Product Catalogue Millimeter Wave, Sub-Millimeter Wave / THz Solutions

Similar documents
Millimeter Wave Product Catalogue VivaTech Consulting S.A.R.L.

SERIES MXP BALANCED MIXERS FEATURES: APPLICATIONS: DESCRIPTION

MICROWAVE MICROWAVE TRAINING BENCH COMPONENT SPECIFICATIONS:

SERIES DET GENERAL PURPOSE DETECTORS DESCRIPTION. Millimeter-Wave Technology & Solutions

FREQUENCY MULTIPLIERS

Millimeter Wave Components & Subsystems. Airport East Business Park, Farmers Cross, Cork, Ireland

AMPLIFIERS, ANTENNAS, MULTIPLIERS, SOURCES, WAVEGUIDE PRODUCTS MILLIMETER-WAVE COMPONENTS FERRITE PRODUCTS AND SUB-SYSTEMS

Double-Ridged Waveguide Horn

Ultra High Frequency Measurements

Table of Contents. About SAGE Millimeter, Inc...1 Radar basics and related SAGE Millimeter microwave sensor technologies... 2

Banded Milimeter Wave Network Analysis TECHNICAL OVERVIEW

RS3400W/04 77 GHz Radar Sensor

Harmonic Mixers And their application with Spectrum Analysers Application Note Revision: February 2009

MILLIMETER WAVE SOURCE MODULE BROCHURE

Microwave. Accessories for Microwave Scalar and System Analyzers

87415A microwave system amplifier A microwave. system amplifier A microwave system amplifier A microwave.

Multi-Function Assemblies

Parameter Min. Typ. Max. Units

SC5407A/SC5408A 100 khz to 6 GHz RF Upconverter. Datasheet. Rev SignalCore, Inc.

Matched EW/ECM Subsystems 2-18 GHz

PRODUCT CATALOG MICROWAVE & MILLIMETER WAVE COMPONENTS & SUB-ASSEMBLIES 5 TO 325 GHZ

K-LC2 RADAR TRANSCEIVER

Signal Generator Extension Modules Operational Manual

Heterodyne Sweeping Radiometer

Advanced Test Equipment Rentals ATEC (2832)

CUSTOM INTEGRATED ASSEMBLIES

Keysight 2-Port and 4-Port PNA-X Network Analyzer

SAGE Millimeter, Inc.

DSA700 Series Spectrum Analyzer

Microwave Antennas making the world smaller

Keysight Technologies N9320B RF Spectrum Analyzer

ASTRO 25 The STR 3000 is compatible with Project MHz and 800 MHz trunking systems.

60 GHz RX. Waveguide Receiver Module. Features. Applications. Data Sheet V60RXWG3. VubIQ, Inc

Agilent ESA-L Series Spectrum Analyzers

CobaltFx Series EXTEND YOUR REACH. Frequency Extender System from. Frequency bands from: GHz, GHz, GHz

Agilent N9320B RF Spectrum Analyzer

Development of high cost performance signal analyzer MS2830A -044/045

60 GHz Receiver (Rx) Waveguide Module

Keysight Technologies PNA Microwave Network Analyzers

Engineering the high quality cost effective solutions. Short form selection catalogue

Agilent 83554A/83555A/83556A mm-wave Source Modules* Data Sheet

5G and mmwave Testing

CONTENTS MEASUREMENT INSTRUMENTS AND W/G COMPONENTS FOR SUBMILLIMETER WAVES

SAGE Millimeter, Inc.

Features OBSOLETE. = +25 C, IF= 1 GHz, USB, LO = +15 dbm [1]

Banded Millimeter Wave Network Analysis TECHNICAL OVERVIEW

AV3672 Series Vector Network Analyzer

RF Components Product Catalogue

Integrated Microwave Assemblies

Multifunctional Microwave Analyzer

SERIES PLS PHASE LOCKED SYNTHESIZER. FEATURES: Small Size, Low Cost, Simple to use Low Phase Noise Auto-sensing Internal or External 10MHz Reference

FREQUENCY MULTIPLIERS

Understanding RF and Microwave Analysis Basics

Ka Band Radar Transceiver

Features. Upconversion & Downconversion Applications MIXERS - SINGLE & DOUBLE BALANCED - SMT

SUNSTAR 微波光电 TEL: About Technologies was founded in the beginning of 2. is committed to providing our customers with

Agilent 8360B/8360L Series Synthesized Swept Signal/CW Generators 10 MHz to 110 GHz

Keysight Technologies Gustaaf Sutorius

Manufacturers of RF and Microwave Components and Assemblies Specialist in RF Filters, Power amplifiers and RF Switches

Cavity Filters. Waveguide Filters

USER OPERATION AND MAINTENANCE MANUAL

Elisra MMIC Catalog MMIC Catalog

Agilent 2-Port and 4-Port PNA-X Network Analyzer. N5241A - 10 MHz to 13.5 GHz N5242A - 10 MHz to 26.5 GHz Data Sheet and Technical Specifications

Features. = +25 C, IF = 200 MHz, LO = 0 dbm, Vcc = Vcc1, 2, 3 = +5V, G_Bias = +2.5V*

Keysight Spectrum Analyzer Option (090/S93090xA) for PNA/PNA-L/PNA-X/N5290A/N5291A

772D coaxial dual-directional coupler 773D coaxial directional coupler. 775D coaxial dual-directional coupler 776D coaxial dual-directional coupler

THz Vector Network Analyzer Development & Measurements

60 GHz TX. Waveguide Transmitter Module. Data Sheet Features V60TXWG3. Applications. VubIQ, Inc

Keysight Technologies Making Accurate Intermodulation Distortion Measurements with the PNA-X Network Analyzer, 10 MHz to 26.5 GHz

INC. MICROWAVE. A Spectrum Control Business

ytivac Cavity Filters

Optiva OTS-2 40 GHz Amplified Microwave Band Fiber Optic Links

Using the OML Millimeter Wave Vector Network Analyzer Frequency Extension Modules with the HP 8510 Vector Network Analyzer

Designed and Manufactured in England to the highest standards

Block Upconverters for Integration in High Power Amplifiers

Optiva OTS-2 18 GHz Amplified Microwave Band Fiber Optic Links

SC5307A/SC5308A 100 khz to 6 GHz RF Downconverter. Datasheet SignalCore, Inc.

FS5000 COMSTRON. The Leader In High Speed Frequency Synthesizers. An Ideal Source for: Agile Radar and Radar Simulators.

MICROWAVE ASSEMBLIES, SYSTEMS AND TECHNOLOGIES

ModBox - Spectral Broadening Unit

Who We Are. Antennas Space Terahertz

325 to 500 GHz Vector Network Analyzer System

Data Sheet SC5317 & SC5318A. 6 GHz to 26.5 GHz RF Downconverter SignalCore, Inc. All Rights Reserved

Features. Upconversion & Downconversion Applications MIXERS - SINGLE & DOUBLE BALANCED - SMT

Optiva OTS-2 40 GHz Amplified Microwave Band Fiber Optic Links

Dinesh Micro Waves & Electronics

and GHz. ECE Radiometer. Technical Description and User Manual

FMMX9003 DATA SHEET. Field Replaceable SMA IQ Mixer From 11 GHz to 16 GHz With an IF Range From DC to 3.5 GHz And LO Power of +19 dbm.

SIGNAL GENERATORS. MG3633A 10 khz to 2700 MHz SYNTHESIZED SIGNAL GENERATOR GPIB

Holography Transmitter Design Bill Shillue 2000-Oct-03

QuickSyn Frequency Synthesizers

1:1 AND 1:2 REDUNDANT LOW-NOISE AMPLIFIER SYSTEMS

Platform Migration 8510 to PNA. Graham Payne Application Engineer Agilent Technologies

A Broadband T/R Front-End of Millimeter Wave Holographic Imaging

Chapter 5 Specifications

Keysight Technologies E8257D PSG Microwave Analog Signal Generator. Data Sheet

CHAPTER - 6 PIN DIODE CONTROL CIRCUITS FOR WIRELESS COMMUNICATIONS SYSTEMS

CMOS 5GHz WLAN ac RFeIC WITH PA, LNA AND SPDT

DS H01 DIGITAL SYNTHESIZER MODULE SYSTEM SOLUTIONS. Features Applications 174 x 131 x 54 mm. Technical Description

CORRY MICRONICS, INC. 761 COMMONWEALTH DRIVE SUITE 201 WARRENDALE, PA P F

Transcription:

sales@vivatech.biz Telephone: +33 (0)4 89 01 14 61 Fax: +33 (0)4 93 87 08 66

TABLE OF CONYENTS Frequency Sources - Multiplier Chain... 3 Frequency Sources VCO / PLO Based... 4 Portable Millimeter Wave / THz Transmitter & Receivers... 5 VNA Frequency Extenders TR-R and TR-TR Sets... 6 Millimeter Wave / THz Down Converters... 8 Millimeter Wave Noise Measurement Converters... 9 Solid State Noise Source... 10 Amplifiers - Low Noise Amplifiers... 11 Amplifiers - Power Amplifiers... 12 Mixers - Fundamental Balanced Mixers... 13 Mixers - Low Noise Sub Harmonic Mixers... 14 Mixers - Full Band Waveguide Harmonic Mixers... 15 Attenuators - Full Band Waveguide Variable & Fixed... 16 Detectors - Full Waveguide Band... 17 Isolators - Full Waveguide Band... 18 Couplers - Full Waveguide Band... 19 Probes Millimeter / THz Near Field Probes... 20 Antennas - Waveguide Pyramidal Horn... 21 Antennas - Waveguide Diagonal Horn Antennas... 22 Antennas - Lens Horn Antennas... 23 Antennas - Waveguide Corrugated Horn... 24 Low Pass Filters... 25 Band Pass & Band Stop Filters... 26 High Pass Filters... 27 Precision Waveguide Straight Sections... 28 Precision Waveguide Bends & Twists... 29 Precision Waveguide Short & Terminations... 30 Precision Waveguide Transitions... 31 Cryogenic Primary Noise Standard... 32 2

Frequency Sources - Multiplier Chain VTXFA-10FBH Output Power, GHz Plug n Play: just add DC power and RF microwave input Coverage: 50 500 GHz Standard waveguide full-band & narrow-band Ideal signal generator or frequency extender High output power Standard or custom input power levels Flat frequency response Optional output isolators (up to 220 GHz) Compact, fully screened enclosure with integral heat sink VTXFA-15FB VTXFA-15HA VTXFA-12FB VTXFA-12HA VTXFA-12HB VTXFA-10FB VTXFA-10FBH VTXFA-08FB VTXFA-06FB VTXFA-05FB VTXFA-04H VTXFA-03FB VTXFA-2.2FB Output Frequency (GHz) 50 70 60 90 67 87 68 78 90 140 210 224 220 330 325 500 Waveguide WR 12 WR 12 WR 12 WR 04 WR 2.2 Input Frequency (GHz) 8.33 12.50 8.33 11.67 10.00 15.00 11.16 14.50 11.33 13.00 12.50 18.33 12.50 18.33 15.00 23.30 9.17 14.17 11.66 18.34 17.50 18.67 12.20 18.10 9.02 13.89 Output Power (dbm) +3, +6 +15 typical +3, +5 +13 typical +20 typical +3, +6 +13, +16 +6 typical +6 min, +10 typical +4 typical +10, +12-7, -5-10, -8 1. RF input power: +7 to +10 dbm 2. Harmonic and spurious: < 20 dbc typical 3. DC: +7 to +9 VDC, < 1 A typical 4. Input connector: SMA (F) or K (F) 5. How to make a request: specify above, or input and output frequencies, output power desired, waveguide size, and isolator if required; email to: sales@vivatech.biz 3

Frequency Sources VCO / PLO Based GHz VCO Output Power Typical Performance Frequency coverage: 50 - > 670 GHz Analog/Digital tuned VCO driven multiplier chains State of art power output Optional output isolator (up to 220 GHz) VCO as standard, other fundamental sources eg. YIG, Synthesizer can be chosen to suit application Fully integrated miniature versions Frequency (GHz) Waveguide Power Output (dbm) VTVCO-15FB VTVCO-10FB VTVCO-06FB VTVCO-05FB VTVCO-03FB VTVCO-1.5NB 220 325 656-672 WR 1.5 +7 to +10 +10 to +13-2 to +4-10 to -5-12 to -8-10 to -15 Frequency Accuracy % -1 +/- 0.15 +/- 0.15 +/- 0.15 +/- 0.20 +/- 0.20 +/- 5 ppm Power Flatness (db) +/- 1 +/- 1 +/- 1 +/- 2 +/- 2 +/- 3 1. Based on a multiplied internal free running VCO oscillator, integrated with the source 2. DC power required is + 12-15V, 1-2 A depending on model 3. VCO tuning voltage is typically in the range 0-16 V DC 4. Digitally tuned versions are available to specification, based on an integrated or external synthesizer 5. Sizes from 45 x 50 x 20 mm, excluding heat sink 6. How to make a request: specify waveguide size, frequency range, frequency accuracy, output power and flatness, email to: sales@vivatech.biz 4

Portable Millimeter Wave / THz Transmitter & Receivers Extend portable VNA s to mm-wave and THz Coverage 50-670 GHz in custom bands Extends VNA s without LO/IF access Synchronous frequency and sweep operation Fully compatible with Keysight Fieldfox portable VNA and various Anritsu models Radar, communications and antenna test applications Complementary to Source Modules see Page 5 Compact & Portable RF Input / Output Frequency (GHz) VNA RF Frequency (GHz) VNA RF Power (dbm) Transmit Power (dbm) RX Noise Figure (db); typical RX Conversion Gain, db Maximum RF CW Input Power (dbm) LO /IF Connector RF Connector BUC/BDC-15S* 54-72 2-20 Anritsu +6 < 15.0 7.0 min, 10.0 max +3 (2 mw) SMA/K (F) WR15; UG385/U BUC/BDC-10S* 87-105 2-20 Anritsu +10 < 15.0 7.0 min, 10.0 max +3 (2 mw) SMA/K (F) WR10; UG387/U Portable 300 GHz Extender System with Fieldfox VNA BUC/BDC-03S** 280 320 4-20 FieldFox -14 < 15.0 10.0 typical +0 (1 mw) SMA/K (F) WR03; UG387/U BUC/BDC-1.5S** 656-672 4-20 FieldFox -10 < 20.0 10.0 typical -10 (0.1mW) SMA/K (F) WR1.5; UG387/U 1. **Compatible with Keysight Portable VNA FieldFox 26.5 GHz/40 GHz s N9918A, N9950A 2. *Compatible with Anritsu MS46122A Shockline compact VNA 3. Transmitter receiver pair measures S21 (transmission) phase and amplitude 3. S11 requires a separate directional coupler, optional 4. Other frequency ranges on request 5. How to make a request: state required frequency range, extender No, VNA and its options, email to: sales@vivatech.biz 5

VNA Frequency Extenders TR-R and TR-TR Sets Frequency Coverage: 50 >500 GHz in standard waveguide bands Broadband high output power with low ripple Full 2 way S parameters with 2 x TR modules or economical TR-R combinations Compatible with standard benchtop microwave VNA / PNA test equipment Customizable for antenna test and other applications State of art dynamic range Optional level set attenuators Flexible height and levelling adjustments VivaTech s TR-R Modules with Keysight VNA / PNA WR15 Full Band TR-R Dynamic Range WR10 Full Band TR-R Dynamic Range WR06 Full Band TR-TR Dynamic Range 6

VNA Frequency Extenders TR-R and TR-TR Sets (Cont ) VTWR06-TR-TR Dynamic Range & Power Output TR, Transceivers RF Frequency (GHz) Test Port Output Power (dbm) Coupler Directivity (db) R, Receiver RF Frequency (GHz) Test Port Input Power 1 db GCP (dbm) Dynamic Range (db) -1; min, typical Attenuator Adjustment (db); min Performance Specification of TR Modules VTWR15-TR VTWR10-TR VTWR06-TR 13; minimum 8; minimum +3 ; minimum 15; typical 10; typical +6 ; typical 35 ; minimum 34 ; minimum > 40; typical >36; typical VTWR05-TR VTWR03-TR 220 330-10; typical -15; typical 30 ; minimum >35; typical Performance Specification of R Module and TR-R Combination VTWR15-R VTWR10-R VTWR06-R VTWR05-R +3; typical 0; typical -10; typical 110 120 105 120 85 105 30 [Option : can be fitted to one or both modules] VTWR03-R 220 325 90 100 VTWR2.2-TR 330-500 -25 typical > 30 typical VTWR2.2-R 330-500 -20 80-90 1. Dynamic range refers to TR_TR pair for S-parameter measurement, including typical noise in user instruments. Measured with 10 Hz IF BW 2. An external interface module is required in some cases to interface the modules with standard VNA / PNA models. Consult us for details 3. Standard product dimensions are 140 x 100 x 160 mm [R Module] and 230 x 100 x 308 mm [TR Module] 4. How to make a request: Select above, specify manufacturer and model number of the PNA/VNA to be used, email to: sales@vivatech.biz 7

Millimeter Wave / THz Down Converters Coverage 26.5-670 GHz Broadband sensitive receivers for spectrum analysis Linear converters for Keysight Fieldfox portable VNA Extend Noise Figure measurements to millimeter wave Complementary to Source Modules for Transmission and Radar measurements, see Page 5 Custom designs RF Frequency (GHz) LO Frequency (GHz) LO Power (dbm) IF Frequency (GHz) Noise Figure (db); typical Conversion Gain/ Loss1, db Maximum RF CW Input Power (dbm) LO /IF Connector RF Connector BDC- KH 26.5 40 14.40-3.0 3.2-16.7 10.5 9 min, 12 typical +13 (20 mw) SMA/K (F) K SMA(F) BDC-12SA* 70 83 Internal Internal 4.5-18 < 15.0 15 typical, 18 db maximum 0 (1 mw) Internal WR12; UG387/U BDC-10-798 75 83 Internal Internal 4-12 8.5 15 minimum 18 typical +3 (2 mw) Internal WR10; UG387/U BDC-08S 100 124 16-20 +10 0.01-7.0 < 10.0 BDC-03S** 280 320 FieldFox FieldFox FieldFox < 15.0 BDC-1.5S** 656-672 FieldFox FieldFox FieldFox < 20.0 7.0 min, 10.0 max1 10.0 typical 10.0 typical 0 (1 mw) SMA/K (F) WR08; UG387/U +0 (1 mw) SMA/K (F) WR03; UG387/U +0 (1mW) SMA/K (F) WR1.5; UG387/U 1. A variety of designs exist, of which only some samples are shown 2. Local oscillator can be internal or externally provided. State required phase noise and stability if required internally. 3. Frequency plan depends on final selection of harmonic numbers 4. See Fullband Waveguide Harmonic Mixers for unpackaged solutions and other frequency bands as shown in VTHM series at page 10 of this catalogue 5. *Compatible with Agilent Noise Figure Analyzers eg. N8975A 6. **Compatible with Keysight Portable VNA FieldFox 26.5 GHz/40 GHz N9927 when using companion Upconverter Module 7. How to make a request: provide No and details of RF, LO and IF ranges, advise required gain and noise figure, email to: sales@vivatech.biz 8

Millimeter Wave Noise Measurement Converters Full band coverage : 40-170 GHz in waveguide bands Compatible with standard noise figure analyzers1 Swept frequency measurement Extend Noise Figure measurements to millimeter wave Use external microwave signal generator Compatible solid state noise source available VTBDC-19FBE VTBDC-15FBE VTBDC-12FBE VTBDC-10FBE VTBDC-08FBE VTBDC-06FBE RF Frequency (GHz) 40-60 50-75 60-90 75-110 90-140 110-170 LO Frequency (GHz) 10.0-15.0 8.33-12.5 10.0-15.0 12.5-18.33 7.5-11.67 9.17-14.17 Noise Source ENR (db) typical 13.0 +/- 1.5 13.0 +/- 1.5 13.0 +/- 1.5 12.0 +/- 1.5 12.0 +/- 2.0 12.0 +/- 2.5 Test Range NF/Gain (db) NF: 0 20 Gain: -20 to +30 Waveguide Interface WR19, UG 383/U WR15, UG 385/U-M WR12, WR10, WR08, WR06, Typical Measured Gain & NF, GHz 1. Keysight N8975A/B and others. 2. LO/IF connectors SMA-F. 3. IF output 10 MHz to 1 GHz as standard. 4. Overall gain is 30 db typical; NF is < 12 db typical to 20 db maximum 5. How to make a request: provide No, email to: sales@vivatech.biz 9

Solid State Noise Source Coverage 40-170 GHz High ENR with calibration table Matches VivaTech Noise Figure Downconverters* Automatic control with Keysight N8975A/B or similar Number VTNS-19FB VTNS-15FB VTNS-12FB VTNS-10FB VTNS-08FB VTNS-06FB Frequency Range (GHz) 40-60 50-75 60-90 75-110 90-140 110-170 ENR, db (nom) 13 13 13 12 12 12 ENR Flatness, db (typ) +/- 1.5 +/- 1.5 +/- 1.5 +/- 2.0 +/- 2.0 +/- 2.5 Waveguide Band WR 19 WR 12 Waveguide Flange UG383/U-M UG385/U UG387/U-M UG387/U-M UG387/U-M UG387/U-M 1. Calibrated with Hot/Cold load 2. DC bias +18 to +28 V DC < 100 ma 3. Modulation frequency < 1 KHz square wave. 4. Fitted with full band isolator 5. *Compatible with Agilent Noise Figure Analyzers eg. N8975A/B 6. How to make a request: provide No, email to: sales@vivatech.biz Nosie Figure Test Set Consisting of VivaTech Solid State Noise Source and Noise Measurement Converters Shown in Page 9 of This Catalog 10

Amplifiers - Low Noise Amplifiers WR06 Full Band Measured Noise Frequency coverage: 50 350 GHz Available for full waveguide and narrow bandwidth Low noise High P-1dB Low power consumption SMA or K connectors are available for certain models VTLNA 15FB VTLNA 10FB VTLNA-10FBH VTLNA 08S VTLNA 06S VTLNA 2.8NB S01 Frequency (GHz) 50-75 100-130 250-350 Connector WR 2.8-1 Gain (db) 15 typical 18 typical 40 typical 15 minimum 18 typical 25 typical Noise Figure (db) 4.0 typical 3.5 typical 3.5 typical 5.5 typical 4 to 5 typical @ 140 GHz 10.0 typical @ 300 GHz WR06 Full Band Measured S-Parameters 1. Also available in WR03 interface 2. s below 50 GHz are available on request 3. How to make a request: select one of the s above, or provide specifications including frequency range, noise figure, gain, and waveguide size; send email to: sales@vivatech.biz 11

Amplifiers - Power Amplifiers WR10 Full Band Power Output Measured Frequency coverage: 26.5 110 GHz Up to 1W output Broadband coverage Miniature designs High reliability, MMIC based K connectors with certain models Custom designs on request Sample VTPA-28FB VTPA-22FB VTPA-15NB-S01 VTPA-15NB-S02 VTPA-12NB-S01 VTPA-12NB-S02 VTPA-12NB-S03 VTPA-10NB-S02 VTPA-10FB-S03 Frequency (GHz) 26.5 40 33 50 50 70 58 66 68-78 67 87 74 80 78 90 Connector WR 28 WR 22 or V WR 12 WR 12 WR 12 Gain (db) 30 minimum 19 typical 24 minimum 25 minimum 23 typical 16 minimum 10 typical 10 typical 18 typical PSAT (dbm) 30 (P-1) 19 17 typical 19 20 typical 14 typical 20 typical 20 typical 20 typical WR10 Full Band S Parameters Measured : 1. How to make a request: Select one of the s above, or provide specifications including frequency range, output P-1dB or PSAT, gain, and waveguide size, send mail to: sales@vivatech.biz 12

Mixers - Fundamental Balanced Mixers VTBM-06; Conversion Loss Frequency coverage: 25 >170 GHz No tuning required Wide IF bandwidths Lowest conversion Loss Low LO power biased versions Frequency (GHz) VTBM-28-FB 26.5 40 VTBM-15-FB VTBM-12-FB VTBM-10-FB VTBM-08 VTBM-06 60-90 90 140 Frequency Coverage RF / LO IF Bandwidth; Typical Conversion Loss -1 (db); Typical LO Power (dbm) -2 <6 Up to 10% for narrow band version Or full waveguide bandwidth (*except WR08 and WR06 mixers) Up to 20 GHz for narrow band or fixed LO models Limited to approx. 4 GHz for fullband RF/LO models <7 < 7.5 <8 < 10 < 12 +10 to +13 1. Value depends on exact RF/LO/IF frequencies, and LO power. (*Full band RF/LO 90-140 and 110-170 GHz mixers are not available) 2. Low LO power, DC biased, Narrow and Full Band Mixers are also available as custom products, contact factory 3. For complete custom and standard down-converters see Page 23 of this catalogue 4. How to make a request: select one of s above, or provide specifications including waveguide sizes, RF frequency range, IF frequency range, LO frequency range, conversion loss, available LO power, and external or internal bias desired, email to: sales@vivatech.biz 13

Mixers - Low Noise Sub Harmonic Mixers VTSHM-05 Conversion Loss VTSHM-05 Conversion loss (db) 10 Frequency coverage: Up to 670 GHz Very low conversion loss and noise Zero bias operation Balanced design Wide IF bandwidths [with fixed LO] LO at ½ RF 8 6 4 Conversion loss db DSB 2 0 180 185 190 195 200 205 Frequency (GHz) RF Frequency (GHz) LO Frequency (GHz) VTSHM-06A VTSHM-06B VTSHM-05A VTSHM-05B VTSHM-03A VTSHM-03B VTSHM-03C VTSHM-02A VTSHM-1.5 110 165 130 170 167 200 185 230 265 295 275 330 310 340 380 440 656-672 55 83 65 85 83 100 93 115 132 148 137 165 155 170 190 220 330 Conversion Loss (db); Typical 6 6 6 6 7 7 8 9 12 Max IF Bandwidth (GHz) 20 16 16 18 18 18 18 20 20 Maximum RF Power (dbm) -1 +6 0 / +6 0 / +6 0 / +6-5 -5-5 -10-10 RF Input Waveguide LO Input Waveguide WR 02 WR 1.5 WR 12 WR 12 WR 04 1. Mixers with integrated IF amplifiers are available as an option 2. No DC bias or RF/LO diplexer required 3. Performance approaching fundamental mixers with lower system costs 4. How to make a request: select one of the s above, or provide specifications including waveguide sizes, RF frequency range, IF frequency range, LO frequency range, conversion loss, and available LO power, email to: sales@vivatech.biz 14

Mixers - Full Band Waveguide Harmonic Mixers Frequency coverage: 26 500 GHz Waveguide full bandwidth as standard Zero bias, common or separate LO / IF ports General purpose frequency extension for Spectrum Analyzers / Systems Even mixing harmonics RF Frequency (GHz) 40 60 60 90 90 140 220 325 VTWHM-19 VTWHM-15 VTWHM-12 VTWHM-10 VTWHM-08 VTWHM-06 VTWHM-05 VTWHM-03 Conversion Loss (db) -1 15 to 20 20 to 25 20 to 29 20 to 25 30 to 35 35 to 40 35 to 40 45 to 55 LO Frequency (GHz) Maximum 16 18 18 18 18 20 18 18 RFMAX (dbm) 0 / +6 0 / +6-5 -5-5 -10-10 -5 Waveguide WR 19 WR 12 1. Conversion loss, LO range 8-18 GHz @ +13 dbm, IF DC - 2 GHz; actual value depends on harmonic number 2. LO/IF bandwidths up to 18 GHz. Common or separate LO/IF ports. No DC bias required 3. s >325 GHz are available, contact factory 4. How to make a request: specify waveguide sizes, RF frequency range, IF frequency range, LO frequency range, conversion loss, harmonic number, and available input power, email to: sales@vivatech.biz 15

Attenuators - Full Band Waveguide Variable & Fixed Full band coverage: 33 325 GHz Low loss at zero setting [variable version] Low VSWR High accuracy Fully Calibrated : 5 db intervals, full-band (Variable Attenuator) -1 VTWG-ATT-22 VTWG-ATT-15 VTWG-ATT-10 VTWG-ATT-08 VTWG-ATT-06 VTWG-ATT-05 VTWG-ATT-03 Frequency (GHz) 33 50 90-140 220 325 Insertion Loss (db); Typical < 0.3 < 0.5 < 0.5 < 0.5 < 0.5 < 0.5 < 1.2 Attenuation (db) Waveguide 0 to 25 minimum WR 22 (Fixed Attenuator) VTWG-ATT-22-XX VTWG-ATT-15-XX VTWG-ATT-10-XX VTWG-ATT-08-XX VTWG-ATT-06-XX VTWG-ATT-05-XX VTWG-ATT-03-XX 0 to 40 Frequency (GHz) 33 50 90 140 220 325 Insertion Loss (db); Typical < 0.3 < 0.5 < 0.5 < 0.5 < 0.5 < 0.5 < 1.2 Attenuation (db) Waveguide -XX -1 WR 22 1. Attenuation range: 0 to 40 db 2. Typical - fixed 10 db attenuator 3. How to make a request: select one of the s above, or provide specifications including frequency range, insertion loss, attenuation value for the fixed attenuator, attenuation range for the variable attenuator, and waveguide size, email to: sales@vivatech.biz 16

Detectors - Full Waveguide Band Typical WR3 Full Band Sensitivity Performance Full band coverage Zero bias operation No mechanical tuner Calibrated Frequency (GHz) VTWD-15-FB VTWD-10-FB VTWD-08-FB VTWD-05-FB VTWD-03-FB 90 140 220 325 Sensitivity -1 (mv / mw) > 500 > 750 > 250 > 100 1750 Input RF Power (dbm); Maximum 0 0-10 -10-10 Waveguide 1. Typical value specified with -20 dbm input power and 1 Mohm load 2. Output connector: SMA(F) 3. Video bandwidth; up to 18 GHz, depends on load impedance 4. Custom design available upon request 5. How to make a request, select one of s above, or provide specifications and email to: sales@vivatech.biz 17

Isolators - Full Waveguide Band Typical 90-140 GHz Full-Band Performance Full band coverage Compact Lowest insertion loss in industry Low VSWR High isolation Available up to 220 GHz WGISO-VFB WGISO-WFB WGISO-FFB WGISO-DFB WGISO-GFB Frequency (GHz) 90 140 Insertion Loss (db); Typical 1.3 1.3 1.5 1.8 1.5, 2.3 max Isolation (db); Typical > 20 > 20 > 20 > 20 > 20 Waveguide, Flange, UG 385/U, UG387/U-M,,, : 1. How to make a request: Select one of models above, or provide specifications including frequency range, insertion loss, isolation, and waveguide size, send email to: sales@vivatech.biz 18

Couplers - Full Waveguide Band W Band Full-Band 20 db Coupler Typical Performance 0 Frequency coverage: 50 500 GHz Full waveguide band available Low loss Various directivities 3-port or 4-port models Fully Calibrated 0-5 -10-10 -20-15 -30-20 -40-25 -50-30 -60 75 80 Loss, db VT-WGC-15 VT-WGC-10 VT-WGC-08 VT-WGC-06 VT-WGC-05 VT-WGC-04 VT-WGC-03 VT-WGC-2.2 Frequency (GHz) 90 140 140-220 170 260 220 325 325-500 Directivity (db) Loss & Coupling (db) 85 90 95 100 105 110 Frequency, GHz Coupling, db Directivity, db Insertion Loss, typ (db) 0.75 0.9 1.1 1.2 1.5 1.7 2.2 3.5 Directivity (db); Minimum 35 35 30 25 25 25 25 30 typical Coupling (db) 10 to 40-1 Waveguide WR 04 WR 2.2 1. Coupling values available depend on frequency band selected 2. Dual couplers with internal terminations are available upon request 3. How to make a request: select one of the s above, or provide specifications including frequency range, waveguide size, coupling value, directivity, and number of ports, email to: sales@vivatech.biz 19

Probes Millimeter / THz Near Field Probes : Frequency coverage: 50 1100 GHz Near Field Scanning Applications Standard waveguide interfaces Quasi-uniform main beam Precision machining Custom designs Frequency (GHz) VTWGP-15-XX VTWGP-10-XX VTWGP-08XX VTWGP-06XX VTWGP-05XX VTWGP-04XX VTWGP-03XX VTWGP-2.8XX VTWGP-2.2XXS VTWGP-1.5XX VTWGP-1.0RS 90 140 170 260 225 325 260 400 330 500 500 750 750-1100 Standard Length, mm 100.0 100.0 100.0 100.0 50.0 50.0 50.0 35.0 35.0 35.0 25.0 VSWR, typical < 1.1 < 1.1 < 1.1 < 1.2 < 1.2 < 1.25 < 1.5 < 1.5 < 1.75 < 1.75 < 1.75 Waveguide WR 04 WR 2.8 WR 2.2 WR 1.5 WR 1.0 WR1.5 Waveguide Probe 1. Suffix XX denotes length. Standard lengths are shown above. Custom lengths available. 2. Flange types above 110 GHz (WR10) may vary. Specify your flange requirement above WR10. 3. Probe material is copper or copper alloy gold plated. Simulated Pattern VTWGP-03-50 20

Antennas - Waveguide Pyramidal Horn WR10 Standard Gain Horn 500 750 GHz Standard Horn VTAP-1.5RS Frequency coverage: 50 1100 GHz Broadband with full waveguide bandwidth Standard gain horns Predictable characteristics Solid and robust construction Frequency (GHz) VTAP-15RS VTAP-12RS VTAP-10RS VTAP-08RS VTAP-06RS VTAP-05RS VTAP-04RS VTAP-03RS VTAP-2.8RS VTAP-2.2RS VTAP-1.5RS VTAP-1.0RS 60 90 90 140 170 260 225 325 260 400 330 500 500 750 750-1100 Gain (db), nominal at Midband 24.0 24.0 24.0 24.0 24.0 24.0 24.0 24.0 24.0 24.0 24.0 24.0 VSWR, typical Waveguide < 1.1 < 1.1 < 1.1 < 1.1 < 1.2 < 1.2 < 1.25 < 1.25 < 1.4 < 1.5 < 1.5 < 1.5 WR 12 WR 04 WR 2.8 WR 2.2 WR 1.5 WR 1.0 WR12 Radiation Pattern 1. Standard horns have 24 dbi gain at mid band. Other gains are available to order. 2. Flange types above 110 GHz (WR10) may vary. Specify your flange requirement above WR10. 3. Material is copper or copper alloy gold plated. 4. s machined from solid Aluminium available. 21

Antennas - Waveguide Diagonal Horn Antennas Frequency coverage: 220 1100 GHz Broadband with full waveguide bandwidth Near Gaussian characteristics Predictable characteristics Solid and robust construction Simplified manufacturing VTAP-05DS VTAP-04DS VTAP-03DS VTAP-2.8DS VTAP-2.2DS VTAP-1.5DS VTAP-1.0DS Frequency (GHz) 170 260 225 325 260 400 330 500 500 750 750-1100 500-750 GHz Diagonal Horn VTAP-1.5DS Gain (db), nominal at Mid-band 25.0 25.0 25.0 25.0 25.0 25.0 25.0 HPBW, typical 8 deg 8 deg 8 deg 8 deg 8 deg 8 deg 8 deg Waveguide WR 04 WR 2.8 WR 2.2 WR 1.5 WR 1.0 Flange, anti-cocking type 1. Diagonal horns have antenna patterns close to Gaussian beams and are easier to manufacture than corrugated or conical horns. 2. Standard diagonal horns have 25 dbi gain at mid band. Other gains are available to order. 3. Flange types above 110 GHz (WR10) may vary. Specify your flange requirement above WR10. 4. These models are machined from solid Aluminium. 22

Antennas - Lens Horn Antennas Frequency coverage: 50 500 GHz Pencil beam and asymmetric beams Radar Imaging Communications Custom Designs VTA-HL-15SNB VTA-HL-15SAB VTA-HL-10SNB VTA-HL-10SAB VTA-HL-06SNB VTA-HL-06SAB VTA-HL-05SNB VTA-HL-05SAB VTA-HL-03SNB VTA-HL-03SAB Frequency (GHz) 50-75 75-110 110-170 220 325 220-325 Type Gain (db) Pencil beam Assymetric Pencil beam Assymetric Pencil beam Assymetric Pencil beam Assymetric Pencil beam Assymetric >25 typical custom >25 typical custom >25 typical custom >25 typical custom >25 typical custom Beamwidth (E/H) deg1 1-5 1-5, 10-20 1-5 1-5, 10-20 1-5 1-5, 10-20 1-5 1-5, 10-20 1-5 1-5, 10-20 300 GHz Pencil Beam Antenna Waveguide, Flange WR15, UG385/U-M WR15, UG385/U-M WR10, UG387/U-M WR10, UG387/U-M WR06, UG387/U-M WR06, UG387/U-M WR05, UG387/U-M WR05, UG387/U-M WR05, UG387/U-M WR05, UG387/U-M 1. Nominal, mid band, varies with frequency. Other values are available to order. 2. Flange types above 110 GHz (WR10) may vary. Specify your flange requirement above WR10. 3. Other frequency ranges are available to order. 4. Material is copper or copper alloy gold plated, excluding lens. 5. How to make a request: Specify center frequency, 3 db E/H beam width, waveguide size, gain, any other requirements, email to: sales@vivatech.biz Sectoral Lens Horn Antenna with broad E beam and narrow H beam 23

Antennas - Waveguide Corrugated Horn Frequency coverage: 18 325 GHz Broadband with full waveguide bandwidth coverage (some models) E-H plane symmetry Exceptionally low cross polarization Measured E-H Antenna Patterns at 18 GHz Measured E-H Antenna Patterns at 89 GHz 1. Corrugated horn antennas are customized to user requirements 2. How to make a request: Specify center frequency, 3 db beam width, waveguide size, gain, any other requirements; email to: sales@vivatech.biz 24

Low Pass Filters Coverage 50 325 GHz Custom specifications Low loss High rejection Fully modelled performance predictions Frequency Range (GHz) VTLPF-15 VTLPF-10 VTLPF-08 VTLPF-05 VTLPF-03 90 140 220 325 Pass Band Loss (db); Typical < 1.0 < 1.0 < 1.0 < 1.5 < 2.0 Rejection Band (db); Typical Waveguide 40 VTLPF-06 Performance : 1. How to make a request: Select one of the s above, and provide specifications including pass band frequency, pass band loss, reject band frequency and attenuation, and waveguide size; email to: sales@vivatech.biz 25

Band Pass & Band Stop Filters VTBPF-03NB Band Pass Filter 290-315 GHz Frequency coverage: 50 325 GHz Custom specifications Band Pass or Band Stop (Notch Filters) High rejection Fully modelled performance predictions VTBPF-15 VTBPF-10 VTBPF-08 VTBPF-06 VTBPF-05 VTBPF-04 VTBPF-03 Frequency Range (GHz) 90 140 170 260 220 325 Pass Band Loss (db); Typical <1 <1 <1 <1 < 1.5 < 2.5 < 3.5 Rejection Band (db); Typical Waveguide > 40 WR 04 : 1. How to make a request: Select one of the s above, and provide specifications including pass band frequency, pass band losses, reject band frequency, reject band attenuation, and waveguide size; email to: sales@vivatech.biz 26

High Pass Filters Coverage 50 325 GHz Custom specifications Low pass band loss High rejection Fully modelled performance predictions VTHPF-15 VTHPF-10 VTHPF-08 VTHPF-06 VTHPF-05 VTHPF-04 VTHPF-03 Frequency Range (GHz) 90 140 170 260 220 325 Pass Band Loss (db); Typical < 1.0 < 1.0 < 1.0 < 1.0 < 1.0 < 1.0 < 1.5 Rejection Band (db); Typical Waveguide > 40 WR 04 VTHPF-06 Test Data : 1. How to make a request: Select one of the s above, and provide specifications including pass band frequency, pass band loss, reject band frequency, reject band attenuation, and waveguide size; email to: sales@vivatech.biz 27

Precision Waveguide Straight Sections Frequency coverage : up to 1.1 THz Extremely robust alternative to drawn waveguide High precision Custom length Lowest loss in industry VTWG-10-xx VTWG-08-xx VTWG-06-xx VTWG-05-xx VTWG-04-xx VTWG-03-xx VTWG-2.8-xx VTWG-2.2-xx VTWG-1.5-xx VTWG-1.0-xx Waveguide Designation WR 04 WR 2.8 WR 2.2 WR 1.5 WR 1.0 Measured Insertion Loss, 750 1100 GHz, WR1.0 Waveguide New IEEE Waveguide Designation WM-2540 WM-2022 WM-1651 WM-1295 WM-1092 WM-864 WM-710 WM-570 WM-380 WM-250 Standard Flange-2 Frequency Coverage (GHz) 90 140 170 260 220 330-3 260 400 330 500 500 750 750-1100 1. New definitions for use above 110 GHz have been proposed by IEEE in order to define standards up to 1.1 THz. 2. There are variations in industry 'standard' flanges. When ordering waveguides > 100 GHz advise required flange PIN and hole dimensions 3. Waveguide historically covers 220-325 GHz however the new standard WM-864 extends coverage to 220 330 GHz 4. Standard waveguides are 25 mm long and manufactured in solid brass gold plated. Also available ; other lengths and materials such as OFHC copper for cryogenic applications. 5. How to make a request: specify number with required length eg. VTWG-1.5-50 is waveguide straight section in WR1.5 of length 50 mm. Email to : sales@vivatech.biz 28

Precision Waveguide Bends & Twists Frequency coverage: up to 1100 GHz High precision Custom length possible Low loss Extremely robust E Plane 90o Bend VTWGE-10 VTWGE-08 VTWGE-06 VTWGE-05 VTWGE-04 VTWGE-03 VTWGE-2.8 VTWGE-2.2 VTWGE-1.5 VTWGE-1.0 H Plane 90o Bend VTWGH-10 VTWGH-08 VTWGH-06 VTWGH-05 VTWGH-04 VTWGH-03 VTWGH-2.8 VTWGH-2.2 VTWGH-1.5 VTWGH-1.0 Twist 90o VTWGTW-10 VTWGTW-08 VTWGTW-06 VTWGTW-05 VTWGTW-04 VTWGTW-03 VTWGTW-2.8 VTWGTW-2.2 VTWGTW-1.5 VTWGTW-1.0 Waveguide Designation WR 04 WR 2.8 WR 2.2 WR 1.5 WR 1.0 New IEEE Waveguide Designation WM-2540 WM-2022 WM-1651 WM-1295 WM-1092 WM-864 WM-710 WM-570 WM-380 WM-250 Standard Flange-2 Frequency Coverage (GHz) 90 140 170 260 220 330-3 260 400 330 500 500 750 750-1100 1. New definitions for use above 110 GHz have been proposed by IEEE in order to define standards up to 1.1 THz. 2. There are variations in industry 'standard' flanges. When ordering waveguides > 100 GHz advise required flange PIN and hole dimensions 3. Waveguide historically covers 220-325 GHz however the new standard WM-864 extends coverage to 220 330 GHz 4. How to make a request: specify number. Standard bends have effective length 37.5 mm, twists 25 mm. Email to: sales@vivatech.biz 29

Precision Waveguide Short & Terminations Frequency coverage: up to 325 GHz High precision Calibration Standards Physically extremely robust Shown opposite are waveguide shorts/termination Waveguide Designation VTWGT-15 VTWGT-12 VTWGT-10 VTWGT-08 VTWGT-06 VTWGT-05 VTWGT-04 VTWGT-03 VTWGT-2.8 WR 12 WR 04 WR 2.8 New IEEE Waveguide Designation WM-2540 WM-2022 WM-1651 WM-1295 WM-1092 WM-864 WM-710 WM-570 WM-380 VSWR typical Standard Flange Frequency Coverage (GHz) < 1.25 : 1 < 1.25 : 1 < 1.25 : 1 < 1.25 : 1 < 1.5 : 1 < 1.5 : 1 < 1.5 : 1 < 1.5 : 1 < 1.5 : 1 UG 385/U UG 387/U 60 90 90 140 170 260 220 330-3 260-400 1. New definitions for use above 110 GHz have been proposed by IEEE in order to accommodate standards up to 1.1 THz. 2. There are variations in industry 'standard' flanges. When ordering waveguides > 100 GHz advise required flange PIN and hole dimensions 3. Waveguide historically covers 220-325 GHz however the new standard WM-864 extends coverage to 220 330 GHz 4. How to make a request: specify number, email to sales@vivatech.biz 30

Precision Waveguide Transitions WAVEGUIDE PORT 2 WR28 WR28 WR22 WR19 WR15 WR12 WR10 WR08 WR06 WR05 WR04 WR03 WR2.8 WR2.2 WR1.5 WR22 WR19 WR15 WR12 WR10 WAVEGUIDE PORT 1 WR08 WR06 WR05 WR04 WR03 WR2.8 WR2.2 WR1.5 Waveguide transitions allow interconnections between differing waveguide sizes eg. WR10 to WR8 Waveguide transitions are available for any combination from WR28 to WR1.5 Made to order, these transitions feature precision machining from solid copper alloy, a gold plated finish and a choice of flanges 1. How to make a request: use model # VTST WAVEGUIDE PORT 1- WAVEGUIDE PORT 2-length in mm, for example VTST10-08-25 is a WR10 to WR08 transition with standard flanges on both ends with a length of 25 mm 2. There are variations in industry 'standard' flanges, when requesting for waveguides > 100 GHz advise required flange PIN and hole dimensions 3. For non-standard flanges; specify your requirements 31

Cryogenic Primary Noise Standard VivaTech s Cryogenic Noise Standard is a noise source with primary reference performance. Providing precision calibration of low noise components such as amplifiers, diode noise sources or receiver systems, it offers the ultimate in performance. The unique design provides coverage from 18 to 500 GHz in standard waveguide bands, incorporating replaceable waveguide assemblies. The standard is particularly suited to mm and sub-mm wave [THz] low noise measurement applications. Side entry design enables convenient connections to waveguide systems Vertical or horizontal waveguide orientation no mismatched bends or twists needed Low maintenance, compact temperature stabilization system no water cooling Interchangeable waveguide feed-horn assemblies provide mm to sub-mm wave [THz] coverage Automatic or manual LN2 filling-auto fill minimizes LN2 use and allows continuous operation Convenient, fully automated operation with integrated PC Real time noise temperature display at any frequency with full data logging Frequency (GHz) 18 26 26 40 90 140 220 275 275 325 325 400 400 500 Effective Noise Temperature (K) -1 83.27 82.98 83.45 83.95 85.20 81.06 79.27 76.82 72.45 71.31 69.60 Feed-horn Assembly Waveguide VTA-42-NS VTA-28-NS VTA-15-NS VTA-10-NS VTA-8-NS VTA-6-NS VTA-5-NS VTA-3.4FA-NS VTA-3.4FB-NS VTA-2.2FA-NS VTA-2.2FB-NS WR 42 WR 28 WR 3.4 WR 3.4 WR 2.2 WR 2.2 Typical Output Temperature Display 1. Typical average mid band noise temperature 2. How to make a request: Indicate the feed-horn assembly (s) required listed above; Specify manual or automatic liquid nitrogen filling. [Auto fill also adds a 35 litre LN2 dewar], send mail to: sales@vivatech.biz 32