FIRE STATION NO TH STREET NORTH ST. PETERSBURG, FL M-1 SCOPE OF WORK SYMBOL DESCRIPTION SYMBOL DESCRIPTION HVAC SYMBOL LEGEND

Similar documents
SECTION STRUCTURAL STEEL. A. PART A and DIVISION 1 of PART B are hereby made a part of this SECTION.

3 DATE ISSUE R# Forefront Dermatology. CONFLUENCE DESIGN GROUP #2 Daniel Drive O'Fallon, MO ph: St. Peters, Missouri 63376

SECTION METAL FABRICATIONS

PLAN CEILING FRAMING PLAN CEILING JOIST SCHEDULE. Tenant Improvements. UNLV Police Station Maryland Parkway.

A. Radius elbows with a construction radius of 1.5 the duct width are preferred to square elbows.

FLUOROPOLYMER COATED DUCT FOR CAUSTIC ENVIRONMENTS

Installation and Maintenance Manual IM 770-1

D. Thermally Sprayed Metallic Coating (Flame Spray): STD SPEC

1.1 RELATED DOCUMENTS

NORMAL WEIGHT CONCRETE TOTAL-LEWIS-DECK GYPSUM BOARD 2 OR 3-PLY COMPOSITE TOTALJOIST TOP CHORD CONNECTION

TECHNICAL CORRECTION October Process Industry Practices Structural. PIP STF05121 Fabrication and Installation of Anchor Bolts

Bidders and Others to Whom Bidding Documents have been issued by the Architect and/or CM.

DECKS. Stairway illumination Positive attachment of ledger Lateral load connection required board (R507.2) required (R ) (R311.7.

BUILDING PLANS. BUILDING INSPECTIONS DEPARTMENT

SECTION LOW PRESSURE DUCTWORK

GLOSSARY OF TERMS SECTION 8

SECTION STRUCTURAL STEEL FRAMING PART 1 - GENERAL 1.1 RELATED DOCUMENTS

SECTION BULLET- RESISTANT DOORS

B. Shop Drawings: Include elevations, door edge details, frame profiles, metal thicknesses, preparations for hardware, and other details.

.1 Comply with the General Conditions of the Contract, Supplementary General Conditions and the requirements of Division 1.

CSS Central Mount System

Installation and Maintenance Manual

RAIL PANEL AT TRANSITION SECTION PLAN - POST DETAIL PLAN - TUBE SPLICE. Colorado Department of Transportation. Staff Bridge Branch

A. Rough carpentry includes but is not limited to the following:

Collins Engineers Palmetto Islands County Park Boardwalk Repairs 03/28/2014 SECTION ROUGH CARPENTRY

University of Houston Master Construction Specifications Insert Project Name SECTION MECHANICAL SCOPE OF WORK PART 1 - GENERAL

PRESTON HEALTH SERVICES ARCHITECT S NO. 2700

B. Shop Drawings: Include elevations, door edge details, frame profiles, metal thicknesses, preparations for hardware, and other details.

SECTION SHEET METAL FLASHING AND TRIM

BUILDING PLANS. BUILDING DEPARTMENT

DIVISION 6 WOOD AND PLASTICS

INS A KSCR INSTALLATION INSTRUCTIONS STANDARD PROCEDURE. 1. Unpacking the KSCR Splicing the KSCR (If Required)...

Attachment of Residential Deck Ledger to Side of Metal Plate Connected Wood Truss Floor Ladder. Installation Instructions Revised 9/2/2016

SECTION CABLE TRAYS FOR COMMUNICATIONS SYSTEMS

INSTALLATION SHOP DRAWINGS FOR MINNEAPOLIS, MN

STEEL PIPE GUIDERAIL 01/01/

LOW PRESSURE STEEL DUCTWORK Mechanical Systems Insulation Outlets (HVAC) Testing and Balancing.

SECTION STEEL LIGHTING STANDARDS. 1. Electrical conduit and fittings; Section

EMMEGI ARCHITECTURAL FENCING MASTER SPECIFICATION SECTION METAL FENCING, GATES & RAILING SYSTEM PART 1 GENERAL

Series Sloped glazed Curtain wall. Installation Instructions

Attachment of Residential Deck Ledger to Metal Plate Connected Wood Truss Floor Systems Overview Revised 9/2/2016

3.1 General Provisions

The General Provisions of the Contract, including General, Supplementary and Special Conditions, apply to the work specified in this Section.

CSP PSYCHIATRIC SERVICES UNIT SECTION IDENTIFICATION FOR HVAC PIPING AND EQUIPMENT

CITY OF PITTSBURG ENGINEERING DEPARTMENT CONTRACT NO A WATER TREATEMENT PLANT CAPITAL IMPROVEMENTS PHASE 1A ADDENDUM #1 FENCE AND DITCH AUGUST

INS A KSR INSTALLATION INSTRUCTIONS STANDARD PROCEDURE. 1. Verify Curb Installation Required Installation Tools...

PART MATERIALS. Section Fencing Materials. Description

PIP STF05121 Anchor Fabrication and Installation Into Concrete

Connectors for Cold-Formed Steel Curtain-Wall Construction

(50 FT FT) MICHIGAN DEPARTMENT OF TRANSPORTATION 10-0" 7-6" 8-0" 6-0" Truss Depth. 3" sheets 5 & 6 of 10) DEPARTMENT DIRECTOR. Kirk T.

REINFORCEMENT DESIGN FOR METAL BUILDING SYSTEMS

2. All work and materials shall be in full accordance with Local and State ordinance and with any prevailing rules and regulations.

SECTION ROUGH CARPENTRY

SECTION EXPANSION FITTINGS AND LOOPS FOR HVAC PIPING

SECTION HOLLOW METAL DOORS AND FRAMES

SUBMITTAL REQUIREMENTS FOR COMMERCIAL BUILDING PROJECTS

Hang-TITE Rod Hanger Screws

3. Are component and cladding design pressures consistent with ASCE 7 for the wind speed and exposure category (ASCE 7 Fig. 6-3)?

1.1 SUMMARY. A. This Section includes the following: 1. Loose steel lintels. 2. Shelf angles. 3. Metal floor plate. 4. Pipe bollards.

American Safe Room. Explosion Resistant Blast Hatch with Integrated Riser

DHS-500 IMPACT SYSTEM INSTALLATION MANUAL

Section COUPLINGS AND COUPLING ADAPTERS. This Section covers couplings and coupling adapters for ductile iron and steel pipe.

Residential Room Addition / Remodel Submittal Requirement Checklist

6o ft (18.3 m) Southwest Windpower, Inc West Route 66 Flagstaff, Arizona USA Phone: Fax:

KOLO SHELTER Installation Instructions Parts List

Installation Instructions

ALUMINUM PIPE GUIDERAIL 01/01/

STANDARD SPECIFICATION FOR STEEL FRAMING FOR RAILROAD SHELTERS

*************************************************************************************************************

STRUCTURAL STEEL AND ALUMINUM PART 1 - GENERAL 1.01 SCOPE:

REQUEST FOR INFORMATION

XL MAX. Suspension System Data Center Ceiling Solutions. Assembly and Installation Instructions

APPENDIX FENCE GENERAL NOTES

SECTION MECHANICAL IDENTIFICATION

SWAY BRACE PIPE ATTACHMENT FIG. 010

SuperMount Series Installation instructions for SuperMount 46, 68 & 80 wall structures Bill Of Materials

Load Tables, Technical Data and Installation Instructions

APPLICATION FOR A BUILDING PERMIT

KO LO SH E LT E R. High Capacity and Flexibility

STRUCTURAL ATTACHMENTS

Typical Deck Details

Windows Installed into Walls with Polyiso and Wood Framing. Installation Instructions Standard Method Revised 10/24/2016

SECTION THERAPEUTIC POOL ACCESSORIES

Typical Deck Details

Single-Family Dwelling Submittal Requirements

SECTION CONCRETE REINFORCEMENT FOR STEAM UTILITY DISTRIBUTION

GENERAL ISOMETRIC LAYOUT


Featuring TJ Rim Board and TimberStrand LSL

Sheet Metal Worker Level 2

KS SERIES - VERTICAL INSTALLATION

Technical Development Program

5/16" Flange nut. Bolt Keeper Plate (8" Sq. SYS.) (3) 1/2" x 3" Hex head connector zinc plated bolt w/ washers and nut. Anchor 3" sq. 7 Ga.

GrowSpan Series 500 Roll-Up Ends

City of Thousand Oaks

TYPE J (20 FT - 40 FT) MICHIGAN DEPARTMENT OF TRANSPORTATION 10-0" 7-6" NOTE: sheet 5 & 6 of 10) DEPARTMENT DIRECTOR. Kirk T.

2016 AASHTO BRIDGE COMMITTEE AGENDA ITEM: 24 (REVISION 1) SUBJECT: LRFD Bridge Design Specifications: Section 6, Various Articles (2)

TOLL FREE:(888) FAX:(941) ASSEMBLY of ProTEC CONCRETE STRUCTURAL INSULATED PANEL

Beam & Header Technical Guide. LP SolidStart LVL. 2900F b -2.0E. U.S. Technical Guide U.S. TECHNICAL GUIDE

Fastener Schedule. a, b, c. FASTENER Roof 3-8d (2 1 / ) / ) 3-10d. 3-10d ( ) 3-16d box nails. (3 1 2 toe nails on one side

Transcription:

HVAC SYMBOL LEGEND HVAC PIPING AND VALVES LEGEND HVAC GENERAL NOTES SCOPE OF WORK SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION PHASING OF WORK HVAC ABBREVIATIONS ABBREVIATION DESCRIPTION ABBREVIATION DESCRIPTION ABBREVIATION DESCRIPTION ABBREVIATION DESCRIPTION MISCELLANEOUS SYMBOLS NOTE: SOME SYMBOLS AND ABBREVIATIONS SHOWN MAY NOT PERTAIN TO THIS PROJECT. Drawn JWY Designed JWY DATE: SCALE: NOT TO SCALE DRAWING No. 11065-02 M-1

GENERAL NOTES: KEYED NOTES: MECHANICAL DEMOLITION PLAN NORTH SCALE : 1/4" = 1'-0" Drawn JWY Designed JWY DATE: SCALE: 1/4" = 1'-0" DRAWING No. 11065-03 M-2

GENERAL NOTES: KEYED NOTES: MECHANICAL RENOVATION PLAN NORTH SCALE : 1/4" = 1'-0" Drawn JWY Designed JWY DATE: SCALE: 1/4" = 1'-0" DRAWING No. 11065-04 M-3

ROOF MOUNTED PIPE SUPPORT DETAIL GENERAL NOTES: KEYED NOTES: MECHANICAL ROOF RENOVATION PLAN NORTH SCALE : 1/4" = 1'-0" Drawn JWY Designed JWY DATE: SCALE: 1/4" = 1'-0" DRAWING No. 11065-05 M-4

FIBERGLASS BLANKET DUCT INSULATION DETAIL ROOFTOP UNIT CURB TIE-DOWN DETAIL TURNING VANES DETAIL CONDENSATE DRAIN TRAP DETAIL DUCT RUNOUT TO DIFFUSER DETAIL DUCTWORK SUPPORT DETAIL DUCTWORK FITTINGS DETAIL Drawn JWY Designed JWY DATE: SCALE: NOT TO SCALE DRAWING No. 11065-06 M-5

PACKAGED DX APPLIED ROOFTOP UNIT SCHEDULE AIR DEVICE SCHEDULE RTU / EXHAUST FAN INTERLOCK SCHEDULE ASHRAE 62.1-2007 OUTSIDE AIR CALCULATION COMMERCIAL Standard 8-wire twisted net cable Twisted Pair, 22 AWG. Typical Twisted Pair, 18 AWG. Typical Standard 8-wire twisted net cable RTU CONTROLS Drawn JWY Designed JWY DATE: SCALE: NOT TO SCALE DRAWING No. 11065-07 M-6

ELECTRICAL SYMBOL LEGEND ELECTRICAL GENERAL NOTES: ABBREVIATIONS: NATIONAL ELECTRIC CODE NOTES: ELECTRICAL SUBMITTAL NOTES: RHM RHM Drawn RHM Designed RHM DATE: SCALE: NO SCALE DRAWING No. 11065-08 E-1

POWER DEMO NOTES: NORTH ELECTRICAL DEMOLITION PLAN SCALE : 1/4" = 1'-0" Drawn RHM Designed RHM DATE: SCALE: 1/4" = 1'-0" DRAWING No. 11065-09 E-2

POWER RENO NOTES: ELECTRICAL ROOF RENOVATION PLAN NORTH SCALE : 1/4" = 1'-0" Drawn RHM Designed RHM DATE: SCALE: 1/4" = 1'-0" DRAWING No. 11065-10 E-3

LOAD SUMMARY RISER RENOVATION NOTES: Drawn RHM Designed RHM BY DATE DATE: ENGINEERING and CAPITAL SCALE: NO SCALE DRAWING No. 11065-11 E-4

DETAIL NOTES: RTU-1 Fed from Panel P1 AC UNIT NAMEPLATE DETAIL TYPICAL DUCT SMOKE DETECTOR WIRING DETAIL ROOFTOP UNIT ELECTRICAL SCHEME Drawn RHM Designed RHM BY DATE DATE: ENGINEERING and CAPITAL SCALE: NO SCALE DRAWING No. 11065-12 E-5

STRUCTURAL SPECIFICATIONS: STRUCTURAL SPECIFICATIONS: 1. CONTRACTOR IS RESPONSIBLE TO VERIFY AND COORDINATE ALL DIMENSIONS AND DETAILS BEFORE PROCEEDING WITH WORK. ANY DISCREPANCIES MUST BE IMMEDIATELY BROUGHT TO THE ATTENTION OF THE ENGINEER. THE CONTRACTOR NOTE: PROVIDE JOIST REINFORCING IN ACCORDANCE WITH THIS DETAIL FOR ALL CONCENTRATED LOADS IN EXCESS OF 150 POUNDS THAT ARE NOT SHOWN ON THE ROOF FRAMING PLAN. C.L. OF JOIST COPE HORIZONTAL LEG EXISTING JOIST CHORD IS ALSO SOLELY RESPONSIBLE FOR INITIATING, MAINTAINING AND SUPERVISING ALL SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THE WORK. NEITHER THE CITY NOR THE DESIGN PROFESSIONALS ARE RESPONSIBLE FOR THE MEANS AND METHODS OF CONSTRUCTION OR FOR RELATED SAFETY PRECAUTIONS AND PROGRAMS. 2. TYPICAL DETAILS AND WALL SECTIONS SHOWN APPLY TO ALL SIMILAR SECTIONS AND CONDITIONS UNLESS NOTED OTHERWISE. 3. CONTRACTOR MUST FULLY BRACE AND PROTECT ALL WORK IN PROGRESS UNTIL THE STRUCTURE IS COMPLETED. 4. THE STRUCTURE AND ALL APPLICABLE COMPONENTS FOR THIS PROJECT HAVE BEEN DESIGNED IN ACCORDANCE WITH APPROPRIATE PROVISIONS OF EACH OF THE FOLLOWING: 4.1. THE 5TH EDITION (2014) FLORIDA BUILDING CODE. 4.2. AISC MANUAL OF STEEL CONSTRUCTION, LATEST EDITION. 5. THE FOLLOWING STRUCTURAL CONSTRUCTION DOCUMENTS MUST BE USED IN CONJUNCTION WITH ALL APPLICABLE SPECIFICATIONS AND THE CONSTRUCTION DOCUMENTS. IF THERE IS A DISCREPANCY BETWEEN DOCUMENTS, IT IS THE CONCENTRATED LOAD, SEE NOTE 3" MINIMUM TYPICAL EACH END EACH ANGLE 1/8" 1-1/2" 1/8" 1-1/2" CONTRACTOR TO PROVIDE AND FIELD INSTALL L2" x 2" x 3/16" STRUT EACH SIDE OF JOIST AT ALL LOCATIONS WHERE CONCENTRATED LOAD DOES NOT OCCUR WITHIN 3" OF A PANEL POINT. INSTALL ANGLE WITH ONE END AT LOCATION OF LOAD AND OTHER END AT A PANEL POINT ON THE OPPOSITE CHORD, TYPICAL. 3" MINIMUM CONCENTRATED LOAD, SEE NOTE LENGTH A A C C B WIDTH B 1/8" 1/8" FIELD FABRICATE FRAME FROM L4" x 4" x 3/8" C.L. OF JOIST TYP PRE-ENG / PRE-FAB ADJUSTABLE 16 GA ROOF CURB. CONNECTION OF CURB TO STRUCTURE IS THE RESPONSIBILITY OF THE MECHANICAL ENGINEER 6" O/C AROUND PERIMETER OF OPENINGS 3/16" 1/8" 1/8" SECTION A-A NOT TO SCALE PRE-ENG / PRE-FAB ADJUSTABLE 16 GA ROOF CURB. CONNECTION OF CURB TO STRUCTURE IS THE RESPONSIBILITY OF THE MECHANICAL ENGINEER CONTRACTOR'S RESPONSIBILITY TO NOTIFY THE ENGINEER PRIOR TO PERFORMING ANY AND ALL CONSTRUCTION. IN CASE OF CONFLICT THE MOST STRINGENT CONDITION MUST ALWAYS APPLY. 6. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO FIELD VERIFY ALL DIMENSIONS AND COORDINATE WITH STRUCTURAL CONSTRUCTION DOCUMENTS AND WITH ANY AND ALL APPLICABLE EQUIPMENT MANUFACTURER'S (I.E. WINDOW, DOOR, AIR HANDLER, ETC.). IF THERE ARE ANY POTENTIAL CONFLICTS THE CONTRACTOR IS REQUIRED TO REQUEST AND RECEIVE A DIRECTIVE FROM THE ENGINEER PRIOR TO D3 JOIST REINFORCEMENT DETAIL NOT TO SCALE Joist Reinforcement Detail SCALE: 3/4" = 1 0" PLAN VIEW NOT TO SCALE SECTION B-B NOT TO SCALE RTU SUPPORT FRAMES FOR NEW ROOF PENETRATIONS IN EXISTING ROOF NOT TO SCALE SECTION C-C NOT TO SCALE 6" O/C AROUND PERIMETER OF OPENINGS PERFORMING WORK. 7. IF THERE ARE ANY DIMENSION'S NOT SHOWN ON THE STRUCTURAL CONSTRUCTION DOCUMENTS REQUIRED FOR CONSTRUCTION THE CONTRACTOR MAY REFER TO TYPICAL RTU CURB TO SUPPORT ANGLE FRAME DETAIL TYPICAL RTU CURB TO SUPPORT ANGLE FRAME DETAIL TYPICAL RTU CURB TO SUPPORT ANGLE FRAME DETAIL CONTACT THE ENGINEER FOR ADDITIONAL INFORMATION. STRUCTURAL STEEL: 1. ALL STRUCTURAL STEEL ELEMENTS SHALL BE HOT-DIPPED GALVANIZED AND SHALL BE FABRICATED AND ERECTED IN ACCORDANCE WITH THE LATEST A.I.S.C. SPECIFICATIONS. 2. STRUCTURAL STEEL ELEMENTS SHALL CONFORM TO THESE SPECIFICATIONS: ANCHOR BOLTS ASTM F1554 FRAMING BOLTS ASTM A325 OR A490 SHAPES (C,L,PL,T) ASTM A36 SHEAR STUDS ASTM A108 STEEL PIPE (HSS) ASTM A500 (42 KSI) STRUCTURAL TUBE (HSS) ASTM A500 (46 KSI) WELDING ELECTRODES E70XX WIDE FLANGE (WF) ASTM A992 (50 KSI) 3. SHOP CONNECTIONS MAY BE WELDED OR FASTENED BY HIGH STRENGTH BOLTS. ALL CONNECTIONS SHALL CONFORM TO STANDARD CONNECTION DETAILS ON THE PLANS, UNLESS EXPLICIT APPROVAL FROM THE ENGINEER HAS BEEN OBTAINED. ALL CONNECTIONS TO BE DOUBLE ANGLE FRAMED BEAM CONNECTION PER A.I.S.C. UNLESS NOTED OTHERWISE. 2" MAX 12" O/C MAX 12" O/C MAX 12" O/C 2" MAX 12" O/C 2" MAX 12" O/C MAX 12" O/C MAX 12" O/C TYPICAL RTU UNIT MAX WEIGHT = 1,500LBS MAX HEIGHT = 6'-0" COORDINATE DIMENSIONS OF UNIT WITH MECH. ENG. 2" LENGTH & WIDTH ANGLE FRAME TO MATCH LENGTH & WIDTH OF RTU LOCATION OF 1/4"Ø x 2 1/2" HILTI SELF-DRILLING SCREWS, THROUGH METAL DECK INTO STEEL ANGLE, TYPICAL. STEEL ROOF JOIST OR BEAM, SEE PLAN FOR SIZE AND LOCATION ATTACH CURB TO STEEL ANGLES WITH 1/4" x 2.5" HILTI SELF DRILLING SCREWS @ 12" O/C AROUND PERIMETER. FASTENERS MUST START WITH 2" OF THE ENDS OF ALL SIDE OF THE CURB. TYPICAL RTU UNIT MAX WEIGHT = 1,500LBS MAX HEIGHT = 6'-0" PROVIDE JOIST REINF. AT CONCENTRATED LOAD LOCATIONS PER "JOIST REINFORCEMENT DETAIL", TYPICAL. GASKET, REFER TO MECHANICAL DRAWINGS. PRE-ENG / PRE-FAB ADJUSTABLE 16 GA ROOF CURB. G.C. MUST PROVIDE 2x BLOCKING UNDER DECK AT LOCATION OF CURB, WHERE APPLICABLE. ATTACH CURB TO STEEL ANGLES WITH 1/4" x 2.5" HILTI SELF DRILLING SCREWS @ 12" O/C AROUND PERIMETER. FASTENERS MUST START WITH 2" OF THE ENDS OF ALL SIDE OF THE CURB. TYPICAL RTU UNIT MAX WEIGHT = 1,500LBS MAX HEIGHT = 6'-0" STEEL ANGLE FRAME, SEE TYPICAL DETAIL. REQUIRED AT ALL RTU LOCATIONS. GASKET, REFER TO MECHANICAL DRAWINGS. PRE-ENG / PRE-FAB ADJUSTABLE 16 GA ROOF CURB. DECK MUST BE WELDED TO ANGLE FRAME 36-7 (EACH FLUTE TO ANGLE) 4. DESIGN CONNECTIONS FOR THE MAXIMUM SHEAR (V IN KIPS) LISTED IN THE TABLES FOR "ALLOWABLE UNIFORM LOADS IN KIPS FOR BEAMS LATERALLY SUPPORTED", AT THE BOTTOM OF EACH PAGE IN THE "PROPERTIES AND REACTION VALUES", OF PART TWO OF THE LATEST EDITION OF THE A.I.S.C. "MANUAL OF STEEL CONSTRUCTION". 5. ALL BOLTS SHALL BE A MINIMUM OF 3/4" IN DIAMETER, AND BE PROVIDED WITH CURB ATTACHMENT - PLAN VIEW NOTES: 1. CONTRACTOR IS TO PROVIDE FRAME UNDER ALL RTU'S 2. CONTRACTOR MUST CONTACT THE ENGINEER IF UNIT EXCEEDS MAXIMUM HEIGHT AND/OR WEIGHT. CURB ATTACHMENT PARALLEL TO DECK SPAN. NOTES: 1. CONTRACTOR IS TO PROVIDE FRAME UNDER ALL RTUs. 2. CONTRACTOR MUST CONTACT THE ENGINEER IF UNIT EXCEEDS MAXIMUM HEIGHT AND/OR WEIGHT. CURB ATTACHMENT PERPINDICULAR TO DECK SPAN. NOTES: 1. CONTRACTOR IS TO PROVIDE FRAME UNDER ALL RTUs. 2. CONTRACTOR MUST CONTACT THE ENGINEER IF UNIT EXCEEDS MAXIMUM HEIGHT AND/OR WEIGHT. HARDENED WASHERS UNDER THE TURNED ELEMENT (BOLT HEAD OR NUT). 6. ALL CONNECTIONS PERFORMED IN THE FIELD SHALL BE MADE WITH HIGH STRENGTH BOLTS, SLIP-CRITICAL (FRICTION) TYPE. 7. INSTALLATION AND TIGHTENING OF ALL HIGH STRENGTH BOLTS MUST CONFORM TO "SPECIFICATION FOR STRUCTURAL JOINTS USING ASTM A325 OR A490 BOLTS". 8. ALL WELDING OPERATIONS MUST CONFORM TO THE AMERICAN WELDING SOCIETY CODE, ANS01.1, AND ALL WELDS SHALL BE PERFORMED USING E70XX, U.N.O. WELDS ARE TO BE EQUAL IN STRENGTH TO SIMILAR BOLTED CONNECTIONS. 9. WELDING STRUCTURAL STEEL MEMBERS TO EMBED PLATES IN CONCRETE MUST BE PERFORMED WITH EXTREME CARE. OVERHEATING THE EMBED PLATE DURING THE WELDING PROCESS WILL CAUSE SEVERE DEGRADATION OF THE PERFORMANCE OF THE CONNECTION. WELD IN SHORT, SINGLE PASSES (NO MORE THAN 6" OF LENGTH FOR 1/4" THICK WELD), AND ALLOW AMPLE COOLING-OFF TIME BETWEEN EACH WELD. THICKER WELDS SHOULD BE PERFORMED IN MULTIPLE PASSES, WITH A COOLING-OFF PERIOD FOR EACH PASS. 10. GALVANIZE ALL STEEL MEMBERS EXPOSED TO WEATHER (SUCH AS LINTELS, DOOR JAMBS, ETC.). 11. CUTS, HOLES, COPINGS, AND ALL OTHER MODIFICATIONS REQUIRED TO BE MADE FOR THE WORK OF OTHER TRADES SHALL BE SHOWN IN THE STRUCTURAL STEEL SHOP DRAWINGS, AND SHALL BE PERFORMED ONLY BY THE SHOP ISSUING SAID DRAWINGS, OR OTHER FACILITY APPROVED BY THE ENGINEER TO PERFORM SAID WORK. HOLES IN STRUCTURAL ELEMENTS SHALL BE REINFORCED AS REQUIRED BY THE ENGINEER. 12. CUTTING, BURNING OF HOLES, OR OTHER MODIFICATIONS TO STEEL MEMBERS IN THE FIELD IS NOT PERMITTED WITHOUT THE EXPLICIT APPROVAL OF THE ENGINEER. 13. STEEL MEMBERS REQUIRED BY OTHER TRADES TO SUPPORT THEIR EQUIPMENT, WHICH ARE NOT ALREADY PRESENT ON THE STRUCTURAL DRAWINGS, SHALL BE PROVIDED BY THE TRADE REQUIRING SUCH WORK. 14. ANY PROPOSED REVISIONS CONTEMPLATED BY THE CONTRACTOR TO THESE STRUCTURAL DETAILS OR ANY ALTERNATIVE DESIGN(S) FOR MODIFYING THE EXISTING STRUCTURAL ROOF SUPPORT SYSTEM FOR ENABLING SUPPORT AND INSTALLATION OF NEW ROOF MOUNTED EQUIPMENT SHALL BE SUBMITTED AS SHOP DRAWINGS AND SHALL BE PREPARED, DESIGNED, AND SIGNED AND SEALED BY A FLORIDA LICENSED PROFESSIONAL ENGINEER SHOWING ALL DETAILS AND ALL DESIGN LOAD CALCULATIONS. FULLONE STRUCTURAL GROUP 9600 KOGER BOULEVARD, SUITE #227 ST. PETERSBURG, FLORIDA 33702 PHONE: (727) 577-2222 FAX: (727) 577-2221 EB: # 28152 PROJECT#: 1074-001 Drawn Designed Fullone Structural Group EB: # 28152 Joseph P. Fullone, P.E. FL. PE: # 67563 Signature Date DATE: STRUCTURAL SPECIFICATIONS & SCALE: 3/4" = 1'-0" TYPICAL DETAILS DRAWING No. 11065-13 S-1

EXISTING J-3 EXISTING J-3 EXISTING J-3 EXISTING J-3 EXISTING J-3 EXISTING A-1 EXISTING J-2 EXISTING J-2 EXISTING J-2 EXISTING J-2 EXISTING J-2 EXISTING J-2 EXISTING J-1 EXISTING J-1 EXISTING J-1 EXISTING J-1 EXISTING J-1 EXISTING J-1 RTU-1 MAX WEIGHT= 1,400 LBS NEW ROOF TOP UNIT (RTU) SEE MECHANICAL FOR SIZE AND WEIGHT, SEE TYPICAL DETAILS FOR CONN. OF NEW TO EXISTING ROOF. CENTER UNIT OVER EXISTING MASONRY WALL, AS SHOWN. NEW ROOF TOP UNIT (RTU) SEE MECHANICAL FOR SIZE AND WEIGHT, SEE TYPICAL DETAILS FOR CONN. OF NEW TO EXISTING ROOF. CENTER UNIT OVER EXISTING MASONRY WALL, AS SHOWN. RTU-3 MAX WEIGHT= 1,300 LBS RTU-2 MAX WEIGHT= 1,400 LBS EXISTING J-6 EXISTING J-5 EXISTING J-4 EXISTING J-6 EXISTING J-5 EXISTING J-4 EXISTING J-5 EXISTING J-4 EXISTING J-6 FULLONE STRUCTURAL GROUP 9600 KOGER BOULEVARD, SUITE #227 ST. PETERSBURG, FLORIDA 33702 PHONE: (727) 577-2222 FAX: (727) 577-2221 EB: # 28152 PROJECT#: 1074-001 Drawn Designed Fullone Structural Group EB: # 28152 Joseph P. Fullone, P.E. FL. PE: # 67563 Signature Date DATE: NEW RTU LOCATION / SCALE: 1/4" = 1'-0" EXISTING ROOF FRAMING PLAN DRAWING No. 11065-14 S-2