Connection and performance of two-way CLT plates

Similar documents
EVALUATING ROLLING SHEAR STRENGTH PROPERTIES OF CROSS LAMINATED TIMBER BY TORSIONAL SHEAR TESTS AND BENDING TESTS

Investigations on the Effectiveness of Self-tapping Screws in Reinforcing Bolted Timber Connections

Structural Strength of Lapped Cold-Formed Steel Z-Shaped Purlin Connections with Vertical Slotted Holes

EFFECTS OF GEOMETRY ON MECHANICAL BEHAVIOR OF DOVETAIL CONNECTION

Korean standards of visual grading and establishing allowable properties of softwood structural lumber

Dowel connections in laminated strand lumber

Canadian li ing device design for Cross Laminated Timber (CLT)

European Technical Assessment ETA-12/0197 of 12/07/2017

European Technical Assessment ETA-13/0029 of 11/07/2017

Space-frame connection for small-diameter round timber

Moment-Resisting Connections In Laminated Veneer Lumber (LVL) Frames

Lawrence A. Soltis, M. and Robert J. Ross, M. 1

European Technical Assessment ETA-17/1005 of

THE ENGINEERED WOOD ASSOCIATION

TEST SERIES TO EVALUATE THE STRUCTURAL BEHAVIOUR OF ISOBOARD OVER RAFTER SYSTEM

American Institute of Timber Construction 7012 South Revere Parkway Suite 140 Centennial, CO Phone: 303/ Fax: 303/

Pull-compression tests on glued-in metric thread rods parallel to grain in different timber species and laminated veneer lumber

Anti-check bolts as means of repair for damaged split ring connections

1. Enumerate the most commonly used engineering materials and state some important properties and their engineering applications.

APA Performance Rated Rim Boards

Load Tables, Technical Data and Installation Instructions

Tension Perpendicular to Grain Strength of Wood, Laminated Veneer Lumber (LVL), and Cross-Banded LVL (LVL-C)

AN IMPROVED SHEAR TEST FIXTURE USING THE IOSIPESCU SPECIMEN

Simplified analysis of timber rivet connections

Ph.D. Preliminary Qualifying Examination. Cover Page. Thermodynamic. January 17, 2013 (Thursday) 9:30 am 12:30 noon Room 2145 Engineering Building

A STUDY ON PATTERN DAMAGE OF FINGER JOINTS IN BAMBOO LAMINATED BEAMS

SIMPLIFIED DESIGN PROCEDURE FOR GLUED-LAMINATED BRIDGE DECKS

STRUCTURAL TIMBER DESIGN

European Technical Assessment ETA-11/0024 of 02/03/2017

MAT105: Floor Framing

Connections in CLT Assemblies

Hazlan Abdul Hamid* & Mohammad Iqbal Shah Harsad

LVL8 H1.2 GENERAL FRAMING. Eco Friendly Revolutionary H1.2 Treatment Azotek by Zelam

STRUCTURAL ATTACHMENTS

Ingenious hardwood. Ingenious hardwood. Order our BauBuche sample box free of charge. 1

Attach Trusses and Rafters Faster

SDWH TIMBER-HEX Screw

Effect of finger length on fingerjoint strength in radiata pine

2002 ADDENDUM to the 1997 NDS and PRIOR EDITIONS

BauBuche Fasteners and connections

Verbindungselemente Engel GmbH Weltestraße Weingarten DEUTSCHLAND. Manufacturing plant 74437, , ,

Keywords: Bracing bracket connection, local deformation, selective pallet racks, shear stiffness, spine bracings.

Three-dimensional finite element analysis of the Japanese traditional post-and-beam connection

Glued laminated timber beams repair.

European Technical Assessment ETA-11/0024 of 08/07/2016

THE EFFECT OF END DISTANCE AND NUMBER OF READY-TO- ASSEMBLE FURNITURE FASTENERS ON BENDING MOMENT RESISTANCE OF CORNER JOINTS.

Tension Perpendicular to Grain Strength of Wood, Laminated Veneer Lumber, and a Wood Plastic Composite.

SCREWS WITH CONTINUOUS THREADS IN TIMBER CONNECTIONS

Glulam Connection Details

Made from Visually Graded Hem-Fir Lumber

Moment resistance of bolted timber connections with perpendicular to grain reinforcements

The Behaviour Of Round Timber Sections Notched Over The Support On The Tension Face. Justin Dewey

Cyclic tests of engineered shear walls with different bottom plate and anchor bolt washer sizes (Phase II)

EVALUATION OF SINGLE MEMBERS IN HISTORICAL STRUCTURES

STRUCTURAL FINGER JOINTED SOLID TIMBER

Load tables for a transport anchor system with Würth ASSY 3.0 combi self-tapping screws = 12 mm as defined under ETA-11/0190 (6/27/2013)

Load tables for a transport anchor system with Würth ASSY 3.0 combi self-tapping screws = 10 mm as defined under ETA-11/0190 (6/27/2013)

Load tables for a transport anchor system with Würth ASSY 3.0 combi self-tapping screws = 12 mm as defined under ETA-11/0190 (6/27/2013)

VERSA-LAM. An Introduction to VERSA-LAM Products

Experimental Evaluation of Metal Composite Multi Bolt Radial Joint on Laminate Level, under uni Axial Tensile Loading

Tensile strength of ASSY plus VG screws wood-wood (softwood)

Sturdi-Wall Design Manual for SW46, SW66, SW63, SW64, SW60, SW83, SW84, and SW80 Models

Experimental and numerical study of nailed laminated timber elements for in plane and transverse loading

M. Bücker*, M. Magin. Institute for Composite Materials, Erwin-Schrödinger-Straße 58, Kaiserslautern, Germany

European Technical Assessment. ETA-16/0902 of 17 March English translation prepared by DIBt - Original version in German language.

1/2/2016. Lecture Slides. Screws, Fasteners, and the Design of Nonpermanent Joints. Reasons for Non-permanent Fasteners

T10F. Data Sheet. Torque Flange. Special features. Installation example T10F. B en

Please do not open this exam until you are told to do so.

LP SolidStart Laminated Strand Lumber and Laminated Veneer Lumber Louisiana-Pacific Corporation Revised May 6, 2011

European Technical Approval ETA-12/0114

LP SolidStart Laminated Strand Lumber (LSL) and Laminated Veneer Lumber (LVL) Louisiana-Pacific Corporation Revised July 21, 2017

Screw Withdrawal A Means to Evaluate Densities of In-situ Wood Members

Effect of Vertical Load under Cyclic Lateral Load Test for Evaluating Sugi CLT Wall Panel

Connection Design Examples

DESIGN OF MACHINE MEMBERS-I

PERFORMANCE OF COMPOSITE SHEAR WALL PANEL OF LVL AND GRC BOARD

Lateral Load-Bearing Capacity of Nailed Joints Based on the Yield Theory

NAILED MORTISED-PLATE CONNECTIONS FOR SMALL-DIAMETER ROUND TIMBER 1. Kug-Bo Shim* Ronald W. Wolfe. Marshall Begel

EVALUATING BEARING PROPERTIES OF WOOD PEG CONNECTION USING FOUR DIFFERENT TEST METHODS. G. Y. Jeong* J. H. Kong

Glulam Curved Members. Glulam Design. General Glulam Design. General Glulam Beams are Designed in the SAME Manner as Solid Sawn Beams

Standard Test Methods for Small Clear Specimens of Timber 1

EVALUATION OF SCREWS USED IN LAMINATED VENEER LUMBER ROCKING CONNECTIONS

Section Downloads. Lumber Design Values. Lumber Standard. Western Lumber Product Use Manual. Section 05: Truss Materials.

Featuring TJ Rim Board and TimberStrand LSL

4-Bolt Wood-to-Steel Connections

CH # 8. Two rectangular metal pieces, the aim is to join them

Development of a New-Generation Dowel and Screw Combination 2014 International Crosstie and Fastening System Symposium Urbana, IL, USA 3 June 2014

Changes in the 2001 NDS for Wood Construction

CHARACTERISTICS OF LUMBER-TO-LUMBER FRAMING CONNECTIONS IN LIGHT-FRAME WOOD STRUCTURES

Standard Test Method for Rubber Measurement of Unvulcanized Rheological Properties Using Rotorless Shear Rheometers 1

ICBO ES ER-5598 n HUD MR 1310 DSA PA-123 n LAC RR25448 n CCMC R. Limit States Design

Beam & Header Technical Guide. LP SolidStart LVL. 2900F b -2.0E. U.S. Technical Guide U.S. TECHNICAL GUIDE

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD, PLASTIC AND COMPOSITE FASTENINGS REPORT HOLDER: DEWALT

ICC-ES Evaluation Report

Bolt Spacing and End Distance of Bolted Connection of Laminated Veneer Lumber (LVL) Sengon

GLUED SOLID TIMBER DUO/TRIO

Standard Test Methods of Static Tests of Wood Poles 1

Connection Philosophy. p NDS Chapter-by-chapter description Changes from previous editions Examples. Part 1: Member Design Webinar.

EVALUATION OF BOLTED CONNECTIONS IN WOOD PLASTIC COMPOSITES DAVID ALAN BALMA

Development of wooden-based nails for wooden pallet

Transcription:

Connection and performance of two-way CLT plates by Chao (Tom) Zhang George Lee Dr. Frank Lam Prepared for Forestry Innovation Investment 1130 W Pender St, Vancouver BC V6E 4A4 Timber Engineering and Applied Mechanics (TEAM) Laboratory Department of Wood Science Faculty of Forestry University of British Columbia Vancouver, B.C., Canada TL-333 April 6, 2018 Timber Engineering and Applied Mechanics (TEAM) Laboratory #1901-2424 Main Mall, Vancouver, B.C. Canada V6T 1Z4; Tel: (604) 822-8137 Fax: (604) 822-9159

EXECUTIVE SUMMARY The two-way action of Cross Laminated Timber (CLT) is often ignored in the design of CLT due to its complexity. But in some cases, for example, large span timber floor/roof, the benefit of taking the two-way action into account may be considerable since it is often deflection controlled in the design. Furthermore CLT panels are typically limited to widths of less than 3 m. therefore, for practical applications, engaging CLT panels in two-way action as a plate in bending would require connecting two panels in the width/minor direction to take out-of-plane loading. To address this technically difficult situation, an innovative connection was developed to join the CLT panels in the minor direction to form a large continuous two-way plate. The two-way action of CLT was also quantified. Static bending test was conducted on CLT panels in the major and minor directions to measure the Modulus of Elasticity (MOE). This provided a benchmark for the following connection test, and data for the future development of computer modeling. The average apparent MOE was 9.09 GPa in the major direction and 2.37 GPa in the minor direction. Several connection techniques were considered and tested, including self-tapping wood screws, glued in steel rods, and steel connectors. One connecting system was found to be effective. For the panel configuration considered, the system was consisted of steel plates, self-tapping wood screws, and 45 screw washers. Two steel plates were placed on the tension side with sixteen screws, and one steel plates was placed on the compression side with four screws. When the screws were driven into the wood, the screws were tightly locked with the washers and steel plates, and at the same time, the wood members were pulled together by the screws. This eliminated any original gap within the connection. The connector was installed to join two CLT members in the minor direction. They were tested under bending with the same setup as above. The connected panels had an average apparent MOE of 2.37 GPa, and an average shear-free MOE of 2.44 GPa, both of which were higher than the counterpart in the full panels. The moment capacity of the connected panels was also high. The minimum moment capacity was 3.2 times the design value. Two large CLT panels were tested under concentrated loading with four corners simply supported. The deflection of nine locations within the panels was measured. This data will be used to validate the computer modeling for CLT two-way action. Reported by: Reviewed by: Chao (Tom) Zhang George Lee Frank C.F. Lam, Ph.D., P. Eng. Research Engineer Wood Engineering Scientist Professor PAGE 2/16

TABLE OF CONTENT EXECUTIVE SUMMARY... 2 Table of Content... 3 List of Tables... 4 List of Figures... 4 1 Introduction... 5 2 Material and Methods... 5 2.1 CLT bending test... 6 2.2 CLT connection test... 7 2.3 Two-way CLT plate test... 9 3 Results and Discussions... 10 4 Conclusions... 15 5 References... 15 Appendix A Specifications of steel plates... 16 PAGE 3/16

LIST OF TABLES Table 1 Material list... 5 Table 2 Test configurations... 5 Table 3 MOE of full CLT panels in the major and minor directions... 10 Table 4 Properties of connected CLT panels in the minor direction... 10 LIST OF FIGURES Figure 1 CLT bending test setup... 6 Figure 2 Connection configuration: steel plate locations... 8 Figure 3 Connection configuration: screws and washers... 8 Figure 4 Connection installation... 8 Figure 5 Support and transducer locations in two-way CLT plate test... 9 Figure 6 Test setup of two-way CLT plate test... 9 Figure 7 Failure mode of connected CLT panels under bending... 11 Figure 8 Load-displacement relationship of connected CLT panels under bending... 11 Figure 9 Displacement of Panel #1 along the major direction... 12 Figure 10 Displacement of Panel #1 along the minor direction... 13 Figure 11 Displacement of Panel #2 along the major direction... 13 Figure 12 Displacement of Panel #2 along the minor direction... 14 Figure 13 Displacement after the load was released... 14 Figure A- 1 Steel plate size and slot locations... 16 PAGE 4/16

1 INTRODUCTION Cross Laminated Timber (CLT) is an important structural element widely used as walls and floor/roof members in mass timber construction. Typically CLT floors are considered as one-way bending elements supported by walls or beams, although CLT has two way plate bending capacity as a result of the multiple alternating layers of wood elements. Since the governing factor for floor design is often deflection, CLT with two-way bending action may be a plausible solution for large span timber floor/roof. The minor direction may make considerable contribution to the stiffness of CLT, especially for thicker panels. Commercially available CLT panels are typically limited to widths of less than 3 m. For practical applications, engaging CLT panels in two way action as a plate in bending would normally require connecting two panels in the width/minor direction. This connection system would need to allow the CLT panels to sustain out-of-plane loading. This project developed and tested connections used to join multiple CLT panels into a large continuous two-way plate, and the two-way action of CLT plate was quantified. 2 MATERIAL AND METHODS The material used in the manufacturing and testing of specimens is shown in Table 1. The CLT was E1M5 175E 5 layer, manufactured by Structurlam Products Ltd. (Penticton, BC). The lumber in the major direction layers was MSR 2100 1.8E Spruce-Pine-Fir (SPF), and the lumber in the minor direction layers was SPF #2 & Better. The screws, washers, and pre-drilling jig were made by SWG Schraubenwerk Gaisbach GmbH (Waldenburg, Germany). The screws were fully threaded self-tapping wood screws with a diameter of 12 mm, and a length of 140 mm. Table 1 Material list Item CLT Screws Washers Steel plate Description E1M5 175 E 5 layer, 175 mm thick ASSY Plus VG screws 12 140, CSK head, milling pocket 45 washers for 12 mm countersunk screw head A36, 6.4 mm thick, 127 mm wide Pre-drilling jig For 12 mm screws at 45 Table 2 Test configurations Test Replicates Orientation Specimen size Bending test 10 Major Width 305 mm, length 3.66 m 10 Minor Width 305 mm, length 3.66 m Connection test 10 Minor Width 305 mm, length 3.66 m Two-way plate test 2 Both Width 1.83 m, length 3.66 m PAGE 5/16

Three types of tests were conducted: the bending tests measured the Modulus of Elasticity (MOE) of intact CLT panels in its major and minor direction; the connection tests investigated the performance of two CLT panels joined together in the minor direction; the two-way plate tests evaluated the behavior of CLT in the two directions under a concentrated load in the center. The test configurations are shown in Table 2. 2.1 CLT bending test The static bending test was conducted in accordance with the third-point load method in ASTM D198-15. The load was applied equally on two loading points located at one third of the span from the reactions. The test setup is shown in Figure 1. The span was 3150 mm and the span/depth ratio was 18:1. The loading rate was 5 mm/min. The deflection of the midspan relative to the supports on the neutral axis, and the deflection of the midspan relative to the two loading points on the neutral axis were measured by two LVDT transducers with yokes. The specimens with surface layers in the major direction was loaded to 20 kn, and the specimens with surface layers in the minor direction was loaded to 10 kn. The test was non-destructive since only MOE was to be measured. The moisture content of CLT was measured by Delmhorst RDM wood moisture meter. Figure 1 CLT bending test setup Two types of modulus of elasticity were defined and calculated in accordance with Section X.2 of ASTM D198-15. The apparent modulus of elasticity (MOEapp) was determined by the deflection of the midspan in relation to the two supports, thus MOEapp included the shear effect. The shear-free modulus of elasticity (MOEsf) was determined by the deflection of the midspan in relation to the two loading points, which was in shear-free span. The equations to calculate MOEapp, and MOEsf are as follows: 3 23Pl MOE app (1) 108 bd 3 PAGE 6/16

MOE sf Pl l 2 sf 4bd 3 sf (2) where: MOEapp: apparent modulus of elasticity, calculated by the deflection within the full span (GPa) MOEsf: shear-free modulus of elasticity, calculated by the deflection within the shear free span (GPa) P: increment of applied load below proportional limit (N) l: span of beam (mm) lsf: shear-free span, the distance between the two loading points in this case (mm) : increment of deflection of the neutral axis measured at midspan over distance L (mm) sf : increment of deflection of the neutral axis measured at midspan over distance lsf, (mm) b: width of beam (mm) d: depth of beam (mm) After measuring MOE, the ten specimens with surface layers in the minor direction were cut into halves for the following connection test. The two halves from the same specimen were joined together. 2.2 CLT connection test The connection of two CLT panels in the minor direction is critical to the application of continuous two-way CLT plate. Since the design of large span CLT floor is governed by deflection, the aim is to achieve a joined panel having equivalent stiffness compared to the intact panel. Several connection techniques were considered and tested, including selftapping wood screws, glued in steel rods, and steel connectors. Only the optimal solution is presented here. The connector was consisted of steel plates, self-tapping wood screws, and 45 screw washers. Elliptic washer slots were machined on the steel plates to fit the washers. The size and slot locations are shown in Appendix A. The tolerance for the length and width of the slots was ±1 mm. The minimum edge spacing for the screws was 36 mm. Two long plates were manufactured for the tension side, and one short plate for the compression side. The center of the steel plates was aligned with the connecting interface between the two CLT. Pilot holes were drilled by using the pre-drilling jig and the diameter of the predrilling bit was 6.35 mm (¼").The depth of the pilot holes was less than 50 mm. The connection configuration is shown in Figures 2-3. The connection after installation is PAGE 7/16

shown in Figure 4. The connected CLT panels were tested under third-pint bending with the same setup shown in Section 2.1. Figure 2 Connection configuration: steel plate locations Figure 3 Connection configuration: screws and washers Figure 4 Connection installation PAGE 8/16

2.3 Two-way CLT plate test This test was designed to investigate the two-way behavior of CLT plate, and obtain data for the future development of computer modeling. The test was conducted under concentrated loading and the panel was simply supported at the four corners, as shown in Figure 5. Nine transducers were installed to measure the deflection of the floor at different locations. The load was applied on an area of 240 mm by 400 mm at the center. Five steel plates were added one by one at an interval of 5 min. Each steel plate had a weight of 791.5 kg, equivalent to 7.76 kn. The test setup is shown in Figure 6. The specimens were not loaded to failure. Figure 5 Support and transducer locations in two-way CLT plate test Figure 6 Test setup of two-way CLT plate test PAGE 9/16

3 RESULTS AND DISCUSSIONS The average moisture content of the CLT tested was 14.6%. The results of the CLT bending test are shown in Table 3. The average MOEapp in the major direction was 9.09 GPa, with a CV of 4%. The average MOEapp in the minor direction was 2.37 GPa, about 26% of the MOEapp in the major direction. The MOEsf was higher than MOEapp in both groups, and the difference was higher in the major direction. Table 3 MOE of full CLT panels in the major and minor directions Full panels MOE app (GPa) Major direction MOE sf (GPa) MOE sf/ MOE app MOE app (GPa) Minor direction MOE sf (GPa) MOE sf/ MOE app Max 9.65 10.73 118% 2.65 2.80 107% Min 8.57 9.29 105% 2.01 2.03 100% Average 9.09 10.04 111% 2.37 2.45 103% Stdev 0.39 0.49 4% 0.19 0.20 2% CV 4% 5% 4% 8% 8% 2% Replicates 10 10 10 10 10 10 The properties of the connected CLT panels are shown in Table 4. The connected panels had higher MOEapp and MOEsf than the full panels in the minor direction. On average the increase was 9% for MOEsf and 4% for MOEapp. The average MOR was 11.5 MPa with a coefficient of variation of 7%. The minimum moment capacity was 51.9 kn m/m, 3.2 times the design moment capacity of 16.0 kn m/m. The failure mode of the connected panels is shown in Figure 7. The failure occurred at the interface between the bottom layer and the adjacent longitudinal layer, in the form of tension-shear. No visible damage to the screw or steel plate was observed. Examples of load-displacement relationship are shown in Figure 8. The failure was brittle in most specimens. Table 4 Properties of connected CLT panels in the minor direction Connected panels MOE app (GPa) MOE sf (GPa) MOE sf/ MOE app Peak load (kn) MOR (MPa) M (kn m/m) Max 2.69 3.12 120% 36.24 12.17 63.4 Min 2.27 2.22 92% 29.72 9.97 51.9 Average 2.46 2.67 109% 34.36 11.50 59.9 Stdev 0.13 0.34 11% 2.34 0.77 4.0 CV 5% 13% 10% 7% 7% 7% Replicates 10 10 10 10 10 10 PAGE 10/16

Figure 7 Failure mode of connected CLT panels under bending Figure 8 Load-displacement relationship of connected CLT panels under bending Based on the connection method proposed, the stiffness and strength of the connected CLT specimens exceeded the values of the intact panels. The screws were tightly locked with the washers and steel plates when they were driven into the wood. The torsion/tension created between the wood and screws also pulled the CLT members together. In the end, this technique eliminated the original gap within the connection, which had been a PAGE 11/16

persistent problem during the testing of other connecting methods. Due to the high stiffness of steel, the main displacement occurred between the screw and wood on the tension side. Therefore, the critical factor was the lateral stiffness of the screw in wood. In the current configuration, the screws were pressing against the wood perpendicular to grain, on the first layer of the tension side. This was one reason why large number of screws had to be installed. The number of screws required to reach certain stiffness may be calculated from the lateral stiffness of a single screw. The effects of screw length, screw diameter, screw pattern, steel plate thickness, and steel plate shape on the performance and cost of the connection are yet to be investigated. The number of screws and the amount of steel plates used are expected to be reduced after further optimization. The deflection of the two-way CLT plate under concentrated loading is shown in Figures 8-11.The center deflection relative to the panel edges was greater along the major direction than the minor direction. The maximum deflection of Panel #2 was 5.67 mm, about 10% lower than that of Panel #1. And this trend was observed at every point of measurement. The deflection along the major direction was much higher than that along the minor direction. The relative center displacement relative to the edge was 4.11-4.38 mm in the major direction, and 0.79-0.82 mm in the minor direction. After the load was released, some residual deflection remained, as shown in Figure 13. The amount of residual deflection was less than <0.3 mm. Figure 9 Displacement of Panel #1 along the major direction PAGE 12/16

Figure 10 Displacement of Panel #1 along the minor direction Figure 11 Displacement of Panel #2 along the major direction PAGE 13/16

Figure 12 Displacement of Panel #2 along the minor direction Figure 13 Displacement after the load was released PAGE 14/16

4 CONCLUSIONS An innovative connection for joining the minor direction of CLT panels was developed and tested. The connector is based on self-tapping wood screws, steel plates, and 45 cast iron screw washers. It is easy to work with and fast to install. When the screws are driven in, the system has a locking mechanism to close any initial gap between CLT members, as well as between washers and steel plates. Therefore, the stiffness of the connected specimens exceeded that of the full panels. The minimum moment capacity of the cross section was 3.2 times the design value. The connection was found to be effective in joining two CLT panels in the minor direction. The large span two-way CLT floor/roof created by this system can be conservatively considered as a one continuous CLT plate without connections in the design. The two-way action of CLT plates was quantified in the test. This data will be used to calibrate the computer modeling of two-way CLT. 5 ACKNOWLEDGEMENTS This project was financially supported by Forestry Innovation Investment. The material support from Structurlam Products Ltd. is gratefully acknowledged. 6 REFERENCES ASTM D198-15, Standard Test Methods of Static Tests of Lumber in Structural Sizes, ASTM International, West Conshohocken, PA, 2015, www.astm.org PAGE 15/16

Appendix A Specifications of steel plates Figure A- 1 Steel plate size and slot locations THE END PAGE 16/16