OPC-E1-PG3 Specifications

Similar documents
PG Interface Card "OPC-E1-PG"

PG Interface Card "OPC-E1-PG"

[ 4 ] Using pulse train input (F01 = 12)

QUICK GUIDE PUMP CONTROL. High performance Compact Inverter. Date Version 22/09/

(Supplement to Instruction Manual)

General Specifications FECA-TE /2010. Phone: Fax: Web:

6.9 Jump frequency - Avoiding frequency resonance

FUJI Inverter. Standard Specifications

TOSVERT TM VF-nC3 Parameter List

PG Interface Card "OPC-E2-PG"

VFS11 Parameter List for up to CPU version 105

ROLL TO ROLL FUNCTION MANUAL FR-A (0.4K)-04750(90K)-R2R FR-A (0.4K)-06830(280K)-R2R FR-A (315K)-12120(500K)-R2R

HPVFP High Performance Full Function Vector Frequency Inverter

Digital Input/Output Interface Card "OPC-DIO"

AV-300i Specifications. Saftronics Inc. VG10 Product Specifications VG10. Dynamic Vector Drive

TECO F510 Inverter. Quick Start Guide. Step 1. Supply & Motor connection

General Specifications

GS1 Parameter Summary Detailed Parameter Listings...4 9

Multi-function, Compact Inverters. 3G3MV Series

HITACHI. L100-M Series Inverter Quick Reference Guide. Hitachi Industrial Equipment Systems Co., Ltd. Single-phase Input 100V Class

PG Interface (5 V Line Driver) Card "OPC-G1-PG22"

VFD - D700 Series Specifications. The latest low-cost variable speed control solution for centrifugal pumps.

SJ100 Series Inverter Quick Reference Guide. Single-phase Input 200V Class Three-phase Input 200V Class Three-phase Input 400V Class

TOSVERT VF-AS1 My Function Instruction Manual

V&T Technologies Co., Ltd. Vectorque TM V6-H-M1 SERIES INVERTER ADDITIVE MANUAL (M1) V6-H Series ADDITIVE MANUAL V& T

PSF-520 Instruction Manual

Multifunction Keypad OP-KP-LCD. Multi-function Keypad with LCD & LED display for programming IMO Jaguar Inverters.

CHAPTER 8 PARAMETER SUMMARY

AF-300 G11 Specifications. GE Industrial Systems. Product Specifications AF-300 G11

Index 2. G Gain settings 4 31 Glossary of terms A 2 Grommets 2 13

QUICK GUIDE PUMP CONTROL. Frequency inverter for pump control and HVAC applications. Date Version 22/09/

CHAPTER AC DRIVE PARAMETERS. In This Chapter...

Hitachi P1 Closed Loop Hoist Basic Instruc on Manual

Caution. Three-phase 400V series FRN0.4C1S-4A FRN0.75C1S-4A FRN1.5C1S-4A FRN2.2C1S-4A FRN3.7C1S-4A

VS-616G5 Series (Revision F) Programming Manual. Constant Torque Inverter with Adaptive Vector Control (AVC )

MEGA Servo setup procedure for driving PMS motor

CHAPTER 8 SUMMARY OF PARAMETER SETTINGS

α α Retry count clear Alarm reset Active End of retry S-curve time during accelerati on H04: (Count) setting S curve time during decelerati on

Digital Interface Option "OPC-E1-DIO"

FRN E1-4LM FRN E1-7LM

QUICK GUIDE SINGLE PUMP CONTROL. Frequency inverter for pump control applications SG_PUMP_CONTROL_HVAC_EN_1.1.0

CHAPTER 5 DESCRIPTION OF PARAMETER SETTINGS

QUICK GUIDE PUMP CONTROL. Frequency inverter for pump control and HVAC applications. Date Version 24/10/

vacon nx all in one application manual ac drives Phone: Fax: Web: -

Troubleshooting 12. This section explains the items to check when problems occur, and troubleshooting by the use of error displays or operation state.

No Gain Tuning. Hunting. Closed Loop System

Series Concepts. Ideal functions to meet various needs. New, compact design. Simple operation. Flexible through optionals

AZ Series. Function Edition. Closed Loop Stepping Motor and Driver Package. Operation. I/O signals. Parameter

Connection and Operation

Before you operate the inverter, the parameters that you must first program are the basic parameters.

CHAPTER 5 DESCRIPTION OF PARAMETER SETTINGS

AV-300i Specifications. Saftronics Inc. PC10 Product Specifications PC10. Mini Vector AC Drive

Variable Frequency Drive / Inverter (0.4 ~ 280kW)

For more information on these functions and others please refer to the PRONET-E User s Manual.

Quick Reference Guide. DF5-... Frequency Inverters 02/02 AWB GB

NX series Constant and variable torque Variable Speed Drives for induction motors

Copyright 2014 YASKAWA ELECTRIC CORPORATION All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or

CTi Automation - Phone: Fax: Web: -

VF-nC1 Adjustable Speed Drive Engineering Specification

Series Concepts. Ideal functions to meet various needs. New, compact design. Simple operation. Flexible through optionals

Operating Instructions

ADJUSTABLE SPEED DRIVES. AS1 Drive

MD310 Quick Start Manual. General-Purpose AC Drive

CHAPTER KEYPAD OPERATION AND QUICKSTART. In This Chapter... The GS2 Digital Keypad GS2 Quickstart...3 6

VFS9 Parameter List for Version110 or later

New FUJI ELECTRIC INVERTERS

13. Before making a service call Trip information and remedies

MA7200 PLUS INVERTER SERIES PID Quick Start Manual For Fan and Pump Applications

TOSVERT VF-AS1 PID control Instruction Manual

Application Note: Replacing J300 with SJ300 Series Inverters

S11 Adjustable Speed Drive Engineering Specification

EDC Quick Start Guide

Troubleshooting Alarm Displays Warning Displays

Year. Caution. Index. 2 Features. 5/6 Range and Application. 7 Other Features. 8 Specifications. 12 Terminal Functions

Compact & Powerful Inverter STARVERT ig5a 0.4~1.5kW 1phase 200~230Volts 0.4~22kW 3Phase 200~230Volts 0.4~22kW 3Phase 380~480Volts

LX3V-4PG User manual Website: Technical Support: Skype: Phone: QQ: Technical forum:

3. Be aware of the ambient temperature. Use the unit within the specified ambient temperature only.

Max. sp Min. spe Negativ speed s Synchro out speed refere selection Menu 13. g t x (-1) UMV 4301

TRANSISTORIZED INVERTER -INSTRUCTION MANUAL- ORIENTATION CONTROL / ENCODER FEEDBACK CONTROL / PULSE TRAIN INPUT FR-A5AP

user's manual nx frequency converters beam pump application asfiff13

Speed Feedback and Current Control in PWM DC Motor Drives

Copyright / Trademarks -This manual and its contents are copyrighted. -You may not copy this manual,in whole or part,without written consent of

TECHNICAL BULLETIN. Thank you for your continued support of Mitsubishi programmable logic controllers, MELSEC-A series.

Jaguar Motor Controller (Stellaris Brushed DC Motor Control Module with CAN)

Advanced user guide. Commander SX. IP66/Nema 4X AC Variable Speed Drive en / a. Part Number :

ADJUSTABLE SPEED DRIVES FS1

Enhanced PID for Air Compressors F7 Drive Software Technical Manual

INDEX. i 1. B Braking Resistor Dimensions: A 24 Braking Resistors: A 20 Braking Units: A 20. DURAPULSE AC Drive User Manual

NX Series Inverters. HVAC Pocket Programming Guide

Dual-inverter Wire Drawing Machine CHV130 series Frequency inverter Operation manual

In the event of a failure, the inverter switches off and a fault code appears on the display.

$MPTFE -PPQ 4UFQQJOH 4ZTUFN.JOJBUVSJ[FE $PNQBDU 4J[F $MPTFE -PPQ 4ZTUFN /P (BJO 5VOJOH /P )VOUJOH )JHI 3FTPMVUJPO 'BTU 3FTQPOTF

Series Concepts -'0+ ) 1!!!! $ ( $ $ # $ 2 ( $!! $ #!! $! $ ( $! # # $ $ 2 3 $! 45 (. ( ) / # 6 $( $ * &7 89 : $ ')8;" : - 2 -

General Specifications

E3 Adjustable Speed Drive Engineering Specification

Invertek Optidrive E3 Frequency Inverter (IP20, 3ph output) Easy Start Guide

Quick Reference Guide. DF5-... Frequency Inverters 02/02 AWB GB. For Immediate Delivery call KMParts.com at (866)

STEPPING MOTOR EMULATION

Latest Control Technology in Inverters and Servo Systems

FRENIC MEGA in Injection Moulding Machine s applications

Transcription:

OPC-E1-PG3 Specifications Power Electronics Business Group Drive Division Development Dept. b DATE NAME APPROVE a DRAWN 2006-06-05 O. Mizuno CHECKED 2006-06-06 T. Ichihara K. Fujita Fuji Electric Co., Ltd. b Dwg. No. SI27-4391 1/20 b Dwg. No. SI27-4391b 1/20

1. Summary of the functions Mounting this optional card into your FRENIC-Multi inverter enables speed control with PG (e.g. V/f control with PG and dynamic torque vector control with PG), pulse train input and positioning control. 1.1. Applicable CPU Number OPC-E1-PG3 can be used in an inverter with a CPU number listed in Table 1-2. Table 1-1. Applicable CPU Numbers Inverter Series Type Inverter Capacity Inverter CPU Number FRENIC-Multi FRN E1 - ALL 0800 or later 1.2. Applicable PG The specifications of PG are showed in the Table 1-2. Applicable PG Items Number of output pulse PG power supply Output pulse type Table 1-2. Applicable PG Specifications 360~3000 20 to 3600P/R b A,B Phase (incremental) Z phase +12V±10%/80mA or +15V±10%/60mA Open collector (Wire length 30m or less(30khz)) Push pull (Wire length 30m(100kHz) /100m(30kHz) or less) PG power +12V±10%/80mA or +15V±10%/60mA Internal power supply supply (Select by switch) 1.Use PG which power supply specification matches the specification showed in the table above. 2. Terminal explanation 2.1. Terminal arrangement The terminal arrangement is showed Fig.2-1. For the explanation of the terminals showed in upper section in Fig.2-1,refer to the inverter instruction manual (Chapter 2). Note: Terminal "PLC" can output power supply only for digital input terminals when digital input terminals are used as source logic. CMY Y1 Y2 C1 FM 11 11 12 13 CM FWD REV X1 X2 X3 X4 X5 PLC CM YA YB YZ PO PI Fig.2-1. Terminal arrangement Dwg. No. SI27-4391b 2/20

2.2. Explanation of terminal function The terminal functions are described in Table2-1. Table2-1. Terminal functions Symbol Terminal name Terminal function PI External power supply input Power input terminal from the external device PO Power supply output Power output terminal Select 12V or 15V by SW3 on option card. 12V 15V (factory default) 12V 15V 12V 15V CM Common Common terminal for power supply and PG input Pulse input terminal for commands or feedback YA YB YZ A phase pulse input Y B phase pulse input Y Z phase pulse input Y [Use as commands] To supply speed commands from the pulse train generator or PG, connect an open-collector output signal or complementary output signal to these terminals. Since [YZ] is not used for train input control, connection to [YZ] is not required if there is no corresponding output at the PG. In positioning control, however, connection to [YZ] enables positioning correction. [Use as feedback] These terminals are for the detection of the inverter-driven motor speed. Connect an opencollector output signal or complementary output signal to these terminals Since [YZ] is not used for speed control, connection to [YZ] is not required if there is no corresponding output at the PG. In positioning control, however, connection to [YZ] enables positioning correction. Note: Incorrect wiring of A/B phase could fail to run the motor normally or cause an inverter trip. Dwg. No. SI27-4391b 3/20

2.3. Wiring diagram 2.3.1. For Frequency Control with Pulse Rate Input Fig.2-2 shows connection diagram examples for frequency control with pulse rate input. When using inverter internal power supply When using external power supply FRN-E1S L1/R U L2/S V L3/T W M FRN-E1S L1/R U L2/S V L3/T W M G G OPC-E1-PG3 OPC-E1-PG3 PI PO YA YB YZ CM Pulse train generator PG or PG PI PO YA YB YZ CM Pulse train generator PG or PG 12Vdc ±10% or 15Vdc±10% Fig.2-2. Connection Diagrams for Frequency Control with Pulse Rate Input 2.3.2. For Speed and Positioning Controls Fig.2-3 shows connection diagram examples for speed and positioning controls. When using inverter internal power supply When using external power supply FRN-E1S L1/R U L2/S V L3/T W M FRN-E1S L1/R U L2/S V L3/T W M G G OPC-E1-PG3 OPC-E1-PG3 PI PO YA YB YZ CM PG PI PO YA YB YZ CM PG 12Vdc ±10% or 15Vdc±10% Fig.2-3. Connection Diagrams for Speed Control with PG and Positioning Control Dwg. No. SI27-4391b 4/20

3. Frequency Control with Pulse Rate Input The pulse rate input feature supplies a frequency command to the inverter in pulse trains. Two pulse input modes are available--b phase pulse (with signs) and forward/reverse rotation pulse trains. OPC-E1-PG3 can't be used as speed control and pulse rate input concurrently. 3.1. Specifications Table3-1 lists the specifications of frequency control with pulse rate input. Table3-1. Specifications for Pulse Train Inputs Item Specifications Reference frequency range 0 to 400 Hz Frequency accuracy ±0.2% of maximum frequency Output circuits Open collector Complementary Input pulse level 12 VDC ±10% or 15VDC ±10% Maximum cable length and maximum input pulse rate Open collector : 30m / 30kp/s Complementary : 30m / 100kp/s or 100m / 30kp/s 3.2. Terminal Functions Table3-2 lists terminal specifications. Terminal symbol PI 3.3. Block diagram Name Power input terminal Table3-2. Terminal Specifications Descriptions Receives power for the PG from an external source. PO Power output terminal Outputs power to the PG. CM Common terminal Common terminal for the PG power. YA Command input terminal for A phase pulse train Receives an A phase command pulse train. YB Command input terminal for B phase pulse train Receives a B phase command pulse train. YZ -- Reserved. Fig.3-1 shows a block diagram of the pulse train input command system. [YA] [YB] o01 Input mode Frequency measurin g Pulse count factoring o08 o07 o06 UP/DOWN keys on keypad [12] Frequency command 1 12 0 1 F01 Select frequency command 2/1 Hz2/Hz1 Rotation direction processing Drive frequency command UP/DOWN keys on keypad [12] [C1] Frequency command 2 0 1 2 C30 FWD REV Fig.3-1. Block Diagram of the Pulse Train Input System Dwg. No. SI27-4391b 5/20

3.4. Function Code List Table3-3 lists function codes to be used for pulse rate input. Mounting the PG interface card can display o codes. Table3-3. Related Function Codes Code Name Data setting range Unit Default setting F01 (C30) o01 Frequency Command 1 (Frequency Command 2) Command/Feedback Input (Input mode) 0 to 3, 5. 7. 11, 12-0, 1, 2, 10, 11, 12 20, 21, 22 0 (2) Change When running N - 0 N o06 Command: (Filter time constant) 0.000 to 5.000 s 0.005 Y o07 (Pulse train input) (Pulse count factor 1) 1 to 9999-1 N o08 (Pulse count factor 2) 1 to 9999-1 N 3.5. Function Code Details F01 Frequency Command 1 (C30: Frequency Command 2) To drive the inverter with the pulse input frequency command, set the F01 (C30) data to "12" for frequency command 1 (frequency command 2). o01 Command/Feedback Input (Input mode) This function code switches the pulse input mode with the data in the ones place as listed in Table3-4. Table3-4. Data for o01 Pulse input mode Data for o01 Remarks B phase pulse input 0 Pulse input with polarity 1 A/B phase pulse input 2 Not available (This setting produces 0 p/s.) o06 Command (Pulse train input) (Filter time constant) This function code specifies a time constant determining a linear delay of the low pass filter for the reference speed given by pulse train. Adjusting this time constant can stabilize the speed command in low pulse rate. o07 o08 Command (Pulse train input) (Pulse count factor 1) Command (Pulse train input) (Pulse count factor 2) For the pulse input command, these function codes define the relationship between the input pulse rate and reference frequency. Reference frequency f * (Hz) o08 0 o07 Input pulse rate Np (kp/s) Fig.3-2. Relationship between the Input Pulse Rate and Reference Frequency Dwg. No. SI27-4391b 6/20

As shown in Fig.3-2, set the input pulse rate (kp/s) to the o07 data and set the reference frequency (Hz) at the pulse rate (specified by o07) to the o08 data. The relationship between the input pulse rate at A or B phases input and the reference frequency f* (or reference speed) can be calculated by the following expression. Pulse count factor 2 (o08) f* (Hz) = Np (kp/s) Pulse count factor 1 (o07) f* (Hz) : Reference frequency (In speed control, the frequency corresponding to the speed) Np (kp/s) : Input pulse rate at A or B phase input Dwg. No. SI27-4391b 7/20

4. Speed Control Using a PG feedback signal enables V/f control with PG and dynamic vector control with PG. It speed-controls the detection speed of the motor via the PG and compensates the frequency with PI control so that the motor speed follows the speed command. OPC-E1-PG3 can't be used as speed control and pulse rate input concurrently. 4.1. Specifications Table4-1 lists the specifications of speed control with PG. Table4-1. Specifications of Speed Control with PG Control Electrical specifications Item Specifications Remarks Speed control 180 to 3600 r/min When running at constant speed range (The maximum speed refers to Speed control the speed corresponding to ±0.2% of maximum speed accuracy the maximum frequency.) Open collector : 30m / 30kp/s Input pulse rate Complementary : 30m / 100kp/s or 100m / 30kp/s 4.2. Terminal Functions Table4-2 lists terminal functions. Table4-2. Terminal Functions Location PG interface card Inverter Terminal symbol Name Functions PI Power input terminal Receives power for the PG from an external source. PO Power output terminal Outputs power to the PG. CM Common terminal Common terminal for the PG power. YA Feedback input terminal Receives an A phase feedback pulse train. for A phase pulse train YB Feedback input terminal Receives a B phase feedback pulse train. for B phase pulse train YZ -- Reserved. Terminal [X] "Switch speed control" Temporarily cancels speed control with PG. (Note) terminal Note: "Switch speed control" terminal Setting "27" to any of function codes E01 to E05, E98 and E99 assigns the "Switch speed control" command PG/Hz to the corresponding one of digital input terminals [X1] to [X5], [FWD] and [REV]. This setting enables the assigned terminal to be used for canceling the speed control with PG. While the inverter is running, turning this terminal on or off will be ignored. After the inverter stops, it will be validated. If no PG/Hz is assigned, speed control with PG is always enabled. Table4-3. Function of PG/Hz Terminal Command Terminal command PG/Hz ON OFF Function Enable speed control with PG Disable speed control with PG Dwg. No. SI27-4391b 8/20

4.3. Function Code List Table4-4 lists function codes to be used for speed control with PG. Mounting the PG interface card can display o codes. Table4-4. Related Function Codes Code Name Data setting range Unit F42 (A14) Control Mode Selection 1 (Control Mode Selection 2) Default setting Change when running 0 to 4-0 N o01 0, 1, 2, Command/ Feedback Input (Input mode) 10,11,12, 20,21,22-0 N o02 Speed Control ( P Gain) 0.01 to 200.00 Times 10.00 Y o03 (I Integral time) 0.000 to 5.000 s 0.100 Y o04 (Filter time constant) 0.000 to 5.000 s 0.020 Y o09 o05 a Feedback Input (Encoder pulse resolution) 20 to 3600 P/R 1024 N o10 o06 a (Filter time constant) 0.000 to 5.000 s 0.005 Y o11 o07 a (Pulse count factor 1) 1 to 9999-1 N o12 o08 a (Pulse count factor 2) 1 to 9999-1 N o13 Speed Control (Output limiter) 0.00 to 100.00 % 100.00 Y 4.4. Function Code Details F42 Control Mode Selection 1 (A14: Control Mode Selection 2) To select the V/f control with PG interface or dynamic torque vector control with PG interface, set the F42 (A14) data to "3" or "4," respectively. o01 Command/Feedback Input (Input mode) This function code switches the feedback pulse input mode with the data in the ones place as listed below. Table4-5. Data for o01 Feedback pulse input mode B phase pulse input Forward/reverse pulse input A/B phase pulse input Data for o01 0 1 2 o02 o03 Speed Control (P Gain) Speed Control (I Integral time) These function codes specify the PI constants of a speed controller. The expression below shows the transfer function of the controller. f 1 = kp(1+ ) st S I ε K p : T I : f S : ε : s : P gain (o02) Integral time (o03) Slip frequency Speed deviation Laplace operator Suppose that the P gain is 1.0 when the speed deviation ε = 100% (Maximum Frequency F03 (A01)) and f S is 1% of the maximum frequency. Dwg. No. SI27-4391b 9/20

Suppose that the I integral time = 1.000 seconds when the o03 data is 1.000. Setting an excessive P gain may cause system hunting. A roughly recommended P gain should not exceed 35.00 in the ordinary system. Modifying F03 (A01) data requires readjustment of o02 and o03 data. o04 Speed Control (Filter time constant) This function code specifies a time constant determining a linear delay of the low pass filter for the speed command given by pulse train. Use this function code to suppress an overshoot that occurs, for example, when the speed command varies. o09 o05 a Feedback Input (Encoder pulse resolution) This function code specifies the resolution of the encoder mounted on the inverter-driven motor. o10 o06 a Feedback Input (Filter time constant) This function code specifies a time constant determining a linear delay of the low pass filter for the speed feedback given by pulse train. Use this function when large ripple components superpose the feedback pulse train. o11 o07 a o12 o08 a Feedback Input (Pulse count factor 1) Feedback Input (Pulse count factor 2) These function codes specify pulse count factors 1 and 2. Use these function codes when the motor shaft speed differs from the encoder (PG) shaft speed depending upon a transmission reduction ratio. Pulse count factor 2 (o08) Motor shaft speed = Pulse count factor 1 (o07) Encoder shaft speed a o13 Speed Control (Output limiter) This function code specifies the output limit percentage for the speed controller (PI controller). Specification of 100.00% is equivalent to the maximum speed (maximum frequency). To suppress the frequency control amount (PI controller output) to the extent of the motor's slip frequency in the speed control mode, use this function. Dwg. No. SI27-4391b 10/20

5. Positioning Control Using PG feedback signals enables positioning control. The inverter internally counts the feedback pulses and controls the motor so that the control object moves from the previously specified start point, decelerates and switches to the creep speed operation to arrive at the specified stop position. OPC-E1-PG3 can be used as speed control and positioning control concurrently. 5.1. Specifications Table5-1 lists the specifications of positioning control. Table5-1. Specifications of Positioning Control Item Specifications Speed control Range 180 to 3600 r/min Pulse input Maximum pulse rate Open collector : 30m / 30kp/s Complementary : 30m / 100kp/s or 100m / 30kp/s 5.2. Terminal Functions Table5-2 lists terminal functions for the positioning control alone (no concurrent use of the speed control with PG or frequency control with pulse rate input). Terminal symbol PI Table5-2. Terminal Functions (no concurrent use of speed control with PG or frequency control with pulse rate input) Name Functions Remarks Power input terminal Receives power for the PG from an external source. PO Power output terminal Outputs power to the PG. CM Common terminal Common terminal for the PG power. YA Input terminal for A Receives an A phase phase command/feedback pulse train. YB Input terminal for B Receives a B phase phase command/feedback pulse train. Specify the input mode with J86 or o01. YZ Input terminal for Z phase Receives a Z phase command/feedback pulse train. No connection needed if no preset positions are specified with J76 and J77. Dwg. No. SI27-4391b 11/20

5.3. Function Code List Table5-3 lists function codes to be used for positioning control. Mounting the PG interface card can display o codes. Table5-3. Function Codes Code Name Data setting range Unit E01 to E05, E98, E99 E20, E21, E27 Terminal [Xn] Function Terminal [Y1] Function Terminal [Y2] Function Terminal [30A/B/C] Function 42 (1042): Activate the limit switch at start point, LS 43 (1043): Start/reset, S/R 44 (1044): Switch to the serial pulse receiving mode, SPRM 45 (1045): Enter the return mode, RTN 80 (1080): Stop position override alarm, OT 81 (1081): Timer output, TO 82 (1082): Positioning completed, PSET 83 (1083): Current position count overflowed, POF 0.0: Disable Default setting Change when running - - N - - N Positioning Control J73 (Start timer) 0.1 to 1000.0: Preset time s 0.0 Y J74 (Start point, upper digits) -999 to 999 p 0 Y J75 (Start point, lower digits) [P], 0 to 9999 p 0 Y J76 (Preset point, upper digits) -999 to 999 p 0 Y J77 (Preset point, lower digits) [P], 0 to 9999 p 0 Y (Creep speed switch point, J78 upper digits) 0 to 999 p 0 Y (Creep speed switch point, J79 lower digits) 0 to 9999 p 0 Y J80 (Creep speed) 0 to 400 Hz 0 Y J81 (End point, upper digits) -999 to 999 p 0 Y J82 (End point, lower digits) 0 to 9999 p 0 Y J83 (Positioning allowance) 0 to 9999 p 0 Y J84 (End timer) 0.0: Disable. 0.1 to 1000.0: Preset time s 0.0 Y J85 (Coasting compensation) 0 to 9999 p 0 Y J86 (End point command) 0: B phase pulse input 1: Pulse input with polarity - 0 Y J87 (Preset positioning 0: Forward rotation direction 1: Reverse rotation direction requirement) 2: Both forward/reverse rotation direction - 0 N J88 (Position detection direction) 0: Forward direction 1: Invert the current direction ( -1). - 0 N 0, 1, 2, Command/Feedback Input o01 10,11,12, (Input mode) 20,21,22-0 N Dwg. No. SI27-4391b 12/20

5.4. Description of the Control The PG interface card allows the inverter to internally count feedback pulses issued from the encoder (PG) and control the motor so that the control object starts moving from the previously specified start point (S point), decelerates and switches to the creep speed operation to arrive at the specified stop position (E point). Turning a run command ON with "Start/reset" command S/R being ON starts the positioning control. See Fig.5-1 "Positioning Control Model" and Table5-4. Frequency Hz L (J78, J79) CP (J85) Reference frequency Creep speed (J80) 0 Time ST (J73) S point (J74, J75) Accl time (F07/E10) Z point (J76, J77) Decl time (F08/E11) Decl time (F08/E11) E point (J81, J82) ER (J83) Time ET (J84) t Start/reset S/R OFF ON Run command Timer output TO OFF OFF ON ON Positioning completed PSET OFF Note: The current position must be within E +/- ER point after the time ET has elapsed. ON Fig.5-1. Positioning Control Model Note: The positioning control applies to motor 1 only. During jogging (inching) operation or when the PID control is enabled (J01 0), the positioning control is disabled. An under voltage alarm that occurs in positioning control triggers an alarm ero; however, the inverter does not enter the restart mode (specified by F14). Enabling the positioning control disables the auto-reset function specified by H04 and H05. Dwg. No. SI27-4391b 13/20

5.5. Symbols Table5-4 lists the meanings of symbols used in Fig.5-1. Symbol Name S point Start point Function code J74, J75 Table5-4. Symbol Details Descriptions This specifies the start position data for the positioning control. It can be the current position [P] (absolute position) or numerical value (relative position). Specification of an absolute position and that of a relative position produce different results as described below. [Absolute position] Specifying [P] regards the current position as a start point. When starting the positioning control, the inverter applies the current position pulse count as start point data. (Example) Suppose that the current position pulse count = 10,000, the start point data = [P], and the stop point (E point) pulse count = 20,000. Then, when starting the positioning control, the inverter moves the control object from the current position (10,000, as start point data) to the E point (20,000). Accordingly, the object moving pulse count is 10,000 (20,000-10,000). [Relative position] Specifying "a" (numerical value) substitutes "a" for the current position data. When starting the positioning control, the inverter applies "a" pulses as start point data. (Example) Suppose that the current position pulse count = 10,000, start point data "a" = 4,000, and the stop position (E point) pulse count = 20,000. Then, when starting the positioning control, the inverter moves the control object from the start point pulse count "a" (4,000) instead of the current position data (10,000) to the E point (20,000). Accordingly, the object moving pulse count is 16,000 (20,000-4,000). ST Start timer J73 This specifies the waiting time from when a run command comes ON with the S/R terminal command being ON until the inverter starts running the motor. (This covers the delay of brake OFF.) If the output frequency has not been zero (inverter running), turning the Z point Preset position L CP Creep speed switch point Coasting correction E point End point ER Positioning allowance terminal command S/R ON does not start the timer count. (During deceleration triggered by turning the run command OFF, the start timer does not start as well.) J76, J77 When the inverter detects that the Z signal is turned from Low to High first after the LS terminal command is turned from OFF to ON, it corrects the current position data for the preset position data (Z point). This is functionally equivalent to a mechanical position correction or origin point reset. Specifying [P] to the preset position does not perform the Z point correction. It is also possible to restrict the application of the Z point correction with the LS to the motor rotational direction specified by function code J87. J78, J79 J85 This specifies an absolute position pulse count required from a deceleration start point (towards the creep speed specified by J80) to the E point. This specifies the deceleration start point that follows the end of creep-speed operation. Specify it with the pulse count from the E point. Take into account the inertia produced when the control object decelerates to stop. J81, J82 This specifies a target stop position. J83 This specifies the positioning allowance at the E point, that is, "Actual stop position - E point position." After the end timer counts up: If "Actual stop point - E point " ER, the inverter issues the "Positioning completed" signal PSET. If "Actual stop point - E point " > ER, the inverter issues the "Stop point alarm" signal OT. Dwg. No. SI27-4391b 14/20

Table5-5. Symbol Details (Continued) Symbol Name Function code Descriptions ET End timer J84 This specifies the waiting time from when the control object stops at E point until the inverter can receive the next positioning control signal. After completion of positioning, when this waiting time has elapsed or when 0.5 second has elapsed if ET < 0.5 second, the inverter issues the "Positioning completed" signal PSET or "Stop point alarm" signal OT. Turning the run command OFF when the ET is counting interrupts the counting, so the inverter does not issue PSET or OT. The inverter ensures that PSET and OT signals are kept ON for at least 100 ms. 5.6. Input/output terminal functions Table5-6. Input Terminal Functions Terminal function Activate the limit switch at start point Start/reset Switch to the serial pulse receiving mode Enter the return mode Terminal command LS S/R SPRM RTN Description This is used when the inverter corrects the current position data for the preset position data (Z point) specified by function codes J76 and J77. When the inverter detects that the Z signal is turned from Low to High first after the LS terminal command is turned from OFF to ON, it triggers the Z point correction. In any other conditions, the LS terminal command produces nothing. This enables or disables the positioning control. ON: Enable OFF: Disable This enables or disables the serial pulse receiving mode. When the serial pulse input shares an input terminal with other functional pulse inputs (when the positioning control is concurrently enabled with frequency control with pulse rate input and/or speed control with PG) with function code setting, the inverter counts input pulses only from the PG for the stop position when the SPRM terminal command is ON. ON: Enable OFF: Disable If the serial pulse receiving is exclusively assigned to the digital input terminal for the PG input, however, the inverter counts the input pulses for the stop position, regardless of the SPRM status. Turning the SPRM ON zero-clears the pulse count (E point data previously specified by J81 and J82). Starting the positioning control with the RTN terminal command being ON enables the return mode in which the inverter moves the control object in the reverse direction while keeping the S and E point data. Using the RTN enables the reciprocal positioning control; moving from S to E points and returning from E to S points. ON: Enable OFF: Disable Dwg. No. SI27-4391b 15/20

Table5-7. Output Terminal Functions Terminal function Stop position override alarm Timer output Positioning completed Current position count overflowed Symbol Description OT TO PSET POF ON conditions The ET time has elapsed (or after 0.5 second if ET < 0.5 s) or "Actual stop position E-point" > ER data. OFF conditions Except the above ON conditions. ON conditions Until the ET time has elapsed after the start timer (J73) starts. OFF conditions Except the above ON conditions. When the ET is cancelled, the output frequency becomes 0 Hz, turning this signal OFF.. ON conditions The ET time has elapsed (or after 0.5 second if ET < 0.5 s) or "Actual stop position E-point" > ER data. OFF conditions Except the above ON conditions. ON conditions The current position pulse count goes out of the range from -9,999,999 to +9,999,999, regardless of the ON/OFF state of the SR terminal command. OFF conditions The position count comes within the specified range after going out of the range, Any run command is turned ON with the S/R being ON, or A Z point correction is performed. 5.7. Serial Pulse Receiving Function When the S/R terminal command is assigned to any digital input terminals [X]s and the serial pulse receiving function is enabled, the pulse train input from host equipment can specify the stop position (E point). Function codes J81 and J82 (Stop position) save the input pulse count. Function code J86 specifies the pulse input mode for the serial pulse train input. Dwg. No. SI27-4391b 16/20

6. Protective Functions If any inverter protective function is activated to issue an alarm, the inverter displays the corresponding alarm code on the LED monitor of the keypad and shuts down its output. Accordingly, the motor coasts to a stop. Table6-1 lists alarm codes related to the PG interface card Table6-1. Related Alarm Codes Alarm for: Alarm Frequency control Refer to Alarm name Speed Positioning code with pulse Section: control control rate input OS Overspeed alarm NA Y NA 6.1 ErE Excessive speed deviation alarm NA C NA 6.2 Ero Positioning control alarm NA NA Y and C 6.3 Y: Always active. The protective function for the alarm is always active when the control is enabled. C: Conditionally active. The protective function for the alarm is active when the control is enabled and the protective function is enabled with the function code. The factory default is "enabled." NA: Not available when the control is enabled. 6.1. Overspeed Alarm (OS) Table6-2. Overspeed Alarm Specifications Alarm code OS Descriptions The inverter issues this alarm when the detected speed exceeds the 1.2 times the minimum value of either (1) or (2) below. (1) For the selected motor, Maximum frequency (F03 or A01) + Torque limiter (Frequency increment limit for braking, H76) (2) Frequency limiter, High (F15) This protective function works when the inverter is outputting with the speed control with PG being enabled (F42 or A14 = 3 or 4 and PG/Hz is ON). 6.2. Excessive Speed Deviation Alarm (ErE) Table6-3. Excessive Speed Deviation Alarm Specifications Alarm code ErE Descriptions This protective function recognizes a PG error by software based on the relationship between the speed command and the detected speed. When the speed deviation between the speed command and the detected speed has exceeded the excessive speed deviation level specified by o17 during the period longer than the timer setting specified by o18, the protective function issues this alarm. This protective function provides two choices--"stop running" (o19 = 1 or 2) and "Continue to run" (o19 = 0) when it is activated. When the latter is selected, the inverter continues to run with output to terminal [Y] without issuing an alarm. This protective function works when the inverter is outputting with the speed control with PG being enabled (F42 or A14 = 3 or 4 and PG/Hz is ON). It does not, however, during DC braking or idling due to overload. Dwg. No. SI27-4391b 17/20

6.2.1. Function codes Table6-4 lists function codes related to excessive speed deviation alarms. Table6-4. Related Function Codes Code Name Data setting range Unit Default setting Change when running o17 Excessive Speed Deviation Level 0 to 50 % 10 Y o18 Excessive Speed Deviation Timer 0.0 to 10.0 s 0.5 Y 0: Continue to run o19 PG Error Processing 1: Stop running (Alarm mode 1) 2: Stop running (Alarm mode 2) - 2 N E20 Terminal [Y1] Function 0 76(1076): E21 Terminal [Y2] Function - 7 PG error signal PG-ERR E27 Terminal [30A/B/C] Function 99 6.2.2. Excessive speed deviation detection Table6-5 lists the relationship between PG error detection conditions and error processing (o19). Table6-5. Data for o19 Data and Error Detection PG-ERR Data for o19 Conditions determining the excessive speed deviation Alarm output 0: Continue to run None Active Any status of 1to 6in Fig.6-1 is kept exceeding the 1: Stop running timer setting specified by o18. (Alarm mode 1) 2: Stop running (Alarm mode 2) Any status of 1to 8in Fig.6-1 is kept exceeding the timer setting specified by o18. ErE Inactive N Detected speed 1, 2: A/B phases of the PG inversely wired 1 3 7 5 Hysteresis width (o17 x Maximum frequency) 3, 4: Excessive speed deviation Detected speed > Speed command 5, 6: PG wire broken or the load locked 6 8 Speed command -0.1 Hz to +0.1 Hz 4 2 7, 8: Excessive speed deviation Detected speed < Speed command Fig.6-1. Excessive Speed Deviation Detection and Speed Command Dwg. No. SI27-4391b 18/20

6.3. Positioning Control Alarm (Ero) Table6-6. Positioning Control Alarm Specifications Alarm code Ero Descriptions When the protective function detects an under voltage during operation in positioning control, it issues this alarm. This alarm is contained in alarm category "Y" in Table 8.1, so it cannot be disabled by any function code. This protective function recognizes a PG error by software based on the position pulse feedback status against its output frequency. This alarm occurs if: (1) The position pulse input count does not change when the inverter output frequency has exceeded the hysteresis width (specified by E30 Frequency Arrival, for 2.5 Hz min.) during the period longer than the timer setting specified by o18. (2) The polarity is being incongruent between the inverter output frequency and feedback position pulse when the inverter output frequency has exceeded the hysteresis width (specified by E30 Frequency Arrival, for 2.5 Hz min.) during the period longer than the timer setting specified by o18. If the o18 data (Excessive speed deviation timer is set to 0.0 s (Disable detection), however, any alarm will not occur in both cases (1) and (2). This alarm is contained in alarm category "C" in Table 8.1. 6.3.1. Function codes Table6-7 lists function codes related to positioning control alarms. Table6-7. Related Function Codes Code Name Data setting range Unit Default setting Change when running o18 Excessive Speed Deviation Timer 0.0 to 10.0 s 0.5 Y E30 Frequency Arrival (Hysteresis width) 0.0 to 10.0 Hz 2.5 Y J88 Positioning Control (Position detection direction) 0: Forward direction 1: Reverse direction (Inverts the current direction (x -1)) - 0 N Dwg. No. SI27-4391b 19/20