SMARTLINE RM 70. Non-contact Radar (FMCW) Level Meter for liquids. Supplementary instructions

Similar documents
OPTIWAVE 5200 C/F Quick Start

OPTIWAVE 7300 C Supplementary instructions

SmartLine Non-Contact Radar Level Meter Technical Datasheet. Specification. The Universal Radar Solution. Highlights. Industries.

OPTIWAVE 7300 C Handbook

OPTIWAVE 1010 Technical Datasheet

OPTIWAVE 7300 C Technical Datasheet

Foundation Fieldbus Control in the Field (CIF)

LST100 Ultrasonic level transmitter for upstream oil and gas

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

RMA42. Technical Information

OPTIWAVE 7300 C Handbook

OPTIWAVE 5200 C/F Technical Datasheet

WIRELESS MODBUS GATEWAY WGW410

SITRANS L Level instruments

Engineering Guideline. pac-carriers Type for Yokogawa Centum VP

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

Field Devices and Wiring

Instruction Manual ABM HART Gateway Software. Instruction Manual Revision A.1

Isolators A3/1.

Operating manual for the electronic transmitter UMC3-FF with Foundation-Fieldbus interface

Model R86 26 GHz Pulse Burst Radar Level Transmitter

Trip amplifier, 1 channel

Installation guide 873 SmartRadar Control Unit & Antenna Unit

Free-Space Radar Level Meter

FOSTEN AUTOMATION SÉRIE F500-RD

Technical Information Proline Prowirl R 200

SMARTPAT COND 1200 Technical Datasheet

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

BATCHMATE 1500 Batch Control Computer Technical Bulletin

Technical Information Barrier RB223

General Specifications

OPTIWAVE 6300 C Quick Start

OPTISONIC Ultrasonic flowmeter for liquids in all industrial applications

Automation 2013 Mumbai 2013 Fieldbus Foundation

SITRANS F flowmeters SITRANS F US. Transmitter FUS060. Overview

COMMUNICATION NETWORKS

Level Measurement. Continuous level measurement - Radar transmitters SITRANS LR400 5/229. Overview

3 Ex i Isolators. Temperature Transmitter without Output 0/ ma, with Limit Value Contact (Field Circuit Ex i) Type 9182/.

Level Measurement. Continuous level measurement - Radar transmitters SITRANS LR400 5/229. Overview

Installation guide 970, 971 and 973 series SmartRadar

Analog Universal Module HART for Zone 2 Series 9468/33

3 Ex i Isolators. Temperature Transmitter with Output 0/ ma, without Limit Value Contact (Field Circuit Ex i) Type 9182/.0-5.

Technical Information RMA42

Electro-Magnetic Flowmeters COPA-XE

itemp PA TMT184 Technical information

Installation guide 970 SmartRadar ATi

TS16 - Pre-Instructional Survey

Digital I/O Coupler (4-wire) Series 9413/21

SMARTLINE LEVEL SLG700

Technical Information Proline Prowirl D 200

Transmitters BROCHURE

Isolators A3/1. Temperature Transmitter Field Circuit Non-Ex i Series

Fieldbus Foundation India Committee & ISA South India Section

Rosemount 8700 Series. Magnetic Flowmeter Systems. Rosemount 8700 Series. Product Data Sheet , Rev TA April 2009.

Installation guide 971 SmartRadar LTi

Worldwide Manufacturer of Gas Detection Solutions. Transmitter EC 23. Operation Manual

JUPITER 200. Magnetostrictive Level Transmitter. Worldwide level and flow solutions. Measures «LEVEL» and «INTERFACE» D E S C R I P T I O N

2600T Series Pressure Transmitter Model 264DS Differential Pressure Transmitter. Kent-Taylor

Technical Information Proline Prowirl F 200

Installation guide 854 XTG Level Gauge

DT1100 xx xx xx PS. Isolators, Isolator / Power Supplies. Operating Instructions

Isolators A3/1.

Technical Information Proline Prowirl F 200

GROUP 29 FOUNDATION FIELDBUS SUPPLEMENT

DC Voltage Hawk II H235 Series Advanced Digital Panel Meter

Data Sheet KFD2-UFC-EX1.D. Supplied by. .com. Call us on +44 (0)

Conductivity +/ 2% 1 or 2 point remotely through PLC or directly on board. Any two lead Conductivity probe (K 0.01, K 0.1, K 1.

TEK-TROL HART GATEWAY SOFTWARE. Operating Instruction Manual.

Multimeter 500CVD21 RTU500 series

PROFIBUS HUB REPEATER

Mastr III P25 Base Station Transmitter Tune-up Procedure

AT200 Magnetostrictive Level Transmitter. External mounted magnetostrictive level transmitter K-TEK Products

Signal converter for electromagnetic flowmeters

Ultrasonic level meters ULM 70

RS-485 HUB GT for Profibus, Sinec L2, Bitbus, etc. Article No S-485-HUBGT-230-xx-x. Operation and Installation Manual

Calibrating Fieldbus Transmitters??? - Yes, it is easy!

Radio System Strobe Wizard Plus Freemask

Modulating control valve

SLG 700 SmartLine Level Transmitter Guided Wave Radar FOUNDATION TM Fieldbus Option Manual

Assembly. Front view. HiC2441. SL2 1b. Termination Board

Thank you for buying this AIS antenna splitter.

TMU. Coriolis Mass Flow Meter. for liquids and gas

Head mounted Temperature Transmitter TF02/TF02-Ex

Safety Instructions Proline Promass 300

REFLEX RADAR INDICATOR

THE PROBE, 5 METER, 2WIRE, LOOP POWERED SINGLE POINT LEVEL MEASUREMENT SYSTEM (ULTRASONIC)

MFC 400 Technical Datasheet

Installation guide 877 FDI Field Display & Interface

RHE11. Hazardous Area Multifunction Coriolis Flow Transmitter. Features. Applications. Benefits

Tank Gauging System with FOUNDATION Fieldbus

MFC 400 Technical Datasheet

OPTITEMP TT 20 Technical Datasheet

DT1100 E xx xx (PS) Galvanic Isolators. Operating Instructions

Advanced Guided Wave Radar Transmitter for Level Measurement and Control

2-wire level transmitter

HAWK Magnetostrictive Level Transmitter (CSA/FM, ATEX)

Transit Time Ultrasonic Flow Measuring System PROline prosonic flow 93 P

937CU-AITXF-DC1 Installation Instructions. Transmitter Supply Converter

Multi-Variable Analog Interface for Smart Transmitters Specifications

Fieldbus Foundation India Committee. Fieldbus Foundation Asset Management and Diagnosis Automation-2010, India

Transcription:

SMARTLINE RM 70 Supplementary instructions Non-contact Radar (FMCW) Level Meter for liquids Supplementary Instructions for FOUNDATION Fieldbus communication

CONTENTS 1 General safety information 3 1.1 Scope of the document... 3 1.2 Device description... 3 1.3 Scope of delivery... 3 2 FOUNDATION Fieldbus data 5 3 Electrical connections 7 3.1 Electrical installation: terminals... 7 3.2 Electrical connection: PACTware... 8 4 Operation 9 4.1 Description of device data... 9 4.1.1 Resource block... 9 4.1.2 Transducer block... 9 4.1.3 Measurement data... 10 4.1.4 Status data... 10 5 Operation 11 2

GENERAL SAFETY INFORMATION 1 1.1 Scope of the document These instructions are applicable only to the radar level transmitter with the FOUNDATION Fieldbus communication option. For all other data, use the Quick Start and other chapters of the Handbook. If you do not have these documents, please contact the nearest office or download them from the manufacturer's internet site. INFORMATION! The information in this chapter only contains the data applicable to FOUNDATION Fieldbus communication. The technical data in the Handbook shall be valid in its current version, provided that it is not rendered invalid or replaced by this supplement. 1.2 Device description This device is a 4-wire level transmitter that uses FMCW (Frequency-Modulated Continuous Wave) radar technology.it measures level, volume, distance to surface, and reflectivity of liquids, pastes and slurries. It is suitable for installation on storage tanks, process tanks and stilling wells. Measurements are displayed via a DTM (device type manager) for remote communication or on an optional integrated display screen with wizard-driven setup and online help functions. The level transmitter is approved for use in potentially explosive atmospheres when equipped with the appropriate options. 1.3 Scope of delivery The information in this chapter only contains the data applicable to FOUNDATION Fieldbus communication. The technical data in the Handbook shall be valid in its current version, provided that it is not rendered invalid or replaced by this supplement. A device for FOUNDATION Fieldbus communication is supplied with Supplementary Instructions for FOUNDATION Fieldbus communication Device description (DD) and capability (CCF) files on a CD-ROM supplied with the device 3

1 GENERAL SAFETY INFORMATION 4

FOUNDATION FIELDBUS DATA 2 INFORMATION! The data that follows is applicable only for fieldbus communication networks. For general data, refer to the handbook. Additional information (certificates, special tools, software, files...) and complete product documentation is on the CD delivered with the device or can be downloaded free of charge from the website. Description Type Output signal Test status FMCW radar level transmitter Digital signal that agrees with the FF communication protocol Registered Data blocks Registered features Alarms, events, function blocks, linking and trending Registered function blocks 1 x Resource Block (RB) 4 x Analog Input Blocks (RB) Other blocks 1 x Transducer Block (TB) Communication Standard Foundation Fieldbus protocol that agrees with IEC 61158-2 ITK version 5.1 Physical layer Protocol Physical layer types Other features Foundation Fieldbus protocol that agrees with IEC 61158-2, galvanically isolated Standard power signaling, bus powered, non I.S. Bus interface with integrated reverse polarity protection Electrical connections Device power supply (24 V input) Current consumption on FOUNDATION Fieldbus network 18...30 VDC 20 ma Input and output Output data Input data Error current FDE Link Master function Level, distance, level conversion, level mass, reflection, ullage conversion or distance mass None Typically 0 ma (FDE =Fault Disconnection Electronic) Not supported 5

2 FOUNDATION FIELDBUS DATA 6

ELECTRICAL CONNECTIONS 3 3.1 Electrical installation: terminals Electrical connection must agree with IEC 61158-2. Figure 3-1: Electrical installation 1 Terminal compartment cover 2 Power supply terminal: 24 VDC - 3 Power supply terminal: 24 VDC + 4 Grounding terminal in the housing 5 Communication terminal: - 6 Communication terminal: + 7 Grounding terminal between the process connection and the converter INFORMATION! The FF terminal is connected to a Fieldbus Power Hub. The 24 VDC terminal energizes the device. Procedure: Remove the housing terminal compartment cover 1. Connect the FF segment to the communication terminals 5 and 6 of the device. Obey the national electrical codes and fieldbus specifications for communication networks. Make sure that the polarity of the wires is correct. Connect the power supply to the power supply terminals 2 and 3 of the device. Obey the national electrical codes. Make sure that the polarity of the wires is correct. Attach the ground to 4 or 7. Both terminals are technically equivalent. 7

3 ELECTRICAL CONNECTIONS 3.2 Electrical connection: PACTware CAUTION! Before you use PACTware to configure the device, disconnect the device from the FOUNDATION Fieldbus segment. CAUTION! The HART address of the device must be set to "1". If the device is not set to "1", the device will not operate in FOUNDATION Fieldbus networks. Refer to the Handbook for more data on how to change the HART address. PACTware is an Open Source, open configuration software for all field devices. Use PACTware to configure your device. For more data, refer to "Start-up" in the handbook. Attach a HART converter to the terminals shown in the illustration that follows. We recommend the VIATOR converter that is available as an accessory for this device. Refer to the Handbook for more data on accessories. Figure 3-2: Electrical connection: PACTware 1 PACTware terminals 8

OPERATION 4 4.1 Description of device data 4.1.1 Resource block The Resource Block supplies data about the device for operation in the FOUNDATION Fieldbus network. Its operation mode also has an effect on the data supplied by the device. The Resource Block has these operation modes: Automatic (Auto), and Out of Service (OOS) In Automatic mode, all resources (including Transducer and Function blocks) can operate correctly. In the Out of Service mode, all blocks are in Out of Service mode and no measurement and status data is supplied to the network. The blocks cannot change their mode until the Resource block is set again to Automatic mode. If a block is in Out of Service mode, this is shown in its BLOCK_ERR parameter. 4.1.2 Transducer block The parameter MODE_BLK controls the mode set in the Transducer Block. The Transducer Block has these modes: Automatic (Auto), Manual (MAN), and Out of Service (OOS) In Automatic mode, the Transducer operates correctly and supplies measurement values and status (PRIM_VAL_TYPE_0 to PRIM_VAL_TYPE_6). The Transducer Block has a special error parameter XD_ERROR. If this parameter displays the error Electronics failure, it is possible that the device will not operate correctly. If the Transducer Block status does not change, please contact the local support desk of your supplier. 9

4 OPERATION 4.1.3 Measurement data Use a master and the DD - CFF files to configure the device for the network. Set the measurement values (modules) that are regularly transmitted to the master device. The table that follows gives a list of measurement data (each value has a status) that is available in this sequence. Measurement data Foundation Fieldbus Variable Measurement variable Unit 4.1.4 Status data PRIM_VAL_TYPE_0 Level Meter PRIM_VAL_TYPE_1 Distance Meter PRIM_VAL_TYPE_2 Level Conversion 1 Cubic meter PRIM_VAL_TYPE_3 Level Mass 1 Ton (metric) PRIM_VAL_TYPE_4 Reflection % PRIM_VAL_TYPE_5 Ullage Conversion 1 Cubic meter PRIM_VAL_TYPE_6 Distance Mass 1 Ton (metric) 1 if there is no conversion table, this measurement is not available. The message "Not_a Number (non signalling) is transmitted. The status is set to "Bad-Out of Service". CAUTION! Monitor the status of the device. The device transmits a measurement value when the device status is "good", "uncertain" or "bad". The status will tell you if the device measures correctly. 10

OPERATION 4 11

Honeywell Field Solutions 512 Virgina Drive Fort Washington, PA 19034 Honeywell International Inc. Subject to change without notice.