Transitioning analytical instrumentation from the laboratory to harsh environments*

Similar documents
Technology readiness applied to materials for fusion applications

Technology Readiness Assessment of Department of Energy Waste Processing Facilities: When is a Technology Ready for Insertion?

Intermediate Systems Acquisition Course. Lesson 2.2 Selecting the Best Technical Alternative. Selecting the Best Technical Alternative

WHO WE ARE MISSION STATEMENT

Technology readiness evaluations for fusion materials science & technology

Realization of Fusion Energy: How? When?

Committee on Astrobiology & Planetary Science (CAPS) Michael H. New, PhD Astrobiology Discipline Scientist

The use of technical readiness levels in planning the fusion energy development

Mid Term Exam SES 405 Exploration Systems Engineering 3 March Your Name

ROI of Technology Readiness Assessments Using Real Options: An Analysis of GAO Data from 62 U.S. DoD Programs by David F. Rico

REQUEST FOR INFORMATION (RFI) United States Marine Corps Experimental Forward Operating Base (ExFOB) 2014

Readiness Assessment for Video Cell Phones SE 602

Model Based Systems Engineering (MBSE) Business Case Considerations An Enabler of Risk Reduction

Jerome Tzau TARDEC System Engineering Group. UNCLASSIFIED: Distribution Statement A. Approved for public release. 14 th Annual NDIA SE Conf Oct 2011

I. INTRODUCTION A. CAPITALIZING ON BASIC RESEARCH

Pharmaceutical Manufacturing and Engineering Catalog Excerpt

Manufacturing Readiness Assessment Overview

Manufacturing Readiness Assessments of Technology Development Projects

Model Based Design Of Medical Devices

Moving from R&D to Manufacture

Finishing first how automated systems improve the productivity and repeatability of wafer lapping and polishing

LC/MS/MS. Page Header. triple quadrupole mass spectrometer.

1.1 PHILOSOPHY OF MICRO/NANOFABRICATION

Solution of Pipeline Vibration Problems By New Field-Measurement Technique

Module 2 Lesson 201 Project Coordinator (PC) Duties

NASA Cost Symposium Multivariable Instrument Cost Model-TRL (MICM-TRL)

MAKING IOT SENSOR SOLUTIONS FUTURE-PROOF AT SCALE

Air Force Small Business Innovation Research (SBIR) Program

Why select a BOS zoom lens over a COTS lens?

April 10, Develop and demonstrate technologies needed to remotely detect the early stages of a proliferant nation=s nuclear weapons program.

DMTC Guideline - Technology Readiness Levels

Highways, ring road, expressways of tomorrow in the Greater Paris

Diode Laser Systems In Gas Measurement

Trends of China Die & Mould. The Situation and Development. Industry. China Die & Mould Industry Association

Moving from R&D to Manufacture

TESA HITE - TESA MICRO-HITE

Ground Systems Department

Technology Readiness Levels for Partitioning and Transmutation of Minor Actinides in Japan

THE LABORATORY ANIMAL BREEDERS ASSOCIATION OF GREAT BRITAIN

Solutions for the Industrial and Safety Markets

GAO Technology Readiness Assessment Guide: Best Practices for Evaluating and Managing Technology Risk in Capital Acquisition Programs

PERFORMANCE OF A NEW MEMS MEASUREMENT MICROPHONE AND ITS POTENTIAL APPLICATION

Workshop is experiencing a loss of power. Please standby.

CONTACT DETAILS. NNC s Leak Sealing Services. Greg Willetts, Head Of Leak Sealing Services. Phone: +44 (0)

Reducing Manufacturing Risk Manufacturing Readiness Levels

COMMERCIAL INDUSTRY RESEARCH AND DEVELOPMENT BEST PRACTICES Richard Van Atta

Technology Evaluation. David A. Berg Queen s University Kingston, ON November 28, 2017

Financial Highlights. Letter to Shareholders. Annual Report

Observations and Recommendations by JPL

Experimental Analysis of Luminescence in Printed Materials

Advanced Control Foundation: Tools, Techniques and Applications. Terrence Blevins Willy K. Wojsznis Mark Nixon

Technology Development Stages and Market Readiness

EU Support for SME Innovation: The SME Instrument

Understand that technology has different levels of maturity and that lower maturity levels come with higher risks.

Grade Descriptors: Design & Technology

Evaluation of high power laser diodes for space applications: effects of the gaseous environment

Program Success Through SE Discipline in Technology Maturity. Mr. Chris DiPetto Deputy Director Developmental Test & Evaluation October 24, 2006

Application of Safeguards Procedures

Application of Visible-Residue Limit for Cleaning Validation Richard J. Forsyth and Vincent Van Nostrand By Richard J. Forsyth,Vincent Van Nostrand

Maximizing Innovation Funding for Technology Development. MNP SR&ED Team. Presented by: Date:

TRL Corollaries for Practice-Based Technologies

Prototyping: Accelerating the Adoption of Transformative Capabilities

Arshad Mansoor, Sr. Vice President, Research & Development INNOVATION SCOUTS: EXPANDING EPRI S TECHNOLOGY INNOVATION NETWORK

Design and Operation of Micro-Gravity Dynamics and Controls Laboratories

Development of Explosion-proof Autonomous Plant Operation Robot for Petrochemical Plants

5th International Symposium - Supercritical CO2 Power Cycles March 28-31, 2016

ETP ELECTRON MULTIPLIERS

INFRARED ANALYSIS OF SINGLE AND MULTILAYER FILMS IN THE PRODUCTION AREA

This document is a preview generated by EVS

MEMS Spectroscopy Overview

Antennas For Aerospace and Defense

Technology and Manufacturing Readiness Levels [Draft]

Interagency IED Defeat Research and Development. Global EOD Conference and Exhibition May 4-5, 2011 Fort Walton Beach, FL

Department of Energy Technology Readiness Assessments Process Guide and Training Plan

Electrical Equipment Condition Assessment

Software-Intensive Systems Producibility

Robotics in Horizon 2020 IMPACT and Technology Readiness Levels

Air Force Research Laboratory

Profiling of Volatile Organic Compounds in Milk and Orange Juice Using Headspace Analysis

SIMULATION-BASED ACQUISITION: AN IMPETUS FOR CHANGE. Wayne J. Davis

Logic Solver for Tank Overfill Protection

Facilitating Human System Integration Methods within the Acquisition Process

U.S. ARMY RESEARCH, DEVELOPMENT AND ENGINEERING COMMAND

X-Supreme8000. A powerful innovative XRF analytical solution combining performance with flexibility

ETP ELECTRON MULTIPLIERS

National Shipbuilding Research Program

Manufacturing Readiness Levels (MRLs) and Manufacturing Readiness Assessments (MRAs)

Determination of the N-Nitrosamine Content in Rubber Articles Using the Agilent 7000A Triple Quadrupole GC/MS System

Spark Spectral Sensor Offers Advantages

WHITE PAPER FACILITY FOCUS: Next Generation Aseptic Manufacturing: An Eye-Opening Peek into the Future. By: Hite Baker

Carbide Doctor Blades on Ceramic Press Rolls

THIS IS INNOVATION Compound Semiconductors

Where tax and science meet part 2*

Hermetic Packaging Solutions using Borosilicate Glass Thin Films. Lithoglas Hermetic Packaging Solutions using Borosilicate Glass Thin Films

Lesson 17: Science and Technology in the Acquisition Process

in the New Zealand Curriculum

NZQA Expiring unit standard version 3 Page 1 of 8. Operate bitumen handbar sprayer equipment, and handspray bitumen for chipseal surfacing

Multi-channel telemetry solutions

Introduction INTRODUCTION DISCOVER THE NEXT GENERATION IN EDGE WELDED METAL BELLOWS

GaN Reliability Report 2018

Transcription:

Pure Appl. Chem., Vol. 74, No. 12, pp. 2317 2322, 2002. 2002 IUPAC Transitioning analytical instrumentation from the laboratory to harsh environments* R. B. Turner Smiths Detection, 459 Park Avenue, Bushey, Watford, Hertfordshire, WD23 2BW, UK Abstract: The development of sensitive analytical instrumentation for autonomous operation in harsh environments is a difficult and expensive process. The management of risk in this process is aided by the use of technology readiness levels (TRLs) and awareness that the exponential growth of costs through development militates very strongly against progressing the development prematurely. It is also essential to have a very clear view of the intended outcome at the earliest possible stage and to test the systems in realistic environments as soon and as often as possible. Economic production of large quantities of instruments requires considerable attention to the details of the production process and the control of materials; there is a constant battle against contamination. Future instrumentation might involve a combination of analytical techniques, but the desire for more selectivity and sensitivity must be balanced against cost, complexity, and reliability. INTRODUCTION For nearly 20 years, my company has been involved with the design and development of instruments employed in the field to detect traces of chemicals including illicit drugs, explosives, and chemical warfare agents. These instruments, mainly based on ion mobility spectrometry (IMS) [1,2], include the chemical agent monitor (CAM) shown in Fig. 1, the automatic chemical agent alarm (GID-3 ACADA) shown in Fig. 2, and the volatile organics analyzer (VOA) [3], which is currently in operation on the International Space Station. Fig. 1 Chemical agent monitor (CAM). *Lecture presented at the IUPAC Workshop, Impact of Scientific Developments on the Chemical Weapons Convention, Bergen, Norway, 30 June 3 July 2002. Other presentations are published in this issue, pp. 2229 2322. 2317

2318 R. B. TURNER Fig. 2 GID-3 ACADA. We generally hope to manufacture thousands of each instrument over 50 000 CAMs have been made although the VOA is an exception for obvious reasons. Our products are sensitive (generally in the region of parts per billion or lower), rugged, and automatic (they do not require the operator to interpret the results). In this article, I describe some aspects of the process by which technology is taken from the laboratory to use in demanding environments and some of the particular problems that have been encountered in the manufacture of trace detectors. PRODUCT DEVELOPMENT The development of a new product requires investment. In order to justify this investment, a number of questions should be asked and answered before the process can start. These questions include: What are the technological risks in the proposed development? What are the estimated costs of the proposed development? What is the proposed time scale? What is the prospective market does this justify the investment? The management of risks in high technology development has become an area of focus for governments and industry largely as a result of bitter experience. TECHNOLOGY READINESS One way of looking at the risks involved in the development of technology into products was developed by NASA in the late 1990s and has subsequently been employed by both the U.S. [4] and U.K. governments. In this methodology, there are nine TRLs defined briefly as follows: 1. Basic principles of technology observed and reported 2. Concept and/or application formulated 3. Analytical and laboratory studies to validate analytical predictions 4. Component and/or basic subsystem technology validated in lab environment 5. Component and/or basic subsystem technology validated in relevant environment 6. System/subsystem technology model or prototype demonstrated in relevant environment 7. System technology prototype demonstrated in an operational environment

Transitioning analytical instrumentation from the laboratory to harsh environments 2319 8. System technology qualified through test and demonstration 9. System technology qualified through successful mission operations The costs involved in the development of a new product rise exponentially as the program moves through the various stages. Conversely, the risks (both technical and in time scale) should fall as the program approaches completion. One of the objectives of the technology readiness approach is to ensure that an appropriate level of technological maturity has been reached before major investment is made. This does not generally mean that all the risks disappear before the end of the project, but they do change in nature. Early in the process, the scientific risks will predominate. Risks in the later stages will be mainly associated with engineering issues. It is extremely important to have an accurate specification of the final system; this implies a very clear view of the purpose and modes of use. The specification must be complete, but not excessive. For example, if the equipment is required to be operational within 5 min after long storage then this must be explicitly stated in the specification it is very difficult to prevent long-term build-up of contamination when trace detectors are stored. On the other hand, asking for high measurement accuracy when only qualitative results are really needed can lead to high cost for no purpose. COSTS OF DEVELOPMENT The two most recent development programs that we have carried out were both essentially modifications of technology that had already been proven in previous products corresponding to level 5 in the readiness scale. Each of these programs has cost approximately $3 million and involved teams of about 20 people. The development teams include a mix of disciplines scientists, mechanical engineers, electronics (analog and digital) engineers, production engineers, process engineers, software engineers, safety engineers, test engineers, and logistics experts, in addition to a planner and a project manager. The development time (from level 5 to level 9) is typically 1.5 2 years. Our development programs involve a considerable amount of time and effort in testing; this starts to consume serious money at TRLs 5 and 6. The tests range from relatively straightforward environmental tests for ruggedness to operational tests in realistic environments. The latter should be carried out as soon as practical and as extensively as possible; we have had some unpleasant shocks as a consequence of a lack of knowledge of the chemical background. WHERE DOES ALL THE MONEY GO? It is not necessarily the most scientifically challenging areas that take the most resources in the development process. One of the most difficult aspects of the design of portable instrumentation is packaging how to get all the electronics, pumps, sensors, displays, and input/output interfaces in the most compact and ergonomic form. The outside case of the instrument can often be one of the most expensive items both to design and to purchase. The case has to provide electrical screening for both radiofrequency emissions from the instrument and to prevent external fields from affecting its operation. It has to be sealed against the elements, and it must be easy to assemble. It has to be as light as possible, and yet it must be robust. DESIGNING FOR PRODUCTION Trained and experienced people can assemble a small number of instruments using experience and knowledge to tackle any problems that arise. However, this approach becomes less and less viable as the production rate rises and larger numbers of people must be involved. Documentation both of the product and the process becomes vital, and considerable effort can be expended in establishing processes that are robust and a design that can be reliably reproduced with the minimum of specialist

2320 R. B. TURNER knowledge or black art. At TRLs 6 and 7, the investment in production tooling and process engineering becomes significant. Designing the membrane Whereas it is desirable to control or specify all aspects of manufacture, sometimes this is not achievable. For example, a simple but vital component in some of our instruments is a thin (12 µm) silicone rubber membrane (shown in Fig. 3 mounted on a holder). This membrane acts as the inlet to the system; sample vapors dissolve in it and permeate through to the analyzer within the instrument. The membrane provides selectivity (particularly against water vapor), and it prevents contamination from dust. Each membrane was individually tested (this of course is a waste we would prefer that they be 100 % leak-free), and a high and variable failure rate was observed. Test results varied from 90 % pass to 90 % fail on a batch-to-batch basis. The problem was tackled systematically; initially the processes within the company were refined to ensure that the handling, assembly and test were not contributory factors. The failure mechanism was analyzed and determined to be primarily a result of particle inclusion a 10-µm particle in a 12-µm membrane is clearly going to lead to problems. Next, the subcontractors who mold the item were involved, and clean-room processes and environments were instigated. The net result was a reduction in failure rate but we still had failures. Discussions with the supplier of the bulk silicone revealed that whereas the material is made in a relatively clean area, it is not a filtered air facility. They were unwilling to install an expensive plant and implement cost-raising procedures to satisfy a customer who purchased less than 0.01 % of their output. We still live with testing (and failing) membranes. Fig. 3 The membrane. Contamination in trace detector manufacture For trace detection equipment, ensuring adequate cleaning of components used in the sensor assembly becomes a key issue. A significant proportion of the space on our production floor is occupied by washing and baking machinery. Contamination of the air supplies that are used to purge the ovens can stop the production process, so these are continuously monitored and a back-up supply is available. The production process sometimes appears to be a continuous fight against contamination. We have had problems with pollution from traffic and from solvent emitted from a factory next door although these are well below permitted levels. We have to control the polish on the factory floors and production operators perfumes and deodorants.

Transitioning analytical instrumentation from the laboratory to harsh environments 2321 Designing the pump We designed a miniature diaphragm pump (Fig. 4) to circulate air within one of our instruments. In order to keep the costs reasonable, it is constructed of a number of molded plastic components. After a great deal of testing and experimentation, a particular grade of polypropylene was chosen as providing the right combination of chemical cleanliness (after a washing and baking process) and mechanical properties. The production of large quantities commenced, and all went well for a year or so. Then it was noticed during the test of completed instruments that contamination had started to appear. Every polypropylene component in the factory was found to be grossly contaminated. The investigating team was spurred on by a production line with no output and various offers of help from senior management. They eventually found that the supplier of the polypropylene molding granules had closed down the plant that supplied the original material and had moved production to a new plant in a different country. This new plant used a different antioxidant in the formulation, so that whereas the product met the manufacturer s specification it did not meet our more stringent requirements. Current procedures call for batch testing of molded components to detect such problems at an early stage. Fig. 4 The pump. THOUGHTS ON FUTURE INSTRUMENTATION There is a continual demand for instruments of greater sensitivity. As sensitivity levels are pushed higher, more problems are encountered with the chemical background (these problems might be most severe in industrial facilities). More selectivity must go hand-in-hand with greater sensitivity. Approaches for higher selectivity include the use of a separation stage such as gas chromatography. However, this gives penalties in the form of increased complexity, longer analysis times, and problems with the provision of inert carrier gas. Adding chromatography to a detection technique that shows extreme sensitivity toward specific groups of materials can produce a system that combines both selectivity and sensitivity. One example of this is the chemiluminescent method for the detection of explosives. This is an excellent method for explosives that contain nitrogen. However, increased use by terrorists of explosives based on peroxides makes the method redundant. To make a technique future-proof, it must be capable of responding to as wide a range of compounds as possible, which places even more demands on selectivity. Combining techniques that rely on different principles for their operation is an attractive approach for trace detection. Examples might be combinations of IMS and cavity ring-down spectrometers [5]. These techniques are extremely sensitive and sufficiently small to make a combination possible in a portable instrument. Target materials might be more reliably confirmed by detection by multiple tech-

2322 R. B. TURNER niques. Unfortunately, the fact that the methods measure different parameters is not a guarantee that they will together give more discrimination. In fact, one might take the opposite view based on the fact that they all respond to the target set of materials. Cost and reliability would both be adversely affected by the inevitable increase in complexity inherent in the use of multiple analytical techniques. Whether any gain in performance is balanced by these adverse factors will probably not be known until such a project is attempted. CONCLUSION Designing and manufacturing sensitive portable instrumentation is an expensive, complex, and risky activity. Before undertaking such a task, it is essential to have a very clear view of the desired objective. At the earliest possible stage, the specification should be detailed, and its practicality should be determined by testing in a realistic environment. Major effort should be devoted to the management and amelioration of risk. REFERENCES 1. G. A. Eiceman and Z. Karpas. Ion Mobility Spectrometry, CRC Press, Boca Raton, FL (1994). 2. R. B. Turner and J. L. Brokenshire. Trends Anal. Chem. 13 (7), 275 280 (1994). 3. P. G. Bass. Spaceflight 42, 139 144 (2000). 4. DoD 5000.2-R, Mandatory Procedures for Major Defense Acquisition Programs (MDAPs) and Major Automated Information System (MAIS) Acquisition Programs. 5. R. J. Saykally and R. Casaes. Laser Focus World 37, 159 162 (2001).