INSTITUTE OF AERONAUTICAL ENGINEERING (Autonomous) Dundigal, Hyderabad ELECTRICAL AND ELECTRONICS ENGINEERING

INSTITUTE OF AERONAUTICAL ENGINEERING (Autonomous) Dundigal, Hyderabad

Code No: R Set No. 1

VALLIAMMAI ENGINEERING COLLEGE

INSTITUTE OF AERONAUTICAL ENGINEERING (Autonomous) Dundigal, Hyderabad

Hours / 100 Marks Seat No.

SHRI RAMSWAROOP MEMORIAL COLLEGE OF ENGG. & MANAGEMENT

148 Electric Machines

INSTITUTE OF AERONAUTICAL ENGINEERING (Autonomous) Dundigal, Hyderabad

INSTITUTE OF AERONAUTICAL ENGINEERING Dundigal, Hyderabad

INSTITUTE OF AERONAUTICAL ENGINEERING (AUTONOMOUS) Dundigal, Hyderabad

INSTITUTE OF AERONAUTICAL ENGINEERING (AUTONOMOUS)

PROBLEMS on Transformers

Aligarh College of Engineering & Technology (College Code: 109) Affiliated to UPTU, Approved by AICTE Electrical Engg.

86 chapter 2 Transformers

Code No: R Set No. 1

MAHARASHTRA STATE BOARD OF TECHNICAL EDUCATION

Downloaded From All JNTU World

Reg. No. : BASIC ELECTRICAL TECHNOLOGY (ELE 101)

3. What is hysteresis loss? Also mention a method to minimize the loss. (N-11, N-12)


MAHARASHTRA STATE BOARD OF TECHNICAL EDUCATION

TRANSFORMERS PART A. 2. What is the turns ratio and transformer ratio of transformer? Turns ratio = N2/ N1 Transformer = E2/E1 = I1/ I2 =K

Chapter 2-1 Transformers

Module 7. Transformer. Version 2 EE IIT, Kharagpur

ELECTRICAL TECHNOLOGY

Downloaded From JNTU World. B.Tech II Year II Semester (R09) Supplementary Examinations December/January 2014/2015 GENERATION OF ELECTRIC POWER

Module 1. Introduction. Version 2 EE IIT, Kharagpur

Electrical Machines I : Transformers

PART A. 1. List the types of DC Motors. Give any difference between them. BTL 1 Remembering

Transformer & Induction M/C

EEE3441 Electrical Machines Department of Electrical Engineering. Lecture. Basic Operating Principles of Transformers

UNIVERSITY OF TECHNOLOGY By: Fadhil A. Hasan ELECTRICAL MACHINES

CHAPTER 2. Transformers. Dr Gamal Sowilam

Hours / 100 Marks Seat No.

INSTITUTE OF AERONAUTICAL ENGINEERING

COLLEGE OF ENGINEERING DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING ACADEMIC YEAR / EVEN SEMESTER QUESTION BANK

ELECTRICAL ENGINEERING ESE TOPIC WISE OBJECTIVE SOLVED PAPER-II

SYNCHRONOUS MACHINES

1. (a) Determine the value of Resistance R and current in each branch when the total current taken by the curcuit in figure 1a is 6 Amps.

REV NO EXPERIMENT NO 1 AIM: To perform open and short circuit tests on 1-phase transformer and to calculate efficiency. Apparatus required:

CHIEF ENGINEER REG III/2 MARINE ELECTROTECHNOLOGY

Dhanalakshmi Srinivasan Institute of Technology, Samayapuram, Trichy. Cycle 2 EE6512 Electrical Machines II Lab Manual

MAHARASHTRA STATE BOARD OF TECHNICAL EDUCATION

SECTION 4 TRANSFORMERS. Yilu (Ellen) Liu. Associate Professor Electrical Engineering Department Virginia Tech University

Table of Contents. Table of Figures. Table of Tables

Level 6 Graduate Diploma in Engineering Electro techniques

Electrical Machines (EE-343) For TE (ELECTRICAL)

THE UNIVERSITY OF BRITISH COLUMBIA. Department of Electrical and Computer Engineering. EECE 365: Applied Electronics and Electromechanics

EE 350: Electric Machinery Fundamentals

Placement Paper For Electrical

DEPARTMENT OF ELECTRICAL & ELECTRONICS ENGINEERING 1

Walchand Institute of Technology. Basic Electrical and Electronics Engineering. Transformer

SHRI RAMSWAROOP MEMORIAL COLLEGE OF ENGG. & MANAGEMENT B.Tech. [SEM I (EE, EN, EC, CE)] QUIZ TEST-3 (Session: ) Time: 1 Hour ELECTRICAL ENGINEE

Practical Transformer on Load

Transformers. gpmacademics.weebly.com

CERTIFICATES OF COMPETENCY IN THE MERCHANT NAVY MARINE ENGINEER OFFICER

2015 ELECTRICAL SCIENCE

S J P N Trust's Hirasugar Institute of Technology, Nidasoshi.

1. Explain in detail the constructional details and working of DC motor.

EQUIVALENT CIRCUIT OF A SINGLE-PHASE TRANSFORMER

PESIT Bangalore South Campus Hosur road, 1km before Electronic City, Bengaluru -100 Department of Electronics & Communication Engineering

Chapter 2: Transformers

GATE SOLVED PAPER - EE

EN Assignment No.1 - TRANSFORMERS

No. of Printed Pages : 5 ADVANCED LEVEL CERTIFICATE COURSE IN ELECTRICAL ENGINEERING / DIPLOMA IN ELECTRICAL ENGINEERING / ACELVI / DELVI

TRANSFORMER THEORY. Mutual Induction

WELCOME TO THE LECTURE

Single Phase induction Motor [1/Ch. 36]

CHAPTER 3 EQUIVALENT CIRCUIT AND TWO AXIS MODEL OF DOUBLE WINDING INDUCTION MOTOR

Generator Advanced Concepts

IVE(TY) Department of Engineering. Electrical Machines 1. Electrical Machines 1. Hour 13. slide 1

Introduction : Design detailed: DC Machines Calculation of Armature main Dimensions and flux for pole. Design of Armature Winding & Core.

CERTIFICATES OF COMPETENCY IN THE MERCHANT NAVY MARINE ENGINEER OFFICER

Three-Phase Induction Motors. By Sintayehu Challa ECEg332:-Electrical Machine I

Conventional Paper-II-2013

Cork Institute of Technology. Autumn 2008 Electrical Energy Systems (Time: 3 Hours)

1. A battery has an emf of 12.9 volts and supplies a current of 3.5 A. What is the resistance of the circuit?

QUESTION BANK ETE (17331) CM/IF. Chapter1: DC Circuits

BASIC ELECTRICAL AND ELCTRONICS ENGINEERING LABORATORY LAB MANUAL

Spring 2000 EE361: MIDTERM EXAM 1

ELECTRICAL MACHINES - II COURSEFILE

El-Hawary, M.E. The Transformer Electrical Energy Systems. Series Ed. Leo Grigsby Boca Raton: CRC Press LLC, 2000

Generalized Theory Of Electrical Machines

Electrical Workstation Nvis 7089A

Open Circuit (OC) and Short Circuit (SC) Tests on Single Phase Transformer

GATE 2000 Electrical Engineering

Electrical Workstation Nvis 7089B

Rony Parvej s EEE. Lecture 3 & 4: Transformer. Update: 30 April, fecabook.com/ronyiut

ELG2336 Introduction to Electric Machines

Code No: RR Set No. 1

LECTURE NOTES ON ELECTRICAL MACHINE-II. Subject Code-PCEL4302

Conventional Paper-II-2011 Part-1A

Test. Class 2 Tuesday, February 3,2015. Efficiency Voltage regulation, O.C.& S.C. Tests

AUTO-TRANSFORMER. This is having only one winding; part of this winding is common to both primary and secondary.

ELECTRICAL MEASUREMENTS

MAHARASHTRA STATE BOARD OF TECHNICAL EDUCATION

Question Paper Profile

ECG 741 Power Distribution Transformers. Y. Baghzouz Spring 2014

CHAPTER 4. Distribution Transformers

Transcription:

INSTITUTE OF AERONAUTICAL ENGINEERING (Autonomous) Dundigal, Hyderabad - 00 0 ELECTRICAL AND ELECTRONICS ENGINEERING QUESTION BANK Course Name Course Code Class Branch : ELECRICAL MACHINES - II : A0 : II B.TECH-II SEM : EEE Year : 0-0 Course Faculty OBJECTIVE: : Mr. K Devender Reddy, Assistant Professor As an extension of electrical machines I course this subject facilitates to study of the performance of transformers and induction motors which are the major part of industrial drives and agriculture pump sets. GROUP-I (SHORT ANSWER TYPE QUESTIONS) S. No Question UNIT - I SINGLEPHASE TRANSFORMERS SHORT ANSWER TYPE QUESTIONS Blooms Taxonomy Level Course Outcome Mention the differences between core and shell type transformers. Evaluate Give the EMF equation of a transformer and define each term Apply What are the applications of step-up & step-down transformer? Apply What types of cores are used for transformers? Evaluate Discuss the purpose of Oil used in the transformer. Understand On what size the construction of bushings in a transformer depend? Evaluate Discuss about copper losses in a transformer. Analyze Discuss about Eddy current loss in transformer. Analyze Discuss about Hysteresis loss in a transformer. Analyze Discuss all day efficiency Analyze LONG ANSWER QUESTIONS Give the concept of single phase ideal transformer. Describe its performance with the help of neat phasor diagram Analyze

Explicate in detail with a neat diagram about the constructional details of single phase transformers. Analyze Derive the EMF equation of transformer? Hence derive the voltage ratio. Evaluate What is the efficiency of transformer? How the efficiency of transformer can be calculated? Discuss the effect of variable frequency and supply voltage on iron loss and performance of the transformer? Define voltage regulation of a transformer & enumerate the factors which influence the magnitude of this change? Draw the exact equivalent circuit of a transformer and describe briefly the various parameters involved in it? Define efficiency and all-day efficiency of a transformer. Mention how these are affected by the power factor? Draw the complete phasor diagram for a transformer, when the load power factor is i) Lagging ii) Leading. Discuss the different losses taking place in the transformer and their variation with the load current. ANALYTICAL QUESTIONS A kva 00-0-V, 0 Hz transformer has a magnetic core of 0-cm cross section and a mean length of. cm. The application of 00 V causes magnetic field intensity of 0 AT/m (RMS) and a maximum flux density of. T. Determine i) The turn s ratio ii)the numbers of turns in each winding iii)the magnetizing current The exciting current for a 0 kva, 0/0V 0 Hz transformer is.% of rated current at a phase angle of.0. Find the components of magnetizing current & loss component. Also find the magnetizing reactance & core loss resistance. The voltage ratio of single phase 0 Hz transformer is 000/00 V at no-load. Calculate the number of turns in each winding, if the value of the flux in the core is. mwb The EMF per turn of a - φ, 00/0 V, 0 Hz transformer is approximately V. Calculate i) The number of primary and secondary turns, and ii) The net cross-sectional area of core for a maximum flux density of. T. A 0 KVA, 00/V, 0Hz transformer has a high voltage winding resistance of Ω. The low voltage winding resistance is 0.0Ω and leakage reactance is 0.0Ω. Find the equivalent circuit parameters when referred to the low voltage side. A single phase, 0 Hz core type transformer has square cores of 0 cm side. The permissible flux density in the core is.0 Wb/m. Calculate the number of turns per limb of the high and low voltage sides for a 000/0V ratio. To allow for insulation of stampings, assume the net length to be 0.xGross iron length. KVA transformers has a primary voltage of 000V at 0Hz, primary turns are and secondary turns are 0. Neglecting losses calculate i) No load secondary EMF. ii) Flux in the core Evaluate Analyze Evaluate Evaluate Analyze Apply Evaluate Understand Understand Understand Understand Remember Evaluate Apply

A transformer takes 0.A when its primary is connected to 00V, 0 Hz supply. The secondary is open circuited. The power absorbed from the supply is 0 watts. Determine the iron loss current and magnetizing current. being equally divided between iron and copper. During a day the transformer operates on full load for hours, one half loads for hours and the output being negligible for remaining of the day. Calculate all day efficiency Find the all day efficiency of 00KVA distribution transformer whose cu loss and iron loss at full load are. KW and. KW respectively. During a day of hours, it is loaded under Analyze Apply No ofhrs loadinginkw pf 00 0. 0 0. 0. 0 ----- UNIT- II TESTING OF TRANSFORMERS SHORT ANSWER TYPE QUESTIONS Define voltage regulation of a transformer. What causes a change in secondary terminal voltage of transformer as it is loaded? Does the transformer draw any current when secondary is open Differentiate a classical transformer with an auto transformer. Discuss whether the transformers can be used in parallel What is impedance in transformers? Why is the short circuit test performed at reduced voltage on the HV side? Is the sumpner's test data used for pre-determination of regulation of transformer? Justify the answer. Discuss why Sumpner s test is beneficial for finding efficiency? State any two important conditions to be satisfied for satisfactory and successful operation of transformers connected in parallel. Is the efficiency of a transformer same at the same load at 0. pf lag and 0. pf lead? Apply Remember Apply Apply Analyse Evaluate Understand Remember Remember Evaluate Remember LONG ANSWER QUESTIONS With neat diagram, discuss the various tests to be conducted on transformer to obtain its equivalent circuit. Derive all related equations. Evaluate Describe the tests to be done on a single phase transformer to determine the equivalent circuit parameters. Evaluate Discuss about parallel operation of transformers for unequal voltages ratios. Analyze OC test is preferred to conduct on LV side & SC test is preferred to conduct on HV side. Describe the reasons. Apply

Discuss why parallel operation of transformers is necessary. Under what conditions, the no-load circulating current is zero in two single-phase transformers operating in parallel? Suggest a suitable test to predetermine the efficiency of a transformer and discuss it Describe the method by which the separation of the core losses of a Transformer is achieved. With the help of neat experimental circuit, explain how Sumpner s test is Carried out on a pair of single phase transformer. Derive an expression for load sharing between two transformer operating in Parallel with equal voltage ratios. Evaluate Apply Analyze Evaluate Evaluate Derive an expression for load sharing between two transformer Evaluate ANALYTICAL QUESTIONS A 00 KVA, single - phase transformer is designed to have a resistance of.% and maximum efficiency occurs at a load of. KVA. Find its efficiency when supplying full-load at 0. p.f lagging at normal voltage and frequency. Calculate the regulation of a transformer in which the Ohmic loss is % of the output and the reactance drop is % of the voltage, when the power factor is 0. lagging, leading and unity. A 0 KVA, 0 Hz, 0/00 V, -phase transformer has an efficiency of.% when supplying full- load current at 0. p.f and an efficiency of % when supplying half full-load current at unity p.f. Find the iron losses and copper losses corresponding to full load current Calculate the voltage regulation for a 00/00 V, KVA transformer at full load & pf. 0. lagging with following test data: OC test: 00 V, 0. A, 0 W (LV side) SC test: 0 V, A, 0 W (HV side) Hz, the wattmeter reading on HV side is kw on rated voltage and on LV side is kw when circulated full load current. Find the efficiency of each transformer on /th load & 0. pf lagging. What will be the maximum efficiency of each transformer? The iron loss in a transformer core at normal flux density was measured at frequency of 0 Hz and 0 Hz, the results being 0 W and W respectively. Calculate (i)the hysteresis loss and (ii) The eddy current loss at 0 Hz. The following results were obtained from tests on 0 KVA, 000/ V, and transformer O.C. test: 000 V, 0. A, 0 W S.C. test: V, V, 00W Calculate the efficiency of the transformer at full load with 0. lagging power factor. In a test for determination of the losses of a 0V, 0 Hz transformer, the total iron losses were found to be 00W at normal voltage and frequency. When the applied voltage and frequency were 0V and Hz, the iron losses were found to be 0W. Calculate the eddy current loss at normal voltage and frequency. Calculate the regulation of a transformer in which the Ohmic loss is % of the output and the reactance drop is % of the voltage, when the power factor is 0. lag, lead and unity. Remember Understand Remember Understand Apply Apply Apply Remember Apply

0V/V, KVA transformer has full load unity p.f. efficiency of.%. It is connected as an autotransformer to feed a load at 0V. What is its rating and full load efficiency at 0. p.f. lagging? UNIT - III AUTO AND POLY PHASE TRANSFOMRMERS SHORT ANSWER TYPE QUESTIONS Apply What is an auto transformer? Understand A -phase transformer over a bank of -single phase transformers of equal rating, has the advantage of what? Understand The percentage capacity of V-V bank compared to delta delta is? Evaluate Draw the circuit connection of Delta-Delta. Analyze Draw the circuit connection of Scott Connection. Apply Write about star-star connection in a three a phase transformer. Remember Write about delta-star connection in a three a phase transformer. Remember What are the advantages of Three-phase Transformers? Remember List out at least two essential factors for production of noise in a transformer. Analyze If the polarity of one of the transformer is reversed on a delta bank of single phase transformers that are connected for three phase operation, what would be the result? LONG ANSWER QUESTIONS Analyze Show that an auto-transformer will result in saving copper in place of two winding transformer. Evaluate With neat diagram, discuss the Construction of a three-phase transformer. Evaluate What are the disadvantages of current & voltage harmonics in transformers? Discuss how these harmonics can be eliminated. Describe the two possible ways of connections of -phase transformers with relevant relations amongst voltage and currents Understand Analyze Discuss T-T connection of transformer with the help of neat phasor diagrams. Evaluate With neat diagram describe the Scott connection of a phase transformer. Evaluate Describe the tertiary winding connection of transformer with the help of neat diagrams. With a neat sketch discuss the constructional details of a three phase transformer. Justify that power handling connection. capacity is reduced by.% in Open-delta Describe the advantage of using tertiary in a bank of star-star transformers and List out the merits and demerits of a delta/star connected three phase transformer ANALYTICAL QUESTIONS Evaluate Remember &Evaluate Apply Understand

A phase step down transformer connected in delta/star delivers power to a balanced phase load of KVA at 0. pf. The input line voltage is kv and the turn s ratio of transformer (phase to phase) is. Determine the line voltage line currents, phase voltages, phase currents on both primary &secondary sides. Two single phase furnaces are supplied at 0 V from a. kv, - f system through a pair of Scott connected transformer, if the load on the main transformer is kw at 0. pf lagging and that on the teaser transformer is kw at o. pf lagging. Find the values of line currents on the three phase side. Neglect the losses. A phase, 0 KVA, 000/00 V Star/Star, 0 Hz transformer has an iron loss of 0 W. The maximum efficiency of transformer occurs at 0% of load. Calculate (i) The efficiency of transformer at full load and 0. pf lagging (ii) The maximum efficiency at UPF. A 00 KVA, -phase, 0Hz transformer has a voltage ratio (line voltages) of / KV and is delta/star connected. The resistances per phase are: high voltage Ω, low voltage 0. Ω and the iron loss is 00W. Calculate the value of efficiency at full load and one-half of full load with 0. lagging power factor Two single phase furnaces are supplied at 00 V from a. kv, - f system through a pair of Scott connected transformer, if the load on the main transformer is kw at 0. pf lagging and that on the teaser transformer is kw at o. pf lagging. Find the values of line currents on the three phase side. Neglect the losses. A 00 KVA, -phase, 0 Hz, 000/00V transformer is connected on the HV side and Y connected on the LV side. The resistance of the HV winding in. Ω per phase and that of the LV winding 0.0 Ω per phase. Calculate the iron losses of the transformer at normal voltage and frequency if its full- load efficiency be.% at 0. p.f (lag). A phase, 0 KVA, 000/00 V Star/Star, 0 Hz transformer has an iron loss of 0 W. The maximum efficiency of transformer occurs at 0% of load. Calculate (i) The efficiency of transformer at full load and 0. pf lagging (ii) The maximum efficiency at UPF In a Scott connection, calculate the values of line currents on the Three-phase side, if the loads on the -phase side are 00 KW and 0KW, both at 0V and 0.0 p.f. (lag) and the - phase line voltage is,00v. The 00KW load is on the leading phase on the -phase side. Neglect transformer losses A phase step down transformer is connected to.kv mains and takes A. The ratio of turns per phase is. Neglect losses. Calculate the secondary line voltage, line current and output for the following connections(i) Y/Δ(ii)Δ/Y. Two transformers are connected in open-delta and supply a balanced phase load of 0 KW at 00V and a p.f of 0.. Determine: (i)secondary line current (ii) the kva load on each transformer UNIT - V POLY-PHASE INDUCTION MOTORS SHORT ANSWER TYPE QUESTIONS Understand Evaluate Evaluate Evaluate Analyze Apply Apply Understand Apply Apply In a phase induction motor running at slip s the mechanical power Developed in terms of input power P is. Evaluate What do you mean by AC three-phase induction motor? Understand

On what principle does the induction motor work? analyze What are the types of induction motors? Evaluate What are the main parts of AC three-phase induction motor? Evaluate The starting torque of a three-phase induction motor can be increased by increasing what? In a poly phase squirrel-cage induction motor, increased starting torque can be obtained by Apply Apply The ratio among rotor input, rotor output and rotor Cu losses are? Analyze How a rotor rotates in an Induction motor? Explain. Remember Discuss about slip in an Induction motor. Remember LONG ANSWER QUESTIONS Describe the principle construction and operation of Induction motor. Understand Discuss the various losses taking place in IM. Explain the effect of slip on the Performance of IM. Derive the torque equation of an induction motor. Mention the condition for maximum torque. Understand Analyze Describe how rotating magnetic field is developed in induction motor. Understand Discuss the following (a) How torque is developed in the rotor of a induction motor. (b) Why in some induction motors double cages areprovided? Why the rotor of a poly phase induction motor can never attain synchronous speed? Discuss. Describe the constructional features of both slip ring and squirrel cage induction motor. Discuss the merits of one over the other. Understand Understand Understand With neat diagram describe the equivalent circuit of phase Double Cage IM. Analyze Draw the phasor diagram of an Induction motor and explain. Analyze With a neat sketch discuss the principle of operation of double cage Induction motor Briefly explain the torque slip characteristics of an Induction motor. ANALYTICAL QUESTIONS The frequency of stator EMF is 0 Hz for an -pole induction motor. If the rotor frequency is. hz, calculate the slip and the actual speed of rotor. An pole, phase alternator is coupled to a prime mover running at 0 rpm. It supplies an induction motor which has a full load speed of 0 rpm. Find the number of poles of IM and slip In case of an -pole induction motor the supply frequency was 0 Hz and the shaft speed was rpm. Compute (i) Synchronous speed (ii) Slip speed per unit slip (iii) Percentage slip. A - φ induction motor is wound for poles and is supplied from 0Hz system. Calculate i) Synchronous speed ii) Rotor speed, when slip is % iii) Rotor frequency when rotor runs at 0 rpm. Understand Understand Apply Apply Remember

The EMF in the stator of an pole induction motor has a frequency of 0 Hz and that in the rotor is.hz. At what speed the motor is running and what isc the slip? An -pole, 0 Hz, phase slip ring IM has effective resistance of 0.0 /phase The speed correspond to maximum torque is 0 rpm. What is the value of resistance to be inserted in rotor circuit to obtain maximum torque at starting? A pole, 00 V, phase IM has a standstill rotor EMF of 0 V per phase. The rotor has resistance of 0 Ώ/ph and standstill reactance of 0. Ώ/ph. Calculate the maximum torque & slip at which it occurs. Neglect stator impedance The power input to a 00V, 0Hz, -pole, -phase induction motor running at rpm is 0 KW. The stator losses are KW and the friction and wind age losses total to KW, Calculate i) The slip ii) Rotor copper loss iii) Shaft power. An pole, phase alternator is coupled to an engine running at 0 rpm. The alternator supplies power to an induction motor which has a full load speed of rpm. Find the percentage slip and the number of poles of the motor. 00HP, 0, 0V, 0Hz induction motor has a speed of 0 rpm on full load. The machine has poles. Calculate a) Slip and Speed of rotor field With respect to stator b) Speed of rotor field With respect to stator c) Complete alternations of rotor voltage per minute. d) Relative speed between stator field with respect to rotors. Creating Remember Remember Remember Remember Apply UNIT - V CIRCLE DIAGRAM AND SPEED CONTROL OF INDCUTION MOTORS SHORT ANSWER TYPE QUESTIONS What are the advantages of auto transformer starting? Analyze What are the advantages of slip ring IM over squirrel cage IM? Analyze What is meant by cascade operation? Apply Discuss about direct online starting of an IM? Apply How do changes in supply voltages and frequency affect the performance of an IM? Why no-load current of an Induction motor is much higher than that of an equivalent transformer? In what ratio line current and starting torque is reduced with star- delta starting? Remember Evaluate Apply On what factors does the speed of an Induction motor depends? Analyze Why the induction generator is often called as asynchronous generator? Evaluate What is the application for Induction generators? Apply LONG ANSWER QUESTIONS With neat diagram discuss the various tests to be conducted on phase IM to plot the circle diagram. Compare DOL starter, Auto transformer starter & Rotor resistance starter with relate to the following: (i) starting current (ii) starting torque Apply Evaluate

Calculate the minimum torque. Assume stator and rotor copper Losses equal at standstill. Describe the speed control of IM by rotor resistance control Method. How this method of speed control is different from stator side speed control methods Compare the speed control of phase IM by rotor resistance control & variable frequency control Evaluate Evaluate Apply What happens if the EMF is injected to the rotor circuit of induction motor? Analyse With the help of experimental circuit, describe how the equivalent circuit parameters are determined by no load and blocked rotor tests on phase Induction motor. Apply With the help of a neat diagram, describe the working of a star - delta starter. Apply Discuss the working principle of Induction generator. Analyse Mention the advantages and disadvantages of Induction generator. Apply ANALYTICAL QUESTIONS A cage IM when started by means of a star-delta starter takes % of full load current & develops % of full load torque at starting. Calculate the starting current & torque in terms of full load torque when started by means of an auto transformer with % tapping. A -phase, 00V induction motor has the following test readings:- No-load:- 00V, W, A Short circuit:- V, KW, A Draw the circle diagram. If the normal rating is. KW, find from the circle diagram, the full load value of current, power factor and slip. A pole, 0 Hz, wound rotor IM has a rotor resistance of 0. ph and runs at 0 rpm at full load. Calculate the additional resistance per phase to be inserted in the rotor circuit to lower the speed to 0 rpm, if the torque remains constant. Two 0Hz, phase induction motors having six and four poles respectively are cumulatively cascaded, the pole motor being connected to the main supply. Determine the frequencies of the rotor currents and the slips refereed to each stator field if the set has a slip of %. A phase, pole 0Hz induction motor when fully loaded, runs with a slip of %. Find the value of resistance necessary in series per phase of the rotor to reduce the speed by %. Assume that the resistance of the rotor per phase is 0. ohm. Two slip ring IMs having & poles respectively are mechanically coupled. i. Calculate the possible speed when first motor is supplied from a 0 Hz supply line. ii. Calculate the ratio of power shared by the two motors. iii. If the smallest possible speed is to be attained independently by each machine, calculate the frequency of the voltage to be injected in the rotor circuit A pole, 0 Hz, phase induction motor is running at percent slip when delivering full load torque. It has standstill rotor resistance of 0. ohm and reactance of 0. ohm per phase. Calculate the speed of the motor if an additional resistance of 0. ohm per phase is inserted in the rotor circuit. The full load torque remains constant Creating Remember Remember Remember apply Remember Apply

Two 0 Hz, phase Induction motors having six and four poles respectively are cumulatively cascaded, the pole motor being connected to the main supply. Determine the frequency of the rotor currents and the slips referred to each stator field if the set has a slip of%. A 0 KVA, 00V, phase, 0 Hz squirrel cage Induction motor has full load slip of %. Its standstill impedance is 0. ohms per phase. It is started using a tapped auto transformer. If the maximum allowable supply current at the time of starting is 0A, calculate the tap position and the ratio of starting torque to full load. A three-phase delta-connected cage type induction, motor when connected directly to a 00 V, 0Hz supply, takes a starting current of 0 A, in each stator phase. Calculate i) The line current for `direct--on-line starting. Evaluate Understand Apply