MBS AG. KBR 18 Split-core current transformer. Further information about our new split-core current transformer KBR 18: Dimensions:

Similar documents
Measuring current transformer for universal measuring devices

Transducing electrical quantities Iskra MIS d.d. Measuring Transducers. Features

Current / residual current and voltage transformers. Current / residual current and voltage transformers

Measuring current transformers of the W, W series

CYHCS-RC2S Split Core Hall Effect DC Current Sensor

Current Transducer CTSR 1-P = 1A

Operating Instruction

CONTA-ELECTRONICS. Converter Units

Coupling Relays and Converters

Switching power supplies CP range, Linear power supplies CP-L range. Content

DATA SHEET Selectable AC transducer TAS-311DG

DC Current Sensor CYCT04-xnL20

ProLine P Precise Temperature Measurement at High Voltage Potentials up to 6.6 kv

Input Modules for TESLA Power System Recorders

Medium-voltage transfomers

Connection. Input EEx ia IIC. Sense. Fine tuning adjustment. Fine tuning amplifying. Amplifying. Adjustment. Output. Composition

DC Current Transducers

SIMEAS-T. Operating Instructions Transducer without auxiliary power. 7KG6111 and 7KG6101. Operating Instructions

RISH Ducer E13 3 channel transducer for AC current and voltage

For Immediate Delivery call KMParts.com at (866)

MCR-VAC-UI-0-DC. Voltage transducer for AC voltages. INTERFACE Data sheet _en_02. 1 Description

Loop-Powered Isolators for Standard Signals

SINEAX TV 808, 2 channels Isolating Amplifier Unipolar/Bipolar

Theta 20A / 20V. Technical Data Sheet. Special Features

RISH Ducer TV 808, 2 channels Isolating amplifier unipolar / bipolar

Installation / Monitoring Technique

V P N. Voltage transducer DVM 2000-B = 2000 V

I P. /dt. di p V S+ Applications. Standards. 1) IEC ed1.0: 2007; IEC : ed1.0: 2012

IsoTrans 41. The load capability of the 20 ma source is limited and therefore requires efficient use of the load voltage.

MCR-SL-CUC Universal current transducer. Data sheet _en_05. 1 Description

DSSIU-6-1U. Dedicated 6-channel system interface unit for ultra-stable, high precision fluxgate technology DS series current transducers.

POWER TRANSDUCERS ACTIVE AND REACTIVE SERIES: T-W WATT T-V VAR

Summation current transformers, type KSU/SUSK

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary circuit and the secondary circuit.

XR1 Rotor Earth Fault Relay. (May 2007) Manual XR1 (Revision New)

TPS TRANSDUCER POWER SUPPLY & LEM IT CURRNET TRANSDUCER

W DATA SHEET Current Transformer 40 x 10, A

400,440Vac Vdc V, A, W, VA, var, Hz, V, Avg. A cos phi, sin phi and phi measurement kwh, kvarh (via Pulse Output)

TVA 080 / 100 / 120 / 180 / 200 / 220 Isolation amplifier active

Technical features table for miniature circuit-breakers SH 200 Series

COMPACT LED DRIVERS. ComfortLine Selectable Current (LEDset) ComfortLine SELECTABLE CURRENT LEDset ,

Isolators A3/1. Temperature Transmitter Field Circuit Non-Ex i Series

T40FH. Torque flange. Special features. Data sheet

Transformers, Power Supply Units and Socket Outlets

"Modular" versions designed for application-specific functions LCD with 4 lines of 18 characters and configurable backlighting

Theta Hz. Technical Data Sheet. Special Features

XI1-I Time overcurrent relay. (Januar 2007) Manual XI1-I (Revision New)

Measuring Transducer MT4xx series Programmable AC Current Transducer MT418

TRIO-PS/1AC/24DC/ 5. Extract from the online catalog. Order No.:

RI-D440. Three Phase easywire Multifunction DIN Rail Energy Meter. Telephone : +44 (0) Displayed Parameters

Custom "Compact" range with display CD20 Custom Part number

Installation and Operating Manual

QUINT-PS-24DC/24DC/10

Powered by technology...driven by service CURRENT TRANSFORMERS. Multifunction Meters. Transducers & Isolators. Temperature Controllers

For non-electrical quantities

n True RMS measurement n Fully onsite programmable input voltage range (for CIP-V)

Universal measuring transducer

MODEL AT-10 ANALOG TRANSMITTER

02/11/2015

Theta 60R. Technical Data Sheet. Special Features. Fig. 2 Theta R, 2 channel version, in housing S17 hole mounting brackets pulled out.

MCTS II Multi Channel Current Transducer System. Installation Manual

SINEAX I 503 / SINEAX U 504 Transducer for AC current or AC voltage

Isolators A3/1.

PCB relay for DC voltage, polarized, monostable or bistable

Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800)

SINEAX V 624 Programmable Temperature Transmitter for RTD and TC inputs

Series P. Applications

Fluke 83V and 87V Digital Multimeters

SPECIFICATION Item no.: T60404-N4646-X762

SPECIFICATION Item no.: T60404-N4646-X764

I P. /dt. di p V S Applications. Standards 1) IEC : 2007; IEC : ) IEC : 2016; IEC : 2017

DEIF A/S. TAS-311DG Selectable AC transducer J (UK) Installation and start up instructions

LED Driver Compact fixed output

Analog signal converters CC-E I/I

METRATESTER 5+ Tester for DIN VDE /6.15

PHASED OUT. LED Driver Linear / area fixed output. Driver LCI 35W 350mA 900mA TOP lp TOP series

PHASED OUT. LED Driver Linear / area fixed output. Driver LCI 20W 150mA 400mA TOP lp TOP series. Product description

SINEAX TV 808, 1 channel Isolating Amplifier unipolar/bipolar

02/11/2015

DATASHEET - ETR4-70-A. Delivery program. Timing relay, 2W, 0.05s-100h, multi-function, VAC/DC, potentiometer connection

= 1000 V. Voltage transducer DVC 1000-P V P N

PHASED OUT. LED Driver Compact fixed output. Driver LCI 20W 350mA 900mA TOP C TOP series

10/2 Product overview. 10/3 4AC3 0, 4AC3 1 bell transformers. 10/5 4AC AC3 6 transformers for permanent loads. 10/8 4AC2 4 power supply units

E-STOP relays, safety gate monitors

Passive Current Transducers for Sinusoidal Alternate Currents From A/0...5 A MCR-SLP-1/5-UI-0(-SW)

PQ-Box 100 Network Analyzer for Low-, Medium- and High-Voltage Networks

PHASED OUT. LED Driver Compact fixed output. Driver LCI 10W 150mA 400mA TOP C TOP series. Product description

XUA1 AC Voltage and phase balance relay. (August 1996) Manual XUA1 (Revision New)

Testers: / Ohmmeters Insulation Measuring Instruments. n Compact and rugged for service calls and laboratory use. Scope of delivery:

T 1000 PLUS Secondary Injection Relay Test Set

Current clamps for AC current

DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters

For the electronic measurement of voltage: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

SPECIFICATION Item no.: T60404-N4646-X663

T 1000 PLUS. Secondary Injection Relay Test Set. Designed for testing relays and transducers

2/2 way Proportional Valve (motordriven)

SPECIFICATION Item no.: T60404-N4646-X651

E-STOP relays, safety gate monitors

SPECIFICATION Item no.: T60404-N4646-X662

20 General technical data XI/ON

Transcription:

KBR 18 Split-core current transformer Dimensions: Round conductor: 18 mm Transformer width: 41.6 mm Transformer height: 64.5 mm Transformer depth incl. fixing clasps: 67.3 mm General technical specifications: Thermal nominal continuous rated current I cth : 1.2 x I N Thermal nominal short-time current I th : 60 x I N, 1 Sek. Maximum operating voltage U m : 0.72 kv Isolation test voltage: 3 kv, U eff, 50 Hz, 1 min. Rated frequency: 50 Hz Isolation class: E Applicable technical standards: DIN EN 60044/1 VDE 0414 Teil 1 Further information about our new split-core current transformer KBR 18: Split-core current transformers are mainly used for an easy fitment and subsequent assembly into an already existing installation, without separating the primary conductor. The compact split-core current transformer KBR 18 has been developed to have easy access in already existing installations. Due to the click -system and the fixing-clasps even a one-hand mounting is possible. The delivery follows with 2.5 m connection cable 2x0.75 mm² (color coded; S1 = brown; S2 = blue). Other lengths of the connection cables are possible on request. For the use as a current sensor the KBR 18 is optionally deliverable with a voltage output of 0 333 mv (Min. burden resistance 1 kω). Operating temperature: -5 C < T < +50 C Storage temperature: -25 C < T < +70 C Page 10

Order list Output 1 A AC 0 333 mv AC Accuracy class Accuracy class Primary current Burden Primary current 3FS5 1FS5 1 [ VA ] Art.-no. Art.-no. Art.-no. 50 1 18-0001 50 18-1001 75 1 18-0006 75 18-1006 100 1.25 18-0011 100 18-1011 125 1.5 18-0016 125 18-1016 150 2 18-0021 150 18-1021 200 1 18-0027 3 18-0026 200 181026 250 1.5 18-0032 4 18-0031 250 18-1031 Page 11

KBR 32 Split-core current transformer Dimensions: Round conductor: 32.5 mm Transformer width: 59.2 mm Transformer height: 96.4 mm Transformer depth incl. fixing clasps: 89.2 mm General technical specifications: Thermal nominal continuous rated current I cth : 1.2 x I N Thermal nominal short-time current I th : 60 x I N, 1 Sek. Maximum operating voltage U m : 0.72 kv Isolation test voltage: 3 kv, U eff, 50 Hz, 1 min. Rated frequency: 50 Hz Isolation class: E Applicable technical standards: DIN EN 60044/1 VDE 0414 Teil 1 Further information about our new split-core current transformer KBR 32: Split-core current transformers are mainly used for an easy fitment and subsequent assembly into an already existing installation, without separating the primary conductor. The compact split-core current transformer KBR 32 has been developed to have easy access in already existing installations. Due to the click -system and the fixing-clasps even a one-hand mounting is possible. The KBR 32 with secondary 1A will be delivered with 2.5 m connection cable 2x0.75 mm² (color coded; S1 = brown; S2 = blue). Other lengths of the connection cables are possible on request. The secondary 5A version will be delivered with 0.5m connection cable 2x1.5 mm². For the use as a current sensor the KBR 32 is optionally deliverable with a voltage output of 0 333 mv (min. burden resistance 1 kω). Moreover the KBR 32 is deliverable as a measuring transducer with a measuring output of 4 20 ma DC. Operating temperature: -5 C < T < +50 C Storage temperature: -25 C < T < +70 C Page 12

Order list Secondary current 5A 1A Output 0 333 mv 4 20 ma signal AC DC Primarycurrent current class class Burden Accuracy class Accuracy class Primary- Accuracy Accuracy [ VA ] 3FS5 1FS5 3FS5 1FS5 1 1 Art.-no. Art.-no. Art.-no. Art.-no. Art.-no. Art.-no. 100 1.5 32-5011 2.5 32-0011 100 32-1011 32-2011 125 2.5 32-5016 3 32-0016 125 32-1016 32-2016 150 3 32-5021 32-0021 150 32-1021 32-2021 200 3 32-5026 5 32-0026 200 32-1026 32-2026 250 3 32-5031 5 32-0031 250 32-1031 32-2031 300 2.5 32-5035 5 32-0035 300 32-1034 32-2034 400 5 32-5037 32-0037 400 32-1036 32-2036 500 5 32-5039 32-0039 500 32-1038 32-2038 600 5 32-5041 32-0041 600 32-1040 32-2040 Technical characteristics for the KBR with output signal 4 20 ma: 2-wire connection, auxiliary power via output circuit Auxiliary power: 24 V DC ± 15 %, P V = max. 1 VA Load-independent DC current: Live-zero, 4 20 ma External resistance: max. 300 Ω Current limit under overload: < 30 ma Residual ripple of the output current: 1 % p.p. Response time: < 300 ms Wiring diagram of the KBR 32 (4 20 ma): Page 13

KBR 44 Split-core current transformer Dimensions: Round conductor: 44 mm Transformer width: 72.2 mm Transformer height: 120.6 mm Transformer depth incl. fixing clasps: 98.1 mm General technical specifications: Thermal nominal continuous rated current I cth : 1.2 x I N Thermal nominal short-time current I th : 60 x I N, 1 sec. Maximum operating voltage U m : 0.72 kv Isolation test voltage: 3 kv, U eff, 50 Hz, 1 min. Rated frequency: 50 Hz Isolation class: E Applicable technical standards: DIN EN 60044/1 VDE 0414 Teil 1 Further information about our new split-core current transformer KBR 44: Split-core current transformers are mainly used for an easy fitment and subsequent assembly into an already existing installation, without separating the primary conductor. The compact split-core current transformer KBR 44 has been developed to have easy access in already existing installations. Due to the click -system and the fixing-clasps even a one-hand mounting is possible. The KBR 44 with secondary 1A will be delivered with 2.5 m connection cable 2x0.75 mm² (color coded; S1 = brown; S2 = blue). Other lengths of the connection cables are possible on request. The secondary 5A version will be delivered with 0.5m connection cable 2x1.5 mm². For the use as a current sensor the KBR 44 is optionally deliverable with a voltage output of 0 333 mv (min. burden resistance 1 kω). Moreover the KBR 44 is deliverable as a measuring transducer with a measuring output of 4 20 ma DC. Operating temperature: -5 C < T < +50 C Storage temperature: -25 C < T < +70 C Page 14

Order list Secondary current Primary current Burden [ VA ] 5A 1A Output signal 0 333 mv AC 4 20 ma DC Accuracy class Accuracy class Primary Accuracy class Accuracy class 1FS5 1FS5 current 1 1 Best.-Nr. Best.-Nr. Best.-Nr. Best.-Nr. 250 1.5 44-5001 2.5 44-0001 250 44-1001 44-2001 300 2.5 44-5006 44-0006 300 44-1006 44-2006 400 5 44-5011 44-0011 400 44-1011 44-2011 500 5 44-5016 44-0016 500 44-1016 44-2016 600 5 44-5021 44-0021 600 44-1021 44-2021 750 5 44-5026 44-0026 750 44-1026 44-2026 800 5 44-5031 44-0031 800 44-1031 44-2031 1000 5 44-5036 44-0036 1000 44-1036 44-2036 Technical characteristics for the KBR with output signal 4 20 ma: 2-wire connection, auxiliary power via output circuit Auxiliary power: 24 V DC ± 15 %, P V = max. 1 VA Load-independent DC current: Live-zero, 4 20 ma External resistance: max. 300 Ω Current limit under overload: < 30 ma Residual ripple of the output current: 1 % p.p. Response time: < 300 ms Wiring diagram of the KBR 44 (4 20 ma): Page 15