JOURNAL OF ADVANCEMENT IN ENGINEERING AND TECHNOLOGY

Similar documents
HUMAN BODY MONITORING SYSTEM USING WSN WITH GSM AND GPS

ECONOMICAL HEART RATE MEASUREMENT DEVICE WITH REMOTE MONITORING USING FINGERTIP

GSM BASED PATIENT MONITORING SYSTEM

International Journal of Electronics and Communication Engineering & Technology (IJECET), ISSN COMMUNICATION ENGINEERING & TECHNOLOGY (IJECET)

GSM based Patient monitoring system

An Intelligent Wearable e-belt for Continuous Monitoring of Sinus Rhythm

Multi Propose Biomedical Circuit

Robust Wrist-Type Multiple Photo-Interrupter Pulse Sensor

A COLOUR - CODED BRACELET MODELLING SYSTEM

International Journal of Scientific & Engineering Research, Volume 5, Issue 5, May ISSN

IoT based Heart Attack Detection, Heart Rate and Temperature Monitor

Soldier Tracking and Health Indication System Using ARM7 LPC-2148

An IoT based Remote HRV Monitoring System for Hypertensive Patients

Voice Activated Hospital Bed, Herat Beat, Temperature Monitoring and Alerting System

Design and Development of PIC Microcontroller based Wireless Architecture for Human Health Monitoring

DESIGN OF A PHOTOPLETHYSMOGRAPHY BASED PULSE RATE DETECTOR

For Immediate Release. For More PR Information, Contact: Carlo Chatman, Power PR P (310) F (310)

ULP Wireless Technology for Biosensors and Energy Harvesting

Get your daily health check in the car

Design and Implementation of Digital Stethoscope using TFT Module and Matlab Visualisation Tool

Monitoring System Heartbeat and Body Temperature Using Raspberry Pi

Designing and Manufacturing a Device of Transmission and Recording Vital Signs through Mobile Phone Network

REAL-TIME WIRELESS ECG AND ITS SIGNAL DISPLAY ON LABVIEW

Hardware Implementation of an Explorer Bot Using XBEE & GSM Technology

LABORATORY AND FIELD INVESTIGATIONS ON XBEE MODULE AND ITS EFFECTIVENESS FOR TRANSMISSION OF SLOPE MONITORING DATA IN MINES

Keyword: AVR Microcontroller, GSM, LCD, remote monitoring, Sensors, ZigBee.

Wireless Cardiac Rhythm Monitoring System

Management of Home Appliances with Variation in Environment Aisha Jilani, Sahar Sultan, Intesar Ahmed and Sajjad Rabbani

GPS and GSM Based Transmission Line Monitoring System with Fault Detection Introduction:

Lab: Using filters to build an electrocardiograph (ECG or EKG)

Preliminary Design Report with Diagram(s)

An IoT Based Real-Time Environmental Monitoring System Using Arduino and Cloud Service

Embedded based Wireless Healthcare Monitoring Vivek S. Metange 1 Prof. J. J. Chopade 2

Wireless Data Acquisition and Transmission System Design Using Arduino (for Military Jawan alive Detection Network)

AN EMBEDDED 1/3 PHASE AUTOMATIC TRANSFER SWITCH WITH INTELLIGENT ENERGY MANAGEMENT

Advanced Soldier Monitoring and Tracking System Using GPS and GSM Introduction

Wireless Heartbeat Monitoring System Using Android

II. BLOCK

A Body Area Network through Wireless Technology

A Design Of Simple And Low Cost Heart Rate Monitor

Intelligent Traffic Light Controller

Design and Development of Pre-paid electricity billing using Raspberry Pi2

Design of WSN for Environmental Monitoring Using IoT Application

Arduino and Raspberry Pi based Efficient Patient Monitoring System

Abstract. Index Terms Healthcare model, Paralysis, Surface electromyography, wireless engineering.

International Journal of Advancements in Research & Technology, Volume 2, Issue 12, December ISSN

Wireless Sensor Network for Intra-Venous Fluid Level Indicator Application

WIRELESS ELECTRONIC STETHOSCOPE USING ZIGBEE

medlab Two Channel Invasive Blood Pressure OEM board EG 02000

Design and Development of a Two Channel Telemedicine System for Rural Healthcare

Design And Implementation Of A Wireless Microcontroller Based Heart Pulse Meter With Liquid Crystal Display

Testing Properties of E-health System Based on Arduino

GSM Based Patient Monitoring System using biomedical sensors

A REAL TIME MONITORING SYSTEM FOR PHYSIOLOGICAL SIGNALS USING WIRELESS SENSOR NETWORK. P.Amaranadha reddy 1, J.Damodhar 2

AUTOMATIC ELECTRICITY METER READING AND REPORTING SYSTEM

PHYSIOLOGICAL SIGNALS AND VEHICLE PARAMETERS MONITORING SYSTEM FOR EMERGENCY PATIENT TRANSPORTATION

Keywords: Electronic Patch, Wireless Reflectance Pulse Oximetry, SpO2, Heart Rate, Body Temperature.

Soil Moisture Control Using RF Transreceiver

ADVANCED EMBEDDED MONITORING SYSTEM FOR ELECTROMAGNETIC RADIATION

2.4GHZ CLASS AB POWER AMPLIFIER FOR HEALTHCARE APPLICATION

WIRELESS RF TRANSCEIVER FOR ENERGY METER READING SYSTEM

Intelligent Bus Tracking and Implementation in FPGA

A Microcontroller Based Smart Helmet Using GSM &GPS Technology in Construction Sites

A Solar-Powered Wireless Data Acquisition Network

WRIST BAND PULSE OXIMETER

Chest Worn Pulse Oximeter Integrating NI-USRP with GPS Disciplined Clock Transceiver

RF(433Mhz) BASED PROJECTS


Embedded Prototype System for Monitoring Heart Rate

Implementation of Fall Detection Positioning and Rescue System Using Smart Phone

Novel Industrial Data Acquisition System Using IOT

USTGlobal. Internet of Medical Things (IoMT) Connecting Healthcare for a Better Tomorrow

Monitoring and Protection of Distribution Transformer Using GSM Module Jenifer A 1, Bharathi B R 2, Shanthi Mounika B 3

Design Of Low-Power Wireless Communication System Based On MSP430 Introduction:

SOLDIER NAVIGATION AND HEALTH RECORDING SYSTEM USING IOT

Design and Implementation of Integrated Smart Township

Embedded & Robotics Training

E-health Project Examination: Introduction of an Applicable Pulse Oximeter

common type of cardiac diseases and may indicate an increased risk of stroke or sudden cardiac death. ECG is the most

Modern Electricity Billing System and Fuse Detection Using GSM

REMOTE ENERGY METER MONITORING WITH SMS

ROBOT FOR BIOMEDICAL APPLICATIONS CONTROLLED BY REGIONAL LANGUAGE

REVIEW ON-IOT BASED SMART HEALTHCARE SYSTEM

Mobile Agent Based Intelligence Power Distribution Control System

Ahmad Faraz Hussain 1, Polash Kumar Das *1, Prabhat Ranjan 1 1 School of Electronic and information, South China University of Technology Guangzhou,

International Journal of Scientific Research and Reviews

Design and Development of Blind Navigation System using GSM and RFID Technology

Automatic Load Sharing of Transformers using Microcontroller

Design and Implementation of Low Cost ECG Monitoring System and Analysis using Smart Device

Arm Based Remote Monitoring and Control System for Environmental Parameters in Greenhouse

Healthy Sport Monitoring System

REMOTE HEALTH MONITORING SYSTEM USING PIC MICROCONTROLLER

School of Electronic Science and Engineering, Nanjing University of Posts and Telecommunications, Nanjing, , China

Economical Way of GPRS Based Fully Automated Energy Metering System

The report presents the functionality of our project, the problems we encountered, the incurred costs and timeline for the project development.

ATB200. Datasheet. ATB200 GPRS / GPS based Fleet Management Terminal. 1

A XBEE based WSN with GSM Technology to Monitor Paddy Field Environment

RFID Integrated Teacher Monitoring

Follow this and additional works at: Part of the Engineering Commons

A Heart Rate Measurement using Bioimpedance

Transcription:

Research Article JOURNAL OF ADVANCEMENT IN ENGINEERING AND TECHNOLOGY Journal homepage: http://scienceq.org/journals/jaet.php Development of a GSM Based Health Monitoring System for Elderly People Ahmed A. 1, Olaniyi, O.M. 2, Folorunsho, T. A. 3 and Okogbe, O. J. 4 Department of Computer Engineering, Federal University of Technology, Minna, Niger State, Nigeria *Corresponding author: Ahmed A.. E-mail: aliyu.ahmed@futminna.edu.ng Received: June 12, 2015, Accepted: August 8, 2015, Published: August 8, 2015 Open Access ABSTRACT Advancement in wireless communication has set a new paradigm in healthcare management system which is based on sensing vital physiological parameters, collection of data and transmission of that data in real time and with optimum precision. Going to the hospital every day for medical checkup can be tiresome, stressful and it also brings about the problem of congestion of hospital space and beds. Lack of human resources at the hospital aids the congestion of hospital space. This paper is based on monitoring physiological parameters of elderly people. A reliable and cost effective GSM based health Monitoring System is developed in this paper. The result obtained showed that the system is reliable and efficient with an average sensitivity of 0.5 seconds and response time of 6 seconds. The system is able to monitor heartbeat and blood pressure and send the data in real time to the mobile phone of the doctor. It enables the doctor to keep track of his patient s health. Keyword: GSM, Health Monitoring, Elderly, Wireless Communication, Body Area Network. INTRODUCTION Health monitoring of elderly people has been an issue for healthcare sector over the years because they are more prone to chronic diseases and require regular checkup. According to [1] the population of elderly people above the age of 65 years across the world is more than 650 million people and this large number will double in the next decade. Health monitoring has been faced with problems such as the lack of human resources to attend to patients, patients information not easily accessed by their doctor, congestion of hospital space and beds. Health monitoring systems make use of biomedical sensors which continuously and in real time check for various physiological parameters of the patient. For proper management of healthcare, patients need to be educated on how to manage their health. Quality and healthy life style include good support of human health monitoring and assessment [2]. Advancement in technology contributed immensely to healthcare management. Modern Intensive Care Units have presented an outstanding range of technologically sophisticated instrumentation to produce a broad measurement of the physiological state of each patients. A number of bio-sensors that monitor physiological signs, enviromental conditions (temperature, humidity and light), and a location sensor can all be incorporated in a wearable wireless body area network. Body area networks are inexpensive, have light weight, offer long-term, unobtrusive, ambulatory health monitoring in real time. In order to keep track with patients health status a health monitoring system based on GSM is designed and implemented in this paper. The system will be applicable in remote areas such as villages where the indigenes are out of reach from experienced physicians and the city. This paper is structured as follows. Section 2 presents the review of related works while the model architectural design is presented in section 3, and the performance evaluation of the model was carried out in section 4. Section 5 concludes the paper. Numerous authors have worked to achieve a standard health monitoring system. [3] developed a GSM Based Heart Rate and Temperature Monitoring System for continuous monitoring of the patient condition especially in the case of old people who are suffering with heart diseases or cases where the patient location is far away from the hospital. The system measures the heart beat of the patience using a parallel arrangement of LEds and LDrs which harnesses the systolic pressure qualities of the fingeer tip, also an LM35 is used to measure the temperature which are them transmitted through a GSM modem to the doctor or medical center. The system provides a low cost solution by utilizing the AT89S52 Microcontroller, however, the system lacked redundancy incase of network downtime. [4] also developed a mobile health monitoring system that uses the GPRS technology. With the advent of Personal mobile devices which is becoming more equiped with information management, processing and sharing tools it presents a very good opportunity for the developmet of a mobile, user friendly and unobtrusive health monitoring system. Specifically, the system unlock existing ones resident and added Intensive Care Units of hospitals. It is mobile, it measures patients body temperature and heartbeat, compares it to a previously determined values, if extreme values are detected the system relays the information to a nearby mobile phone which then sends an SMS to the doctor containing the parameter readings and location information via gprs. The system does not measure blood pressure reading which is very important. [1] proposed an improved Remote Patient Monitoring (RPM) systems equipped with wireless capabilities. The system is expected to monitor patient s vital signs and transmit them via wireless channels like Bluetooth, zigbee or other Wi-Fi link to the doctor s mobile phone along with a camera enabled live feed of the patient s condition. Unlike previous works, this proposal is not cost effective and it is expected to be used within a short range. It J. of Advancement in Engineering and Technology Voume3 /Issue2 ISSN: 2348-2931 1

utilizes a readily available AVR microcontroller and IDE. An attached server unit is expected to also receive all sensor data, process it and store before sending the information to the doctor. This storage functionality is a very vital improvement. Meanwhile, [5] developed Wireless Biomedical Sensor Network for Home-based ECG Monitoring system. This system utilizes a mote platform for Wireless Biomedical Sensor Network (WBSN), named Telekom Research Group (TRG) mote that complies with IEEE802.15.4 standard and operates in 2.4 GHz ISM band. The platform is designed by hardware and software implementations. Since energy consumption is a major concern for any wireless sensor network, the mote design utilizes a low power 8-bit PIC18F452 microcontroller and XBee wireless transceiver module. This system measures only heartbeat rate and is highly expensive. [6] developed a system based on continuous monitoring of ICU patients. The system is a reliable, energy efficient patient monitoring system. It is able to send parameters of patient in real time. It enables the doctor to monitor patient s parameters (temperature, heartbeat and ECG) in real time using http protocol. The timely manner of conveying real time monitored parameter to doctor is given highest priority. The system is not cost effective and does not monitor blood pressure which is a vital parameter. Our proposed model for GSM based health monitoring system improves on the deficiencies in [3], [4] and [6] by using a buzzer to checkmate the problem of network downtime and blood pressure sensor was incorporated into the system for blood pressure monitoring. The developed system monitors blood pressure and heartbeat rate in real time with optimum precision. METHODOLOGY System Design The model as shown in Figure 3.1 interfaces a GSM module with sensors (heartbeat and blood pressure) for real time monitoring of patients physiological status. The operation of the system is such that the sensors send signals to the microcontroller which then interpret the signals and send the output to the mobile phone of the doctor. The standard values are already stored in the microcontroller so if there is any abnormal reading, the buzzer incorporated in the system will ring an alarm and an SMS will be sent to the mobile phone of the doctor. The system functions with both AC and DC supply. The flowchart in Figure 3.1 describes the entire operation of the system. The transmission unit houses the GSM module which is configured using AT commands. It is connected to RC6 (TX) and RC7 (RX) of the microcontroller serial input and output ports/pins and these enable the microcontroller to send SMS to the designated recipient the input readings from the sensors. A SIM900 GSM module was used for this project because of its availability. The transmission unit also housed an LED. The status LED consist of an LED connected to PortB0 of the microcontroller. This is used to indicate that the system has sent an SMS. The sensor unit of this system comprised of LM358 IC and a 555 timer. The 555 timer was used for pulse generation while the LM358 IC was used for amplification and as a comparator. The LM358 amplifies the sound from the heartbeat and the variation of the beat. It has dual low power amplifier. When the heart beats, a pressure wave moves out along the arteries at a few meters per sound. This pressure wave can be felt at the wrist, but it also causes an increase in the blood volume in the tissues which can be detected by a 555 timer. The amplified signal from the LM358 to the microcontroller is then converted by the ADC and the calculation is performed by microcontroller. Filtering is needed to block any higher frequency noise present in the signal. The software used serves as the domain for the control of the hardware. It is the set of instruction that is used to configure the hardware. The control program for this model was written in CCS language. The CCS program implements the flowchart described in Figure 3.1. Simply put, it reads in binary patterns from the input system and sends out binary patterns that would cause the required actions to be taken by the output system. System Hardware The hardware system comprises of different units which perform different functions to meet the objectives of the system. The units are: The power unit, the sensor unit, transmission unit and the Control Unit. Power Supply Unit: The power supply unit is used to provide regulated DC voltages for electronic circuits. A 12V Transformer was used to step down 220V from the mains to 12V which is connected to the rectifier that converts the 12V A.C to D.C. A capacitor (Electrolytic) of 10uF 50V is used to filter A.C ripples from the D.C. Regulator (7805), regulates 12V DC to 5V DC for use by the microcontroller and other components. The choice of the transformer for the power supply unit was decided based on the following: Output Voltage (to the load) = 5V DC since a 7805 voltage regulator was used. Diode voltage drop = 0.7V per diode. Transformer losses = 1.1v Therefore, minimum input voltage = (5 + 2.5) V = 7.5 The block diagram of the power supply unit is shown in Figure 3.2. But again this system uses a 9V battery as the power source through the power supply so that the system will remain on and working even if the ac power source is gone or unplugged the dc power through the 9V battery will keep the system functionality on until the power in the battery is drained. Figure 3.1: Flowchart of the System Figure 3.2: Block Diagram of Power Supply Unit J. of Advancement in Engineering and Technology Voume2 /Issue4 ISSN: 2348-2931 2

Sensor Unit: Transducers are used for measurement of electrical, thermal, mechanical and chemical properties. A transducer is any device that convert non-electrical signal into electrical signal (voltage or current) that are proportional to the value of the physical parameters being measured. Transducers are divided into two classes namely: sensors and actuators. Sensors are devices that sense, detect or measure real-world conditions such as heat, light and convert it into an analogue or digital representation. The sensor unit of this system comprised of LM358 IC and a 555 timer. The 555 timer was used for pulse generation while the LM358 IC was used for amplification and as a comparator. The LM358 amplifies the sound from the heartbeat and the variation of the beat. It has dual low power amplifier. When the heart beats, a pressure wave moves out along the arteries at a few meters per sound. This pressure wave can be felt at the wrist, but it also causes an increase in the blood volume in the tissues which can be detected by a 555 timer. The amplified signal from the LM358 to the microcontroller is then converted by the ADC and the calculation is performed by microcontroller. Filtering is needed to block any higher frequency noise present in the signal. The amplification circuit is shown in Figure 3.3. Figure 3.5: LED Indicator Circuit The forward voltage drop of LED s is 2V and forward current of 13.6mA. From Ohm s law, Therefore, R = 220.5 Ohm s. The Control Unit: This unit controls the system. It collects signals and directs the operation of the output unit by providing the timing and control signal. The control unit used in this research is PIC16F887 microcontroller with 40 pins shown in Figure 3.6. The overall circuit diagram of the system designed is shown in Figure 3.7. Figure 3.6: Pin Diagram of PIC16F887 Figure 3.3: Amplification circuit Transmission Unit: The transmission unit houses the GSM module which is configured using AT commands. It is connected to RC6 (TX) and RC7 (RX) of the microcontroller serial input and output ports/pins and these enable the microcontroller to send SMS to the designated recipient the input readings from the sensors. A SIM900 GSM module shown in Figure 3.4 is used for this work because of its availability and functionality. Figure 3.7: Circuit Diagram of the System System Implementation The system is firstly simulated on a breadboard for design adherence and performance check before implementing it on a Vero board. The system is packaged using glass Perspex. Figure 3.8 shows the finished product being tested. Figure 3.4: SIM900 GSM Module The transmission unit also houses an LED. The status LED consist of an LED connected to PortB0 of the microcontroller. This is used to indicate that the system has sent an SMS. The circuitry below shows how the LEDs are connected and how the limiting current resistor value is obtained is shown in Figure 3.5. Figure 3.8: Snapshot of Developed Module J. of Advancement in Engineering and Technology Voume2 /Issue4 ISSN: 2348-2931 3

TESTING AND RESULT Evaluation of the system is based on sensitivity, accuracy and response time to determine the reliability and efficiency of the system. Testing for sensitivity is to define how long it takes the system to respond to changes in physiological data and how fast it detects pulse, while, accuracy measures the closeness of the values obtained by the system to standard values for a healthy person. Response time deals with the length of time it takes for the message sent to get to the recipient. Table 1 shows the results obtained for 4 different sample runs from different individuals using two systems for Heart Beat Rate and Blood Pressure. The error rate is calculated from the raw data using: Formula for error % = (project reading existing system reading) (existing system reading) 100 Test Project (BPM) Existing System (BPM) Table 1. Result Obtained Error Rate Project (%) (mmhg) Existing System (mmhg) Sample 1 72 73 1.37 101/60 103/62 2.59 Sample 2 76 80 5.00 100/63 101/62 1.30 Sample 3 67 69 2.90 107/72 106/73 1.16 Sample 4 81 84 3.57 115/70 117/73 2.91 It was observed that some readings vary due to some factors like unstable power, movement of the body when the sensor is placed on the users wrist. From the percentage error derived from the readings, the system is efficient and suitable for use. The sensitivity reading shows how sensitive the sensor is and how fast it collects pulse. The response time readings indicate that the time it took to for the SMS to deliver was fast. Figure 4.1, 4.1 and 4.3 shows the relationship between the results obtained from the developed system and an existing system. The closeness of both results indicates that the developed system is highly efficient. Error Rate (%) Figure 4.3: Graph Comparing Diastolic Blood Pressure Readings from both Devices Figure 4.1: Graph Comparing Heart Beat Rate Readings from both Devices Figure 4.2: Graph Comparing Systolic Blood Pressure Readings from both Systems CONCLUSION The health monitoring system implemented in this paper seeks to eliminate the stress of going to the hospital frequently for checkup, congestion of hospital space and beds. It monitors blood pressure and electrocardiogram and transmit the information to the mobile phone of the doctor via SMS in real time. The results obtained shows that the system is efficient and reliable. The system is cost effective and has ease of use. RECOMMENDATIONS Future researches should look at the following open issues: Enhancement of the system to sense additional physiological parameters other than blood pressure and heart beat rate. A network booster could be incorporated in the system to aid the transmission of data via SMS. A graphical user interface could also be implemented for better user interaction with the system. Also a non-proprietary platform should be explored to ensure more reliability and cost effectiveness. REFERENCES 1. A. K. Bhushan Kulkarni, Mushit Shaik, Akshay Shelke, "Wi-Fi Based Remote Patient Monitoring and Tracking System for Medical Parameters," International Journal of Engineering and Technology, vol. 1, pp. 1-3, 2014. J. of Advancement in Engineering and Technology Voume2 /Issue4 ISSN: 2348-2931 4

2. Lymberis, (2005) Progress in R&D on Wearable and Implantable Biomedical Sensors for Better Healthcare and Medicine, Proceeding of the 3rd annual international IEEE EMBS Special Topic Conference on Microtechnologies in Medicine and Biology. 296-298. 3. S. G. N. V. Subhani Sk. M., Chaitanya Ch., Prakash Babu G., "Implementation of GSM Based Heart Rate and Temperature Monitoring System," Research Journal of Engineering Sciences, vol. 2, pp. 1-3, 2013. 4. M. L. Shubhangi M. Verulkar, "Real Time Health Monitoring Using GPRS Technology," International Journal of Computer Science and Network, vol. 1, pp. 1-8, 2012. 5. M. R. A. R. Rozeha A. Rashid*, S. H. Syed Arifin, S.K. Syed Yusof, Norsheila Fisal, "Wireless Biomedical Sensor Network for Home-based ECG Monitoring," International Journal of Biomedical Engineering and Technology,, 2008. 6. J. B. Jayant Mankar, Nikita Thool, Pranali Rasnala, Komal Handa, "ARM7 Based Patients Health Monitoring System," International Journal of Research in Advent Technology, vol. 2, pp. 1-8, 2014. Citation: Ahmed A. et al.. Development of a GSM Based Health Monitoring System for Elderly People. J. of Advancement in Engineering and Technology. V3I2. DOI: 10.15297/JAET.V3I2.06 Copyright: 2015 Ahmed A.. This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. J. of Advancement in Engineering and Technology Voume2 /Issue4 ISSN: 2348-2931 5