MPQ1000. Handheld Power Quality Analyzer. Automatic CT recognition. Automatic connection verification. On-board data analysis

Similar documents
Power Quality Testing

Fluke 1750 Three-Phase Power Recorder

Fluke Three-Phase Power Recorder. Plug and play: Set up in minutes with selfidentifying

Fluke Fluke-Direct.ca. Three-Phase Power Logger. Technical Data

Fluke Advanced Test Equipment Rentals ATEC (2832) Three-Phase Power Recorder

Fluke Three-Phase Power Recorder. Never miss capturing a disturbance - with the exclusive threshold-free measurement system, it s automatic.

Fluke Three-Phase Power Quality Recorder Topas. Class-A compliance for the most demanding power quality tests

Network Analyzer for Low-, Medium- and High-Voltage Networks

DM-5 Power Quality Analyzer

Energy Explorer PROFESSIONAL POWER & HARMONICS ANALYSER

C.A 8332 C.A Advanced Test Equipment Rentals ATEC (2832) Display your network analysis all in picture format!

Choosing the Right PowerSight Model

C.A 8332 C.A Display your network analysis all in picture format! OBSERVE, DIAGNOSE, MONITOR... Three Phase Power Quality Analysers

Maximum power. Nominal voltage. Operating temperature 0 to 50ºC. Humidity without condensation 5 95 % Contamination level 2 Current input features

Pinpoint power quality problems faster

Fluke 345. Power Quality Clamp Meter. The ideal meter for commissioning and troubleshooting modern electrical loads

Fluke 1736 and 1738 Three-Phase Power Loggers

PQ-Box 100 Network Analyzer for Low-, Medium- and High-Voltage Networks

3196 POWER QUALITY ANALYZER. Solve All Your Power Quality Problems ISO14001 JQA-E Power Measuring Instruments

Choosing the Right PowerSight Model. No matter what your needs or budget there is probably a PowerSight model that is right for you

Choosing the Right PowerSight Model. Comparison Table between PowerSight models**

PQM3000R Class A network analyzer according to EN for power quality monitoring

With any other power quality analyzer you re just wasting energy.

UNIVERSAL MEASURING INSTRUMENTS. TNM 34xx. TNM 3410 / 3420 / 3430 / 3440 Universal measuring instrument 1/49

RISH PQM. Power Quality Monitor. Preliminary Datasheet subject to change without notice. Individual Harmonics measurement upto 56th Harmonics

Pinpoint power quality problems faster

Advantages There are many diverse advantages of a portable analyzer for the user. The most important is information.

Maximum power. Nominal voltage. Operating temperature 0 to 50ºC. Humidity without condensation 5 95 % Contamination level 2 Current input features

Network Analyzer for Low-, Medium- and High-Voltage Networks

MICROPROCESSOR-BASED METERING EQUIPMENT SECTION 16901C PART 2

An Introduction to Power Quality

Power Quality Analyzer / High Frequency Recorder

The experience of the Qualistar ensuring high performance

Power Quality Recorders with Wireless Communications

MVCT. Megger VT & CT Analyzer. MVCT Megger VT & CT Analyzer

Power supply circuit Through an external power supply unit V ac / 12 V dc. Operating temperature ºC. Humidity of operation

C.A Complete electrical network analysis at the tips of your fingers! Power Quality Monitor. Keeping up with the standards

PQube 3 Firmware 3.5.0

The experience of the Qualistar, ensuring high performance

METRAClip87 and 88 Clamp Multimeters

E6000 E6000. Handheld Power Quality Analyzer. Features. Functions

Elgar SmartWave Series VA V A. High Performance AC/DC Power Source. and Boeing standards

Complimentary Reference Material

Data Sheet. RISH Master Record %THD

E6500 Power Quality Analyzer

PQube 3 Specifications

Fluke 1740 Series. Three-Phase Power Quality Loggers Memobox. Assess power quality and conduct long-term studies with ease

MEASURING INSTRUMENTS AND TESTERS

Fluke 3540 FC Three-Phase Power Monitor

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.

Network Analyzer for Low-, Medium- and High-Voltage Networks

Fluke 3540 FC Three-Phase Power Monitor

POWER QUALITY ANALYZER NP40 USER S MANUAL

Current Clamp. 210

ELITE PRO. Automation Components, Inc.

DM-III Multitest & DM-III Multitest F Power Quality Recorders

RISH Master Digital Multifunction Instrument with onsite pluggable output options. Application : Product Features:

1742, 1746 and 1748 Three-Phase Power Quality Loggers

Digital Multifunction Instrument - Rish Master 3440

RISH EM 3490 DS Dual Source Energy Meter (With All Display Parameters) RISH EM 3490 DS. Application : Product Features:

Programmable AC Power Source Model 9801

Power Quality Analysers

Power Quality Analyzer Topas 2000

Application Alpha 20 Measures important electrical parameters in 3 phase 4 Wire and 3 phase 3 Wire Network & replaces the multiple analog panel meters

1742, 1746 and 1748 Three-Phase Power Quality Loggers

ALPHA 50 MULTIFUNCTION METER (ALPHA SERIES)

The series allows users to compose. amplify the analog signal from arbitrary signal generator. Thus, it is capable of simulating the

Technical Data Sheet AMIK 300 / 301

ALPHA 20 MULTIFUNCTION METER (ALPHA SERIES)

Dranetz-BMI : the award-winning hand-held 3-phase power analyzer

TOSHIBA International Corp

Applications Avionics Testing Power Line Simulation Production Test - Power Supplies - UPS - Telecom. SMARTWAVE Programmable AC/DC Power Source

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.

1 In This Document Elspec

ODEN AT Primary Current Injection Test System

Welcome to the rd. Annual Northern Ohio. 3 rd Energy Management Conference September 30, 2008

Power Meter PQM (EnerSure Enkapsis) Guide Form Specification PART 1: GENERAL

Advanced Test Equipment Rentals ATEC (2832)

HV / MV / LV electrical network quality analyzers Class A. Communication port: local, modem, integrated Ethernet, multi-point

Fluke 1740 Series. Three-Phase Power Quality Loggers Memobox. Assess power quality and conduct long-term studies with ease

PROGRAMMABLE AC POWER SOURCE MODEL 6500 SERIES MODEL 6500 SERIES. Programmable AC Power Source. Key Features:

Fluke 1732 and 1734 Three-Phase Electrical Energy Loggers

Fluke 430 Series II Three-Phase Power Quality and Energy Analyzers

METRAClip85 and 86 Clamp Multimeters

Fluke 430 Series Three-Phase Power Quality Analyzers

PA9 Wireless Power Quality Analyzer

DRTS 66 The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

PQA823 PQA824 Rel /09/18

TORKEL 900-series Battery Load Unit

Metering Devices, Protective Relays, Software and Connectivity

Arbitrary/Function Generator AFG1000 Series Datasheet

OPERATING MANUAL POWER QUALITY ANALYZER PQM-707

DM-III MULTITEST Power Quality Recorder

PQM3000 Class A rack 19 power quality analyzer for CTs or current clamps

PA3000 Four-channel, Multi-phase AC/DC Power Analyzer

MT 560/UMT TRANSDUCER & ANALYZER

Jewell DPM Power / Power Factor Size 96/96 BEST IN CLASS

Advanced Test Equipment Rentals ATEC (2832)

5-kV and 10-kV Insulation Resistance Testers. n CAT IV 600 V safety rating. n Line supply or battery operated

2-channel models. 4-channel models

Transcription:

Automatic CT recognition Automatic connection verification On-board data analysis SD card and USB stick support 1000 V ac and 1000 V dc range Scope and DMM modes CATIV @ 600 V IEC61000-4-30 Class A compliant DESCRIPTION The Megger Power Quality Analyzer is an advanced handheld 3-phase analyzer. It is a highly intuitive analyzer that delivers unmatched capability in a smart ergonomic platform. View RMS data, waveforms, demand data, phase angles, harmonics, unbalance, flicker and more in real time with the scope mode and DVM mode. When data needs to be recorded the record verification will automatically identify the current clamps, recognize their range and verify the unit is connected properly. Simply connect it and push the record button. The can record for extended periods of time because of its massive memory. It utilizes an SD card, which makes expanding the memory as easy as installing a new SD card. The recorded data can be viewed on the color VGA display or the data can be transferred to the high power Megger PQ Power Quality Analysis software via USB cable, USB stick, Ethernet or directly from the SD card. MEASURED PARAMETERS RMS voltage / current Total harmonic distortion DC voltage DC current (requires dc CT) Phase-to-phase voltage Power parameters (KW, KVAR, KVA, DPF, TPF) Total demand distortion Harmonics Inter-harmonics Energy parameters (KWH, KVARH, KVAH) Voltage sag/dips and swells Mains signaling Phase angles Harmonic direction Current sags/dips and swells IEC flicker Transient down to 1 msec Rapid voltage change IEC unbalance Phase angle deviation Frequency ANSII unbalance Event waveform capture Timed waveform capture FEATURES AND BENEFITS Automatic CT recognition means never having the unit programmed for an incorrect range. CTs are powered by the unit so there is no need for additional connections or batteries. Connection verification ensures the unit is configured correctly and you get the data you need no wasted recordings. On-board data analysis saves time by allowing an immediate examination of data before leaving the site. Multiple communication methods (USB, Ethernet, USB stick or SD card) allow for flexible and convenient operation. Removable SD card allows for large recording capabilities and simple memory expansion. The expanded 1000 V ac range allows for more application; no need for a second unit. 1000 V dc measurement allows testing and analysis of renewable applications dismissing the need for additional equipment. CATIV @ 600 V assures a safe unit for all applications. Full-featured Class A compliant (all parameters) ensures the recording of correct values. Smart configuration in the Megger PQ software for quick and easy setup. Phase angle stability measurement lets you easily find tricky phasing problems caused by multiple erratic sources. Timed waveform capture allows for the taking of PQ events and periodic waveforms at the same time. Easy intuitive menus allow for simple navigation and operation. Free software included means no license or dongle required.

APPLICATIONS Using experience gained from supplying a multitude of analyzers to a large number of utilities, industries and service providers, Megger has designed the most versatile unit available today. Some of the applications include the following: Compliance testing to any PQ standard Power factor studies Load studies and load balancing Billing verification Substation monitoring Capacitor bank sizing Transformer analysis and de-rating Motor troubleshooting and inrush testing Switchgear and component failure Tripping breakers Equipment tripping offline Dimming/surging lighting Lamp flicker analysis Neutral overheating Solar (PV) analysis SPECIFICATIONS Input Power 120/240 V, 50/60 Hz International power adapter supports US, UK, EU and Australian plugs Battery NiMH battery pack (field replaceable) Discharge time up to 8 hours Recharge time 3 hours Data storage External SD card (32GB max) Communication USB communications Ethernet communications: network communications. Wireless communications with off-the-shelf bridge. USB stick - transfer data file to USB. Transfer setup configurations to and from USB stick. Perform firmware upgrades using USB stick. SD card: automatically writes data to SD card; no manual transfer required. Transfer setup configurations to and from SD card. No tool needed to access the SD card. Environmental Operating: -20 C to 50 C (-4 F to 122 F) Storage: -30 C to 60 C (-22 F to +140 F) Relative humidity: 0-95% non-condensing Altitude <2000 m: 1000V CAT III / 600 V CAT IV Altitude 2000 m - 5000 m: 600 V CAT III / 300 V CAT IV Case IP54 enclosure Kensington lock Display Backlit 11.5 cm x 8.5 cm color VGA Resolution 5.56 pixels per mm (640 x 480 pixels, 115.2 x 86.4 mm) Refresh rate: 1-3 sec PQ Events Dips / sags: Triggers off of voltage and current. IEC61000-4-30 compliant. Swells: Triggers off of voltage and current. IEC61000-4-30 Compliant Sub-cycle distortions: Triggers off of voltage and current. IEC61000-4- 30 compliant. Transient detection: 1 μsecond. Triggers off of first 3 voltage channels. IEC61000-4-30 compliant. THD: Triggers off of voltage and current. IEC61000-4-30 Compliant Rapid Voltage Change (RVC): Triggers off of first 3 voltage channels. IEC61000-4-30 compliant. Phase shifts: Trigger event when a phase shift occurs between the voltage channels. Record date and time, duration and waveforms of all enabled channels. Phase shift user selectable down to 1 degree. Waveform capture of events: Capture waveforms on all enabled channels when an out of limits event occurs. Waveforms programmable with up to 9 pre-trigger cycles and 99 post-trigger cycles. Timed waveform capture: Captures waveforms periodically on all enabled channels. Waveform capture interval programmable down to 1 cycle. Programmable number of cycles to be captured up to 99 cycles. Event triggered waveforms and timed triggered waveforms simultaneously. Mains signaling events: Two selectable frequencies and amplitudes. Selectable time interval. Measured per IEC61000-4-30. Captures waveforms on all enabled channels when a mains signaling event occurs. Waveform programmable with up to 9 pre-trigger cycles and 99 post-trigger cycles. Event Flagging: Measured per IEC61000-4-30. Motor Inrush Records RMS, Power and PF at a 1 cycle resolution. Capture inrush current during motor start up. Support both three-phase and single-phase motors. Real Time Data Scope Mode: View waveforms in scope mode Freeze, zoom and pan View Vector scope View ANSI unbalance View IEC unbalance View harmonic in real time View inter-harmonics in real time View RMS voltage and current in real time DMM Mode: View IEC unbalance View Harmonic in real time View RMS voltage and current in real time View THD in real time View active power in real time View reactive power in real time View apparent power in real time View DPF in real time View TPF in real time View flicker in real time

Compliance IEC61000-4-7 IEC61000-4-30 (Class A) IEC61000-4-15 IEC61000-4-27 IEC61010-1 IEC61326 IEC60529 MIL-STD-810-G IEEE1453 CAN/CSA-C22.2 No. 1010.1-92 RoHS2 Directive 2011/65/EU IEEE1459 Dimensions 269 mm x 178.4 mm x 70.7 mm (10.6 in. x 7.0 in. x 2.8 in.) Weight Standard unit: 1.82 kg (4 lbs) Sampling Resolution: 16 bit analog to digital converter on 8 channels Max sampling speed: 1 MHz max Max RMS sampling: 17,664 per channel max PLL synchronization: 42.5 Hz to 69 Hz Real Time Clock Accuracy ±20 ppm Trended Parameters Voltage 4 voltage channels Voltage range: 0 to 1000 V range AC RMS DC Measures AC & DC simultaneously (common neutral required) Voltage accuracy: 0.1% per IEC61000-4-30 Voltage ratios: Adjustable voltage ratios for measuring secondaries. (.0001 through 9999) Resolution: 16 bit Crest factor: 1.5 Max pk voltage: 1628 V / 2500 V Voltage lead set: 5 voltage leads, 6 ft (2 m) in length. Safety banana leads. Removable alligator clips. Optional plunger clips. Set of color bands for customizing color codes. Safety green/yellow ground lead included. Fused adapter: In line with voltage leads to provide fuse protection (optional). Current Channels 4 current channels Current range: 0 to 6000 A (CT dependent) Current ratios: Adjustable current ratios for measuring secondaries (000.1 through 9999) Current accuracy: ±0.5% of reading ±0.05% of full scale Resolution: 16 bit Crest factor: 4.0 Power and Energy Active power (KW): Per IEEE1459 Reactive power (KVAR): Per IEEE1459 Apparent power (KVA): Per IEEE1459 Energy parameters (KWH, KVARH, KVAH): Per IEEE1459 Displacement power factor range: -1.0 to +1.0 Displacement power factor accuracy: = ±0.02 + CT error True power factor range: 0.0 to +1.0 True power factor accuracy: = ±0.02 + CT error Power configurations: 11 Aggregation window: 1 cycle to 1 hour - fixed and sliding windows Unbalance: ANSI & IEC methodology per IEC61000-4-27 Total Harmonic Distortion (THD): Per IEC61000-4-30 per IEC61000-4-7 Harmonics: 0 through 50th continuous Inter-harmonics: 0 through 50th continuous Total Demand Distortion (TDD): Per IEEE519 Frequency: Per IEC61000-4-30 Flicker: Per IEC61000-4-15 Functions Auto identify CT and CT range setting Configuration verification - Display if unit is connected incorrectly. On board analysis - Perform data analysis on unit. Compare recorded values against customizable templates. Waveform analysis through the 128th order. Clock hour orientation - Time sync recording to nearest interval. Scheduled run - Select start and stop time of recording. Instrument then automatically begins recording. On board configuration - Ability to configure recording parameters from front panel of instrument. Auto Setup - Ability to have instrument automatically configure itself. On board naming of data and setup files -Ability to name data and setup files from the front panel of the instrument. Supported languages: English, Spanish, French, German & Czech On Board Instrument Preference Settings: Selectable Traces Colors Selectable Short Cut Buttons Selectable Time Out Period Chart Grid ON / OFF Measurement Parameters RMS voltage

RMS current Sags / dips / swells Transients (1 msec) (±2697 V) Sub-cycle events 64 msec (notching, noise) Rapid voltage change Phase angle stability IEC Unbalance ANSII Unbalance Power (KW, KVAR, KVA, DPF & TPF) Energy (KWH, KVARH & KVAH) Power Factor (1 to 0 to -1) Phase Angle THD/TDD Harmonics Inter-Harmonics Power Harmonics Harmonic Direction Flicker Waveform Capture Frequency Software Windows compliant (Win 7, Win 8 and Win 10) See MPQ Analysis Software datasheet for details ACCESSORIES Instrument strap (P/N 2009-205) Two-piece strap for hanging instrument from both metallic and nonmetallic structures. One piece is attached to the instrument; the other piece wraps around any structure, then they clip together. Power Quality Simulator (P/N MPQ-SIM-01) An ideal training tool. Creates a three-phase source, 50/60 Hz and loads off of single-phase dc adapter. n Create dips and swells on voltage and current channels n Create transients n Create phase shifts between voltage channels n Create phase shifts between voltage channels and current channels n Create harmonics n Create flicker n Create power reversals

OPTIONAL ACCESSORIES CP-1000WCE-ID 1000 A split core CT CP-100CE-ID 100 A split core CT Split Core Current Clamp 1000 A (CP-1000WCE-ID) Split Core Current Clamp Available options: 100 A (CP-100CE-ID) 20 A (CP-100CE-ID) 5 A (CP-5CE-ID) CP-20CE-ID CP-5CD-ID CP-600DC-ID 20 A split core CT 5 A split core CT 600 A split core AC/DC current clamp MCCV Rain Tight Flexible Current Clamps These flexible rain tight CTs have four current ranges that are all self-identifying. The current clamps are powered from the Analyzer and come in three different diameters (18 cm, 27 cm, and 37 cm). Ranges include 60 A, 600 A, 3000 A and 6000 A. Hall Effect Current Clamp 600 A dc and 400 A ac (CP-600DC-ID) Voltage Lead Set Standard set of voltage leads included with. Includes: 5 voltage leads and 1 ground lead. Range = 0 to 1000 V ac/dc Multiple colar straps. Configure your voltage leads for the required color code. MCCV Rain Tight Flexible Current Clamps Available diameters: 18 cm (MCCV6000-18) 27 cm (MCCV6000-27) 37 cm (MCCV6000-37) CAT IV @ 600 V 1008-645 Optional Fuse Adapter Kit This adapter connects to the standard leads. Includes 4 adapters with multiple color straps. Optional Fuse Adapter Kit (1008-645) Voltage Lead Set (2007-259) Optional Plunger Clips (1008-756)

ACCESSORY KITS Basic Kit C/N -BASIC Includes analyzer, voltage leads, SD card, USB cable, ethernet cable, universal power adapter, soft-sided carry bag plus fuse adapters and hanging strap. Does not include current clamps. Gold Kit C/N -G-KIT Includes analyzer, voltage leads, SD card, USB cable, hanging strap, voltage lead plunger clips, and 3 MCCV6000-27 (four range flex 27 cm ID) CTs Silver Kit C/N -S-KIT Includes analyzer, voltage leads, SD card, USB cable, hanging strap, voltage lead plunger clips, and 3 MCCV6000-18 (four range flex 18 cm ID) CTs Gold Plus Kit C/N -G-KIT-PLUS Includes analyzer, voltage leads, SD card, USB cable, hanging strap, voltage lead plunger clips, and 4 MCCV6000-27 (four range flex 27 cm ID) CTs Silver Plus Kit C/N -S-KIT-PLUS Includes analyzer, voltage leads, SD card, USB cable, hanging strap, voltage lead plunger clips, and 4 MCCV6000-18 (four range flex 18 cm ID) CTs

SPLIT CORE CURRENT CLAMP KITS Kit of 4 split core self ID 1000A PQ CT C/N CP-1000WCE-ID-KIT Split core current clamp for the MPQ and PA9 series. Self-identifying on MPQ. Supports 1000A range. 6 in. (1.82 m) cord. Kit of 4 split core self ID 100A PQ CT C/N CP-100CE-ID-KIT Platinum Kit C/N -P-KIT Includes analyzer, voltage leads, SD card, USB cable, hanging strap, voltage lead plunger clips, and 3 MCCV6000-37 (four range flex 37 cm ID) CTs Split core current clamp for the MPQ and PA9 series. Self-identifying on MPQ. Supports 100A range. 6 in. (1.82 m) cord. Kit of 4 split core self ID 20A PQ CT C/N CP-20CE-ID-KIT Split core current clamp for the MPQ and PA9 series. Self-identifying on MPQ. Supports 20A range. 6 in. (1.82 m) cord. Kit of 4 split core self ID 5A PQ CT C/N CP-5CE-ID-KIT Split core current clamp for the MPQ and PA9 series. Self-identifying on MPQ. Supports 5A range. 6 in. (1.82 m) cord. Kit of 3 split core self ID 600A (AC/DC) PQ CT C/N CP-600DC-ID-KIT Hall effect current clamp for the MPQ and PA9 series. Self-identifying on MPQ. Supports 600A dc and 400A ac range. 6 in. (1.82 m) cord. Platinum Plus Kit C/N -P-KIT-PLUS Includes analyzer, voltage leads, SD card, USB cable, hanging strap, voltage lead plunger clips, and 4 MCCV6000-37 (four range flex 37 cm ID) CTs

ORDERING INFORMATION Item (Qty) 8 channel 3-phase power quality analyzer * basic kit * silver kit * silver plus kit * gold kit * gold plus kit * platinum kit * platinum plus kit Cat. No. -BASIC -S-KIT -S-KIT-PLUS -G-KIT -G-KIT-PLUS -P-KIT -P-KIT-PLUS *See description of Kit contents on previous pages Included Accessories Unfused voltage lead kit 2007-259 32 GB SD card 90023-619 USB memory stick: contains MPQ user 1009-697 guide, Megger PQ PC software and Megger PQ PC software user guide USB communications cable CA-USB Ethernet communications cable 36798 Soft sided case 2007-626-1 Universal 24 Vdc power adapter 90011-992 Battery pack 2008-369 Item (Qty) Optional Accessories Cat. No. Fused adapter kit (3 adapters and fuses) 1008-645 Kit of 4 plunger clips 1008-756 Instrument strap 2009-205 Power quality simulator Current Clamps Four range 6000 A AC rain tight, self-identifying, flexible rope current clamps (18 cm ID) Four range 6000 A AC rain tight, self-identifying, flexible rope current clamps (27 cm ID) Four range 6000 A AC rain tight, self-identifying, flexible rope current clamps (37 cm ID) 1000 A AC split core current, selfidentifying current clamps (50 mm ID) 100 A AC split core current, selfidentifying current clamps (20 mm ID) 20 A AC split core current, selfidentifying current clamps (20 mm ID) 5 A AC split core current self-identifying current clamps (20 mm ID) AC/DC 600 A split core current selfidentifying current clamps (50 mm ID) **Kit of 4 split core self ID 1000A PQ CT MPQ-SIM-01 MCCV6000-18 MCCV6000-27 MCCV6000-37 CP-1000WCE-ID CP-100CE-ID CP-20CE-ID CP-5CE-ID CP-600DC-ID CP-1000WCE-ID-KIT NOTE: The above Kits are available in the US and Canadian distribution markets only. **Kit of 4 split core self ID 100A PQ CT **Kit of 4 split core self ID 20A PQ CT **Kit of 4 split core self ID 5A PQ CT **Kit of 3 split core self ID 600A (AC/DC) PQ CT **See description of Kit contents on previous pages CP-100CE-ID-KIT CP-20CE-ID-KIT CP-5CE-ID-KIT CP-600DC-ID-KIT SALES OFFICE Megger 2621 Van Buren Avenue Norristown, PA 19403 USA T 866-254-0962 E VFCustomerSupport@megger.com _DS_US_V04 www.megger.com ISO 9001:2008 The word Megger is a registered trademark Specifications are subject to change without notice