Incandescent Lampholders: Edison Screw and Bayonet Cap

Similar documents
Medium-base Lampholders

DIK 1,5 General data Technical data General

High-current terminal block - UKH

Data sheet. W-Series WDU 2.5

Data sheet... W-Series WDU 2.5

Data sheet. W-Series WDU 2.5 RT

Feed-through terminal block - PT 10-TWIN

MKDS 3/ 4. Extract from the online catalog. Order No.:

Datenblatt. W-Series WDU 2.5

SMKDSP 1,5/ 8. Extract from the online catalog. Order No.:

Data sheet. W-Series WDU 10

Data sheet. W-Series WDU 4 BL

General data. Technical data DIKD 1,5. General. Dimensions

Through and Ground Conductor Terminal Blocks 290 Series

MKDSN 1,5/ 4-5,08. Extract from the online catalog. Order No.:

SMKDS 2,5/ 2-5,08. Extract from the online catalog. Order No.:

VARIOCON. Modular Contact Inserts

HARTING Han-Power T Solutions

Subject to changes 11/2003 Page 1/7

MKKDSH 3/ 2. Extract from the online catalog. Order No.:

Datenblatt. W-Series WDU 10

Switching power supplies CP range, Linear power supplies CP-L range. Content

FRONT 2,5-H/SA 5. Extract from the online catalog. Order No.:

Rectangular Industrial Connectors: Technical Data Overview EPIC HBE SERIES

LED Driver Constant voltage

UTTB 4. Extract from the online catalog. Order No.:

LF SERIES CLASS R & H/K5 FUSE BLOCKS

Datasheet. W-series terminal with clamping yoke connection WDU 16

UTTB 2,5. Extract from the online catalog. Order No.:

KDSP 4. Extract from the online catalog. Order No.:

MCR-SL-CUC Universal current transducer. Data sheet _en_05. 1 Description

both pin and sleeve contacts.

Technical data. Contact material: with double break or 2 NC contacts Switching system: A IEC snap action with positive break NC contacts

DATASHEET - ETR4-70-A. Delivery program. Timing relay, 2W, 0.05s-100h, multi-function, VAC/DC, potentiometer connection

KDS10/SO. Extract from the online catalog. Order No.:

FieldLink MC at 20 x outer diameter Torsion

DATASHEET - ETR4-51-A. Delivery program. Technical data General. Timing relay, star-delta, 50 ms, 1W, 3-60s, VAC/DC

Copper Compression Lugs Conductor Size #8

Amphenol. Circular. Connectors C 16-1 / C Circular Connectors. Amphenol-Tuchel Electronics

Contents. Han Hv ES / Han Hv E Technical characteristics Han Hv ES Technical characteristics Han Hv E Han 3 Hv ES

MVSTBR 2,5/ 2-ST. Extract from the online catalog. Order No.:

MSTB 2,5/ 3-ST. Extract from the online catalog. Order No.:

Catalog 200 Contactors up to 115 A Motor Starters up to 55 kw 03/2009

Motor-protective circuit-breaker, 3p, Ir=40-50A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A

Tools for crimp contacts

Pluggable connection describes the method used to connect an external conductor to a PCB, via a terminal connector and header

HARTING Han GND. People Power Partnership

MSTB 2,5/ 4-ST. Extract from the online catalog. Order No.:

General characteristics and technical data Series VarioPro Basic

Success Depends on the Crimp

MC 1,5/ 4-ST-3,5. Extract from the online catalog. Order No.:

LED Driver Constant voltage

MVSTBW 2,5/ 5-ST. Extract from the online catalog. Order No.:

08/07/2015

SLKK 5. Extract from the online catalog. Order No.:

Electronic timer CT-AWS Impulse-OFF with 1 c/o contact Data sheet

ELECTRICAL INSTALLATION PRODUCTS Splicing Connectors and Chassis Mount Terminal Blocks

CABLES FOR MOTION CONTINUOUS-BENDING HI-FLEX ELECTRICAL CABLES TOTALTRAX TURN-KEY SYSTEMS PRE-ASSEMBLED CABLES STRAIN RELIEF DEVICES

Type CP-S, CP-C & CP-A Switch mode

RESISTRON RV Operating Instructions. 1 Technical data

Coupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC

KRPA, KRP, KA, KR series

STANDARD RTD's INDEX

Measuring current transformers of the W, W series

INTERMEDIATE METAL CONDUIT

Micro Contactors. Micro Contactor Relays 10. Micro Contactors 11. Micro Contactors With Solder Pins 12. Coil voltages 12. Micro Reversing Contactor 13

onlinecomponents.com

1.4 Section LAMPHOLDERS AND INLINE SWITCHES. Design. Scame by VLM

Measuring current transformers of the W AB(P) series

ENVIRONMENTAL. Operating Temperature: -40ºC to +125ºC. Insulator Color 9 = UL White 8 = UL Black Special Order

Electronic relays. Monitoring. Monitoring

Electronic timer CT-ERS ON-delayed with 2 c/o contacts Data sheet

SIGNAL // POWER // INDUSTRIAL ETHERNET

Operating tools. with partially insulated shaft Type 1, 2 and 3 in set

Magnetic Encoder MEM 22

POWER CAGE CLAMP High-Current Terminal Blocks for Conductors up to 350 kcmil (185 mm 2 )

General data. 13/20 Siemens IC Overview Front plate mounting

Power supply CP-D 24/4.2 Primary switch mode power supply

Optical encoder MEC22 HR

SE22 Mini Encoder Data Sheet 5V TTL power supply optical model

Series D 7 - D 128. Locking systems: Housings for series D 7, D 8, D 15, D 25 and D 128: only with single locking system

Assembly of Contacts 700-FS A 3 A U23. Function Contact Outputs Time Ranges Supply Voltages All functions: Z12 12V DC

Data sheet C6 A RJ45 field plug pro 360

Electronic timer CT-MVS.23 Multifunctional with 2 c/o (SPDT) contacts

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

Main catalogue. SNK Series Terminal Blocks Accessories Marking Solutions

PSD-S CE-TM SPRING. Connection element with spring-cage terminal blocks for tube mounting. Data sheet. 1 Description

Data sheet C6 A RJ45 field plug pro

Features. Applications. Plastic Housing. Sensor PCB Assembly. Plastic Hub. Plastic Base Plate. 2 x screws

Measuring current transformers of the W B series

HARAX. Contents Technical characteristics circular connector with HARAX rapid termination 50.02

Control Stations ø 22

WINSTA The Connection System. Full Line Catalog 2010/2011

Three-phase monitoring relays CM-PFE and CM-PFE.2

Data sheet C5 RJ45 field plug pro 2P PROFINET

Data sheet. M12 Jack X-coded IP67, field assembly. Illustrations P/N MMF881A315 EAN Product specification. Page 1/

No-wear isolation of potentials in terminal block design

Coupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC

We recommend using the locking levers on the firmly mountable wall mount housing or panel housing.

Circuit diagram. Applications. Function. Function (Continued) Page 23 SNO 4062K /K-A /KM /KM-A

Transcription:

: Edison Screw and Bayonet Cap

Table of Contents E14 22.223 22.230 E12 22.228 22.231 [08]..10 E17 E27 22.317 [08] 12 22.318 [08] 12, 13 2010-2012 This page is only valid in connection with the general information and notes of the complete catalog, issue 2010-2012 [08] 3

General Information All articles in this chapter have been designed according to UL and/or CSA or to the appropriate national and international standards (VDE / ). The choice of product and correct technical application is the sole responsibility of the user. Further information available on request. We reserve the right to modify products without notice. When regulations deviate from, e. g. UL, other ratings may be possible. Please also note the general information at the end of this catalog and the directions for use. Explanation of the symbols shown on the product pages. Temperature rating T 210 The maximum operating temperature is given by a T marking. This is the maximum operating temperature for which the lampholder is designed. Without T marking, the following ratings apply: 135 C for E14 / B15, 165 C for E27 / B22 Temperature rating / Temperature index according to UL Rating Indication of rated values. For PSE (Japan) approvals. Starting voltage (In this example 5 kv / pulse) Twin push wire terminals CAD-Data files in 2D or 3D format available For tinned wire ends within the cross sectional range stated (In this example 0.5-1.0 mm 2 ) When regulations deviate from, other cross sections are possible (i. e. UL / CSA: cable 18 AWG). Additional information Further information about the products shown on this page can be found on the pages shown within this symbol. 0.5-1.0 mm 2 [08]... max. ø 1.8 mm For wire ends with ferrule to the maximum diameter stated (In this example max. ø 1.8 mm) The cable and termination used must be compatible in respect of: Diameter and length of the ferrule. For further information see DIN 46228, part 3, size 1-7 For solid conductors within the cross sectional range stated (In this example 0.5-1.0 mm 2 ) When regulations deviate from, other cross sections are possible (i. e. UL / CSA: cable 18 AWG). 0.5-1.0 mm 2 Material thickness Indication in mm (In this example 0.6-1.0 mm) 0.6-1.0 mm Rating Indication of rated values. For culus (USA) approvals. Rating Indication of rated values. [08] 4 This page is only valid in connection with the general information and notes of the complete catalog, issue 2010-2012 2010-2012

Technical Information The information and values stated here are for quick reference only. For specific information please contact the relevant lamp manufacturer. Lamp base/ standard Lampholder/ standard Lampholders see page E12 E12 E12 60061-1 7004-28 60061-2 7005-28 E14 E14 E14 60061-1 7004-23 60061-2 7005-20 E17 E17 E17 60061-1 7004-26 60061-2 7005-20 E26 E26 E26 [08] 12, 13 60061-1 7004-21A 60061-2 7005-20 2010-2012 This page is only valid in connection with the general information and notes of the complete catalog, issue 2010-2012 [08] 5

Mounting Methods Lampholders E12, E14, E17 Mounting Method Lampholder Lampholders see page Metal sheet Push in fixing 22.228.3913 22.230 22.231 Plastic Push in fixing 22.228.3913 22.230 22.231 Plastic Push in fixing 22.228.3913 Metal sheet Snap in fixing into housing cut-out 22.230 22.231 * Gap only for use with lampholder E17-.3922.81 Plastic Snap in fixing into housing cut-out 22.230 22.231 * Gap only for use with lampholder E17-.3922.81 [08] 6 This page is only valid in connection with the general information and notes of the complete catalog, issue 2010-2012 2010-2012

Mounting Methods Lampholders E12, E14, E17 Mounting Method Lampholder Lampholders see page Metal sheet Bayonet fixing Plastic Bayonet fixing Screw fixing 22.223 22.228 Snap in fixing 22.223 22.228 2010-2012 This page is only valid in connection with the general information and notes of the complete catalog, issue 2010-2012 [08] 7

Mounting Methods Lampholders E26 Mounting Method Lampholder Lampholders see page Screw fixing 22.317 22.318 [08] 12 [08] 12, 13 Snap in fixing 22.317 22.318 [08] 12 [08] 12, 13 [08] 8 This page is only valid in connection with the general information and notes of the complete catalog, issue 2010-2012 2010-2012