Rapid Non linear Image Scanning Microscopy, Supplementary Notes

Similar documents
Nature Methods: doi: /nmeth Supplementary Figure 1. Schematic of 2P-ISIM AO optical setup.

Point Spread Function. Confocal Laser Scanning Microscopy. Confocal Aperture. Optical aberrations. Alternative Scanning Microscopy

Nature Neuroscience: doi: /nn Supplementary Figure 1. Optimized Bessel foci for in vivo volume imaging.

3D light microscopy techniques

Why and How? Daniel Gitler Dept. of Physiology Ben-Gurion University of the Negev. Microscopy course, Michmoret Dec 2005

Kit for building your own THz Time-Domain Spectrometer

Multicolor 4D Fluorescence Microscopy using Ultrathin Bessel Light sheets

The DCS-120 Confocal Scanning FLIM System

Instant super-resolution imaging in live cells and embryos via analog image processing

Characteristics of point-focus Simultaneous Spatial and temporal Focusing (SSTF) as a two-photon excited fluorescence microscopy

BASICS OF CONFOCAL IMAGING (PART I)

Supplementary Figure S1. Schematic representation of different functionalities that could be

Leica TCS SP8 Quick Start Guide

Supplemental Figure 1: Histogram of 63x Objective Lens z axis Calculated Resolutions. Results from the MetroloJ z axis fits for 5 beads from each

Confocal Imaging Through Scattering Media with a Volume Holographic Filter

Resolution. [from the New Merriam-Webster Dictionary, 1989 ed.]:

Nikon. King s College London. Imaging Centre. N-SIM guide NIKON IMAGING KING S COLLEGE LONDON

Flatness of Dichroic Beamsplitters Affects Focus and Image Quality

Be aware that there is no universal notation for the various quantities.

Leica TCS SP8 Quick Start Guide

3. are adherent cells (ie. cells in suspension are too far away from the coverslip)

Information & Instructions

a) How big will that physical image of the cells be your camera sensor?

Training Guide for Leica SP8 Confocal/Multiphoton Microscope

Enhancement of the lateral resolution and the image quality in a line-scanning tomographic optical microscope

Examination, TEN1, in courses SK2500/SK2501, Physics of Biomedical Microscopy,

Supplementary Materials

12.4 Alignment and Manufacturing Tolerances for Segmented Telescopes

Determination of the Focal Width with the Focal Width Script

More fancy SPIM, Even fancier SPIM

plasmonic nanoblock pair

Supplementary Information. Stochastic Optical Reconstruction Microscopy Imaging of Microtubule Arrays in Intact Arabidopsis thaliana Seedling Roots

Nikon Instruments Europe

Fast, high-contrast imaging of animal development with scanned light sheet based structured-illumination microscopy

3D light microscopy techniques

High resolution extended depth of field microscopy using wavefront coding

Fiber Optic Communications

1 Co Localization and Working flow with the lsm700

Presented by Jerry Hubbell Lake of the Woods Observatory (MPC I24) President, Rappahannock Astronomy Club

Practical work no. 3: Confocal Live Cell Microscopy

Nature Structural & Molecular Biology: doi: /nsmb Supplementary Figure 1

Εισαγωγική στην Οπτική Απεικόνιση

Optical coherence tomography

Practical Flatness Tech Note

Supplementary Information for. Surface Waves. Angelo Angelini, Elsie Barakat, Peter Munzert, Luca Boarino, Natascia De Leo,

Development of a High-speed Super-resolution Confocal Scanner

Shreyash Tandon M.S. III Year

Adaptive optimisation of illumination beam profiles in fluorescence microscopy

11Beamage-3. CMOS Beam Profiling Cameras

SETTING UP OF A TOTAL INTERNAL REFLECTION FLUORESCENT MICROSCOPE (TIRFM) SYSTEM: A DETAILED OVERVIEW

Supplementary information, Figure S1A-S1H The thickness and the uniformity of the light sheet at different DOFs. By

TSBB09 Image Sensors 2018-HT2. Image Formation Part 1

Dynamic beam shaping with programmable diffractive optics

Optical Sectioning Deep Inside Live Embryos by Selective Plane Illumination Microscopy

SUPPLEMENTARY INFORMATION

Zeiss 880 Training Notes Zen 2.3

ANSWER KEY Lab 2 (IGB): Bright Field and Fluorescence Optical Microscopy and Sectioning

Instruction manual for T3DS software. Tool for THz Time-Domain Spectroscopy. Release 4.0

Chapter 18 Optical Elements

1 Set up the confocal light path for imaging a green dye (Alexa488-EGFP). For example, the

An Optical Characteristic Testing System for the Infrared Fiber in a Transmission Bandwidth 9-11μm

Heisenberg) relation applied to space and transverse wavevector

Deep and fast live imaging with two-photon scanned light-sheet microscopy

Basics of confocal imaging (part I)

880 Quantum Electronics Optional Lab Construct A Pulsed Dye Laser

Supporting Information

The Zeiss AiryScan System, Confocal Four.

Akinori Mitani and Geoff Weiner BGGN 266 Spring 2013 Non-linear optics final report. Introduction and Background

Fundamentals of Light Microscopy II: Fluorescence, Deconvolution, Confocal, Multiphoton, Spectral microscopy. Integrated Microscopy Course

Sizing of nano structures below the diffraction limit using laser scanning microscopy

High-Resolution Bubble Printing of Quantum Dots

ECEN 4606, UNDERGRADUATE OPTICS LAB

AgilOptics mirrors increase coupling efficiency into a 4 µm diameter fiber by 750%.

Lab Report 3: Speckle Interferometry LIN PEI-YING, BAIG JOVERIA

BEAMAGE-3.0 KEY FEATURES BEAM DIAGNOSTICS AVAILABLE MODELS MAIN FUNCTIONS SEE ALSO ACCESSORIES. CMOS Beam Profiling Cameras

Rates of excitation, emission, ISC

D2.1 Operating 2D STED Microscope

ECEN. Spectroscopy. Lab 8. copy. constituents HOMEWORK PR. Figure. 1. Layout of. of the

Reflecting optical system to increase signal intensity. in confocal microscopy

Zeiss LSM 780 Protocol

Instructions for the Experiment

Transferring wavefront measurements to ablation profiles. Michael Mrochen PhD Swiss Federal Institut of Technology, Zurich IROC Zurich

Properties of Structured Light

Single-photon excitation of morphology dependent resonance

Imaging Retreat - UMASS Customized real-time confocal and 2-photon imaging

Supporting Information

ERS KEY FEATURES BEAM DIAGNOSTICS MAIN FUNCTIONS AVAILABLE MODEL. CMOS Beam Profiling Camera. 1 USB 3.0 for the Fastest Transfer Rates

ASD and Speckle Interferometry. Dave Rowe, CTO, PlaneWave Instruments

Fluorescence Imaging of Single Spins in Nitrogen-Vacancy centers using a Confocal Microscope. Advanced Lab Course University of Basel

User manual for Olympus SD-OSR spinning disk confocal microscope

Imaging Beyond the Basics: Optimizing Settings on the Leica SP8 Confocal

Tutorial Zemax 9: Physical optical modelling I

Bi/BE 227 Winter Assignment #3. Adding the third dimension: 3D Confocal Imaging

Exercise questions for Machine vision

Optomechanical enhancement of doubly resonant 2D optical nonlinearity

Introduction to Light Microscopy. (Image: T. Wittman, Scripps)

Spectral phase shaping for high resolution CARS spectroscopy around 3000 cm 1

Rapid Adaptive Optical Recovery of Optimal Resolution over Large Volumes

BEAMAGE KEY FEATURES AVAILABLE MODELS. CMOS Beam Profiling Cameras

Coherent Laser Measurement and Control Beam Diagnostics

Transcription:

Rapid Non linear Image Scanning Microscopy, Supplementary Notes Calculation of theoretical PSFs We calculated the electrical field distribution using the wave optical theory developed by Wolf 1, and Richards and Wolf 2, for imaging through optical systems with high numerical aperture. From the obtained field we calculated the intensity,, and the squared intensity,,. To describe the PSF we use the FWHM diameters of,, along and perpendicular to the z axis along which the light propagates. We approximated the incident laser beam at the back focal aperture of the objective by a Gaussian beam and calculated the extensions of the PSFs for back focal beam radii ranging from 2 mm to 4 mm. The values of the other parameters used were: numerical aperture NA 1.3; refractive index of immersion medium equal to 1.41; excitation wavelength 900 nm. Figure S1: (a) 3D representation of the 2PE PSF as an isosurface corresponding to ½ of its maximum value. (b) axial (+) and lateral (o) diameters (FWHM) of the 2PE PSF and their dependence on the beam diameter in the back focal aperture of the objective. 1. Wolf, E. Electromagnetic diffration in optical systems 1. An integral representation of the image field. Proceedings of the Royal Society, 349 357 (1959). 2. Richards, B. & Wolf, E. Electromagnetic diffraction in optical systems 2: Structure of the image field in an aplanatic system. Proceedings of the Royal Society, 358 379 (1959).

Rendered images of 3D SHG signals Figure S2 shows different views of a 3D stack of the SHG signal of a collagen I hydrogel as described in the online methods. Figure S2: 3D representations of conventional microscopy (a,c) and de convolved SHG ISM (b,d). (a) and (b) show pseudo colored z stacks; (c) and (d) show maximum intensity volumetric renderings. Image size: 63.5 µm x 29.5 µm.

Beam path in the ISM microscope The use of a galvo scanner with a resonant and a conventional scan axis has some implications to the beam path that are not obvious at first sight. The two mirrors create a lateral shift between the optical axis of the objective and the optical axis of the entrance port of the scanner. When feeding the emitted light back into the scanner, this shift needs to be compensated. The second implication is that the directions of the movement of the beam has to be matched when feeding the beam back to the scanner. This is illustrated in figure S3. There, the movement, generated by the first scan mirror (SM1) is upwards, as indicated by the green arrow on top of the beam. For the emitted beam (shown in blue) this movement is identical and if it was simply reflected upwards, the movement does not match the motion of SM1. Hence, in order to obtain a doubling of the scan angle, one needs to rotate and invert the beam in combination with the necessary lateral shift. In our setup this is achieved by a combination of three mirrors (M1 to M3). Figure S3: Schematic view of the beam path in the ISM microscope. For simplicity, the scan and tube lenses are not shown. The excitation light is shown in red, light

emitted by the sample is shown in blue. Sections where excitation and fluorescence overlap are shown in green. The arrows indicate the beam deflection due to movement of the resonant scan mirror (green) and the second scan mirror (red). The excitation beam enters the setup and is reflected by the dichroic mirror (DCM3) onto the optical axis of the scanner. The beam is scanned via the resonant scan mirror (SM1) and the second scan mirror (SM2). It propagates through the dichroic mirror (DCM1) and is reflected by the dichroic mirror (DCM2) into the microscope objective. The emitted light is collected by the objective, passes DCM2 and is reflected by a mirror to the arrangement of three mirrors (M1 M3). These mirrors align the beam with the axes of the scanner. Then, the beam passes DCM3 and is re scanned via SM1 and SM2. Finally, the light is coupled out by DCM1 and imaged onto a camera (not shown).

Image data processing Processing of the recorded imaging data is done according to the following steps: 1. Background subtraction. A background dataset consisting of 100 frames is recorded using the same settings as for the image recording, but without excitation. The frames are averaged and smoothed with a Gaussian filter. The resultant representation is then subtracted from the image data. Negative results are clipped to zero. It is also possible to simply subtract an average value taken from unexposed areas of the camera sensor if the background data is not available. 2. Removal of pixel artifacts. To remove artifacts from hot or cold pixels we proceed as follows. For each pixel we calculate the expected value E by linear interpolation for its surrounding pixels. We also compute the local variance based on the interpolation for the surrounding pixels. If the pixel value exceeds the range 3 we consider this as an artifact and set this pixel to the value of E. If one uses ImageJ one can use the Remove outliers function using a threshold based on the variance of the histogram of the image data. 3. Final processing. After an optional Fourier reweighting, the data is filtered using a 2D Gaussian filter with a radius of 1 pixel (about 46 nm) and, usually, 2x2 pixels are binned. Finally, the 16 bit data is downscaled to 8 bit dynamic range.

Fourier reweighting 1. The first aim is to compute the Fourier transform F(k) of the image data. To minimize problems by boundary effects, we pad the original data using accordingly flipped patches from each respective border. The aim is to obtain an image of the size N x N, where log ceil max, 1, and a, b denote the size of the image. 2. Additionally, we let the intensity of the synthesized image decay toward the borders using a linear ramp that falls from 1 to 0 in the range R = N/2 to R = N. 3. Next, we do the Fourier transform of the conditioned data. We separate the modulus and the phase angle of the FT data, since we only want to re weigh the modulus. The modulus can take values different from 0 only for max where max is the maximal length of a k vector that is transmitted by the objective: max 4 NA/ em. This, for all max F(k) has to be 0. 4. The ideal MTF curve of a microscope would be fi 2/π acos 1 with ma. Since the imaging process in ISM delivers a MTF that is basically raw fi one could use a weight function 1 fi to recover fi from raw. Since the fi has low amplitudes for 1 this would mean high values of and thus amplifying noise. Therefore one has to use a regularization avoiding this. A simple approach is 1 fi where takes reasonably small values. Typically 0.02 works well, but this depends on the SNR. 5. After applying the corrections on F(k) one can back transform the data into real space. 6. A MatLab script showing this procedure on sample data is shown below. 7. Since the ISM raw images already contain the expanded frequency support, one can also achieve the resolution enhancement using so called deconvolution algorithms, e.g. Richardson Lucy deconvolution. Classical deconvolution is not able to gain resolution improvements but sharpens blurring by trying to de convolve image data with the PSF. This essentially is the same operation that one implicitly does when reweighting the amplitudes in the MTF. Therefore, these algorithms can be applied in ISM, too.

An exemplary MatLab script showing the steps of this procedure: % read data from file name = 'actin.tif'; data = double(imread(name,'tiff')); data = max(data,0); % clip negative values [nx,ny] = size(data); N = 2^ceil(log2(max(nx,ny))+1); % size of image for Fourier transform % stich patches of the original image to form a periodic 'super-image' im = [data fliplr(data) data fliplr(data) data]; im = [flipud(im); im; flipud(im); im; flipud(im); im; flipud(im)]; % cut out the center part of the 'super-image' of size NxX [sx,sy] = size(im); im = im(floor((sx-n)/2)+(1:n),floor((sy-n)/2)+(1:n)); % let the signal decay to zero towards the edges [X,Y] = meshgrid(1:n,1:n); X = (X-N/2-1); Y = (Y-N/2-1); R = sqrt(x.^2+y.^2); W = 2-8*R/N; W = min(w,1); W = max(w,0); im = W.*im; % Do the Fourier transform fim = fftshift(fft2(im)); fa = abs(fim); % modulus fp = angle(fim); % Phase angle % calculate k-vectors of the Fourier-transformed image fs = 1/0.091; % per µm k = fs/2/(n/2).*r; km = 5.5; ind = double(k<km); % Step function to clip everything outside km to zero % 'Ideal' MFT OTF = ind.*2/pi.*(acos(k./km)-k./km.*sqrt(1-(k./km).^2)); % Re-weighting function ep = 0.015; w = ind./(otf + ep.*k./km); % Back-transform the re-weighted FT tim = abs(ifft2(ifftshift(w.*fa.*exp(1i.*fp)))); % cut out the original field of the data tim = tim((n-nx)/2+(1:nx),(n-ny)/2+(1:ny)); % display original data vs. re-weighted data imagesc([data; tim]) colormap(gray(256)) caxis([0 350]) axis image axis off

Description of Additional Files and Videos SupplementaryVideo 1.mov : This is a rendering of a collagen I gel as described in the paper. The data was recorded done using a conventional SHG confocal microscope. SupplementaryVideo 2.mov : This is a rendering of the same sample as in SHG.mp4. In this case the data was recorded using the ISM confocal microscope. SupplementaryVideo 3.mov : This video shows fluorescent beads (d = 100 nm) diffusing freely in water. The recording frame rate is 20 fps. The acquisition speed is sufficient to track individual beads for several frames until they diffuse out of focus. SupplementaryVideo 4.mov, SupplementaryVideo 5.mov, SupplementaryVideo 6.mov, and SupplementaryVideo 7.mov are rendered video sequences time series of 3D stacks of living Drosophila embryos as described in the Online Methods. The frame interval is 60 s or 120 s in the case of SupplementaryVideo 7.mov. Spacing of the z planes is 3 µm. The sections are taken around the center height of the embryo.