DX-M CR SOLUTION DX-M. The next generation CR System for Digital Mammography and General Radiography.

Similar documents
Why Agfa HealthCare? Power Drop-and-go cassette buffer Throughput

CR35-SP+ Computed Radiography (CR) System. Innovations in Digital Imaging

MUSICA Nerve Center. Artificial Intelligence. Intelligent tools for your Digital Radiography workflow. Fluoroscopy. Workflow Optimization

CR30-ORACLE CR. with Office Viewer. A Revelation in Computed Radiography. Innovations in Digital Imaging. Solution for Quantum Medical Imaging

Open. the Digitized world. Fuji Computed Radiography

DR Retrofit Kit Package Configuration Integrated PACS

FUSION DCR by icrco. Every year you ll save money with your Fusion DCR every time you don t replace a cassette, and every time you

K ODAK D RYV IEW 8900 LASER IMAGER

DR Retrofit Kit Package Configuration DICOM

The Versatile and Powerful ACLxy. ACLxy

Instant DR in Jordan

CXDI-70C WIRELESS SPECIFICATIONS

Experiences of users in Digital Radiography

Computed Radiography

DELWORKS DR MEDICAL. take the next step

Classic Image Suite. Legendary Reputation...Sensitivity to your budget 'LYLVLRQ RI &DUHVWUHDP

DirectView CR 850 System. A fast, premium single-cassette CR system

Best choice in all DR. Jumong M. SG HealthCare Jumong M Digital radiography specifications

Touch Screen Technology. Classic WAIV. with Touch Screen Technology. Legendary Reputation...Sensitivity to your budget

New spectral benefi ts, proven low dose

Cassette DR Solution. FDR D-EVO G43i. Square shaped cassette enabling enhanced operability and multipurpose use ISS. Wireless

CR Retrofit Kit Package Configuration Integrated PACS

Radiology Physics Lectures: Digital Radiography. Digital Radiography. D. J. Hall, Ph.D. x20893

X-RAY MEDICAL EQUIPMENT

K ODAK D IRECTV IEW CR 850 SYSTEM

Luminos RF Classic. Where value meets performance.

WHITE PAPER. Moving from CR to DR. Optimizing Image Quality and Dose

Small. Smart. Fast. Digital imaging plate system

Maximizing clinical outcomes

you can Portable DR with High Sensitivity. Less is more. CXDI-501C DIGITAL RADIOGRAPHY SYSTEM

COST EFFECTIVE FLAT PANEL DIGITAL RADIOGRAPHY UPGRADE SOLUTIONS

Digital Radiography X-Ray System. X Twin with X Mobil Roesys GmbH [rshsmi] 1/11

Quality assurance: a comparison study of radiographic exposure for neonatal chest radiographs at 4 academic hospitals

you can Portable Digital Radiography. Going places. CXDI-501G DIGITAL RADIOGRAPHY SYSTEM

Performance Meets Simplicity

OTC18 OVERHEAD TUBE CRANE SYSTEM

SAMSUNG SMART DIGITAL RADIOGRAPHY. XGEO GU60A series REDEFINING ERGONOMICS

GE Healthcare. Senographe Crystal The choice is crystal clear

Anapurna RTR3200i LED (+ white)

ADC COMPACT FULL-LEG/FULL-SPINE APPLICATION SOFTWARE USER MANUAL

FMT18 FLOOR MOUNTED SYSTEM

FLIR K2. FLIR-DIRECT.ca

Tomosynthesis. Energy Subtraction. Long View Imaging

HPX1-Plus. For Non-Destructive Testing. THE BENCHMARK IN COMPUTED RADIOGRAPHY.

Quality imaging, practical investment. Philips DuraDiagnost specifications

A True Innovation in Non-Destructive Testing System FUJIFILM COMPUTED RADIOGRAPHY. Series 4 CR

NDT Supply.com 7952 Nieman Road Lenexa, KS USA

Simplifying Digital X-RAY FOR Chiropractic DIGITAL X-RAY RETROFIT COMPLETE DIGITAL X-RAY ACQUISITION & IMAGE MANAGEMENT

K ODAK D IRECTV IEW CR 950 SYSTEM

GE Healthcare. Senographe Crystal The choice is crystal clear

THE CR SPECIALISTS HD-CR CR 35 NDT

SmartRAD. Advanced Digital Radiography System

CT-XGEO GC FTW EN

SPAC265-8W. AC-DC power supply module. Features. Description. Applications

QA-ES III Electrosurgical Analyzer

QA-ES III Electrosurgical Analyzer

Practix. Mobile Radiography. Changing its point of view comes naturally. Practix 300

NI PXI-2797 Specifications 40 GHz 6 1 Terminated 50 Ω Multiplexer

ORTHOPANTOMOGRAPH OP 2D Quality and design

COMPUTED RADIOGRAPHY CHAPTER 4 EFFECTIVE USE OF CR

10/3/2012. Study Harder

RADspeed Pro DIGITAL RADIOGRAPHIC SYSTEM. IBD-RADProAeroDR

X o- System. Chiro- Systems. Chiropractic X-Ray Systems and Digital Solutions. Digital Radiography Computerized Radiography Chiropractic Systems

TECHNICAL DATA. GIOTTO IMAGE SDL/W is pre-arranged for Full Field Digital Biopsy examination with the patient in prone position.

10/26/2015. Study Harder

The Flash IIP Console is the heart of every FCR system. It s designed to maximize productivity in the busiest environments.

Fluke 3540 FC Three-Phase Power Monitor

USRP Contents. Definitions. Conditions SPECIFICATIONS. Software Defined Radio Device

User Manual Veterinary

Ysio Max. The most direct way to the image. Answers for life.

Digital Radiography System

Get more from your images with Symphony Image Processing

USRP Contents. Definitions. Conditions SPECIFICATIONS. Software Defined Radio Device

NI PXI/PXIe-2532 Specifications

MobileDaRt Evolution MX8 Version

Mammography Solution. AMULET Innovality. The new leader in the AMULET series. Tomosynthesis, 3D mammography and biopsy are all available.

Redefining Ergonomics

NI PXI-2532 Specifications

Digitalise your Practice with Ease, Speed and Comfort. NEW from Gendex!

Digital Film Imager UP-DF550

Unit thickness. Unit area. σ = NΔX = ΔI / I 0

Dedicated Veterinary Imaging Solutions Digital, CR and Analog Imaging Solutions for any size patient and any size budget.

AeroDR HD. Wireless Digital Radiography System

:JETI 3020 TITAN. The ultimate upgradeable high resolution production UV-inkjetprinter wíth Flat To Roll option.

X-Ray/ Digital Imaging

NI PXI-2555 Specifications

Get more from your images with Symphony Image Processing

C506-E064. Full digital system. Printed in Japan A-NS

A6500-UM Universal Measurement Card

CS The Ideal Solution for the Transition to Digital

AT-7000 Advanced Wire Tracer

Airmux-400 Specifications

Image Quality. HTC Grid High Transmission Cellular Grid provides higher contrast images

USRP Contents. Definitions. Conditions SPECIFICATIONS. Software Defined Radio Reconfigurable Device

USRP Contents. Definitions SPECIFICATIONS. Software Defined Radio Reconfigurable Device

AUTOMATED AND QUANTITATIVE METHOD FOR QUALITY ASSURANCE OF DIGITAL RADIOGRAPHY IMAGING SYSTEMS

Moving from film to digital: A study of digital x-ray benefits, challenges and best practices

Mammograph FFDM PRODUCT DATA

Fully Integrated Digital Radiography Systems

NI PXI-2557 Specifications

Transcription:

CR SOLUTION The next generation CR System for Digital Mammography and General Radiography. For digital mammography and general radiography Excellent image quality Drop-and-go cassette buffer The next-generation in CR for digital mammography and general radiography, the digitizer unites excellent image quality with the convenience of supporting both standard phosphor plates and needle-based detectors. With a user-friendly drop-and-go buffer that can handle a mix of five cassettes of different sizes, workflow is smoother and more productive. The can be used as a centralized or decentralized digitizer in the radiography department, supporting digital mammography and general radiography. In a centralized environment, it can serve multiple rooms. At the same time, its small footprint means it can be placed in areas where space is limited. Broad range of applications Both needle-based detectors and standard phosphor plates

Needle-based detector Powder phosphor plate Excellent image quality By supporting both standard phosphor plates and needlebased detectors, the unites complete convenience with top image quality, while leveraging a radiography department s existing investments. With standard phosphor plates, the delivers excellent image quality. When used with DirectriX needle-based detectors, the provides excellent image quality with a much higher Detective Quantum Efficiency (DQE). Broad range of applications The combination of needle-based detectors, standard phosphor plates with specific cassettes and image resolution mode makes the ideal for a broad range of applications: General radiography Digital mammography (available with needle-based detectors only) Orthopaedics - extremities Dental Pediatrics and neonatal Full Leg/Full Spine It offers three different image resolution modes: 50 µm pixel pitch (20 pixels/mm), 100 µm pixel pitch (10 pixels/mm) and 150 µm pixel pitch (6.7 pixels/mm). 2

Maximum productivity and smooth workflow The drop-and-go buffer and fast preview eliminate waiting times and facilitate a continuous workflow within the department. The five-cassette drop-and-go buffer can handle a mix of mammography and general radiography cassettes as well as a mix of different sizes of both needle-based detectors and standard phosphor plates. The automatic cassette handling makes highly productive and user-friendly. The right choice To eliminate any confusion, needle-based detector cassettes are gray, while standard phosphor plate cassettes are orange to help the user more easily select the desired cassette. Each plate has an embedded memory that stores the data entered during identification by no-touch radiofrequency tagging. Thus, the identification data and images are linked from the beginning throughout the entire digital processing system. Using as a central digitizer in the radiography department, multiple examination rooms can be supported. With its small footprint, it can fit into tight spaces, including the X-ray room or even a narrow corridor. SAFETY Region Safety EMC Laser EUROPE IEC 60601-1:1988 + EN 60601-1-2:2007 60825-1:1993 + A1:1991: + A2:1995 EN 300 330 2 V1.1.1:2001 A1:1997 + A2:2001 EN 301 489 V1.3.1:2001 USA UL60601-1:2003 FCC part 15 CFR parts 1040.10 and 1040.11 CANADA CSA C 22.2 No.601.1: CSA C 22.2 No. CSA-E60825-1-03 1990 + S1:1994 + A2:1998 601.1.2 3

Needle-based detector: general radiography and mammography Standard phosphor plate: general radiography Needle-based detector Size Spatial resolution Pixel matrix CR HD5.0 General SR 13.77 x 16.92 in (35 x 43 cm) 6.7 pixels/mm 2272 x 2800 CR HD5.0 General 13.77 x 16.92 in (35 x 43 cm) 10 pixels/mm 3408 x 4200 9.44 x 11.81 in (24 x 30 cm) 10 pixels/mm 2256 x 2880 7.08 x 9.44 in (18 x 24 cm) 10 pixels/mm 1656 x 2280 5.90 x 11.81 in (15 x 30 cm) 10 pixels/mm 1344 x 2880 CR HD5.0 AEC 13.77 x 16.92 in (35 x 43 cm) 10 pixels/mm 3408 x 4200 9.44 x 11.81 in (24 x 30 cm) 10 pixels/mm 2256 x 2880 7.08 x 9.44 in (18 x 24 cm) 10 pixels/mm 1656 x 2280 CR HD5.0 FLFS 13.77 x 16.92 in (35 x 43 cm) 10 pixels/mm 3408 x 4368 CR HM5.0 Mammo 9.44 x 11.81 in (24 x 30 cm) 20 pixels/mm 4708 x 5844 7.08 x 9.44 in (18 x 24 cm) 20 pixels/mm 3508 x 4644 Standard phosphor plate Size Spatial resolution Pixel matrix CR MD4.0R General SR 13.77 x 16.92 in (35 x 43 cm) 6.7 pixels/mm 2320 x 2832 13.77 x 13.77 in (35 x 35 cm) 6.7 pixels/mm 2320 x 2320 CR MD4.0R General 13.77 x 16.92 in (35 x 43 cm) 10 pixels/mm 3480 x 4248 13.77 x 13.77 in (35 x 35 cm) 10 pixels/mm 3480 x 3480 9.44 x 11.81 in (24 x 30 cm) 10 pixels/mm 2328 x 2928 7.08 x 9.44 in (18 x 24 cm) 10 pixels/mm 1728 x 2328 5.90 x 11.81 in (15 x 30 cm) 10 pixels/mm 1440 x 2928 CR MD4.0R FLFS 13.77 x 16.92 in (35 x 43 cm) 10 pixels/mm 3480 x 4392 4

Technical Specifications GENERAL Drop-and-go cassette buffer 5 cassettes of mixed sizes input buffer and 5 cassettes of mixed sizes output buffer Power 120 V/60 Hz (USA) Standby 92 W, peak 621 W, fuse 15 A Throughput 14 x 17 in (35 x 43 cm) = approx. 83 plates/ hour Display for status and error indication LCD touchscreen LED status indicator Environmental conditions digitizer Temperature: 59-86 F (15-30 C) Temperature: for use with CR HM5.0 MAMMO Detector: 68-86 F (20-30 C) Humidity: 15-75 % RH EMC compliant with IEC 60601-1-2 Rate of change of temperature: 0.9 F/minute (0.5 C) Greyscale resolution Output to processor: 16 bits/pixel square root compressed Environmental effects Noise level: max. 65 db (A) Heat dissipation: standby 92 W, continuous operation 242 W Dimensions and weight Covered floor space: (W x D x H): 26 x 20 x 48.4 in (66 x 51 x 123 cm) Output buffer included: (W x D x H): 43.5 x 20 x 48.4 in (115 x 51 x 123 cm) Weight: approx.: 397 lbs (180 kg) Configuration requirements NX Workstation and Workflow ID tablet CR HD5.0 Detectors and Cassettes CR MD4.0R Plates and Cassettes Either CR HM5.0 MAMMO Detectors and Cassettes SAFETY Approvals ETL classified CUS, CE Transport details Temperature: -13 to 131 F (-25 to +55 C), -25 C for max. 72 hours, +55 C for max. 96 hours Humidity: 5-95 % RH 5

Agfa and the Agfa rhombus are trademarks of Agfa-Gevaert N.V., Belgium, or its affiliates. DirectriX and the DirectriX logo are trademarks of Agfa HealthCare NV, Belgium or its affiliates. All rights reserved. All other trademarks are held by their respective owners and are used in an editorial fashion with no intention of infringement. The data in this publication are for illustration purposes only and do not necessarily represent standards or specifications, which must be met by Agfa HealthCare. All information contained herein is intended for guidance purposes only, and characteristics of the products and services described in this publication can be changed at any time without notice. Products and services may not be available for your local area. Please contact your local sales representative at agfa.com for availability information. Agfa HealthCare diligently strives to provide as accurate information as possible, but shall not be responsible for any typographical error. 2015 Agfa HealthCare Corp. All rights reserved Published by Agfa HealthCare Corp. 10 South Academy Street Greenville, SC 29601 USA 5S3X2 US 00201504