TEST REPORT TEST REPORT. Report Number : ETLE Report issue date: May 26, Address : , Gongreung-dong, Nowon-gu, Seoul, Korea

Similar documents
EMC TEST REPORT CE TEST REPORT. for Audio / Video receivers and associated equipment

EMC TEST REPORT CE TEST REPORT. Report Number : ETLE Report issue date: August 21, 2009

FCC TEST REPORT. Table of Contents. Report no. ETLE , Page 2 of 21

FCC TEST REPORT. Table of Contents. FCC Measurement Report

EMC TEST REPORT. According to

Test Report for FCC FCC ID :TKWBEP2-OD

Test Report for FCC FCC ID :TKWFS2-AWB

EMI T E S T R E P O R T

TABLE OF CONTENTS 1. GENERAL DESCRIPTION OF EUT 3 2. GENERAL INFORMATION OF TEST CONDUCTED EMISSION TEST RADIATED EMISSION TEST 10

FCC TEST REPORT. Table of Contents. Report no. ETLE , Page 2 of 21

FCC TEST REPORT FCC ID: PFNDMS2344UHDW

CENTRE OF TESTING SERVICE INTERNATIONAL

IST EMC LAB. EMISSION TEST REPORT. : DSP-4284GM Basic Alternate. : PDP(Plasma Display Panel) : Daewoo Electronics Corp. : Daewoo Electronics Corp.

Declaration of Conformity.

TABLE OF CONTENTS. 1. General Description of EUT General Information of Test Conducted Emission Tests 7-10

TEST REPORT... 1 CONTENT...

TEST SUMMARY. Prüfbericht - Nr.: Test Report No.: Seite 2 von 27. Page 2 of 27

TEST SUMMARY. Prüfbericht - Nr.: Test Report No.: Seite 2 von 25. Page 2 of 25

FCC Part 15B Measurement and Test Report. For. GlobTek, Inc. 186 Veterans Dr. Northvale, NJ USA. FCC Part 15 Subpart B.

STC Test Report. The Hong Kong Standards and Testing Centre Ltd.

Test Report for Part 15

FCC PART MEASUREMENT AND TEST REPORT

FCC TEST REPORT FCC ID: PFNDMS-2344UHDS

TABLE OF CONTENTS. 1. General Description of EUT General Information of Test Conducted Emission Tests 7-12

EMI -- T E S T R E P O R T

Page 1 of 20 No.: HM TEST REPORT FCC PART 15 SUBPART C CERTIFICATION REPORT FOR LOW POWER TRANSMITTER. TEST REPORT No.

FCC PART 15, CLASS B MEASUREMENT AND TEST REPORT. NanJing JingZe Lighting Technology Co.,Ltd

TEST REPORT. : The submitted samples complied with the above EMC standards. TRF No.: AS NZS (2012)-b

TABLE OF CONTENTS. Report No.: SH E03 1. TEST RESULT CERTIFICATION...3

FCC Verification TEST REPORT

EMC Research Institute

EMI -- T E S T R E P O R T

FCC & RSS-216 (Class II Permissive Change) Wireless Power Transfer Report. for A Acer Incorporated

EMC TEST REPORT RADISYS CORPORATION. Tel: Fax:

Harmonic Current emission EN :2014 Class A Pass. Voltage Fluctuation and Flicker EN :2013 Clause 5 Pass

FCC EVALUATION REPORT FOR CERTIFICATION

Discontinuous Disturbance (Click) EN :2006+A1:2009+A2:2011 Clause N/A** Radiated Emission, 30MHz to 1000MHz

APPLICATION FOR CERTIFICATION On Behalf of Futaba Corporation Radio Control Model No.:T10CG-2.4G FCC ID:AZPT10CG-24G Brand : Futaba

TABLE OF CONTENTS 1. GENERAL DESCRIPTION OF EUT 3 2. GENERAL INFORMATION OF TEST CONDUCTED EMISSION TEST RADIATED EMISSION TEST 11

ELECTROMAGNETIC EMISSIONS COMPLIANCE REPORT

FCC 47 CFR PART 15 SUBPART B TEST REPORT SHENZHEN EAGLE TECHNOLOGY CO., LTD Mirror photo booth Model No.: EAGMR

REVISION HISTORY. The revision history for this document is shown in table. HCT-EM-1801-FC037 January 22, 2018 Initial Release

No. 620 HuaYuan Commercial Center, No. 347 XiXiang Road,XiXiang Town, Bao An District, ShenZhen City Tel : Fax:

KES. hereby. Dong Hun, Jang. Signature: Model: FCC Rule Part(s): 84, Jeongdong-r. Park KES-E1-15T0042 SNB-6011N. specified

FCC MEASUREMENT REPORT

STC Test Report. Date : Page 1 of 13 No. : HM161169

EMC TEST REPORT for Repel-it. REPEL-IT ULTRASONIC PEST REPELLER Model No. : REPEL-IT/UPR/AN-B019

EMISSION TEST REPORT

Report for Excelsys EMC Measurements for 6Xgen Purchase Order: by Project Number EMT08J027

King Pigeon Communication Co., Limited

FCC TEST REPORT On Behalf of GZTOD.CO., LTD The Multifunctional Platooninsert Model No.: YA30WSL-6AU6U

EMC VERIFICATION SUMMARY Report No.: SZHH

STC Test Report. Date: Page 2 of 25 No.: MH The Hong Kong Standards and Testing Centre Ltd.

EMC Test Report. Product. Model Number. Prepared for : Shenzhen top technology co., LTD Address : No 2.First Rd Of Lucky,Longgang Ping Shenzhen China

Global No.1 Testing Laboratory Universal Certification Solution FCC TEST REPORT ODROID-XU4. FCC CFR 47 PART 15 SUBPART B Section UCS Co., Ltd.

Contents. Report No.: EMC-FCC-1985 Page: 2 of 26

FCC 47 CFR PART 15 SUBPART B TEST REPORT KST DIGITAL TECHNOLOGY LIMITED. Brushless Servo

FCC MEASUREMENT REPORT

RADIO SPECTRUM TEST REPORT. BioStation Mifare TC(BSM-TC) Suprema Inc. ESTECH CO., LTD

FCC TEST REPORT. Table of Contents

Nemko Canada Inc., 303 River Road, R.R. 5, Ottawa, Ontario, Canada, K1V 1H2

Test Report: 5R Champlain Street Dieppe, New Brunswick Canada E1A 1P6. Model Number: Verification

FCC CERTIFICATION TEST REPORT

By order of ZHONGSHAN LIANGYI LIGHTING CO., LTD. at Zhongshan, China

FCC TEST REPORT. SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.

TABLE OF CONTENTS Page 1 of VERIFICATION OF CONFORMITY SYSTEM DESCRIPTION PRODUCT INFORMATION SUPPORT EQUIPMENT

TEST REPORT. Table of Contents

VCCI TEST REPORT. According to. Class B ITE. Equipment : USB video camera

EMI TEST REPORT. : FCC part 15 subpart B, Class B

EMI T E S T R E P O R T

Content. Report No. SH Page 2 of 22

Test Report: 4R Champlain Street Dieppe, New-Brunswick Canada E4P 8L6. Model Number: Verification

FCC CLASS B COMPLIANCE REPORT (DoC)

2. Description of EUT. 3. Test Standards. 4. Measurement condition. 5. Carrier Frequency Separation. 8.2 Test instruments and measurement setup

TEST REPORT FROM RADIO FREQUENCY INVESTIGATION LTD.

TEST REPORT. draft draft draft. TRF Originator...: Shenzhen CTL Testing Technology Co., Ltd. Master TRF...: Dated

Itron, Inc. TEST REPORT FOR. RF Telemetry Device Model: CCU100. Tested To The Following Standards:

ELECTROMAGNETIC EMISSION COMPLIANCE REPORT

ELECTRONICS TESTING CENTER(ETC), TAIWAN

Medtronic MiniMed TEST REPORT FOR. GST3 Glucose Sensor Transmitter, MMT-7763A. Tested To The Following Standards:

EMC Test report for LED Panel Light Models , , , , ,

AUSTRALIA TEST REPORT For. KLM Lighting Co., Limited. LED Down Light. Model No.: KLM-HP30WSN

VCCI TEST REPORT. According to. V-3/ , TECHNICAL REQUIREMENTS, Class B ITE. Equipment : USB video camera. Model No. : V-U0017 / V-U0021

BUREAU VERITAS. itaste svd

CENTRE OF TESTING SERVICE INTERNATIONAL

RF Emissions Test Report To Determine Compliance With: FCC, Part 15 Rules and Regulations

EMC Testing Report. Dual-120CS. Yuan Hsun Electric Co., Ltd.

FCC Part 15 Subpart B

EMI TEST REPORT : SAMSUNG ELECTRONICS CO., LTD.

FCC REPORT. 2AKQO-Q740 FCC CFR Title 47 Part 15 Subpart C. * In the configuration tested, the EUT complied with the standards specified above.

TEST REPORT. Building 6, XinXinTian Industrial Park, XinSha Road, ShaJing, Baoan District, ShenZhen, China. Shenzhen Innokin Technology Co.

APPLICATION FOR VERIFICATION On Behalf of Carewell Electric Technology (Zhongshan) Co., Ltd. REMOTE CONTROL Model No.: AC8 FCC ID: 2AAZPAC8

Electromagnetic Compatibility Test Report FCC test results of an automatic dog brush, model EUT: Type 1 AC/DC adaptor: SYS W2E

5.3 TEST SETUP AND PROCEDURE TEST DATA MEASUREMENT UNCERTAINTY FLICKER USED TEST EQUIPMENT...18

FCC TEST REPORT On Behalf of. Global Tech China Limited. Solar Light(Large)/28W,16W. Model No.: Additional Model No: Please Refer To Page 15

Contents. Report No.: EMC-CE-2114 Page: 2 of 39

Page 1 of 19 No.: HM TEST REPORT FCC PART 15 SUBPART C CERTIFICATION REPORT FOR LOW POWER TRANSMITTER. TEST REPORT No.

Tested To The. and. Report. We strive to TESTING

C E R T I F I C A T I O N

Report for Excelsys EMC Measurements for 4Xgen Purchase Order: Project Number EMT07J026 Rev. B

Transcription:

Report Number : ETLE090324.04 Report issue date: May 26, 2009 Model / Serial No. : JULIET-1 / NONE Multiple Model Name : JULIET-2, JULIET-3, ROMEO-1, ROMEO-2, ROMEO-3 Product Type : Hot & Cold Water Purifier System Brand Name : HYUNDAI, Purifiy Applicant : HYUNDAI Wacor Tec Co., Ltd. Address : 684-49, Gongreung-dong, Nowon-gu, Seoul, Korea Manufacturer : HYUNDAI Wacor Tec Co., Ltd. Address : 684-49, Gongreung-dong, Nowon-gu, Seoul, Korea Test Standard(s) : J55014-1(H20) CISPR14-1: 1993 + A1: 1996 Test Result : Positive Total pages including Attachments : 37 Prepared by: Yoon Seop, Kim (Test Engineer) Reviewed by: Yo Han, Park (Chief Engineer) May 26, 2009 May 26, 2009 ETL Inc. 371-51, Gasan-dong, Geumcheon-gu, Seoul, 153-803, Korea Tel : 82-2-858-0786 Fax : 82-2-858-0788 The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory. Report no. ETLE090324.04 / Page 1 of 12

DIRECTORY Pages A) Documentation Directory 2 Test Standards 3 Address of the test laboratory, Conditions/Power Utilized, Description of the EUT & Symbol Definitions 4 Equipment under Test 8 General Remarks & Summary 9 Test Setups (Photographs) 10 12 B) Test Data Conducted Emissions 150 khz - 30 MHz 5 Disturbance Power 30 MHz - 300 MHz 6 Discontinuous Disturbance 150 khz, 500 khz, 1.4 MHz, 30 MHz 7 C) Attachment A. Test Data and Test Setup Drawing(s) A1 A12 B. List of Test Equipments B1 B2 C. Photo documentations C1 C9 D. Technical description of the test sample D1 D2 Report no. ETLE090324.04 / Page 2 of 12

TEST STANDARD(S) The emc tests were performed according to the following standards: J55014-1(H20) CISPR14-1: 1993 + A1: 1996 Report no. ETLE090324.04 / Page 3 of 12

ADDRESS OF THE TEST LABORATORY Seoul EMC Laboratory #371-51 Gasan-dong, Geumcheon-gu, Seoul, 153-803, Korea Hwaseong Open Area Test Site #499-1, Sagot-ri, Seosin-myeon, Hwaseong-si, Gyeonggi-do, 445-882, Korea ENVIRONMENTAL CONDITIONS During the measurement the environmental conditions were within the listed ranges: Temperature : 15 C - 35 C Humidity : 30 %R.H. - 60 %R.H. Atmospheric Pressure : 86 kpa - 106 kpa POWER SUPPLY SYSTEM UTILIZED Power supply system AC 100 V; 50 Hz/60 Hz; Max. 600 W SHORT DESCRIPTION OF THE EQUIPMENT UNDER TEST (EUT) Number of received / tested samples: 1 / 1 Serial Number: none VOLTAGE RANGE TEST Preliminary test has been performed with voltage conditions of from 90 V (50 Hz / 60 Hz) to 110 V (50 Hz / 60 Hz) at the frequencies of 160 khz and 50 MHz to determine maximum disturbance voltage condition. A test at about 160 khz and at about 50 MHz shall be made over a range of 0.9 to 1.1 times the rated voltage in order to check whether the level of disturbance varies considerably with the supply voltage. The frequencies of 160 khz measurement result is maximum disturbance voltage condition. But the frequencies of 50 MHz measurement result is no maximum disturbance voltage condition. So conducted emissions test condition is AC 100 V, 50 Hz and AC 100 V, 60 Hz. And discontinuous disturbance emissions test condition is normal AC 100 V, 50 Hz and AC 100 V, 60 Hz DEFINITIONS FOR SYMBOLS USED IN THIS The black square indicates that the listed condition, standard or equipment is applicable for this report. Blank box indicates that the listed condition, standard or equipment was not applicable for this report. Report no. ETLE090324.04 / Page 4 of 12

Conducted Emission (Interference Voltage) Test Conducted emissions were measured from 150 khz to 30 MHz with a bandwidth of 9 khz on the 100 V AC power and return leads of the EUT according to the methods defined in J55014-1(H20). The EUT was floor-standing arrangement. The EUT was placed on the horizontal ground reference plane, orientated for normal use, but separated from metallic contact with the ground reference plane of insulation. Test not applicable Test area - shielded room Anechoic chamber Full compact chamber Used test instruments and test accessories please see Attachment B. Type Mains terminals Frequency Range (MHz) Quasi-Peak limit (db μv ) Average limit (db μv ) 0.15 to 0.5 66 to 56 59 to 46 0.5 to 5 56 46 5 to 30 60 50 Pass Fail Minimum limit margin 3.03 db at 29.490 MHz Maximum limit exceeding db at MHz Remarks: Please refer to the test data and graph in Attachment A. Report no. ETLE090324.04 / Page 5 of 12

Disturbance Power Emissions Test Disturbance power emissions form 30 MHz to 300 MHz were measured with a bandwidth of 120 khz according to the methods defines in J55014-1(H20). The EUT was floor-standing arrangement. The EUT was placed on the horizontal ground reference plane, orientated for normal use, but separated from metallic contact with the ground reference plane of insulation. Test not applicable Test area - compact chamber Used test instruments and test accessories please see Attachment B. Type Frequency Range (MHz) Quasi-Peak limit (dbpw) Average limit (dbpw) Household 30-300 45-55 35-45 Pass Fail Minimum limit margin 5.73 db at 36.96 MHz Maximum limit exceeding db at MHz Remarks: Please refer to the test data and graph in Attachment A. Report no. ETLE090324.04 / Page 6 of 12

Discontinuous Disturbance Emissions Test Discontinuous disturbance emissions form 148.5 khz to 30 MHz were measured with a bandwidth of 9 khz according to the methods defines in J55014-1(H20). The EUT was placed on a nonmetallic stand in a shielded room, 0.8 m above the ground plane. Test not applicable Test area - shielded room Used test instruments and test accessories please see Attachment B. Pass Fail Remarks: Please refer to the test data in Attachment A. Report no. ETLE090324.04 / Page 7 of 12

Equipment Under Test (EUT) Test Operation Mode: The equipment under test was operated under the following conditions during testing: During the test, EUT was the continuous cooling & heating mode hold down that the discharge water periodically Configuration of the equipment under test: See constructional data form in Attachment D - Page D2 See product information form(s) in Attachment D - Page D3 The following devices and interface cables were connected during the testing: Peripheral devices Type Model Serial No. Manufacturer Water Pump EC-101-50 0240105 E-CHEN Adapter (for Water Pump) N2401A NONE NONE Type of Cables Used Device from Device to Type of Cable(Port) Length(m) Type of shield EUT Power socket AC Input 1.2 Unshielded Water Pump Adapter AC Input 1.2 Unshielded Report no. ETLE090324.04 / Page 8 of 12

GENERAL REMARKS: The Equipment Under Test (EUT) is the HYUNDAI Wacor Tec Co., Ltd. (model: JULIET-1) The model JULIET-1 is basic model that was tested. The multi models JULIET-2, JULIET-3, ROMEO-1, ROMEO-2 and ROMEO-3 are identical to basic model, except for external design and dimension. Model JULIET-1 (Basic model) JULIET-2 Dimension 370 mm (W) x 410 mm (D) x 1 300 mm (H) 370 mm (W) x 410 mm (D) x 1 200 mm (H) JULIET-3 370 mm (W) x 410 mm (D) x 510 mm (H) ROMEO-1 ROMEO-2 ROMEO-3 370 mm (W) x 410 mm (D) x 1 300 mm (H) 370 mm (W) x 410 mm (D) x 1 200 mm (H) 370 mm (W) x 410 mm (D) x 510 mm (H) SUMMARY: All tests according to the regulations cited on page 3 were Performed Not Performed The Equipment Under Test - Fulfills the general approval requirements cited on page 3. - Does not fulfill the general approval requirements cited on page 3. Date of receipt of test sample: March 24, 2009 Test start date: May 11, 2009 Test end date: May 13, 2009 Report no. ETLE090324.04 / Page 9 of 12

Photograph of test setup: Conducted emissions 150 khz - 30 MHz Report no. ETLE090324.04 / Page 10 of 12

Photograph of test setup: Disturbance Power Report no. ETLE090324.04 / Page 11 of 12

Photograph of test setup: Discontinuous Disturbance Report no. ETLE090324.04 / Page 12 of 12

Attachment A Test Data and Test Setup Drawing(s) Report no. ETLE090324.04 / Page A1 of A12

Conducted Emissions Measurement EUT Hot & Cold Water Purifier System / JULIET-1 (S/N: N/A) Limit apply to J55014-1(H20) Test Date May 11, 2009 Operating Condition Operating Spec. Result During the test, EUT was the continuous cooling & heating mode hold down that the discharge water periodically 100 V, 50 Hz Passed by 4.68 db Conducted Emission Test Data The following table shows the highest levels of conducted emissions on both polarizations of hot and neutral line. Detector mode: CISPR Quasi-Peak mode (6 db Bandwidth: 9 khz) Frequency [MHz] Quasi-peak Result [db μv ] Average Phase (*H/**N) Limit [db μv ] Margin [db] Quasi-peak Average Quasi-peak Average 0.155 35.12 13.24 N 65.73 58.65 30.61 45.41 0.265 31.13 3.96 N 61.27 52.86 30.14 48.90 0.370 29.93 2.55 N 58.50 49.25 28.57 46.70 4.440 24.71 13.32 H 56.00 46.00 31.29 32.68 5.655 32.42 20.12 H 60.00 50.00 27.58 29.88 6.780 47.92 32.24 H 60.00 50.00 12.08 17.76 22.120 36.00 34.93 H 60.00 50.00 24.00 15.07 29.490 45.58 45.32 N 60.00 50.00 14.42 4.68 NOTES: 1. * H : HOT Line, **N : Neutral Line 2. Margin value = Limit Result 3. All conditions were investigated and the worst-case emissions are reported. 4. If the limit for the measurement with the average detector is met when using a receiver with a quasi-peak detector, the equipment under test shall be deemed to meet both limits and the measurement using the receiver with an average detector need not be carried out. Yoon Seop, Kim Test Engineer Report no. ETLE090324.04 / Page A2 of A12

Line Polarity : Hot Limit : Quasi-Peak Average Line Polarity : Neutral Quasi-peak Average Report no. ETLE090324.04 / Page A3 of A12

EUT Hot & Cold Water Purifier System / JULIET-1 (S/N: N/A) Limit apply to J55014-1(H20) Test Date May 11, 2009 Operating Condition Operating Spec. Result During the test, EUT was the continuous cooling & heating mode hold down that the discharge water periodically 100 V, 60 Hz Passed by 3.03 db Conducted Emission Test Data The following table shows the highest levels of conducted emissions on both polarizations of hot and neutral line. Detector mode: CISPR Quasi-Peak mode (6 db Bandwidth: 9 khz) Frequency [MHz] Quasi-peak Result [db μv ] Average Phase (*H/**N) Limit [db μv ] Margin [db] Quasi-peak Average Quasi-peak Average 0.155 33.92 13.10 N 65.73 58.65 31.81 45.55 0.375 29.95 3.42 N 58.39 49.11 28.44 45.69 3.405 23.90 9.72 H 56.00 46.00 32.10 36.28 4.305 25.44 11.70 H 56.00 46.00 30.56 34.30 5.745 30.77 18.69 H 60.00 50.00 29.23 31.31 6.790 44.56 31.87 H 60.00 50.00 15.44 18.13 22.120 43.69 42.96 N 60.00 50.00 16.31 7.04 29.490 47.40 46.97 N 60.00 50.00 12.60 3.03 NOTES: 1. * H : HOT Line, **N : Neutral Line 2. Margin value = Limit Result 3. All conditions were investigated and the worst-case emissions are reported. 4. If the limit for the measurement with the average detector is met when using a receiver with a quasi-peak detector, the equipment under test shall be deemed to meet both limits and the measurement using the receiver with an average detector need not be carried out. Yoon Seop, Kim Test Engineer Report no. ETLE090324.04 / Page A4 of A12

Line Polarity : Hot Limit : Quasi-Peak Average Line Polarity : Neutral Quasi-peak Average Report no. ETLE090324.04 / Page A5 of A12

Disturbance Power Measurement EUT Hot & Cold Water Purifier System / JULIET-1 (S/N: N/A) Limit apply to J55014-1(H20) Test Date May 12, 2009 Operating Condition Operating Spec. Result During the test, EUT was the continuous cooling & heating mode hold down that the discharge water periodically 100 V, 50 Hz Passed by 5.73 db Disturbance Power Test Data Frequency [MHz] Result [dbpw] Limit [dbpw] Margin [db] Quasi-peak Average Quasi-peak Average Quasi-peak Average 36.96 31.13 29.53 45.26 35.26 14.13 5.73 80.08 34.20 19.87 46.85 36.85 12.65 16.98 110.68 28.96 27.11 47.99 37.99 19.03 10.88 125.44 27.76 24.86 48.53 38.53 20.77 13.67 177.04 26.59 23.83 50.45 40.45 23.86 16.62 Yoon Seop, Kim Test Engineer Report no. ETLE090324.04 / Page A6 of A12

dbpw 1 QP MAXH 100 90 80 Att 10 db RBW 120 khz MT 100 ms PREAMP OFF 80 MHz 120 MHz 160 MHz 200 MHz 240 MHz 280 MHz LIMIT CHECK PASS 2 AV MAXH 70 TDF 60 PRN 50 EN55014Q 40 EN55014A 30 20 10 0 30 MHz 300 MHz Report no. ETLE090324.04 / Page A7 of A12

EUT Hot & Cold Water Purifier System / JULIET-1 (S/N: N/A) Limit apply to J55014-1(H20) Test Date May 12, 2009 Operating Condition Operating Spec. Result During the test, EUT was the continuous cooling & heating mode hold down that the discharge water periodically 100 V, 60 Hz Passed by 6.53 db Disturbance Power Test Data Frequency [MHz] Result [dbpw] Limit [dbpw] Margin [db] Quasi-peak Average Quasi-peak Average Quasi-peak Average 36.96 31.13 28.73 45.26 35.26 14.13 6.53 110.68 28.96 28.84 47.99 37.99 19.03 9.15 125.32 27.76 24.64 48.53 38.53 20.77 13.89 140.16 29.28 26.71 49.08 39.08 19.80 12.37 176.96 26.50 26.39 50.44 40.44 23.94 14.05 Yoon Seop, Kim Test Engineer Report no. ETLE090324.04 / Page A8 of A12

dbpw 1 QP MAXH 100 90 80 Att 10 db RBW 120 khz MT 100 ms PREAMP OFF 80 MHz 120 MHz 160 MHz 200 MHz 240 MHz 280 MHz LIMIT CHECK PASS 2 AV MAXH 70 TDF 60 PRN 50 EN55014Q 40 EN55014A 30 20 10 0 30 MHz 300 MHz Report no. ETLE090324.04 / Page A9 of A12

Discontinuous Disturbance Measurement EUT Hot & Cold Water Purifier System / JULIET-1 (S/N: N/A) Limit apply to J55014-1(H20) Test Date May 11, 2009 Operating Condition Result During the test, EUT was the continuous cooling & heating mode hold down that the discharge water periodically Passed Phase : Hot( dbμv ) Click 150 500 1.4 30 Click 150 500 1.4 30 khz khz MHz MHz khz khz MHz MHz 1 0 0 0 0 21 0 0 0 0 2 0 0 0 0 22 0 0 0 0 3 0 0 0 0 23 0 0 0 0 4 0 0 0 0 24 0 0 0 0 5 0 0 0 0 25 0 0 0 0 6 0 0 0 0 26 0 0 0 0 7 0 0 0 0 27 0 0 0 0 8 0 0 0 0 28 0 0 0 0 9 0 0 0 0 29 0 0 0 0 10 0 0 0 0 30 0 0 0 0 11 0 0 0 0 31 0 0 0 0 12 0 0 0 0 32 0 0 0 0 13 0 0 0 0 33 0 0 0 0 14 0 0 0 0 34 0 0 0 0 15 0 0 0 0 35 0 0 0 0 16 0 0 0 0 36 0 0 0 0 17 0 0 0 0 37 0 0 0 0 18 0 0 0 0 38 0 0 0 0 19 0 0 0 0 39 0 0 0 0 20 0 0 0 0 40 0 0 0 0 Lc = 20 log (30/N) = N < 0.2 (5min) + 44 db N = Click / min 0.2 < N < 30 + Lc Click = 10 ms < C time < 200 ms N > 30 (2sec) + 0 db (Industry machine + 10 db ) Measurement Relay Time; 5 min Click Frequency 150 khz 500 khz 1.4 MHz 30 MHz Contin.Limit L st 66 56 56 60 Click Rate 0 0 0 0 Click level Lc 44 44 44 44 L = Lc + Lst 110 100 100 104 Number of Click 0 0 0 0 Numer over limit 0 0 0 0 Passed PASS PASS PASS PASS REMARKS: Report no. ETLE090324.04 / Page A10 of A12

Phase : Neutral( dbμv ) Click 150 500 1.4 30 Click 150 500 1.4 30 khz khz MHz MHz khz khz MHz MHz 1 0 0 0 0 21 0 0 0 0 2 0 0 0 0 22 0 0 0 0 3 0 0 0 0 23 0 0 0 0 4 0 0 0 0 24 0 0 0 0 5 0 0 0 0 25 0 0 0 0 6 0 0 0 0 26 0 0 0 0 7 0 0 0 0 27 0 0 0 0 8 0 0 0 0 28 0 0 0 0 9 0 0 0 0 29 0 0 0 0 10 0 0 0 0 30 0 0 0 0 11 0 0 0 0 31 0 0 0 0 12 0 0 0 0 32 0 0 0 0 13 0 0 0 0 33 0 0 0 0 14 0 0 0 0 34 0 0 0 0 15 0 0 0 0 35 0 0 0 0 16 0 0 0 0 36 0 0 0 0 17 0 0 0 0 37 0 0 0 0 18 0 0 0 0 38 0 0 0 0 19 0 0 0 0 39 0 0 0 0 20 0 0 0 0 40 0 0 0 0 Lc = 20log (30/N) = N < 0.2 (5min) + 44dB N = Click / min 0.2 < N < 30 + Lc Click = 10ms < C time < 200ms N > 30 (2sec) + 0dB (Industry machine + 10dB ) Measurement Relay Time; 5 min Click Frequency 150 khz 500 khz 1.4 MHz 30 MHz Contin.Limit L st 66 56 56 60 Click Rate 0 0 0 0 Click level Lc 44 44 44 44 L = Lc + Lst 110 100 100 104 Number of Click 0 0 0 0 Numer over limit 0 0 0 0 Passed PASS PASS PASS PASS REMARKS: Report no. ETLE090324.04 / Page A11 of A12

The setup drawing(s) Water Bucket EUT Water Pump : Data Line : Hose : Power Line : Adapter Report no. ETLE090324.04 / Page A12 of A12

Attachment B List of Test Equipment Report no. ETLE090324.04 / Page B1 of B2

Emission Test Equipments Description Model Number Manufacturer Serial Number Cal Due Date EMI TEST Receiver ESHS 30 R & S 840190/002 10.03.30 EMI TEST Receiver ESPI3 R & S 100478 09.10.02 LISN 3825/2 EMCO 9208-1995 09.10.01 LISN 3816-2 EMCO 1002 09.10.01 Absorbing Clamp MDS-21 R & S 100157 10.03.30 Report no. ETLE090324.04 / Page B2 of B2

Attachment C Constructional Photographs of Equipment Under Test (EUT) Report no. ETLE090324.04 / Page C1 of C9

View of front Report no. ETLE090324.04 / Page C2 of C9

View of rear Report no. ETLE090324.04 / Page C3 of C9

View of side Report no. ETLE090324.04 / Page C4 of C9

View of side Report no. ETLE090324.04 / Page C5 of C9

View of inside Report no. ETLE090324.04 / Page C6 of C9

View of inside Report no. ETLE090324.04 / Page C7 of C9

View of inside Report no. ETLE090324.04 / Page C8 of C9

View of inside Report no. ETLE090324.04 / Page C9 of C9

Attachment D Constructional Data Form and Product Information Form(s) Report no. ETLE090324.04 / Page D1 of D2

CONSTRUCTION DATAFORM FOR EMC TESTING Applicant Address Factory Address : HYUNDAI Wacor Tec Co., Ltd. : 684-49, Gongreung-dong, Nowon-gu, Seoul, Korea : HYUNDAI Wacor Tec Co., Ltd. : 684-49, Gongreung-dong, Nowon-gu, Seoul, Korea Type : Hot & Cold Water Purifier System Rated voltage : AC 100 V; 50 Hz/60 Hz Serial No. : NONE Rated input power : Max. 600 W Protection type : Protection class : Configuration of equipment: Rev. : Rev. : Rev. : Source of interference : Internal frequency : Noise suppression components : Measures for electromagnetic shielding : Place of issue date Seal and signature of applicant If applicable, if necessary complete overleaf Report no. ETLE090324.04 / Page D2 of D2 End of test report