Fiber Distance* (note2) Temp. Connector DDM

Similar documents
SFP Series. EOLS-BI Series EOLS-BI Series. Features. Applications. Ordering information

SFP Module DB1310-SFP-SC.S20 DB1550-SFP-SC.S20. Features. Applications. Ordering information

SFP Series. EOLS-BI Series EOLS-BI Series. Features. Applications. Ordering information

BIDI SFP Series. Part No. Data Rate Wavelength Interface Temp. DDMI

Part No. Data Rate Wavelength Interface Temp. DDMI /1.25Gbps 1310nm SC Industrial NO EOLS-BI I

EOLS-1312-XXXX 1.25Gbps SFP Transceiver

SFP Series EOLS-BI Series EOLS-BI Series

SFP28 Series Preliminary EOLP-8525G-02-R. Features. Applications. Ordering information

SFP+ Series EOLP M-I. Features. Applications. Ordering information

SFP Series. EOLS-1348-X Series. Features. Applications. Ordering Information. Single-Mode 1310nm FC/2FC/4FC Duplex SFP Transceiver RoHS6 Compliant

SFP Series. Single-Mode 1310nm for GE, STM1/STM4/STM16, FC/2XFC Duplex SFP Transceiver RoHS6 Compliant. Distance * (note2) Interface Temp. DDMI.

850nm SFP28 Multi-Mode Transceiver, With Diagnostic Monitoring and Dual CDR Duplex SFP28 Transceiver, RoHS 6 Compliant. Fiber Type.

SFP Series IOLS-1348-XXXX. 4.25Gbps up to 30 km transmission. version 0.1 FEATURES PRODUCT DESCRIPTION

SFP+ BIDI Series JB1270-SFP-LC.S40. Features. Applications. Ordering information

SFF Series EOLF Series EOLF Series

2.5Gbps SFP Transceiver

SFP Series. EOLS X Series. Features. Applications. Ordering Information

DWDM SFP+ Series DWDM EML

4.25Gbps SFP Transceiver

DWDM SFP+ Series. EOLP XXXN series. Features. Applications. Ordering Information

DWDM SFP Series. Laser

SFP Series EOLS X. Features. Applications. Ordering Information

DWDM SFP+ Series DWDM EML DWDM EML

Regulatory Compliance Electrostatic Discharge (ESD) to the Electrical Pins Electrostatic Discharge to the enclosure Electromagnetic Interference (EMI)

SFP Series. Distance * (note2) Interface Temp. DDMI

SFF Series EOLF Series

CWDM EML. SMF 23dB YES LC. note1: X refers to CWDM Wavelength range 1470nm to 1610nm, X=K~R, denotes 1470~1610nm.

DWDM SFP+ single-mode Transceiver, With Diagnostic Monitoring Multi-rate 16x / 8x / 4x Fibre Channel Duplex SFP+ Transceiver, RoHS 6 Compliant

SNR-SFP-LX 1.25Gbps. Features. Applications. Product Description

DWDM SFP+ Series. EOLP XXXN MSA Series. Features. Applications. Ordering Information

1550nm SFP+ single-mode Transceiver, With Diagnostic Monitoring Duplex SFP+ Transceiver RoHS 6 Compliant

SO-CSFP-100Base-BX20D-34-O2 -I

SFP Series. Features. Applications. Ordering information. Single-Mode 155Mbps SC Single-Fiber SFP Transceiver RoHS6 Compliant

SFP+ Series EOLP XN MSA Series

1310nm SFP+ single-mode Transceiver, With Diagnostic Monitoring 10G BASE-LW/LR 0.6~10Gbps CPRI/OBSAI Duplex SFP+ Transceiver, RoHS 6 Compliant

SFF Series. EOLF Series. Features. Applications. Ordering Information. Multi-Mode 850nm 1250Mbps Duplex SFF Transceiver RoHS6 Compliant

DWDM SFP Series. Power budget* (note2) Laser

SFP Series. EOLS-1312-X Series. Features. Applications. Ordering Information. Single-Mode 1310nm 1.25Gbps FC/GBE Duplex SFP Transceiver RoHS Compliant

1.25Gbps SFP Transceiver

OCTECH 1.25Gbps SFP Transceiver

DWDM SFP Series. Power budget* (note2) Laser

OCTECH 1.25Gbps SFP Transceiver

SFP+ Series SFP-10G-SR

1310nm SFP+ single-mode Transceiver, With Diagnostic Monitoring 10G BASE-EW/ER Duplex SFP+ Transceiver, RoHS 6 Compliant. Fiber Type.

SFP-CWDMxx.60. CWDM* Wavelength (0 to 70 o C)

DWDM SFP+ single-mode Transceiver, With Diagnostic Monitoring Multi-rate 16x / 8x / 4x Fibre Channel Duplex SFP+ Transceiver, RoHS 6 Compliant

SFP Series IOLS-1624-XX-XX. 2.5Gbps APD High Sensitivity Receiver. version 0.1 FEATURES PRODUCT DESCRIPTION

SFP Series. EOLS-BI CL XX Series EOLS-BI LC XX Series. Features. Applications. Ordering Information

DWDM SFP+ Series EOLP XXN MSA Series

SFP Series. Fiber Distance* (note2) Interface Temp. DDMI

SFP-BIDI G 1310/1490nm BIDI

SFP+ BIDI Series EOLP-BI1696-9ADL & EOLP-BI1696-9DAL Series

DWDM SFP Series. Power budget* (note2) Laser

SFP Series. Single-Mode 1310nm for GE, STM1/STM4/STM16, FC/2XFC Duplex SFP Transceiver RoHS6 Compliant. Distance * (note1) Interface Temp. DDMI.

SFP+ Series EOLP Features. Applications. Ordering information

1310nm SFP+ single-mode Transceiver, With Diagnostic Monitoring 10G BASE-LW/LR 0.6~10Gb/s CPRI/OBSAI Duplex SFP+ Transceiver, RoHS 6 Compliant

DWDM SFP Series. DIxx-SFP-LC.S120. Features. Applications. Ordering Information

1310nm SFP+ single-mode Transceiver, With Diagnostic Monitoring 10G BASE-LW/LR 0.6~10Gb/s CPRI/OBSAI Duplex SFP+ Transceiver, RoHS 6 Compliant

Fiber Distance* (note2) Interface Temperature DDMI Rate

SFP+ Tunable Preliminary. EOLP-1696-TDW-23XXXN MSA Series. Features. Applications. Ordering Information

SFP+ BIDI Series GigaStream BIDI-10G-SFP-40A & BIDI-10G-SFP-40B

Part No. Input Output Burst-mode Fiber Interface Temp.

SFP+ Series. 1550nm SFP+ single-mode Transceiver, With Diagnostic Monitoring Duplex SFP+ Transceiver RoHS 6 Compliant

GLC-GE-100FX-LEG. 155Mbps SFP Transceiver

Regulatory Compliance Feature Standard Performance Electrostatic Discharge (ESD) to the Electrical Pins Electrostatic Discharge To the enclosure Elect

SFP+ BIDI Series JB1270-SFP-LC.S20

SFP Series. EOLS X Series. Features. Applications. Ordering Information. Multi-Mode 850nm 1xFC /GBE Duplex SFP Transceiver RoHS6 Compliant

PON Series. EOLS-GN- 25-XX Series. Features. Applications. Ordering Information. Link Budget. Input/ Output. DDMI Interface Temp. Part No.

SO-SFP-1000BASE-ZXD-I

Fiber Channel Links Standard: 0 ~+70 Industrial: -40 ~+85 Compliant with GBIC Specification Rev. 5.5

10G PON Series Preliminary

SFP BIDI 2.5Gbps 40Km Tx1310/Rx1550nm / Tx1550/Rx1310nm

Note1: Standard version, the distance is measured under Lab condition. For other ordering information in detail, please contact EOPTOLINK..

SFP+-CWDM-xx-40D. 10Gbps CWDM SFP+ Optical Transceiver, 40km Reach

DATASHEET 4.1. SFP, 100Mbps-2.7Gbps, Multirate, 1310nm, SM, DDM, 8dB, 2km, ind.temp.

Optical Transceiver Module - SFP

SFP+-10GB-ZR. 10Gbps SFP+ Optical Transceiver, 80km Reach

SGMII SFP 125Mbps 1310nm MMF 2KM SLSG D

ASF Features. Applications. 1310nm SFP Single-Mode for 1.25G FC/GBE Duplex SFP Transceiver RoHS 6 Compliant

SFP Series. Single-Mode 1310nm for GE, STM1/STM4/STM16, FC/2XFC Duplex SFP Transceiver RoHS6 Compliant. Distance * (note2) Interface Temp. DDMI.

SFP+-DWDM-xx-80D. 10Gbps DWDM SFP+ Optical Transceiver, 80km Reach

SFP28 Series Preliminary EOLP-1325G-10-RX. Features. Applications. Ordering information

DWDM SFP Series. Laser

1310nm SFP28 Single-Mode Transceiver, With DDM and Dual CDR Duplex SFP28 Transceiver, RoHS 6 Compliant. Fiber Type Gbps 1310nm and DFB 28.

Part No. Data Rate Fiber Distance Interface Temperature DDMI

Part No. Data Rate Wavelength Interface Temp. DDMI

SFP Dual LC 1.25G SMF 20Km 1310nm Transceiver. Features. Applications. Ordering Information APPLIED OPTOELECTRONICS, INC.

1/12. SFP модули. Модели SFP-DWDM-GE-15xx.xx-28. Особенности: - 100Mbps Gbps - встроенная функция диагностики (DDMI)

SFP-1.25G-LX 1.25Gbps SFP Optical Transceiver, 10KM Reach

GPON ONU Series. EOLF-GU5-25-P Series. Features. Applications. Ordering Information. Case Temperature. Part No. Input Output Burst-mode Interface

SNR-SFP+W73-20 SNR-SFP+W db Power Budget BIDI SFP+ 10GbE Transceiver

Features. RX Sensitivity (dbm) TX Power (dbm) Voltage (V) SFP-Dual-LC 1.25G MMF 2Km ~ -9 < AC/AC TTL N -5 ~ +70 A56L-BN13-A6MA

GBIC BIDI Series. EOLG-BI1X12-2M series. Features. Applications. Ordering information

QSFP+ Series Preliminary EOLQ-8540G-03-MO Series

1.25Gbps SFP Optical Transceiver, 550m Reach EP-8524-S5x(D)

PT (2)-1W. OC-3 SR/IR-1 / STM S-1.1 SFP Transceiver

SNR-SFP+LR-2 10Gbps. Applications 10GBASE-LR at 10.31Gbps 10GBASE-LW at 9.95Gbps Other optical links

10G EPON Series. EOLS-PR-GEU-10 Series Preliminary. Features. Applications. Ordering information. Regulatory Compliance. Burst-M Part No.

Part No. Input Output Burst-Mode Fiber Interface Temp. Feature Standard Performance. Class 1C (>1000 V) Method 3015.

SO-SFP-10GE-BX10D-3327-E

Transcription:

EOLS-BI1X03-2M Series Multi-Mode 155Mbps SC/LC Single-Fiber SFP Transceiver RoHS6 Compliant Features Operating data rate up to 155Mbps A type: 1310nm FP Tx/1550nm Rx B type: 1550nm FP Tx/1310nm Rx 2km with 50/125µm MMF(800Mhz*km) 1km with 62.5/125µm MMF(500Mhz*km) Single 3.3V Power supply and TTL Logic Interface Hot Pluggable Operation case temperature range: Standard: 0~+70 Industrial:-40~+85 Compliant with MSA SFP Specification Digital diagnostic monitor interface Applications WDM Fast Ethernet Links SONET/SDH Equipment Interconnect Fiber Channel Links Other Optical Transmission Systems Compatible with SFF-8472 Ordering Information Part No. Data Rate Fiber Distance* (note2) Temp. Connector DDM EOLS-BI1303-2M* note1 155Mbps MMF 1~2km Standard SC NO EOLS-BI1303-2M-D 155Mbps MMF 1~2km Standard SC YES EOLS-BI1303-2M-I 155Mbps MMF 1~2km Industrial SC NO EOLS-BI1303-2M-DI 155Mbps MMF 1~2km Industrial SC YES EOLS-BI1503-2M * note1 155Mbps MMF 1~2km Standard SC NO EOLS-BI1503-2M-D* note1 155Mbps MMF 1~2km Standard SC Yes EOLS-BI1503-2M-I 155Mbps MMF 1~2km Industrial SC NO EOLS-BI1503-2M-DI 155Mbps MMF 1~2km Industrial SC Yes EOLS-BI1303-2M-L* note1 155Mbps MMF 1~2km Standard LC NO EOLS-BI1303-2M-DL 155Mbps MMF 1~2km Standard LC YES EOLS-BI1303-2M-IL 155Mbps MMF 1~2km Industrial LC NO Page 1 of 11

EOLS-BI1303-2M-DIL 155Mbps MMF 1~2km Industrial LC YES EOLS-BI1503-2M-L* note1 155Mbps MMF 1~2km Standard LC NO EOLS-BI1503-2M-DL 155Mbps MMF 1~2km Standard LC Yes EOLS-BI1503-2M-IL 155Mbps MMF 1~2km Industrial LC NO EOLS-BI1503-2M-DIL 155Mbps MMF 1~2km Industrial LC Yes Note1: Standard version Note2: 1km with 62.5/125um MMF (500Mhz.km). 2km with 50/125um MMF (800Mhz.km) *The product image only for reference purpose. Regulatory Compliance* Product Certificate Certificate Number Applicable Standard EN 60950-1:2006+A11+A1+A12+A2 TUV UL R50135086 E317337 EMC CE AE 50285865 0001 EN 60825-1:2014 EN 60825-2:2004+A1+A2 UL 60950-1 CSA C22.2 No. 60950-1-07 EN 55022:2010 EN 55024:2010 FCC WTF14F0514417E 47 CFR PART 15 OCT., 2013 FDA / CDRH 1040.10 ROHS / 2011/65/EU *The above certificate number updated to June 2014, because some certificate will be updated every year, such as FDA and ROHS. For the latest certification information, please check with Eoptolink. Product Description The EOLS-BI1X03-2M-X series is small form factor pluggable module for IEEE 802.3ah 100BASE-BX10 and OC-3/STM-1 SONET/SDH single fiber communications by using 1310 nm/1550nm transmitter and 1550nm/1310nm receiver. It is with the SFP 20-pin connector to allow hot plug capability. The transmitter section uses a multiple quantum well A type/ B type laser and is a class 1 laser compliant according to International Safety Standard IEC 60825. The receiver section uses an integrated A type/ B type detector preamplifier (IDP) mounted in an optical header and a limiting post-amplifier IC. The EOLS-BI1X03-2M-XD series are designed to be compliant with SFF-8472 SFP. Absolute Maximum Ratings Parameter Symbol Min. Max. Unit Storage Temperature Ts -40 +85 C Supply Voltage Vcc -0.5 3.6 V Page 2 of 11

Operating Relative Humidity - 5 95 % Recommended Operating Conditions Parameter Symbol Min. Typical Max. Unit Operating Case Temperature T c EOLS-BI1303-2M-X 0 +70 EOLS-BI1303-2M-X -40 +85 Power Supply Voltage Vcc 3.15 3.3 3.45 V Power Supply Current Icc 360 ma Date Rate 155 Mbps Performance Specifications - Electrical Parameter Symbol Min. Typ. Max Unit Notes Transmitter LVPECL AC coupled Vin 400 2000 mvpp Inputs(Differential) inputs* (Note3) Input Impedance (Differential) TX_Dis Zin 85 100 115 ohm Disable 2 Vcc+0.3 Enable 0 0.8 TX_FAULT Fault Vcc-0.5 Vcc+0.3 Normal 0 0.8 V Receiver LVPECL Outputs (Differential) Vout 400 800 2000 mvpp Output Impedance RX_LOS (Differential) MOD_DEF ( 0:2 ) Zout 85 100 115 ohm LOS 2 Vcc+0.3 V Normal 0 0.8 V VoH 2.5 V VoL 0 0.5 V Performance Specifications Optical V C Rin > 100 kohm @ DC AC coupled outputs* (Note3) With Serial ID (1310nm FP and PIN) Parameter Symbol Min. Typical Max. Unit 50µm Core Diameter MMF(800Mhz*km) L 2 km 62.5 Core Diameter MMF(500Mhz*km) L 1 km Data Rate 155 Mbps Transmitter Center Wavelength λ C 1260 1310 1360 nm Spectral Width (RMS) Δλ 4 nm Average Output Power* (Note4) Pout -20-14 dbm Extinction Ratio* (Note5) ER 9 db Page 3 of 11

Rise/Fall Time(20%~80%) tr/tf 2 ns Total Jitter TJ 1.0 ns Output Optical Eye* (Note5) IUT-T G.957 Compliant* (Note7) TX_Disable Assert Time t_off 10 us TX Disable Asserted - -45 dbm Receiver Center Wavelength λ 1500 1550 1580 nm Receiver Sensitivity* (Note6) Pmin -30 dbm Return Loss 12 db LOS De-Assert LOSD -31 dbm LOS Assert LOSA -45 dbm LOS Hysteresis* (Note8) 1 6 db Overload Pmax -8 dbm (1550nm FP and PIN) Parameter Symbol Min. Typical Max. Unit 50µm Core Diameter MMF(800Mhz*km) L 2 km 62.5 Core Diameter MMF(500Mhz*km) L 1 km Data Rate 125 Mbps Transmitter Center Wavelength λ C 1500 1550 1580 nm Spectral Width (RMS) Δλ 4 nm Average Output Power* (Note4) Pout -20-14 dbm Extinction Ratio* (Note5) ER 9 db Rise/Fall Time(20%~80%) tr/tf 2 ns Total Jitter TJ 1.0 ns Output Optical Eye* (Note5) IUT-T G.957 Compliant* (Note7) TX_Disable Assert Time t_off 10 us TX Disable Asserted - -45 dbm Receiver Center Wavelength λ 1260 1360 nm Receiver Sensitivity* (Note6) Pmin -30 dbm Return Loss 12 db LOS De-Assert LOSD -31 dbm LOS Assert LOSA -45 dbm LOS Hysteresis* (Note8) 1 6 db Overload Pmax -8 dbm Note3: LVPECL logic, internally AC coupled. Note4: Output power is measured by coupling into a 62.5/125 um multi-mode fiber. Note5: Filtered, measured with a PRBS 2 23-1 test pattern @155Mbps. Note6: Minimum average optical power is measured by coupling into a 62.5/125 mm multi-mode fiber; the BER is less than 1E-10, measured with a 2 23-1 PRBS and ER=9 db. Note7: Eye Pattern Mask Note8: LOS Hysteresis Page 4 of 11

SFP Transceiver Electrical Pad Layout Pin Function Definitions Pin Plug Name Function Num. Seq. Notes 1 VeeT Transmitter Ground 1 Note 5 2 TX Fault Transmitter Fault Indication 3 Note 1 3 TX Disable Transmitter Disable 3 Note 2, Module disables on high or open Page 5 of 11

4 MOD-DEF2 Module Definition 2 3 Note 3, Data line for Serial ID. 5 MOD-DEF1 Module Definition 1 3 Note 3, Clock line for Serial ID. 6 MOD-DEF0 Module Definition 0 3 Note 3, Grounded within the module. 7 Rate Select Not Connect 3 Function not available 8 LOS Loss of Signal 3 Note 4 9 VeeR Receiver Ground 1 Note 5 10 VeeR Receiver Ground 1 Note 5 11 VeeR Receiver Ground 1 Note 5 12 RD- Inv. Received Data Out 3 Note 6 13 RD+ Received Data Out 3 Note 7 14 VeeR Receiver Ground 1 Note 5 15 VccR Receiver Power 2 3.3 ± 5%, Note 7 16 VccT Transmitter Power 2 3.3 ± 5%, Note 7 17 VeeT Transmitter Ground 1 Note 5 18 TD+ Transmit Data In 3 Note 8 19 TD- Inv. Transmit Data In 3 Note 8 20 VeeT Transmitter Ground 1 Note 5 Notes: 1) TX Fault is an open collector/drain output, which should be pulled up with a 4.7K 10K2 resistor on the host board. Pull up voltage between 2.0V and VccT, R+0.3V. When high, output indicates a laser fault of some kind. Low indicates normal operation. In the low state, the output will be pulled to < 0.8V. 2) TX disable is an input that is used to shut down the transmitter optical output. It is pulled up within the module with a 4.7 10K2 resistors. Its states are: Low (0 0.8V): Transmitter on (>0.8, < 2.0V): Undefined High (2.0 3.465V): Transmitter Disabled Open: Transmitter Disabled 3) Mod-Def 0,1,2. These are the module definition pins. They should be pulled up with a 4.7K 10K2resistor on the host board. The pull-up voltage shall be VccT or VccR (see Section IV for further details). Mod-Def 0 is grounded by the module to indicate that the module is present Mod-Def 1 is the clock line of two wire serial interface for serial ID Mod-Def 2 is the data line of two wire serial interface for serial ID 4) LOS (Loss of Signal) is an open collector/drain output, which should be pulled up with a 4.7K 10K2 resistor. Pull up voltage between 2.0V and VccT, R+0.3V. When high, this output indicates the received optical power is below the worst-case receiver sensitivity (as defined by the standard in use). Low indicates normal operation. In the low state, the output will be pulled to < 0.8V. Page 6 of 11

5) VeeR and VeeT may be internally connected within the SEP module. 6) RD-/+: These are the differential receiver outputs. They are AC coupled 1002 differential lines which should be terminated with 1002 (differential) at the user SERDES. The AC coupling is done inside the module and is thus not required on the host board. 7) VccR and VccT are the receiver and transmitter power supplies. They are defined as 3.3V ±5% at the SEP connector pin. Maximum supply current is 300mA. Inductors with DC resistance of less than 1 ohm should be used in order to maintain the required voltage at the SEP input pin with 3.3V supply voltage. When the recommended supply-filtering network is used, hot plugging of the SEP transceiver module will result in an inrush current of no more than 30mA greater than the steady state value. VccR and VccT may be internally connected within the SEP transceiver module. 8) TD-/+: These are the differential transmitter inputs. They are AC-coupled, differential lines with 1002 differential termination inside the module. The AC coupling is done inside the module and is thus not required on the host board. EEPROM The serial interface uses the 2-wire serial CMOS EEPROM protocol defined for the ATMEL AT24C02/04 family of components. When the serial protocol is activated, the host generates the serial clock signal (SCL). The positive edge clocks data into those segments of the EEPROM that are not write protected within the SFP transceiver. The negative edge clocks data from the SFP transceiver. The serial data signal (SDA) is bi-directional for serial data transfer. The host uses SDA in conjunction with SCL to mark the start and end of serial protocol activation. The memories are organized as a series of 8-bit data words that can be addressed individually or sequentially. The Module provides diagnostic information about the present operating conditions. The transceiver generates this diagnostic data by digitization of internal analog signals. Calibration and alarm/warning threshold data is written during device manufacture. Received power monitoring, transmitted power monitoring, bias current monitoring, supply voltage monitoring and temperature monitoring all are implemented. If the module is defined as external calibrated, the diagnostic data are raw A/D values and must be converted to real world units using calibration constants stored in EEPROM locations 56 95 at wire serial bus address A2H. The digital diagnostic memory map specific data field define as following.for detail EEPROM information, please refer to the related document of SFF 8472 Rev 9.3. Page 7 of 11

Recommend Circuit Schematic Page 8 of 11

Mechanical Specifications SC Connector LC Connector *This 2D drawing only for reference, please check with Eoptolink before ordering. Page 9 of 11

Laser Emission Obtaining Document You can visit our website: http://www.eoptolink.com Or contact listed at the end of the documentation to get the latest documents. Revision History Revision Initiated Reviewed Approved Revision History V2.a Jacky. Cheng Release Date Philo.Chen Released. July 14, 2009 V2.b Kelly Update the mechanical spec. Jan 23, 2010 V2.c Kelly Add LC ordering info. Apr 26, 2010 V3.a V3.b Phlio Phlio Update logo Update Mechanical and Recommend Circuit. Remove EEPROM Detail Information Change Power Link Budget Aug 10, 2011 Aug 22, 2011 V3.c Kelly Update photo. Nov 4, 2011 V3.d V3.e V3.f Angela, Avrin,Jan s Angela/ Daquan, Dong Angela Kelly/lyn Kelly/Vina/ Walt/Jason /Lyn V3.g Angela Kelly/Vina Angela Kelly/Vina/ Dean Phlio Phlio Adjusted format and deleted Class 1 label &laser emission date Update regulatory compliance and Max. Pout Update the distance, regulatory compliance, LOSD&LOSA and mechanical spec. Update the tolerances of mechanical spec. Update ordinary information, regulatory compliance and the tolerances of 2D drawing. Feb 27,2013 Dec 2,2013 Feb 11,2015 April 09,2015 June 15,2016 Page 10 of 11

Notice: Eoptolink reserves the right to make changes to or discontinue any optical link product or service identified in this publication, without notice, in order to improve design and/or performance. Applications that are described herein for any of the optical link products are for illustrative purposes only. Eoptolink makes no representation or warranty that such applications will be suitable for the specified use without further testing or modification. Contact: Add: Floor 5, Building 2, No. 21 Gaopeng Avenue, High-Tech District, CHENGDU, SICHUAN 610041 P.R. CHINA Tel: (+86) 028-85122709 ext 816 & 809 Fax: (+86) 028-85121912 Postal: 610041 E-mail:sales@eoptolink.com http://www.eoptolink.com Page 11 of 11