibration. Precision, performance, confidence. Fluke Calibration PO Box 9090, Everett, WA 98206 U.S.A. Fluke Europe B.V. PO Box 1186, 5602 BD Eindhoven, The Netherlands For more information call: In the U.S.A. (877) 355-3225 or Fax (425) 446-5116 In Europe/M-East/Africa +31 (0) 40 2675 200 or Fax +31 (0) 40 2675 222 In Canada (800)-36-FLUKE or Fax (905) 890-6866 From other countries +1 (425) 446-5500 or Fax +1 (425) 446-5116 Web access: http://www.flukecal.com 2013 Fluke Calibration. Specifications subject to change without notice. Printed in U.S.A. 1/2013 4264843A_EN Pub ID 12015-eng. Modification of this document is not permitted without written permission from Fluke Corporation.