Instruction Manual TABLE OF CONTENTS 1 PRINCIPLE OF OPERATION Limitations INSTALLATION Mains connection...

Similar documents
FLOMID-MX Control unit for electromagnetic flowmeters USERS MANUAL. instrumentación para fluidos. Realitzat: Revisat R+D Electrònic: Aprovat: Data:

Ultrasonic level transmitter Series LU Instructions Manual

Level gauges Series LT Level indicator, switch and transmitter for liquids

Target disk flowmeters Series DP Metallic flowmeter for liquids and gases

SC-FI Series Frequency to Current Signal Conditioner

INSTRUCTION MANUAL MODEL 2455T SUBCARRIER MODULATOR

TIM-018 Mk2. London Electronics Limited. Triple output loop splitter. Connection details and general information

Data Acquisition Modules/ Distributed IO Modules

INSTRUCTION MANUAL MODEL 2779 SUBCARRIER MODULATOR

3 PHASE ENERGY ELECTRONIC METERS MKT & MKT2. (Code to ) INSTRUCTION MANUAL ( M / 00 A ) (c) CIRCUTOR S.A.

INSTALLATION AND OPERATING INSTRUCTIONS MODEL SIVF. KB Part No Signal Isolator for KBVF Controls. See Page 1 Pending

TLS-A. Laurel Electronics, Inc. Triple output loop splitter. Connection details and general information

FREQUENCY => CURRENT / VOLTAGE CONVERTER Z111

Current consumption ma solenoid current consumption ( max 300 ma) Hz % V ma. Housing dimensions mm 120(d) x 99(h) x 23(w)

PEAKTRONICS AMI-103. AC Motor Interface AMI-103 AMI-103A AMI-103B FEATURES

MODEL AT-10 ANALOG TRANSMITTER

Section 1, General information Introduction... 3 Description... 3 Specifications... 4 Wiring connections... 5

TMP-100 Turbine Meter Pulse Divider Circuit

22 Series Relays. Technical Data...1. Specifications...2. Model Number Structure - Relays...3. Model Number Selection

CONTENTS XV300K GB r doc XV300K 2/13

Series BDF for Process

Series 500. Owner s Manual. Analog Transmitters by Data Industrial. Data Industrial. Data Industrial 2/95 PN 72806

Installation and Operating Manual

SYNCHRONISM RELAY SYNCRO-96. (Code ) INSTRUCTION MANUAL ( M / 99A ) (c) CIRCUTOR S.A.

Operating Instructions. for. Controller SMS 160 / 161

INSTALLATION & OPERATION MANUAL

E7000, E7500, and E ma Analog Transmitters

Thermocouple - Transducer

FLOMID FX Electromagnetic Flowmeter

DUAL OUTPUT AC CURRENT/VOLTAGE TRANSDUCER

20 Series Power Relays

Programmable Universal Frequency Transducer

Model 805 PWM Proportional Valve / Solenoid Driver with Peak and Hold Control Modes

Model FLSC-C3-XX. DC Powered Microprocessor Controlled Transmitter

DT1100 E xx xx (PS) Galvanic Isolators. Operating Instructions

DT1100 xx xx xx PS. Isolators, Isolator / Power Supplies. Operating Instructions

Installation, Operation and Maintenance Manual

WRM-10 TM TRANSFORMER WINDING RESISTANCE METER

SI-125 Power Amplifier Manual 6205 Kestrel Road; Mississauga, Ontario; Canada; L5T 2A1 November 2016, Rev 0.5

RENATO DESIRÒ PARABIAGO (MI) Via Sant Anna, 51 Tel Fax

O. S. WALKER MICROPROCESSOR CHUCK CONTROL MODEL MSB SERIES TABLE OF CONTENTS

Digital Panel Meter K3TE. Model Number Structure. Model Number Legend. Easy-to-use, Low-cost Digital Panel Meter that Accepts DC Input K3TE

User's Manual PDO 2035

INSTALATION, OPERATION & MAINTENANCE MANUAL. PA-1001A Series SIGNAL CONDITIONER & CONVERTORS

FIELD MOUNTED RATE TOTALISER MODEL 202D

Pulse Scaler for DIN Rail Attachment

User's Manual: Series 350T AC Current Input (External Sensor), DC-Powered Transmitters

Ametek, Inc. Rotron Technical Products Division. 100 East Erie St., Suite 200 Kent, Ohio User's Guide. Number Revision F

PROMUX Distributed MODBUS I/O Modules Catalog and Design Guide

Operating Instructions. for. Controller SMS 150 / 151

FREQUENCY-CONVERTER MFR 600A / 1500A Version 2

Power supply CP-D 24/4.2 Primary switch mode power supply

User's Manual: Series 450T AC Current Input (External Sensor), AC-Powered Transmitters

Technical Manual TRANSDUCER AMPLIFIER TYPE DR7AC. Doc. Ref CD2402K

PULSE TRANSDUCER K816 / IWe2. Operating Instructions

Product Manual 5202 Pulse isolator

Signal converter for electromagnetic flowmeters

Installation, Operation and Maintenance Instructions

CONTA-ELECTRONICS. Converter Units

Proportional amplifier type EV22K5

Power supply CP-E 24/2.5

BLD75-1. Bilevel Step Motor Driver. User s Guide. #L010125

American Power Design, Inc.

D.C. BRUSHLESS MOTORS DRIVE. BLD07-IT Service Manual

Power supply CP-D 12/2.1

Rev /13 SSRMAN-1B SERIES USERS MANUAL SSR INTELLIGENT BURST FIRING CONTROL COPYRIGHT 2013 NUWAVE TECHNOLOGIES, INC.

Operating Manual * * Differential pressure transmitter. Table of Contents. 1 Safety guidelines. 1.1 General Information

Ambient Conditions. Operating Conditions. Pressure

Copyright 2014 by Minarik Drives

ECM3 EARTH CONTINUITY RELAY

Proximity Sensor Terminology

PROXIMITY SENSOR TERMINOLOGY

BROADBAND LINEAR AMPLIFIER Model P150

POWER TRANSDUCERS ACTIVE AND REACTIVE SERIES: T-W WATT T-V VAR

10 Amp Digital PWM Motor Speed Controller CV-2110-HD and CV-2110-HDS

Technical Documentation

Technical Manual Modulation Box

DUAL CHANNEL BROADBAND LINEAR AMPLIFIER Model A800D

Efcon Water. Installation & User Manual Electro Magnetic Flowmeter (EMF) Efcon Water compact Electro Magnetic Flowmeter (EMF) Manual Version UK

PROMUX Distributed MODBUS I/O Modules Catalog and Design Guide

IOM. Model 1050 Strain Gage Transmitter Installation & Operation Manual. (Cage Code #1MU21)

Specification for Lightning Sensor

Quick Start Guide. ELPRO 905U-L-T Wireless I/O Transmitter Unit. man_905u-l-t_quickstart_v1.9.doc

USER S MANUAL PROCESS CONTROL MODULE PCM3

Industrial Systems Design & Implementation

T6+ Analog I/O Section. Installation booklet for part numbers: 5/4-80A-115 5/4-90A-115 5/4-80A /4-90A-1224

SDI SPECTRADYNAMICS, INC. LOW NOISE FREQUENCY REFERENCE OPERATING MANUAL

GTT 25A - 40A - 60A - 90A - 120A POWER SOLID STATE RELAYS WITH ANALOG CONTROL

D7F. Detects Changes in Machine. Vibration. Vibration Sensor with Linear Output or Manual Setting. Ordering Information

Power supply CP-D 24/1.3

Meter Bus Application ANALOG-BOARD Revision 5.1

Cable Identifying Generator LCI TX / LCI TX-440

Disc Gap Control DGC-2. Technical Manual

Ocean Controls KT-5221 Modbus IO Module

Operating Instructions

Service Instructions. The Conductor Controls. Conductor DC15-A, Enclosed Unit CH15-A, Open Chasis Unit

Z-10-D-IN. RS485 Modbus Module 10 Digital Inputs

An American Control Electronics Brand PCM4 SERIES USER MANUAL PCM4.

Switching power supplies CP range, Linear power supplies CP-L range. Content

MCR-VAC-UI-0-DC. Voltage transducer for AC voltages. INTERFACE Data sheet _en_02. 1 Description

Transcription:

instrumentación para fluidos CI- pulse / ma Converter Instruction Manual TABLE OF CONTENTS PRINCIPLE OF OPERATION.... Limitations.... INSTALLATION.... Mains connection........ Input connection........ Pick-up input..... Electrical contact input.... Analog output connection.... Pulse output connection... SETTING UP. CONFIGURATION... TECHNICAL CHARACTERISTICS.... Working conditions...... Mains supply...... Analog output... Pulse inputs....... Pulse output... Norms...... Dimensions... R-MI-CI Rev.: English Version

PRINCIPLE OF OPERATION The CI- converter has been designed to generate an analog output which is proportional to the input frequency and at the same time an opto-isolated pulse output the same as the input. All the mathematical functions are made by a microprocessor that also filters the output to give a stable reading. The relationship between the current output and the input frequency is: I o = Output current I i = Initial Current (Beginning of the Scale) I r = Current range f e = Input Frequency Io = f r = Full Range Frequency (Frequency for maximum output) Ii + I r x f f e r The value of I i (Initial Current) and I r (Current range) are selected by means of two jumpers inside the instrument. The values of these currents for the beginning and full scale are: Beginning of Scale I i Full Scale Current Range I r ma ma ma ma ma ma By means of another two jumpers the current output can be changed for voltage outputs to obtain the following voltage outputs: Beginning of Scale Full Scale V V V V V V V V The value of f r (the full scale frequency) is selected by means of four BCD switches below the front panel. Four jumpers are provided to select the decimal point position.. Limitations The minimum frequency that the instrument will detect is, Hz (one pulse every seconds). The maximum input frequency is. Hz.. INSTALLATION The CI- is housed in an IP plastic case for mounting on a panel inside an electric control panel. The plastic case has two holes for mounting with screws to DIN and DIN, and also it has a snap fastener for fitting to DIN and DIN EN assembly rails. Screw terminals are provided for the external wiring. The terminals are protected against accidental contact in accordance with VDE Part, VDE Part and VBG.. Mains connection The mains supply voltage is connected to terminals and. The mains voltage is indicated on the label at the side of terminals &.

IMPORTANT : In order to comply with the safety requirements as per IEC -, a mains switch must be provided to disconnect the equipment. This switch must be marked as the disconnecting device for the equipment and be within easy reach of the operator. The equipment must be installed inside an electrical mounting cabinet to avoid the possibility that the operator may touch a connection terminal.. Input connection The CI- is designed to be able to work with two types of inputs... Pick-up Input For the input from turbine type flowmeters which use magnetic inductive pick-ups to detect the movement of the turbine blades, the wiring must be made as following: CI- Terminal N o. Pick-up Terminal N o. shield shield live live live live "live" means the two ends of the pick-up coil. The input cables must not be installed close to mains cables as these can induce errors due to electrical interferences... Electrical contact input For connecting inputs from reed switches etc., as one can find for example in COVOL flowmeters, the wiring must be made as following: CI- Terminal N o. COVOL Terminal N o. shield shield no connection live live

The shield is connected to one end of the reed switch and the live to the other end. A pulse generator with an open collector output (NPN transistor) can be connected to this input mode. In this case the emitter (or common) must be connected to terminal and the collector to terminal.. Analog Output Connection The analog output connected to terminals and. Terminal is the positive of the output and terminal is the negative (common). When the instrument is used for a current output then the load applied to the output should be less than ohms. When the instrument is used for a voltage output then the load applied to the output should be greater than, ohms.. Pulse output connection Terminal is the emitter of an optoisolated NPN transistor and terminal is the collector. This output can be used to activate electromagnetic units such as DC counters or relays. No protections for excess current or voltage spikes are provided. These should be installed externally as required. CI- + V Input Connection to a PLC with a "PNP" input V Example of connection to a PLC PLC. SETTING UP Once the instrument is installed the only thing that has to be done is setting the frequency which must de applied to the input frequency to obtain the full scale analog output. To introduce this frequency we have four BCD coded switches and a jumper with four positions. With the four BCD coded switches we select the four significant digits and with the jumper we select the position of the decimal point. To get to the switches, a screwdriver can be used to lever out the top cover, which is just clipped in its place. The jumper must be in one of the four positions provided. The instrument will not work correctly if the jumper is not in one of the four positions. Frequency =, Hz Frequency =, Hz Frequency =, Hz Frequency = Hz

In the examples given, the jumper is shown as a black filling. In the four examples we can see how to program the frequency which corresponds to the maximum output. When changing the maximum frequency, this should be done with the instrument disconnected from the mains supply. The instrument reads the switch data only when it is switched on.. CONFIGURATION It is not normally necessary for the user to have to change the basic configuration of the instrument, given that the CI- is supplied according to the clients specifications. In the example given the instrument is configured for a COVOL input and - ma output. The JP and JP jumpers are used to configure the type of input and should not be moved The jumpers JP, JP, JP & JP are used to configure the type of output. Beginning Full JP JP JP JP of Scale Scale. ma ma X X. ma ma X. V V X X X X. V V X X X. V V X X X. V V X X Jumpers JP and JP are used only for voltage outputs, and have only one position. Jumper JP fixes the full scale range. Jumper JP is used to determine the beginning of the scale and has two positions, "" towards the top of the PCB and "" towards the bottom of the PCB. The jumpers should be placed in the position marked with "X". The potentiometer POT can be used for fine adjustment of the full scale reading.

. TECHNICAL CHARACTERISTICS. Working conditions The case has a protection as per IP and the terminals as per IP. The working temperature limits are to o C. Mains supply The standard mains voltage is Vac / Hz. AC Mains voltages of V, V y V / Hz. and Vdc supply voltage are available on order. The power consumption is less than W. The instrument is not supplied with a mains filter and in the exceptional cases that, due to high levels of mains interference, a mains filter is needed, this must be installed externally. Due to the low power consumption, almost any small mains filter will be adequate. The instrument is supplied with a slow blow (T) ma fuse.. Analog Output The analog output is configured internally for current or voltage output. Current Output - Maximum Load = ohms Voltage Output - Minimum Load =. ohms. Pulse inputs. The input called "COVOL" is designed to work with an electrical contact which closes the circuit between terminals and of the terminal strip. Given that this type of input is generally slow and to avoid contact bounce, this input is limited to about pulses per second.. The pick-up input is designed to work with an inductive pick-up using a coil. The input frequency in this case is limited to about, pulses per second.. Pulse Output Frequency : The same as the input frequency (max. Hz). The opto isolated open collector has the following characteristics: NPN Transistor Maximum Voltage : Vdc Maximum Current : ma. Norms Conforms with Directives //CEE (EMC) and //CEE (Low voltage)

. Dimensions In the following drawings the outside dimensions and the layout of the fastening holes for screws are given. The layout of the fastening holes is given looking at the top of the instrument. The weight of the instrument is approximately g

WARRANTY Tecfluid S.A. GUARANTEES ALL ITS PRODUCTS FOR A PERIOD OF MONTHS, after consignment, against all defects in materials and workmanship. This warranty does not cover failures which can be imputed to misuse, use in an application different to that specified in the order, the result of service or modification by un-authorized persons, bad handling or accident. This warranty is limited to cover the repair or replacement defective parts which have not been damaged by misuse. This warranty is limited to the repair of the equipment and all further and eventually following damages are not covered by this warranty. Any consignment of equipment to our factory or distributor must be previously authorised. The consignment should be done with the equipment well packed, clean of any liquids, grease or hazardous materials. Tecfluid S.A. will not accept any responsibility for damage done during transport. Together with the equipment, a note should be enclosed indicating the failure observed, the name, address and telephone number of the sender. TECFLUID, S.A. Narcís Monturiol, E- Sant Just Desvern Tel. + - Fax + E-mail: tecfluid@tecfluid.com Internet: www.tecfluid.com The technical data in this pamphlet is subject to modification without notification, if the technical innovations in the product or manufacturing processes so require.