Quantitative analysis and development of a computer-aided system for identification of

Similar documents
Magnified Examination of Small Colorectal Polyps Using a Prototype Electronic Endoscope: Preliminary Experience

Real-Time in vivo Observation of Cells and Nuclei Opens New Possibilities for Diagnostic Endoscopy

Novel Endoscopic Imaging Techniques

Cellular Bioengineering Boot Camp. Image Analysis

Image Extraction using Image Mining Technique

EXpERIENCE THE power Of LIGHT

MINING COLONOSCOPY VIDEOS TO MEASURE QUALITY OF COLONOSCOPIC PROCEDURES

The Trend of Medical Image Work Station

Advancing the Art of Endoscopy

Differentiation of Malignant and Benign Masses on Mammograms Using Radial Local Ternary Pattern

Centre for Computational and Numerical Studies, Institute of Advanced Study in Science and Technology 2. Dept. of Statistics, Gauhati University

Multilayer scanning enhances sensitivity of artificial intelligence-aided Mycobacterium tuberculosis detection

InScape: Making Virtual Pathology a Reality

Fuji Intelligent Chromo Endoscopy

Omnidirectional Vision Attachment for Medical Endoscopes

Towards Optical Biopsies with an Integrated Fibered Confocal Fluorescence Microscope

Advancing the Art of Endoscopy

CHAPTER-4 FRUIT QUALITY GRADATION USING SHAPE, SIZE AND DEFECT ATTRIBUTES

OPTIVISTA TM EPK-i7010

Malignancy Detection of Candidate for Basal Cell Carcinoma Using Image Processing and Artificial Neural Network

GenePix Application Note

Morphologi. Advanced image analysis for high sensitivity particle characterization. Particle size. Particle shape

Segmenting Reddish lesions in Capsule Endoscopy Images Using a GastroIntestinal Color Space

Development of a Robotic Colonoscopic Manipulation System, Using Haptic Feedback Algorithm

ATLAS. Atlas of Spectral Endoscopic Images

endoscope for observing vocal fold

An Image Processing Approach for Screening of Malaria

Computational approach for diagnosis of malaria through classification of malaria parasite from microscopic image of blood smear.

ImageJ: Introduction to Image Analysis 3 May 2012 Jacqui Ross

Observer Performance of Reduced X-Ray Images on Liquid Crystal Displays

USING SIGNATURE IDENTIFICATION FOR RAPID AND EFFECTIVE X-RAY INSPECTION OF BALL GRID ARRAYS

Arcturus XT Laser Capture Microdissection System AutoScanXT Software Module. User Manual

A Method of Using Digital Image Processing for Edge Detection of Red Blood Cells

ENDOSCOPIC ULTRASOUND SYSTEMS

Color Based Stool Region Detection in Colonoscopy Videos for Quality Measurements

Fovea and Optic Disc Detection in Retinal Images with Visible Lesions

3-D Computer-Automated Threshold Amsler Grid Test

AGRICULTURE, LIVESTOCK and FISHERIES

Clinical Natural Language Processing: Unlocking Patient Records for Research

Received on: Accepted on:

Image Analysis for Fluorescence

Analysis and Identification of Rice Granules Using Image Processing and Neural Network

Imaging with hyperspectral sensors: the right design for your application

Single balloon Enteroscope system SIF-Q180 / OBCU

(51) Int Cl.: A61B 1/04 ( )

Automated Detection of Early Lung Cancer and Tuberculosis Based on X- Ray Image Analysis

IMAGING TECHNIQUES FOR MEASURING PARTICLE SIZE SSA AND GSV

Table of Contents 1. Image processing Measurements System Tools...10

Iris Segmentation & Recognition in Unconstrained Environment

ROBOT VISION. Dr.M.Madhavi, MED, MVSREC

COMPONENT II CANDIDATE STUDY GUIDE PEDIATRIC DENTISTRY

A Novel Approach for Automated Color Segmentation of Tuberculosis Bacteria through Region Growing

Digital Retinal Images: Background and Damaged Areas Segmentation

THEORY AND APPROACHES TO AUTOMATED IMAGE ANALYSIS IN DIGITAL PATHOLOGY

Intelligent Traffic Sign Detector: Adaptive Learning Based on Online Gathering of Training Samples

Content Based Image Retrieval Using Color Histogram

Automatic Locating the Centromere on Human Chromosome Pictures

Biometrics Final Project Report

NSERC Summer Project 1 Helping Improve Digital Camera Sensors With Prof. Glenn Chapman (ENSC)

MEASUREMENT CAMERA USER GUIDE

ADVANCED MEDICAL SYSTEMS PTE LTD Singapore Malaysia India Australia

Locating Blood Vessels in Retinal Images by Piece-wise Threshold Probing of a Matched Filter Response

Microwave Measurement and Quantitative Evaluation of Wall Thinning in Metal Pipes

MEASUREMENT OF ROUGHNESS USING IMAGE PROCESSING. J. Ondra Department of Mechanical Technology Military Academy Brno, Brno, Czech Republic

Image Database and Preprocessing

Dynamic Distortion Correction for Endoscopy Systems with Exchangeable Optics

On-site Safety Management Using Image Processing and Fuzzy Inference

Problems and Solutions in Medical Color Imaging

At Fujinon we are committed to delivering innovative endoscopic solutions exactly as envisioned by our customers. Our latest achievement, the Fujinon

Building Damage Mapping of the 2006 Central Java, Indonesia Earthquake Using High-Resolution Satellite Images

Novel 3D Computerized Threshold Amsler Grid Test CA, USA

A new method for segmentation of retinal blood vessels using morphological image processing technique

Urban Feature Classification Technique from RGB Data using Sequential Methods

MATLAB DIGITAL IMAGE/SIGNAL PROCESSING TITLES

1. Queries are issued to the image archive for information about computed tomographic (CT)

Completely Rewrite Industry s Understanding of Transmitting. High Quality Laser Processing Light over Long Distances

Speed Traffic-Sign Recognition Algorithm for Real-Time Driving Assistant System

An Improved Method of Computing Scale-Orientation Signatures

MULTI-PARAMETER ANALYSIS IN EDDY CURRENT INSPECTION OF

2 nd generation TOMOSYNTHESIS

Keywords: - Gaussian Mixture model, Maximum likelihood estimator, Multiresolution analysis

2017 ADVANCING DEEPER INSIGHTS IN ENDOSCOPY

CHAPTER 4 LOCATING THE CENTER OF THE OPTIC DISC AND MACULA

A Solution for Identification of Bird s Nests on Transmission Lines with UAV Patrol. Qinghua Wang

SECTION I - CHAPTER 2 DIGITAL IMAGING PROCESSING CONCEPTS

TR7500 SIII 3D SERIES. AutomAted optical InsPeCtIon

Impact of Endoscopic Image Degradations on LBP based Features using One-Class SVM for Classification of Celiac Disease

About This Survey. General Concepts and Definitions

Student Attendance Monitoring System Via Face Detection and Recognition System

An Essential Health and Biomedical R&D Treaty

BASIC PATTERN RECOGNITION AND DIGITAL IMAGE PROCESSING USING

Digital Pathology at Johns Hopkins Practical Research and Clinical Considerations

Prediction Method of Beef Marbling Standard Number Using Parameters Obtained from Image Analysis for Beef Ribeye

Instruments Commonly Used For Examination of the Eye

Comparison of Segmentation Framework on Digital Microscope Images for Acute Lymphoblastic Leukemia Diagnosis using RGB and HSV Color Spaces

Scanned Image Segmentation and Detection Using MSER Algorithm

Extraction and Recognition of Text From Digital English Comic Image Using Median Filter

Traffic Sign Recognition Senior Project Final Report

UNIT VI. Current approaches to programming are classified as into two major categories:

A Study On Preprocessing A Mammogram Image Using Adaptive Median Filter

Transcription:

Quantitative analysis and development of a computer-aided system for identification of regular pit patterns of colorectal lesions Yoshito Takemura, MD, 1 Shigeto Yoshida, MD, 2 Shinji Tanaka, MD, 2 5 Keiichi Onji, MD, 1 Shiro Oka, MD, 2 Toru Tamaki, PhD, 3 Kazufumi Kaneda, PhD, 3 Masaharu Yoshihara, MD, 4 Kazuaki Chayama, MD 1 1 Department of Medicine and Molecular Science, Graduate School of Biomedical Sciences, Hiroshima University, Hiroshima, Japan 10 2 Department of Endoscopy, Hiroshima University Hospital, Hiroshima, Japan 3 Department of Information Engineering, Graduate School of Engineering, Hiroshima University, Hiroshima, Japan 4 Department of Health Service Center, Hiroshima University, Hiroshima, Japan 15 The work described herein was performed at the Department of Endoscopy, Hiroshima University Hospital, Hiroshima, Japan. Running title: Computer-aided identification of the pit patterns of colorectal lesions 20 Address for correspondence and reprint requests: Shigeto Yoshida, MD, Department of Endoscopy, Hiroshima University Hospital, 1-2-3 Kasumi, Minami-ku, Hiroshima 734-8551, Japan Tel: +81-82-257-5538 Fax: +81-82-257-5538 25 E-mail: yoshida7@hiroshima-u.ac.jp Dr. Takemura 10.023RR

Takemura Y et al, Page 2 ABSTRACT Background: Because pit pattern classification of colorectal lesions is clinically useful in determining treatment options for colorectal tumors but requires extensive training, we 30 developed a computerized system to automatically quantify, and thus classify, pit patterns depicted on magnifying endoscopy images. Objective: To evaluate the utility and limitations of our automated pit pattern classification system. Design: Retrospective study. 35 Setting: Department of endoscopy, university hospital. Main Outcome Measurement: Performance of our automated computer-based system for classification of pit patterns on magnifying endoscopic images in comparison to classification by diagnosis of the 134 regular pit pattern images by an endoscopist. Results: For types I and II pit patterns, the results of discriminant analysis were in complete 40 agreement with the endoscopic diagnoses. For type IIIL, out of 30 cases, 29 (96.7%) were diagnosed as type IIIL and 1 as type IV. For type IV, 29 out of 30 cases (96.7%) were diagnosed as type IV pit pattern. Overall accuracy of our computerized recognition system was 132/134 (98.5%). Conclusions: Our system is best characterized as semi-automated but a step toward 45 development of a fully automated system to assist in the diagnosis of colorectal lesions based upon classification of pit patterns. Word count: 195 Key words: Computer-aided recognition; pit pattern 50

Takemura Y et al, Page 3 INTRODUCTION Magnifying endoscopy permits detailed visualization of the surface of the gastrointestinal tract and thus allows examination of the pit pattern (shape of the openings of 55 colorectal crypts) of colorectal tumors (Figure 1). 1 Pit pattern classification has been shown to aid in the differentiation of non-neoplastic and neoplastic colorectal lesions 2 and thus may be able to guide therapeutic decisions. Magnifying endoscopy with pit pattern recognition can be done during routine colonoscopy with indigo carmine dye spraying or crystal violet staining with little added expense or time. We have been interested in developing a software program 60 that can analyze pit patterns quantitatively and thus be used with magnifying endoscopy to diagnose colorectal tumors. We created a custom software program for this very purpose and herein describe its development and an experimental study in which we tested its clinical utility and limitations. 65 METHODS Image analysis software We developed a custom software program (HuPAS ver. 1.3) that can outline various regular pits identified on digitized endoscopic images. HuPAS is designed to mark the color 70 edges of a pit outline based on differences in color tone between the pit outline and the background; it then automatically extracts the identified pits. The software identifies regional segmentation using a watershed algorithm and combines integrated regions with excessive segmentation. 3 75 Endoscopic procedure The HuPAS image analysis software was tested on magnifying endoscopy images obtained from patients who had undergone diagnostic endoscopic study at Hiroshima University

Takemura Y et al, Page 4 Hospital. An Olympus CF-H260AZI magnifying colonoscope (Olympus Co., Tokyo, Japan) was used, which provides magnification up to 70 (optical magnification) on a 19-inch monitor. 80 After performing white light endoscopy, we examined the lesion at maximum magnification with crystal violet staining. Thereafter, images were digitized and stored on an Olympus EICP-D HDTV recorder (1,440 1,080 pixels). Informed consent was obtained from patients and/or family members for endoscopic examination. 85 Image processing Pit region extraction From each magnified endoscopic image recorded at maximum optical magnification (Figure 2a), a 250 250-pixel region was cut out as a region of interest (ROI) (Figure 2b). The cut-out image was processed automatically by using the custom HuPAS ver. 1.3 software to 90 outline various pits identified on the digitized image (Figure 2c). The computer operator (S.Y.) removed non-pit regions and/or joined excessively segmented pit regions manually if necessary using Adobe Photoshop (Adobe Systems Inc. San Jose, CA) (Figure 3). Quantification of pit features 95 Using ImageJ software (National Institutes of Health, Bethesda, MD), we quantified the following six shape descriptors for each pit on the extracted images: area, perimeter, major and minor axes of the best fit ellipse, circularity (represented as 4π(area/perimeter 2 )), wherein 1.0 = a precise circle that becomes an elongated polygon as it approaches 0.0), and Feret s diameter (longest distance between any two points within the selected frame) (Figure 4). These six shape 100 descriptors were chosen for quantification because statistical analysis (Kruskal-Wallis test) revealed that differences in the values of these descriptors between types of regular pit patterns (Kudo and Tsuruta classes si, sii, siiil, siiis, siv) were significant. Quantitative analysis of regular pit patterns

Takemura Y et al, Page 5 105 Feature extraction and quantification of the regular pit Colorectal magnifying endoscopy was performed in 72 cases at Hiroshima University Hospital between June 2007 and September 2007. Images of regular pits were obtained from the magnified endoscopic images (type I: 20 cases; type II: 10 cases; type IIIL: 10 cases; type IIIs: 2 cases; and type IV: 30 cases) as a set of training images. After extracting the pit region of the 110 ROI using HuPAS, an endoscopist (Y.T.) selected separate images of regular pits based on the morphology of the opening of the colorectal crypt and classified each pit, according to the Kudo and Tsuruta classification system (Figure 3b), as type si (round), type sii (asteroid), type siiil (larger than type si, ranging from tubular to round), type siiis (smaller than type si, ranging from tubular to round), or type siv (dendritic or gyrus-like). Based on the image processing 115 described above, quantitative features were defined for each pit type. Computer-aided identification of regular pit patterns A set of validation images was gathered from among images obtained in other cases examined at Hiroshima University Hospital. We excluded lesions that were not 120 suitable for evaluation (exclusion criteria: out-of-focus images, images that showed insufficient staining, images that were blurred). A total of 134 regular pit pattern images (type I: 32 cases; type II: 43 cases; type IIIL: 29 cases; and type IV: 30 cases) were sequentially obtained and comprised the validation set. After the separate pit types were determined based on the imaging processing described above, a discriminant analysis using JMP statistical software (SAS 125 Institute Inc. Cary, NC) was conducted by referring to the quantitative characteristics of the set of training images for automated recognition of pit patterns on the endoscopic images. Discriminant analysis is used for estimating the population to which sample data belong when the population in which the sample data reside is unknown. Thus, we first obtained quantitative characteristics for each pit type as reference data and then conducted discriminant analysis for 130 each pit based on these data. Together with the subsequent step of weighing the proportion of each pit within the respective images, we defined these steps as the two steps required to

Takemura Y et al, Page 6 definitively identify the patterns of the pits identified on endoscopic images. In addition, the pit patterns on the validation images were classified according to the Kudo and Tsuruta system by the same endoscopist (Y.T.), who was blinded to the computer-aided results. 135 Statistical analysis Values are reported as mean ± SD. Differences in the six quantitative features (shape descriptors) between the various pit patterns were analyzed by Kruskal-Wallis test, with significance accepted at P < 0.05. 140 RESULTS Quantification of the regular pit patterns Values for each of the six shape descriptors are shown per pit pattern in Table 1. For 145 each of the six features, differences in values between the five regular pit patterns were significant. Automated identification of regular pit patterns Performance of the automated computer-aided system for pit pattern classification of 150 colorectal lesions is shown relative to endoscopy findings in Table 2. Overall accuracy of the automated computer-aided system for identification of regular pit patterns was 132/134 (98.5%). DISCUSSION 155 To our knowledge, there are no reports of computerized quantitative analysis of pit patterns of the colorectal mucosal surface. Computerized quantification of the pit pattern of a

Takemura Y et al, Page 7 colorectal lesion should allow for objective diagnosis, avoiding subjectivity and eliminating the need for extensive training in evaluating pit patterns. 160 We developed a software program, known as HuPAS, that can be used to outline and characterize various pits in the colonic mucosa on endoscopically obtained images. We found that values for six shape descriptors differed significantly between regular separate pit patterns (types si-siv), so these shape descriptors became the basis for our quantitative analysis. We also analyzed the accuracy of the automated computerized identification of the pit 165 patterns in reference to endoscopic diagnosis. The overall diagnostic accuracy of the computer-aided diagnosis based on automated calculation of the pit area was 98.5%. Thus, the custom software and computer-aided diagnosis algorithm together approached the diagnostic ability of the trained endoscopist. Our automated system is limited in that some non-pit regions are extracted with the pit regions and 170 some pit regions are excessively segmented. This is because some non-pit regions differ in color tone from the background and some pit regions are of low contrast. Thus, it was necessary to remove these non-pit regions and/or join excessively segmented pit regions using Adobe Photoshop in 11% of cases. This procedure does not make the process subjective, but it does add a manual step. In addition, endoscopic images that were out-of-focus, that showed insufficient staining, or that were blurred could not be 175 evaluated. It might be possible to overcome these limitations by adding another algorithm. Unfortunately, our computer analysis takes several minutes, so the results are not available during colonoscopic examination. Improvements are needed that will allow real-time computerized evaluation of the pit patterns of colorectal lesions. If rapid, accurate differentiation between neoplastic and non-neoplastic polyps can be made by magnification endoscopy with computer-aided diagnosis, this technique could 180 reduce the number of polypectomies required and also reduce complications. We succeeded in developing a computerized system for automated recognition of regular pit patterns on magnified endoscopy images. With its limitations, our system is perhaps best characterized as semi-automated but a step toward development of a fully automated system to assist in the diagnosis of colorectal lesions. We anticipate development of a fully

Takemura Y et al, Page 8 185 automated system that will recognize both regular and irregular pit patterns and will meet the rigors of blinded prospective evaluation comparing the results of computerized analysis against pathologic classification as the gold standard.

Takemura Y et al, Page 9 REFERENCES 190 1. Tanaka S, Kaltenbach T, Chayama K, et al. High-magnification colonoscopy (with videos). Gastrointest Endosc 2006;64:604-13. 2. Fu KI, Sano Y, Fujii T, et al. Chromoendoscopy using indigo carmine dye spraying with magnifying observation is the most reliable method for differential diagnosis between non-neoplastic and 195 neoplastic colorectal lesions: a prospective study. Endoscopy 2004;36:1089-93. 3. Hirota M, Tamaki T, Kaneda K, et al. Feature extraction from images of endoscopic large intestine. Proceedings of FCV2008; The 14th Korea-Japan Joint Workshop on Frontiers of Computer Vision 2008;01:94-9. 200

Takemura Y et al, Page 10 Figure Legends Figure 1. Classification of pit patterns of colorectal lesions. 205 Figure 2. Pits are outlined on the magnified endoscopic images with the use of our custom HuPAS ver.1.3 software. a: Observation and recording of the stained (crystal violet) image at maximum optical magnification (x70). b: A region of interest (ROI) measuring 250 250 pixels is cut out for analysis. c: Example of a pit region automatically extracted by HuPAS. 210 Figure 3. Extracted images of pit outlines within the region of interest. a: Original image of a pit region automatically extracted by HuPAS. b: The image generated by HuPAS required some Adobe Photoshop editing. The separate pit images (si, sii, siiis, siiil, siv) (arrows) were classified according to the Kudo and Tsuruta criteria. 215 Figure 4. Diagram of the six shape descriptors used for quantitative analysis of pit patterns. (1) area, (2) perimeter, (3) major axis of the best fit ellipse, (4) minor axis of the best fit ellipse, (5) circularity: 4 (area/perimeter 2 ), wherein1.0 = precise circle that becomes an elongated polygon as it approaches 0.0, and (6) Feret s diameter, which is the longest distance between any two points within the selected frame. 220

Type I Round pit (normal pit) non-neoplastic Type II Asteroid pit non-neoplastic Type IIIS Tubular or round pit that is smaller than the normal pit (Type I) neoplastic Type IIIL Tubular or round pit that is larger than the normal pit (Type I) neoplastic Type IV Dendritic or gyrus-like pit neoplastic Type VI Irregular arrangement and sizes of IIIL, IIIS, IV type pit pattern neoplastic Type VN Loss or decrease of pits with an amorphous structure neoplastic Figure 1. Classification of pit patterns of colorectal lesions. Figure 1, Takemura et al

Figure 2, Takemura et al Figure 2 a b c

Figure 3, Takemura et al Figure 3 stype I stype II stype IIIL stype IV a b

Figure 4 Figure 4, Takemura et al Quantitative characteristics for six examined items Minor Fit Ellipse Feret s Diameter Major Fit Ellipse Area Perimeter Major Fit Ellipse Minor Fit Ellipse Circularity: 4π(area/perimeter 2 ) (1.0=precise circle; becomes an elongated polygon as it approaches 0.0) Feret s Diameter: longest distance between any two points within the selected frame.

Table 1. Quantitative analysis of regular pit patterns Pit pattern Number of pits Area Perimeter Major fit ellipse Minor fit ellipse Circularity Feret s diameter Type si 453 44.0±24.5 26.1±8.3 9.3±2.9 5.7±1.6 0.78±0.12 10.4±3.1 Type sii 210 195±134 101.0±58.3 23.4±8.0 9.9±4.5 0.29±0.15 32.1±13.6 Type siiil 268 226±155 118.7±65.8 40.2±18.5 6.7±2.3 0.24±0.13 49.2±26.5 Type siiis 26 5.4±3.4 7.93 ±3.00 3.16 ±1.09 2.03 ±0.67 0.93 ±0.12 3.61 ±1.14 Type siv 268 749±455 354±203 56.3±18.9 17.4±8.9 0.097±0.067 109.1±42.5 P<0.0001 P<0.0001 P<0.0001 P<0.0001 P<0.0001 P<0.0001 Data are mean±sd. P values were obtained by Kruskal-Wallis test, which was used to analyze between-pattern differences in the values of each of the six features.

Table 2. Performance of the semi-automated CAD algorithm for pit pattern classification of colorectal lesions Classification using the CAD software Endoscopic diagnosis Type I Type II Type IIIL Type IV Total Type I 32 (100) 0 0 0 32/32 (100) Type II 0 43 (100) 0 0 43/43 (100) Type IIIL 0 0 28 (96.6) 1 (3.4) 28/29 (96.6) Type IV 0 0 1 (3.3) 29 (96.7) 29/30 (96.7) Data are number (percentage) of lesions. Overall accuracy: 132/134 (98.5%) CAD : computer-aided diagnosis