Round or Square Type IC Wall Wash Housing with Lamp for Flangeless Trims

Similar documents
Round or Square Type IC Down Light Housing with LED Lamp for Flangeless Trims E3_L_-L_DI 1.4

Round or Square Chicago Plenum Down Light Housing with Lamp

with Lamp Install the Housing with Adjustable Bars Installation Instructions for LED E3_-L_DN 1.1 ½ to ¾ ¾ or thicker

Install the Housing. Installation Instructions for Entra Round or Square Type IC, Air-tight New Construction Adjustable LED Housing EN3_-LH9_ 1.

Multiples EM_ 1.4. Install 1X1/1X2/1X3/1X4 Housings. Installation Instructions for. This product is suitable for indoor locations.

Reflections Housing with EldoLED and Lutron Hi-lume Drivers EDIHE_ 1.4

Prepare the Fixture. Sage 37 Bath. Back Plate Installation (Horizontal) Installation Instructions for 700BCSAGW37_

Micro Channel. Shorten the Fixture (optional) Installation Instructions for 700UMCD_ UNILUME. This product is suitable for damp locations.

Installation Instructions For Aurora Dual MR16 Round & Square Edge 3.3" Fig.1 Complete Fixture ADJUSTABLE GEARS HIDDEN BEHIND THE LAMP PAN LOCK

INSTALLATION: D1-NOTCH DRYWALL TRIM FLANGE

DOWNLIGHT LED SERIES INSTALLATION INSTRUCTIONS

Installation Instructions For Aurora Halogen Accent Housing 3 Round & Square Trimless AH1-ARE, AH1-ARB, AH1-ASE, AH1-ASB. Fig.

Installation and Assembly: Articulating Swivel Arm for 37" - 60" Flat Panel Displays

INSTALLATION INSTRUCTIONS FOR FLUSH MOUNT FIXTURES

LIGHT FIXTURES MUST BE COMPLETELY INSTALLED PRIOR TO CEILING CONSTRUCTION

Installation and Assembly - Universal Articulating Swivel Double-Arm for 42" - 60" Plasma Screens

+ - 1a. 1b. c. 1d. 1e. Runway Suspended / Surface Cont. Run Installation. 2.0mm DIL DIL Revision - M 23/11/2018 Page 1

INSTALLATION INSTRUCTION Silo Multiples - New Construction Housing MT-4*15, MT-4*10

General Installation Instructions

INSTALLATION INSTRUCTIONS FOR FLUSH MOUNT FIXTURES

Installation Instructions For Aurora Halogen Accent Housing 3 Round & Square Trimless AH2-ARE3 & AH2-ASE3. Fig.1 Complete Fixture

This specification grade LED downlight offers a wide selection of LED module options to address design requirements in the spaces it illuminates.

General Installation Instructions LED

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS Xenix Incandescent Series XN12, XN24, XN36, XN48

INSTALLATION INSTRUCTIONS REPLACING EXISTING DEADBOLT ASSEMBLY

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

3" LED SPECIFICATIONS REMODEL FIXED DOWNLIGHT

INSTALLATION INSTRUCTIONS

Installing Fixture Using Remote Power Supply

EXPLODED VIEW AND PART CALL OUT ASSEMBLING THE METALUX DF SERIES FRAME KIT

Installation Instructions For Aurora Halogen Accent Housing 3 Round & Square Trimless AH2-ARE3 & AH2-ASE3. Fig.1 Complete Fixture

INDIVIDUAL MOUNTING: T-Bar

Installation and Assembly: In-wall Mount for 32" to 71" Flat Panel Displays

2. Connect driver to power source leads. After connections are made, place driver above ceiling. SEE MINIMUM SPACE REQUIREMENTS BELOW.

Installation and Assembly - Universal Articulating Swivel Double-Arm for 42" - 60" Plasma Screens

AURORA HALOGEN ACCENT HOUSING 3 ROUND AND SQUARE TRIMLESS AH3-ARE3-RBG & AH3-ASE3-RGB INSTALLATION INSTRUCTIONS

THIS SHEET CONTAINS IMPORTANT SAFETY INSTRUCTIONS. SAVE THESE INSTRUCTIONS.

LINESSE LINEAR LUMINAIRE 3 RECESSED CV2424

Figure A. Figure B. Figure C. Figure D

C 0.05" ALLEN WRENCH. Installation Instructions for Cirrus Channel Suspension T1 with 4" Square or Round Canopy. Section One: Adjusting Cable Position

SeriesTWO RGB Fluorescent Fixtures. Installation and Instruction Manual

LED RECESSED ADJUSTABLE 3-1/4 APERTURE Non-IC Rated, 1000 LUMEN TC49L, TC949L

Interra Installation Manual

Installation Instructions for TruLine 1.6A 24VDC. Section One: Basic Configuration Options

MantelMount. TM1A Installation Instructions IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS

Inde-Pendants Family. 32L Surface Mount Cylinder with Ring Plaster Trim, Grid and Drywall Ceiling Types. Document No

UTILIBAY UTB2 HIGH BAY WARNINGS

MM540 Installation Instructions IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS

Power Vault Adapter. Install the Power Vault Adapter to MonoRail Power Feed Canopies & Recessed Can Transformer. Installation Instructions for

P /8 Ring Diameter 90. Trim Ring Mounting Holes P /8. 393/16 Ring Diameter. Stud Minimum

Inde-Pendants Family. 32L Ring Plaster Trim, Grid and Drywall Ceiling Types. Document No Installation instructions for 32L-Rxx-P

Installation Instructions For TruLine 1.6A 24VDC

INSTALLATION INSTRUCTIONS IMPORTANT SAFEGUARDS SAVE THESE INSTRUCTIONS INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS FOR INSTALLING T-SERIES EXTRA HEAVY DUTY LEVER LOCKSET

Installation Instructions for Cirrus Suspension Downlight with Power - End Feed. Section One: 4" Flush Canopy Version

SM-RAZOR-T-M/L/XL. Strong Low Profile Tilt Mount for Ultra-Thin Flat-Panel TVs INSTRUCTION MANUAL

Installation and Assembly: Projector Ceiling/Wall Mount

Joiner Kit Joiner bracket (x1) Biscuit aligners (x2) Trim Flange

OB1U INSTALLATION INSTRUCTIONS. Interactive Flat Panel Over White Board Mount

HP 2 SERIES Integral Driver - Solid State LED

Installation Instructions for DIY or Completed 45 Degree Light Channel

FIXTURE INSTALLATION GUIDE Model T21T (Low Voltage Pendant Set 120V)

ADAPT. ABILITY. X 6.50" Example of a continuous row. Shown: hanging the fixture via threaded rods.

NOVA-EXT Versatile Projector Mount Model: NOVA-EXT

Assembly Instructions for Model: VMPR1

Connecting the Channel A

Vertical Honeycomb Shades

Installation and Assembly - Articulating Swivel Double-Arm for 42" - 71" Plasma Screens

Installation Instructions for TruLine 1A Center Feed Power Channel Connector

INSTALLATION INSTRUCTIONS

EOS LED Surface Mounted Luminaire

Installation Instructions for Zip Suspension Downlight with Remote Power and 4" Square or Round Canopy

INSTALLATION INSTRUCTIONS

Installation and Assembly: Flat Panel Pull-out Swivel Wall Mount

PAM-200 Universal Projector Mount

B235 Mobius Sconce Page 1 of 6

Installation Instruction

EOS Direct/Indirect LED Pendant Luminaire

7878 K940. Checkpoint Antenna. Kit Instructions. Issue B

ABM International, Inc. Navigator Assembly Manual

Line volt rail & fixtures. Low volt quick connect fixtures with transformers

INSTALLATION INSTRUCTIONS

MM340 Installation Instructions IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS

Installation and Assembly: In-wall Mount for 32" to 71" Flat Panel Screens

SM-RAZOR-F-M/L/XL. Strong Low Profile Fixed Mount for Ultra-Thin Flat-Panel TVs INSTALLATION MANUAL

Installing flat panels on the MPL15 wall mount

TIP FOR GETTING STARTED

Ceiling Tile Installations Part 1. Sheetrock Installations Part 2. WolfVision Support 2055 Sugarloaf Circle, Suite 125 Duluth, GA 30097

Installation and Assembly: Flat Video Wall Mount For 40" to 65" Flat Panel Displays

IBM xseries 345 Third Party Slide Rail Kit

MaxLite Linear Strip ECO Series

Installation Instructions

Inigo Sconce INSTALLATION INSTRUCTIONS P _2_A 1 of 5

INSTALLATION RECOMMENDATIONS For The Con-Tech ODYSSEY Line Voltage Flexible Track System

Direct Burial Floodlight - DBF Installation Instructions Above Grade Housing

3% VOLTAGE DROP. Installation Instructions for 400 Watt 24 Volt DC RGB DMX LED Power Supply SAVE THESE INSTRUCTIONS!

Wiring Techniques for Wiring a Lamp

INSTALLATION INSTRUCTIONS FIXTURE SERIES: SAE 202 MOUNTING TYPE: RECESSED WALL / SLOT PAGE: 1 OF 8

Transcription:

Installation Instructions for 90ELED-WIC Round or Square Type IC Wall Wash Housing with Lamp for Flangeless Trims LED E_L_-L_WI. LED - ROUND/ SQUARE FLANGELESS GENERAL PRODUCT I NFORMATION: This product is suitable for indoor locations. This product can be dimmed with a standard electronic dimmer. This instruction shows a typical installation. CAUTION - RISK OF FIRE This product must be installed in accordance with the applicable installation code by a person familiar with the construction and operation of the product and the hazards involved. Use minimum 90 c supply conductors. Install the Housing with Adjustable Bars A B HOUSING NAIL ½ to ¾ LEAVE TAB IN PLACE ¾ or thicker NOTE: Skip this section if installing the housing with butterfly brackets. BREAK OFF AND DISCARD OUTER ADJUSTABLE BAR INNER ADJUSTABLE BAR HOUSING CLASP STOP POINT Keep Tab for ceiling ½ to ¾ thick. When using adjustable hanger bars with ½ to ¾ thick ceilings, leave the tab of the hanger bars in place. Break off Tab for ceiling ¾ or thicker. When using adjustable hanger bars with ¾ or thicker ceilings, remove the tab by bending it at the perforation. TAB Slide the inner adjustable bar completely through the three housing clasps. Make sure the nail is on top. Slide and push the outer adjustable bar completely onto the inner adjustable bar so that the tab clicks into place behind the stop point.this will prevent the adjustable bars from coming apart. Repeat steps & for the other side of the housing.

C JOIST D NAIL HOUSING NOTCH ADJUSTABLE BAR NOTE: The adjustable bars can be mounted to joists that are spaced " - " apart. Align the bottom of the end plates with the bottom of the ceiling joists. Level the adjustable bars and, with a hammer, tap the nails completely into the joists to secure the adjustable bars in place. HOUSING NOTCH Adjust the trim holder position (horizontal position) by sliding the housing on adjustable bars. When the desired location is achieved, tighten the two # self tapping screws to lock the housing onto the adjustable bars. NOTE: Notches in trim holder can be used to align multiple housings using a laser or string.

Install the Housing with Butterfly Brackets Connect Power to the Housing A NOTCH A TAB ELECTRICAL BOX COVER BUTTERFLY BRACKET WING NUT NOTE: Skip this section if installing the housing with adjustable bars. Push the tab on the housing electrical box up and remove the electrical box cover. Slightly loosen the wing nut to slide the butterfly bracket up or down. After achieving the proper location, tighten the wing nut to secure the butterfly bracket in place. Repeat steps and on for the other butterfly bracket. B CONDUIT Utilize the butterfly brackets to install the housing in accordance with local electrical codes. NOTE: Notches in trim holder can be used to align multiple housings using a laser or string. Install the conduit to the housing electrical box. Run the power line wires into the housing electrical box. WARNING: RISK OF FIRE: When using the housing electrical box for power feed through, use MAX - # AWG, or - # AWG branch circuit wires.

Install Drywall and Plaster Ring C A -/" -/" ROUND SQUARE Connect the neutral power line wire to the white transformer wire with a wire nut. Connect the hot power line wire to the black transformer wire with a wire nut. For round trims, mark a -/" diameter circle on drywall. Cut out the marked section. For square trims, mark a -/" square on drywall. Cut out the marked section. Make sure that housing is grounded in accordance with local electrical codes. B Replace the electrical box cover. Make sure that the top edge of the cover snaps under the tab. DRYWALL JOIST Align the cut out section of drywall with the trim holder and install drywall.

C TAB TAB D #- SCREW #- SCREW LOCK LOCK ROUND PLASTER RING SQUARE PLASTER RING Secure the plaster ring in place with the two provided flat head #- screws. Make sure that the screws penetrate through the drywall into the housing screw holes. NOTE: Do not overtighten the screws! Overtightening may bend the plaster ring, causing the plaster surface to come away from the drywall. E CUT OUT CUT OUT LOCK LOCK Line up the two tabs in back of the plaster ring with the two cut out sections of the trim holder inside edge. Push the plaster ring tabs into the cut out sections of the trim holder edge. Plug the trim holder with the provided dust shield. Properly plaster onto the plaster ring and drywall. F LOCK LOCK Finish around the trim to match drywall.

Replacing the Lamp A Adjust the Lamp Housing A C AUTION:To reduce the risk of a burn or electric shock during relamping, disconnect the power to the fixture. Remove the trim from the fixture. Loosen all three screws from the lamp assembly and pull the LED lamp out. B FRONT COVER LAMP Ensure that the lens assembly is centered to the aperture by pulling the assembly to the center of the housing.when centered the locking pin will be engaged. B ROTATION LOCK NOTE: Lamp housing can rotate horizontally. Use ONLY WATT proprietary Element Lighting LED lamp. Pull the rotation lock down to unlock the lamp housing. Line up the square and round pegs in the new lamp with the holes in the heatsink and push the new lamp into place. Rotate the lamp housing horizontally. When the desired position is achieved push the rotation lock up to lock the lamp housing in place. Replace the front cover. Reinstall the trim. NOTE: If installing optional lenses, see page for instructions before reinstalling the lamp assembly.

Install the Lenses (Optional) A C ES HOLDER Place lenses (max., optional) inside the lens holder. B Line up the legs of the lens holder with the notches on the lamp holder and push the lens holder on. Vertical Alignment Guides Horizontal Alignment Guides Use the lens orientation guides to align linear spread lenses vertically or horizontally.

STATEMENT OF WARRANTY Tech Lighting warrants all products manufactured by Tech Lighting to be free from defects in material and workmanship under normal use for a specified period after the date of original purchase as follows: years for LED products; years for Energy Star qualified products; year for all other products. For details, visit our website at: www.techlighting.com/aboutus#warranty SAVE THESE INSTRUCTIONS! 00 Linder Ave. Skokie, IL 00.0.00 www.element-lighting.com 0 Tech Lighting, L.L.C. All rights reserved.the "Element" graphic is a registered trademark of Element. Element reserves the right to change specifications for product improvements without notification.