WindPRO version joulu 2012 Printed/Page :22 / 1. DECIBEL - Main Result

Similar documents
WindPRO version Sep 2011 Printed/Page :22 / 1. DECIBEL - Main Result. Calculation: Bielice Park. WTGs. Sound Level.

WindPRO version Sep 2011 Printed/Page :29 / 1. DECIBEL - Main Result. Calculation: Bielice Park. WTGs. Sound Level.

WindPRO version Sep 2011 Project:

Description: Valmistaja takaa mallinnuksessa käytetyn melun kokonaistason. Valmistajan takuu ei koske oktaavi- tai tessioktaavikaistoja.

Field noise measurement in the huge industrial plants for accurate prediction

WIND TURBINE ACOUSTICS - a sneak preview on research topics- Dr. Andree Altmikus ENERCON Research & Development

Investigation of Noise Spectrum Characteristics for an Evaluation of Railway Noise Barriers

Pre-Construction Sound Study. Velco Jay Substation DRAFT. January 2011 D A T A AN AL Y S IS S OL U T I ON S

METHODOLOGY FOR VERIFICATION OF SOFTWARE FOR NOISE ATTENUATION CALCULATION ACCORDING TO ISO STANDARD

Environmental Noise Propagation

IS INTERNATIONAL STANDARD. Acoustics - Attenuation of sound during propagation outdoors - Part 2: General method of calculation

Please refer to the figure on the following page which shows the relationship between sound fields.

ECMA-108. Measurement of Highfrequency. emitted by Information Technology and Telecommunications Equipment. 4 th Edition / December 2008

APPENDIX A SOUND PROPAGATION THEORY & METHODOLOGIES

ECMA-108. Measurement of Highfrequency. emitted by Information Technology and Telecommunications Equipment. 5 th Edition / December 2010

Acoustic Assessment Report Silvercreek Solar Park Transformer Station Aylmer, Ontario

Problems with the INM: Part 2 Atmospheric Attenuation

Acoustic Calibration Service in Automobile Field at NIM, China

Appendix D: Preliminary Noise Evaluation

The SoundPLAN Expert System for Industry Noise

Reducing the influence of microphone errors on in- situ ground impedance measurements

Silent Transformers to Help Consolidated Edison Meet New York City s Ultrastrict Noise Ordinances

SILVERSTONE CIRCUIT MASTERPLAN APPENDIX H NOISE & VIBRATION

PREDICTING SOUND LEVELS BEHIND BUILDINGS - HOW MANY REFLECTIONS SHOULD I USE? Apex Acoustics Ltd, Gateshead, UK

FINAL REPORT. On Project Supplemental Guidance on the Application of FHWA s Traffic Noise Model (TNM) APPENDIX K Parallel Barriers

RECOMMENDATION ITU-R P Attenuation by atmospheric gases

UC Berkeley Northside Relocation Cellular Facility

Atmospheric Effects. Attenuation by Atmospheric Gases. Atmospheric Effects Page 1

REVISED NOISE IMPACT STUDY

HARMONOISE: NOISE PREDICTIONS AND THE NEW EUROPEAN HARMONISED PREDICTION MODEL

NOISE ASSESSMENT REPORT Fairview Wind Project Township of Clearview (Stayner), Ontario

Contact person Date Reference Page Joachim Stadig P (7) Building Technology

Supporting Network Planning Tools II

Chapter 4. Propagation effects. Slides for Wireless Communications Edfors, Molisch, Tufvesson

Template Planning Condition on Amplitude Modulation Noise Guidance Notes

A comparing overview on ECAC Doc.29 3 rd Edition and the new German AzB

The Influence of Quieter Pavement & Absorptive Barriers on US 101 in Marin County

Semi Anechoic Chamber (SAC)

Pipeline Blowdown Noise Levels

RECOMMENDATION ITU-R F.1404*

Assured Monitoring Group

ACOUSTIC BARRIER FOR TRANSFORMER NOISE. Ruisen Ming. SVT Engineering Consultants, Leederville, WA 6007, Australia

Lecture 7: Superposition and Fourier Theorem

Noise Monitoring Report For. Schloetter (Ireland) Ltd. Naas Enterprise Park, Naas, Co. Kildare

APPENDIX K NAPIER PORT WHARF NO. 6 FUTURE PORT NOISE MAPS

A Method for Estimating Noise from Full-Scale Distributed Exhaust Nozzles

HIIUMAA OFFSHORE WINDFARM, ESTONIA LOW FREQUENCY NOISE AND INFRASOUND SURVEY

noise is generally defined as unwanted sound

Performance of Roadside Sound Barriers with Sound Absorbing Edges

Small craft -Measurement of sound pressure level of airborne sound emitted by powered recreational craft

BASELINE NOISE MONITORING SURVEY

SOURCE DIRECTIVITY INFLUENCE ON MEASUREMENTS OF SPEECH PRIVACY IN OPEN PLAN AREAS Gunilla Sundin 1, Pierre Chigot 2.

Measuring procedures for the environmental parameters: Acoustic comfort

Noise Abatement Design Study Report Dulles Loop Project (Route 606 and Loudoun County Parkway) UPC 97529

DESIGN OF VOICE ALARM SYSTEMS FOR TRAFFIC TUNNELS: OPTIMISATION OF SPEECH INTELLIGIBILITY

EFFECTS OF BLADDERED FISH ON AMBIENT NOISE MEASUREMENTS CLOSE TO THE PORT OF ROTTERDAM

Noise Mitigation Study Pilot Program Summary Report Contract No

DOT-VNTSC-FAA Edward J. Rickley Joyce E. Rosenbaum Gregg G. Fleming Christopher J. Roof Eric R. Boeker

Parallel Barrier Effects for Distant Receivers

Chapter 3 Signal Degradation in Optical Fibers


Tones in HVAC Systems (Update from 2006 Seminar, Quebec City) Jerry G. Lilly, P.E. JGL Acoustics, Inc. Issaquah, WA

Exercise 3-2. Effects of Attenuation on the VSWR EXERCISE OBJECTIVES

SW Series Impedance Tube Solutions

Boggabri Coal Mine. Environmental Noise Monitoring October Prepared for Boggabri Coal Operations Pty Ltd

580 - NOISE BARRIERS OPSS 580 INDEX

Comparison of impulse noise measurements and calculations by noise prediction methods: ISO , NMPB- 2008, Nord2000 and Harmonoise

Study of the Performance of Acoustic Barriers for Indiana Toll Roads

PRELIMINARY STUDY ON THE SPEECH PRIVACY PERFORMANCE OF THE FABPOD

Signals, Sound, and Sensation

Bancroft & Piedmont Cellular Facility

The influences of changes in international standards on performance qualification and design of anechoic and hemi-anechoic chambers

Measuring Instrument Combinations

An experimental evaluation of a new approach to aircraft noise modelling

Outlook on Candidate Performance Specifications for QRTV

Liddell Coal Operations

The Harmonoise noise prediction algorithm: Validation and use under Australian conditions

Technical Note. Noise reducing properties of crash barriers. Performed for WillumTech. AV 1217/11 Project no.: A Page 1 of 19 incl.

Monopile as Part of Aeroelastic Wind Turbine Simulation Code

Technical support in the implementation of the Environmental noise directive 2002/49/EU

Acoustics Technical Note

Technical Data Measurement Microphones

Fourier Analysis. Chapter Introduction Distortion Harmonic Distortion

Attenuation by atmospheric gases

Liddell Coal Operations

Model LF2500 Low Frequency Sound Silencer

Appendix 8. Draft Post Construction Noise Monitoring Protocol

Black. LWECS Site Permit. Stearns County. Permit Section:

ODEON APPLICATION NOTE ISO Open plan offices Part 2 Measurements

Temperature and Water Vapor Density Effects On Weather Satellite

LWA Beamforming Design Concept

Ashton Coal. Environmental Noise Monitoring May Prepared for Ashton Coal Operations Pty Ltd

SOUND PROPAGATION OUTDOORS. T.F.W. Embleton, J.E. Piercy, N. Olson Division of Physics, National Research Council Ottawa, Ontario K1A 0S1

OneSteel Recycling Hexham Quarterly Noise Monitoring Report Q2 2017

Active noise control at a moving virtual microphone using the SOTDF moving virtual sensing method

Electricity Supply to Africa and Developing Economies. Challenges and opportunities. Planning for the future in uncertain times

APPENDIX M NOISE ANALYSIS

Acoustics Research Group

CHAPTER 3 THE DESIGN OF TRANSMISSION LOSS SUITE AND EXPERIMENTAL DETAILS

Muswellbrook Coal Company

Transcription:

13.6.2013 19:22 / 1 DECIBEL - Main Result Calculation: Alue 2 ( 9 x HH120 GF=0,5, 105,5 db) TuuliSaimaa kaavaluonnos Noise calculation model: ISO 9613-2 General Wind speed: 8,0 m/s Ground attenuation: General, Ground factor: 0,5 Meteorological coefficient, C0: 0,0 db Type of demand in calculation: 1: noise is compared to demand (DK, DE, SE, NL etc.) Noise values in calculation: All noise values are mean values (Lwa) (Normal) Pure tones: Pure and Impulse tone penalty are added to source noise Height above ground level, when no value in NSA object: 1,5 m Don't allow override of model height with height from NSA object Deviation from "official" noise demands. Negative is more restrictive, positive is less restrictive.: 0,0 db(a) s New Scale 1:75 000 Noise sensitive area Finish GK KKJ (3 deg)-kkj (FI 1992 <±5m) Zone: 3 type Noise data East North Z Row data/description Valid Manufact. Type-generator Power, Rotor Hub Creator Name Wind Status LwA,ref Pure rated diameter height speed tones [m] [kw] [m] [m] [m/s] [db(a)] 1 3 482 978 6 705 738 9,2 Yes 3 000 110,0 120,0 USER Runtime input 8,0 User value 105,5 0 db h 2 3 483 531 6 705 937 22,5 Yes 3 000 110,0 120,0 USER Runtime input 8,0 User value 105,5 0 db h 3 3 483 229 6 706 483 17,5 Yes 3 000 110,0 120,0 USER Runtime input 8,0 User value 105,5 0 db h 4 3 482 884 6 706 960 14,1 Yes 3 000 110,0 120,0 USER Runtime input 8,0 User value 105,5 0 db h 5 3 483 433 6 707 197 20,8 Yes 3 000 110,0 120,0 USER Runtime input 8,0 User value 105,5 0 db h 6 3 482 982 6 707 344 19,1 Yes 3 000 110,0 120,0 USER Runtime input 8,0 User value 105,5 0 db h 7 3 482 390 6 707 325 18,7 Yes 3 000 110,0 120,0 USER Runtime input 8,0 User value 105,5 0 db h 8 3 482 330 6 707 837 15,0 Yes 3 000 110,0 120,0 USER Runtime input 8,0 User value 105,5 0 db h 9 3 483 030 6 707 754 20,0 Yes 3 000 110,0 120,0 USER Runtime input 8,0 User value 105,5 0 db h h) Generic octave distribution used Calculation Results Sound Level Noise sensitive area Finish GK KKJ (3 deg)-kkj (FI 1992 <±5m) Zone: Demands 3 Sound Level Demands fulfilled? No. Name East North Z Imission height Noise From s Noise [m] [m] [db(a)] [db(a)] A Asuinrakennus (Seppälä) 3 483 765 6 705 288 12,2 1,5 40,0 38,2 Yes B Asuinrakennus 3 484 013 6 705 381 10,0 1,5 40,0 37,3 Yes C Asuinrakennus (Mäkelä) 3 484 867 6 705 843 7,5 1,5 40,0 32,7 Yes D Asuinrakennus (Metsola) 3 484 867 6 706 000 9,8 1,5 40,0 33,0 Yes E Asuinrakennus 3 484 507 6 706 184 5,0 1,5 40,0 35,7 Yes F Lomarakennus 3 484 783 6 706 255 11,2 1,5 40,0 33,8 Yes G Asuinrakennus (Majanders) 3 484 111 6 707 601 14,1 1,5 40,0 38,1 Yes H Asuinrakennus (Simosäng) 3 483 947 6 707 625 10,0 1,5 40,0 39,6 Yes I Asuinrakennus (Peltola) 3 481 444 6 706 612 7,5 1,5 40,0 35,1 Yes J Asuinrakennus (Hilsvida) 3 481 902 6 706 013 8,6 1,5 40,0 36,1 Yes K Asuinrakennus (Mysskärri) 3 482 240 6 705 239 7,5 1,5 40,0 35,6 Yes L Lomarakennus 3 482 012 6 704 937 7,5 1,5 40,0 32,7 Yes M Lomarakennus (Källarbottnen) 3 481 223 6 703 831 19,1 1,5 35,0 25,9 Yes N Lomarakennus 3 483 374 6 704 025 27,8 1,5 40,0 29,7 Yes Distances (m) NSA 1 2 3 4 5 6 7 8 9 A 905 690 1309 1889 1937 2199 2457 2924 2572 B 1094 735 1352 1940 1905 2216 2531 2975 2567 C 1891 1339 1758 2275 1972 2408 2886 3226 2650 D 1906 1338 1708 2202 1867 2314 2808 3131 2539 To be continued on next page...

13.6.2013 19:22 / 2 DECIBEL - Main Result Calculation: Alue 2 ( 9 x HH120 GF=0,5, 105,5 db) TuuliSaimaa kaavaluonnos...continued from previous page NSA 1 2 3 4 5 6 7 8 9 E 1592 1007 1313 1798 1476 1915 2404 2732 2155 F 1877 1292 1571 2025 1646 2103 2620 2918 2306 G 2180 1762 1424 1383 789 1157 1742 1796 1092 H 2120 1737 1349 1253 669 1004 1585 1630 926 I 1765 2192 1789 1482 2072 1703 1185 1512 1954 J 1111 1630 1407 1365 1935 1714 1400 1873 2074 K 891 1467 1588 1837 2291 2231 2090 2598 2635 L 1255 1818 1967 2203 2669 2595 2417 2916 2995 M 2590 3123 3323 3541 4024 3927 3682 4154 4317 N 1758 1918 2461 2975 3172 3341 3443 3951 3744

DECIBEL - Detailed results 13.6.2013 19:22 / 3 Assumptions Calculated L(DW) = LWA,ref + K + Dc - (Adiv + Aatm + Agr + Abar + Amisc) - Cmet (when calculated with ground attenuation, then Dc = Domega) LWA,ref: Sound pressure level at K: Pure tone Dc: Directivity correction Adiv: the attenuation due to geometrical divergence Aatm: the attenuation due to atmospheric absorption Agr: the attenuation due to ground effect Abar: the attenuation due to a barrier Amisc: the attenuation due to miscellaneous other effects Cmet: Meteorological correction Calculation Results Noise sensitive area: A Asuinrakennus (Seppälä) 1 905 913 32,34 105,5 0,00 70,21 - - 0,00 0,00-0,00 2 690 702 35,21 105,5 0,00 67,92 - - 0,00 0,00-0,00 3 1 309 1 315 28,21 105,5 0,00 73,38 - - 0,00 0,00-0,00 4 1 889 1 893 23,90 105,5 0,00 76,54 - - 0,00 0,00-0,00 5 1 937 1 941 23,60 105,5 0,00 76,76 - - 0,00 0,00-0,00 6 2 199 2 202 22,05 105,5 0,00 77,86 - - 0,00 0,00-0,00 7 2 457 2 460 20,67 105,5 0,00 78,82 - - 0,00 0,00-0,00 8 2 924 2 926 18,46 105,5 0,00 80,33 - - 0,00 0,00-0,00 9 2 572 2 576 20,09 105,5 0,00 79,22 - - 0,00 0,00-0,00 Sum 38,21 Noise sensitive area: B Asuinrakennus 1 1 094 1 100 30,25 105,5 0,00 71,83 - - 0,00 0,00-0,00 2 735 747 34,53 105,5 0,00 68,47 - - 0,00 0,00-0,00 3 1 352 1 357 27,84 105,5 0,00 73,65 - - 0,00 0,00-0,00 4 1 940 1 944 23,58 105,5 0,00 76,77 - - 0,00 0,00-0,00 5 1 905 1 910 23,80 105,5 0,00 76,62 - - 0,00 0,00-0,00 6 2 216 2 219 21,95 105,5 0,00 77,92 - - 0,00 0,00-0,00 7 2 531 2 534 20,29 105,5 0,00 79,08 - - 0,00 0,00-0,00 8 2 975 2 978 18,23 105,5 0,00 80,48 - - 0,00 0,00-0,00 9 2 567 2 571 20,11 105,5 0,00 79,20 - - 0,00 0,00-0,00 Sum 37,33 Noise sensitive area: C Asuinrakennus (Mäkelä) 1 1 891 1 895 23,89 105,5 0,00 76,55 - - 0,00 0,00-0,00 2 1 339 1 346 27,94 105,5 0,00 73,58 - - 0,00 0,00-0,00 3 1 758 1 763 24,76 105,5 0,00 75,93 - - 0,00 0,00-0,00 4 2 275 2 279 21,62 105,5 0,00 78,15 - - 0,00 0,00-0,00 5 1 972 1 976 23,38 105,5 0,00 76,92 - - 0,00 0,00-0,00 6 2 408 2 412 20,91 105,5 0,00 78,65 - - 0,00 0,00-0,00 7 2 886 2 888 18,63 105,5 0,00 80,21 - - 0,00 0,00-0,00 To be continued on next page...

DECIBEL - Detailed results 13.6.2013 19:22 / 4...continued from previous page 8 3 226 3 228 17,19 105,5 0,00 81,18 - - 0,00 0,00-0,00 9 2 650 2 654 19,71 105,5 0,00 79,48 - - 0,00 0,00-0,00 Sum 32,72 Noise sensitive area: D Asuinrakennus (Metsola) 1 1 906 1 910 23,80 105,5 0,00 76,62 - - 0,00 0,00-0,00 2 1 338 1 344 27,96 105,5 0,00 73,57 - - 0,00 0,00-0,00 3 1 708 1 712 25,11 105,5 0,00 75,67 - - 0,00 0,00-0,00 4 2 202 2 206 22,03 105,5 0,00 77,87 - - 0,00 0,00-0,00 5 1 867 1 872 24,04 105,5 0,00 76,45 - - 0,00 0,00-0,00 6 2 314 2 317 21,41 105,5 0,00 78,30 - - 0,00 0,00-0,00 7 2 808 2 811 18,97 105,5 0,00 79,98 - - 0,00 0,00-0,00 8 3 131 3 133 17,58 105,5 0,00 80,92 - - 0,00 0,00-0,00 9 2 539 2 543 20,25 105,5 0,00 79,11 - - 0,00 0,00-0,00 Sum 32,97 Noise sensitive area: E Asuinrakennus 1 1 592 1 596 25,94 105,5 0,00 75,06 - - 0,00 0,00-0,00 2 1 007 1 016 31,15 105,5 0,00 71,14 - - 0,00 0,00-0,00 3 1 313 1 319 28,18 105,5 0,00 73,41 - - 0,00 0,00-0,00 4 1 798 1 803 24,49 105,5 0,00 76,12 - - 0,00 0,00-0,00 5 1 476 1 482 26,82 105,5 0,00 74,42 - - 0,00 0,00-0,00 6 1 915 1 920 23,73 105,5 0,00 76,66 - - 0,00 0,00-0,00 7 2 404 2 408 20,94 105,5 0,00 78,63 - - 0,00 0,00-0,00 8 2 732 2 735 19,32 105,5 0,00 79,74 - - 0,00 0,00-0,00 9 2 155 2 159 22,29 105,5 0,00 77,69 - - 0,00 0,00-0,00 Sum 35,72 Noise sensitive area: F Lomarakennus 1 1 877 1 880 23,98 105,5 0,00 76,48 - - 0,00 0,00-0,00 2 1 292 1 298 28,36 105,5 0,00 73,27 - - 0,00 0,00-0,00 3 1 571 1 576 26,10 105,5 0,00 74,95 - - 0,00 0,00-0,00 4 2 025 2 028 23,06 105,5 0,00 77,14 - - 0,00 0,00-0,00 5 1 646 1 651 25,55 105,5 0,00 75,35 - - 0,00 0,00-0,00 6 2 103 2 107 22,59 105,5 0,00 77,47 - - 0,00 0,00-0,00 7 2 620 2 623 19,85 105,5 0,00 79,38 - - 0,00 0,00-0,00 8 2 918 2 920 18,48 105,5 0,00 80,31 - - 0,00 0,00-0,00 9 2 306 2 310 21,46 105,5 0,00 78,27 - - 0,00 0,00-0,00 Sum 33,79

DECIBEL - Detailed results 13.6.2013 19:22 / 5 Noise sensitive area: G Asuinrakennus (Majanders) 1 2 180 2 183 22,16 105,5 0,00 77,78 - - 0,00 0,00-0,00 2 1 762 1 766 24,74 105,5 0,00 75,94 - - 0,00 0,00-0,00 3 1 424 1 429 27,24 105,5 0,00 74,10 - - 0,00 0,00-0,00 4 1 383 1 389 27,58 105,5 0,00 73,85 - - 0,00 0,00-0,00 5 789 799 33,80 105,5 0,00 69,05 - - 0,00 0,00-0,00 6 1 157 1 164 29,61 105,5 0,00 72,32 - - 0,00 0,00-0,00 7 1 742 1 747 24,87 105,5 0,00 75,84 - - 0,00 0,00-0,00 8 1 796 1 800 24,51 105,5 0,00 76,10 - - 0,00 0,00-0,00 9 1 092 1 099 30,26 105,5 0,00 71,82 - - 0,00 0,00-0,00 Sum 38,15 Noise sensitive area: H Asuinrakennus (Simosäng) 1 2 120 2 123 22,50 105,5 0,00 77,54 - - 0,00 0,00-0,00 2 1 737 1 742 24,90 105,5 0,00 75,82 - - 0,00 0,00-0,00 3 1 349 1 354 27,87 105,5 0,00 73,63 - - 0,00 0,00-0,00 4 1 253 1 259 28,72 105,5 0,00 73,00 - - 0,00 0,00-0,00 5 669 681 35,53 105,5 0,00 67,66 - - 0,00 0,00-0,00 6 1 004 1 012 31,19 105,5 0,00 71,11 - - 0,00 0,00-0,00 7 1 585 1 590 25,99 105,5 0,00 75,03 - - 0,00 0,00-0,00 8 1 630 1 635 25,66 105,5 0,00 75,27 - - 0,00 0,00-0,00 9 926 935 32,07 105,5 0,00 70,42 - - 0,00 0,00-0,00 Sum 39,59 Noise sensitive area: I Asuinrakennus (Peltola) 1 1 765 1 769 24,72 105,5 0,00 75,96 - - 0,00 0,00-0,00 2 2 192 2 196 22,08 105,5 0,00 77,83 - - 0,00 0,00-0,00 3 1 789 1 793 24,56 105,5 0,00 76,07 - - 0,00 0,00-0,00 4 1 482 1 487 26,78 105,5 0,00 74,45 - - 0,00 0,00-0,00 5 2 072 2 077 22,77 105,5 0,00 77,35 - - 0,00 0,00-0,00 6 1 703 1 708 25,14 105,5 0,00 75,65 - - 0,00 0,00-0,00 7 1 185 1 192 29,34 105,5 0,00 72,53 - - 0,00 0,00-0,00 8 1 512 1 517 26,55 105,5 0,00 74,62 - - 0,00 0,00-0,00 9 1 954 1 958 23,49 105,5 0,00 76,84 - - 0,00 0,00-0,00 Sum 35,14 Noise sensitive area: J Asuinrakennus (Hilsvida) 1 1 111 1 117 30,08 105,5 0,00 71,96 - - 0,00 0,00-0,00 2 1 630 1 635 25,66 105,5 0,00 75,27 - - 0,00 0,00-0,00 3 1 407 1 413 27,38 105,5 0,00 74,00 - - 0,00 0,00-0,00 4 1 365 1 370 27,74 105,5 0,00 73,74 - - 0,00 0,00-0,00 5 1 935 1 939 23,61 105,5 0,00 76,75 - - 0,00 0,00-0,00 6 1 714 1 719 25,07 105,5 0,00 75,70 - - 0,00 0,00-0,00 7 1 400 1 406 27,44 105,5 0,00 73,96 - - 0,00 0,00-0,00 8 1 873 1 877 24,00 105,5 0,00 76,47 - - 0,00 0,00-0,00 9 2 074 2 078 22,76 105,5 0,00 77,35 - - 0,00 0,00-0,00 Sum 36,10

DECIBEL - Detailed results 13.6.2013 19:22 / 6 Noise sensitive area: K Asuinrakennus (Mysskärri) 1 891 899 32,51 105,5 0,00 70,07 - - 0,00 0,00-0,00 2 1 467 1 473 26,89 105,5 0,00 74,36 - - 0,00 0,00-0,00 3 1 588 1 593 25,97 105,5 0,00 75,04 - - 0,00 0,00-0,00 4 1 837 1 841 24,24 105,5 0,00 76,30 - - 0,00 0,00-0,00 5 2 291 2 295 21,53 105,5 0,00 78,22 - - 0,00 0,00-0,00 6 2 231 2 234 21,87 105,5 0,00 77,98 - - 0,00 0,00-0,00 7 2 090 2 094 22,67 105,5 0,00 77,42 - - 0,00 0,00-0,00 8 2 598 2 601 19,96 105,5 0,00 79,30 - - 0,00 0,00-0,00 9 2 635 2 638 19,78 105,5 0,00 79,43 - - 0,00 0,00-0,00 Sum 35,57 Noise sensitive area: L Lomarakennus 1 1 255 1 261 28,70 105,5 0,00 73,01 - - 0,00 0,00-0,00 2 1 818 1 823 24,36 105,5 0,00 76,22 - - 0,00 0,00-0,00 3 1 967 1 971 23,41 105,5 0,00 76,89 - - 0,00 0,00-0,00 4 2 203 2 206 22,02 105,5 0,00 77,87 - - 0,00 0,00-0,00 5 2 669 2 672 19,62 105,5 0,00 79,54 - - 0,00 0,00-0,00 6 2 595 2 598 19,98 105,5 0,00 79,29 - - 0,00 0,00-0,00 7 2 417 2 421 20,87 105,5 0,00 78,68 - - 0,00 0,00-0,00 8 2 916 2 919 18,49 105,5 0,00 80,31 - - 0,00 0,00-0,00 9 2 995 2 998 18,15 105,5 0,00 80,54 - - 0,00 0,00-0,00 Sum 32,65 Noise sensitive area: M Lomarakennus (Källarbottnen) 1 2 590 2 593 20,00 105,5 0,00 79,27 - - 0,00 0,00-0,00 2 3 123 3 125 17,61 105,5 0,00 80,90 - - 0,00 0,00-0,00 3 3 323 3 325 16,80 105,5 0,00 81,44 - - 0,00 0,00-0,00 4 3 541 3 543 15,97 105,5 0,00 81,99 - - 0,00 0,00-0,00 5 4 024 4 026 14,45 105,5 0,00 83,10 - - 0,00 0,00-0,00 6 3 927 3 929 14,74 105,5 0,00 82,88 - - 0,00 0,00-0,00 7 3 682 3 684 15,48 105,5 0,00 82,33 - - 0,00 0,00-0,00 8 4 154 4 155 14,09 105,5 0,00 83,37 - - 0,00 0,00-0,00 9 4 317 4 319 13,63 105,5 0,00 83,71 - - 0,00 0,00-0,00 Sum 25,88 Noise sensitive area: N Lomarakennus 1 1 758 1 760 24,78 105,5 0,00 75,91 - - 0,00 0,00-0,00 2 1 918 1 921 23,72 105,5 0,00 76,67 - - 0,00 0,00-0,00 3 2 461 2 464 20,65 105,5 0,00 78,83 - - 0,00 0,00-0,00 4 2 975 2 977 18,24 105,5 0,00 80,48 - - 0,00 0,00-0,00 5 3 172 3 174 17,41 105,5 0,00 81,03 - - 0,00 0,00-0,00 6 3 341 3 343 16,74 105,5 0,00 81,48 - - 0,00 0,00-0,00 7 3 443 3 444 16,34 105,5 0,00 81,74 - - 0,00 0,00-0,00 8 3 951 3 952 14,67 105,5 0,00 82,94 - - 0,00 0,00-0,00 9 3 744 3 746 15,29 105,5 0,00 82,47 - - 0,00 0,00-0,00 Sum 29,67

DECIBEL - Assumptions for noise calculation 13.6.2013 19:22 / 7 Noise calculation model: ISO 9613-2 General Wind speed: 8,0 m/s Ground attenuation: General, Ground factor: 0,5 Meteorological coefficient, C0: 0,0 db Type of demand in calculation: 1: noise is compared to demand (DK, DE, SE, NL etc.) Noise values in calculation: All noise values are mean values (Lwa) (Normal) Pure tones: Pure and Impulse tone penalty are added to source noise Height above ground level, when no value in NSA object: 1,5 m Don't allow override of model height with height from NSA object Deviation from "official" noise demands. Negative is more restrictive, positive is less restrictive.: 0,0 db(a) Octave data required Air absorption 63 125 250 500 1 000 2 000 4 000 8 000 [db/km] [db/km] [db/km] [db/km] [db/km] [db/km] [db/km] [db/km] 0,1 0,4 1,0 1,9 3,7 9,7 32,8 117,0 :!O! Noise: Runtime input Octave data Status Hub height Wind speed LwA,ref Pure tones 63 125 250 500 1000 2000 4000 8000 [m] [m/s] [db(a)] [db] [db] [db] [db] [db] [db] [db] [db] User value 120,0 8,0 105,5 No Generic data 87,1 94,1 97,5 100,1 99,9 97,0 92,2 82,7 NSA: Asuinrakennus (Seppälä)-A NSA: Asuinrakennus-B NSA: Asuinrakennus (Mäkelä)-C NSA: Asuinrakennus (Metsola)-D

DECIBEL - Assumptions for noise calculation 13.6.2013 19:22 / 8 NSA: Asuinrakennus-E NSA: Lomarakennus-F NSA: Asuinrakennus (Majanders)-G NSA: Asuinrakennus (Simosäng)-H NSA: Asuinrakennus (Peltola)-I NSA: Asuinrakennus (Hilsvida)-J NSA: Asuinrakennus (Mysskärri)-K NSA: Lomarakennus-L NSA: Lomarakennus (Källarbottnen)-M Noise demand: 35,0 db(a)

DECIBEL - Assumptions for noise calculation 13.6.2013 19:22 / 9 NSA: Lomarakennus-N

DECIBEL - Map 8,0 m/s 13.6.2013 19:22 / 10 Noise [db(a)] 35 40 45 0 500 1000 1500 2000 m Map: Peruskartat kaikki, Print scale 1:30 000, Map center Finish GK KKJ (3 deg)-kkj (FI 1992 <±5m) Zone: 3 East: 3 482 930 North: 6 706 787 New Noise sensitive area Noise calculation model: ISO 9613-2 General. Height above sea level from active line object