RX 3 ->CATALOG PAGES INSIDE. the global specialist

Similar documents
RX 3 ->CATALOG PAGES INSIDE. the global specialist

NEW CIRCUIT PROTECTIONRANGE

DRIVIA cabinets LIMOGES Cedex France 1. DESCRIPTION, USE 3. DIMENSIONS 2. RANGE, CAT. NO. EQUIVALENCE TABLE

DPX TM MCCBs LP* Description Cat. nos. ` / Pack Unit

COPYTRACER Anti-counterfeit registration number

Add-on modules DX 3 63A for MCBs DX 3 1,5 modules per pole

NIRAPOD 1. High performance circuit breaker mcb and combined mcb with remote controls. LV Distribution Products 2-63A

(1,5 modules per pole)

2.7. IT system floor-standing distribution cabinet Series -IPS-F/EDS

Btdin RCD Add-on modules 63A for MCBs 1,5 modules per pole

Technical features table for miniature circuit-breakers SH 200 Series


Section five. Connection systems. Isobar 4 Evo MCB pan assemblies Mulitclip busbar and Polybloc 126. Comb busbars 127

sustainable savings that can be viewed directly on the internet

Circuit Breakers. Excerpt from Master Catalogue. Circuit Breakers. Specifically For You

Trunkingxxxxxx. in aluminium. Industrial Catalogue

Cable Management Solutions with DLP TM

PHOENIX CONTACT

Trunkingxxxxxx. aluminium colour U23X. Industrial Catalogue

PHOENIX CONTACT

ZUCCHINI MS - LOW TO MEDIUM POWER BUSBAR

RCP IP68 RESIN BUSBAR TRUNKING GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURE

5/2 Introduction. Unequipped Distribution Boards 5/4 Modular distribution boards 5/5 Add-on parts

Btdin RCD Add-on Modules 32A - 63A for M.C.Bs 1 module per pole

Measuring current transformers of the W, W series

Page 13-2 Page Page 13-7

C.A 6115N. Safety at all costs. IEE 16th: Electrical installation IEC/EN I E C. Insulation RCD. Earth. Loop. Continuity.

Btdin RCD Add-on Modules 32A - 63A for M.C.Bs 1 module per pole

4/2 Introduction. Marshaling Boxes 4/8 8GK1 surface-mounting distribution boards

Raised Floor system LIMOGES Cedex. Phone : Fax :

2/2 Introduction. Unequipped Distribution Boards 2/5 8GK1 surface and flush-mounting distribution boards

DLP mini trunking. DLP U-PVC trunking system mini-trunking system. DLP U-PVC trunking system and accessories 80 x 50. Comfortable implementation

Protective Relays Digitrip 3000

Electronic Circuit Breaker ESS20-0..

Residual Current-operated Circuit Breakers (RCCBs) F 360 and F 370 Range

Residual current circuit breakers (RCCBs)

Michigan State University Construction Standards SWITCHBOARDS, PANELBOARDS, AND CONTROL CENTERS PAGE

Circuit Breakers FAZ / FAZ6. Installation Products for Industrial Applications

Atlantic. ip40-ip65 Metal distribution switchboard. Certifications. Technical features. Electrical properties

Fluke and

Miniature circuit-breakers S 280 UC series. System pro M. Technical data

FINAL - EST Electrical Service Technician Answer Schedule

SIRCO M UL98 Load break switches standards UL and CSA 30 to 100 A

Controls Contactors and Contactor Assemblies Special Applications

Local control stations for Zone 1 and Zone 21. Features. Description

Installation / Monitoring Technique

DATA SHEET. Switchboard instruments,

Protective earthing, protective conductor and automatic disconnection in case of a fault (Fault protection)

DATA SHEET Selectable AC transducer TAS-311DG

DLP-S Trunking LIMOGES Cedex. Phone : Fax :

ConnectionSolutions 4Workplaces. general catalogue

Flush Floor system LIMOGES Cedex. Phone : Fax :

SAY..P.. A6V ACVATIX Electromotoric actuators for valves. with a 15 mm stroke

Protection and control. Sepam range Sepam 100 LA Self-powering protection. Merlin Gerin Square D Telemecanique

PowerLogic power-monitoring units. PM700 series power meter. Technical data sheet

MANUFACTURING GUIDELINES FOR PLC (LEVEL-1 AUTOMATION)

Integration between the MV protection and control unit REF542 and the LV protection trip unit PR123: selectivity and earth fault 1SDC007402G0201

RISH Ducer TV 808, 2 channels Isolating amplifier unipolar / bipolar

Current / residual current and voltage transformers. Current / residual current and voltage transformers

CROMPTON INSTRUMENTS INTEGRA 1222 DIGITAL METERING SYSTEM

SIRCO M UL 98 Load break switches standards UL and CSA from 30 to 100 A

Circuit protection devices

Technical Data Accessories MCCBs Ex9M.

CDV 22, 62. Voltage Controlled Overcurrent Relay GRID PROTECTION

CROMPTON INSTRUMENTS INTEGRA 1222 DIGITAL METERING SYSTEM

ALPHA DIN Wall-Mounted. Distribution Boards

OptiLine 45 Floor boxes

Technical catalogue. Emax Low voltage air circuit-breakers. Hotline:

Capacitor Switching Contactors

isw switches Control Local control IEC/EN , isw switch with indicator light. IEC/EN , isw switch without indicator light.

FIB / FIC. r with Overcurrent Protection (RCBO) Doepke. » effi cient. » reliable. » fl exible. » future-oriented

Datasheet BR & SU Series UL489/CSA C22.2 No.5-02 (Branch rated) Circuit Breakers UL1077/CSA C22.2 No.235 Supplementary Protectors

Single phase meter with direct connection and pulse or Modbus RS485 output

8 Input/8 Output AC Block I/O Module

Industrial Controls. Catalog IC SIRIUS. Answers for industry.

GLS A GLS 15

MULTIBLOC 00.ST8 Size A, 690VAC Bottom Fitting, 1-,2-,4-pole

Electronic Circuit Breaker with reset input ESS20-1..

Low voltage switchgear

Siemens AG New portfolio for reliable personnel, material and fire protection

T/3000 T/3000. Substation Maintenance and Commissioning Test Equipment

Flexible AC current probes

LBPLUS DATA. he new busbar unking system for LIGHTING MANAGEMENT. Range

Basic Series Square Panel Meters Features Benefits

10. Mini Coax Connectors

Measuring current transformers of the W B series

SAY..P.. A6V ACVATIX Electromotoric actuators for VPI46. with a 15 mm stroke

3-phase meter with direct connection and pulse or Modbus RS485 output

from 0.5 to 125 A Electrical characteristics Sensitivity type (ma) a AC Electrical auxiliaries Auxiliary and alarm switches (OF-SD)

SAX..P. Electromotoric actuators for valves ACVATIX. with a 20 mm stroke

RUDOLF Digital power analyzer. Advanced Version

MISTRAL SYSTEM IMPACT 2

Introduction. Centrado leading-edge transformer. Introduction

Ceiling Mount - 32" to 60" - Single Installation Instructions

T e c h n i c a l C a t a l o g u e MCCB. Moulded Case Circuit Breaker

Output of three-phase motors at 50 Hz and 400 V

10. Mini Coax Connectors

Euromas Polymas. Colour: Silver grey, similar to RAL 7001; special colours on request

C20.en. Power contactors for AC and DC CT1115 and CT1130. Connect - Contact - Control

EMC filters. Mounting instructions. Date: January 2006

Transcription:

RX 3 ESSENTIAL PROTECTION ->CATALOG PAGES INSIDE the global specialist IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

NEW RX 3 RANGE essential The new RX 3 range of RCDs and MCBs provides a response to the essential requirements on residential or small business sites, protecting against short-circuits, overloads and residual current faults. PROTECTION RCDs The breadth of the range covers the essential requirements of sites: C curves, 4500 breaking capacities and residual current protection In = 25 to 63 A 2P Sensitivity: AC type 30/100/300 ma Conform to standard IEC 61008-1

IDEAL FOR BUILDINGS IN THE RESIDENTIAL AND SMALL BUSINESS SECTORS (OFFICES, SHOPS, ETC.) THERMAL-MAGNETIC CIRCUIT BREAKERS In = 6 to 63 A 1P/2P/3P Breaking capacity 4500 at 230/400 VA C curve Conform to standard SNI 04-6507.1-2002 Conform to standard IEC 60898-1 www.legrand.com www.legrand-copytracer.com 1

NEW RX 3 RANGE SAFE, RELIABLE AND EASY TO INSTALL safe, easy wiring: IP2X insulated terminals Large capacity terminals 35 mm 2 Rising clamp terminals Compatible with Phillips or flat screwdriver SIMPLE, VISIBLE MARKING Easy to use, visible marking area whatever the position of the handle Clear, simple, indelible marking for easy identification of the produc QUICK IDENTIFICATION OF THE FUNCTIONS 2 handle colours: Black for circuit breakers Grey for RCDs bistable clips: Easy positioning or removal of the product on its DIN rail 2

AIR FLOW AN ATTRACTIVE, WELL THOUGHT-OUT DESIGN FOR SAFETY AND COMFORT A well-designed shape and careful choice of material for the devices enables air to circulate, limiting any temperature rise between each circuit breaker Neat, attractive finish for greater ease of use RX 3 THE GUARANTEE OF A SAFE, RELIABLE RANGE Long-lasting electrical endurance Use under extreme conditions Optimum protection in the event of short-circuits Quality guaranteed by international approvals 10,000 operations -25 C to +70 C Limitation class 3 www.legrand.com www.legrand-copytracer.com 3

MCBs RX 3 4500 thermal magnetic MCBs from 6 A to 63 A C curves RCDs RX 3 residual current circuit breakers from 25 A to 80 A AC types 4 021 55 4 021 90 4 020 25 4 020 70 Conform to IEC 60898-1 Conform to standard SNI 04-6507.1-2002 Do not accept auxiliaries, and add-on modules Breaking capacity: 4500 - IEC 60898-1 - 230/400 V± 4.5 ka - IEC 60947-2 - 230/400 V± Conform to IEC 61008-1 AC type?: detect AC component faults Pack Cat.Nos Single pole 230/400 VA C curve Nominal rating In (A) Number of modules 10 4 021 52 6 1 10 4 021 53 10 1 10 4 021 55 16 1 10 4 021 56 20 1 10 4 021 57 25 1 10 4 021 58 32 1 10 4 021 59 40 1 10 4 021 60 50 1 10 4 021 61 63 1 2-pole 230/400 VA C curve Nominal rating In (A) Number of modules 5 4 021 83 6 2 5 4 021 84 10 2 5 4 021 86 16 2 5 4 021 87 20 2 5 4 021 88 25 2 5 4 021 89 32 2 5 4 021 90 40 2 5 4 021 91 50 2 5 4 021 92 63 2 3-pole 400 VA C curve Nominal rating In (A) Number of modules 1 4 021 94 6 3 1 4 021 95 10 3 1 4 021 97 16 3 1 4 021 98 20 3 1 4 021 99 25 3 1 4 022 00 32 3 1 4 022 01 40 3 1 4 022 02 50 3 1 4 022 03 63 3 Pack Cat.Nos RX 3 RCDs 2-pole - 230 V± AC type? 30 ma In (A) Number of modules 1 4 020 24 25 2 1 4 020 25 40 2 1 4 020 26 63 2 1 4 020 27 80 2 AC type? 100 ma 1 4 020 28 25 2 1 4 020 29 40 2 1 4 020 30 63 2 AC type? 300 ma 1 4 020 32 25 2 1 4 020 33 40 2 1 4 020 34 63 2 RX 3 RCDs 4-pole - 400 V± neutral on right-hand side AC type? 30 ma In (A) Number of modules 1 4 020 62 25 4 1 4 020 63 40 4 1 4 020 64 63 4 AC type? 100 ma 1 4 020 66 25 4 1 4 020 67 40 4 1 4 020 68 63 4 AC type? 300 ma 1 4 020 70 25 4 1 4 020 71 40 4 1 4 020 72 63 4 4

supply busbars, entry terminals "standard" distribution NEW supply busbars, entry terminals "standard" distribution n Technical characteristics 4 049 44 4 049 26 4 049 05 Max. Length Cross Permissible current: Busbars number in number section 1 central types of devices of 17.5 mm (mm 2 ) power 2 power connected modules supply point supply point Single pole or 1 row 13 13 Single pole + neutral Meter 57 57 16 2 80 100 Double pole 1 row 6 12 10 2 63 90 Meter 28 56 16 2 80 100 Double pole 1 row 6 12 102 63 90 balanced on 3-phases Meter 28 56 16 2 80 100 Triple pole 1 row 4 12 10 2 63 90 Meter 19 57 16 2 80 100 Four pole 1 row 3 12 10 2 63 90 Meter 14 56 16 2 80 100 Pack Cat.Nos Prong-type supply busbars Universal single pole + neutral Reversible: blue for neutral, black for live Length Max. number of devices connected 20 4 049 26 1 row 13 10 4 049 37 1 meter 57 n Use of supply busbars Universal single phase + neutral - blue for neutral - black for live Double pole 50 4 049 38 1 1 row 6 10 4 049 39 1 meter 28 Double pole balanced on 3 phases 3 4 049 40 1 1 row 6 10 4 049 41 1 meter 28 Triple pole 40 4 049 42 1 1 row 4 10 4 049 43 1 meter 19 Entry terminal Power supply at the rear of the busbar Power supply at the front of the busbar For all devices with moving cage For all devices with fixed cage terminals terminals Four pole 30 10 4 049 44 4 049 45 1 row 1 meter 3 14 Protection Protection of prongs 20 4 049 88 12 modules Can be cut to length Protection of supply busbar ends 40 4 049 89 For single pole/single pole + neutral 20 20 4 049 90 4 049 91 For double pole length 1 m and triple pole For four-pole Entry terminals 20 4 049 05 For universal single pole + neutral or single pole supply busbars Cross section: 4 to 25 mm 2 - IP 2X 20 4 049 06 For all supply busbars Cross section: 6 to 35 mm 2 Four pole busbar 1: Filled with end protection Red catalogue numbers: New products 5

flush-mounting cabinets Practibox TM 6 to 36 modules flush-mounting cabinets Practibox TM 6 to 36 modules Lateral, top and bottom knock-out entries Mounting of chassis with levelling system Faceplate with integrated door 6 011 11 6 011 14 n Dimensions Cabinets 6,8 and 12 modules IP 40 - IK 07 with door Class II Conform to standard IEC 439 Reversible faceplate Box for masonry White RAL 9003 Supplied without terminal block E 72 A C Pack Cat.Nos Terminal shield boxes To be equipt with terminal blocks cat. no 6 012 90 1/12 6 011 10 1 row of 6 modules 1/12 6 011 11 1 row of 8 modules 1/6 6 011 12 1 row of 12 modules 1/5 6 011 13 2 rows of 12 modules 1/3 6 011 14 3 rows of 12 modules Accessories Blanking plate Separable into modules or 1/2 modules 20 0 016 60 5 modules - white Terminal blocks 10 6 012 90 Neutral and earth - 2 x 8 holes Key lock Only for 2 and 3 rows distribution cabinets 1 0 019 66 N 850 Number of modules 6 mod. 8 mod. 12 mod. A 230 266 334 B 186 188 225 C 208 244 287 D 180 180 208 E 27 27 31 Cabinets 24 and 36 modules C 80 334 289 150 B A D B Number of modules 24 mod. 36 mod. A 376 526 B 358 508 C 40 42 6 Bold pack quantities: Minimum quantities to be ordered

Notes

Notes

FOLLOW US ALSO ON www.legrand.com www.youtube.com/legrand twitter.com/@legrand PT. Intraco Indonesia Ruko Mahkota Ancol Blok C/50 Jl. R. E. Martadinata Kel. Pademangan Barat, Kec. Pademangan Jakarta Utara 14420 INDONESIA Authorized Distributor Of Telp. : +62 21 64717528 : +62 21 64717529 Fax. : +62 21 64717530 E-mail : info@intracoindonesia.co.id : PT. Intraco Indonesia World Headquarters and International Department 87045 Limoges Cedex - France Tel. : + 33 (0) 5 55 06 87 87 Fax : + 33 (0) 5 55 06 74 55 EXB12061 - September 2012