B15A SERIES BRUSHLESS SERVO AMPLIFIERS Models: B12A6, B15A8

Similar documents
B15A SERIES BRUSHLESS SERVO AMPLIFIERS Models: B12A6, B15A8, B15A20

BDC30A SERIES BRUSHLESS SERVO AMPLIFIERS Models: BDC30A8, BDC40A20

SERIES 100A SERVO AMPLIFIERS MODELS: 100A25, 100A40

SERIES 50A SERVO AMPLIFIERS Models: 30A8, 25A20, 50A8, 50A20

B25A20FAC SERIES BRUSHLESS SERVO AMPLIFIERS Model: B25A20FAC 120VAC Single Supply Operation

SR30A-AC SERIES BRUSHLESS SERVO AMPLIFIERS Model: SR30A40AC

PRELIMINARY AVB250A060 PRELIMINARY. Servo Drive. Peak Current (10 seconds)

S100A40AC SERIES BRUSHLESS SERVO AMPLIFIERS Model: S100A40AC

AxCent Servo Drive AZBE10A4IC

Analog Servo Drive BD15A8

CURREN T LINIT CURRENT " Sold & Serviced By:

Analog Servo Drive 20A20

Peak Current. Continuous Current. See Part Numbering Information on last page of datasheet for additional ordering options.

BD30A SERIES BRUSHLESS SERVO AMPLIFIERS Models: BD30A8, BD25A20

AxCent Servo Drive A50A100

Analog Servo Drive 30A8

AxCent Servo Drive A25A100

Analog Servo Drive 30A8

Analog Servo Drive 30A20AC

Analog Servo Drive B25A20

Analog Servo Drive 100A40

Analog Servo Drive 10A8

AxCent Servo Drive AB50A200 Peak Current

DIGIFLEX DIGITAL SERVO DRIVES MODEL: DQ111EE40A8BDC

Analog Servo Drive B30A40

M/V Series Servo Drive AB250A060

SERIES Z12A PWM SERVO AMPLIFIERS Models: Z6A6, Z12A8 Micro Series

Analog Servo Drive. Features

AxCent Servo Drive AB25A100

Peak Current. Continuous Current. See Part Numbering Information on last page of datasheet for additional ordering options.

DIGIFLEX DIGITAL SERVO DRIVES MODEL: DQ111EE30A40NAC

Servo Systems Co. 53 Green Pond Road, Suite #2 Rockaway, NJ (973) Toll Free: (800) Fax: (973)

Analog Servo Drive 25A20DD

Analog Servo Drive B30A40AC

Analog Servo Drive. Peak Current 16 A (11.3 A RMS )

Analog Servo Drive B60A40AC

Analog Servo Drive. Continuous Current. Features

Digital Servo Motor Driver

DigiFlex Performance Servo Drive B100A400AC

All drive and motor parameters are stored in nonvolatile. Features

MMP SA-715A SERVO AMPLIFIER

Logosol AC/DC Servo Amplifier LS-58P Doc # / Rev D, 07/17/2008

Servo Amplifier PMA 90 / 180

Logosol AC/DC Servo Amplifier LS-57P

DigiFlex Performance Servo Drive DPQNNIE-030A800

815-BR SERVO AMPLIFIER FOR BRUSH SERVOMOTORS

AxCent Servo Drive B100A400AC

DigiFlex Performance Servo Drive DZCANTE-020L080

DigiFlex Performance Servo Drive DPRAHIR-060A400

DigiFlex Servo Drive DPQNNIE-060A400

DynaDrive INFORMATION MANUAL SDFP(S)

Ethernet. DigiFlex Performance Servo Drive DPMANIU-020B080. Click&Move Embedded

DigiFlex Performance Servo Drive DPRAHIE-015S400

DigiFlex Performance Servo Drive DPCANIA-060A400

Variateur analogique courant continu série AZ et AZB

Servo Amplifier 4-Quadrant PWM for Brushless DC-Servomotors

DigiFlex Performance Servo Drive DPRANIE-040A400

1525-BRS INFORMATION MANUAL SERV O D YN A M ICS. D y n ad r iv e Ave Crocker Suite 10 Valencia, CA

Logosol AC/DC Intelligent Servo Drive for Coordinated Control LS-174WP

Compact, Low-Cost Solutions

BMC 6C & 7D HARDWARE INSTALLATION MANUAL. MCG Inc. BMC 6C & 7D Hardware Installation Manual ZN2UDB6799-4

Logosol Intelligent Hall-Servo Drive LS-173U Doc # / Rev. C, 02/12/2008

SCS Automation and Control Ltd

DigiFlex Servo Drive DPQNNIE-015B200

Ethernet. DigiFlex Performance Servo Drive DPMANIU-040A400. Click&Move Embedded

DigiFlex Performance Servo Drive DPEANIU-015S400

Servo Systems Co. 53 Green Pond Road, Suite #2 Rockaway, NJ (973) Toll Free: (800) Fax: (973)

Motion Controller 2-Quadrant PWM for Brushless DC-Servomotors

DeviceCraft Revision #1 11/29/2010

FEATURES DESCRIPTION THE OEM ADVANTAGE

MSK4310 Demonstration

Dynamo Brushless DC Motor and GreenDriveTM Manual

Ametek, Inc. Rotron Technical Products Division. 100 East Erie St., Suite 200 Kent, Ohio User's Guide. Number Revision F

MODEL 513, 513R DC BRUSHLESS SERVO AMPLIFIER (513) WITH RESOLVER OPTION (513R) FEATURES. ±180 Volts at ±26A Peak, ±13A. Resolver option 513R

DigiFlex Performance Servo Drive DPEANIU-C100A400

DigiFlex Performance Servo Drive DPEANIU-030A800

Designated client product

30-80V, 8.2A Peak, No Tuning, Nulls loss of Synchronization

MODEL 503 DC BRUSHLESS SERVO AMPLIFIER

MODELS 4122, 4212 DC BRUSH SERVO AMPLIFIERS

ASC. Accelus Card. Model Ic Ip Vdc ASC ASC

SCA-SS (70V, 10A)

Illustration 1: Wiper Motor Controller, Sensor, and optional programmer. DC Wiper Motor H-Bridge Servo / Speed Controller

INTEGRATED CIRCUITS. AN1221 Switched-mode drives for DC motors. Author: Lester J. Hadley, Jr.

maxon motor maxon motor control 1-Q-EC Amplifier DEC 24/1 Order numbers , , , ,

Installation Tech Note Dallas, Texas

BRUSHLESS DC MOTOR FAMILY

High Performance Blowers

XC4e PWM Digital Drive

BLuAC5 Brushless Universal Servo Amplifier

ES86 Series Closed-loop Stepper Drive + Motor System (ES-D808 Drive+ Motor/Encoder)

XC4 PWM Digital Drive

XC4e PWM Digital Drive

BLuAC5 Brushless Universal Servo Amplifier

MODELS 7225AC, 7425AC LINE-POWERED AC BRUSHLESS SERVO AMPLIFIERS WITH ±10V ANALOG U-V INPUTS

ES86 Series Closed-loop Stepper Drive + Motor System (Drive+ Motor/Encoder)

Datasheet of the MEZ Stepper Servo Drive MEZ 2D VDC, 8.2A Peak, Closed-loop, No Tuning. Version

BAP1551 Gate Drive Board

DigiFlex Performace DPR Drives. RS485 and Modbus RTU Communication. Hardware Installation Manual ORIGINAL INSTRUCTIONS. Everything s possible.

The motors are described by the following numbering system: D 500 ppr encoder 1 E 1,000 ppr encoder 1 H Hall-effect only R resolver

Transcription:

B15A SERES BRUSHLESS SERVO AMPLFERS Models: B12A6, B15A8 FEATURES: Surface-mount technology Small size, low cost, ease of use DP switch selectable: current, open loop, or tachometer velocity mode Four quadrant regenerative operation Agency Approvals: BLOCK DAGRAM: ADVANCED MOTON CONTROLS 3805 Calle Tecate, Camarillo, CA 93012 Tel: (805) 389-1935, Fax: (805) 389-1165 C-5

DESCRPTON: The PWM servo amplifiers are designed to drive brushless DC motors at a high switching frequency. A single red/green LED indicates operating status. amplifiers are fully protected against overvoltage, over-current, over-heating and short-circuits. They interface with a digital controller or can be used as a standalone drive. These models requires only a single unregulated DC power supply. Loop gain, current limit, input gain and offset can be adjusted using 14-turn potentiometers. The offset adjusting potentiometer can also be used as an on-board input signal for testing purposes, when SW4 (DP switch) is ON. SPECFCATONS: MODELS POWER STAGE SPECFCATONS B12A6 B15A8 DC SUPPLY VOLTAGE 20-60 V 20-80 V PEAK CURRENT (2 sec. maximum) ± 12 A ± 15 A MAXMUM CONTNUOUS CURRENT ± 6 A ± 7.5 A MNMUM LOAD NDUCTANCE* 200 µh 200 µh SWTCHNG FREQUENCY 33 khz ± 15% HEATSNK (BASE) TEMPERATURE RANGE 0 to + 65 C, disables if > 65 C POWER DSSPATON AT CONTNUOUS CURRENT 18 W 30 W OVER-VOLTAGE SHUT-DOWN (self reset) 62 V 86 V BANDWDTH (load dependent) 2.5 khz 2.5 khz MECHANCAL SPECFCATONS POWER CONNECTOR SGNAL CONNECTOR SZE WEGHT Screw terminals Molex connector 5.09 x 2.98 x 0.99 inches 129.3 x 75.8 x 25.1 mm 10 oz. 0.28 kg * Low inductance motors require external inductors. C-6

PN FUNCTONS: CONNECTOR PN NAME DESCRPTON / NOTES /O 1 +10V @ 3 ma OUT For customer use O 2 SGNAL GND Reference ground GND 3-10V @ 3 ma OUT For customer use O 4 +REF N 5 -REF N 6 -TACH N Differential reference input, maximum ±15 V, 40K input resistance Tachometer input, max. ±60 VDC, 60K input resistance 7 +TACH / GND Ground GND 8 CURRENT MONTOR OUT Current monitor. 1 V = 2 A O P1 9 NHBT N This TTL level input signal turns off all power devices of the H bridge when pulled to ground. This inhibit will cause a fault condition and a red LED. For inverted inhibit input, see section "G". 10 +V HALL OUT Power for HALL sensors, short circuit protected, O +6 V @ +30 ma. 11 GND GND 12 HALL 1 13 HALL 2 14 HALL 3 HALL sensor inputs, TTL logic levels, internal 5 KΩ pull-up. Maximum low level input is 1.5 V, minimum high level input is 3.5 V 15 16 CURRENT REFERENCE OUT FAULT OUT (red LED) Monitors the input signal connected directly to the internal current amplifier. 7.25 V = max current. See current limit adjustment information below. TTL level output. Becomes high during output short circuit, over-voltage, inhibit, over-temperature and during power-on reset. Fault condition indicated by red LED. O O 1 MOTOR A Motor phase A connection O 2 MOTOR B Motor phase B connection O P2 3 MOTOR C Motor phase C connection O 4 POWER GND Power ground GND 5 HGH VOLTAGE DC power input C-7

SWTCH FUNCTONS: SWTCH FUNCTON DESCRPTON ON SETTNG OFF 1 Duty-cycle feedback Open Loop No Effect 2 60 / 120 degree commutation phasing setting 120 degree 60 degree 3 Loop integrator. This capacitor normally ensures "error-free" operation in velocity mode by reducing the error-signal (output of summing amplifier) to zero. Shorts out the velocity / voltage loop integrator capacitor. Velocity / voltage loop integrator capacitor operating. 4 Test / Offset. Sensitivity of the "offset" pot. Used as an on-board reference signal in test mode. Test Offset POTENTOMETER FUNCTONS: POTENTOMETER DESCRPTON TURNNG CW Pot 1 Pot 2 Pot 3 Pot 4 Loop gain adjustment in open loop & velocity modes. Turn this pot fully ccw in current mode. Current limit. t adjusts both continuous and peak current limit while maintaining their ratio (50%). Reference gain. t adjusts the ratio between input signal and output variables (voltage, current, velocity). Test / Offset. Used to adjust any imbalance in the input signal or in the amplifier. When SW4 (DP switch) is ON, the sensitivity of this pot is greatly increased thus it can be used as an on-board signal source for testing purposes. See section G. ncreases loop gain ncreases current limit ncreases reference input gain N/A C-8

OPERATNG MODE SELECTON: These modes can be selected by the DP switches according to the chart in the functional block diagram: Current mode Open loop mode Tachometer mode See section "G" for more information. SET-UP: See section "G" for engineering and installation notes. CURRENT LMT ADJUSTMENTS: These amplifiers feature peak and continuous current limit adjustments. Potentiometer 2, the current limiting potentiometer, has 12 active turns plus 1 inactive turn at each end and is approximately linear. Thus, to adjust the current limit turn the potentiometer fully counter-clockwise, then turn clockwise to the appropriate value. P1-15 is the input to the internal current amplifier stage. Since the output current is proportional to P1-15, the adjusted current limit can easily be observed at this pin without connecting the motor. Note that a command signal must be applied to the reference inputs to obtain a reading on P1-15. The maximum peak current value equals 7.25 V at this pin and the maximum continuous current value equals 3.63 V at this pin. Example: Using the B12A6, 7.25V=12A. The actual current can be monitored at pin P1-8. TYPCAL SYSTEM WRNG: See section "G". ORDERNG NFORMATON: Models: B12A6X, B15A8X X indicates the current revision letter. MOUNTNG DMENSONS: See page F-7. C-9

C-10

Mounting Dimensions F-7