Technical Note. Technical Note - DLC. Dynamic Load Compensation

Similar documents
Compact Signal Calibrator

DTI-1000 & STS-100/102. Digital Temperature Indicator & STS Reference Sensor

STS series Superiour Temperature reference Sensors

RTC-158 & RTC-250. Reference Temperature Calibrator. Both for liquid bath and dry-block use NEW!

Compact Signal Calibrator

JOFRA STS series Superiour Temperature reference Sensors

Compact Signal Calibrator

Model ETC-series Easy Temperature Calibrator

ETC Series. Easy Temperature Calibrator. This may be the fastest dry-block calibrator in the world

9190A Ultra-Cool Field Metrology Well. Ultra-cool dry-block calibrator with best-in-class stability

9190A Ultra-Cool Field Metrology Well

Millikelvin Thermometers MKT 10 MKT 50

Integrated calibration system for electronic and pneumatic instrumentation model CBS-SC2000

Ultra-cool dry-block calibrator with best-in-class stability Technical Data. Improved process control

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

AVX Wire-to-Wire Connectors

MAGNATEST D. Magneto-Inductive Component Testing for Magnetic and Electrical Properties

Temperature Sensing and Measurement Solutions THERMOMETRY PRODUCT GUIDE

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

An Explanation of GP:50 Performance Specifications

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

AVX Wire-to-Wire Connectors

CrystalControl User s Manual. for nvision Reference Recorder and HPC40 Series Pressure calibrator

TESTING EQUIPMENT SHEAR STRENGTH PARAMETERS SOIL. established in 1972

Altitude and Airspeed Measurements Temperature Range. Range psid psig psia 0 to 1 0 to 5 0 to 15 0 to 30 0 to 50 0 to to to 300

UT-ONE Accuracy with External Standards

Additel 875 Series Dry Well Calibrators

On-site multifunction calibrator

NEW EASYLOCK ZERO POINT CLAMPING SYSTEM. Palletising and clamping tools from a single source

CALYS 150. Advanced documenting multifunction calibrator thermometer

Additel 875 Series Dry Well Calibrators

RSF25. RETHINKING MANU FAC- TURING. WHATEVER YOUR VISION FOR TOMORROW MIGHT BE: BUILD IT TODAY.

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Extending test capabilities of the PXI 3000 RF test solution with 3060 Series RF combiner modules

Development. Founded in: Employees: 500+

CALYS 150. Advanced documenting multifunction calibrator thermometer

CALYS 150. Advanced documenting multifunction calibrator thermometer

LTE Radio Channel Emulation for LTE User. Equipment Testing

Catalog No. E Perfectly formed for production, quality control rooms and laboratories form measuring instruments from Mitutoyo

Keysight Technologies 1 mw 50 MHz Power Reference Measurement with the N432A Thermistor Power Meter. Application Note

Industrial Instrumentation

L100 The ultimate CMM laser scanner combining productivity and accuracy NIKON METROLOGY I VISION BEYOND PRECISION

LK V xx Technical Datasheet

Tooling state of the art and unique

LWT-2080/3080. CNC Worm Thread Grinding Machine.

Technical assistance for the Animal Health Department of the KVFA and the Food and Veterinary Laboratory (Kosovo) - Deliverable 9.

- Clamshell - OD-Mounted Pipe Cutting and Beveling Machine. Split frame. cutting and beveling simultaneously

Pressure transmitter for general industrial applications Model A-10

LUG CNC Universal Gear & Tool Grinding Machine.

Pressure transmitter for general industrial applications Model A-10

Agilent 5527A/B-2 Achieving Maximum Accuracy and Repeatability

NGR. Guided Wave Radar Level Transmitter

ED701 General Industry Pressure Transmitter

Brighten your Expertise

Pressure transmitter For general industrial applications Model A-10

Form Talysurf i-series. A high resolution instrument range offering automated surface and contour inspection

4-20mA, 0-10V and general process measuring bargraph displays

Discover. Blue Box. the. Difference. High Resistance Metrology Products Guide

PRODUCT MANUAL. Flush Mount 1 mm Cavity TS FM01 K. Training and Technology for Injection Molding. Temperature Sensor

Easy-To-Use Graphic Interface

X-Shape Precise flatness measurement and control

Double Spindle Double Turret Multi-Tasking Turning Center DT42 DT52. Turning Precision Into Perfection

Movoline. In-Process Metrology

ME 410 Mechanical Engineering Systems Laboratory

Process Automation. Sensors and Systems: Level Sensors Level Switches Overfill Prevention Pressure Sensors Temperature Sensors

ph or ORP Transmitter

TYPE SE and TSE, SILICON CARBIDE SPIRAL HEATING ELEMENTS

VERSAPRINT 2 The next generation

Thermocouple Conditioner and Setpoint Controller AD596*/AD597*

CrankGrind. Keydata. The new generation of crankshaft grinding. A member of the United Grinding Group

HC Hydraulic Expansion Chucks

H1B Motor Electric Proportional Control L1, L2

Temposonics Magnetostrictive, Absolute, Non-contact Linear-Position Sensors

AUTOMATION ACCESSORIES

SPLIT FRAME CUTTING & BEVELING MACHINES

Ultra-high speed inkjet droplet measurement and monitoring with laser diagnostics

CALYS channels High accuracy calibrator

Extrusion lines for catheter tubing

Understanding the Precision Antenna, Cable, and Power Measurements on the 3550 Radio Test System

LITHIUM ION BATTERY WEB GAUGING APPLICATIONS

Repeatability. ± 0.2 µm ( '') Centrally focused / 639 nm / <1 mw. Temperature range 10 C - 50 C

OPTITEMP. Compact sensors

A Simple Pressure Sensor Signal Conditioning Circuit

ABOVE AND BEYOND HONING. Small Engine PRECISION BORE MACHINING SYSTEMS & SOLUTIONS

Calibration Traceable to NIST

CSM High-Voltage Measurement Systems

CALYS 100. Field precision documenting multifunction calibrator

Hygro-ThermoTransmitter-compact xxx

ENGLISH S-CO2 AMBIENT AIR SENSOR INSTALLATION AND OPERATING INSTRUCTIONS CO 2. TF5701_B_v1_web

OPTISENS PH 8390 Technical Datasheet

Machine Tools That Create Solutions Since 1939

DROP SHAPE ANALYZER DSA100 THE VERSATILE HIGH-END INSTRUMENT FOR ANALYZING COATING AND WETTING PROCESSES

The machine tool business of SKF. The profile

Datasheet. messtechnik gmbh. Torque ranges from 0,5 to 1000 Nm. Features. Extra Features DRBK-A. Torque Transducer DRBK + DRBK-A

EBI 10 High Precision Wireless Data Loggers

PCI Express Receiver Design Validation Test with the Agilent 81134A Pulse Pattern Generator/ 81250A ParBERT. Product Note

CALYS 75. Field documenting multifunction calibrator

TD9000 Tangent Delta Tester

Key data. Precision for small workpieces. A member of the United Grinding Group

Transcription:

Technical Note Dynamic Load Compensation Technical Note - DLC Calibrate multiple, odd sized or large sensors without compromising the accuracy Improved and documented uncertainty budget calculations Accuracy improved by a factor of 3 compared to normal dry-block calibration

JOFRA is continuously seeking new ways of improving temperature calibration. The DLC calibration correction technology is yet another state of the art innovation within temperature calibration. DLC is short for Dynamic Load Compensation: the principle is innovative and patent pending. What is the Dynamic Load Compensation system? The Dynamic Load Compensation system combines a measuring/control system with a newly developed Dynamic Load sensor. DLC Sensor What is the purpose of the Dynamic Load Compensation? The DLC system has been developed to deal with a major contributor to calibration errors. A dry-block used as a calibration instrument has some inherent error mechanisms. It is a fact that the sensor under test will affect the calibration accuracy during calibration. The sensor transmits energy to and from the calibrator. This heat exchange between the calibrator and the environment has a considerable negative impact on the calibration accuracy. The extent of the error depends on many factors: sensor size (diameter and length), number of sensors in the well and the difference between calibration temperature and ambient temperature. In other words, calibration accuracy is actually influenced by the actual load of the calibrator. Patent pending! 2 www.jofra.com DLC Dynamic Load Compensation

How does the DLC system work? JOFRA temperature calibrators are already famous for their active dual-zone calibration principle. With the DLC system, we have taken this well-proven and acknowledged dual-zone principle one step further. The load compensation is now active both within the heating block and inside the insert during calibration. The DLC sensor measures the actual temperature difference between two defined points inside the insert. See the purple dots. The DLC sensor is designed to process input to the heat control system of the calibrator to ensure that the axial gradient deviations in the lower 60 mm of the insert are kept to a minimum. The temperature difference between the bottom and the zone at 60 mm from the bottom is controlled within a few hundreds of a degree. The DLC system reacts immediately to changes in the load of the insert and controls the heat distribution to achieve the minimum axial gradient. The display value of the DLC shows 0.00 (or very close to this value) when the above mentioned minimum axial gradient has been achieved. ATC Dual-zone active block. Adaptive load compensation in block. RTC Dynamic Load Compensation. Adaptive load compensation in insert. Bottom Bottom Dynamic Load Compensation DLC www.jofra.com 3

How much does the DLC system improve your calibration results? The DLC system improves the calibration accuracy significantly. This may be illustrated and proven by two different test scenarios. The first scenario shows the improvements when measuring in the insert. The graph below illustrates the temperature change in the insert as a function of the distance from the bottom. Ideally this should be a straight line with no temperature variation vertically in the insert. If so, the axial gradient would be zero. However, this is not the case in practice. To prove that the DLC functionality will improve the axial gradient, three tests have been performed. The first test is to put a very light load on the RTC calibrator, which should produce a very little axial gradient (blue line). The load is a 4 mm external reference sensor, a 3 mm sensor and the DLC sensor. The maximum deviation from the ideal straight line is 0.015 C. The next test is to load the RTC calibrator more heavily (red line). A thicker, 10 mm, sensor is added to the configuration detailed in the previous test. The DLC functionallity is not activated. The heavier loading of the calibrator causes a nonlinear axial gradient. The maximum deviation from the ideal straight line is 0.160 C. The last test is carried out with exactly the same load as above, but we will now activate the DLC functionallity to see how efficiently the DLC will straighten the gradient (green line). The maximum deviation from the ideal straight line is 0.025 C. RTC-156, S/N 574360-00037: Axial homogeneity @ 155 C. C 0,10 0,05 0,00-0,05 0 10 20 30 40 50 60 70 80 mm -0,10-0,15-0,20-0,25-0,30 Load: DLC+Ext. Ref.+3mm SUT. DLC on Load: DLC+Ext. Ref.+3mm SUT + 10mm SUT. DLC off Load: DLC+Ext. Ref.+3mm SUT + 10mm SUT. DLC on The effect of using the patent pending DLC system can be expressed in two ways: 1) A heavily loaded RTC calibrator can perform a close to ideal straight line gradient by activating the DLC functionallity. 2) The maximum deviation from the ideal straight line is, in this example, improved by a factor 6 by activating the DLC. Improvement factor = ratio 0.160 : 0.025 > 6 4 www.jofra.com DLC Dynamic Load Compensation

The second scenario shows the improvement when comparing with an ideal bath calibration. The principle of this test is to calibrate a sensor in a calibration bath (ideal calibration represented in line 1) and compare the result with the results of the same sensor in an RTC calibrator with and without the DLC function (see table below). In addition to the original sensor, a 10 mm sensor is added to the RTC (lines 2 & 3). This extra load on the calibrator has a large impact on the calibration result of the 3 mm sensor (line 2). The DLC functionallity is not activated. With the exact same load on the RTC calibrator, we now activate the DLC functionallity and the accuracy is consequently improved. This test shows the following effect when using the DLC: 1: Uncertainty due to thermal load is reduced by a factor 3 when using the DLC (ratio 0.024 : 0.008 = 3) 2: DLC provides optimum accuracy under any thermal loads Test setup SET ( C) TRUE ( C) SUT1 ( C) SUT1 Deviation ( C) Deviation from bath calibration ( C) 1 Bath Calibration 155,000 154,973 154,923-0,050 -- 2 RTC-156, DLC=off, SUT1 + SUT2 155,000 155,000 154,974-0,026 0,024 3 RTC-156, DLC=on, SUT1 + SUT2 155,000 155,000 154,958-0,042 0,008 Example: Calibration of a OD 3mm (SUT1) and OD 10mm (SUT2) at the same time. What are the advantages of the patent pending DLC system? Calibration of several sensors simultaneously Calibration of large diameter sensors Since no standard temperature sensors have a thermo sensitive lenght beyond 60 mm, it is no longer necessary to know the length of the thermo-sensitive part of the sensor. Just plug it in! The DLC indicator shows that the dual-zone is active and working A perfectly working calibrator. The DLC value is very close to 0.00 when the calibrator is loaded or not loaded Calibration value indication. The DLC indicator shows when the temperature homogeneity in the lower 60 mm part is achieved What are the important benefits for the user? Saves time by calibrating more sensors simultaneously Calibrating big diameter sensors without loosing accuracy due to heat conduction TSL (Thermo Sensitive Length) independency. Safe, secure and accurate calibration results without spending time to get sensor specifications from your supplier The DLC function minimizes the influence from sensor production tolerances like the Pt100 element being mounted in various positions in the sensor All temperature sensors that can be placed in the bottom of the calibrator will be calibrated without error The displayed DLC value indicates when the optimum temperature homogeneity is achieved The displayed DLC value shows when the load has no influence on the calibration result When the DLC value is close to zero, the calibration technician knows that the calibration results are reliable The DLC indicator proves that the dual-zone is active and well-functioning The DLC in conjunction with the stability indicaton show when the calibration value is ready. The green-zero rule (see page 7) Dynamic Load Compensation DLC www.jofra.com 5

Why does the DLC have a possitive impact on the uncertainty budget? Our customers often want to make uncertainty budgets for their calibrations. This is usually done by entering the values from the supplier s datasheet. These values are normally rather conservative to ensure that specifications are valid for all calibrators. The uncertainty budget results are consequently very high. Through the DLC measurement, some of the specifications can be changed with the actual values of the instrument thus providing a far better measuring capability of the calibrator. The advantage of the DLC system is illustrated by comparing of two uncertainty budgets. Uncertainty budget RTC calibrator loaded with Ø 10 mm sensor DLC off 10 mm load 1 Temperature of reference thermometer 155.002 2 Uncertainty reference thermometer (k=2) 0.015 Normal 0.0075 3 Resolution of RTC temperature indicator 0.001 Square 0.0003 4 Hysteresis effect 0.008 Square 0.0046 5 Axial temperature homogeneity 0.159 Square 0.0918 6 Radial temperature homogeneity 0.004 Square 0.0023 7 Loading effect 0.004 Square 0.0023 8 Stability in time 0.003 Square 0.0017 155.002 k=1 0.092 Geometrical sum* k=2 0.185 Uncertainty budget RTC calibrator loaded with Ø 10 mm sensor DLC on 10 mm load 1 Temperature of reference thermometer 155.002 2 Uncertainty reference thermometer (k=2) 0.015 Normal 0.0075 3 Resolution of RTC temperature indicator 0.001 Square 0.0003 4 Hysteresis effect 0.008 Square 0.0046 5 Axial temperature homogeneity 0.024 Square 0.0139 6 Radial temperature homogeneity 0.004 Square 0.0023 7 Loading effect 0.004 Square 0.0023 8 Stability in time 0.003 Square 0.0017 155.002 k=1 0.017 Geometrical sum* k=2 0.034 * Geometrical sum: Square root of the sum of the squares 1. The uncertainty of the axial gradient has been reduced by 85% when using the DLC system. 2. The RTC calibrator is performing within specifications even while heavily loaded. 3. The total uncertainty is improved by a factor 5 when using the DLC function. Improvement factor = ratio 0.185 : 0.034 > 5 6 www.jofra.com DLC Dynamic Load Compensation

How can the calibration technician easily see when the calibrator is ready? The RTC calibrator shows and proves when the optimum gradient and stabilization has been achieved (Green-Zero illustration). No other calibrators worldwide, are able to provide this essential status information. What are the most frequent questions in connection with the DLC? Does the DLC sensor have any negative impact on the calibration accuracy? Since the diameter of the DLC sensor is only 3 mm, it does not impact the measurements. What is the significance of the sign in the DLC display value? A positive display value of the DLC means that the top of the 60 mm measuring zone is hotter than the bottom and vice versa. What are the major conclusions related to the DLC system? 1 The RTC calibrator with the DLC system is the only dry-block in the world that fully compensates for the actual load. The green-zero rule as shown on a type B of the RTC calibrator series. 2 Compared with an ideal bath calibration, the achieved accuracy with the DLC is improved by a factor 3. 3 With reference to a load test with a 10 mm load sensor, the axial gradient over a 60 mm length is improved by a factor 6 by activating the DLC system. 4 All temperature sensors can be calibrated without first spending costly time on investigating sensor details, such as Thermo Sensitive Lengths, production tolerances, etc. 5 The DLC display supports your effort to make a more qualified and realistic uncertainty budget. 6 Typically you just have to trust datasheet specifications. With the DLC system, you have the first temperature calibrator where the display shows and proves its own datasheet specifications. Dynamic Load Compensation DLC www.jofra.com 7

Calibrators with DLC RTC-156 Temperature range from -30 to 155 C (-22 to 311 F) General purpose light-weight and high performance dry-block. RTC-157 Temperature range from -45 to 155 C (-49 to 311 F) General purpose light-weight and high performance dry-block with superior low temperature performance. RTC-158 Temperature range from -22 to 155 C (-8 to 311 F) Combined liquid bath and dry-block with a large diameter insert, designed for calibration of odd sizes or shapes of sensors or when calibrating multiple sensors at a time. RTC-159 Temperature range from -100 to 155 C (-148 to 311 F) The most versatile temperature calibrator available with a temperature range that makes it especially ideal for use in the health care, medical, pharmaceutical, biotechnology and food industries. RTC-250 Temperature range from 28 to 250 C (82 to 482 F) Combined liquid bath and dry-block with a large diameter insert, designed for calibration of odd sizes or shapes of sensors or when calibrating multiple sensors at a time. RTC-700 Temperature range from 33 to 700ºC (91 to 1292ºF) A unique combination of speed and accuracy at very high temperatures based on our new patent pending heating block. AMETEK Calibration Instruments is one of the world s leading manufacturers and developers of calibration instruments for temperature, pressure and process signals as well as for temperature sensors both from a commercial and a technological point of view. JOFRA Temperature Instruments Portable precision thermometers. Dry-block and liquid bath calibrators: 5 series, with more than 25 models and temperature ranges from -90 to 1205 C / -130 to 2200 F. All featuring speed, portability, accuracy and advanced documenting functions with JOFRACAL calibration software. JOFRA Pressure Instruments Convenient electronic systems ranging from -25 mbar to 1000 bar (0.4 to 15,000 psi) - multiple choices of pressure ranges, pumps and accuracies, fully temperature-compensated for problem-free and accurate field use. JOFRA Signal Instruments Process signal measurement and simulation for easy control loop calibration and measurement tasks - from handheld field instruments to laboratory reference level bench top instruments. JOFRA / JF Marine Instruments A complete range of calibration equipment for temperature, pressure and signal, approved for marine use. FP Temperature Sensors A complete range of temperature sensors for industrial and marine use. M&G Pressure Testers Pneumatic floating-ball or hydraulic piston dead weight testers with accuracies to 0.015% of reading. M&G Pumps Pressure generators from small pneumatic bicycle style pumps to hydraulic pumps generating up to 1,000 bar (15,000 psi). www.jofra.com UK AMETEK Calibration Instruments Tel +44 (0)1243 833 302 jofra@ametek.co.uk Denmark AMETEK Denmark Tel +45 4816 8000 jofra@ametek.com Singapore AMETEK Singapore Pte Ltd Tel +65 6484 2388 jofra@ametek.com France AMETEK S.A.S. Tel +33 (0)1 30 68 89 40 general.lloyd-instruments@ametek.fr Germany AMETEK GmbH Tel +49 (0)2159 9136 510 info.mct-de@ametek.de USA AMETEK Mansfield & Green Tel +1 (800) 527 9999 cal.info@ametek.com India AMETEK Instruments India Pvt Ltd. Tel +91 22 2836 4750 jofra@ametek.com Information in this document is subject to change without notice. 2011, by AMETEK, Inc., www.ametek.com. All rights reserved. China AMETEK Inc. - Shanghai Tel +86 21 5868 5111 AMETEK Inc. - Beijing Tel +86 10 8526 2111 AMETEK Inc. - Guangzhou Tel +86 20 8363 4768 jofra.sales@ametek.com.cn Pub code TN-DLC Issue 1101