City, University of London Institutional Repository

Similar documents
City, University of London Institutional Repository

WRIST BAND PULSE OXIMETER

Design of Wearable Pulse Oximeter Sensor Module for Capturing PPG Signals

Pulse Oximetry. Principles of oximetry

Principle of Pulse Oximeter. SpO2 = HbO2/ (HbO2+ Hb)*100% (1)

Masimo Corporation 40 Parker Irvine, California Tel Fax

DEPARTMENT OF ELECTRICAL ENGINEERING AND COMPUTER SCIENCE MASSACHUSETTS INSTITUTE OF TECHNOLOGY CAMBRIDGE, MASSACHUSETTS 02139

An Advanced Architecture & Instrumentation for Developing the System of Monitoring a Vital Sign (Oxygen Saturation) of a Patient.

DESIGN AND PROTOTYPING OF A MINIATURIZED SENSOR

Low-cost photoplethysmograph solutions using the Raspberry Pi

ELR 4202C Project: Finger Pulse Display Module

D5.1 Report on the design of a fibre sensor based on NIRS

PULSE OXIMETRY MODULE TO IMPLEMENT IN TEAM MONITOR OF VITAL SIGNS

PHYSIOLOGICAL SIGNALS AND VEHICLE PARAMETERS MONITORING SYSTEM FOR EMERGENCY PATIENT TRANSPORTATION

E-health Project Examination: Introduction of an Applicable Pulse Oximeter

Medical Electronics Dr. Neil Townsend Michaelmas Term 2001 ( Pulse Oximetry: The story so far

SFH Photoplethysmography Sensor

Signal Extraction Technology

PHOTOPLETHYSMOGRAPHIC DETECTOR FOR PERIPHERAL PULSE REGISTRATION

Quad Rat Vitals Monitor. Client: Dr. Alex Converse. Advisor: Dr. Tom Yen. Group Members: Jack Ho Team Leader. Nathan Werbeckes Communicator

Quad Rat Vitals Monitor

LOW POWER WIRELESS PULSE OXIMETER TERMINAL

The OXY100C outputs four signals simultaneously, as shown in this graph: O 2 Saturation (beat-by-beat, CH 1) Pulse Waveform (beat-by-beat, CH 5)

DESIGN OF A PHOTOPLETHYSMOGRAPHY BASED PULSE RATE DETECTOR

Design & Implementation of Pulseoxymeter to Measures the Oxygen Saturation in Blood

DESIGN A MEDICINE DEVICE FOR BLOOD OXYGEN CONCENTRATION AND HEART BEAT RATE

PhO 2. Smartphone based Blood Oxygen Level Measurement using Near-IR and RED Wave-guided Light

Chapter 2. Design and development of blood volume pulse sensor and heart rate meter. Abstract

Arterial pulse waves measured with EMFi and PPG sensors and comparison of the pulse waveform spectral and decomposition analysis in healthy subjects

6.111 Final Project Proposal HeartAware

Laboratory Activities Handbook

City, University of London Institutional Repository

A multiplexed electronic architecture for. opto-electronic patch sensor to effectively monitor heart rate and oxygen saturation.

Data acquisition and instrumentation. Data acquisition

REMOTE HEALTH MONITORING SYSTEM USING PIC MICROCONTROLLER

HUMAN BODY MONITORING SYSTEM USING WSN WITH GSM AND GPS

Health and Fitness Analog solution. Wenbin Zhu Medical BDM June, 2015

BENG 186B Principles of Bioinstrumentation. Week 7 Review. Solutions

Design Considerations for Wrist- Wearable Heart Rate Monitors

Biosignal Data Acquisition and its Post-processing

A Twenty-Four Hour Tele-Nursing System Using a Ring Sensor

common type of cardiac diseases and may indicate an increased risk of stroke or sudden cardiac death. ECG is the most

Intelligent Pillow for Heart Rate Monitor

SCXI 8-Channel Isolated Analog Input Modules

Dash 3000, 4000 & 5000

Next Generation Biometric Sensing in Wearable Devices

P.O. Pro WIRELESS REFLECTANCE PULSE OXIMETER Design 2. December 1, 2004 Team # 3 James Hart Sofia Iddir Rob Mahar Naomi Thonakkaraparayil

Design of Virtual Sphygmomanometer Based on LABVIEWComparison, Reflection, Biological assets, Accounting standard.

A Technology Overview of the Nellcor OxiMax Pulse Oximetry System

APPLICATION OF HEART PHOTOPLETHYSMOGRAPHY

Design of Arterial Blood Pressure, Heart Rate Variability, and Breathing Rate Monitoring Device. Mastan Singh Kalsi

Keywords: Electronic Patch, Wireless Reflectance Pulse Oximetry, SpO2, Heart Rate, Body Temperature.

WIRELESS REFLECTANCE PULSE OXIMETER DESIGN AND PHOTOPLETHYSMOGRAPHIC SIGNAL PROCESSING KEJIA LI. B.S., Zhejiang University, 2008 A THESIS

Innovative Experimental Low Cost Electronics Operated Instrumentation for Wearable Health Systems with High Resolution Physiological Measurements

INTEGRATION OF LOW COST SpO2 SENSOR IN A WEARABLE MONITOR

INVESTIGATION OF NEW ELECTRO - OPTICAL TECHNIQUES FOR MONITORING PATIENTS WITH COMPROMISED PERIPHERAL PERFUSION IN ANAESTHESIA

(51) Int Cl.: A61B 5/00 ( ) G06F 17/00 ( )

PX8000 Precision Power Scope with Features of High-accuracy Power Meter and Waveform Measuring Instrument

Design and Development of a Wireless Pulse Oximeter System

EMG Sensor Shirt. Senior Project Written Hardware Description April 28, 2015 ETEC 474. By: Dylan Kleist Joshua Goertz

MASIMO RADICAL 7 Signal Extraction Pulse CO-Oximeter

Pulse Oximetry Dave Hoff Roy Zhang Tad Stalter Mike Carlson

Development of an Optical Heart Rate Monitor using a Microchip PIC24-microcontroller based development board

Pulse Sensor Individual Progress Report

Design of PID Control System Assisted using LabVIEW in Biomedical Application

Design of the Pulse Oximetry Measurement Circuit and Its Sensing System Based On CMOS

Design and Implementation of Digital Stethoscope using TFT Module and Matlab Visualisation Tool

medlab Two Channel Invasive Blood Pressure OEM board EG 02000

Optical Theremin Critical Design Review Yanzhe Zhao, Mason Story, Nicholas Czesak March

Design and Development of a Two Channel Telemedicine System for Rural Healthcare

School of Electronic Science and Engineering, Nanjing University of Posts and Telecommunications, Nanjing, , China

Digital temperature controllers

The PmodIA is an impedance analyzer built around the Analog Devices AD bit Impedance Converter Network Analyzer.

PULSE OXIMETRY SIMULATOR

International Journal of Electronics and Communication Engineering & Technology (IJECET), ISSN COMMUNICATION ENGINEERING & TECHNOLOGY (IJECET)

A Novel Ring Shaped Photodiode for Reflectance Pulse Oximetry in Wireless Applications

Wireless Sensor Network for Intra-Venous Fluid Level Indicator Application

ELG3336 Design of Mechatronics System

Robotic Development Kit. Powered using ATMEL technology

Fig. 1 Tachometer Built from Old CD, DC Motor, and Photogate

VivoSense. User Manual - Equivital Import Module. Vivonoetics, Inc. San Diego, CA, USA Tel. (858) , Fax. (248)

Fast IC Power Transistor with Thermal Protection

Monitoring of Intravenous Drip Rate

INSTALLATION & OPERATING INSTRUCTIONS

MULTIPLE PULSE WAVE MEASUREMENT TOWARD ESTIMATING CONDITION OF HUMAN ARTERIES

S2014, BME 101L: Applied Circuits Lab 7: Optical Pulse Monitor

Analytical Chemistry II

GSM BASED PATIENT MONITORING SYSTEM

New type ADC using PWM intermediary conversion

5v AC R. 12v. 1kohm. F=35KHz oscilloscope. 3 Final Project OFF. ON Toggle Switch. Relay 5v 2N3906 2N uF LM311. IR Detector +5v GND LED PNP NPN

Low Cost Laser Diode Controller, High Frequency Modulator and Light Pulse Detector for Students Laboratories (*)

PC-OSCILLOSCOPE PCS500. Analog and digital circuit sections. Description of the operation

An Ultra-Low-Power Pulse Oximeter Implemented With an Energy-Efficient Transimpedance Amplifier

Clinical evaluation of a novel adaptive algorithm for automated control of oxygen therapy in preterm infants on non-invasive respiratory support

EE 300W 001 Lab 2: Optical Theremin. Cole Fenton Matthew Toporcer Michael Wilson

Experimental Analysis of Luminescence in Printed Materials

M328 version ESR inductance capacitance meter multifunctional tester DIY

Optical Attenuation Sensor for Process Control

2013 National micromedic Contest Report Team Name: Bauch & Allen

Photodiode types. Fig Transistor Optocouplers & Opto Sensors

Transcription:

City Research Online City, University of London Institutional Repository Citation: Rybynok, V., May, J.M., Budidha, K. and Kyriacou, P. A. (2013). Design and Development of a novel Multi-channel Photoplethysmographic Research System. In: 2013 IEEE Point-of-Care Healthcare Technologies (PHT). (pp. 267-270). IEEE. ISBN 978-1-4673-2765-7 This is the accepted version of the paper. This version of the publication may differ from the final published version. Permanent repository link: http://openaccess.city.ac.uk/3545/ Link to published version: http://dx.doi.org/10.1109/pht.2013.6461336 Copyright and reuse: City Research Online aims to make research outputs of City, University of London available to a wider audience. Copyright and Moral Rights remain with the author(s) and/or copyright holders. URLs from City Research Online may be freely distributed and linked to. City Research Online: http://openaccess.city.ac.uk/ publications@city.ac.uk

Design and Development of a novel Multi-channel Photoplethysmographic Research System V. Rybynok 1, J. M. May 2, K. Budidha 3, and P. A. Kyriacou 4, Senior Member, IEEE Abstract Photoplethysmography (PPG) is a noninvasive optical technique used in detecting blood volume changes in vascular tissue. In recent years, photoplethysmography has generated renewed interest among researchers, particularly due to its potential for widespread clinical applications beyond estimating heart rate and arterial oxygen saturation. Progress in these areas of research is dependent on PPG systems with the ability to record raw photoplethysmographic signals with high signal-to-noise ratio, ideally from more than one channel and one wavelength, for real-time or retrospective analysis. In this work we present the design, development and validation of such a modular PPG system. Zen PPG - a portable (16.0 x 10.3 x 5.4 cm) battery operated dual channel, dual wavelength system with the capability to operate with commercial sensors was developed and calibrated using a FLUKE Index 2 SpO 2 simulator. A brief study has been conducted on a small group of healthy volunteers to demonstrate the functionality of the system. Red and Infrared PPG signals obtained from volunteers were used to estimate SpO 2 and heart rate. These results were compared with simultaneously acquired data from a commercial pulse oximeter (Masimo Radical 7). The SpO 2 values showed close correlation between commercial and custom made system (Channel 1: r 2 = 0.978; channel 2: r 2 = 0.708). I. INTRODUCTION Optical spectroscopic investigations of human tissue and blood date back as far as the late nineteenth and early twentieth century, where Hertzman and Aoyagi are widely credited with introducing Photoplethysmography (PPG) [1]. PPG is a non-invasive optical measurement technique used to detect blood volume changes in peripheral vascular bed [2]. Photoplethysmography is based on the absorption properties of vascular tissue when it is transilluminated by light. The emitted light, which is made to traverse the skin, is reflected, absorbed and scattered in the tissues and blood [2]. The scattered light which reaches the other end of the tissue is detected by a photodetector. The intensity of the Manuscript received 28 th September 2012 1 V. Rybynok is with the School of Engineering and Mathematical Sciences, 2 J.M.May is with the School of Engineering and Mathematical Sciences, 3 K. Budidha is with the School of Engineering and Mathematical Sciences, 4 P.A. Kyriacou is with the School of Engineering and Mathematical Sciences, (email: p.kyriacou@city.ac.uk) scattered light which reaches the photodetector is measured and the variations in the photodetector current are assumed to be related to blood volume changes underneath the probe. These variations are electronically amplified and recorded as a voltage signal called the photoplethysmograph. The photoplethysmograph comprises of a pulsatile ( AC ) physiological component synchronized with the cardiac cycle, riding on a slowly varying (DC) baseline [2]. These photoplethysmographs obtained from tissue vasculature by shining light at two different wavelengths (red and infrared) is used in estimating arterial oxygen saturation (SpO2), and this technique is known as pulse oximetry [2]. In recent years, due to the technical advancements in signal processing algorithms, photoplethysmography has gained renewed interest. Particularly since its potential use as a diagnostic tool for measuring physiological variables beyond arterial oxygen saturation and heart rate has been demonstrated. These variables include vascular diagnostics, blood pressure measurement, venous oxygen saturation [3], and fluid response. Another area in which photoplethysmography has gained immense interest is in the development of unique sensor technology, which can be used to estimate physiological variables in conditions of compromised peripheral blood supply [2]. These sensor technologies are usually validated by acquiring data from custom build and manufacturer systems. All these advancements in the field of photoplethysmography are dependent on the ability of PPG systems to produce high quality raw photoplethysmographic signals. Also, as most of these studies are performed in clinical environments such as ITU, ICU and operating theatres it is a tedious process acquiring data from custom made and OEM pulse oximeters simultaneously for real time or retrospective analysis. This illustrates the need for a portable, multi-channel, multi wavelength, multi parametric PPG system. Hence we propose Zen PPG A dual channel, dual wavelength PPG research system, which combines the advantages of standardization of instrumentation, compatibility with commercial probes and the ability to customize the system for specific projects. In this paper we introduce the design and development of the proposed technology in detail and provide a preliminary assessment of its performance. II. METHOD A modular and constructive design approach was implemented in the design of Zen PPG. The PPG system was constructed to pre-process, record and display raw PPG signals from two channels and two wavelengths on a laptop personal computer. The main parts of the system are: a

system bus, PPG modules (current supplies, probe connector board and transimpedance amplifiers) and power supply conditioning board. All the modules were designed to be as simple as possible allowing incremental improvement during subsequent development of the system. The mechanical structure of the system is shown in Fig 1. Figure 1. Shows the mechanical structure of Zen PPG A. Mechanical Construction of the Processing System Printed circuit boards (PCB) of all the modules along with a dual 9v PP3 battery case were housed in a rectangular portable unit measuring 16.0 x 10.3 x 5.4 cm. Modern surface mount JFET technology has been used for analogue circuitry on all the PCB s. The front of the unit incorporates two standard D9 connectors for connecting two probes, and an on/off switch to control the system. The rear panel consists of a 68-pin serial bus connector for interfacing to a National Instruments data acquisition card and access to two trimmers which can be used to control the LED currents. This modular approach to the design provides efficient troubleshooting and easy customization of the system for specific research projects. For instance, the current hardware multiplexing core board can easily be exchanged with a software controlled core board. B. Electrical design of Zen PPG Zen PPG consists of 6 PCB modules, each with specific functions. 1) System Bus: The system bus as shown in figure 1, consists of six (three on each side) receptacle 50 way SAMTEC surface mount connectors. It is designed in such a way that every single pin in any connector corresponds to the same pin in all the connectors. Since all the 50 pins on every connector are the same, it provides a medium of interaction between various modules. All the PPG modules and the power supply conditioning board are furnished with gold plated through-hole right angle 50 way headers which can be inserted into the connectors on the bus board. 2) Power supply module: The whole PPG system is powered with two rechargeable 9v PP3 batteries. The power supply conditioning board generates three different voltage outputs from the ±9v battery supply. Positive (MC78M05CDTG) and negative (MC79M05CDTG) voltage regulators generate ±5v supply (INEG and IPOS), which is used for multiplexing and driving LED currents in the system. A +3.3v and -1.4v supply is generated using MCP1703T and LT1964ES5 voltage regulators. This supply is used to power all the analogue chips on the transimpedance and core board. A digital power supply of 3.3v is generated using a positive voltage regulator (MCP1703T). This supply is used to operate the micro-controller on the core board. 3) PPG Modules: The PPG modules include the core, current source, transimpedance and probe board. a) Core Module: The core board is the heart of the processing system. An Atmel ATtiny 2313-20SU microcontroller is used as a Master clock and timing generator. The micro-controller is programmed using Atmel STK500 micro-controller programmer. The STK500 can be connected to the micro-controller on the core board by 6-pin ISP header. The micro-controller is programmed to generate digital switching signals at a frequency of 500Hz. These digital signals directly correspond to the LED switching. The PPG system has an added capability of control over LED currents. The LED currents can be controlled digitally on one channel and by using manual trimmers on the other. The digital control over LED currents on channel one is possible by generating an analogue positive and a negative 5V (max) signals from a 16 bit data acquisition card (DAQpad-6015 National instruments corporation, Austin, Texas) and passed into the system via 64 pin NI connector on the core board. These ±5V signals from the DAQ card are passed through a ±5V to ±1V attenuator on the core board and then passed through a dual 4-channel analogue multiplexer (MC1405BD). For the second channel, a positive voltage regulator on the core board generates a 1V signal which is passed through an inverting and a non-inverting trimming attenuator to generate a + and -1V (max) output signals. These signals are then passed through the same multiplexer. The multiplexer generates two digital signals, varying from +1v to -1V depending on the clocks form the microcontroller as shown in Fig 2. The time controlled signals from the micro-controller were also used for synchronizing the demultiplexer that separated the mixed PPG signals. The micro-controller can be programmed to demultiplex PPG s up to four wavelengths along with ambient light. Low pass filters with a cut-off frequency of 40Hz were then used to remove the high frequency switching noise from the demultiplexed raw signals. All the PPG output signals were

then digitised by a 16-bit data acquisition card and displayed on the laptop. use most manufacturer probes with D9 connectors without any additional requirements. c) Transimpedance Module: The transimpedance module consists of two identical transimpedance amplifiers. The photocurrents from the photodetector are converted into a mixed voltage signal consisting both R and IR PPGs. These mixed signals are then passed through the demultiplexer via the bus. The transimpedance amplifier is a simple Op-Amp with a gain resistor in negative feedback configuration. 4) Preliminary Evaluation and Calibration: Preliminary evaluation of the system was carried out by measuring R and IR PPGs from both the channels using two Masimo SET LNCS DCI adult reusable sensors (Masimo Inc., Irvine, CA, USA). The signals were acquired using 16 bit data acquisition card (DAQpad-6015 National instruments corporation, Austin, Texas). A LabVIEW virtual instrument (VI) was programmed to display the raw PPG signals on the Laptop PC. The ratio-of-ratios ('R' value) was calculated using ( ) Figure 2. Flow diagram demonstrating the function of Core and current source modules b) Current Source Module: Two identical current sources drive R (red) and IR emitters on both the channels. Each current source is designed to switch R and IR emitters at 500 Hz (each emitter is switched on every 2ms for an interval of 0.5ms). As shown in figure 2, the transconductance coefficient reduces -1v to 1v multiplexed signals from the core board to +100 mv to -100mV. This is to limit the current to a maximum of 100 ma. These signals are then passed through the transconductance amplifier which converts voltage to current. The transconductance amplifier used in the system is a modified Howland current source with a NPN-PNP transistor. When the current source input signal is positive, the NPN transistor is active and switches one emitter on, and when the input is negative, the PNP transistor is active switching the other emitter on. The system also has an added capability to continuously monitor emitter currents. This is achieved by inputting the voltages before the load resistor and the currents after the load resistor into an instrumentation amplifier as shown in Fig 2. The instrumentation amplifier produces an output voltage equivalent to the current across the LED s, which is passed through the bus into the core board and into the DAQ card for acquisition. a) Probe Module: The probe board consists of two standard D9 connectors. The pin configuration for emitters and photodiode on the D9 connector is exactly the same as the manufacturer probes. This gives the flexibility to The R value was then used to compute arterial oxygen saturation using an empirically derived calibration equation [1]. SpO 2 = 110 25 R (1) A peak detection algorithm was implemented in LabVIEW to measure heart rate from PPG signals. The performance and accuracy of both the channels on prototype system were tested using Index 2 SpO 2 simulator (Fluke Biomedical, Everett, WA, USA).These assessments were performed by using a pre-loaded Masimo calibration curve in the simulator and a Masimo reusable finger probe. The SpO 2 values were decreased from 100% to 70% with 1% resolution, while keeping the heart rate constant at 70 beats per minute. Using the value of SpO 2 obtained from these assessments at each set SpO 2 level, calibration curves for both the channels have been derived. Although, good quality PPG signals and SpO 2 results were obtained using an SpO 2 simulator, in reality saturations values are limited by external, individual and technical factors. So in order to test the functionality and the accuracy of ZenPPG system on individuals, a brief study has been conducted on 7 healthy volunteers (male and female aged 21-31). In this study, PPG signals were recorded from first and second fingers of the right hand using two Masimo SET LNCS DCI adult reusable sensors (Masimo Inc., Irvine, CA, USA). These signals were then used to calculate SpO 2 values, which were compared with simultaneously-recorded SpO 2 values from a Masimo Radical-7 commercial pulse oximeter used on the first finger of the left hand.

III. RESULTS The results of the assessment using both the channels of the ZenPPG system in conjunction with the Masimo probe were used to produce calibration curves as shown in Fig 3. A second degree polynomial was used to derive the following calibration functions: ( ) (2) ( ) (3) Where R is the ratio-of-ratios determined from the red and infra-red AC signals IV. CONCLUSION A novel dual channel and dual wavelength photoplethysmographic system has been developed and tested. The pilot volunteer study proved the ability of the system to produce high quality PPGs and accurately estimate SpO 2 values from either commercial or custom made sensors. A full scale hypoxic study needs to be conducted to accurately calibrate the system and generate new calibration functions. The capability of the system to acquire signals from four wavelengths and four channels with minor effort makes the system highly suitable for a wide range of physiological investigations. The system possesses various advantages over commercially available devices; the modular design of Zen PPG allows the user to customize the system to any specific project requirements. The dual channel nature of the system gives the user an advantage in terms of complexity by not having to have to stack two pulse oximeters for comparative studies. The availability of digital current over LED currents and the modern JFET technology used in the system makes ZEN PPG power efficient when running from batteries. Figure 3. Calibration curve derived using ZEN PPG Good quality PPG signals were obtained from all seven volunteers. Table 1 shows the SpO2 values obtained from seven healthy volunteers using the ZenPPG system and the commercial pulse oximeter. SpO 2 values were calculated from the raw signals obtained from both channels using equation (2) and (3) derived from Channel 1 and 2. It can be seen that SpO 2 results from the commercial system showed very good agreement with ZenPPG Channel 1 (r 2 = 0.978) and fair agreement with ZenPPG Channel 2 (r 2 = 0.768). REFERENCES [1] J. G Webster, Design of Pulse Oximeters, 1st ed. Bristol: Institute of Physics Publishing, 1996. [2] P. A. Kyriacou, Pulse Oximetry in the oesophagus, Physiological Measurement, vol. 27, pp. R1-R35, 2006. [3] Z. D. Walton, P. A. Kyriacou, D. G. Silverman, and K. H. Shelley, Measuring venous oxygenation using the photoplethysmograph waveform, Journal of Clinical Monitoring and Computing, Vol. 24, pp. 295, 2010 Subject # Masimo Radical-7 ZenPPG Ch.1 ZenPPG Ch.2 1 95 94.76 95.57 2 99 99.61 98.56 4 97 97.84 97.61 4 98 97.84 94.85 5 95 94.19 92.79 6 98 98.56 97.41 Mean 97.0 97.13 96.13 Table 1: Comparison of SpO 2 values obtained from Masimo Radical-7 pulse oximeter with both the channels in ZenPPG.