LM Test Report. for Elec-Tech International Co., Ltd. BR40 LAMP Model: XX(XX:01-10), WBR40L27S2A

Similar documents
LM Test Report. for Elec-Tech International Co.,Ltd. LED PAR30 Spot light Model: XX(XX:41-50)

LM Test Report. for Elec-Tech International Co.,Ltd. LED CEILING LIGHT Model: XX(XX: 01-10)

LM Test Report. for Elec-Tech International Co.,Ltd. LED CEILING LIGHT Model: XX(XX: 61-70)

LM Test Report. for Elec-Tech International Co.,Ltd. LED CEILING LIGHT Model: XX(XX: 01-10)

LM Test Report. for. Philips (China) Investment Co., Ltd. InstantFit LEDtube Model:

Report No.: HZ f. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

LM Test Report. for Maxlite SK America Inc. 2*4 Retrofit Kits Model: RKT4514U5550DV

LM Test Report. for Maxlite SK America Inc. WALLPACK Model: MLSWP30LED50DS

Report No.: HZ j. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

LM Test Report. for Maxlite Inc. LED Canopy Model: MLCAN20LED50

Report No.: HZ h. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

LM Test. for LED. Cabinet

LM Test Report. for EiKO Global, LLC. 25W Floodlight Model: FLM-2C-N-U

Report No.: HZ h/R1. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

Report No.: HZ b. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

Report No.: HZ b. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

Report No.: HZ c/R1. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

Report No.: HZ a/R2. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

Report No.: HZ a/R2. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

(Lumens) Stabilization Time CRI (K) (Light & Power) Table 1 Executive Data Summary

(Lumens) Stabilization Time CRI (K) (Light & Power) Table 1 Executive Data Summary

LM Test Report. For. T8 LEDTUBE Model: LED9WT8 F/24/850K-G7D

Report No.: HZ k/R1. (Lumens) Stabilization Time CRI (K) (Light & Power) Table 1: Executive Data Summary

L Test Report. LED TUBE 1odel: LED11.5WT8/48/850-PET-G7DR

Morris Products 53 Carey Road, Queensbury, NY 12804

Report No.: HZ a. 60 mins Note. 4000K, frosted lens Table 1: Executive Data Summary

Catalog Number UPC Number LED Spot Bullet Flood Light 42W 4204 Lumens White

Cat# LED Classic Large Wall-Pack

Report No.: HZ c

Report No.: HZ w. Stabilization Time (Light & Power) CRI. Table 1: Executive Data Summary. Figure 1- Overview of the sample

Report No.: HZ d

Catalog Number UPC Number LED Spot Bullet Flood Light 15W 1620 Lumens Bronze

NVLAP LAB CODE LM Test Report. For. MaxLite Inc. (Brand Name: MaxLite) 12 York Ave West Caldwell NJ 07006

Report No.: EASZE Page 2 of 14

NVLAP LAB CODE LM Test Report. For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD. (Brand Name: GI LED LIGHTING)

LM Test Report

LM Test Report

71332 LED Dusk To Dawn (Area Light)

NVLAP LAB CODE LM Test Report. For SHENZHEN BONLD ELECTRONICS CO.,LTD. (Brand Name: BONLD)

LM Test Report

NVLAP LAB CODE LM Test Report. For. Maxlite Inc. (Brand Name: ) 12 York Avenue, West Caldwell, NJ

LM Test Report

NVLAP LAB CODE LM Test Report. For. Maxlite INC. (Brand Name: Maxlite) 12 York Ave., West Caldwell, NJ 07006

NVLAP LAB CODE LM Test Report. For. Shenzhen OKT Lighting Co.,LTD. (Brand Name: OKT LIGHTING)

NVLAP LAB CODE LM Test Report. For. Shenzhen OKT Lighting Co.,LTD. (Brand Name: OKT LIGHTING)

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MAXLED) 12 York Avenue West Caldwell, NJ

Cat# LED Wall-PACK

NVLAP LAB CODE LM Test Report. For GREEN LOGIC LED ELECTRICAL SUPPLY INC. Outdoor Full-Cutoff Wall-mounted Area Luminaire

LED Floodlight. RoHS. Model: inner box: L 17" X W 12.5" X H 9.33" 1PCS AC 50/60HZ. Input Voltage 0.85A MAX. Input Current 78 W.

LM Test Report. For. Torshare Ltd. (Brand Name: TORSHARE)

LM Test Report. For FALKOR INDUSTRY INC. (Brand Name: Falkor Lighting) 5580 Bandini Blvd Bell,CA USA

LM Test Report. For FALKOR INDUSTRY INC. (Brand Name: Falkor Lighting) 5580 Bandini Blvd Bell,CA USA

NVLAP LAB CODE LM Test Report. For MAXLITE,INC. (Brand Name: N/A) 12 YORK AVENUE WEST CALDWELL,NJ 07006

LM Test Report. For. Eternal Shine Technology Co.,Ltd. (Brand Name: EST) ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China

LM Test Report. For. GREEN LOGIC LED ELECTRICAL SUPPLY INC (Brand Name: GLLUSA) Shenfubao Industry Park, Bonded area, Futian District,Shenzhen

NVLAP LAB CODE LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name: N/A) 188 S. Northwest Highway Cary, IL 60013

NVLAP LAB CODE LM Test Report. For. Hocan Group Co.,Ltd. Rm 1902, Easey Comm Bldg Hennessy Rd Wanchai, HONG KONG

NVLAP LAB CODE LM Test Report For. Outdoor Pole/Arm-mounted Area and Roadway Luminaires

NVLAP LAB CODE Energy Star Test Report. For. Shenzhen OKT Lighting Co.,LTD

LM Test Report. For. Builders Pack. ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China

LM Test Report. For. Eternal Shine Technology Co.,Ltd. (Brand Name: EST) ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China

Approved Method: Electrical and Photometric Measurements of Solid-State Lighting Products

NVLAP LAB CODE LM Test Report. For EIKO GLOBAL, LLC W 84th St., Shawnee, KS

REVOLUTION LIGHTING TECHNOLOGIES INC

NVLAP LAB CODE LM Test Report. For ATG ELECTRONICS CORP. (Brand Name: N/A) th Street Rancho Cucamonga, CA 91730

NVLAP LAB CODE LM Test Report. Outdoor Non-Cutoff and Semi-Cutoff Wall-mounted Area Luminaires. Model name(s): WML-50W

NVLAP LAB CODE LM Test Report. For. LED Waves, Inc st. Ave. Brooklyn, NY USA. Linear Retrofit Kits for 2x2 Luminaires

NVLAP LAB CODE LM Test Report. Outdoor Full-Cutoff Wall-mounted Area Luminaires. Model name(s): LWA-50W

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD. (Brand Name: THAILIGHT)

NVLAP LAB CODE LM Test Report. For HOCAN GROUP CO LTD. (Brand Name: N/A)

LM Test Report. For. Eternal Shine Technology Co.,Ltd. (Brand Name: EST) ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China

NVLAP LAB CODE LM Test Report. Outdoor Non-Cutoff and Semi-Cutoff Wall-mounted Area Luminaires

LM Test Report. For. Revolution Lighting Technologies, Inc. (Brand Name: ) 2280 Ward Ave. Simi Valley, CA

LM Test Report. For. Builders Pack. ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China

NVLAP LAB CODE LM Test Report. For HOCAN GROUP CO LTD. (Brand Name: N/A)

NVLAP LAB CODE LM Test Report. For HOCAN GROUP CO LTD. (Brand Name: N/A)

NVLAP LAB CODE LM Test Report. For BEYOND LED TECHNOLOGY Mountain Industrial Blvd. Suite A-1 Tucker, GA USA

Test Report. Report No.: EED35I Page 1 of 10. Customer : EIKO GLOBAL LLC Address : W 84TH ST SHAWNEE, KS USA

NVLAP LAB CODE LM Test Report. For. LED2 Lighting Group, Inc. (Brand Name: LED2) 600 Minnesota Ave, Kansas City, KS 66101

NVLAP LAB CODE LM Test Report. For. LED2 Lighting Group, Inc. (Brand Name: LED2) 600 Minnesota Ave, Kansas City, KS 66101

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD. (Brand Name: THAILIGHT)

LM Test Report. For KEYSTONE TECHNOLOGIES LLC. (Brand Name: KEYSTONE) 1390 Welsh Road North Wales, PA 19454

NVLAP LAB CODE LM Test Report. Outdoor Full-Cutoff Wall-mounted Area Luminaires

57-100W-XXK-WPH12-SG W-40K-WPH12-SG W-57K-WPH12-SG

RoHS. Model: VAC 50/60HZ.83A Max 100W

QPL ID # PLG2YNJ831VZ

RoHS VAC 50/60HZ 0.38A Max W PF LM LM/W x 90

RoHS. Model: VAC 50/60HZ 0.127A Max 14.6 W PF LM LM/W x90 Aluminium Housing + Polycarbonate Lens

Eternal Shine Technology Co.,Ltd. EST

RoHS VAC 50/60HZ 1.8A Max 150W PF LM 123 LM/W x 90 Aluminium + PC Lens 36-60VDC 4.4A 88% Philips 3030 LED 36 PCS

RoHS QPL ID # PLC6V1PABNUJS

Direct to wall VAC / 30W PF ,290 LM 110 LM/W B2-U0-G1. Alluminium + Tempered Glass 24-48VDC 0.

Cat# LED High Bay

Cat# 71426A LED Wall-PACK QPL ID # PLO3JLI4OV69

Dark Sky Wallpack 50W. General ACD12 Aluminum Heat Sink High Light Transmittance Polycarbonate, Anti-UV and Fire Resistant Finish:

Dimming: PWM/TIME/0-5V/0-10V. RoHS

Morris Products 53 Carey Road, Queensbury, NY 12804


Photometric Test Report

DRAFT. Approved Method: Electrical and Photometric. Measurements of Solid-State Lighting Products. LCTECH (Zhongshan) Testing Service Co.

Transcription:

LM-79-08 Test Report for Elec-Tech International Co., Ltd No.1 Jinfeng Rd.,Tangjiawan Town, Xiangzhou District, Zhuhai City, Guangdong province, China BR40 LAMP Model: 525021XX(XX:01-10), WBR40L27S2A Laboratory: Leading Testing Laboratories NVLAP CODE: 200960-0 Tel: +86-571-56680806 www.ledtestlab.com The laboratory that conducted the testing detailed in this report has been accredited for SSL by NVLAP. Reviewed by: Approved by: Engineer: April Zou Oct. 24, 2013 Manager: Jim Zhang Oct. 24, 2013 Note: This report does not imply product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government.

U.S. Department of Energy Lighting Facts TM Uniform LM-79 Reporting Template Laboratory Information: Name of test Laboratory Leading Testing Laboratories Date of test Report Oct. 22~23, 2013 Test Report Number HZ13100023a Laboratory Contact Name Jim Zhang Product Information: Organization Name Elec-Tech International Co.,Ltd. Brand Name Whirlpool Model Number 525021XX(XX:01-10), WBR40L27S2A SKU (if available) N/A Type of Luminaire E26 base, BR40 LAMP (for integral lamps, list base type and lamp type) Luminaire Aperture (for Downlight) N/A in. Luminaire Length 6.12 in. Luminaire Width 4.61 in. Number of Units (modular products) N/A Electrical Measurements: Integrating sphere output Goniophotometer output Input Wattage 13.7 13.8 W Input Current 0.126 0.127 A Input Voltage ac 120.0 120.0 V Power Factor 0.9066 0.9056 Off-state Power 0 0 W Photometric Characteristics Total Initial Lumen Output 1014.0 1029.9 lm Initial Luminaire Efficacy 74.0 74.6 lm/w Correlated Color Temperature/ CCT 2659 K Color Rendering Index / CRI 83.0 R9 Value 25.9 Duv 0.0007 Luminous Intensity Distribution Center Beam Candlepower (if application) 308 cd Beam Angle (if application) 113.5 Zonal Lumens in the 0-60 Zone 66.71% Zonal Lumens in the 60-90 Zone 25.80% Zonal Lumens in the 90-120 Zone 6.25% Zonal Lumens in the 120-180 Zone 1.24% Prepared by: Leading Testing Laboratories Page 2 of 17

Test Summary Sample Tested: 525021XX(XX:01-10) Luminous Efficacy Total Luminous Flux Power (Lumens /Watt) (Lumens) (Watts) Power Factor 74.0 1014.0 13.7 0.9066 CCT Stabilization Time CRI (K) (Light & Power) 2659 83.0 60 Table 1: Executive Data Summary Note: The above results are recorded/ derived from measurements made using an Integrating Sphere. Test specifications: Date of Receipt : Oct. 21, 2013 Date of Test : Oct. 23, 2013 Test item : Total Luminous Flux, Luminous Distribution Intensity, Luminous Efficacy, Correlated Color Temperature, Color Rendering Index, Chromaticity Coordinate, Electrical parameters Reference Standard : IESNA LM-79-2008 Approved Method for the Electrical and Photometric Measurements of Solid-State Lighting Products CIE 13.3-1995 Method of Measuring and Specifying Color Rendering Properties of Light Sources CIE 15-2004 Technical Report Colorimetry IESNA LM-16-93 Practical Guide to Colorimetry of Light Sources IESNA TM-16-05 Technical Memorandum on Light Emitting Diode (LED) Sources and Systems Prepared by: Leading Testing Laboratories Page 3 of 17

TABLE OF CONTENT LM-79-08 Test Report... 1 Lighting Facts TM Uniform LM-79 Reporting Template... 2 Test Summary... 3 Sample Photos... 5 TEST RESULTS... 6 Spectral Power Distribution - Sphere Spectroradiometer Method... 7 Chromaticity Diagram - Sphere Spectroradiometer Method... 8 Nominal CCT Quadrangles Sphere Spectroradiometer Method... 9 Zonal Lumen Tabulation- Goniophotometer Method...10 Illuminance Plots- Goniophotometer Method...11 Luminous Intensity Distribution Plots- Goniophotometer Method...12 Luminous Intensity Data- Goniophotometer Method...13 EQUIPMENT LIST...15 TEST METHODS...15 Seasoning of SSL Product...15 Sphere-Spectroradiometer Method- Photometric and Electrical Measurements...15 Goniophotometer Method...16 Photometric and Electrical Measurements...16 Color Characteristics Measurements...16 Color Spatial Uniformity...16 Prepared by: Leading Testing Laboratories Page 4 of 17

Sample Photos Figure 1- Overview of the sample Equipment Under Test (EUT) Name Model Electrical Ratings Product Description Manufacturer Address Manufacturer (Alternative) Address : BR40 LAMP : 525021XX(XX:01-10) : 120V AC, 60Hz, 14W : E26 base, 2700K Quantity of light source: 28 pcs : Elec-Tech International Co., Ltd : No.18-1, Keji 6th Road, Gangwan Avenue, Tangjiawan Town, Xiangzhou District, Zhuhai City, Guangdong Province, P.R.China : Wuhu 3E Lighting Co., Ltd : No11.wei Rd.East Zone of wuhu Economice and Technological Development Area, Wuhu City Anhui Province, P. R. China Model difference description: For model 525021XX (XX:01-10), XX indicate for different packages, different costumer No. and different painting color of metal enclosure. Model WBR40L27S2A is identical with model 525021XX(XX:01-10). Prepared by: Leading Testing Laboratories Page 5 of 17

TEST RESULTS Test ambient temperature was 24.8. Test orientation was Base up. Test was conducted without a dimmer in the circuit. The stabilization time of the sample was 60 minutes, and the total operating time including stabilization was 95 minutes. Sphere-Spectroradiometer Method Parameter Result Special Color Rendering Indices Test Voltage (V) 120.0 R1 81.6 Voltage frequency (Hz) 60 R2 88.9 Test Current (A) 0.126 R3 94.9 Power Factor 0.9066 R4 81.1 Test Power (W) 13.7 R5 80.0 THD A% 40.39 R6 84.6 Luminous Efficacy (lm/w) 74.0 R7 86.9 Total Luminous Flux (lm) 1014.0 R8 66.8 Color Rendering Index (CRI) 83.0 R9 25.9 R9 25.9 R10 73.3 Correlated Color Temperature (CCT) (K) 2659 R11 78.1 Chromaticity (Chroma x, Chroma y) (0.4643, 0.4135) R12 65.7 Chromaticity (Chroma u, Chroma v) (0.2641, 0.3527) R13 82.7 Chromaticity (Chroma u, Chroma v ) (0.2641, 0.5291) R14 96.2 Duv 0.0007 Table: Test data per Sphere-Spectroradiometer Method Note: According to CIE 1976 (u',v') diagram, u' = u = 4x/(-2x+12y+3), v' = 3v/2 = 9y/(-2x+12y+3). Goniophotometer Method The photometric distance is 2.475m. Luminous data was taken at 0.5 vertical intervals and 10 horizontal intervals. Parameter Result Test Voltage (V) 120.0 Voltage frequency (Hz) 60 Test Current (A) 0.127 Power Factor 0.9056 Test Power (W) 13.8 Luminous Efficacy (lm/w) 74.6 Total Luminous Flux (lm) 1029.9 Beam Angle ( ) 113.5 Center Beam Candle Power (cd) 308 Spacing Criteria 1.25 (0-180 )/ 1.24(90-270 ) Table 2: Test data per Goniophotometer Method Prepared by: Leading Testing Laboratories Page 6 of 17

Spectral Power Distribution - Sphere Spectroradiometer Method Chart 1: Spectral Power Distribution Spectral Distribution over Visible Wavelength WL(nm) Radiant(Watts) WL(nm) Radiant(Watts) WL(nm) Radiant(Watts) WL(nm) Radiant(Watts) 380 6.75E-05 485 2.61E-03 590 1.93E-02 695 7.13E-03 385 6.79E-05 490 2.97E-03 595 2.00E-02 700 6.26E-03 390 7.15E-05 495 3.60E-03 600 2.05E-02 705 5.50E-03 395 6.70E-05 500 4.48E-03 605 2.09E-02 710 4.80E-03 400 9.22E-05 505 5.47E-03 610 2.12E-02 715 4.19E-03 405 1.04E-04 510 6.45E-03 615 2.12E-02 720 3.65E-03 410 1.69E-04 515 7.45E-03 620 2.10E-02 725 3.19E-03 415 3.22E-04 520 8.34E-03 625 2.07E-02 730 2.75E-03 420 6.55E-04 525 9.16E-03 630 2.02E-02 735 2.38E-03 425 1.16E-03 530 9.96E-03 635 1.95E-02 740 2.03E-03 430 1.92E-03 535 1.07E-02 640 1.87E-02 745 1.75E-03 435 2.87E-03 540 1.14E-02 645 1.78E-02 750 1.51E-03 440 4.21E-03 545 1.22E-02 650 1.69E-02 755 1.30E-03 445 6.17E-03 550 1.29E-02 655 1.58E-02 760 1.12E-03 450 7.55E-03 555 1.38E-02 660 1.46E-02 765 9.66E-04 455 6.74E-03 560 1.45E-02 665 1.35E-02 770 8.23E-04 460 5.10E-03 565 1.53E-02 670 1.23E-02 775 7.08E-04 465 4.08E-03 570 1.61E-02 675 1.12E-02 780 6.09E-04 470 3.30E-03 575 1.69E-02 680 1.01E-02 475 2.75E-03 580 1.78E-02 685 9.01E-03 480 2.50E-03 585 1.85E-02 690 8.03E-03 Table 3: Spectral Power Distribution Numerical Data per Sphere - Spectroradiometer Method Prepared by: Leading Testing Laboratories Page 7 of 17

Chromaticity Diagram - Sphere Spectroradiometer Method Tristimulus values(x, y) : (0.4643, 0.4135) Chart 2: Chromaticity Diagram per Sphere - Spectroradiometer Method Note: The location on the diagram of the tristimulus coordinates are indicated by the blue diamond. Prepared by: Leading Testing Laboratories Page 8 of 17

Nominal CCT Quadrangles Sphere Spectroradiometer Method Chart 3: Plot of Lamp x/y coordinates on CIE 1931 Chromaticity Diagram Prepared by: Leading Testing Laboratories Page 9 of 17

Zonal Lumen Tabulation- Goniophotometer Method γ( ) Lumens % Total 0-10 29.082 2.82% 10-20 83.035 8.06% 20-30 125.105 12.15% 30-40 149.948 14.56% 40-50 155.688 15.12% 50-60 144.175 14.00% 60-70 119.723 11.62% 70-80 88.385 8.58% 80-90 57.649 5.60% 90-100 33.671 3.27% 100-110 19.301 1.87% 110-120 11.402 1.11% 120-130 6.625 0.64% 130-140 3.59 0.35% 140-150 1.705 0.17% 150-160 0.643 0.06% 160-170 0.158 0.02% 170-180 0.016 0.00% Total 1029.9 100% γ( ) Lumens % Total 0-60 687.033 66.71% 60-90 265.757 25.80% 0-90 952.79 92.51% 90-180 77.111 7.49% 0-180 1029.9 100% Table 4: Zonal Lumen Data Prepared by: Leading Testing Laboratories Page 10 of 17

Illuminance Plots- Goniophotometer Method Chart 4: Beam angle Chart 5: Illuminance Plot (Footcandles) Prepared by: Leading Testing Laboratories Page 11 of 17

Luminous Intensity Distribution Plots- Goniophotometer Method Chart 6: Isocandela Plot Chart 7: Polar Candela Distribution Prepared by: Leading Testing Laboratories Page 12 of 17

Luminous Intensity Data- Goniophotometer Method Table 5: Luminous Intensity Data Prepared by: Leading Testing Laboratories Page 13 of 17

Table 6: Luminous Intensity Data Prepared by: Leading Testing Laboratories Page 14 of 17

EQUIPMENT LIST Test Equipment Model Equipment No. Calibration Date Calibration Due date Goniophotometer system GO-R5000 HZTE011-01 Sep. 18, 2013 Sep. 17, 2014 Digital Power Meter PF2010A HZTE028-01 Sep. 18, 2013 Sep. 17, 2014 AC Power Supply PCR 500L HZTE001-08 Sep. 18, 2013 Sep. 17, 2014 DC Power Supply WY12010 HZTE004-03 Sep. 18, 2013 Sep. 17, 2014 Temperature Meter TES1310 HZTE017-01 Sep. 18, 2013 Sep. 17, 2014 Standard source D908 HZTE012-01 Sep. 18, 2013 Sep. 17, 2014 Integrate Sphere system 2M HZTE015-01 Sep. 18, 2013 Sep. 17, 2014 Digital Power Meter WT210 HZTE008-01 Sep. 18, 2013 Sep. 17, 2014 AC Power Supply PCR 500L HZTE001-07 Sep. 18, 2013 Sep. 17, 2014 DC Power Supply 6154 HZTE004-04 Sep. 18, 2013 Sep. 17, 2014 Temperature and humidity recorder JR900 HZTE018-01 Sep. 18, 2013 Sep. 17, 2014 Standard source SCL-1400 HZTE012-02 Sep. 18, 2013 Sep. 17, 2014 TEST METHODS Table 7: Test Equipment List Seasoning of SSL Product For the purpose of rating new SSL products, SSL products shall be tested with no seasoning. Therefore, no seasoning was performed. Sphere-Spectroradiometer Method- Photometric and Electrical Measurements A Labsphere Model CDS 2100 Spectroradiometer and Two Meter Sphere was used to measure correlated color temperature, chromaticity coordinates, and the color rendering index for each SSL unit. The coating reflectance of each sphere is 98%. The measure geometry is 4π. Self-absorption correction is conducted in testing. Bandwidth of spectroradiometer is 350nm-1050nm. Ambient temperature was measured at a position inside the sphere. Each SSL unit was operated on the client provided driver at the rated input voltage in its designated orientation. The stabilization time typically ranges from 30 min (small integrated LED lamps) to 2 or more hours for large SSL luminaires). It can be judged that stability is reached when the variation (maximum minimum) of at least 3 readings of the light output and electrical power over a period of 30 min, taken 15 minutes apart, is less than 0.5 %. Electrical measurements including voltage, current, and power were measured using the Yokogawa Power Analyzer. The standard reference of the integrated sphere system is halogen incandescent lamp, the intensity distribution type is omni-directional, and is traceable to the National Institute of Standards and Technology. The uncertainty of integrating sphere system reported in this document is expended uncertainty is 1.06% with a coverage factor k=2. Prepared by: Leading Testing Laboratories Page 15 of 17

Goniophotometer Method Photometric and Electrical Measurements An EVERFINE Type C Model GO-R5000 Goniophotometer was used to measure the intensity at each angle of distribution for each sample. The photometric distance is 2.475m for near-field measurement or 30m for far-field measurement. Bandwidth of spectroradiometer is 380nm-780nm. Ambient temperature was measured at the same height of the sample mounted on the Goniophotometer equipment. Each SSL unit was operated on the client provided driver at the rated input voltage in its designated orientation. The stabilization time typically ranges from 30 min (small integrated LED lamps) to 2 or more hours for large SSL luminaires). It can be judged that stability is reached when the variation (maximum minimum) of at least 3 readings of the light output and electrical power over a period of 30 min, taken 15 minutes apart, is less than 0.5 %. Electrical measurements including voltage, current, and power were measured using the Everfine Digital Power Meter. Some graphics were created with Photometric Plus software. The standard reference of the Goniophotometer system is halogen incandescent lamp, the intensity distribution type is omni-directional, and is traceable to the National Institute of Metrology P.R. China. The uncertainty of goniophotometer system reported in this document is expended uncertainty is 1.94% with a coverage factor k=2. Color Characteristics Measurements The color characteristics of SSL products include chromaticity coordinates, correlated color temperature, and color rendering index. These characteristics of SSL products may be spatially non-uniform, and thus, in order that they can be specified accurately, the color quantities shall be measured as values that are spatially average, weighted to intensity, over the angular range where light is intentionally emitted from the SSL product. The color characteristics measurements are using gonio-spectroradiometer. Color Spatial Uniformity The characteristics of SSL products may be spatially non-uniform, the chromaticity coordinate shall be measured at two vertical planes (C=0 /180 and C=90 /270 ) and at 10 or less intervals for vertical angle until the light output dropped to below 10% of the peak intensity. The averaged weighted chromaticity coordinate was calculated from these points. The data was then analyzed to check for delta color differences of the u', v' chromaticity coordinates. The spatial non-uniformity of chromaticity, u'v', is determined as the maximum deviation (distance on the CIE (u', v') diagram) among all measured points from the spatially averaged chromaticity coordinate. The geometry for the chromaticity measurement using gonio-spectroradiometer is shown as following. Prepared by: Leading Testing Laboratories Page 16 of 17

*** End of Report *** This report is considered invalidated without the Special Seal for Inspection of the LTL. This report shall not be altered, increased or deleted. The results shown in this test report refer only to the sample(s) tested. Without written approval of LTL, this test report shall not be copied except in full and published as advertisement. Prepared by: Leading Testing Laboratories Page 17 of 17