inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE

Similar documents
A SYSTEM IMPLEMENTATION OF AN ACTIVE NOISE CONTROL SYSTEM COMBINED WITH PASSIVE SILENCERS FOR IMPROVED NOISE REDUCTION IN DUCTS SUMMARY INTRODUCTION

EXPERIMENTAL INVESTIGATIONS OF DIFFERENT MICROPHONE INSTALLATIONS FOR ACTIVE NOISE CONTROL IN DUCTS

Acoustics. Randy Zimmerman Chief Engineer

inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE

EXPERIMENTS ON PERFORMANCES OF ACTIVE-PASSIVE HYBRID MUFFLERS

inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE

Digitally controlled Active Noise Reduction with integrated Speech Communication

MR Modulo Adjustable Constant Airflow Regulator

Welcome Contents Back 1

PanPhonics Panels in Active Control of Sound

inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE

Methods for Reducing Emissions from Switching Power Circuits. A. McDowell, C. Zhu and T. Hubing

Review of splitter silencer modeling techniques

Measuring Instrument Combinations

ANALYTICAL NOISE MODELLING OF A CENTRIFUGAL FAN VALIDATED BY EXPERIMENTAL DATA

inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE

FREQUENCY RESPONSE AND LATENCY OF MEMS MICROPHONES: THEORY AND PRACTICE

Production Noise Immunity

ACTIVE NOISE CONTROL IN HEATING, VENTILATION AND AIR CONDITIONING SYSTEMS. Alessandro Cocchi, Massimo Garai & Paolo Guidorzi

Please refer to the figure on the following page which shows the relationship between sound fields.

Room Acoustics. March 27th 2015

inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE

WITHIN GENERATOR APPLICATIONS

NK / NL series. Rectangular VAV and CAV air volume control terminals

inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE

Qualification of Fan-Generated Duct Rumble Noise Part 2: Results

Acoustic Filter Copyright Ultrasonic Noise Acoustic Filters

Generic noise criterion curves for sensitive equipment

PREDICTION OF RAILWAY INDUCED GROUND VIBRATION

Technical Data Measurement Microphones

PRODUCT DATA. Sound Intensity Calibrator Type Uses and Features

SmartSenseCom Introduces Next Generation Seismic Sensor Systems

JBL Professional Application Note. Loudspeaker Array Low-Frequency Pattern Control using Filtered Array Technology

FAN NOISE & VIBRATION

CHAPTER ONE SOUND BASICS. Nitec in Digital Audio & Video Production Institute of Technical Education, College West

Development of a reactive silencer for turbocompressors

PRODUCT DATA. Sound Intensity Calibrator Type 4297

DESIGN OF VOICE ALARM SYSTEMS FOR TRAFFIC TUNNELS: OPTIMISATION OF SPEECH INTELLIGIBILITY

University of Houston Master Construction Specifications Insert Project Name SECTION MECHANICAL SCOPE OF WORK PART 1 - GENERAL

Meta-Hearing Defect Detection

Façade insulation at low frequencies influence of room acoustic properties

Silent Transformers to Help Consolidated Edison Meet New York City s Ultrastrict Noise Ordinances

LBC 3201/00 Line Array Indoor Loudspeaker

CONTROL Room. Room product for Swegon s WISE system for demand-controlled ventilation. Quick facts Room control against temperature, CO 2

Proceedings of Meetings on Acoustics

A White Paper on Danley Sound Labs Tapped Horn and Synergy Horn Technologies

LINEAR GRILLES AND REGISTERS

Environmental Noise Propagation

Technical Development Program

Vectrino Micro ADV Comparison

Performance of Roadside Sound Barriers with Sound Absorbing Edges

EFFECTS OF PHYSICAL CONFIGURATIONS ON ANC HEADPHONE PERFORMANCE

inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE

Multi-channel Active Control of Axial Cooling Fan Noise

Sound-Tech Xpress Systems The Sound Choice for Acoustical Solutions. Schools/Univ. Commercial/Office. And Much More. Gov./Military

RECTANGULAR CAV AND VAV AIR VOLUME CONTROL TERMINALS NK / NL SERIES

LBC 3200/00 Line Array Indoor Loudspeaker

Noise and vibration control for building services systems

A Desktop Procedure for Measuring the Transmission Loss of Automotive Door Seals

Kitchen exhaust fan GLEB

FLS inch Subcardioid Subwoofer. product specification. Performance Specifications 1


inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE

LFR: flexible, clip-around current probe for use in power measurements

Silent Space Isolation Booths

Proceedings of Meetings on Acoustics

Acoustic Calibration Service in Automobile Field at NIM, China

Overview of Turbofan Engine Noise

Subject: Pappy s Grill and Sports Bar DJ System Acoustical Isolation Study

Loudspeakers. Juan P Bello

Conventional geophone topologies and their intrinsic physical limitations, determined

REVERBERATION CHAMBER FOR EMI TESTING

ACTIVE NOISE CONTROL FOR SMALL-DIAMETER EXHAUSTION SYSTEM

Technical Documentation

Simulation of Cylindrical Resonator with Spiral Neck and Straight Neck to Attenuate the Low Frequency Noise of Muffler

Model LF2500 Low Frequency Sound Silencer

ONLINE TUTORIALS. Log on using your username & password. (same as your ) Choose a category from menu. (ie: audio)

Acceleration Enveloping Higher Sensitivity, Earlier Detection

ODEON APPLICATION NOTE Calculation of Speech Transmission Index in rooms

Radiated Noise of Research Vessels

Use of random noise for on-line transducer modeling in an adaptive active attenuation system a)

2 PDT Coil supply. Contacts rated at. Contact rating per pole and load type. Load Current in 100,000 cycles 100,000 cycles

Audio Engineering Society. Convention Paper. Presented at the 119th Convention 2005 October 7 10 New York, New York USA

MAXXSPEECH PERFORMANCE ENHANCEMENT FOR AUTOMATIC SPEECH RECOGNITION

A FEEDFORWARD ACTIVE NOISE CONTROL SYSTEM FOR DUCTS USING A PASSIVE SILENCER TO REDUCE ACOUSTIC FEEDBACK

Prediction of structure-borne noise generated by a water evacuation duct in heavyweight and lightweight frame constructions

Trademark Notices: Patent Notice:

INDUCT DISSIPATIVE BAR-SILENCER DESIGN

VAV Rectangular Terminal Units

FL283. Dual 8 inch Subcardioid Line Array Module. product specification. Performance Specifications 1

Suppression of Peak Noise Caused by Time Delay of the Anti- Noise Source

Direct Field Acoustic Test (DFAT)

Heating / Air Conditioning Pulsar Radiant Panel ENVIRONMENTAL COMFORT

ECOACCESS GUIDELINE FOR THE ASSESSMENT OF LOW FREQUENCY NOISE

SMART ARRAY. Directivity and definition in a compact format

Figure 1. SIG ACAM 100 and OptiNav BeamformX at InterNoise 2015.

Active control for adaptive sound zones in passenger train compartments

Year 7 Learning Cycle 4 Overview Physics: Light & Sound

Module 1: Introduction to Experimental Techniques Lecture 2: Sources of error. The Lecture Contains: Sources of Error in Measurement

Radio Receiver Architectures and Analysis

Transcription:

Copyright SFA - InterNoise 2000 1 inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering 27-30 August 2000, Nice, FRANCE I-INCE Classification: 3.8 THE FIRST 1000 ACTIVE DUCT SILENCERS INSTALLED IN HVAC SYSTEMS - A SUMMARY OF APPLICATIONS, SUCCESSES, AND LESSONS LEARNED S. Wise*, J.-F. Nouvel**, V. Delemotte*** * Wise Associates, 1409 E. Skyline Drive, 53705, Madison, Wisconsin, United States Of America ** Aldes, 20, Boulevard Joliot Curie, 69694, Venissieux, France *** TechnoFirst, 48, Avenue des Templiers, 13676, Aubagne, France Tel.: 608 2337683 / Fax: 6082337683 / Email: stevewise@att.net Keywords: ACTIVE NOISE CONTROL, FAN NOISE CONTROL, BUILDING NOISE CONTROL, DUCT SI- LENCERS ABSTRACT The authors have been involved in the design and start-up of over 1000 active duct silencers installed in the USA and Europe to silence fans on a variety of Heating Ventilating and Air-conditioning (HVAC) applications. Applications include both retrofit and new construction. This paper answers these questions: What are some of the best examples of installation success? How does one best measure the performance of the active duct silencer? What are the most common flanking noise paths which can be detrimental to the final result? What types of fans are best silenced by active noise control? What is the realistic performance expectation for an active duct silencer? 1 - INTRODUCTION An overview of the commercial (non-residential) applications served by air-handlers with active duct silencers is as shown in the table below: Application Auditoria Cleanrooms Hospitals Labs Offices Schools Ships # of Units 56 322 59 10 447 183 11 Table 1. General office space leads the way by virtue of the fact that it represents a grand proportion of regularly occupied, noise-sensitive spaces. Cleanrooms (for semi-conductor micro-electronic fabrication and also pharmaceutical manufacturing) are an attractive niche for active duct silencers because: 1) with very large quantities of air that must be moved throughout the space, the reduced pressure loss of active silencers greatly reduces the high cost of energy associated with conventional, passive means; and 2) new production machinery to produce high-power chips is extremely sensitive to vibration that can be induced by ductborne low-frequency noise from the huge airhandlers, which is effectively reduced by active silencers. Schools are a cost-sensitive, but growing niche. Notably in the USA, there is growing sentiment among the acoustical consultants, educators, audiologists and architects that the background noise level in schools is so high as to interfere with speech intelligibility, especially for the growing numbers of hearing-impaired youth [1]. Active duct silencers offer greater attenuation in a more compact package than passive attenuators. In hospitals, there is a desire for quiet, well-ventilated areas, but also a concern about the use of porous materials inside the duct, like those generally used in passive attenuation. Active duct silencers can greatly reduce the amount of such materials that must be used. In auditoria and laboratories, the inclusion of active duct silencers enables any required ventilation to be quieted to the threshold of hearing at even the lowest frequencies. With ships, not known for quiet spaces, active duct silencers can fit into the tight duct configurations.

Copyright SFA - InterNoise 2000 2 2 - EVOLUTIONARY TRENDS Over the last 12 years, the cost of active duct silencers has dropped by an order of magnitude, from approximately 10,000 US$ to less than 1,500 US$ per system. At the same time, with multi-channel control and new modular designs, the size of airhandlers that can be treated with active silencers has increased, from 10,000 m3 /h to 100,000 m 3 /h or more. The factory-assembled modularity also eliminates the expensive on-site customization common in the earlier designs. Combining active duct silencers with passive, sound absorbent materials gives attenuation in all octave bands from 31.5 to 8000 Hz. One such embodiment is shown below in Figure 1 [2]. Figure 1: Modular active-passive duct silencer with internal electronic components. 3 - APPLICATION Location #1 in the MER layout shown in Figure 2 identifies the best location for active duct silencers for the supply side, and #11 shows a typical location for the return (ducted or un-ducted). Also seen are 12 other paths for the transmission of noise, or of vibration that can induce noise. Noise attenuation in the duct from the active silencer can only be fully translated to the room if these other paths are controlled. Leaks due to improperly sealed MER openings are a common problem. At 31.5 and 63 Hz, noise transmitted through the MER wall is a limiting factor, especially if the wall construction is gypsum board rather than concrete block. The ability to turn the active system on and off in the field allows the ductborne noise path to be isolated, which in many installations has revealed startling facts about the flanking paths. The noise transmission loss (TL) of wall panels, for example, is normally specified based on standardized testing of specific section sizes. The custom sizes and non-uniform field erection technique have shown a wide range of actual TL. Worse, the standards typically only address the frequency range of 125 to 4000 Hz, so the TL at 31.5 and 63 Hz can indeed be very low, diminishing the benefits of the good performance of the active silencers at those frequencies. Not shown in the graphic are the additional concerns of downstream secondary noise sources such as dampers and diffusers which can create additional noise after the active silencing. Particularly in the USA, fan boxes above suspended ceilings are an additional source in the 125 through 500 Hz octave bands 4 - PERFORMANCE An example of performance is shown in Figure 3. The uncancelled noise spectrum is typical of forwardcurved fans. The cancellation range extends to very low frequencies. The upper frequency limit is the cut-on frequency of the first mode in a 550 mm square (ID) active silencer module. Above that, passive attenuation from sound absorbent materials is sufficient. The performance is measured with an array of in-duct microphone probes. Given the ability to simply turn the system on and off, performance of active silencers, unlike passive silencers, can be measured easily in the duct or in the room at any time. However, since the active system is typically packaged in a passive section, the overall contractual performance includes both effects. There is typically additional passive attenuation of 5-10 db in the low-frequency range, and 25 to 40 db from 500 to 8000 Hz. The smooth, residual spectrum after cancellation is the pseudo-noise floor of the airflow turbulence on the sensing microphones. This pressure level is dependent on the mean flow velocity. In general, active

Copyright SFA - InterNoise 2000 3 Figure 2: Typical mechanical room (MER) layout, with noise and vibration paths enumerated. duct silencers will reduce any fan noise, within the frequency range of effect, to this residual level. This for a given fan noise spectrum, the attenuation will be less at higher velocities as shown in Figure 4 below. A louder spectrum, especially for example the strong blade pass frequency of a backward inclined fan, will provide a strong signal relative to the turbulence, and attenuation will be high even at excess velocities. The turbulence is not simply a direct function of velocity. In a long straight duct, the turbulent energy may be 1% of the total dynamic head, but in tortured flow paths, it could be 5% or more, with a corresponding increase in the pseudo-spl. Therefore, the active duct silencers incorporate some special means of turbulence suppression for the microphones [3]. Predicting the noise in an HVAC system with active duct silencers is easier than would first appear. The beginning step for the engineer designers of the HVAC system is to consult with the active duct silencer manufacturer to select a design velocity that will allow cancellation down to the desired in-duct SPL. Then, the anticipated active attenuation will be given as an average value, with a ± 5 db spread. This is not a design tolerance that must be added to uncertainties in the fan sound power. Rather, the active attenuation will, in effect, compensate for louder fan noise. If the fan is louder than predicted, the cancellation will increase because of the improved acoustic signal. Below is a summary of an installation of 20 nominally identical air handlers. The test standard for fan noise data at 63 Hz has an acknowledged tolerance of ± 6 db. As installed, the fans also delivered a wide spread of incident sound power levels to the active silencer. But the active systems achieved greater cancellation on the noisier fans, so the spread of residual, in-duct sound power levels was an acceptable ± 2 db tolerance. Thus the designer can, with confidence, use average fan noise and silencer attenuation values in predictions. 63 Hz Active Off Active Attenuation 63 Hz Active On Average db 95.1 18.1 76.9 Std. Dev. 2.6 2.3 1.2 Minimum 88 13 75 Maximum 101 23 79 Scatter +6 / -7 +5 / -5 +2 / -2 Table 2: Summary of measured results (in-duct SPL) for 20 Identical AHUs and active duct silencers.

Copyright SFA - InterNoise 2000 4 Figure 3: In-duct attenuation for 550 mm 550 mm modules on forward-curved fan. REFERENCES 1. J. G. Lilly, Understanding Problem Noise in the Classroom, ASHRAE Journal, Vol. 42(2), 2000 2. Christian Carme et al., Active Sound Attenuation Device To Be Arranged Inside a Dict, Particularly For the Sound Insulation of a Ventilating And/Or Air-conditioning System, Patent PCT/FR96/01694 3. Mats Abom et al., Turbulence Noise Suppression Methods for ANC in Duct, In Active 99, 1999

Copyright SFA - InterNoise 2000 5 Figure 4: Effects of air turbulence on residual noise level after cancellation.