3DLevelScanner. Technical Data Sheet. Level Sensor. Non-Contact, Multiple-Point Measurement

Similar documents
3DLevelScanner. Technical Data Sheet. Level Sensor. Non-Contact, Multiple-Point Measurement

OEM radar transmitter, for aggressive media level measurement

Level Measurement Continuous level measurement Radar transmitters

Level Measurement. Continuous level measurement Radar transmitters SITRANS LR460. 4/258 Siemens FI

Level Measurement Continuous level measurement Radar transmitters

Ultrasonic level measuring device, non-contact

Process display RIA 261

6GHz Intelligent Radar Level Meter Product Manual. Model:KRD520 SERIES

SITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview

Coriolis Massflowmeter

Accutech BR10. Wireless base radio

TEK-TEMP 2100A. Explosion-Proof Temperature Transmitter. TEMPERATURE. Technology Solutions

OPTIWAVE 1010 Technical Datasheet

GENERAL PURPOSE INDICATOR LOOP POWERED WITH VERY LARGE DIGITS DATASHEET F090 - GENERAL PURPOSE INDICATOR

Rod probe With coaxial tube reference probe

DOC. NO. : C3200-E04A APPROVED. Smart PressureTransmitter for Gauge and Absolute Pressure Measurement MODEL APT3200

Field indicator for current loops with HART communication Models DIH50, DIH52

Level Measurement. Continuous level measurement - Radar transmitters SITRANS LR400 5/229. Overview

Level Measurement. Continuous level measurement - Radar transmitters SITRANS LR400 5/229. Overview

Mobrey Ultrasonic. MSP422, MSP400RH, and MSP900GH Level Transmitters. Product Data Sheet February 2015 IP2045, Rev EA

SILVER SERIES. Reliable compact industrial infrared thermometers for. Temperatures below 3632 F/2000 C Non-reflective target materials Moving targets

Accutech DP20. Wireless differential pressure field unit

RHE11. Hazardous Area Multifunction Coriolis Flow Transmitter. Features. Applications. Benefits

SITRANS F flowmeters SITRANS F US. Transmitter FUS060. Overview

ICARUS ELECTRONIC GAS VOLUME CONVERTER

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted

Coriolis Massflowmeter

Radar Level Measurement micropilot FMR 130 for stilling wells

Installation instructions Dec. 2002

VITO LT. Global Experience. Locally Applied. A dependable choice.

SALES SERVICE +358 (0)

Installation guide 971 SmartRadar LTi

Submersible pressure sensor For oils and fuels Model LF-1

PNEUMATIC, ELECTRO-PNEUMATIC & SMART DIGITAL.

The Radar Level Meters can be installed both in metallic or non metallic tanks; their use is not harmful to humans or environment.

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

Technical Information Nivector FTC968, FTC968Z

0 2 1 â Ó. itemp HART TMT182. Technical Information

Rosemount 3101, 3102, and 3105

Manufactured by M-Sens 2 Online-Moisture Meter for Solids. Moisture % Product Information.

Process transmitter Model UPT-20, with pressure port Model UPT-21, with flush diaphragm

Sarasota CM200 Sarasota HME900 Density Converter Electronics

Wireless Acoustic Transmitters Series XYR 5000, Model WN571 Specifications - Americas

Positioner with HART Communication Type 3780

Level instruments. Continuous level measurement - Radar transmitters SITRANS LR300. 5/180 Siemens FI Overview

Accutech GP10. Wireless gauge pressure field unit

Field indicator for current loops with HART communication Models DIH50, DIH52

Fisher 646 Electro-Pneumatic Transducers

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 1.5 s adjustable. 20 ms. 60 ms. 60 ms. Approx. 1.

Servo Gauge 854 XTG. Global Experience. Locally Applied. Cut costs, not repeatability.

Intrinsically Safe Pressure Transmitter for highest pressure applications in hazardous environments Model IS-20-H

Pressure measurement. Process pressure/hydrostatic VEGAWELL 72. Product Information

600T Series Transmitters Model 653L Electronic temperature transmitter (PC programmable for RTD and resistance) Specification Sheet

Accutech AP10. Wireless absolute pressure field unit

Accutech AM20. Wireless acoustic monitor field unit

PROGRAMMABLE FIELD TEMPERATURE TRANSMITTER

Submersible pressure sensor For water and wastewater Model LW-1

600T Series Transmitters. Specification Sheet. Model 653T Electronic temperature transmitter (PC programmable)

Submersible pressure sensor For superior applications Model LF-1

prosonic T FMU230, FMU231

FOSTEN AUTOMATION SÉRIE F500-RD

Resistance thermometer Model TR30, compact design

process measurement solutions Mobrey MSP IP wire 24V loop powered ultrasonic level transmitters

Temperature Input Module for Zone 1 Series 9482/32

Coriolis Mass Flow Meter Model TM

Installation guide 873 SmartRadar Control Unit & Antenna Unit

Analog Universal Module HART for Zone 2 Series 9468/33

Serie NW - Acoustic Wave. Option list. Applications / Overview

Wireless Dual Discrete Input Transmitter Series XYR 5000, Model WW59x Specifications - Americas

Ultrasonic Liquid Level Transmitters

DATASHEET F090 - GENERAL PURPOSE INDICATOR

Intrinsically Safe Pressure Transmitter for applications in hazardous environments and shipbuilding industry Model IS-20-S, IS-21-S, IS-20-F, IS-21-F

ABB MEASUREMENT & ANALYTICS. LLT100, LM80 and LM200 Lasers for level now everything is possible

Level measurement Radar

MICROCOR ER WIRELESS TRANSMITTER

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 20 ms. 60 ms. 60 ms. Approx. 1.3 kg. Approx. 0.9 kg. Approx. 5.

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

DREXELBROOK. IMPULSE Series. Guided Wave Radar (TDR) Easy to install, Easy to use. Dependable performance. The New Impulse Guided Wave Radar

Incremental encoders Blind hollow shaft or cone shaft pulses per revolution

DREXELBROOK. IMPULSE Series Guided Wave Radar (TDR) for Total Level and Volumetric Measurements. Easy to install, Easy to use. Dependable performance

PRODUCT SPECIFICATION AND MODEL SELECTION GUIDE

0 2 1 â Ó. itemp HART TMT182. Technical Information

Pressure measurement. Process pressure/hydrostatic VEGAWELL 52. Product Information

AccuSolar SOLAR POWERED SYSTEM

TIDALFLUX 2300 F Technical Datasheet

Operating Instructions

MULTI-DROPS DIGITAL MODEM FOR PRIVATE LINE

Rosemount 848L Logic Transmitter with FOUNDATION Fieldbus

Electro-Magnetic Flowmeters COPA-XE

Mass and Volume Flow Transmitter

ED701 General Industry Pressure Transmitter

Analog Input Module HART Ex i / I.S. Inputs, Channels Type 9461/

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

Ultrasonic transducers being installed in the 2.4m (96 ) aqueduct at Watchgate WTW, Cumbria, UK.

LST100 Ultrasonic level transmitter for upstream oil and gas

Nivotester FTR325. Technical Information. 1-channel switch amplifier for the microwave barrier Soliwave FDR50/FQR50

ENRAF SERVO GAUGE 854 ATG Setting the standard in gauging.

Level detection in liquid. Conductive. VEGAKON 61 VEGAKON 66 Probes EL 1, 3, 4, 6, 8. Product Information

Pressure transmitter for general industrial applications Model A-10

Smart Pressure Transmitter

Transcription:

Technical Data Sheet Distribué par : Contact : hvssystem@hvssystem.com Tél : 0326824929 Fax : 0326851908 Non-Contact, Multiple-Point Measurement The 3DLevelScanner is a noncontact, dust-penetrating bin measurement device that detects irregular surfaces in powder or solid materials and then calculates highly accurate bin volume estimates. Siège social : 2 rue René Laennec 51500 Taissy France www.hvssystem.com 3DLevelScanner Level Sensor Featuring APM Automation Solutions Ltd Technology (patent pending) www.binmaster.com

Overview Accurate Volume Measurement The BinMaster 3DLevelScanner uses non-contact, dust-penetrating technology to provide unsurpassed bin volume accuracy. Unlike conventional single point devices, it works by measuring multiple points within the bin. The 3DLevelScanner uses a very low frequency acoustical signal to penetrate dust and take measurements which are determined by how long the signal takes to travel to solid or powder material and return to the device. This technology is proven to perform in powders and bulk solids, determining a highly accurate volume of materials contained in tanks, silos, and warehouses. Display Easy navigation LCD with 4-button operation Key Specifications Preferred Applications Powders and Solids Measuring Range 200 feet (61 meters) Process Fitting Thread, Flange, Mounting Strap Process Temperatures -40 to +185 F (-40 to +85 C) Process Pressure -0.2 1 bar (-2.9 to 14.5 psi) Signal Output 4-wire 4-20 ma/hart/rs-485/modbus Emitting Frequency 3 KHz to 10 KHz Same housing for all versions 4-wire 4-20 ma/hart/ RS-485/Modus

Technical Data Materials, Non-Wetted Parts Housing Painted aluminum die casting Inspection Window in Housing Cover Polycarbonate Antenna Painted aluminum die casting Flange Steel Weight 12.3 lb (5.6 kg) Thread version Output Variable Output Signal 4-20 ma/hart, RS-485, Modbus RTU, TCP/IP Resolution 10 µa Fault Signal Current output unchanged, 22 ma > 3.6 ma (adjustable) Current Limitation 22 ma Load 4-wire sensor Max. 500 Ohm Ambient Conditions Ambient, storage and transport temperature -40 to +185 F (-40 to 85 C) Relative humidity 20% to 85% Altitude 16,400 ft (5,000 m) Process Conditions Vessel Pressure -0.2 to 1 bar (-2.9 to 14.5 psi or -20 to 100 kpa) Process Temperature Measured on the Process Fitting -40 to +185 F (-40 to +85 C) Vibration Resistance Mechanical vibrations with 2 g and 5 to 200 Hz Electromechanical Data Cable Entry/Plug 1 x cable entry M20x1.5 (cable-ø 8 to 12mm) 1 x blind stopper M20x1.5 OR 2 x cable entry 1/2 NPT Display Panel LCD 4 lines x 20 characters Adjustment Elements 4 keys Protection IP67

Technical Data Power supply 4-wire instrument (Active) 4-20 ma / HART Supply Voltage 20 to 32 VDC Power Consumption Max 4VA; max 3 W Electrical Protective Measures Protection IP67 according to IEC 60529 Approvals ATEX ATEX II 1/2D, 2D, Ex ibd/iad 20/21 T110 C ATEX II 2G Ex ia/ib IIB T4 FM FM Intrinsically Safe Class I, II, Division I, Groups C, D, E, F, G (CFM pending) IECEx IEC EEx ia IIC T6 (pending) CE EMC Emission EN 61326:1997 (Class B) Susceptibility IEC / EN 61326:1997 + A1:1998 + A2:2001 + A3:2003 NSR (73/23/EWG) EN 61010-1:2001 FCC Conformity To part 15 of the FCC regulations FCC 47 CFR part 15:2007, subpart B, class A Measurement Characteristics Frequency 3 to 10 khz Beam angle 30 to 70 degrees

Dimensions 3DLevelScanner II with horn antenna in flange version 3DLevelScanner II with horn antenna in threaded version 161.1 (6.34") 142.5 (5.61") 161.1 (6.34") 142.5 (5.61") 576.8 (22.71") 290.4 (11.43") 6 (0.24") 1.93"-8UN Hole 52 (2.05") 286.5 (11.28") 576.8 (22.71") 290.4 (11.43") 1.93"-8UN Hole 52 (2.05") 286.5 (11.28") 193.3 (7.61") 193.3 (7.61") 3DLevelScanner II Housing 161.1 (6.34") 142.5 (5.61") 221.2 (8.71") 125 41 (1.61") Dimensions in mm (inches)

Electrical Connection & Wiring General Requirements The power supply range can differ depending on the instrument version. See the Technical Data section for full details. In hazardous areas, take note of the appropriate regulations, conformity and type of approval certificates of the sensors and power supply units. Power Supply 4-20 ma/hart 4-wire Power supply and signal current are carried on two separate connection cables. The output signal is active. Hence, the PLC must be configured passive. Connection Cable An outer cable diameter of 0.31-0.47 (8-12 mm) ensures the seal effect of the cable entry. If electromagnetic interference is expected, the use of screened cable for the signal lines is recommended. Wiring Plans Display PS 4 to 20 ma/hart PS RS-485 4 to 20 ma

Operation The 3DLevelScanner can be set up and operated using one of the following: The LCD panel HART handheld A software tool (3DLevel Manager) Adjustment Using the LCD Panel Navigate to the left within a function group; press ESC for 3 sec to go back to the basic screen Navigate upwards in the selection list; edit numeric value within a function Navigate downwards in the selection list; shifts to the right within a function Navigate to the right within a function group; confirmation and and Increase contrast settings of the LCD Decrease contrast settings of the LCD and and Hardware lock/unlock After a hardware lock, operation of the instrument via display or remote communication is not possible. The hardware can only be unlocked via the display, and an unlock parameter must be entered to do so. The display continues uninterrupted. When all three buttons are pressed the display writes: Hardware locked. When all three buttons are pressed again the display asks for unlock parameter. Adjustment using the 3DLevel Manager Software Tool The 3DLevelScanner can be configured and operated via a software tool (3DLevel Manager). Connect the 3DLevelScanner according to according to the following diagram. 1. RS-232 USB connection 2. 3DLevelScanner 3. HART adapter cable 4. HART Resistance -250 Ohm 3DLevel Manager Software

3DLevelScanner 3DLevelScanner Model Description Part No. 3DLS-SB 3DLS-S 3DLS-M 3DLS-MV 3DLevelScanner-SB, 20-36 VDC, 4 to 20 ma output/hart protocol, and RS-485 communications. Determines the average volume of stored materials based on a 30 beam angle in silos up to 14' diameter and 40' tall. Unit comes with internal LCD display and 3DLevel Manager software is included with every unit supplied. Hazardous location approved, FM Listed for Class I, II, Division 1, Groups C, D, E, F & G. One year warranty. 3DLevelScanner-S, 20-36 VDC, 4 to 20 ma output/hart protocol, and RS-485 communications. Determines the average volume of stored materials based on a 30 beam angle in silos up to 14' diameter and 200' tall. Unit comes with internal LCD display and 3DLevel Manager Software is included with every unit supplied. Hazardous location approved, FM Listed for Class I, II, Division 1, Groups C, D, E, F & G. One year warranty. 3DLevelScanner-M, 20-36 VDC, 4 to 20 ma output/hart protocol, and RS-485 communications. Accurate readings of level and volume of stored materials based on a 70 beam angle. Wider beam angle is appropriate for silos up to 45' in diameter and 200' tall, and where improved accuracy in smaller silos is required. Unit comes with internal LCD display and 3DLevel Manager Software is included with every unit supplied. Hazardous location approved, FM Listed for Class I, II, Division 1, Groups C, D, E, F & G. One year warranty. 3DLevelScanner-MV, 20-36 VDC, 4 to 20 ma output/hart protocol, and RS-485 communications. Accurate readings of level and volume of stored materials based on a 70 beam angle. Wider beam angle is appropriate for silos up to 45' in diameter and 220' tall, and where improved accuracy in smaller silos is required. Identical to the Model 3DLS-M, with the addition of a special tool that allows 3D graphical representation of the stored contents for display on a remote computer screen. Unit comes with internal LCD display and 3DLevel Manager Software is included with every unit supplied. Hazardous location approved, FM Listed for Class I, II, Division 1, Groups C, D, E, F & G. One year warranty. 730-0578 730-0559 730-0560 730-0561 Note: Models 3DLS-S, 3DLS-M, and 3DLS-MV can be used on silos with a larger diameter than specified, but with decreased accuracies given that the beam angle will not span the entire surface of the material. For a very accurate reading of volume and 3D profiling, it is necessary to stay within the specified diameter and silo heights. 3DLinkPro Model Description Part No. 3DLP-R-GSM BinMaster Remote 3DLinkPro with GPRS Cellular Modem. 730-0562 Contact BinMaster for mounting plates, wireless transceiver and other accessories. Distribué par : 2 rue René Laennec 51500 Taissy France Fax: 03 26 85 19 08, Tel : 03 26 82 49 29 Email : hvssystem@hvssystem.com Site web : www.hvssystem.com Shipping Address: 7201 N. 98th St. Lincoln, NE 68507 Mailing Address: P.O. Box 29709 Lincoln, NE 68529 800.278.4241 402.434.9102 Fax: 402.434.9133 www.binmaster.com info@binmaster.com Featuring APM Automation Solutions Ltd Technology (patent pending) 05-10-2M-NPC ISO 9001 Certified 2010 BinMaster. All Rights Reserved.