WESAN WP E ELECTRONIC METER WOLTMAN

Similar documents
RAY MECHANICAL COMPACT METER. 4 MID approved class 2 from ND 15 mm qp 0,6 m3/h up to ND 40 mm qp 10 m3/h

RAY COMPACT ENERGY METER MECHANICAL

RAY MC COMPACT ENERGY METER MECHANICAL

RAY MC COMPACT ENERGY METER MECHANICAL

SHARKY 775 ULTRASONIC COMPACT METER. 4 Approval with dynamic range up to 1:250 (qi:qp) MID in class 2 (depends on meter size), standard 1:100

SHARKY 775 ULTRASONIC COMPACT METER. 4 Approved according EN 1434 and MID in class 2 with dynamic range of 1:250 (qi:qp) in class 2

SHARKY 775 ULTRASONIC COMPACT METER. 4 Approved according EN 1434 and MID in class 2 with dynamic range of 1:250 (qi:qp) in class 2

Brunata Optuna H. Properties. Counter

EW447-EW452 Series Mechanical Heatmeters FOR HEATING AND COOLING APPLICATIONS

SONOMETER TM 1100 Ultrasonic compact energy meter

SonoMeter 31 Energy Meters

SONO 1500 CT Ultrasonic flow sensor

INFOCAL 8 Energy calculator

SONOMETER TM 1100 Ultrasonic compact energy meter

Infocal 9 Energy calculator

SVM F27 Compact. Ultrasonic heatmeter. Data sheet

ULTRASONIC D. Compact ultrasonic heat meter

SVM F27 / C27. Ultrasonic BTU meter for heating or cooling. Data sheet

Flow Measurement SITRANS F US Inline

Residential Water Meters

Brunata Optuna H Ultrasonic energy meter Type 775 Installation Guide Edition 1.2

SITRANS F flowmeters SITRANS F US. Flowmeter FUE380 with approval. 4/230 Siemens FI Overview

Flow Measurement. SITRANS F US Inline. Flowmeter SITRANS FUS380 standard. 4/254 Siemens FI Overview

ULTRAFLOW TS PTB. Application. Ultrasonic flow sensor. Compact design. Static meter with no moving parts. Large dynamic range.

WATERFLUX 3070 Technical Datasheet

NUBIS. R t o WATER MEASUREMENT

MID MP-01, MP WATER MEASUREMENT

Size : Connection End : Min Temperature : Max Temperature : Materials : Cast iron body

Bulk water meter. All that c ou n t s. EnergyMetering

ULTRAFLOW. Application. Cooling flow sensor. Ultrasonic flow sensor. Compact design. Static meter with no moving parts. Large dynamic range.

flowiq 3100 Data sheet

Release A Member of the

SONOMETER TM 1000 Ultrasonic compact heat meter

SITRANS F flowmeters SITRANS F US SONOCAL /184 Siemens FI

SonoSelect 10 and SonoSafe 10 Energy Meters

SONOMETER 2000 Ultrasonic heat meter

Heat meter Q heat 5 US

Design and applications

Flow Measurement SITRANS F US Inline

Size : Connection Ends : Min Temperature : Max Temperature : Materials : Cast iron body

Metering systems 0527EN January 2014 Sanitary water meter, GE552-2 series Versions for wireless centralisation

Metering systems 0474EN April 2018 Domestic water meter

Smart Mobile Metering Solutions WALK-BY OR DRIVE-BY READING HYDRUS SMART METERS AND IZAR SYSTEM COMPONENTS

KFS-EM. Overall length. Al. PTFE coated Alu, painted Al. coated Methacrylate / acrylic nitrite

Q water 5.5. Electronic water meter. Data sheet DST1-QWA5-EN0 WMEAP / V 2.1

Instruction. SONOMETER 1100 Ultrasonic compact energy meter. 1.0 Table of contents. 2.0 Safety notes and product information

Nubis propeller water meter with horizontal impeller axle

ULTRAFLOW TS Application OIML R75 DS/EN 1434

KFS. Flap-type flow meter. Design and range of application

Portfolio. and ULTRAWATER. Ultrasonic Static Meters. Ultrasonic Meters Residential and District Heating/ Cooling Water Measurement

INLINE flowmeter for continuous flow measurement

Applications. Features RESIDENTIAL ULTRASONIC WATER METER. Revenue metering Residential submetering Commercial buildings.

Instruction. INFOCAL 8 Energy calculator. 1.0 Table of contents. 2.0 Safety notes and product information

Digital flow transmitter for continuous flow measurement

wprime TM Series 280W-CI ULTRASONIC WATER METER

INLINE flowmeter for continuous flow measurement

ICARUS ELECTRONIC GAS VOLUME CONVERTER

The innovative way forward symphonic sensor net radio system

Flow Switch - 2 programmable thresholds. Stand Alone (Battery) - Battery powered, - 2 totalizers display, - Local flow display,

Applications. Features RESIDENTIAL ULTRASONIC WATER METER. Revenue metering Residential submetering Commercial buildings.

SN+ MID MASTER + APPLICATION WATER METERS

FLOMID FX Electromagnetic Flowmeter

flowiq 3100 Data sheet

SITRANS F flowmeters. SITRANS F System information MAGFLO electromagnetic flowmeters 4/9

( F L O W I Z F A M I L Y )

Express Delivery. Axial. Connection

INSERTION paddle wheel flowmeter for continuous flow measurement

MULTICAL 302 DATA SHEET

INLINE flowmeter for continuous flow measurement

MULTICAL 601 DATA SHEET

Device Manual Chapter 4.1-R optosonic u 3 radio net

12/2 Product overview. 12/3 7KT1 14, 7KT1 53 E-counters. 12/9 7KT1 11, 7KT1 12 digital measuring devices. 12/11 7KT1 0 analog measuring devices

SITRANS F flowmeters SITRANS F M. Flow sensor MAG /48 Siemens FI Overview

Electronic device for recording the share of heat output by radiators.

Measurement. SITRANS F US Inline. 3/262 Siemens FI Transmitter SITRANS FUS080/FUE080

This data sheet is only valid in association with the IL SYS INST UM E user manual.

Flow Measurement SITRANS F M. Flow sensor MAG /49. Overview

Lexium integrated drives

PRELIMINARY DATA SHEET RI-D140. Three Phase Multifunction DIN Rail Energy Meter (MID Certified) MID

ma output signal with transmitter module. - Adjustable frequency output signal with pulse divider module

ENGLISH. Stock N o Stability indicator Light on/ Dark. on optional Output can be

INDUSTRIAL+COMMERCIAL ZMD310AT/CT TECHNICAL DATA. Measurement Accuracy. Measurement Behaviour. MID-specific data. Current (for Class B) General

Single phase meter with direct connection and pulse or Modbus RS485 output

Energy Management Energy Meter Type EM110

M70LL Laser Distance Sensor

E550 Series 2. Electricity Meters IEC/MID Industrial and Commercial ZMG400AR/CR. Technical Data

Supercal 531 Multi function Integrator that lives up to Your highest expectations

ULTRAHEAT / ULTRACOLD T330. The Evolutionary. Ultrasonic Heat Meter / Cooling Meter. Ultrasonic Heat Meter / Cooling Meter.

E l e c t r o m a g n e t i c f l o w m e t e r s

J Series induq VMZ MAGNETIC INDUCTIVE FLOW SENSORS. DB_Magnetic_Inductive_Flow_Sensors 05/2016

ULTRAHEAT / ULTRACOLD T330. The Evolutionary. Ultrasonic Heat Meter / Cooling Meter. Ultrasonic Heat Meter / Cooling Meter.

Near Infrared Light Ring Series OPA80 and OPA83 Series

QL50 Luminescence Sensor

M.3. Electrical measurement and control. Electrical energy meters for partial consumption

Incremental encoders Redundant sensing, isolated blind hollow shaft ø mm, cone shaft ø17 mm pulses per revolution

Technical data. General specifications. Measurement range min max. 360

Energy Management Energy Meter GM3D

SVM F22. Calculator for heating or cooling applications. Data sheet

EN-2018 MAGNETIC FLOW METERS

MULTICAL Energy meter TS PTB. Application

Transcription:

APPLICATION Fully electronic bulk water meter for measuring the flow (cold water up to 30 C) in supply lines with high flow at low pressure loss. Highly accurate recording of all billing data. FEATURES 4 Calibratable and exchangeable measuring insert 4 Electronic sensor control for recording flow rate 4 Lithium battery, lifetime up to 12 years 4 Optical ZVEI interface equipped as standard 4 Adjustable reading date for billing 4 Rotatable integrator 4 Single-line 7-digit display for easy meter reading 4 For horizontal and vertical installation

ELECTRONIC - BASIC FEATURES Ambient class OIML R49 class C / MID E2 + M1 Protection class IP 54 or IP 68 Interfaces standard Optical ZVEI Interfaces optional* M-Bus, L-Bus, pulse * Possible combinations - M-Bus / pulse - L-Bus / forward pulse - only M-Bus Note: HYDRO-SET Software for configuration of meters, readout of measured values and printout of meter logs. Available under www.diehl.com/metering (Products - downloads) DISPLAY Display indication LCD, 7-digit Unit m³/h - l/h - m³ - l Total values 9,999.999-999,999.9-99,999.99-9,999.999 Values displayed Flow rate VOLUME - / PULSE OPEN COLLECTOR Max. frequency Hz 90 Max. input voltage V 30 Max. input current ma 27 Max. voltage drop at active output V/mA 2/27 Max. current through inactive output μa/v 5/30 Max. reverse voltage without destroying outputs V 6 Pulse duration ms 5.5 Min. pulse pause ms 5.5 SUPPLY VOLTAGE Operating voltage UN VDC 3.0 (lithium battery) Battery lifetime Up to 12 years Nominal power PN μw 30 INTERFACES - OVERVIEW Optical ZVEI interface for communication, M-Bus protocol M-Bus According to EN 1434-3. Data reading and parametriziation are via two wires with polarity reversal protection. L-Bus Interface for the radio module IZAR RADIO EXTERN Pulse Output for volume (open collector) 18.03.2015 2

PULSE INTERFACE - SPECIFICATION DN 50-125 Pulse rates l/pulse Decadic 1... 1000 DN 50-125 Display 1 digit after comma DN 50-125 Pulse value 1 l/pulse 1 (factory setting) DN 50-125 Pulse value 2 l/pulse 100 (factory setting) DN 150 Pulse rates l/pulse Decadic 10... 10000 DN 150 Display 0 digits after comma DN 150 Pulse value 1 l/pulse 10 (factory setting) DN 150 Pulse value 2 l/pulse 1000 (factory setting) Pulse variants Two forward pulses; one forward and one backward pulse; pulse and direction signal 18.03.2015 3

GENERAL Temperature range C 0... 30 Temperature safety C 0... 50 Ambient operating temperature C 0... 55 Ambient storage temperature C 0... 55 Nominal pressure PN bar 16* * Special versions on request TECHNICAL DATA Nominal diameter DN mm 50 65 80 100 125 150 Permanent flow rate Q 3 m³/h 40 63 100 160 160 - Minimum flow rate Q 1 m³/h 0.63 0.63 1 1.6 1.6 - Transitional flow rate Q 2 m³/h 1.02 1.01 1.6 2.56 2.56 - Overload flow rate Q 4 m³/h 50 78.75 125 200 200 - Nominal flow rate (DIN ISO 4064) Q n m³/h 15 25 40 60 100 150 Minimum flow rate horizontal Q min m³/h 0.35 0.45 0.5 0.6 0.6 1.8 Minimum flow rate vertical Q min m³/h 0.4 0.5 0.5 0.6 0.6 1.8 Transition flow rate horizontal Q t m³/h 1 1.2 0.8 1.8 2 4 Transition flow rate vertical Q t m³/h 1.8 2 0.8 1.8 2 4 Maximum flow rate (short-term) Q max m³/h 90 120 200 300 350 350 Starting flow rate l/h 90 130 160 190 190 1500 Flow rate at 0.1 bar pressure loss m³/h 35 63 115 115 105 310 Pressure loss at Q 3 bar 0.25 0.16 0.25 0.4 0.4 - Nominal diameter DN mm 200 250 300 400 500 Permanent flow rate Q 3 m³/h - - - - - Minimum flow rate Q 1 m³/h - - - - - Transitional flow rate Q 2 m³/h - - - - - Overload flow rate Q 4 m³/h - - - - - Nominal flow rate (DIN ISO 4064) Q n m³/h 250 400 600 1000 1500 Minimum flow rate horizontal Q min m³/h 4 12 18 30 45 Minimum flow rate vertical Q min m³/h 4 - - - - Transition flow rate horizontal Q t m³/h 6 20 50 50 80 Transition flow rate vertical Q t m³/h 6 - - - - Maximum flow rate (short-term) Q max m³/h 650 1200 1500 2800 4200 Starting flow rate l/h 2500 5000 10000 15000 20000 Flow rate at 0.1 bar pressure loss m³/h 550 800 1250 3000 6000 Pressure loss at Q 3 bar - - - - - 18.03.2015 4

APPROVAL Nominal diameter DN mm 50 65 80 100 125 150 National 6.132 / 92.08 6.132 / 92.08 6.132 / 03.20 6.132 / 03.20 6.132 / 03.20 6.132 / 03.21 Metrological class B H B H B B B B MID (DE-13-MI001-PTB005) - Dynamic range (Q 3/Q 1) R* 63 H 100 H 100 100 100 - Nominal diameter DN mm 200 250 300 400 500 National 6.132 / 03.21 6.132 / 06.24 6.132 / 06.24 6.132 / 92.07 6.132 / 92.07 Metrological class B B B B B MID (DE-13-MI001-PTB005) - - - - - Dynamic range (Q 3/Q 1) R* - - - - - * Standard dynamic other dynamics on request 18.03.2015 5

DIMENSIONS Nominal diameter DN mm 50 65 80 100 125 150 Overall length L mm 200 / 300 1 200 200 1 / 225 / 350 1 250 / 350 1 250 300 Flange diameter D mm 165 185 200 220 250 285 Hole circle diameter PN 10 / PN 16 K mm - / 125 - / 145 160 / 160 - / 180 - / 210 - / 240 Number of screwholes PN 10 / PN 16 pcs - / 4 - / 4 4 / 8 - / 8 - / 8 - / 8 Screwhole diameter PN 10 / PN 16 D1 mm - / 18 - / 18 18 / 18 - / 18 - / 18 - / 22 Height H mm 75 83 89 105 115 135 Height H1 mm 123 123 154 154 154 245 Height to remove measuring insert mm 225 225 275 275 275 475 Meter width mm 155 155 200 220 250 285 Diameter Ø B mm 110 110 110 110 110 110 Weight kg 10.2 11.2 13 13 21.5 39 Nominal diameter DN mm 200 250 300 400 500 Overall length L mm 350 450 500 500 500 Flange diameter D mm 340 405 460 580 715 Hole circle diameter PN 10 / PN 16 K mm 295 / 295 350 / 355 400 / 410 515 / 525 620 / 650 Number of screwholes PN 10 / PN 16 pcs 8 / 12 12 / 12 12 / 12 16 / 16 20 / 20 Screwhole diameter PN 10 / PN 16 D1 mm 22 / 22 23 / 27 23 / 27 27 / 30 27 / 33 Height H mm 163 193 230 290 360 Height H1 mm 245 242 290 311 361 Height to remove measuring insert mm 475 472 520 580 660 Meter width mm 340 405 460 580 715 Diameter Ø B mm 110 110 110 110 110 Weight kg 47 75 165 190 300 1 : Special body lengths on request SPECIAL VERSIONS - Versions with different nominal pressure on request - Flange for ANSI and BS on request - CuZn parts in V2A on request - Temperature up to 90 C on request - Special pulse values on request 18.03.2015 6

PRESSURE LOSS GRAPH / TYPICAL ERROR GRAPH Pressure loss graph Typical error graph 18.03.2015 7