BSWA Impedance Tube Solutions

Similar documents
BSWA SW420R Impedance Tube System

SW Series Impedance Tube Solutions

BSWA Technology. Product Catalogue

Supplementary User Manual for BSWA Impedance Tube Measurement Systems

Microphone Cartridge Model: MP201

P R O D U C T D A T A

PRODUCT DATA. Applications. Uses

PRODUCT DATA USES. BENEFITS Normal incidence parameters are determined Fast and accurate measurements. Type 4206A. Type Type 4206T 50 Hz 1.

Microphones & Accessories

Production Analyzer Rev (USB + FireWire) Rev. 2.x (USB only)

Product and Measurement Solutions for the Automotive Industry

PAVEMENT SURFACE CHARACTERISTICS. Task 3 DEVELOPMENT OF A SOUND ABSORPTION PROTOCOL. Principal Investigator:

Measurement at defined terminal voltage AN 41

PD002. Product Data ZIRCON. Loudspeaker-Microphone Probe

HP590i High Power Coaxial OpenCeiling Speaker. Nominal Impedance. Sensitivity 2.83V/1M Sensitivity 1W/1M (2)

SM400i 4 COAXIAL SURFACE-MOUNT SPEAKER. Nominal Impedance. Sensitivity 2.83V/1M Sensitivity 1W/1M (2)

RF31-EZ-T PREMIUM FULL-RANGE 3-INCH SPEAKER WITH 10 W INTEGRATED TRANSFORMER FOR APPLICATIONS REQUIRING 8 OHM AUDIO SOLUTIONS

Airborne Sound Insulation

Technical Data Measurement Microphones

Real time spectrum analyser sound level meters

Acoustic Calibration Service in Automobile Field at NIM, China

SM82-EZ-II-WX 8 SURFACE MOUNT WEATHERPROOF SPEAKER. Nominal Impedance. Sensitivity 2.83V/1M Sensitivity 1W/1M (2)

Dodecahedron Speaker Set

Coupling / decoupling network (CDN) for screened or coaxial cables

SF 3PT SOUNDFIELD PENDANT SPEAKER SPEAKERS

Group: Names: (1) In this step you will examine the effects of AC coupling of an oscilloscope.

Balanced Armature Check (BAC)

Technical Documentation

18-CHANNEL MOBILE CB TRANSCEIVER MODEL CB-845

3D Intermodulation Distortion Measurement AN 8

IT Series Woofers and Compression Drivers

datasheet Impact 55T IMPACT SERIES ENGINEERING INFORMATION FEATURES APPLICATIONS 70v/100v line transformer with low impedance tap

PB 700 PB 1000 PB 1100 PB 1500 PB 2600 PB 1200 PB 1700 PB 2200 PB 2700 USER'S MANUAL.

CM52-BGM 5.25 COAXIAL IN- CEILING BACKGROUND MUSIC SPEAKER. Nominal Impedance Impedance (min) Sensitivity 2.83V/1M Sensitivity 1W/1M (2)

MC2301. Features and Benefits. Promotional Highlights TUBE POWER AMPLIFIER MCINTOSH LABORATORY INC., 2 CHAMBERS STREET, BINGHAMTON, NEW YORK 13903

Case study for voice amplification in a highly absorptive conference room using negative absorption tuning by the YAMAHA Active Field Control system

Audio Amplifier Frequency Response

High quality audio solutions - all you need for an amazing sound experience. Classic Car Audio

In situ assessment of the normal incidence sound absorption coefficient of asphalt mixtures with a new impedance tube

Experiment P36: Resonance Modes and the Speed of Sound (Voltage Sensor, Power Amplifier)

CM1001d-T. In-Ceiling Subwoofer. Nominal Impedance

F O R T H E L O V E O F M U S I C LP100 OWNER'S MANUAL AND INSTALLATION GUIDE INTRODUCTION

EXTEND YOUR REACH. Copper Mountain Technologies USB VNAs. S-parameter measurement solutions from 9 khz to 110 GHz Measured parameters from S 11

NEXT-LAB SENSOR Scritto da Administrator Martedì 24 Settembre :01 - Ultimo aggiornamento Mercoledì 20 Luglio :44 NEXT-LAB SENSOR 1 / 7

High intensity and low frequency tube sound transmission loss measurements for automotive intake components

A R T A - A P P L I C A T I O N N O T E

ADSworldwide (AUDIO DESIGN SERVICES LIMITED)

Measurement System for Acoustic Absorption Using the Cepstrum Technique. Abstract. 1. Introduction

FLEXUS fx100 AU D I O A N A LY Z E R AUDIO TEST & MEASUREMENT SOLUTIONS. Analog & Digital Audio. Fast Measurements.

Loop & Magnetic Field Coil

Causes for Amplitude Compression AN 12

COUPLING / DECOUPLING NETWORK (CDN) CDN AF TYPE, CDN CAN

G.R.A.S. Sound & Vibration

XAP GWARE 119 M A T R I X. Acoustic Echo Canceller

NEW FROM PCB. Sensors & Instrumentation for Measuring Vibration, Sound, Torque, Pressure, Force, and Strain

STORE BACKGROUND AUDIO SYSTEM. commercial media systems. MOOD: Amplifier Pre-amplifier MOOD: Ceiling Speakers* For use by trained installers only

Features: Description

Series GLET Accessory for dataloggers series GL in modular enclosure

Minirators MR-PRO / MR2

INSTALLATION MANUAL MULTICAST SPEAKER/ EXTREMECAST SPEAKER

8000 Series. Operating Manual Genelec 8040A and 8050A Monitoring Systems

Studio. PRO High Performance Professional Audio MODEL:PA105/PA205 PA AMPLIFIER

Investigating Electromagnetic and Acoustic Properties of Loudspeakers Using Phase Sensitive Equipment

Overview. Features. Technical Data Sheet 1 / 6. Portable PA Systems STAGEPAS 400BT

Shadow. All Weather Loudspeakers

Overview. Features. Technical Data Sheet 1 / 6. Portable PA Systems STAGEPAS 600BT

CLIO Pocket is Audiomatica's new Electro-Acoustical Multi-Platform Personal measurement system.

Advanced Test Equipment Rentals ATEC (2832)

CALRAD 25 series - potentiometers

PRODUCT DATA. 16-channel DeltaTron Conditioning Amplifiers Types 2694-A/B/C/D. Features and Uses

Installed Radio Testing with the 3500

Coupling- / Decoupling Network. 150 khz 300 MHz. 150 khz 230 MHz. 10 khz 230 MHz. IEC and CISPR 15 / CISPR 22 IEC

Acoustic Resonance Lab

USound GmbH. MEMS-based microspeaker. headphones, wearables and array applications

Call/Talk. GAI-Tronics Call/Talk communication systems. GAI-TRONICS A Hubbell Company

SAGA PRO SERIES STEREO POWER AMPLIFIER OPERATION MANUAL

Hegel H2A High End Power Amplifier

F O R T H E L O V E O F M U S I C SERIES 218 DPS200 OWNER'S MANUAL AND INSTALLATION GUIDE INTRODUCTION

Q-Tech. Q-Tech Commercial Series QTA 1360P/1480P Power Amplifiers. User Manual

Noise Excitation Equipment for Building Acoustics Measurements Loudspeaker Systems Nor275 and Nor276 Power Amplifier Nor280 Tapping Machine Nor277

Measuring Instrument Combinations

NEW FROM PCB. Sensors & Instrumentation for Measuring Vibration, Sound, Torque, Pressure, Force, and Strain

SoundCheck 12.0 Quick Start Guide

Coupling/Decoupling Networks (CDN)

SoundCheck 11 Quick Start Guide

TELIKOU Intercom System

TOA PROFESSIONAL POWER AMP

A Desktop Procedure for Measuring the Transmission Loss of Automotive Door Seals

CONCERT-1 CONCERT-2. Instrument DI. The World s Finest Transformers

DX AM FM SSB CW PA Amateur Base Station Transceiver OWNER S MANUAL RX / TX 2 4 POWER NF CHANNEL MODE RF POWER OFF CAL OFF OFF CALIBRATE

SC101. Class 1 integrating sound level meter with measurement. Applications Includes measurement protocols for: Noise generated by motor vehicles

Application overview. Commercial Audio Solutions. boschsecurity.com

87415A microwave system amplifier A microwave. system amplifier A microwave system amplifier A microwave.

User Manual. MA 240 Mixing amplifier

AtlasSound.com 1/8 AF " 1.375" 4.125" 2.375" 2.75" 140 Watt Autoformer AF140. Note: The wire colors are for identification purposes only.

200GTL ALIGNMENT REVISION: 1.0 BURKE MODEL: 200GTL REVISION: 1.2 DATE: 02/14/06. Total Pages: 6 pages. Page:1 print date: 9/23/09

Progress driven by research

Audio. Audio. DB1100 Active DI Box CABLES. Hot Wires Microphone Cables. Hot Wires Instrument Cables. Hot Wires Pro Instrument Cables

MGA Magnetic field system. DC khz

Application Note. Airbag Noise Measurements

Transcription:

BSWA Impedance Tube Solutions Version: 20008

BSWA Company Introduction Established in 998, BSWA Technology Co., Ltd. is becoming the preferred supplier for acoustical measurements. With headquarter located in Beijing, BSWA currently employs 00 staffs with branch offices in Shanghai, Guangzhou, and Chengdu. BSWA s products are distributed in over 40 countries through our sales partners. BSWA Products cover a full range of acoustic measurement devices. The products are sorted into easy-to-follow sections: Microphones Sound level meter Measuring systems Material testing Audio testing Outdoor monitoring systems Sound sources Cable and accessories Impedance Tubes BSWA SW series Impedance Tubes can accurately measure sound absorption coefficients and impedance according to relative ISO and ASTM standards. They also support the sound transmission loss measurements based on the Transfer Function Method. The Transfer Function Method separates the incident and reflected energy from the measured transfer function, and then estimates the acoustic properties of the tested sample installed in the tube. The SW series Impedance Tubes are specially designed not only to work with the cut samples, but also for direct use in the field. The small size and durable aluminum construction make it easy to be transported and used for estimating the properties of walls, ceilings, installed building materials, road surfaces, different ground surfaces, interiors of vehicles, and etc. BSWA offers the complete set of Impedance Tube system, which includes: the tubes, microphones; DAQ hardware and measurement software. BSWA /4 microphones MPA46, which have excellent phase matches, are ideal for impedance applications. The microphones are directly connected to optional 2-channel MC3522 or 4-channel MC3242 data acquisition hardware. PA50 power amplifier is used to drive the loud speaker in the impedance tube. The BSWA VA-Lab software provides all measurement functions for sound absorption and transmission loss testing. Specifications BSWA IMPEDANCE TUBES Model SW230 SW260 SW420 SW470 SW422 SW477 Value to be Measured Sound Absorption Coefficient (α) Sound Absorption Coefficient (α) and Transmission Loss(TL) Standard GB/T-8696, 2-2002, ISO0534-2, 998, ASTM E050-08 Sound Absorption Standard: GB/T-8696, 2-2002, ISO0534-2, 998; ASTM E050-08 ASTM E26-09 Frequency Range (Hz) 25 ~ 350 25 ~ 6300 63 ~ 800 800 ~ 6300 63 ~ 800 800 ~ 6300 Inner Diameter of Testing Tube 60 mm 60 & 30 mm 00 mm 30 mm 00 mm 30 mm Loud speaker 4 in diameter, 20 Watts, 8 Ohm OPTIONAL ITEMS /4 Microphone MPA46 Data Acquisition Card MC3022+PA50 or MC3522 MC3242 Power Amplifier Software VA-Lab2 Basic + VA-Lab2 IMP-A VA-Lab4 Basic + VA-Lab4 IMP-AT PA50 /4

Material Testing System BSWA VA-Lab software has the Impedance Tube Module (VALab IMP) which supports sound absorption and sound insulation measurement for BSWA SW series impedance tubes. The software works with BSWA MC3022, MC3522, MC3242 and MC3642 hardware for data acquisition and analysis. The VA-Lab IMP supports two methods to measure the absorption coefficients of material: Method using Standing Wave Ratio (ISO0534-) Transfer Function Method (ISO0534-2, ASTM E050-08, and ASTM E26-09) The VA-Lab IMP also supports four microphones method for sound transmission loss measurements Impedance TubeSystem for Sound Absorption Measurement Impedance TubeSystem for Transmission Loss Measurement 2/4

Software Interfaces Microphone Calibration Interface Impedance Tube Measurement Interface Impedance Tube Setting Interface Data Combination Interface 3/4

Typical Complete Setup for Measurement of Sound Absorption and Transmission Loss (Frequency Range: 63 Hz ~6300 Hz) BSWA IMPEDANCE TUBE SYSTEM SW422+SW477 # PRODUCT PART # DESCRIPTION NUMBER Impedance tubes, SW422 is of 00mm inner diameter and SW477 of SW422+SW477 30mm inner diameter. For accurate measurement of sound absorption coefficients and transmission loss(63 ~ 6300 Hz) 2 PA50 Power Amplifier of 50W, to power the loudspeaker in the impedance tube 3 MC 3242 Analyzer with 4 ICP input channels and 2 signal output channels, USB powered, 0 ~ 20kHz, to be connected with laptop 4 MPA 46 /4" microphone with Integrated ICP Preamplifier 4 5 CBB005 BNC to BNC cables, 5m, to connect PA50 to MC3242 6 CBS005 BNC to SMB cables, 5m, to connect MPA46 to MC3242 4 7 CAA002 8 CA5 9 VA-Lab4 BASIC 0 VA-Lab4 IMP-AT 2m cable of banana connectors, to connect PA50 to the loudspeaker in the impedance tube Sound Calibrator, 000Hz, 4dB, Type 2, with adaptor for /2'' and /4'' microphones Base software module for measurement of noise and vibration, used for 4- channel analyzer Software module for measurement of material impedance values (4 mics are needed), for measurement and the calculation of Sound Absorption and Transmission Loss of material. 4/4