RAY MC COMPACT ENERGY METER MECHANICAL

Similar documents
RAY MC COMPACT ENERGY METER MECHANICAL

RAY COMPACT ENERGY METER MECHANICAL

RAY MECHANICAL COMPACT METER. 4 MID approved class 2 from ND 15 mm qp 0,6 m3/h up to ND 40 mm qp 10 m3/h

SHARKY 775 ULTRASONIC COMPACT METER. 4 Approval with dynamic range up to 1:250 (qi:qp) MID in class 2 (depends on meter size), standard 1:100

SHARKY 775 ULTRASONIC COMPACT METER. 4 Approved according EN 1434 and MID in class 2 with dynamic range of 1:250 (qi:qp) in class 2

WESAN WP E ELECTRONIC METER WOLTMAN

SHARKY 775 ULTRASONIC COMPACT METER. 4 Approved according EN 1434 and MID in class 2 with dynamic range of 1:250 (qi:qp) in class 2

Brunata Optuna H. Properties. Counter

SONOMETER TM 1100 Ultrasonic compact energy meter

EW447-EW452 Series Mechanical Heatmeters FOR HEATING AND COOLING APPLICATIONS

SONOMETER TM 1100 Ultrasonic compact energy meter

INFOCAL 8 Energy calculator

SonoMeter 31 Energy Meters

Infocal 9 Energy calculator

SonoSelect 10 and SonoSafe 10 Energy Meters

SONO 1500 CT Ultrasonic flow sensor

SONOMETER TM 1000 Ultrasonic compact heat meter

ULTRASONIC D. Compact ultrasonic heat meter

Heat meter Q heat 5 US

MULTICAL 302 DATA SHEET

SVM F27 / C27. Ultrasonic BTU meter for heating or cooling. Data sheet

SVM F27 Compact. Ultrasonic heatmeter. Data sheet

Portfolio. and ULTRAWATER. Ultrasonic Static Meters. Ultrasonic Meters Residential and District Heating/ Cooling Water Measurement

Q water 5.5. Electronic water meter. Data sheet DST1-QWA5-EN0 WMEAP / V 2.1

Electronic Heating Energy Meters

SONOMETER 2000 Ultrasonic heat meter

Supercal 531 Multi function Integrator that lives up to Your highest expectations

HDU-SF (Horizontal Distribution Units - Single Flat)

Brunata Optuna H Ultrasonic energy meter Type 775 Installation Guide Edition 1.2

MULTICAL Energy meter TS PTB. Application

Siemens Switzerland Ltd HVAC Products. SIEMECA Electronic Heat and Cooling Meters

ultego III smart plus

MULTICAL 403. Data sheet

Smart Mobile Metering Solutions WALK-BY OR DRIVE-BY READING HYDRUS SMART METERS AND IZAR SYSTEM COMPONENTS

The innovative way forward symphonic sensor net radio system

USB Meter Reader. Data sheet. For reading Kamstrup consumption meters

MULTICAL 601 DATA SHEET

SVM F22. Calculator for heating or cooling applications. Data sheet

MULTICAL 603. Data sheet. The future-proof heat and cooling meter with full flexibility

Energy Meters for DIN Rail Mounting Electric energy meter WS0101, WS0102,WS1102 WS0301, WS0302,WS1302

Tentative. Rectifier Module VARIS R-400-H. Tentative VARIS -R

ULTRAHEAT T230 ULTRACOLD T230

Metering systems 0527EN January 2014 Sanitary water meter, GE552-2 series Versions for wireless centralisation

Annex to application for conformity assessment of Heat meters in accordance with MID

12/2 Product overview. 12/3 7KT1 14, 7KT1 53 E-counters. 12/9 7KT1 11, 7KT1 12 digital measuring devices. 12/11 7KT1 0 analog measuring devices

MULTICAL 403. Data sheet

ULTRAHEAT / ULTRACOLD T330. The Evolutionary. Ultrasonic Heat Meter / Cooling Meter. Ultrasonic Heat Meter / Cooling Meter.

MULTICAL 603. Data sheet. The future-proof heat and cooling meter with full flexibility

microclima Single Jet SENSOSTAR 2/2+ DE-07-MI004-PTB025 (MID, heat)

ULTRAHEAT / ULTRACOLD T330. The Evolutionary. Ultrasonic Heat Meter / Cooling Meter. Ultrasonic Heat Meter / Cooling Meter.

RISH EM 3490 SS Kilowatt Hour Energy Meter With Rs485 RISH EM 3490 SS. Application : Product Features: Indication: Pulse Indication:

Datasheet (Preliminary) Modular Inverter System VARIS Datasheet VARIS

Express Delivery. Axial. Connection

Installation and Operating Instructions Compact Heat Meter Compact Heat / Cooling Meter Amtron

Instruction. INFOCAL 8 Energy calculator. 1.0 Table of contents. 2.0 Safety notes and product information

Technical Description MULTICAL 302. Kamstrup A/S Industrivej 28, Stilling DK-8660 Skanderborg T: kamstrup.

Applications. Features RESIDENTIAL ULTRASONIC WATER METER. Revenue metering Residential submetering Commercial buildings.

Online data sheet VT12T-2P410 V12-2 CYLINDRICAL PHOTOELECTRIC SENSORS

Miniature resistance thermometer Model TR33, thread-mounted

Applications. Features RESIDENTIAL ULTRASONIC WATER METER. Revenue metering Residential submetering Commercial buildings.

Yonos PARA RS **/7.0 ipwm1 Datasheet

flowiq 3100 Data sheet

Data Sheet. RISH Master Record %THD

MHPS MHPS. Modular pressure transmitter. Technical documentation. Table of content. Characteristics - applications - technical data

( F L O W I Z F A M I L Y )

Datasheet. Modular Inverter System VARIS Datasheet VARIS

ULTRAFLOW. Application. Cooling flow sensor. Ultrasonic flow sensor. Compact design. Static meter with no moving parts. Large dynamic range.

RISH Master Digital Multifunction Instrument with onsite pluggable output options. Application : Product Features:

JUMO Wtrans E01. Measuring probe for humidity, temperature, and CO 2 with wireless data transmission. Brief description. Universal Wtrans receiver

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

Fluke 1740 Series. Three-Phase Power Quality Loggers Memobox. Assess power quality and conduct long-term studies with ease

Absolute Encoders Multiturn

Resistance thermometer Model TR30, compact design

FLOW RATE CORRECTION CALCULATOR GDR 1403

1 2 3 GridVis Pulse output 2 tariffs Modbus MID M-Bus

TMU. Coriolis Mass Flow Meter. for liquids and gas

Online data sheet DFS60B-S4PA00S74 DFS60 INCREMENTAL ENCODERS

ATM.ECO - Analog Pressure Transmitter with Temperature Compensation

Online data sheet WT260-R260 W260 PRODUCT PORTFOLIO

WATERFLUX 3070 Technical Datasheet

SITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview

Ultrasonic heat and cooling energy meters

Instruction. SONOMETER 1100 Ultrasonic compact energy meter. 1.0 Table of contents. 2.0 Safety notes and product information

DS 400 DS 400. Intelligent Electronic Pressure Switch Completely in Stainless Steel. piezoresistive stainless steel sensor

Power quality Harmonics up to 40th harmonic Unbalance, rotary field indication Distortion factor THD-U / THD-I

Distance Sensors BOD 26K.... with optional Master-Slave-Mode

Flow Switch - 2 programmable thresholds. Stand Alone (Battery) - Battery powered, - 2 totalizers display, - Local flow display,

SN+ MID MASTER + APPLICATION WATER METERS

Current Clamp. 210

Online data sheet VTF18-4N1212 V18 CYLINDRICAL PHOTOELECTRIC SENSORS

Pressure Transmitter SIL

This data sheet is only valid in association with the IL SYS INST UM E user manual.

PHOTOELECTRIC SENSORS. Online data sheet

Nubis propeller water meter with horizontal impeller axle

Resistance thermometer Model TR31, miniature design

SITRANS F flowmeters SITRANS F US SONOCAL /184 Siemens FI

MULTICAL 602 DATA SHEET

Technical Data Sheet. x1000. kwh R Y B

Design and applications

Specifications. 744 Users Manual

Transcription:

APPLICATION Fully electronic measuring capsule heat meter, heat and cooling meter or cooling meter with impeller scanning for volume measuring and energy calculation. Highly accurate recording of all billing data in a heating circuit or a cooling / heating circuit at medium temperatures from 5 C up to 90 C. FEATURES 4 Electronic sensor control for recording flow rate 4 Lithium battery, lifetime up to 12 years 4 Optical ZVEI interface equipped as standard 4 Adjustable reading date for billing 4 Rotatable integrator 4 Single-line 7-digit display for easy meter reading 4 Can be installed in housings from the Diehl Metering range of accessories or in housings with a 2" coupling thread already available in the network

COMPONENTS Multi-jet volume measuring component (DN 15-20) Calculator, contains hardware and software for measuring flow rate, temperature and energy consumption Temperature sensor permanently connected in integrator CALCULATOR - BASIC FEATURES Ambient class EN 1434 class C / MID E1 + M1 Protection class DIN 40050 / IEC-EN 60529 IP 54 (heat meter) IP 65 with potted calculator (combined heat-cooling / cooling meter) Interfaces standard Optical ZVEI according IEC 870-5 Interfaces optional M-Bus, radio, pulse Note: IZAR@SET / HYDRO-SET Software for configuration of meters, reading of measured values and printout of meter logs. Available under www.diehl.com/metering (Products - Downloads) DISPLAY Display indication LCD, 7-digit Unit MWh - kwh - GJ - MJ - kw - m³/h - l/h - m³ - l Total values 9,999,999-999,999.9-99,999.99-9,999.999 Values displayed Power - energy - flow rate - temperature - energy on reading date - reading date TEMPERATURE INPUT Temperature sensor type Pt 500 / 2-wire Measuring cycle T s 32 Max. temperature difference ΔΘ K +102 Min. temperature difference ΔΘ K +3 Starting temperature difference ΔΘ K +0.25 Absolute temperature measurement range Θ C 0... 105 SUPPLY VOLTAGE Operating voltage U N V DC 3.0 (lithium battery) Battery lifetime Up to 12 years Nominal power P N μw 30 INTERFACES - OVERVIEW Optical ZVEI interface for communication, M-Bus protocol M-Bus According to EN 1434-3. Data reading and parametrization are via two wires with polarity reversal protection. (Meter is powered with energy via M-Bus Master) Radio 868 MHz, Real Data or Open Metering Standard (OMS) protocol Pulse Output for heat meters or cooling meters (energy / volume), for cooling-heat meters (energy cooling / energy heating or energy cooling / total volume), for heat-cooling meters (energy heating / energy cooling or energy heating / total volume) 14.08.2015 2

RADIO INTERFACE - SPECIFICATION Frequency MHz 868 Protocol Real Data (according EN 13757) or Open Metering Standard (OMS) Transmission power mw 10 Transmission interval sec. 64 Communication Via Bluetooth optohead and IZAR@SET / HYDRO-SET software or IZAR@MOBILE software VOLUME- / ENERGY PULSE Output type Open collector Max. frequency Hz 4 Max. input voltage V 30 Max. input current ma 100 Max. voltage drop at active output V/mA 2/27 Max. current through inactive output μa/v 5/30 Max. reverse voltage without destroying outputs V 6 Min. pulse duration ms 125 Min. pulse break ms 125 14.08.2015 3

GENERAL Temperature range C 5... 90 Ambient operating temperature C 0... 55 Ambient storage temperature C -20... 55 Nominal pressure PN bar 16 Temperature sensor type Pt 500 with 2 wire leads Cable length of temperature sensor 0.4 m mounted in measuring capsule; 1.5 m free Mounting position energy meter In any position, also up side down Approval MID (DE-07-MI004-PTB030) and PTB TR K7.2 (22.72 / 09.04) for cooling meter TEMPERATURE SENSOR Tangential sensor* - - - Type 1 0.4 m Ø 5.2 mm PU grey 3 K - 102 K Free sensor - - - Type 1 1.5 m Ø 5.2 mm PU grey 3 K - 102 K Type 2 1.5 m Ø 5 mm PU grey 3 K - 102 K * mounted in measuring capsule TECHNICAL DATA Nominal diameter DN mm 15 15 20 Nominal flow rate q p m³/h 0.6 1.5 2.5 Maximum flow rate q s m³/h 1.2 3 5 Minimum flow rate at ΔΘ 3 K q i l/h 120 120 120 Minimum flow rate* q i l/h 6 15 25 Starting flow rate l/h 1.5-2 3-4 5-6 Pressure loss at q p Δp mbar 243 243 242 Flow rate at 0.1 bar pressure loss m³/h 0.385 0.962 1.607 Flow resistance coefficient Zeta 56.25 9 10.24 * according to EN1434 for flow sensor 14.08.2015 4

DIMENSIONS Capsule Nominal diameter DN mm 15 15 20 Nominal flow rate q p m³/h 0.6 1.5 2.5 Connection interface Ø A Inch G2B G2B G2B Height H mm 15.2 15.2 15.2 Height H1 mm 55 55 55 Diameter Ø B mm 63 63 63 Diameter Ø C mm 74 74 74 Weight kg 0.5 0.5 0.5 DIMENSIONS - ACCESSORY Housing Nominal diameter DN mm 15 15 20 Nominal flow rate q p m³/h 0.6 1.5 2.5 Overall length L mm 110 110 130 Overall length with coupling L2 mm 190 190 210 Height H mm 17 17 21 Height H1 mm 29 29 31 Order no. 1 piece 3031602 3031602 3031600 Order no. 6 pieces 3026961 3026961 3029251 14.08.2015 5

PRESSURE LOSS GRAPH / TYPICAL ERROR GRAPH Pressure loss graph Typical error graph 14.08.2015 6