INSTALLATION GUIDELINES

Similar documents
INSTALLATION GUIDELINES

INSTALLATION GUIDELINES

CALLAS THERMOSTATIC SHOWER SET

LATTIMORE SHOWER SET INSTALLATION

ONASSIS SHOWER SET INSTALLATION

Pressure Balance Shower Only Dual Control (Volume & Temperature) Ceramic Disc Cartridge Platinum Shower Trim Kit

Installation Instructions

Installation Instructions

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

Installation Instructions

EXIRA SHOWER SET INSTALLATION

Floor-Mounted Tubfiller

MALEKO WALL-MOUNT FAUCET INSTALLATION

Installation Instructions 8115F 8115SF

CAELI THERMOSTATIC SHOWER PANEL

INSTALLATION INSTRUCTIONS

Installation Instructions 3/4 Thermostatic Valve Rough-in & Trim (PL8950)

SHELTON THERMOSTATIC SHOWER PANEL

INSTALLATION INSTRUCTIONS FREE STANDING TUB FILLERS

WILLIS WALL-MOUNT FAUCET INSTALLATION


Installation and Maintenance Instructions

MM540 Installation Instructions IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS

LPK1550 Hydraulic Crimping Tool 15-ton

MantelMount. TM1A Installation Instructions IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS

MM340 Installation Instructions IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS

Frameless Inline Door With Return QCI5263

MM750 Installation Instructions

Preference Collection and Treatment Console INSTALLATION GUIDE

BALANTINE WALL-MOUNT FAUCET INSTALLATION

FIXED SHOWER SCREEN For Wall Mount Hinges QCI5283

Frameless Inline Door QCI5250

ROTUNDA WALL-MOUNT FAUCET INSTALLATION

Power Train Lift Max. Capacity: 1,250 lbs.

Installation/Care/Use Manual Soft Sides Freeze Resistant Fountain

Traditional Wall Mounted Potfiller

GP-SD GENIE PROBE SMALL DIAMETER

INSTALLATION GUIDE 2009-CURRENT HUMMER H3T PRODUCT CODE:

caroma marc newson wall basin mixer

Line volt rail & fixtures. Low volt quick connect fixtures with transformers

INSTALLATION INSTRUCTIONS FOR WALL TUB SETS, TWO HANDLE SHOWER SETS AND WALL LAVATORY SET VALVES NUMBERED: RC & RC

PRODUCT: LOKI INSTALLATION INSTRUCTIONS. Product is covered by U.S. patents. For more information visit

Preference Collection 5543 Central Console INSTALLATION GUIDE

OPERATION AND MAINTENANCE INSTRUCTIONS AVK UNDERGROUND FIRE HYDRANT

INSTALLATION INSTRUCTIONS Y-Connector Accessory (For Multi-Dual Arm Mounting Systems) Model: KSA-1011

GLENBROOK/GLENGUARD VITREOUS CHINA DRINKING FOUNTAIN/CUSPIDOR

Preference Collection 5531 Accessory Console I NSTALLATION GUIDE

INSTALLATION INSTRUCTIONS

ASSA ABLOY Series Installation Instructions. Regular Arm. Parallel Arm. Top Jamb Mount. Multi-Sized 1 thru 6 Non-Hold Open and Hold Open Models

VICTORIAN WIDESPREAD FAUCET

Bodyspray INSTALLATION INSTRUCTIONS

SERVICE INSTRUCTIONS Model 9670 Lubricant Pump

Preference Collection 5580 Treatment Console INSTALLATION GUIDE

Frameless Inline Door QCI5248

CW-1401 (WL1212) CB-1401 (BL1212)

INSTALLATION INSTRUCTIONS 3 BULL BAR 99-04, 04 "HERITAGE" F-150/250LD 2WD, 97-04, 04 "HERITAGE" 4WD WD EXPEDITION/ WD EXPEDITION PART

Fisher 667 Diaphragm Actuator Sizes 30/30i 76/76i and 87

WILLIS WIDESPREAD FAUCET

Frameless Inline Door QCI5254

OB1U INSTALLATION INSTRUCTIONS. Interactive Flat Panel Over White Board Mount

BAÑO Full Pressure Balancing System Shower and Slidebar with. Handshower (Rough & Trim) G-7288-C15S

caroma marc newson shower mixer

FRAMELESS DOOR / PANEL WITH WALL MOUNT HINGES QCI5274

UNIT No FRAMELESS PIVOT SHOWER DOOR

Kwik-Lock. Installation Instructions. Attention Dealers: Please give this owners manual to the customer when the product is delivered.

CV Control Valves Installation and Operation Manual

A-935 RODA WALL MOUNT HINGES

Installation and Assembly - Universal Articulating Swivel Double-Arm for 42" - 60" Plasma Screens

Frameless Heavy Glass Door with Header

Halsey Taylor Owners Manual

Wall-Mounted Basin Set

Universal Projector Ceiling Mount Model: DPM-45

This product is designed for a water supply pressure range of 20 psi (137kPa) minimum to 80psi (550 kpa) maximum.

Barn Door & Hardware Installation Guide

Assembly Instructions 10 X 10 Aluminum Frame Building

INSTALLATION INSTRUCTIONS 960 RODA GLASS TO GLASS HINGES ANGLED FRAMELESS PANEL / DOOR / PANEL CELESTA DRESDEN TRESOR

Maintenance and other important non-personal injury and non-material damage instructions or statements that should be observed.

MODEL 200/220 ASSEMBLY INSTRUCTIONS

Mounting Accessories. Installation Guide. VIVOTEK SD83XXE Speed Dome

Model 209 Fireback Replacement

Rhino Packing Gland Tool

Fixed Wall Arm. Installation Guide. Part number Rev E 2012 PolyVision Corporation All rights reserved

MODEL 1500, 2500 & 2700 MANUAL CONTROLS. Service Manual

SAM. Model: STV-C65 LCD Mobile Visualized Stand Instruction Manual. Weight Capacity: 1251bs / 56.7kg Suits LCD Flat Panel Display: 42"-55" Page 20

Operating, Servicing, and Safety Manual Model # 100 Standard Hydraulic Tubing Notcher Model #100-U Heavy Duty Hydraulic Tubing Notcher

Hollywood Swing Away 2 and 4 Bike Racks Assembly and Installation Guide

18000 HDL FOUR POST LIFT LB CAPACITY INSTALLATION AND OWNER'S MANUAL

Owner s Manual #TSGUARD

Installation and Assembly - Universal Articulating Swivel Double-Arm for 42" - 60" Plasma Screens

PORTABLE ADJUSTABLE BASKETBALL SYSTEM

WHITE ARCHIPELAGO PRESSURE BALANCE MIXING VALVE TRIM ONLY, TO SUIT M ROUGH

Installing a 3 Indexer: Desktop Tools

NRS Installation Manual

HYDRO-TOWER INSTALLATION INSTRUCTIONS

Reliance SG800 Series Steel Water Gage Valves

INSTALLATION INSTRUCTIONS 935 RODA GLASS TO GLASS HINGES FRAMELESS DOOR / PANEL CELESTA DRESDEN GEOLUX TRESOR VONSE

Privacy Wall Glass Selections - Polished Edge Slider Door

Installation Instructions

QB78 CO 2 Pellet Rifle

Transcription:

STYLE No. DSXS20 with 8 Shower Head and Metal Cross Handles STYLE No. DSXS2C System with Metal Cross Handles STYLE No. DSXS30 with 8 Shower Head, Metal Lever and Cross Handle STYLE No. DSXS3C System with Metal Lever Handle STYLE No. DSXS40 with 8 Shower Head, Handshower, Metal Cross Diverter Handle and Metal Cross Handles STYLE No. DSXS2C System with Metal Cross Handles STYLE No. DSHS20 Dash Handshower on Hook with Diverter and Metal Cross Handle STYLE No. DSXS50 with 8 Shower Head, Handshower, Metal Lever Diverter Handle and Metal Cross Handles STYLE No. DSXS2C System with Metal Cross Handles STYLE No. DSHS30 Dash Handshower on Hook with Diverter and Metal Lever Handle STYLE No. DSXS60 with 8 Shower Head, Handshower, Metal Cross Diverter Handle, Metal Lever and Cross Handle STYLE No. DSXS3C System with Metal Lever Handle STYLE No. DSHS20 Dash Handshower on Hook with Diverter and Metal Cross Handle STYLE No. DSXS70 with 8 Shower Head, Handshower, Metal Lever Diverter Handle, Metal Lever and Cross Handle STYLE No. DSXS3C System with Metal Lever Handle STYLE No. DSHS30 Dash Handshower on Hook with Diverter and Metal Lever Handle PAGE 1 OF 11 UPDATED ON 8.23.2018

IMPORTANT: WARNING: This product is large and extremely heavy. It is STRONGLY recommended that 2 or more persons install this product. To ensure this product is installed properly, you must read and follow these guidelines. The owner/user of this product must keep this information for future reference. This product must be installed by a professional licensed contractor and must be onsite prior to rough-in. This allows the installer to visualize the installation and verify the center inlet supply spread. Install accessible hot and cold service stop valves (not supplied) to facilitate servicing. This product is supplied with a THERMOSTATIC VALVE which features anti-scald protection. The risk of scalding exists until the installer has properly calibrated/adjusted the temperature setting during final trim installation. Adequate blocking in the wall is recommended for mounting the THERMOSTATIC VALVE and the SUPPORT POST using the 1-1/2 length WOOD S PROVIDED. DRYWALL ANCHORS, intended for use in a typical 1/2" drywall installation, are provided for situations where blocking is not installed. Be sure your installation conforms to federal, state, and local codes. In the State of Massachusetts, all installations must comply with the rules and regulations set forth within 248 CMR. Inspect this product to ensure you have all the parts required for proper installation. Product is sold partially assembled but shown fully disassembled for illustrative and service purposes only. Use only a strap wrench or protected/smooth-jaw wrench on any finished surface. The use of certain plumber s putty may stain stone or tile surfaces. If further assistance is required, please contact Product Support at 1-800-927-2120 Monday through Friday, 8am 6pm EST. Refer to the separate Service Parts Documents for available replacement parts. TECHNICAL DETAILS: DETAIL ADJUSTABLE VERSUS FIXED SPRAY DIAMETER OF SHOWER HEAD DIAMETER OF HANDSHOWER HEAD (DSXS40, ONLY) DIAMETER OF TUBES THERMOSTATIC HANDLE TURN ANGLE SHUTOFF HANDLE TURN ANGLE DIVERTER HANDLE TURN ANGLE (DSXS40, ONLY) HANDSHOWER HOSE LENGTH (DSXS40, ONLY) INLET CONNECTION INTEGRATED DIVERTER (DSXS40, ONLY) NUMBER OF HOLES PIVOT (SHOWER HEAD ONLY) RESTRICTED MAXIMUM FLOW RATE THERMOSTATIC VALVE MATERIAL WATER PRESSURE RANGE WATER PRESSURE RECOMMENDED SPECIFICATION FIXED 7-3/4 [197mm] 2-3/8 [60mm] 1-1/8 [28mm] ONE AND A HALF TURNS QUARTER TURN QUARTER TURN 59 [1.5m] 3/4" COPPER YES TWO YES 2.5gpm [9.5L/min] WAX ELEMENT 20psi [1.5 bar] MIN 85psi [6.0 bar] MAX 45psi [3.0 bar] PAGE 2 OF 11 UPDATED ON 8.23.2018

ROUGH-IN: Determine the ideal location for the VALVE and INLET ELBOWS based on user preference then, with the HOT supply on the left and the COLD supply on the right, run well supported 3/4" copper supply lines for maximum water flow. WARNING: The inlet supply spread MUST be between 11-1/8 [283mm] MINIMUM and 11-5/8 [295mm] MAXIMUM. Verify the supply lines are secure, level, perpendicular to the finished wall, parallel to each other at the proper spread and at equal depths. The installation will be difficult or impossible if the rough-in is not accurate. Adequate blocking in the wall is recommended for mounting the THERMOSTATIC VALVE and the SUPPORT POST using the 1-1/2 length WOOD S PROVIDED. DRYWALL ANCHORS, intended for use in a typical 1/2" drywall installation, are provided for situations where blocking is not installed. Cap off the supply lines and check for leaks. CAUTION: Make sure when supply lines are cut, the cuts are straight and the edges are free of any burrs. DIM A B C D E VALUE 1-1/8 [29mm] 15/16 [24mm] MAXIMUM 5/8 [16mm] MINIMUM 11-5/8 [295mm] MAXIMUM 11-1/8 [283mm] MINIMUM 48-1/2 [1232mm] MAX (DSXS20, DSXS30 ONLY) 50 [1270mm] MAX (DSXS40, DSXS50, DSXS60, DSXS70 ONLY) 7-1/8 [181mm] BLOCKING [RECOMMENDED] PRE-DRILLED HOLE (x5) "B" FRONT FACE OF TUBE IN FRONT OF FINISHED WALL "D" INLET TO SUPPORT POST BLOCKING SPREAD 3/4" COPPER TUBE [NOT SUPPLIED] "A" FITTINGS HOLE "E" INLET TO VALVE BLOCKING SPREAD FINISHED WALL "C" INLET SPREAD PAGE 3 OF 11 UPDATED ON 8.23.2018

LEVER HANDLE STEM ADAPTER TRIM CONNECTOR DIMENSION "C" [ACTUAL] O-RING [LOOSEN ONLY] 3/4" COPPER LINE GLAND COVER HANDLE BACKPLATE [WITH GASKET] DIMENSION "B" FRONT FACE OF TUBE IN FRONT OF FINISHED WALL LIMIT STOP PLATE STEM ADAPTER PLASTIC BUSHING GLAND COVER LIMIT STOP CROSS HANDLE TRIM PLATE [WITH GASKET] RETAINING COLLAR SET (x3) [2mm HEX] [LOSSEN ONLY] PLASTIC BUSHING [DO NOT REMOVE] TRIM NUT FINISHED WALL 1. THERMOSTATIC HANDLE: a. CROSS: Unthread the then remove the HANDLE and GLAND COVER or, b. LEVER: Unthread the and remove the HANDLE then unthread the and remove the STEM ADAPTER, c. LIMIT STOP: Unthread and remove the PLASTIC BUSHING, loosen, but do NOT remove, the SET S, pull off the LIMIT STOP, unthread the, remove the STEM ADAPTER and LIMIT STOP PLATE. SHUTOFF HANDLE: Unthread the then remove the HANDLE and GLAND COVER. 2. THERMOSTATIC HANDLE: Unthread and remove the RETAINING COLLAR then remove the TRIM PLATE. SHUFOFF HANDLE: Unthread and remove the TRIM NUT, remove the and O-RING, unthread and remove the TRIM CONNECTOR, and remove the BACKPLATE. 3. Measure the actual on-center spread (DIMENSION C) of the LINES, which MUST be between 11-1/8 [283mm] and 11-5/8 [295mm], and ensure the LINES project (DIMENSION B) between 5/8 [16mm] and 15/16 [24mm] from the surface of the finished wall. DIMENSION C [ACTUAL]: PAGE 4 OF 11 UPDATED ON 8.23.2018

[BACK VIEW] PRE-DRILLED HOLE (x4) [MARKED LOCATION] DRYWALL ANCHOR (x4) [OPTIONAL] 3/4" LINE DIMENSION "C" ON-CENTER SPREAD [ACTUAL] FINISHED WALL FINISHED WALL RING (x2) ELBOW (x2) NUT (x2) MOUNTING HOLE (x4) [MARK LOCATION] 3/4" LINE RUBBER WASHER (x2) ELBOW (x2) [ADJUST EVENLY AS NEEDED] [ FRONT VIEW] ELBOW (x2) 4. Push the S against the NUTS then measure the on-center spread of the ELBOWS (DIMENSION C). DIMENSION C [ACTUAL]: IMPORTANT: Verify the ELBOW spread is the same as the LINE spread and, if necessary, adjust the spread by threading and unthreading the ELBOWS from the. CAUTION: Do NOT thread or unthread one ELBOW more than the other. Adjust the ELBOWS evenly and do NOT exceed the MINIMUM or MAXIMUM spread dimensions. 5. Fit the ELBOWS onto the LINES making sure the sits flush against the finished wall then mark the location of the MOUNTING HOLES (x4). NOTE: Do NOT tighten the NUTS, 6. Remove the VALVE and, using the previous marks, predrill holes (pilot holes) to accommodate the MOUNTING S and, if necessary, install the DRYWALL ANCHORS provided where blocking is not installed. PAGE 5 OF 11 UPDATED ON 8.23.2018

s [FLUSH WITH FINISHED WALL] FINISHED CEILING [CLEARANCE] SUPPORT POST 3/4" LINE [MAY BE FIELD CUT] [TOP] C/L COLLAR [ADJUSTABLE HEIGHT] SET [2.5mm HEX] [LOOSEN, DO NOT REMOVE] PRE-DRILLED HOLE [MARKED LOCATION] FINISHED WALL C/L DRYWALL ANCHOR [OPTIONAL] NUT (x2) [MARK LOCATION] [FULLY INSERTED] NUT ELBOW (x2) RING S (x4) 7. Fit the ELBOWS onto the LINES making sure the sits flush against the finished wall and secure the to the wall using the S (x4) provided then thread and securely tighten the NUTS onto the ELBOWS. 8. Fully insert the into the top of the VALVE BODY making sure the for the SUPPORT POST sits flush against the finished wall and there is enough clearance between the top of the ARM and the finished ceiling. Adjust the height, as needed, of the SUPPORT POST COLLAR then mark the location of the. NOTE: If necessary, the may be cut to a desired height, based on the user preference or to ensure enough ceiling clearance. 9. Remove the and loosen, but do NOT remove, the SET on the bottom of the SUPPORT POST then, using the previous marks, predrill a hole (pilot hole) to accommodate the MOUNTING and, if blocking is not installed, install the DRYWALL ANCHOR provided. Mount the to the finished wall using the provided. NOTE: The should be installed with the SET towards the bottom but the orientation may be changed to accommodate difficult installations. PAGE 6 OF 11 UPDATED ON 8.23.2018

: OPTIONAL DSHS20 AND DSHS30 s SUPPORT POST HANDSHOWWER HOOK TOP END MOUNTING PLATE DIVERTER OUTLET ELBOW [RIGHT SIDE INSTALLATION ] SET [2.5mm HEX] SET [2.5mm HEX] SHOWER ARM BOTTOM END [CUT AS NEEDED] NUT PRE-DRILLED HOLE [MARKED LOCATION] The OUTLET ELBOW can be installed on the left side but requires changing VALVE inlet and outlet PLUGS. NUT (x2) DRYWALL ANCHOR [OPTIONAL] STEPS 10 14 OPTIONAL: DIVERTER VALVE WITH HANDSHOWER (PACKAGED SEPARATELY) 10. Determine the ideal and/or desired location for the DIVERTER VALVE and cut the making sure the cuts are straight and the edges are free of any burrs then fully insert the ENDS into the VALVE and securely tighten the NUTS. 11. Fully insert the into the top of the VALVE BODY making sure the SUPPORT POST is fully inserted into the, thread and securely tighten the SET. Thread and securely tighten the NUT on the to the VALVE. 12. Loosen, but do NOT remove, the SET on the HANDSHOWER HOOK to remove the MOUNTING PLATE then determine the ideal and/or desired location for the HOOK and secure the MOUNTING PLATE using the S provided. If blocking is not installed, install the DRYWALL ANCHOR provided. PAGE 7 OF 11 UPDATED ON 8.23.2018

: OPTIONAL DSHS20 AND DSHS30 HANDSHOWER * OPTIONAL SMALL PLUG [WITH O-RING] MOUNTING PLATE HOOK 1. LARGE PLUG [WITH O-RING] 4. SET [2.5mm HEX] OUTLET ELBOW [SWIVEL] HOSE [CONICAL END] [RIGHT HAND] OUTLET ELBOW [360 SWIVEL] [LEFT HAND] [KNURLED END] 2. 3. LARGE PLUG [WITH O-RING] SMALL PLUG [WITH O-RING] 13. Place the HOOK onto the MOUNTING PLATE and securely tighten the SET then connect the HOSE to the HANDSHOWER and DIVERTER VALVE and place the HANSHOWER on the HOOK. NOTE: The DIVERTER VALVE is set for a RIGHT HAND installation of the OUTLET ELBOW. If a LEFT HAND INSTALLATION is desired, the LARGE and SMALL PLUGS must be swapped. 14. Unthread and remove the LARGE PLUG then thread and securely tighten it into the OPPOSITE side of the VALVE. Unthread and remove the SMALL PLUG then thread and securely tighten it into the OPPOSITE side of the VALVE. Ensure both PLUGS are securely tightened to prevent leaks then rotate the OUTLET ELBOW to the correct position. PAGE 8 OF 11 UPDATED ON 8.23.2018

* TURN ON WATER TRIM CONNECTOR HANDLE [SHUT-OFF] ON ON O-RING TRIM NUT OFF BACKPLATE [WITH GASKET] HANDLE [TEMPERATURE] TRIM PLATE [WITH GASKET] RETAINING COLLAR MAXIMUM DESIRED MAX x 1-1/2 TURNS COLD MINIMUM TEMP C/ F HOT TEMP C/ F 15. Slide the BACKPLATE with its RUBBER GASKET over the VALVE with the larger hole towards the bottom then: a. Thread and hand-tighten the TRIM CONNECTOR onto the VALVE. b. Hold the TRIM PLATE against the BACKPLATE then thread and securely tighten the RETAINING COLLAR onto the VALVE. c. Securely tighten the TRIM CONNECTOR and place the and O-RING over the CONNECTOR then thread and securely tighten the TRIM NUT into the CONNECTOR. 16. Turn on the water supply and open the SHUTOFF VALVE to run water through the THERMOSTATIC VALVE, flush out any debris in the LINES, and check for leaks. Slowly rotate the CARTRIDGE STEM on the THERMOSTATIC VALVE clockwise to attain full cold then counterclockwise to attain full hot. It s approximately 1-1/2 rotations. Verify a full range of temperatures exists. MAXIMUM TEMPRATURE: MINIMUM TEMPRATURE: 17. With water running, rotate the CARTRIDGE STEM on the THERMOSTATIC VALVE to adjust the temperature to the maximum desired bathing temperature, verified with a thermometer. Turn the water off and make sure not to change this setting. DESIRED MAXIMUM TEMPRATURE: PAGE 9 OF 11 UPDATED ON 8.23.2018

LIMIT STOP PIN [DO NOT REMOVE] ON GLAND COVER 2. TURN UNTIL STOP AND CHECK MAX TEMP C/ F HANDLE GLAND COVER LIMIT STOP PLATE CROSS HANDLE STEM ADAPTER 1. TURN FULL COLD LIMIT STOP LEVER HANDLE 3. PUSH BUTTON STEM ADAPTER SET (x3) [2mm HEX] PLASTIC BUSHING 18. Place the LIMIT STOP PLATE onto the THERMOSTATIC VALVE in the desired orientation, place the STEM ADAPTER onto the CARTRIDGE and secure it using the provided. Place the LIMIT STOP over the ADAPTER making sure the LIMIT STOP PIN makes contact with the LIMIT STOP PLATE then securely tighten the SET S and thread the PLASTIC BUSHING onto the LIMIT STOP. NOTE: Adjust the position of the LIMIT STOP PLATE to achieve the desired orientation of the LIMIT STOP BUTTON. 4. TURN TO EXCEED MAX TEMP C/ F WARNING: It is NOT recommended to EXCEED a safety limit stop of 37.8 C/100 F 19. Turn the LIMIT STOP to cold then hot and confirm it is functioning properly. Verify the maximum desired bathing temperature. To get a hotter temperature, press and hold the LIMIT STOP BUTTON and turn the LIMIT STOP further. WARNING: It is NOT recommended to exceed a safety limit stop of 37.8 C/100 F. 20. THERMOSTATIC HANDLE: a. CROSS: Place the GLAND COVER onto the LIMIT STOP making sure it is fully seated and place the HANDLE onto the GLAND COVER in the desired orientation then thread and securely tighten the. b. LEVER: Place the STEM ADAPTER onto the LIMIT STOP and secure it using the provided then place the HANDLE over the ADATER in the desired orientation and thread and securely tighten the. SHUFOFF HANDLE: Place the GLAND COVER onto the TRIM NUT making sure it is fully seated and place the HANDLE onto the GLAND COVER in the desired orientation then thread and securely tighten the. PAGE 10 OF 11 UPDATED ON 8.23.2018

* TURN ON WATER AND CHECK ALL CONNECTIONS FOR LEAKS! A RUBBER WASHER for the is provided. If desired, a bead of caulk or a clear silicone may be applied where the contacts the finished wall. [1/2" MALE THREAD] [CHECK FOR LEAKS] (x2) RUBBER WASHER PIVOT JOINT FLOW REGULATOR SHOWERHEAD [CHECK FOR LEAKS] 21. Insert the RUBBER WASHER into the PIVOT JOINT on the SHOWER HEAD (packaged separately) then thread and securely tighten the PIVOT JOINT onto the SHOWER ARM. NOTE: A FLOW REGULATOR is located in the PIVOT JOINT. 22. Turn on the water and operate the SHOWER HEAD to ensure it pivots and functions properly. OPTIONAL: Operate the DIVERTER VALVE HANDLE to ensure it diverts and functions properly. Inspect all connections for leaks then turn the water off. 23. Slide the S on the INLET ELBOWS against the finished wall. PAGE 11 OF 11 UPDATED ON 8.23.2018