Brochure. Desktop Spectrophotometer

Similar documents
Brochure. Colorimeter. (CD Series ) Global Office of Lisun Electronics Inc.

LCS-A1 SERIES

High Precision CCD Spectroradiometer & Integrating Sphere Test System LPCE-2(LMS-9000B) Brochure. Global Office of Lisun Electronics Inc.

Meter COLOR RGB Display. Measuring geometry 45 /0 - circular illumination at 45, measurement at 0. Spectral range.

Brochure. Automotive Immunity Test System. (ISO7637) Global Office of Lisun Electronics Inc.

Color Spectrum. Color Spectrophotometer EPC / PRODUCTS / APPLICATION / SOFTWARE / ACCESSORIES / CONSUMABLES / SERVICES

SPECTROPHOTOMETER CM-2600d

spectro-guide Total Appearance Control color and gloss in one unit Easy to use and handle Solid Color

The World s Most Trusted Name In Color Quality. HunterLab

SPECTROPHOTOMETER CM-2600d

SPECTROPHOTOMETER CM-2600d. Simply expands the Boundaries in Color Control

Spectrophotometer CM-3630 PaperControl Software

BIO SPECTROPHOTOMETER

ColorEye XTH. ...hand-held color accuracy on the most challenging sizes, shapes and surfaces. Spectrophotometer

SPECTROPHOTOMETER CM-2600d. Simply expands the Boundaries in Color Control

UV / VIS Spectrophotometer

Giving Shape to Ideas

COLOUR / GLOSS Colour

SpectroEye. Spectrophotometer/Densitometer. The simplest and most accurate method for measuring color and density.

SPECTROPHOTOMETER CM-2600d

Multispectral. imaging device. ADVANCED LIGHT ANALYSIS by. Most accurate homogeneity MeasureMent of spectral radiance. UMasterMS1 & UMasterMS2

GCMS-3 GONIOSPECTROPHOTOMETER SYSTEM

JETI Specbos Instruments

Photometric Colorimetry

We bring quality to light. MAS 40 Mini-Array Spectrometer

Color Data Software CM-S100w

specification cylon colorimeter

LM Test Report. for. Philips (China) Investment Co., Ltd. InstantFit LEDtube Model:

Communicating Color. Courtesy of: X-Rite Inc Street SE Grand Rapids MI (616)

SPECTRAL SCANNER. Recycling

Report No.: HZ j. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

Spectrophotometer CM-3630 PaperControl Software

CR-400/410 CR-400 CR-410

Using DIAGNOSE.EXE with a ColorQuest 45/0

Chapter Objectives. Color Management. Color Management. Chapter Objectives 1/27/12. Beyond Design

A REVIEW OF COLOR MEASURMENTS IN THE TEXTILE INDUSTRY

UV / VIS Spectrophotometer EMCLAB Instruments GmbH

BYK-Gardner. Gloss and Color. Wesel, 2016, Henrik Folkerts

Contents I. APPLICATIONS II. SPECIFICATIONS III. PRINCIPLES IV OPERATION V. MAINTENANCE

LM Test Report. for Elec-Tech International Co.,Ltd. LED CEILING LIGHT Model: XX(XX: 01-10)

BTS256-E WiFi - mobile light meter for photopic and scotopic illuminance, EVE factor, luminous color, color rendering index and luminous spectrum.

Lynx-Eyed. Inline Measuring Color Sensors with D65 Similar Optical Spectrum.

Lynx-Eyed. Inline Measuring Color Sensors with D65 Similar Optical Spectrum.

LM Test Report. for Elec-Tech International Co.,Ltd. LED CEILING LIGHT Model: XX(XX: 61-70)

NEAR EYE DISPLAY (NED) SPECTRORADIOMETER SYSTEMS DATASHEET

LM Test Report. for Elec-Tech International Co.,Ltd. LED CEILING LIGHT Model: XX(XX: 01-10)

Color More than meets the Eye

Imaging Photometer and Colorimeter

Integrating Spheres. Why an Integrating Sphere? High Reflectance. How Do Integrating Spheres Work? High Damage Threshold

Graphic technology Spectral measurement and colorimetric computation for graphic arts images

SpectraMagic TM NX. Color Data Software CM-S100w. Color Quality control like never before:

Chameleon Spectroradiometer

Spectroradiometer specbos 1201

LM Test Report. for Maxlite SK America Inc. 2*4 Retrofit Kits Model: RKT4514U5550DV

Chroma Meter CL-200A. Even measures new light sources such as LED lighting and organic EL lighting

Spectrophotometer CM-2500c. Instruction Manual

T92+ UV-VIS SPECTROPHOTOMETER

Instruction manual for Ocean Optics USB4000 and QE65 Pro spectroradiometers

Featuring new judgment and ranking functionality LED OPTICAL METER TM6101. < Primary measurement application >

Lovibond Tintometer PFXi-195/1 & PFXi-195/2

Agilent Cary 7000 Universal Measurement Spectrophotometer (UMS)

LM Test Report. for Elec-Tech International Co., Ltd. BR40 LAMP Model: XX(XX:01-10), WBR40L27S2A

ISO INTERNATIONAL STANDARD. Graphic technology Spectral measurement and colorimetric computation for graphic arts images

A Step-wise Approach for Color Matching Material that Contains Effect Pigments. Dr. Breeze Briggs, BASF Colors & Effects USA LLC, ANTEC 2017

LM Test Report. for Elec-Tech International Co.,Ltd. LED PAR30 Spot light Model: XX(XX:41-50)

BTS256-PAR. Product tags: VIS, Spectral Data, PAR, Waterproof, General lighting.

Whiteness indices and UV standards

LCM plus. Operating Instructions

Color images C1 C2 C3

THE MEASUREMENT OF APPEARANCE

High-Accuracy Luminance & Chromaticity Measurement Comparable to Many Spectroradiometers

Achieving 100,000 : 1 contrast measurement

UVS-2800 Spectro UV-VIS Split Beam (PC) is a precise scanning

Multimedia Systems and Technologies

Gamma Scientific Display Measurement Systems

PHOTO RESEARCH, INC. PR-730 / PR-735 and PR-740 / PR-745 SpectraScan

Instrument Description

Fire testing: Calibration of smoke opacity measuring systems

LM Test Report. for Maxlite SK America Inc. WALLPACK Model: MLSWP30LED50DS

K13250 LICO 100 Portable Color Measurement System

NANOCOLOR PC Software for Spectrophotometers

CS-2000/2000A. Spectroradiometer NEW

T 519 om-96 SUGGESTED METHOD 1970 OFFICIAL STANDARD 1978 OFFICIAL TEST METHOD 1980 REVISED 1986 REVISED 1991 REVISED TAPPI

LI-193 Spherical Quantum Sensor

Report No.: HZ f. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

Endress Hauser The Power of Know How. Turbidity and Solids Content Sensor TurbiMax P CUS 63 / CUS 63H

Diffuse opacity of paper (d/0 paper backing) (Revision of T 519 om-02)

Spectro-Densitometers: Versatile Color Measurement Instruments for Printers

Lambda X65 series. UV/Vis Simplified for your Lab. Gerlinde Wita October 2015

Lambda 1050 / 950 UV/Vis/NIR

EDUCATION EXPERIMENT. Determining Color Difference (Delta E) Introduction

FY07 New Start Program Execution Strategy

Ideal for display mura (nonuniformity) evaluation and inspection on smartphones and tablet PCs.

IGPG Car Wash Round Robin Test Procedure

COLOR and the human response to light

SP-8001 UV/Visible Spectrophotometer

Report No.: HZ h/R1. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

QC SOLUTIONS FOR TRANSPARENT PRODUCTS

Report No.: HZ h. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

Imaging Spectophotometers

Transcription:

Brochure Desktop Spectrophotometer (DSCD Series) Global Office of Lisun Electronics Inc. http://www.lisungroup.com Lisun Group (Hong Kong) Limited Add: Room C, 15/F Hua Chiao Commercial Center, 678 Nathan Road, Mongkok, KL, HK Tel: 00852-68852050 Fax: 00852-30785638 Email: SalesHK@Lisungroup.com Lisun Electronics (Shanghai) Co., Ltd Add: 113-114, No. 1 Building, Nanxiang Zhidi Industry Park, No. 1101, Huyi Road, Jiading District, Shanghai, 201802, China Tel: +86(21)5108 3341 Fax: +86(21)5108 3342 Email: SalesSH@Lisungroup.com Chapter 1 Summarize ( 大标题, 居中小三加粗, 尽量在新一页, 用 Chapter 区分 ) Lisun Electronics Inc. (USA) 1. Add: Operating 445 S. Figueroa instruction Street, Los Angeless, ( 一级标题 CA, 90071, 左对齐小四加粗 U.S.A. ) According Email: Sales@Lisungroup.com to the requirements of CIE, IESNA and the National s standard, this system is a multi-measurement mode spectrophotometer system which can realize B-β, Lisun A-α China and Factory C-γ etc through rotating lamps and lanterns. Add: NO. 37, Xiangyuan Road, Hangzhou City, Zhejiang Province, China It Tel: test +86-189-1799-6096 Spatial, light intensity distribution curves on any cross section (can be shown under Email: Engineering@Lisungroup.com the rectangular coordinate system or polar coordinate system), spatial iso-intensity curve. ( 正文, 段首顶格左对齐 10 号, 段落之间空行 ) 1.1 Explosive material ( 二级标题, 左对齐五号加粗 ) Lead in CFL & LED Test Instruments According to the requirements of CIE, IESNA and the National s standard, this Rev. 1/16/2019

Loaded spectrophotometer (DSCD-900) Basic Introduction DSCD-900 is a highly performance spectrophotometer with test caliber upward. The instrument adopts the geometric conditions of D/8 lighting and observation of CIE recommendations, integration of the full band LED composite light source, double beam optical system, ETC every-time calibration technology, spectral reflectance standard deviation within 0.08, maximum of colorimetric values ΔE*ab is 0.03, to provide all the necessary color formula. It could be widely used for coating, printing, textile, meet plastic, food, medicine, automobile field to meet customers measurement requirement. DSCD-900 Bearing type test Solid samples (steel, cloth) can be placed directly on the measurement port, particles (tablets, master batch), powder (pigment, coffee), paste objects (tomato sauce) can be placed in a Petri dish, and then placed in the measurement port. D\8 Structure Our device adopts internationally observe condition D/8 (Diffused lighting, 8 degrees observe angle) and SCI (specular reflection included)/sce (specular reflection excluded). -Page 1 -

Can Measure SCI and SCE at the same time ETC Technology (Every Test Calibration) Color Quality Control software Our spectrophotometer comes with the color QC software, which is applicable in various industries quality control and management of color data. It turns color into numerical data, compares color differences, and generates measurement reports. provides measurement data under different color spaces and customizes color management for each customer. More Product Pictures -Page 2 -

Technical Data DSCD-900 Illumination d/8(diffused illumination, 8 viewing) (conform to CIE No.15 ISO 7724/1 ASTM E1164 DIN 5033 Teil7 JIS Z8722 Condition c standards) Size of integrating sphere Φ40mm,Alvan diffused reflection surface coating Illumination Light source CLEDs(entire wavelength balanced LED light source) Sensor dual optical path sensor array Wavelength range Wavelength interval Half spectral width Reflectivity range Resolution 400-700nm 10nm 5nm 0-200% 0.01% -Page 3 -

DSCD-900 Observer angle Measurement Light Source Data being displayed Measurement time 2 /10 A,C,D50,D55,D65,D75,F1,F2,F3,F4,F5,F6,F7,F8, F9,F10,F11,F12,DLF,TL83,TL84,NBF,U30,CWF Reflectance graph/value, chromatic value, color difference values, color assessment results, color tendency, display measurement area, history color value simulation, manual input standard sample, generate measurement reports About 1 second Measurement time interval Measuring caliber Color space 0.5 second Φ11mm CIE-L*a*b,L*C*h,L*u*v, XYZ, Yxy, reflectivity, Hunterlab, Munsell MI,CMYK,RGB,HSB Color difference formulas ΔE*ab,ΔE*CH,ΔE*uv,ΔE*cmc(2:1),ΔE*cmc(1:1),ΔE*94,ΔE*00,ΔEab(Hunter),555color classification Other colorimetric indices Repeatability WI(ASTM E313-00,ASTM E313-73,CIE/ISO, AATCC, Hunter, Taube Berger Stensby), YI(ASTM D1925,ASTM E313-00,ASTM E313-73), Tint(ASTM E313,CIE,Ganz),metamerism index Milm, adhesive/changing color fastness, ISO luminance,8 gloss, A density, T ensity, E ensity, M ensity light splitting reflectivity: standard deviation within 0.08% color values: ΔE*ab<=0.015(After calibration, standard deviation of 30 measurements on test white board, 5 second intervals),maximum: 0.03 Battery capacity rechargeable, 20000 continuous tests, 7.4V/6000mAh Interface Data storage Light source longevity USB 40000 test results 5 years, 1.5 million tests -Page 4 -

Inter-instrument agreement Size Weight Display Work temperature range Storage temperature range DSCD-900 ΔE*ab within 0.2 (BCRA color charts II, average of the 12 charts) 350*300*200mm(L*W*H) 4.5kg 5 inches True color screen 0~45, relative humidity 80% or below(at 35 C), no condensation -25 to 55, relative humidity 80% or below(at 35 C), no condensation Standard accessories Optional accessories Color matching system UV light source AC power line, operating manual, color QC software, driving software, electric operating manual, USB cable, white/black calibration tile, verification certification powder molding device, cuvette, shading cover Matches without Application Non transparent solution Mash Powder Granule -Page 5 -

Desktop Spectrophotometer (DSCD-901) Basic Introduction DSCD-901 is a high performance spectrophotometer with test caliber sideward. The instrument adopts the geometric conditions of D/8 lighting and observation of CIE recommendations, integration of the full band LED composite light source, double beam optical system, ETC every-time calibration technology, spectral reflectance standard deviation within 0.08, maximum of colorimetric values ΔE*ab is 0.03, to provide all the necessary color formula. It could be widely used for coating, printing, textile, meet plastic, food, medicine, automobile field to meet customers measurement requirement. DSCD-901 Brief Introduction Side color measurement Its test caliber is in the sideward, it will be more convenient to fix the sample. Solid samples (steel, cloth) can be placed directly on the measurement port. Paste objects can be placed in a cuvetee, and then placed in the measurement port. It is very suitable for powder material testing in case of material falling into the integrating sphere to affect the testing accuracy. D\8 Structure Our device adopts internationally agreed observe condition D/8 (Diffused lighting, 8 degrees observe angle) and SCI (specular reflection included)/sce (specular reflection excluded). -Page 6 -

Can Measure SCI and SCE at the same time ETC Technology (Every Test Calibration) Color Analysis Software Our spectrophotometer comes with the color management software, which is applicable in various industries quality control and management of color data. It turns color into numerical data, compares color differences, generate measurement reports. Provides measurement data under different color spaces and customizes color management for each customer. -Page 7 -

More Product Pictures Technical Data DSCD-901 Illumination d/8(diffused lighting, 8 degrees observe angle) (conform to CIE No.15 ISO 7724/1 ASTM E1164 DIN 5033 Teil7 JIS Z8722 Condition c standards) Size of integrating sphere Φ40mm,Avian diffused reflection surface coating Illumination Light source CLEDs(entire wavelength balanced LED light source) Sensor dual light path sensor array Wavelength range Wavelength interval Half spectral width Reflectivity range Reflectivity resolution Observation angle 400-700nm 10nm 5nm 0-200% 0.01% 2 /10 -Page 8 -

Measurement light source Data being displayed Measurement time DSCD-901 A,C,D50,D55,D65,D75,F1,F2,F3,F4,F5,F6,F7,F8, F9,F10,F11,F12,DLF,TL83,TL84,NBF,U30,CWF SPD distribution/data, sample's color values, color difference values/graph, pass/fail results, color error tendency, color simulation, display measurement area, history data color simulation, manual input standard sample, generate measurement report About 1 second Measurement time interval Measuring caliber Color space 0.5 second Φ11mm CIE-L*a*b,L*C*h,L*u*v, XYZ, Yxy, reflectivity, Hunterlab, Munsell MI,CMYK,RGB,HSB Color difference formulas ΔE*ab,ΔE*CH,ΔE*uv,ΔE*cmc(2:1),ΔE*cmc(1:1 ),ΔE*94,ΔE*00,ΔEab(Hunter),555color classification Other colorimetric indices Repeatability Battery capacity WI(ASTM E313-00,ASTM E313-73,CIE/ISO, AATCC, Hunter, Taube Berger Stensby), YI(ASTM D1925,ASTM E313-00,ASTM E313-73), Tint(ASTM E313,CIE,Ganz),metamerism index Milm, adhesive/changing color fastness, ISO luminance,8 gloss, A density, T density, E density, M density light splitting reflectivity: standard deviation within 0.08% color values:δe*ab<=0.015(after calibration, standard deviation of 30 measurements on test white board, 5 second intervals),maximum: 0.03 rechargeable, 20000 continuous tests, 7.4V/6000mAh Interface Data storage Light source longevity USB 40000 test results 5 years, 1.5 million tests -Page 9 -

Inter-instrument agreement Size Weight Display Work temperature range Storage temperature range DSCD-901 ΔE*ab within 0.2( BCRA color charts II, average of the 12 charts) 350*300*200mm(L*W*H) 4.5kg 5 inches True color screen 0~45, relative humidity 80% or below ( at 35 C), no condensation -25 to 55, relative humidity 80% or below ( at 35 C), no condensation Standard accessories Optional accessories Color matching system UV light source AC power line, operating manual, color management software, drive software, electronic operating manual, color management guide, USB cable, black/white calibration tube, protection cover, electronic color charts, measurement and test report powder molding device,40*10 cuvette Matches without Application Non transparent solution Textile Solid particle Print -Page 10 -

Desktop Spectrophotometer (DSCD-910) Basic Introduction DSCD-910 Transmitted liquid Spectrophotometer is good performance and specially designed for testing the liquid transmittance, absorbance, concentration, chrominance and other parameters. The instrument adopts the measurement structure of D/0, integration of the full band LED composite light source, double beam optical system, ETC every-time calibration technology, which makes the instrument reaches a resolution of 0.0001, deviation of the transmittance within 0.08% and chromatic value : E*ab 0.015. DSCD-910 Brief Introduction D\0 Structure It is suitable for testing the glass and liquid color Adopt UV enhanced silicon photodiode Expend the transmittance from 0~100% to 0~200%. -Page 11 -

Pt-Co and Gardner Index- Liquid Yellow Degree Characteristics The unit of Pt-Co is Hazen to show the result. Every liter liquid contains 1mg Platinum with chloroplatinic acid and 2mg cobalt chloride hexahydrate is called one Hazen. Normally, the data is between 1-500. It is suitable for testing transparent liquid or brown liquid whose color similar to one unit Pt-Co calm chroma. Gardner Color Code: Mix the cobalt chloride solution, ferric trichloride solution, potassium chloroplatinate solution in different proportion, we will get the standard color Chroma. Normally, the data is between 1-18. It is suitable for the liquid whose color is darker than Pt-Co color. American Public Health Association (APHA): use K2PtCl6 mix with hydrochloric acid to make the standard color chroma and normally the data is between 1-500 which is same as Hazen. Matching color analysis software Our spectrophotometer comes with the color management software, which is applicable in various industries quality control and management of color data. It turns color into numerical data, compares color differences, generates measurement reports. provides measurement data under different color spaces and customizes color management for each customer. More Product Pictures -Page 12 -

Technical Data Illumination Size of integrating sphere Illumination Light source Sensor DSCD-910 d/0(diffused illumination, 0 viewing)scs optical engine(light splitting and integration system),( conform to CIE No.15, ISO 7724/1, ASTM E1164,DIN 5033 Teil7, JIS Z8722 Condition c standards) Φ40mm,Alvan diffused reflection surface coating CLEDs(entire wavelength balanced LED light source) dual light path sensor array -Page 13 -

DSCD-910 Wavelength range 400-700nm Wavelength interval 10nm Half spectral width 5nm Reflectivity range 0-200% Reflectivity resolution 0.01% Observation angle 2 /10 A,C,D50,D55,D65,D75,F1,F2,F3,F4,F5,F6,F7,F8, Measurement light source F9,F10,F11,F12 CWF,U30,DLF,NBF,TL83,TL84 Transmittance graph/value, chromatic value, color difference values, color assessment results, Data being displayed color tendency, history color value simulation, manual input standard sample, generate measurement reports Measurement time interval 2 seconds Measurement time 0.5 seconds Color space CIE-L*a*b, L*C*h, CIE-L*u*v, XYZ, Yxy, Transmittance, Hunterlab, Munsell MI, CMYK Color difference formulas ΔE*ab,ΔE*CH,ΔE*uv,ΔE*cmc(2:1),ΔE*cmc(1:1 ),ΔE*94,ΔE*00ΔEab(Hunter),555color classification Other colorimetric indices WI(ASTM E313-10,ASTM E313-73,CIE/ISO, AATCC, Hunter, Taube Berger, Ganz, Stensby), YI(ASTM D1925,ASTM E313-00,ASTM E313-73), Tint(ASTM E313-00,CIE,Ganz),Metamerism index Milm, Stick color fastness, Color fastness, APHA, Pt-Co, Gardner Repeatability Interface Data storage Light source longevity Size Weight Work temperature range light splitting reflectivity: standard deviation within 0.08% color values: ΔE*ab<=0.015(After calibration, standard deviation of 30 measurements on test white board, 5 second intervals, Maximum:0.03) USB mass storage 5 years, 1.5 million tests 475*340*150mm(L*W*H) about 7kg 0~45, relative humidity 80% or below( at 35 C ), no condensation -Page 14 -

Storage temperature range Standard accessories DSCD-910 25 to 55,relative humidity 80% or below(at 35 C ), no condensation AC power line, color management software, drive software, USB cable, black calibration tube, 40*10mm cuvette Application Transparent solution Solvent Transparent glass Transparent plastic -Page 15 -

Desktop Spectrophotometer (DSCD-920) ------Compatible with reflection and transmission measurements Basic Introduction Desktop spectrophotometer DSCD-920 has the advantage of excellent inter-instrument agreement, high accuracy and good replicability. It could meet your requirement for both color quality control and color matching very easily. DSCD-920 Brief Introduction Transmission D/0 Structure and Reflection D/8 Structure Double Optical Paths Spectral Analysis Technology It could get the measurement sample data and internal environment data at the same time to make sure the testing accuracy and stability for long time running. Compatible with SCI/SCE Measurement -Page 16 -

Adopt D/8 illuminant condition recommended by the CIE to meet the color testing requirement for different industries. It could measure with SCI and SCE to see the color data change more clearly. Four Testing Calibers It is easy to adjust the testing calibers. The largest caliber diameter reaches 25.4mm. It could test the sample with different sizes. DSCD-920 is not only suitable for testing the color of opacity sample, but also suitable for transparent or translucent sample s transmittance and turbidity. Large screen display and Stand-alone operation It could finish the sample test without connecting with the computer. Large screen display to make sure customer could see the testing result directly and clearly and it will be more convenient to set the instrument status. The color quality management software and color match software are optional according to customer s need. Unique Calibration Board Design Fix the calibration board on the testing caliber to make sure the accuracy of the white calibration and guarantee the high accuracy for measurement. Flexible Test Fixture It could fix the sample with different size and thickness on the testing port tightly in case of stray light entering to affect the testing accuracy. More Product Pictures -Page 17 -

Technical Data Measurement Condition DSCD-920 Reflection: d/8(diffused lighting, 8 degrees receiving)compatible with SCI/SCE Measurement ISO7724/1 DIN5033 Teil7 JIS Z8722 condition C CIE No.15 ASTM E1164)Transmission d/0(diffused lighting, Vertical direction receiving) Size of integrating sphere Φ15.2cm, Alvan diffused reflection surface coating Illumination Light source CLEDs(entire wavelength balanced LED light source) Sensor dual light path sensor array Wavelength range 400-700nm Wavelength interval 10nm Half spectral width 5nm Reflectivity range 0-200% Reflectivity resolution 0.01% Observation angle 2 /10 Measurement light source A,C,D50,D55,D65,D75,F1,F2,F3,F4,F5,F6,F7,F8,F9,F10,F11,F12,CWF,U30,DLF,NBF,TL83,TL84 SPD distribution/data, sample's color values, color difference values/graph, pass/fail results, color Data being displayed error tendency, history data color simulation, manual input standard sample, generate measurement report Measurement time interval 2 seconds Large Aperture (LAV):2.54cm (=1inch) Medium Aperture (MAV):1.5cm(=0.6inch) Reflection Aperture Small Aperture (SAV):0.75cmx1.0cm(0.3inch x 0.4inch) Very Small Aperture(VSAV):0.3cmx0.8cm(0.12inch x 0.31inch) Color space CIE-L*a*b, L*C*h, CIE-L*u*v, XYZ, Yxy, -Page 18 -

Color difference formulas Other colorimetric indices Repeatability Interface Data storage Light source longevity Size Work temperature range Relative Humidity Standard accessories Optional DSCD-920 Transmittance, Hunterlab, Munsell MI,CMYK, RGB, HSB ΔE*ab,ΔE*CH,ΔE*uv,ΔE*cmc(2:1),ΔE*cmc(1:1),Δ E*94,ΔE*00,ΔEab(Hunter),555color classification WI(ASTM E313-10,ASTM E313-73,CIE/ISO,AATCC, Hunter, Taube Berger, Ganz, Stensby), YI(ASTM D1925,ASTM E313-00,ASTM E313-73), Tint (ASTME313-00,CIE,Ganz), Metamerism index Milm, Stick color fastness, Color fastness, APHA, Pt-Co, Gardner light splitting reflectivity: standard deviation within 0.08% color values:δe*ab<=0.015(after calibration, standard deviation of 30 measurements on test white board, 5 second intervals, Maximum:0.03) USB mass storage 5 years, 1.5 million tests 583*330*304mm(L*W*H) 15-32 (60 F-90 F) 0 to 45,relative humidity 80% or below(at 35 C ), no condensation AC power line, color management software, drive software, USB cable, black/white calibration tube, 40*10cuvette, cuvette support, testing report 40x40 cuvette Transparent solution Spin Building material Transparent plastic -Page 19 -