Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800)

Similar documents
TRIO-PS/1AC/24DC/ 5. Extract from the online catalog. Order No.:

MINI-PS AC/2X15DC/1

UNO-PS/1AC/24DC/150W. Primary-switched power supply unit. Data sheet. 1 Description

PHOENIX CONTACT - 05/2008. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area.

PHOENIX CONTACT - 06/2008. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

QUINT-PS/ 1AC/24DC/20

QUINT-PS AC/24DC/40

MINI-PS AC/24DC/1.3

Switching power supplies CP range, Linear power supplies CP-L range. Content

QUINT-PS/ 3AC/24DC/10

Type CP-S, CP-C & CP-A Switch mode

QUINT-PS-24DC/24DC/10

QUINT-PS/ 3AC/24DC/40

CP-T range Product group picture

CP-T range Benefits and advantages

Power supply CP-E 24/2.5

For Immediate Delivery call KMParts.com at (866)

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 320VAC 360VAC 400VAC 400VAC

Power supply CP-E 24/20.0

QUINT-PS/1AC/24DC/10. Power supply unit. Data sheet. 1 Description

Power supply CP-E 48/5.0 Primary switch mode power supply Data sheet

Power supply CP-T 48/20.0 Primary switch mode power supply

Power supply CP-T 24/20.0 Primary switch mode power supply

Power supply CP-T 48/5.0 Primary switch mode power supply

Power supply CP-E 12/10.0 Primary switch mode power supply Data sheet

Power supply CP-T 24/10.0 Primary switch mode power supply

Power supply CP-T 24/40.0 Primary switch mode power supply

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 400VAC

Power supply CP-E 24/0.75

Power supply CP-E 24/2.5

TRIO-PS-2G/1AC/24DC/5

Power supply CP-D 24/4.2 Primary switch mode power supply

CP-E range Benefits and advantages

TSX Series. Modicon Manuals. Presented by: Modicon PLC. Schneider Electric Quantum Modicon Gould Gettys

Power supply CP-D 24/1.3

10/2 Product overview. 10/3 4AC3 0, 4AC3 1 bell transformers. 10/5 4AC AC3 6 transformers for permanent loads. 10/8 4AC2 4 power supply units

Power supply CP-D 12/2.1

Advantages. Applications

Data sheet Functional Electronics PRO-M. Power supplies for space-saving use in automation technology

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

AC/DC Power Supply Single-Output

Primary switch mode power supplies Product group picture

Output Voltage nom. (adjustable)

LCL Series. SIngle Output Industrial Supplies. High Efficiency. Low Cost. 150 W Convection Cooled. 300 W & 500 W with Internal Fans

Single or parallel use selectable by user Adjustable output voltage. New narrow width saves panel space

RISH Ducer TV 808, 2 channels Isolating amplifier unipolar / bipolar

Control module CP-A CM

EMD-FL-3V-400. Electronic monitoring relay for voltage monitoring in three-phase networks. INTERFACE Data sheet _en_03. 1 Description.

General technical data. Pollution degree 2. EMC / shock / vibration Noise emission acc. to EN Electrical safety (applied standards)

TMT Series, 10 to 50 Watt. Order Code Output Power Output 1 PCB-Mount Chassis Mount max.

Isolators A3/1. Vibration Transducer Supply Unit Series

ProLine P Precise Temperature Measurement at High Voltage Potentials up to 6.6 kv

* Short-circuit detection at On pushbutton. Applications. Indication. S M6801_a S11 A3 S12 S21 S23 S22 S (+)

Theta 60R. Technical Data Sheet. Special Features. Fig. 2 Theta R, 2 channel version, in housing S17 hole mounting brackets pulled out.

3 Ex i Isolators. Switching Repeater with Power Relay (250 V / 4 A) Type 9170/ Type 9170/

PSR-SCP- 24DC/ESD/5X1/1X2/300

Theta 20A / 20V. Technical Data Sheet. Special Features

Datasheet. PRO-M Series Power Supplies

Transformers, Power Supply Units and Socket Outlets

LED Driver Linear / area fixed output

ATS01N112FT soft starter for asynchronous motor - ATS01-12 A V KW

ATS01N125FT soft starter for asynchronous motor - ATS01-25 A V KW

PHASED OUT. LED Driver Linear / area fixed output. Driver LCI 35W 350mA 900mA TOP lp TOP series

PHASED OUT. LED Driver Linear / area fixed output. Driver LCI 20W 150mA 400mA TOP lp TOP series. Product description

Output Voltage nom. (adjustable)

Power Supplies 3. SDN-C Compact DIN Rail Series

TPP 40 Series, 40 Watt. Order code Output voltage Output current max. Efficiency. max. screw terminal pin connector Vout 1 Vout 2 Vout 3

ADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W

Industrial Power Supplies

DSA150 Series. xxx Series. 150 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125.

Related Products SDP Series SFL Series SCP Series SCL Series SDU UPS

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series

Output Voltage* (nom.)(adjustable)

SIPROTEC easy 7SJ46 Numerical Overcurrent Protection Relay

Theta Hz. Technical Data Sheet. Special Features

Binary Output Series 9175

STEP-UPS/24DC/24DC/3. Uninterruptible power supply. Data sheet. 1 Description. Features

06528E00. ATEX / IECEx NEC 505 NEC 506 NEC 500

LDC480 Series is a single phase, extremely compact Power Supply with active PFC specially designed for space sensitive and demanding applications.

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160 Rev. F

LED Driver Linear / area fixed output

MODEL MCHQ250V12B MCHQ250V24B MCHQ250V54B

IB IL 24 PWR IN/PS IB IL 24 PWR IN/PS-PAC

Switched mode power supply for DIN rail mounting type SMP23 DC24V/40A

Switched mode power supply for DIN rail mounting type SMP21 DC24V/10A

LED Driver Compact fixed output

Transmitter for temperature and direct current variables in four-wire circuit. Contrans T TEU 315, TEU 315-Ex, TEU 325, TEU 325-Ex 11-3.

The DO8332 module is equipped with eight outputs for 1-wire connections. The rated output current is 2 A.

MCR-VAC-UI-0-DC. Voltage transducer for AC voltages. INTERFACE Data sheet _en_02. 1 Description

PHASED OUT. LED Driver Compact fixed output. Driver LCI 20W 350mA 900mA TOP C TOP series

LED Driver Compact fixed output

SINEAX TV 808, 2 channels Isolating Amplifier Unipolar/Bipolar

PHASED OUT. LED Driver Compact fixed output. Driver LCI 10W 150mA 400mA TOP C TOP series. Product description

ATS01N103FT soft starter for asynchronous motor - ATS01-3 A V KW

PHASED OUT. LED Driver Compact fixed output. Driver LCI 10W 350mA 900mA TOP C TOP series

6ES7214-1AG31-0XB0. General information Engineering with. Supply voltage 24 V DC Yes permissible range, upper limit (DC)

Features. Regulated Converter. RAC05-K 5 Watt 1 x 1. Single Output RAC05- SK. AC/DC Converter

Output of three-phase motors at 50 Hz and 400 V

Type: EASY719 DA RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 12 V DC. Description

Transcription:

Primary switched-mode power supply units In standard machine production, the requirements for a power supply unit are mostly specified in advance. Here, the TRIO POWER power supply units are suitable which provide basic functions at a very high level. 1~ High operational reliability of onephase devices due to the high dielectric strength of up to 300 VAC. TRIP POWER has the following advantages: High operational reliability due to the high MTBF (Mean Time Between Failure) more than 500,000 h. Rugged design with metal housing and temperature wide range of -25 to +70 C. Compensation of voltage drops through output voltage that can be set on the front side. Minimizing the installation costs A third negative terminal is available for the secondary-side grounding. An additional potential distributor or double assignment of a terminal block is not required. This saves time and subsequently costs for the secondary-side grounding. Description Order o. Power supply unit, primary switched-mode Width 32 mm TRIO-PS/1AC/24DC/ 2.5 2866268 1 Technical data Input data Input nominal voltage range 100 V AC... 240 V AC Input voltage range AC/DC 85 V AC... 264 V AC Frequency range 45 Hz... 65 Hz Current consumption (nominal load) 0.95 A (120 V AC) / 0.5 A (230 V AC) Inrush current limitation at 25 C (typ.) / I 2 t < 15 A / 0.5 A 2 s Mains buffering (I, typ.) > 20 ms (120 V AC) / > 100 ms (230 V AC) Input fuse 2 A (slow-blow, internal) Recommended backup fuse, S switch 6 A, 10 A, 16 A (characteristic B) Output data ominal output voltage 24 V DC ±1% Setting range of the output voltage 22.5 V DC... 29.5 V DC (> 24 V constant capacity) Output current 2.5 A Can be connected in parallel / series Yes / o Max. power dissipation (idling/nominal load) 0.8 W / 10 W Efficiency (typ.) > 86% (at 230 V AC and nominal values) Residual ripple < 30 mv PP Signaling Signaling DC OK ED General data Weight / Dimensions W x H x D 0.5 kg / 32 x 130 x 115 mm Installation position Horizontal DI rail S 35, E 60715 Distance during assembly Can be aligned: Horizontal 0 cm, vertical 5 cm of connection Screw connection Degree of protection / Class of protection IP20 / I, with connection MTBF (at nominal load, 40 C) > 500 000 h in acc. with IEC 61709 (S 29500) Ambient temperature (operation) -25 C... 70 C (> 55 C derating) Ambient temperature (storage/transport) -40 C... 85 C Max. permissible relative humidity (operation) 95% (at 25 C, no condensation) Standards/regulations Insulation voltage input/output 2 kv AC (routine test) / 4 kv AC (type test) Electromagnetic compatibility Electrical safety, safety transformer E 60950/VDE 0805 (SEV), E 61558-2-17 Electronic equipm. for electrical power installations E 50178/VDE 0160 (V) Safe isolation DI VDE 0100-410, DI VDE 0106-1010 U approvals U/C-U listed U 508, U/C-U Recognized U 60950 imitation of harmonic line currents E 61000-3-2 TRIO 24 V DC/2.5 A U u F 570 PHOEIX COTACT

TRIO 24 V DC/5 A Order o. TRIO 24 V DC/10 A Order o. Order o. TRIO-PS/1AC/24DC/ 5 2866310 1 TRIO-PS/1AC/24DC/10 2866323 1 TRIO-PS/1AC/24DC/20 2866381 1 100 V AC... 240 V AC 100 V AC... 240 V AC 100 V AC... 240 V AC 85 V AC... 264 V AC 85 V AC... 264 V AC 85 V AC... 264 V AC 45 Hz... 65 Hz 45 Hz... 65 Hz 45 Hz... 65 Hz 1.65 A (120 V AC) / 0.9 A (230 V AC) 2.5 A (120 V AC) / 1.3 A (230 V AC) 4.6 A (120 V AC) / 2.4 A (230 V AC) < 15 A / 1.1 A 2 s < 15 A / 0.7 A 2 s < 15 A / 1.4 A 2 s > 20 ms (120 V AC) / > 110 ms (230 V AC) > 24 ms (120 V AC) / > 24 ms (230 V AC) > 13 ms (120 V AC) / > 13 ms (230 V AC) 3.15 A (slow-blow, internal) 6.3 A (slow-blow, internal) 10 A (slow-blow, internal) 6 A, 10 A, 16 A (characteristic B) 10 A, 16 A (characteristic B) 16 A (characteristic B) 24 V DC ±1% 24 V DC ±1% 24 V DC ±1% 22.5 V DC... 29.5 V DC (> 24 V constant capacity) 22.5 V DC... 29.5 V DC (> 24 V constant capacity) 22.5 V DC... 29.5 V DC (> 24 V constant capacity) 5 A 10 A 20 A Yes / o Yes / o Yes / o 1.1 W / 18 W 6.7 W / 30 W 4 W / 46 W > 89% (at 230 V AC and nominal values) > 89% (at 230 V AC and nominal values) > 91% (at 230 V AC and nominal values) < 20 mv PP < 10 mv PP < 10 mv PP ED ED ED 0.6 kg / 40 x 130 x 115 mm 1.4 kg / 60 x 130 x 152.5 mm 2.2 kg / 115 x 130 x 152.5 mm Horizontal DI rail S 35, E 60715 Horizontal DI rail S 35, E 60715 Horizontal DI rail S 35, E 60715 Can be aligned: Horizontal 0 cm, vertical 5 cm Can be aligned: Horizontal 0 cm, vertical 5 cm Can be aligned: Horizontal 0 cm, vertical 5 cm Screw connection Screw connection Screw connection IP20 / I, with connection IP20 / I, with connection IP20 / I, with connection > 500 000 h in acc. with IEC 61709 (S 29500) > 500 000 h in acc. with IEC 61709 (S 29500) > 500 000 h in acc. with IEC 61709 (S 29500) -25 C... 70 C (> 55 C derating) -25 C... 70 C (> 55 C derating) -25 C... 70 C (> 55 C derating) -40 C... 85 C -25 C... 85 C -40 C... 85 C 95% (at 25 C, no condensation) 95% (at 25 C, no condensation) 95% (at 25 C, no condensation) 2 kv AC (routine test) / 4 kv AC (type test) 2 kv AC (routine test) / 4 kv AC (type test) 2 kv AC (routine test) / 4 kv AC (type test) E 60950/VDE 0805 (SEV), E 61558-2-17 E 60950/VDE 0805 (SEV), E 61558-2-17 E 60950/VDE 0805 (SEV), E 61558-2-17 E 50178/VDE 0160 (V) E 50178/VDE 0160 (V) E 50178/VDE 0160 (V) DI VDE 0100-410, DI VDE 0106-1010 DI VDE 0100-410, DI VDE 0106-1010 DI VDE 0100-410, DI VDE 0106-1010 U/C-U listed U 508, U/C-U Recognized U 60950 U/C-U listed U 508, U/C-U Recognized U 60950 U/C-U listed U 508, U/C-U Recognized U 60950 E 61000-3-2 E 61000-3-2 E 61000-3-2 TRIO 24 V DC/20 A Width 40 mm U u F Width 60 mm U u Width 115 mm U u Output 0.5-6 0.5-4 20-10 M3 PHOEIX COTACT 571

Primary switched-mode power supply units 3~ High system availability of all 3-phase devices, even if one phase fails permanently: If the input of the current supply is provided with only two phases, TRIO POWER power supply units provide the entire output power permanently. Here, the 5 A and 10 A devices are suitable for constant operation in two phases without modifying the technical data devices of the power supply unit. Power supply unit, primary switched-mode Width 40 mm 1 2 (3) Order o. TRIO-PS/3AC/24DC/ 5 2866462 1 Technical data Input data Input nominal voltage range 2x / 3x 400 V AC... 500 V AC Input voltage range AC/DC 320 V AC... 575 V AC Frequency range 45 Hz... 65 Hz Current consumption (nominal load) Approx. 3x 0.3 A (400 V AC) / Approx. 3x 0.3 A (500 V AC) Inrush current limitation at 25 C (typ.) / I 2 t < 15 A / 0.2 A 2 s Mains buffering (I, typ.) > 20 ms (400 V AC) / > 30 ms (480 V AC) Input fuse - Recommended backup fuse, S switch 3x 6 A, 3x 10 A, 3x 16 A (characteristic B) Output data ominal output voltage 24 V DC ±1% Setting range of the output voltage 22.5 V DC... 29.5 V DC (> 24 V constant capacity) Output current 5 A Can be connected in parallel / series Yes / o Max. power dissipation (idling/nominal load) 4 W / 15 W Efficiency (typ.) > 89% (at 400 V AC and nominal values) Residual ripple < 30 mv PP Signaling Signaling DC OK ED General data Weight / Dimensions W x H x D 0.6 kg / 40 x 130 x 115 mm Installation position Horizontal DI rail S 35, E 60715 Distance during assembly Can be aligned: Horizontal 0 cm, vertical 5 cm of connection Screw connection Degree of protection / Class of protection IP20 / I, with connection MTBF (at nominal load, 40 C) > 500 000 h in acc. with IEC 61709 (S 29500) Ambient temperature (operation) -25 C... 70 C (> 55 C derating) Ambient temperature (storage/transport) -40 C... 85 C Max. permissible relative humidity (operation) 95% (at 25 C, no condensation) Standards/regulations Insulation voltage input/output 2 kv AC (routine test) / 4 kv AC (type test) Electromagnetic compatibility Electrical safety, safety transformer E 60950/VDE 0805 (SEV), E 61558-2-17 Electronic equipm. for electrical power installations E 50178/VDE 0160 (V) Safe isolation DI VDE 0100-410, DI VDE 0106-1010 U approvals U/C-U listed U 508, U/C-U Recognized U 60950 imitation of harmonic line currents E 61000-3-2 TRIO 24 V DC/5 A u Output 0.2-2.5 0.2-2.5 16-12 M2,5 572 PHOEIX COTACT

1 2 (3) TRIO 24 V DC/10 A Output 0.2-2.5 0.2-2.5 16-12 M2,5 Order o. 1 2 3 TRIO 24 V DC/20 A Output 0.5-6 0.5-4 12-10 M3 Order o. 1 2 3 Order o. TRIO-PS/3AC/24DC/10 2866459 1 TRIO-PS/3AC/24DC/20 2866394 1 TRIO-PS/3AC/24DC/40 2866404 1 2x / 3x 400 V AC... 500 V AC 3x 400 V AC... 500 V AC 3x 400 V AC... 500 V AC 320 V AC... 575 V AC 320 V AC... 575 V AC 320 V AC... 575 V AC 45 Hz... 65 Hz 45 Hz... 65 Hz 45 Hz... 65 Hz Approx. 3x 0.6 A (400 V AC) / 3x 0.5 A (480 V AC) Approx. 3x 1.1 A (400 V AC) / 3x 0.8 A (480 V AC) Approx. 3x 2 A (400 V AC) / 3x 1.6 A (480 V AC) < 15 A / 0.2 A 2 s < 15 A / 0.5 A 2 s < 20 A / 1.3 A 2 s > 20 ms (400 V AC) / > 25 ms (480 V AC) > 17 ms (400 V AC) / > 20 ms (480 V AC) > 16 ms (400 V AC) / > 20 ms (480 V AC) - - - 3x 6 A, 3x 10 A, 3x 16 A (characteristic B) 3x 6 A, 3x 10 A, 3x 16 A (characteristic B) 3x 10 A, 3x 16 A (characteristic B) 24 V DC ±1% 24 V DC ±1% 24 V DC ±1% 22.5 V DC... 29.5 V DC (> 24 V constant capacity) 22.5 V DC... 29.5 V DC (> 24 V constant capacity) 22.5 V DC... 29.5 V DC (> 24 V constant capacity) 10 A 20 A 40 A Yes / o Yes / o Yes / o 6 W / 28 W 6 W / 48 W 16 W / 91 W > 89% (at 400 V AC and nominal values) > 91% (at 400 V AC and nominal values) > 91.5% (at 400 V AC and nominal values) < 10 mv PP < 10 mv PP < 20 mv PP ED ED ED 1.3 kg / 60 x 130 x 152.5 mm 2 kg / 115 x 130 x 152.5 mm 2.9 kg / 139 x 130 x 190 mm Horizontal DI rail S 35, E 60715 Horizontal DI rail S 35, E 60715 Horizontal DI rail S 35, E 60715 Can be aligned: Horizontal 0 cm, vertical 5 cm Can be aligned: Horizontal 0 cm, vertical 5 cm Can be aligned: Horizontal 0 cm, vertical 5 cm Screw connection Screw connection Screw connection IP20 / I, with connection IP20 / I, with connection IP20 / I, with connection > 500 000 h in acc. with IEC 61709 (S 29500) > 500 000 h in acc. with IEC 61709 (S 29500) > 500 000 h in acc. with IEC 61709 (S 29500) -25 C... 70 C (> 55 C derating) -25 C... 70 C (> 55 C derating) -25 C... 70 C (> 55 C derating) -40 C... 85 C -40 C... 85 C -40 C... 85 C 95% (at 25 C, no condensation) 95% (at 25 C, no condensation) 95% (at 25 C, no condensation) 2 kv AC (routine test) / 4 kv AC (type test) 2 kv AC (routine test) / 4 kv AC (type test) 2 kv AC (routine test) / 4 kv AC (type test) E 60950/VDE 0805 (SEV), E 61558-2-17 E 60950/VDE 0805 (SEV), E 61558-2-17 E 60950/VDE 0805 (SEV), E 61558-2-17 E 50178/VDE 0160 (V) E 50178/VDE 0160 (V) E 50178/VDE 0160 (V) DI VDE 0100-410, DI VDE 0106-1010 DI VDE 0100-410, DI VDE 0106-1010 DI VDE 0100-410, DI VDE 0106-1010 U/C-U listed U 508, U/C-U Recognized U 60950 U/C-U listed U 508, U/C-U Recognized U 60950 U/C-U listed U 508, U/C-U Recognized U 60950 E 61000-3-2 E 61000-3-2 E 61000-3-2 TRIO 24 V DC/40 A Width 60 mm u Width 115 mm u Width 139 mm u Input 0.2-6 0.2-4 22-10 M3 Output 0.5-16 0.5-10 8-6 M4 PHOEIX COTACT 573

Primary switched-mode power supply units 1~, 12 V DC, 48 V DC With an adjustable output voltage of 12 V DC devices as well as the permanent current limitation, they are suitable for charging batteries for example. In the DC drives, long conductor paths lead to a voltage drop. 48 V devices providing high power at half the current as compared to 24 V devices are suitable here. TRIP POWER has the following advantages: High operational reliability due to the high MTBF (Mean Time Between Failure) more than 500,000 h. Rugged design with metal housing and temperature wide range of -25 to +70 C. Compensation of voltage drops through output voltage that can be set on the front side. Minimizing the installation costs A third negative terminal is available for the secondary-side grounding. An additional potential distributor or double assignment of a terminal block is not required. This saves time and subsequently costs for the secondary-side grounding. Description Order o. Power supply unit, primary switched-mode Width 32 mm TRIO-PS/1AC/12DC/ 5 2866475 1 Technical data Input data Input nominal voltage range 100 V AC... 240 V AC Input voltage range AC/DC 85 V AC... 264 V AC Frequency range 45 Hz... 65 Hz Current consumption (nominal load) Approx. 1 A (120 V AC) / Approx. 0.5 A (230 V AC) Inrush current limitation at 25 C (typ.) / I 2 t < 15 A / < 0.5 A 2 s Mains buffering (I, typ.) > 26 ms (120 V AC) / > 100 ms (230 V AC) Recommended backup fuse, S switch 6 A, 10 A, 16 A (characteristic B) Output data ominal output voltage 12 V DC ±1% Setting range of the output voltage 10 V DC... 18 V DC (> 12 V constant capacity) Output current 5 A Can be connected in parallel / series Yes / o Max. power dissipation (idling/nominal load) 0.9 W / 11 W Efficiency (typ.) > 83% (at 230 V AC and nominal values) Residual ripple < 20 mv PP Signaling Signaling DC OK ED General data Weight / Dimensions W x H x D 0.5 kg / 32 x 130 x 115 mm Installation position Horizontal DI rail S 35, E 60715 Distance during assembly Can be aligned: Horizontal 0 cm, vertical 5 cm of connection Screw connection Degree of protection / Class of protection IP20 / I, with connection MTBF (at nominal load, 40 C) > 500 000 h in acc. with IEC 61709 (S 29500) Ambient temperature (operation) -25 C... 70 C (> 55 C derating) Ambient temperature (storage/transport) -40 C... 85 C Max. permissible relative humidity (operation) 95% (at 25 C, no condensation) Standards/regulations Insulation voltage input/output 2 kv AC (routine test) / 4 kv AC (type test) Electromagnetic compatibility Electrical safety, safety transformer E 60950/VDE 0805 (SEV), E 61558-2-17 Electronic equipm. for electrical power installations E 50178/VDE 0160 (V) Safe isolation DI VDE 0100-410, DI VDE 0106-1010 U approvals U isted U 508, U/C-U Recognized U 60950 imitation of harmonic line currents E 61000-3-2 TRIO 12 V DC/5 A U u 574 PHOEIX COTACT

TRIO 12 V DC/10 A Order o. TRIO 48 V DC/5 A Order o. Order o. TRIO-PS/1AC/12DC/10 2866488 1 TRIO-PS/1AC/48DC/ 5 2866491 1 TRIO-PS/1AC/48DC/10 2866501 1 100 V AC... 240 V AC 100 V AC... 240 V AC 100 V AC... 240 V AC 85 V AC... 264 V AC 85 V AC... 264 V AC 85 V AC... 264 V AC 45 Hz... 65 Hz 45 Hz... 65 Hz 45 Hz... 65 Hz Approx. 1.7 A (120 V AC) / Approx. 0.9 A (230 V AC) Approx. 2.5 A (120 V AC) / Approx. 1.3 A (230 V AC) Approx. 4.6 A (120 V AC) / Approx. 2.4 A (230 V AC) < 15 A / < 1.1 A 2 s < 15 A / < 0.7 A 2 s < 15 A / < 1.4 A 2 s > 20 ms (120 V AC) / > 86 ms (230 V AC) > 15 ms (120 V AC) / > 16 ms (230 V AC) > 13 ms (120 V AC) / > 18 ms (230 V AC) 6 A, 10 A, 16 A (characteristic B) 10 A, 16 A (characteristic B) 16 A (characteristic B) 12 V DC ±1% 48 V DC ±1% 48 V DC ±1% 10 V DC... 18 V DC (> 12 V constant capacity) 30 V DC... 56 V DC (> 48 V constant capacity) 30 V DC... 56 V DC (> 48 V constant capacity) 10 A 5 A 10 A Yes / o Yes / o Yes / o 1.1 W / 18 W 7 W / 28 W 8 W / 49 W > 86% (at 230 V AC and nominal values) > 89% (at 230 V AC and nominal values) > 91% (at 230 V AC and nominal values) < 20 mv PP < 50 mv PP < 50 mv PP ED ED ED 0.6 kg / 40 x 130 x 115 mm 1.4 kg / 60 x 130 x 152.5 mm 1.9 kg / 115 x 130 x 152.5 mm Horizontal DI rail S 35, E 60715 Horizontal DI rail S 35, E 60715 Horizontal DI rail S 35, E 60715 Can be aligned: Horizontal 0 cm, vertical 5 cm Can be aligned: Horizontal 0 cm, vertical 5 cm Can be aligned: Horizontal 0 cm, vertical 5 cm Screw connection Screw connection Screw connection IP20 / I, with connection IP20 / I, with connection IP20 / I, with connection > 500 000 h in acc. with IEC 61709 (S 29500) > 500 000 h in acc. with IEC 61709 (S 29500) > 500 000 h in acc. with IEC 61709 (S 29500) -25 C... 70 C (> 55 C derating) -25 C... 70 C (> 55 C derating) -25 C... 70 C (> 55 C derating) -40 C... 85 C -40 C... 85 C -40 C... 85 C 95% (at 25 C, no condensation) 95% (at 25 C, no condensation) 95% (at 25 C, no condensation) 2 kv AC (routine test) / 4 kv AC (type test) 2 kv AC (routine test) / 4 kv AC (type test) 2 kv AC (routine test) / 4 kv AC (type test) E 60950/VDE 0805 (SEV), E 61558-2-17 E 60950/VDE 0805 (SEV), E 61558-2-17 E 60950/VDE 0805 (SEV), E 61558-2-17 E 50178/VDE 0160 (V) E 50178/VDE 0160 (V) E 50178/VDE 0160 (V) DI VDE 0100-410, DI VDE 0106-1010 DI VDE 0100-410, DI VDE 0106-1010 DI VDE 0100-410, DI VDE 0106-1010 U isted U 508, U/C-U Recognized U 60950 U isted U 508, U/C-U Recognized U 60950 U isted U 508, U/C-U Recognized U 60950 E 61000-3-2 E 61000-3-2 E 61000-3-2 TRIO 48 V DC/10 A Width 40 mm U u Width 60 mm U u Width 115 mm U u Output 0.5-0.6 0.5-4 20-10 M3 PHOEIX COTACT 575